INKEL Limited has published Construction Of New Hospital Block At District Hospital , Mavelikkara ( Sh- Civil Works , Mep Works And Associated Utilities ) . Submission Date for this Tender is 17-06-2020. Building Work Tenders in District Hospital, Mavelikkara Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 31-Mar-2020 | Corrigendum8 | Date | 20-04-2020 |
2 | 17-Apr-2020 | Corrigendum 9 | Date | 11-05-2020 |
3 | 05-May-2020 | CORRIGENDUM No. 10 | Date | 23-05-2020 |
4 | 19-May-2020 | CORRIGENDUM No. 11 | Date | 06-06-2020 |
5 | 03-Jun-2020 | Corrigendum No. 13 | Other | 10-06-2020 |
6 | 10-Jun-2020 | Corrigendum No.14 | Date | 17-06-2020 |
Work Name : Construction of New Hospital Block at District Hospital, Mavelikkara (SH: Civil Works, MEP Works and Associated Utilities) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Sub Head -Pile Foundation | BI01010001010000000000000515BI0100001113 | ||
2 | 1.01 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-35 (Cement quantity -400kg/m3) of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).Note:Truck mounted/Rotary/TMR/Tubewell boring machine shall not be used. (Min cement content is 400kg/cum and no payment shall be made for extra cement.) 600 mm dia piles | BI01010001010000000000000515BI0100001114 | 714 | metre |
3 | 1.02 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-35 (Cement quantity -400kg/m3) of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).Note:Truck mounted/Rotary/TMR/Tubewell boring machine shall not be used.(Min cement content is 400kg/cum and no payment shall be made for extra cement.) 750 mm dia piles | BI01010001010000000000000515BI0100001115 | 18018 | metre |
4 | 1.03 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityInitial test | BI01010001010000000000000515BI0100001116 | 1 | per test |
5 | 1.04 | Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine test | BI01010001010000000000000515BI0100001117 | 1 | per test |
6 | 1.05 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Initial test up to 150 tonne capacity | BI01010001010000000000000515BI0100001118 | 1 | each |
7 | 1.06 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge.routine test up to 150 tonnes | BI01010001010000000000000515BI0100001119 | 9 | each |
8 | 2 | Sub Head- Earth Work | BI01010001010000000000000515BI0100001120 | ||
9 | 2.01 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | BI01010001010000000000000515BI0100001121 | 6130 | cum |
10 | 2.02 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | BI01010001010000000000000515BI0100001122 | 2035 | cum |
11 | 2.03 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | BI01010001010000000000000515BI0100001123 | 140 | cum |
12 | 2.04 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | BI01010001010000000000000515BI0100001124 | 5235 | cum |
13 | 2.05 | Extra for every additional lead of 50 m or part there of for disposal of excavated earth and stacking | BI01010001010000000000000515BI0100001125 | 1400 | cum |
14 | 2.06 | Extra for every additional lead beyond 50m upto 1Km (within the hospital compound) for disposal of excavated earth & stacking. | BI01010001010000000000000515BI0100001126 | 1200 | cum |
15 | 2.07 | Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge | BI01010001010000000000000515BI0100001127 | 75 | cum |
16 | 2.08 | Supplying and packing 20mm stone aggregate between the retaining wall and earth fill along the building perimeter including watering, ramming, consolidating and dressing complete including lead, lift, stacking, transportation etc. as directed by the Engineer in charge - for retaining wall | BI01010001010000000000000515BI0100001128 | 130 | cum |
17 | 2.09 | Providing & applying two compound coal tar epoxy protection (brush application) after cleaning the surface -minimum 200 micron DFT-For retaining walls. | BI01010001010000000000000515BI0100001129 | 850 | sqm |
18 | 2.1 | Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 3 m but not exceeding 4.5 m | BI01010001010000000000000515BI0100001130 | 205 | sqm |
19 | 2.11 | Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete (Measurements to be taken of the face area timbered).Depth exceeding 3 m but not exceeding 4.5 m | BI01010001010000000000000515BI0100001131 | 307 | sqm |
20 | 2.12 | Bailing out water using pump above 5 HP and Up to 10 HP-Bailing out water with engine and pump set above 5HP and up to 10HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete | BI01010001010000000000000515BI0100001132 | 240 | hour |
21 | 3 | Sub Head -plain cement concrete works | BI01010001010000000000000515BI0100001133 | ||
22 | 3.01 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001134 | 230 | cum |
23 | 3.02 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001135 | 323 | cum |
24 | 4 | Sub Head - Reinforced cement concrete | BI01010001010000000000000515BI0100001136 | ||
25 | 4.01 | Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Min cement content is 350kg/cum and no payment shall be made for extra cement).All work upto plinth level. | BI01010001010000000000000515BI0100001137 | 3119 | cum |
26 | 4.02 | Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Min cement content is 340kg/cum and no payment shall be made for extra cement).All work above plinth level upto floor V level | BI01010001010000000000000515BI0100001138 | 7428 | cum |
27 | 4.03 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001139 | 184 | cum |
28 | 4.04 | Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof. | BI01010001010000000000000515BI0100001140 | 2984 | cum |
29 | 4.05 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001141 | 11 | cum |
30 | 4.06 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | BI01010001010000000000000515BI0100001142 | 3255 | sqm |
31 | 4.07 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | BI01010001010000000000000515BI0100001143 | 5840 | sqm |
32 | 4.08 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001144 | 24135 | sqm |
33 | 4.09 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | BI01010001010000000000000515BI0100001145 | 17620 | sqm |
34 | 4.1 | Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | BI01010001010000000000000515BI0100001146 | 8710 | sqm |
35 | 4.11 | Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) | BI01010001010000000000000515BI0100001147 | 776 | sqm |
36 | 4.12 | Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards | BI01010001010000000000000515BI0100001148 | 100 | sqm |
37 | 4.13 | Extra for shuttering in circular work (20% of respective centering and shuttering items) | BI01010001010000000000000515BI0100001149 | 25 | sqm |
38 | 4.14 | Centering and shuttering including strutting, etc. and removal of form for:Cornices and mouldings. | BI01010001010000000000000515BI0100001150 | 150 | sqm |
39 | 4.15 | Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges | BI01010001010000000000000515BI0100001151 | 1596 | sqm |
40 | 4.16 | Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) | BI01010001010000000000000515BI0100001152 | 18345 | sqm |
41 | 4.17 | Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001153 | 10 | cum |
42 | 4.18 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete at all levels. Thermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001154 | 1.92861e+06 | kilogram |
43 | 5 | Sub Head- Block Work | BI01010001010000000000000515BI0100001155 | ||
44 | 5.01 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete | BI01010001010000000000000515BI0100001156 | 80 | cum |
45 | 5.02 | Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means. | BI01010001010000000000000515BI0100001157 | 1690 | cum |
46 | 5.03 | Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001158 | 75 | cum |
47 | 5.04 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001159 | 85 | cum |
48 | 5.05 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete | BI01010001010000000000000515BI0100001160 | 43 | cum |
49 | 5.06 | Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | BI01010001010000000000000515BI0100001161 | 2045 | cum |
50 | 5.07 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete | BI01010001010000000000000515BI0100001162 | 2190 | cum |
51 | 6 | Joinery Works | BI01010001010000000000000515BI0100001163 | ||
52 | 6.01 | Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account). | BI01010001010000000000000515BI0100001164 | 8785 | kg |
53 | 6.02 | Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing (with open joints) for linear as well ascurvilinear portions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings. (Refer Part C for more details) | BI01010001010000000000000515BI0100001165 | 1225 | sqm |
54 | 6.03 | Extra for openable side / top hung vision glass panels (IGUs) including providingand supplying at site all accessories and hardwares for the openable panels asspecified and of the approved make such as heavy duty stainless steel frictionhinges, min 4 -point cremone locking sets with stainless steel plates, handles,buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts,washers etc. all complete as per the Architectural drawings, as per the approvedshop drawings, as specified and as directed by the Engineer-in-Charge. | BI01010001010000000000000515BI0100001166 | 7 | sqm |
55 | 6.04 | Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge."For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. | BI01010001010000000000000515BI0100001167 | 650 | sqm |
56 | 6.05 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) | BI01010001010000000000000515BI0100001168 | 25924 | kg |
57 | 6.06 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) | BI01010001010000000000000515BI0100001169 | 19011 | kg |
58 | 6.07 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides | BI01010001010000000000000515BI0100001170 | 616 | sqm |
59 | 6.08 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness | BI01010001010000000000000515BI0100001171 | 751 | sqm |
60 | 6.09 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness | BI01010001010000000000000515BI0100001172 | 363 | sqm |
61 | 6.1 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness | BI01010001010000000000000515BI0100001173 | 305 | each |
62 | 6.11 | Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm | BI01010001010000000000000515BI0100001174 | 206 | no |
63 | 6.12 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. | BI01010001010000000000000515BI0100001175 | 305 | no |
64 | 6.13 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. | BI01010001010000000000000515BI0100001176 | 1145 | metre |
65 | 6.14 | Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. | BI01010001010000000000000515BI0100001177 | 360 | sqm |
66 | 6.15 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete:250x16mm | BI01010001010000000000000515BI0100001178 | 352 | no |
67 | 6.16 | Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete | BI01010001010000000000000515BI0100001179 | 50 | each |
68 | 6.17 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium | BI01010001010000000000000515BI0100001180 | 400 | no |
69 | 6.18 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium | BI01010001010000000000000515BI0100001181 | 274 | no |
70 | 6.19 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm | BI01010001010000000000000515BI0100001182 | 150 | no |
71 | 6.2 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm | BI01010001010000000000000515BI0100001183 | 250 | no |
72 | 6.21 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) | BI01010001010000000000000515BI0100001184 | 10 | sqm |
73 | 6.22 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5 mm depth and 5 mm width | BI01010001010000000000000515BI0100001185 | 3000 | metre |
74 | 6.23 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper | BI01010001010000000000000515BI0100001186 | 230 | no |
75 | 6.24 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper | BI01010001010000000000000515BI0100001187 | 85 | no |
76 | 6.25 | Providing and fixing in position frameless fixed glazing using 10mm toughened glass fitted with patch fittings of approved brand or manufacture as detailed in the draiwng of specified size including supplying and fixng necessary holdfats, screws for fixing cleats, toughened glass with all labour and materials complete as per drawings and as directed. | BI01010001010000000000000515BI0100001188 | 125 | sqm |
77 | 7 | Sub head -Steel Work | BI01010001010000000000000515BI0100001189 | ||
78 | 7.01 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc | BI01010001010000000000000515BI0100001190 | 10095 | kg |
79 | 7.02 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work | BI01010001010000000000000515BI0100001191 | 1276 | sqm |
80 | 7.03 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001192 | 71090 | kg |
81 | 7.04 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces | BI01010001010000000000000515BI0100001193 | 195 | sqm |
82 | 7.05 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | BI01010001010000000000000515BI0100001194 | 6375 | kg |
83 | 7.06 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes | BI01010001010000000000000515BI0100001195 | 50 | kg |
84 | 7.07 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover | BI01010001010000000000000515BI0100001196 | 15 | sqm |
85 | 7.08 | Providing and fixing ball bearing for rolling shutters. | BI01010001010000000000000515BI0100001197 | 4 | no |
86 | 7.09 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) | BI01010001010000000000000515BI0100001198 | 4570 | kg |
87 | 8 | Sub head -Flooring and Waterproofing Work | BI01010001010000000000000515BI0100001199 | ||
88 | 8.01 | Providing and laying C.C pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge ( The panel shuttering work shall be paid for separately) | BI01010001010000000000000515BI0100001200 | 142 | cum |
89 | 8.02 | Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete | BI01010001010000000000000515BI0100001201 | 9140 | kg |
90 | 8.03 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work | BI01010001010000000000000515BI0100001202 | 1882 | sqm |
91 | 8.04 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints of flooring tiles having joints of 3 mm width with spacer, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing with matching pigments etc., complete as per direction of Engineer-in-charge. Size of Tile 800x 800 mm.(Note - Basic Price of tile - Rs 765/sqm Any savings/reduction in basic price shall be accounted in the bill on pro rata basis ) | BI01010001010000000000000515BI0100001203 | 1213 | sqm |
92 | 8.05 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints of flooring tiles having joints of 3 mm width with spacer,jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and matching pigments finishing complete as per direction of Engineer-in-charge. Size of Tile 600 x 600 mm.(Note - Basic Price of tile - Rs 430/sqm Any savings/reduction in basic price shall be accounted in the bill on pro rata basis ) | BI01010001010000000000000515BI0100001204 | 11923 | sqm |
93 | 8.06 | Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints of flooring tiles having joints of 3mm width with spacer, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing using matching pigments etc. complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm. (Note - Basic Price of tile - Rs 430/sqm Any savings/reduction in basic price shall be accounted in the bill on pro rata basis ) | BI01010001010000000000000515BI0100001205 | 2244 | sqm |
94 | 8.07 | Providing and fixing Ist quality ceramic glazed wall tiles of size 600x600 conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), keeping 3mm space between tiles with spacer and fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive @ 4kg per sqm conforming to IS: 15477, in average 3mm thickness and finishing complete as per direction of Engineer-in-charge.(Note - Basic Price of tile - Rs 380/sqm Any savings/reduction in basic price shall be accounted in the bill on pro rata basis) | BI01010001010000000000000515BI0100001206 | 20206 | sqm |
95 | 8.08 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm | BI01010001010000000000000515BI0100001207 | 20206 | sqm |
96 | 8.09 | Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick | BI01010001010000000000000515BI0100001208 | 830 | sqm |
97 | 8.1 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. | BI01010001010000000000000515BI0100001209 | 1330 | metre |
98 | 8.11 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm | BI01010001010000000000000515BI0100001210 | 115 | sqm |
99 | 8.12 | Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work | BI01010001010000000000000515BI0100001211 | 300 | metre |
100 | 8.13 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent. | BI01010001010000000000000515BI0100001212 | 150 | sqm |
101 | 8.14 | Grading roof for water proofing treatment with:Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001213 | 226 | cum |
102 | 8.15 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer in-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm | BI01010001010000000000000515BI0100001214 | 1860 | sqm |
103 | 8.16 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. | BI01010001010000000000000515BI0100001215 | 5048 | sqm |
104 | 8.17 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | BI01010001010000000000000515BI0100001216 | 1391 | sqm |
105 | 8.18 | Vinyl flooring - Providing and installing PUR reinforced homogeneous Vinyl Flooring of approved make and colour / shade with skirting (done over coving cum capping pad of size 100x30mm) upto 100mm height, sheet 2 mtr wide and 15 - 23 mtr long, having a nominal total thickness of the wear layer of 2 mm and are produced with Phthalate-free Technology and total VOC emmissions < 10ug/m3 (after 28 days). The Slip Resistance should meet the R9 group and should be chemical resistance as per EN 423 & bacterial resistance as per EN ISO 846: Part C. The impact sound reduction should be as per EN ISO 717/2. The wear resistance should be tested as per EN 649 and and should come under the T Group criteria.The Light fastness should be tested in according to ISO-105 B02 and should be rated >6. The thermal resistance should be 0.01 m2 K/W. The static electrical discharge should be < 2kV (EN1815). Installation : It is important to ensure the sub floor on which the sheet is being laid is on smooth, flat & free from moisture, grease, etc.In case of uneven sub floor upto 3mm the same should be levelled by self levelling compound. The moisture level present in the sub floor should be less than 8% before installation of the floor.The installation shall be undertaken as per the manufacturers installation instructions and as directed by the Engineer-in-Charge. The joints should be minimum and heat welded with matching PVC rod so as to get a seamless perfect level surface. The rate shall be inclusive of cost and conveyance of all materials, labour etc complete as directed by the Engineer in charge. - for sterile areas | BI01010001010000000000000515BI0100001217 | 2508 | sqm |
106 | 8.19 | Anti static Vinyl flooring - Providing and installing PUR reinforced permanently static conductive pressed homogenous Vinyl flooring of approved make and colour / shade with skirting done over coving cum capping pad for OT`s/ICU's sheets 2 mtr wide and 15 - 23mtr long, having a nominal total thickness of the wear layer 2mm meeting EN 685 standards and are produced with Phthalate-free Technology and total VOC emmissions < 10ug/m3(after 28 days). The Slip Resistance should meet the R9 group and should be chemical resistance as per EN 423 & bacterial resistance as per EN ISO 846: Part C.The reaction to fire to meet EN 13501-1 standards.The wear resistance should be tested as per EN 649 and and should come under the P Group criteria.The light fastness should be tested in according to ISO 105- B02 and should be rated >7. The thermal resistance should be according to EN12667. The static electrical dischargeTest should meet EN 1815 standards(< 2kV). The electrical insulation to ground should meet VDE0100,part600. Installation : It is important to ensure the sub floor on which the sheet is being laid is smooth, flat & hard & free from moisture, grease, etc. In case of uneven sub floor upto 3mm the same should be levelled by self levelling compound and coved using pvc cove fillets . The moisture level present in the sub floor should be less than 8% before installation of the floor.The installation shall be undertaken as per the manufacturer's installation instructions and as directed by the Engineer-in-Charge. The joints should be minimum and heat welded with matching PVC rod so as to get a seamless perfect level surface. The rate shall be inclusive of cost and conveyance of all materials, labour etc complete as directed by the Engineer in charge. | BI01010001010000000000000515BI0100001218 | 420 | sqm |
107 | 8.2 | Vinyl wall dado - Supply and installation of HO Wallgard 014 1.3mm thick for wall covering works at all levels. The rate shall be inclusive of cost and conveyance of all materials, labour etc complete as directed by the Engineer in charge. - for sterile areas | BI01010001010000000000000515BI0100001219 | 3633 | sqm |
108 | 9 | Sub head -Specialized items | BI01010001010000000000000515BI0100001220 | ||
109 | 9.01 | Frosted film - Supply and installation of 3M make frosted film pattern throughout all the internal glass panels wherever required of approx. 1.5 m height as per the approved pattern. | BI01010001010000000000000515BI0100001221 | 150 | sqm |
110 | 9.02 | Coloured graphics pattern - Supply and installation of coloured graphics pattern / instructions / images etc over fixed glass panels / doors of approx. 1.5 m height as per the approved pattern. | BI01010001010000000000000515BI0100001222 | 100 | sqm |
111 | 9.03 | Anchoring of reinforcement bars in already casted concrete by drilling the required diameter holes at the required depth and as per the design diameter and applying anchoring chemical of Hilti or any approved make after cleaning the hole from all debriesand fixing the reinforcement bars in the chemical etc.complete. This is applicable only in case of extending the existing RCC work as per the direction of engineer in charge. | BI01010001010000000000000515BI0100001223 | 250 | no |
112 | 9.04 | Providing and fixing in position 25mm to 30 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints between Beams, Slabs and Columns at all level. | BI01010001010000000000000515BI0100001224 | 440 | per cm depth per 100 m |
113 | 9.05 | Providing and fixing sheet covering over expansion joints with iron screws as per design.Aluminium fluted strips 3.15 mm thick150 mm wide | BI01010001010000000000000515BI0100001225 | 348 | metre |
114 | 9.06 | Labour material and supervision charges for filling 25 mm baker road and PU sealant, providing synthetic expansion tape-Mapei band Tape 170 or equivalent on floor using Adesilex PG 2 of Mapei(in 1:3 ratio) or equivalent and filling PU sealant upto floor finish level and provide Aluminium 3.15 mm thick strips- 200 mm wide All complete as per manufacture specification. | BI01010001010000000000000515BI0100001226 | 807 | RM |
115 | 9.07 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)Complete as per design | BI01010001010000000000000515BI0100001227 | 30 | each |
116 | 9.08 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.66 mm overall thickness Partition with 8 mm thick double skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq cm, Bending Strength 100 kg/sq cm | BI01010001010000000000000515BI0100001228 | 350 | sqm |
117 | 9.09 | Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 49 Kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rowel plug & washers and held and in position by criss crossing GI wire etc. complete as per directions of Engineer-in-charge. | BI01010001010000000000000515BI0100001229 | 350 | sqm |
118 | 10 | Sub head -False Ceiling Work | BI01010001010000000000000515BI0100001230 | ||
119 | 10.01 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending | BI01010001010000000000000515BI0100001231 | 9200 | sqm |
120 | 10.02 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. | BI01010001010000000000000515BI0100001232 | 1625 | sqm |
121 | 10.03 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. | BI01010001010000000000000515BI0100001233 | 50 | sqm |
122 | 10.04 | Aluminium Non perforated false ceiling - Providing & Fixing true horizontal level swing down suspended ceiling comprising of approved make Aluminum Clip in Swing Down with double pip self-leveling feature and special tabs to allow swing down of tile to enable plenum access with plain visual consisting of 600X600 mm clip in plain tiles of 0.7mm uniform thickness Aluminum with bevel edge in approved color precoated with primer coat at the rear side with Light Reflectance > 60%.Tiles should have fire performance of Class A2-s1.d0 as per EN13501.The grade of aluminiumshall mandatorily be AA 3003. The AluminiumTile shall mandatorily be RoHS Compliant (Resistance of Hazardous Substance).Compliant certificate shall be provided on demand. The tile shall maintain uniform Thickness of 0.7mm across all areas of tiles with no deviation. The tile shall have paint thickness of 25 microns to enable better scratch resistance.The tile shall have the ability to combine the main light with extra illumination providing 77% light reflectance & enables to achieve light uniformity. The tile shall have g Ceiling Attenuation Class of 44db. It shall withstands upto 150 Scrub cycle using Scrubablity tester as per ASTM D 2486. The tile shall offer superior wash performance without compromising panel finish integrity using a washablity tester as per ASTM D 4828. Installation: To comprise 3000mm long "C" channels spaced at 1200mm centers securely fixed to the structural soffit by support clamp & approved hangers.The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm spring tee bars shall be spaced at 600mm centers in a direction perpendicular to the C-channels and shall be secured at every intersection with C channel using a tee bar hanger. Use T bar connector to splice two pieces of spring tee bars. Tiles should be clipped in between two spring tee bars from below. This is a downward installation. All full panels can be removed and reinstalled without movement up into the plenum area. Perimeter trims of approved color secured to walls at 450mm maximum centers. Cut tiles to be secured to the wall angles using a spring clamp. The installation shall be undertaken as per the manufacturers installation instructions and as directed by the Engineer-in-Charge. | BI01010001010000000000000515BI0100001234 | 2120 | sqm |
123 | 10.05 | Stainless Steel false ceiling - Providing and fixing in position stainless steel false ceiling of approx size 600 x 600 x 20mm with ceiling made of 1 mm thick stainless steel sheets of AISI 304 grade, visible side having satin/matt finish and coated with protective PVC taping.The joints of the stainless steel wall panels shall be made seamless, and homogeneous.There shall not be any sharp edges and all corners should be curved to avoid bacteria/fungal contamination.The Ceiling panels shall be supported to the slab with stainless steels brackets, fixtures and using nonferrous hard ware. The ceiling panel design and construction shall be provided with openings required for later inclusion of additional equipments, repair of installed equipments, without affecting the rigidity and strength of the structure. The joints between walls and ceiling(skirting) panels shall be connected by curved panels at a radius of 450mm. All provisions shall be in the Operation theatre ceiling for mounting other equipment i.e. Ceiling-mounted Operation theatre light, Pendants, Brackets for monitors, Cameras etc. complete. The rate shall also be inclusive of all materials, labour, transportation etc. complete. | BI01010001010000000000000515BI0100001235 | 545 | sqm |
124 | 10.06 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long space between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening of services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 Kg/ sq. cm, bending strength 100 Kg/sq. cm, of size 595x595 mm, having perforation of dia, 10 mm with minimum perforated area 18% with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 Kg/cum backing. | BI01010001010000000000000515BI0100001236 | 1166 | sqm |
125 | 11 | Sub head -Finishes | BI01010001010000000000000515BI0100001237 | ||
126 | 11.01 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | BI01010001010000000000000515BI0100001238 | 11795 | sqm |
127 | 11.02 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | BI01010001010000000000000515BI0100001239 | 42882 | sqm |
128 | 11.03 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | BI01010001010000000000000515BI0100001240 | 21441 | sqm |
129 | 11.04 | Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand). | BI01010001010000000000000515BI0100001241 | 13580 | sqm |
130 | 11.05 | Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. | BI01010001010000000000000515BI0100001242 | 1995 | metre |
131 | 11.06 | Providing and fixing PVC chicken mesh of approved quality in the junction of RCC beam and block masonry atleast 100 mm on either face.(total 200mm width ) all complete as directed by the Engineer in charge. | BI01010001010000000000000515BI0100001243 | 370 | sqm |
132 | 11.07 | 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). | BI01010001010000000000000515BI0100001244 | 25475 | sqm |
133 | 11.08 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1 Cement : 4 coarse sand) | BI01010001010000000000000515BI0100001245 | 6009 | sqm |
134 | 11.09 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 ( 1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001246 | 8729 | sqm |
135 | 11.1 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ( 1 cement : 6 fine sand). | BI01010001010000000000000515BI0100001247 | 3704 | sqm |
136 | 11.11 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. | BI01010001010000000000000515BI0100001248 | 9030 | sqm |
137 | 11.12 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. | BI01010001010000000000000515BI0100001249 | 42200 | kg |
138 | 11.13 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification . | BI01010001010000000000000515BI0100001250 | 1.02925e+06 | kg |
139 | 11.14 | Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm | BI01010001010000000000000515BI0100001251 | 9077 | sqm |
140 | 11.15 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | BI01010001010000000000000515BI0100001252 | 3026 | sqm |
141 | 11.16 | Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage. | BI01010001010000000000000515BI0100001253 | 175 | metre |
142 | 12 | Sub head - Finishing and Roofing | BI01010001010000000000000515BI0100001254 | ||
143 | 12.01 | Polycarbonate sheet roofing for super speciality block - Providing, installing and fixing profiled sheeting using premium quality single skin polycarbonate sheet having minimum thickness of 3mm supported on steel members. The structural steel members shall include rafters and purlins made of steel hollow sections of approx. size 50mm x 50mm x 1.6mm thick, purlin support of approx. size 25mm x 25mm x 1.6mm thick, fabricated posts and lattice of approx. size 30mm x 30mm x 1.6mm thick. All steel members shall be preferably galvanized pipe standard hollow sections. The spacing of the rafters / purlins should be controlled in such a way that it is placed right under the joints of the roofing sheet. Roofing sheet shall be factory cut and required length to suite site conditions and design drawings. Roofing sheet shall be crest fixed to purlins with hot dip 'galvanized self drilling fasteners with integral EPDM washers (one fastener on each crest). Also, fasteners to be provided on side laps. Minimum sheet overlap at end laps shall be 150mm. Penetration and end laps in sheet shall be sealed by using proper sealant. Profiled HDPE fillers shall be provided wherever required to close voids between capings and troughs of the sheet to provide a weather tight exterior. Rate shall be inclusive of cost and conveyance of all materials, painting of steel members using two coats of approved make and colour synthetic enamel paint over two coats of approved make anti - corrosive approved zinc chromate primer, lead, lift, scaffolding, all labour charges, making the roof water tight with required sealant etc. complete at all level and as directed by Engineer-in-Charge.(Note: The contractor shall take prior approval for the materials to be used for the work from the concerned Authority) | BI01010001010000000000000515BI0100001255 | 570 | sqm |
144 | 12.02 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001256 | 2570 | sqm |
145 | 12.03 | Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2 | BI01010001010000000000000515BI0100001257 | 400 | metre |
146 | 13 | Sub head - External Work | BI01010001010000000000000515BI0100001258 | ||
147 | 13.01 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | BI01010001010000000000000515BI0100001259 | 75 | cum |
148 | 13.02 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001260 | 10 | sqm |
149 | 13.03 | Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved | BI01010001010000000000000515BI0100001261 | 100 | cum |
150 | 13.04 | Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar | BI01010001010000000000000515BI0100001262 | 50 | cum |
151 | 13.05 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | BI01010001010000000000000515BI0100001263 | 25 | cum |
152 | 14 | Sub head - Tree Cutting and Other External Work | BI01010001010000000000000515BI0100001264 | ||
153 | 14.01 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth | BI01010001010000000000000515BI0100001265 | 5 | each |
154 | 14.02 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth | BI01010001010000000000000515BI0100001266 | 4 | each |
155 | 14.03 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth | BI01010001010000000000000515BI0100001267 | 8 | each |
156 | 14.04 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth | BI01010001010000000000000515BI0100001268 | 2 | each |
157 | 14.05 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | BI01010001010000000000000515BI0100001269 | 2800 | sqm |
158 | 14.06 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm | BI01010001010000000000000515BI0100001270 | 75 | metre |
159 | 14.07 | Carriage of RCC pipe 300 mm dia above 50 m up to 100 m | BI01010001010000000000000515BI0100001271 | 75 | metre |
160 | 14.08 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes. | BI01010001010000000000000515BI0100001272 | 60 | metre |
161 | 14.09 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.600 mm dia RCC pipes. | BI01010001010000000000000515BI0100001273 | 25 | metre |
162 | 14.1 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001274 | 165 | cum |
163 | 14.11 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001275 | 25 | cum |
164 | 14.12 | Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing | BI01010001010000000000000515BI0100001276 | 651 | sqm |
165 | 14.13 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. | BI01010001010000000000000515BI0100001277 | 4750 | sqm |
166 | 14.14 | Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 | BI01010001010000000000000515BI0100001278 | 1425 | cum |
167 | 14.15 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. | BI01010001010000000000000515BI0100001279 | 3420 | sqm |
168 | 14.16 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-40 grade with approved color design and pattern. | BI01010001010000000000000515BI0100001280 | 4075 | sqm |
169 | 14.17 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. | BI01010001010000000000000515BI0100001281 | 450 | sqm |
170 | 14.18 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge) | BI01010001010000000000000515BI0100001282 | 45 | cum |
171 | 14.19 | Provision for removing the waste from STP disinfecting and treating with lime. | BI01010001010000000000000515BI0100001283 | 1 | L.S |
172 | 15 | Sub head - Site Clearence | BI01010001010000000000000515BI0100001284 | ||
173 | 15.01 | Uprooting and Removing Stumps & Roots: Uprooting and Removing Stumps & roots, compaction of backfilling and stacking of servicable material by manual means as per Technical Specification Clause 201.A.Lead upto 100 m(i)Girth above 300 mm to 600 mm | BI01010001010000000000000515BI0100001285 | 5 | each |
174 | 15.02 | Uprooting and Removing Stumps & Roots: Uprooting and Removing Stumps & roots, compaction of backfilling and stacking of servicable material by manual means as per Technical Specification Clause 201.A. Lead upto 100 m (ii)Girth above 600 mm to 900 mm | BI01010001010000000000000515BI0100001286 | 2 | each |
175 | 15.03 | Uprooting and Removing Stumps & Roots: Uprooting and Removing Stumps & roots, compaction of backfilling and stacking of servicable material by manual means as per Technical Specification Clause 201.A. Lead upto 100 m (iii)Girth above 900 mm to 1800 mm | BI01010001010000000000000515BI0100001287 | 5 | each |
176 | 15.04 | Uprooting and Removing Stumps & Roots: Uprooting and Removing Stumps & roots, compaction of backfilling and stacking of servicable material by manual means as per Technical Specification Clause 201.A. Lead upto 100 m (iv)Girth above 1800 mm to 2700 mm | BI01010001010000000000000515BI0100001288 | 3 | each |
177 | 15.05 | Uprooting and Removing Stumps & Roots: Uprooting and Removing Stumps & roots, compaction of backfilling and stacking of servicable material by manual means as per Technical Specification Clause 201.A. Lead upto 100 m (v)Girth above 2700 mm to 4500 mm | BI01010001010000000000000515BI0100001289 | 2 | each |
178 | 16 | Sub head - Wall guard and corner guard | BI01010001010000000000000515BI0100001290 | ||
179 | 16.01 | Supply and installation of Wall Guards cum hand rails with the following specification. The wall Guards shall be of height 140mm with an outer cover made out of PVC,PP/ABS with an interior core of high quality aluminium design with anti corrosive strips. The wall guards shall be fitted to the tile surface with adequate fasteners and anchor screws and braces. The thickness of vinyl and aluminium shall be 1.5mm.The surface texture shall be fire resistant . The units shall be of approved make and colour. As per Annexure II, Item No. 8 Wall Guard cum hand rails. | BI01010001010000000000000515BI0100001291 | 600 | metre |
180 | 16.02 | Supply and installation of Brace for wall guards with the following specification. The Brace shall be made out of PVC with a thickness of 1.5mm. The Brace shall be provided at an interval of 500mm. The Brace shall be of approved make and colour. This item shall be a part of Item No. 16.01 | BI01010001010000000000000515BI0100001292 | 1500 | each |
181 | 16.03 | Supply and installation of Elbow for wall guards with the following specification. The elbow shall be of height 140mm which shall be provided at the corners. The Outer Cover shall be made out of PVC,PP/ABS with an interior core of high quality aluminium design with anti corrosive strips. The thickness of vinyl and aluminium shall be 1.5mm. The surface texture shall be fire resistant . The units shall be of approved make and colour. This item shall be a part of Item No. 16.01 | BI01010001010000000000000515BI0100001293 | 510 | each |
182 | 16.04 | Supply and installation of Wall Guard with the following specification. The wall Guards shall be of height 100mm with an outer cover made out of PVC,PP/ABS with an interior core of high quality aluminium design with anti corrosive strips. The wall guards shall be fitted to the tile surface with adequate fasteners and anchor screws and braces. The thickness of vinyl and aluminium shall be 1.5mm.The surface texture shall be fire resistant. The units shall be of approved make and colour. As per Annexure II, Item No. 8. Wall Guard | BI01010001010000000000000515BI0100001294 | 600 | metre |
183 | 16.05 | Supply and installation of End cap for Wall Guards with the following specification. The end cap for wall Guards shall be of height 100mm with an outer cover made out of PVC,PP/ABS. The End cap shall be fitted to the at every termination of wall guards. The surface texture shall be fire resistant. The units shall be of approved make and colour. This item shall be a part of Item No. 16.04. End Cap | BI01010001010000000000000515BI0100001295 | 510 | each |
184 | 16.06 | Supply and installation of corner guards made ourt of Stainless Steel 304 Grade material of thickness 1mm with an inside rubber backup of thickness 1.5mm of approved make and shall be fitted to the corner of the wall to the finished wall tile using anchor screws.. Each corner guard shall be of dimension 35mmx35mmx1500mm(H) and of approved make. As per Annexure II, Item No. 13. | BI01010001010000000000000515BI0100001296 | 455 | metre |
185 | 17 | Sub head Signage | BI01010001010000000000000515BI0100001297 | ||
186 | 17.01 | Supply and installation of way finding signages as per following specifications. The signages shall be plotter cut 2 mil 3M or equivalent pigmented translucent vinyl pasted on3mm thick ACP/ 6mm thick hybrid board on both Sides of approved make and colour. The vinyl shall conform to class A rating for fire retardant as per ASTM E84 standard. The signage shall be ceiling suspended using Stainless Steel strings as per the directions of engineer in charge. Contractor shall get approval for the design before fabrication. As per Annexure II, Item No. 1. Way Finding Signage: 1200mmx600mm | BI01010001010000000000000515BI0100001298 | 100 | each |
187 | 17.02 | Supply and installation of door signage with the following specification. The signages shall be plotter cut 2 mil 3M or equivalent pigmented translucent vinyl of approved design pasted on 3mm thick sunboard and installed on doors using VHB tapes. The vinyl shall conform to class A rating for fire retardant as per ASTM E84 standard. Contractor shall get approval for the design before fabrication. As per Annexure II, Item No. 2. Door Signage: 300mmx100mm | BI01010001010000000000000515BI0100001299 | 1000 | each |
188 | 17.03 | Supply and installation of Aluminium profile sliding door signage with the following specifications. The signage shall have an aluminium profile modular frame of height 100mm. The letters shall be plotter cut 2 mil 3M or equivalent pigmented translucent vinyl of approved design pasted on 3mm thick sunboard/ ACP Board. The vinyl shall conform to class A rating for fire retardant as per ASTM E84 standard and shall be fixed with adequate fasteners. The signage shall be in such a way that the Sunboard/ACP Board is slid to the aluminium profile for easy replacement of names. Contractor shall get approval for the design before fabrication. As per Annexure II, Item No. 3. Aluminium profile sliding, door signage. 300mmx100mm | BI01010001010000000000000515BI0100001300 | 45 | each |
189 | 17.04 | Supply and installation of aluminium profile toilet signage with the following specification. The signage shall have an aluminium profine frame of thickness 2mm. The letters shall be plotter cut 2 mil 3M or equivalent pigmented translucent vinyl of approved design. The vinyl shall conform to class A rating for fire retardant as per ASTM E84 standard and shall be fixed with adequate fasteners. The signage shall be in such a way that the Sunboard/ACP Board is slid to the aluminium profile for easy replacement of names. The signage shall be of approved colour and design. Contractor shall get approval for the design before fabrication. As per Annexure II, Item No. 4.Toilet Signage- 150mmx100mm. | BI01010001010000000000000515BI0100001301 | 60 | each |
190 | 17.05 | Supply and installation of illuminted signage of dimension 600mmx200mm with a projection of 90mm made out of acrylic box of thickness 3mm in the front and 4mm thickness in the sides wall mounted with necessary accessories. Signages shall be plotter cut 2 mil 3M or equivalent pigmented translucent vinyl with a minimum height of 120mm of approved design and colour. The vinyl shall conform to class A rating for fire retardant as per ASTM E84 standard. Contractor shall get approval for the design before fabrication. As per Annexure II, Item No. 5. | BI01010001010000000000000515BI0100001302 | 45 | each |
191 | 17.06 | Supply and installation of illuminated Round signage of diameter 600mm with the following specifications. The signage shall me made out of 50mm projectd ACP base with letters made out of 60mm projected 3mm Acrylic box of approved height. The first phase shall be pasted with 3M or equivalent vinyl with LED for each letters of approved make and metal frame for letters including all necessary accessories. The signage shall be of approved design colour and make. Contractor shall get approval for the design before fabrication. As per Annexure II, Item No. 6. | BI01010001010000000000000515BI0100001303 | 15 | each |
192 | 17.07 | Supply and installation of illuminated signage with the following specifications. The letters shall be made out of 70mm projected 3mm Acrylic box of height 800mm. The first phase shall be pasted with 3M or equivalent vinyl with LED for each letters of approved make and metal frame for letters including all necessary accessories. Contractor shall get approval for the design before fabrication.As per Annexure II, Item No. 7. Illuminated Main Signage. | BI01010001010000000000000515BI0100001304 | 18 | sqm |
193 | 18 | Electrical Works | |||
194 | 18.001 | 625KVA DIESEL GENERATOR\nSupply, Installation, Testing & commissioning of 'Silent Type' Diesel Generating Sets along with acoustic enclosure having Prime Power Rating of 500KW at 1500 RPM 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 Phase system & for 0.85 Load factor (Detailed Technical Specification Attached) | 2 | Set | |
195 | 18.002 | EXHAUST PIPES\nSupplying and fixing exhaust gas piping of suitable dia specified by the OEM for 625KVA DG with black M.S 'B' class pipe welded confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer in charge and the rate inclusive of all minor civil works required, bolts, clamps etc. as required for installation. Necessary MS Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust. | 1 | Set | |
196 | 18.003 | SITC of Outdoor Type RMU with Metering Cubicle (Detailed Technical Specification Attached). | 1 | Set | |
197 | 18.004 | SITC of HT Panel (Detailed Technical Specification Attached). | 1 | Set | |
198 | 18.005 | 750KVA - 11kV/433V Cast Resin (Dry type) Laser Scribed Transformer\nSupply, installation, testing & commissioning of 1No. of 750kVA 11kV/433V indoor cast resin dry type transformer with laser scribed core and copper winding, connected Delta on HT side and Star on LT side with "ON Load Tap Changer" having a continuous rating for 11kV / 433V 3 phase 50 Hz. Vector group Dyn 11 with tapping's from +5% to -10% in steps of 2.5 %, AVR & RTCC, include separate winding temperature indicator for each phase and core in the Transformer. Insulation Class 'F'.Transformer should be directly connected to cable on HV side and have suitable adaptor box on LV side for connecting 1250A AL BBT with all accessories, complete as required and losses as per ECBC, IE rules specifications. The transformer shall confirm to IS 2026, 11171/1985 with latest amendment etc. complete. \n(Detailed Technical Specification Attached). | 2 | Set | |
199 | 18.006 | Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Indoor type Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 No's aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 No's CU strip of 25x3mm including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. \n1250 amps 36kA SC for 1 sec | 54 | metre | |
200 | 18.007 | MAIN SWITCH BOARD\nFabrication, supply, erection, testing and commissioning of TTA type, Indoor Cubicle , dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge and as shown in the schematic layout provided. \nThe panel shall be with PLC components for interlocking of incoming breakers & bus couplers, UPS for PLC and all connections and interconnections required for PLC Logic Operations for interlocking of breakers as indicated in schematic.\n(Detailed Technical Specification attached) | 1 | Nos | |
201 | 18.008 | DG SYNCH PANEL\nFabrication, supply, erection, testing and commissioning of TTA, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge and as shown in the schematic layout provided. \nThe panel shall be with PLC components for Synchronisation of 2Nos. of 625KVA DG Sets and 1No. 400KVA, Auto Load Sharing, AMF which includes synchronising relays, UPS for PLC and all connections and interconnections required for synchronising and load sharing for 3 nos. of DG sets and individual Generator selection and control facilities as well as mimic diagram. (Detailed Technical Specification attached) | 1 | Nos | |
202 | 18.009 | FLOOR PANEL-1\nFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge and as shown in the schematic layout provided.(Refer SLD) | 1 | Nos | |
203 | 18.01 | FLOOR PANEL-2\nFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
204 | 18.011 | LOWER GROUND -1 PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
205 | 18.012 | GROUND -FLOOR PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
206 | 18.013 | FIRST FLOOR PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
207 | 18.014 | SECOND FLOOR PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
208 | 18.015 | THIRD FLOOR PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
209 | 18.016 | FOURTH FLOOR PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
210 | 18.017 | FIFTH FLOOR PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
211 | 18.018 | SIXTH & TERRACE FLOOR PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
212 | 18.019 | GROUND FLOOR UPS PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.(Refer SLD) | 1 | Nos | |
213 | 18.02 | FOURTH FLOOR UPS PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
214 | 18.021 | FIFTH FLOOR UPS PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
215 | 18.022 | OT PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
216 | 18.023 | EMERGENCY LIGHTING PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
217 | 18.024 | UPS INPUT PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
218 | 18.025 | MEDICAL EQUIPMENT PANEL\nFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
219 | 18.026 | APFC PANEL-300KVAR\nFabrication, supply, erection, testing and commissioning of PTTA Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.\nAPFC PANEL - With inbuilt solid state automatic power factor correction arrangement having microprocessor based control circuit and contactor switching power circuit having a required capacity of 300KVAR having capacitor bank in steps of [(2x50KVAR)+(6x25KVAR)+(2x10KVAR)+(1x15KVAR)]+ fixed capacitor of (1 x 15 KVAR), including main MCCB, MCB's, APFC relay, contactors, Reactors, capacitors, indicating lamps, etc. Complete with all necessary hardware & accessories. (Refer SLD) | 2 | Nos | |
220 | 18.027 | MAIN LIFT PANEL\nFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
221 | 18.028 | LIFT PANEL-1\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
222 | 18.029 | LIFT PANEL-2\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
223 | 18.03 | LIFT PANEL-3\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
224 | 18.031 | PLUMBING PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
225 | 18.032 | UPS O/P PANEL\nFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. (Refer SLD) | 1 | Nos | |
226 | 18.033 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx400sq.mm Al Cable | 830 | Metre | |
227 | 18.034 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx300sq.mm Al Cable | 160 | Metre | |
228 | 18.035 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx240sq.mm Al Cable | 935 | Metre | |
229 | 18.036 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx185sq.mm Al Cable | 500 | Metre | |
230 | 18.037 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx150sq.mm Al Cable | 15 | Metre | |
231 | 18.038 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx120sq.mm Al Cable | 80 | Metre | |
232 | 18.039 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx95sq.mm Al Cable | 1055 | Metre | |
233 | 18.04 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx70sq.mm Al Cable | 165 | Metre | |
234 | 18.041 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx50sq.mm Al Cable | 595 | Metre | |
235 | 18.042 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx35sq.mm Al Cable | 540 | Metre | |
236 | 18.043 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx25sq.mm Al Cable | 550 | Metre | |
237 | 18.044 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx16sq.mm Al Cable | 851 | Metre | |
238 | 18.045 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx10sq.mm Al Cable | 8193 | Metre | |
239 | 18.046 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3cx10sq.mm CU Cable | 1056 | Metre | |
240 | 18.047 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3cx04sq.mm CU Cable | 150 | Metre | |
241 | 18.048 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3cx2.5sq.mm CU Cable | 180 | Metre | |
242 | 18.049 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx16sq.mm CU Cable | 30 | Metre | |
243 | 18.05 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx10sq.mm CU Cable | 430 | Metre | |
244 | 18.051 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 6C x 1.5sq.mm Cu Control Cable | 100 | Metre | |
245 | 18.052 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4C x 1.5sq.mm Cu Control Cable | 300 | Metre | |
246 | 18.053 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3C x 1.5sq.mm CU Shielded Arm Cable | 150 | Metre | |
247 | 18.054 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3C x 1.5sq.mm Cu Control Cable | 348 | Metre | |
248 | 18.055 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 2C x 1.5sq.mm Cu Control Cable | 520 | Metre | |
249 | 18.056 | Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages etc. as required and instructed by engineer in charge.\n1C x 95sq.mm Copper Flexible Cable | 780 | Metre | |
250 | 18.057 | Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages etc. as required and instructed by engineer in charge.\n1C x 35sq.mm Copper Flexible Cable | 30 | Metre | |
251 | 18.058 | Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages etc. as required and instructed by engineer in charge.\n1C x 25sq.mm Copper Flexible Cable | 300 | Metre | |
252 | 18.059 | Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages etc. as required and instructed by engineer in charge.\n1C x 16sq.mm Copper Flexible Cable | 540 | Metre | |
253 | 18.06 | Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages etc. as required and instructed by engineer in charge.\n1C x 10sq.mm Copper Flexible Cable | 240 | Metre | |
254 | 18.061 | Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages etc. as required and instructed by engineer in charge.\n1C x 06sq.mm Copper Flexible Cable | 100 | Metre | |
255 | 18.062 | \nSupply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages etc. as required and instructed by engineer in charge.\n1C x 04sq.mm Copper Flexible Cable | 180 | Metre | |
256 | 18.063 | Supply of following 11kV (E) grade XLPE insulated PVC sheathed armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relevant standard. \n3cx300sq.mm XLPE Cable | 400 | Metre | |
257 | 18.064 | Supply & laying of DWC pipe in ground level excluding excavation 110/94 mm or nearest size. | 400 | Metre | |
258 | 18.065 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: \n300 sq. mm | 9 | Each | |
259 | 18.066 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : \n300 sq. mm | 1 | Each | |
260 | 18.067 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : \n300 sq. mm | 2 | Each | |
261 | 18.068 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 1/2X 400 sq. mm (82mm) | 32 | Set | |
262 | 18.069 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 1/2X 300 sq. mm (70mm) | 10 | Set | |
263 | 18.07 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 1/2X 240 sq. mm (62mm) | 14 | Set | |
264 | 18.071 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 1/2X 185 sq. mm (57mm) | 12 | Set | |
265 | 18.072 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 1/2 X 150 sq. mm (50mm) | 2 | Set | |
266 | 18.073 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 1/2 X 120 sq. mm (45mm) | 2 | Set | |
267 | 18.074 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 1/2X 95 sq. mm (45mm) | 18 | Set | |
268 | 18.075 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 1/2X 70 sq. mm (38mm) | 4 | Set | |
269 | 18.076 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 1/2 X 50 sq. mm (35mm) | 14 | Set | |
270 | 18.077 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n4C X 35 sq. mm (32mm) | 12 | Set | |
271 | 18.078 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n4C X 25 sq. mm (28mm) | 10 | Set | |
272 | 18.079 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n4C X 16 sq. mm (28mm) | 48 | Set | |
273 | 18.08 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n4C X 10 sq. mm (25mm) | 308 | Set | |
274 | 18.081 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 X 10 sq. mm (22mm) | 72 | Set | |
275 | 18.082 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. \n2C X 1.5 sq. mm | 20 | Set | |
276 | 18.083 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. \n3C X 1.5 sq. mm | 42 | Set | |
277 | 18.084 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. \n4C X 1.5 sq. mm | 18 | Set | |
278 | 18.085 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. \n6C X 1.5 sq. mm | 240 | Set | |
279 | 18.086 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. \n4C X 16 sq. mm (28mm) | 2 | Set | |
280 | 18.087 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. \n4C X 10 sq. mm (25mm) | 20 | Set | |
281 | 18.088 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. \n3C X 04 sq.mm | 8 | Set | |
282 | 18.089 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. \n3C X 2.5 sq.mm | 6 | Set | |
283 | 18.09 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. \n95 sq. mm | 44 | Set | |
284 | 18.091 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. \n35 sq. mm | 6 | Set | |
285 | 18.092 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. \n25 sq. mm | 8 | Set | |
286 | 18.093 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. \n16 sq. mm | 6 | Set | |
287 | 18.094 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. \n10 sq. mm | 24 | Set | |
288 | 18.095 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. \n6 Sq. mm | 6 | Set | |
289 | 18.096 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. \n4 sq. mm | 12 | Set | |
290 | 18.097 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.\nUp to 35 sq. mm. | 1452 | Metre | |
291 | 18.098 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.\nAbove 35 sq. mm and up to 95 sq. mm | 300 | Metre | |
292 | 18.099 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.\nAbove 95 sq. mm and up to 185 sq. mm | 15 | Metre | |
293 | 18.1 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.\nAbove 185 sq. mm and up to 400 sq. mm | 50 | Metre | |
294 | 18.101 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. \nAbove 185 sq. mm and up to 400 sq. mm | 30 | Metre | |
295 | 18.102 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. \nUp to 35 sq. mm | 1500 | Metre | |
296 | 18.103 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. \nAbove 35 sq. mm and up to 95 sq. mm | 150 | Metre | |
297 | 18.104 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. \nAbove 95 sq. mm and up to 185 sq. mm | 70 | Metre | |
298 | 18.105 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. \nAbove 185 sq. mm and up to 400 sq. mm | 500 | Metre | |
299 | 18.106 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. \nUp to 35 sq. mm (clamped with 1mm thick saddle) | 9300 | Metre | |
300 | 18.107 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. \nAbove 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp) | 1365 | Metre | |
301 | 18.108 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. \nAbove 95 sq. mm and up to 185 sq. mm (clamped with 25/40x3mm MS flat clamp) | 450 | Metre | |
302 | 18.109 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. \nAbove 185 sq. mm and up to 400 sq. mm (clamped with 40x3mm MS flat clamp) | 1450 | Metre | |
303 | 18.11 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. | 150 | No | |
304 | 18.111 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. \nAbove 120 sq. mm and up to 400 sq. mm | 270 | Metre | |
305 | 18.112 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. \nAbove 120 sq. mm and up to 400 sq. mm | 60 | Metre | |
306 | 18.113 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. \nAbove 120 sq. mm and up to 400 sq. mm | 60 | Metre | |
307 | 18.114 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. \nAbove 120 sq. mm and up to 400 sq. mm | 30 | Metre | |
308 | 18.115 | Excavation for cable trenches in soft soil, depth up to 1.2 m including dressing of sides lift up to 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc. in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 256 | Cum | |
309 | 18.116 | Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres. | 120 | Cum | |
310 | 18.117 | Deduct for not consolidation by ramming and watering while re-filling with sand and or good soil in cable/ pipe laying. | 50 | Cum | |
311 | 18.118 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required \n100 mm dia | 18 | Metre | |
312 | 18.119 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. \n160 mm dia (OD-160 mm & ID-135 mm nominal) | 45 | Metre | |
313 | 18.12 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. \nPrimary Point (Switch to First Light Point) | 2066 | Point | |
314 | 18.121 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required | 15 | Point | |
315 | 18.122 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. \n3 X 1.5 sq.mm | 28500 | Metre | |
316 | 18.123 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. \n3 x 2.5 sq. mm | 47500 | Metre | |
317 | 18.124 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. \n3 x 4 sq. mm | 6800 | Metre | |
318 | 18.125 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. \n3 x 6 sq. mm | 240 | Metre | |
319 | 18.126 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. \n100 mm X 100 mm X 60 mm deep | 30 | Each | |
320 | 18.127 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. \n250 mm X 300 mm X 60 mm deep | 12 | Each | |
321 | 18.128 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. \n5/6 amps switch | 698 | Each | |
322 | 18.129 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. \n15/16 amp switch | 276 | Each | |
323 | 18.13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. \n3 pin 5/6 amp socket outlet | 698 | Each | |
324 | 18.131 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. \n6 pin 15/16 amp socket outlet | 276 | Each | |
325 | 18.132 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | 190 | Each | |
326 | 18.133 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. \n1 or 2 Module (75mmX75mm) | 410 | Each | |
327 | 18.134 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. \n3 Module (100mmX75mm) | 265 | Each | |
328 | 18.135 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. \n6 Module | 145 | Each | |
329 | 18.136 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. \n3 Module | 270 | Each | |
330 | 18.137 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 723 | Each | |
331 | 18.138 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | 497 | Each | |
332 | 18.139 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required. | 750 | Each | |
333 | 18.14 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) \nStep Fan regulator - type 2 M | 397 | Each | |
334 | 18.141 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) \n16A 3 pin plug top | 15 | Each | |
335 | 18.142 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). | 155 | Each | |
336 | 18.143 | Supplying & fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. | 15 | Each | |
337 | 18.144 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required \n8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | 1 | Each | |
338 | 18.145 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required \n6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | 2 | Each | |
339 | 18.146 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required \n4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | 2 | Each | |
340 | 18.147 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required \n12 way (8+36) - Three phase double cover Horizontal DB (IP 42/43) | 9 | Each | |
341 | 18.148 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required \n8 way (8+24) - Three phase double cover Horizontal DB (IP 42/43) | 8 | Each | |
342 | 18.149 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required \n6 way (8+18) - Three phase double cover Horizontal DB (IP 42/43) | 13 | Each | |
343 | 18.15 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required \n4 way (8+12) - Three phase double cover Horizontal DB (IP 42/43) | 36 | Each | |
344 | 18.151 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator \n8 way, Double door | 1 | Each | |
345 | 18.152 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator \n6 way, Double door | 7 | Each | |
346 | 18.153 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. \n63 amps | 1 | Each | |
347 | 18.154 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. \n40 amps | 4 | Each | |
348 | 18.155 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. \n32 amps | 25 | Each | |
349 | 18.156 | Supplying and fixing following rating 25A, FP, 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 24 | Each | |
350 | 18.157 | Supplying and fixing following rating 32A, FP, 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 1 | Each | |
351 | 18.158 | Supplying and fixing following rating 25A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 1 | Each | |
352 | 18.159 | Supplying and fixing following rating 32A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 14 | Each | |
353 | 18.16 | Supplying and fixing following rating 40A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 10 | Each | |
354 | 18.161 | Supplying and fixing following rating 63A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 1 | Each | |
355 | 18.162 | Supplying and fixing following rating 25A, DP, 240 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 7 | Each | |
356 | 18.163 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. \nSingle pole | 951 | Each | |
357 | 18.164 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "D" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. \nSingle pole | 376 | Each | |
358 | 18.165 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. \nDouble pole | 2 | Each | |
359 | 18.166 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. \nTriple pole | 13 | Each | |
360 | 18.167 | Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. \nTriple pole | 4 | Each | |
361 | 18.168 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | 284 | Each | |
362 | 18.169 | Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required \n3 output (1output per phase) and suitable for three phase supply | 1 | No | |
363 | 18.17 | Supplying and fixing FP sheet steel enclosure on surface/ recess along with 25/32/40amps 415 volts "C" curve FP MCB complete with connections, testing and commissioning etc. as required. | 40 | No | |
364 | 18.171 | SITC of Lockable off push button near pumps & Cooling Tower | 15 | No | |
365 | 18.172 | Supplying and fixing following rating, four pole, 415 volts, isolator in MS Enclosure complete with connections, testing and commissioning etc. as required. \n100 amps FP Isolator | 1 | No | |
366 | 18.173 | Supplying and fixing following rating, TPN, 415 volts, MCCB in MS Enclosure complete with connections, testing and commissioning etc. as required. \n125 amps TPN MCCB | 2 | No | |
367 | 18.174 | Supplying and fixing following rating, TPN, 415 volts, MCCB in MS Enclosure complete with connections, testing and commissioning etc. as required. \n160 amps TPN MCCB | 1 | No | |
368 | 18.175 | Supplying and fixing following rating, TPN, 415 volts, MCCB in MS Enclosure complete with connections, testing and commissioning etc. as required. \n200 amps TPN MCCB | 1 | No | |
369 | 18.176 | Supplying and fixing following rating, TPN, 415 volts, MCCB in MS Enclosure complete with connections, testing and commissioning etc. as required. \n250 amps TPN MCCB | 1 | No | |
370 | 18.177 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.\n20 mm | 420 | Metre | |
371 | 18.178 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. \n25 mm | 330 | Metre | |
372 | 18.179 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.\n32 mm | 75 | Metre | |
373 | 18.18 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.\n20 mm | 27500 | Metre | |
374 | 18.181 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.\n25 mm | 34500 | Metre | |
375 | 18.182 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.\n32 mm | 1500 | Metre | |
376 | 18.183 | Supplying and installing perforated Hot Dipped Galvanised Perforated cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, Rate is inclusive of factory fabricated Tee's, Reducer, Bends etc. as required.\n300 mm width X 50 mm depth X 1.6 mm thickness | 1820 | Metre | |
377 | 18.184 | Supplying and installing perforated Hot Dipped Galvanised Perforated cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, Rate is inclusive of factory fabricated Tee's, Reducer, Bends etc. as required.\n450 mm width X 50 mm depth X 2.0 mm thickness | 55 | Metre | |
378 | 18.185 | Providing and fixing the following 14 SWG Hot Dip Galvanised Ladder tray (Bolted/Fabricated) along with necessary GI suspenders (not more than 1000 MM long) at equal intervals of 900 mm as directed. Including providing cost of GI supports, nuts, bolts, washers and dash fasteners as required. The installation shall be complete in all respects (All accessories like tees, bends vertical / horizontal shall be factory fabricated and cost of these to be included in the rate).\n450 mm width X 50 mm depth X 2.0 mm thickness | 600 | Metre | |
379 | 18.186 | Providing and fixing the following 14 SWG Hot Dip Galvanised Ladder tray (Bolted/Fabricated) along with necessary GI suspenders (not more than 1000 MM long) at equal intervals of 900 mm as directed. Including providing cost of GI supports, nuts, bolts, washers and dash fasteners as required. The installation shall be complete in all respects (All accessories like tees, bends vertical / horizontal shall be factory fabricated and cost of these to be included in the rate.\n600 mm width X 50 mm depth X 2.0 mm thickness | 140 | Metre | |
380 | 18.187 | Providing and fixing the following 14 SWG Hot Dip Galvanised Ladder tray (Bolted/Fabricated) along with necessary GI suspenders (not more than 1000 MM long) at equal intervals of 900 mm as directed. Including providing cost of GI supports, nuts, bolts, washers and dash fasteners as required. The installation shall be complete in all respects (All accessories like tees, bends vertical / horizontal shall be factory fabricated and cost of these to be included in the rate.\n900 mm width X 75 mm depth X 2.0 mm thickness | 100 | Metre | |
381 | 18.188 | Supplying and installing Hot Dipped Galvanised Cable Tray Cover (galvanisation thickness not less than 50 microns), in convenient sections, joined with connectors, GI Nuts, Bolts etc….. as required.\nCover for 300 mm width X 50 mm depth X 2.0 mm thickness | 300 | Metre | |
382 | 18.189 | Supplying and installing of Pre Galvanised Raceway with Cover, in convenient sections, joined with connectors, Rate inclusive of GI Suspenders & Supports, GI Nuts, Bolts etc….. as required.\n300mm width X 50 mm depth X 1.6 mm thickness for Raceways and 1.6mm for Cover | 60 | Metre | |
383 | 18.19 | Supplying and installing of Pre Galvanised Raceway with Cover, in convenient sections, joined with connectors, Rate inclusive of GI Suspenders & Supports, GI Nuts, Bolts etc….. as required.\n450mm width X 50 mm depth X 2.0 mm thickness for Raceways and 1.6mm for Cover | 45 | Metre | |
384 | 18.191 | Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories like cable divider, angles, couplers, cross, end caps etc.... conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. | 90 | Metre | |
385 | 18.192 | Fabrication and installing of Steel supports for Trays (Vertical/Horizontal) as required and as per prevailing standards with other steel works associated with electrical works completion as required as per site conditions using structural steel work (riveted, bolted or welded) in built up sections, including angle, channel, I sections, necessary nut and bolt and all required accessories including cutting, hoisting, fixing in position and applying 2 coats of zinc chromate primer and 2 coats of synthetic enamel paint of approved quality and colour as directed by engineer in charge. | 7500 | Kg | |
386 | 18.193 | SITC of recess mounted 24W(+/- 10% Tolerance) LED luminaire of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 110 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). \nMakes: Philips- RC380B LED30S-5700 G5 L60W60 PSU OD, Wipro-CRCO10R024HP57HE, Bajaj:BZRSQL 24W XE WH\nNote: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 1129 | Nos | |
387 | 18.194 | SITC of recess mounted 31W(+/- 10% Tolerance) LED luminaire of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 110 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). \nMakes: Philips: RC380B LED36S-5700 G5 L60W60 PSU OD, Wipro: CRCO10R030HP57HE, Bajaj: BZRSQL 30L XE WH OD SD\nNote: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 275 | Nos | |
388 | 18.195 | SITC of recess mounted LED Cleanroom fitting 40W(+/- 10% Tolerance) of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 80 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips-CR652B LED33S CR CW CA, Wipro LC20-551-XXX-57-XX Recess mounted Bajaj: BPRF 36W WH LED\nNote: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 49 | Nos | |
389 | 18.196 | SITC of recess mounted Downlights of 6W(+/- 10% Tolerance) LED luminaire of Die Cast Aluminium Housing, driver with minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- DN295B LED6S-5700 PSU WH, Wipro- CRDL11R008HP57, Bajaj: BGSLO SLEEK 6W WH RD.\nNote: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 322 | Nos | |
390 | 18.197 | SITC of recess mounted Downlights of 18W(+/- 10% Tolerance) LED luminaire of Die Cast Aluminium Housing, driver with minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- DN194B LED16S-5700 PSU WH S2, Wipro- CRDL11R023HP57, Bajaj: BZSLO 18W WH PRO.\nNote: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 520 | Nos | |
391 | 18.198 | SITC of Surface mounted Downlights of 15W(+/- 10% Tolerance) LED luminaire of driver with minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- SM250C LED16S- 6500 PSU WH, Wipro- LD81-131-XXX-60-SM, Bajaj: BGSLO SLEEK SURFACE 15W WH RD\nNote: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 39 | Nos | |
392 | 18.199 | SITC of LED Tube Lights of 20W(+/- 10% Tolerance) with Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia-Japan/ Cree-USA / Bridgelux-USA / Lumiled-USA / Citizen-Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- BN308C LED20S-6500 L120 PSU WH, Wipro- LL24-251-XXX-57-XX, Bajaj: BCLAB 20W\nNote: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 380 | Nos | |
393 | 18.2 | SITC of LED Tube Lights of 40W(+/- 10% Tolerance) with Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- BN308C LED40S-6500 L120 PSU WH, Wipro- LL24-541-XXX-57-XX, Bajaj: BCLAB 40W\nNote: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 25 | Nos | |
394 | 18.201 | SITC of LED Mirror Lights of 10W(+/- 10% Tolerance) with polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor >0.9,THD<10%, system efficacy greater than or equal to 80 lm, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor).\nMakes: Philips, Wipro, Bajaj.\nNote: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 34 | Nos | |
395 | 18.202 | SITC of Bulkhead of 10W(+/- 10% Tolerance) with polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor >0.9,THD<10%, system efficacy greater than or equal to 80 lm, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). \nMakes: Philips, Wipro, Bajaj.\nNote: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc. as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects. | 70 | Nos | |
396 | 18.203 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. \n1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades and resistance type regulator working on 230V/240V single phase A/C | 397 | Nos | |
397 | 18.204 | SITC of Industrial Type 400mm Sweep Exhaust fan | 5 | Nos | |
398 | 18.205 | SITC of LED Aviation Light | 1 | Nos | |
399 | 18.206 | Supply installation testing and commissioning of Octagonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 no's fixed in existing RCC foundation and junction box etc. complete 8 Meters | 6 | Each | |
400 | 18.207 | Supply installation testing and commissioning of Octagonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 no's fixed in existing RCC foundation and junction box etc. complete 8 Meters | 18 | Each | |
401 | 18.208 | Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 30 | Each | |
402 | 18.209 | Supply and installation of Plate Earthing with 1200mmx1200mmx12mm CI plate (conforming to IS:3043-1987) complete with RCC inspection chamber of size 1000x600x500mm with RCC cover, GI class B pipe of 50 mm dia extending up to middle of the plate and clamping to the plate with GI clamps and bolts, funnel having 20G GI wire mesh, identification of earth pit with yellow paint below the chamber cover, mixtures of charcoal around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. (value of earth resistance should be less than 1 ohm ). | 8 | Nos | |
403 | 18.21 | Supply of UL Listed & CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250 micron tested as per IEC 62561-2 & is provided with universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided with Heavy duty earth chamber with dimension of 300mmx 300mmx 450mm of 5000kg load bearing capacity to ensure the safety of earthing system including all accessories as required for complete installation as instructed by engineer in charge. | 6 | Nos | |
404 | 18.211 | Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant.\n50x06 Cu strips tinned at the point of contact. | 30 | Metre | |
405 | 18.212 | Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant.\n32x6 Cu strips tinned at the point of contact. | 140 | Metre | |
406 | 18.213 | Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant.\n25x6 Cu strips tinned at the point of contact. | 90 | Metre | |
407 | 18.214 | Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant.\n25x3 Cu strips tinned at the point of contact. | 30 | Metre | |
408 | 18.215 | Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant.\n50x6 Cu strips tinned at the point of contact. | 20 | Metre | |
409 | 18.216 | Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant.\n32x6 Cu strips tinned at the point of contact. | 195 | Metre | |
410 | 18.217 | Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant.\n25x6 Cu strips tinned at the point of contact. | 260 | Metre | |
411 | 18.218 | Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant.\n25x3 Cu strips tinned at the point of contact. | 60 | Metre | |
412 | 18.219 | Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant.\n20x3 Cu strips tinned at the point of contact. | 1516 | Metre | |
413 | 18.22 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. | 18 | Metre | |
414 | 18.221 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required \n3.15 mm copper conductor ( 10 SWG) | 2250 | Metre | |
415 | 18.222 | 4 meter air terminal with accessories\nProviding and fixing Air terminals as per IEC -62305 part-3 and IS 2309 16mm rod tapered to 10 mm aluminium rod 3 meter rod:\nMeets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) 101 VL 3000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. 2 no's of 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked. | 6 | Set | |
416 | 18.223 | 8mm solid aluminium round conductor:\nsupply and providing 8mm solid aluminium round conductor, meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. \nPolyamide Conductor holder with holding base for parapet/Flat roof:\nWith M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.\nWeather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance.\na) Vertical run- Down conductor | 1050 | Metre | |
417 | 18.224 | 8mm solid aluminium round conductor:\nsupply and providing 8mm solid aluminium round conductor, meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. \nPolyamide Conductor holder with holding base for parapet/Flat roof:\nWith M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.\nWeather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance.\nb) Horizontal run-Parapet application | 1450 | Metre | |
418 | 18.225 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) | 270 | Metre | |
419 | 18.226 | Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 no's of hexagonal plate. | 60 | Nos | |
420 | 18.227 | Providing and fixing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc. as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . | 48 | Nos | |
421 | 18.228 | Providing and fixing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Connectors: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). | 30 | Nos | |
422 | 18.229 | Providing and fixing of Equipotential bonding rail for outdoor use. | 24 | Nos | |
423 | 18.23 | SITC of Lightening counter - To count no of lightening strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. | 1 | Nos | |
424 | 18.231 | Providing and fixing of test joint suitable for 10mm dia copper coated solid steel round conductor with 100 microns of copper bonding (if pure copper conductor 25x3 mm solid tape also can be used) and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm. | 6 | Nos | |
425 | 18.232 | Providing of Plastic Corrosion Protection strip: Approx. 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. | 6 | Nos | |
426 | 18.233 | SITC of CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 20mm with copper coating thickness of 250micron tested as per IEC 62561-2 & is provided with universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided with Heavy duty earth chamber of dimension 300mmx 300mmx 170mm with 5000kg load bearing capacity to ensure the safety of earthing system. | 6 | Nos | |
427 | 18.234 | Supply and providing 6 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 5429/1969. | 90 | Sqm | |
428 | 18.235 | Supply and providing First Aid Box. | 2 | Nos | |
429 | 18.236 | SITC of Photoluminesent LT & HT Danger Boards of required sizes (as directed by Engineer in charge) | 8 | Nos | |
430 | 18.237 | Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision | 2 | Nos | |
431 | 18.238 | Supply & fixing Approved Electrical Scheme/ Layouts printed in 6mm thick Transparent Acrylic sheet fixed with suitable SS Studs in walls as directed by Engineer in charge. | 10 | Nos | |
432 | 18.239 | Supply and providing 6mm Thick MS chequered plate including cutting, welding, painting etc. as required for cable duct covering etc. | 100 | Sqm | |
433 | 18.24 | Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand for 2 no's of fire buckets, or , duly painted over a coat of primer. | 2 | Set | |
434 | 18.241 | Supply of 1 pair 11 KV rubber hand gloves of approved make. | 3 | Pair | |
435 | 18.242 | Supply and providing 12 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 11 kV dielectric strength conforming to IS 5429/1969 | 20 | Sqm | |
436 | 19 | FIRE FIGHTING WORKS | |||
437 | 19.001 | MAIN PUMP - ELECTRICAL\nSupply, installation, testing and commissioning of Horizontal End Suction Fire Hydrant Pump Set: Electrical Driven, Capacity: 2280 LPM at 90Mtr Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal coupled to High Efficient, IE-3 Rated, Squirrel Gauge Induction Electric Motor, 100HP, 3Ph, 3000 RPM, TEFC, complete with all civil works, M.S. foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement, Proper Earthing etc. Works should be Completed as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions. | 1 | Set | |
438 | 19.002 | SPRINKLER PUMP - ELECTRICAL\nSupply, installation, testing and commissioning of Horizontal End Suction Fire Sprinkler Pump Set: Electrical Driven, Capacity: 2280 LPM at 100Mtr Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal coupled to High Efficient, IE-3 Rated, Squirrel Gauge Induction Electric Motor, 100HP, 3Ph, 3000 RPM, TEFC, complete with all civil works, M.S. foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement, Proper Earthing etc. Works should be Completed as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions. | 1 | Set | |
439 | 19.003 | DIESEL PUMP\nSupply installation testing and commissioning of Stand By/Back Up Fire Pump, Horizontal, End Suction Pump, Engine Driven, suitable for Automatic operation and consisting of the following and complete in all respect as required; Capacity: 2280 LPM at 100Mtr Head conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, coupled to High Efficient Radiator Cooled Diesel Engine, 110HP, 1800/2150 RPM, and with Control Panel with Auto Starting Facility, by activation of concerned Pressure Switch and thro. 12V/24 V Electric Starter, Battery with adequate rating and with Battery Charger, Battery Leads, Diesel Tank for 6 hrs operation, exhaust pipe extended up to 2 mtr outside pump house, duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, complete with all civil works, M.S. foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, and all other necessary fixing accessories,Proper Earthing all as per Technical Specifications. | 1 | Set | |
440 | 19.004 | EXHAUST PIPES\nSupplying and fixing exhaust gas piping of suitable dia matching the Diesel Fire pump, welded black M.S 'B' class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to engine and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust. | 60 | Mtr | |
441 | 19.005 | JOCKEY PUMP\nSupply, installation, testing and commissioning of Jockey Pump: Electrical Driven, Capacity: 180 LPM at 105 Mtr Head, Vertical Multi Stage Inline Pump with S.S Impeller, Mechanical Seal, and with High Efficient Squirrel Gauge Induction Motor, 7.5HP, 3000 RPM, TEFC, complete with foundation, foundation bolts, anti vibration pad, and all other necessary fixing accessories. The Price for Pump Set shall be inclusive of connected Power and Control Cabling / Wiring work in / thro. heavy duty screwed steel Conduits / Powder Coated M.S. Tray and proper Earthing of Electric Motors, all as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions. | 2 | Set | |
442 | 19.006 | MOTOR CONTROL PANEL\nSupply, fixing, testing and commissioning of Fire Pump Panel for Main Fire Pumps, Sprinkler pump & Jockey Pump, complete as per Technical Specifications and as detailed below. Fabricate, supply, convey, install, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated Control Panel, as per IS: 8623 (with latest amendments) fabricated with 2 mm/14gauge thick CRCA sheet as per approved design and requirement, IP: 54 protection, complete with Main Isolator, Bus Bar Chamber, Volt Meter, Ammeter, Individual Star-Delta Starters for Main & Sprinkler Pumps, DOL Starter for Jockey Pump, Contactors, Auxiliary Contacts, Timers, Indicating Lamps, Fuses, Auto / Manual Selector Switches for all Fire Pumps, Manual On /Off Buttons for Jockey Pump & Manual On Buttons for Main Pumps, all internal wiring etc. The price for Control Panel shall be inclusive of Control Cabling in Steel Conduits for automatic starting of Main Pumps & Automatic start and stop for Jockey Pump and Earthing of the Panel, all as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions. \n(Detailed Technical Specification Attached) | 1 | Set | |
443 | 19.007 | Supply and Laying of below sized XLPE insulated PVC sheathed Aluminium conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc\n3C x 185 sq mm | 60 | Meter | |
444 | 19.008 | Supply and Laying of below sized XLPE insulated PVC sheathed Aluminium conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc\n3C x 10 sq mm | 60 | Meter | |
445 | 19.009 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 X 185 sq. mm (57mm) | 4 | Nos | |
446 | 19.01 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. \n3 X 10 sq. mm (22mm) | 4 | Nos | |
447 | 19.011 | AIR CUSHION VESSEL\nSupplying, Installation, Testing & Commissioning of air cushion tank (air vessel) of continuous welded construction, fabricated out of atleast 8mm thick steel with dished ends, and supporting legs, Capable of carrying 15Bar Pressure, 250mm dia & 1200mm high complete with necessary air release valve, safety valve, pressure gauge, flange connection to the wet riser piping with necessary piping to meet the functional requirement of the system. | 1 | No | |
448 | 19.012 | AIR RELEASE VALVE\nSupply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including necessary accessories and connections. | 8 | No | |
449 | 19.013 | PRESSURE GAUGE\nSupply installation testing and commissioning of 4" dia. Pressure Gauge, with ISI Mark or of equivalent International Standards.Weather / Water Proof, Type with gunmetal /brass shut off cock. | 5 | No | |
450 | 19.014 | PRESSURE SWITCH\nSupply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC etc. complete as required. | 5 | No | |
451 | 19.015 | ALARM CHECK VALVE\nSupply, installation, testing and commissioning of Alarm check valve with CI Body and Clapper, torsion Spring & Nut of Stainless Steel for 6" (150mm Dia) featured with grooved seat alarm port, external by pass, and vertically installed Alarm Check Valve having Working pressure of 175psig, Flow Rate of 3000lit/min, UL Certified, should have the following accessories like Pressure gauages, Pressure Operated switches, Drain Valve, Alarm Test Units, water motor gong, retard chamber inclusive. | 1 | No | |
452 | 19.016 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n250 mm Dia | 18 | Mtrs | |
453 | 19.017 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n200 mm Dia | 30 | Mtrs | |
454 | 19.018 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n150 mm Dia | 1330 | Mtrs | |
455 | 19.019 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n100 mm Dia | 252 | Mtrs | |
456 | 19.02 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n80 mm Dia | 177 | Mtrs | |
457 | 19.021 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n65 mm Dia | 431 | Mtrs | |
458 | 19.022 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n50 mm Dia | 702 | Mtrs | |
459 | 19.023 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n40 mm Dia | 1030 | Mtrs | |
460 | 19.024 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n32 mm Dia | 916 | Mtrs | |
461 | 19.025 | ABOVE GROUND PIPING \nSupply, laying, fixing and jointing in position Mild Steel 'C' class Heavy Duty pipes with Screwed Fittings for Pipes up to 50mm dia. and Heavy Duty butt Welded Fittings for pipes above 50mm dia. conforming to IS 1239 / 3589 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc. as required including testing hydraulically to 1.5 times the working pressure painting with Two coats of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for 200mm. Suction Line for Fire Pumps shall be inclusive of Puddle Flanges, 600 x 600mm Vortex Plates inside the Water Tanks fabricated from 10mm. M.S. Plate, with approved Paint Protection, all as per Technical Specifications.\n25 mm Dia | 3405 | Mtrs | |
462 | 19.026 | Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, Gear Operated type, confirming to BS:5155 /ASTM A-536, grade 65-45-12, with Supervisory / Tamper Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n250 mm Dia | 2 | Nos | |
463 | 19.027 | Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, Gear Operated type, confirming to BS:5155 /ASTM A-536, grade 65-45-12, with Supervisory / Tamper Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n200 mm Dia | 2 | Nos | |
464 | 19.028 | Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n150 mm Dia | 30 | Nos | |
465 | 19.029 | Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n100 mm Dia | 4 | Nos | |
466 | 19.03 | Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n80 mm Dia | 11 | Nos | |
467 | 19.031 | Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n65 mm Dia | 2 | Nos | |
468 | 19.032 | Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n50 mm Dia | 17 | Nos | |
469 | 19.033 | Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. \n250 mm Dia | 2 | Nos | |
470 | 19.034 | Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. \n200 mm Dia | 3 | Nos | |
471 | 19.035 | Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. \n150 mm Dia | 2 | Nos | |
472 | 19.036 | Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. \n100 mm Dia | 1 | Nos | |
473 | 19.037 | Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. \n80 mm Dia | 1 | No | |
474 | 19.038 | Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. \n50 mm Dia | 1 | No | |
475 | 19.039 | Supply, fixing, testing and commissioning of Forged Ball Valve, PN-20 gunmetal /cast alloy, including necessary accessories and connections.\na) 25 mm Dia | 39 | Nos | |
476 | 19.04 | Supply, fixing, testing and commissioning of Forged Ball Valve, PN-20 gunmetal /cast alloy, including necessary accessories and connections.\nb) 50 mm Dia | 3 | Nos | |
477 | 19.041 | Supply, Laying, fixing, pressure testing and commissioning of Underground Fire Hydrant Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, laying in trenches, providing thrust blocks, providing higher sizes of Protective Sleeve / Pipes and RCC encasement, all as per requirement and to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting systems and bitumen based flexible wrapping, all as per Technical Specifications\na) 150 mm Dia | 650 | Mtrs | |
478 | 19.042 | Supply, Laying, fixing, pressure testing and commissioning of Underground Fire Hydrant Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, laying in trenches, providing thrust blocks, providing higher sizes of Protective Sleeve / Pipes and RCC encasement, all as per requirement and to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting systems and bitumen based flexible wrapping, all as per Technical Specifications\nb) 100 mm Dia | 20 | Mtrs | |
479 | 19.043 | Supply, Laying, fixing, pressure testing and commissioning of Underground Fire Hydrant Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, laying in trenches, providing thrust blocks, providing higher sizes of Protective Sleeve / Pipes and RCC encasement, all as per requirement and to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting systems and bitumen based flexible wrapping, all as per Technical Specifications\nc) 80 mm Dia | 190 | Mtrs | |
480 | 19.044 | Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark, Stainless Steel-304 body with 63mm. oblique instantaneous single outlet, 75mm. N.B. flanged inlet, Stainless Steel -304 spindle, complete with PVC blank cap, G.I. chain etc. | 46 | Nos | |
481 | 19.045 | Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark. | 46 | Nos | |
482 | 19.046 | Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fiber. conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg/Cm2 and Burst Pressure 38 Kg/Cm2. The Fire Hose shall be with IS: 636 Type-A marking and 63mm. dia.x15Mtr.long with pair of 63mm. male and female instantaneous couplings, Stainless steel-304, having IS: 903 mark and duly S. S. wire wounded. | 92 | Nos | |
483 | 19.047 | Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided /rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm. isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set. | 26 | Nos | |
484 | 19.048 | Supply, installation, testing and commissioning of M.S. CRCA sheet fabricated 16 SWG Fire Hydrant hose boxes suitable for storing 2 Nos.15M hoses and 1 No. Branch pipe of 63mm dia size. Boxes will be duly painted with two coats zinc primer and finish fire red colour enamel paint outside with locking arrangement for Double leaf front glass doors having 4mm thick glass, complete as per specifications. | 24 | Nos | |
485 | 19.049 | Supply and fix at site in position Weather Proof Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate Two 15m length of delivery hose and branch pipe, acrylic fronted double door with lock 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and pole for mounting, all as per requirement. | 22 | Nos | |
486 | 19.05 | Supply, installation, testing and commissioning of Fire Brigade Inlet Breeching, C.I. body, having 4 Gunmetal, 63mm. male instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 4 nos. of rubber blank caps and G.I. chains. | 2 | No | |
487 | 19.051 | Supply, installation, testing and commissioning of Fire Brigade Draw Off Outlet C.I. body, having 4 Gunmetal, 63mm. female instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 4 nos. of rubber blank caps and G.I. chains. | 1 | No | |
488 | 19.052 | Providing, fixing, testing and commissioning of Standard Coverage , Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings.\nPendant Type, 68 / 79 Degree C Rating | 1352 | Nos | |
489 | 19.053 | Providing, fixing, testing and commissioning of Standard Coverage , Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings.\nPendant Type, 93 Degree C Rating | 40 | Nos | |
490 | 19.054 | Providing, fixing, testing and commissioning of Standard Coverage , Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings.\nUpright Type, 68 Degree C Rating. | 1327 | Nos | |
491 | 19.055 | ROSETTE PLATE - Providing & Fixing 2 Piece Chrome Plated Friction Fit recessed escutcheon for pendant sprinklers, as per requirement. | 1227 | Nos | |
492 | 19.056 | Providing, Fixing, Testing and Commission Flexible Sprinkler Hose; UL Listed, FM Approved, 25mm. (1") BSP Male Inlet, 15mm. (1/2") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, length: 1500 mm, and with all connecting systems and accessories. | 1227 | Nos | |
493 | 19.057 | Providing, fixing, testing and commissioning of SLUICE VALVE with Body Ductile Iron, Disc:Ductile Iron+EPDM, PN-20, TYPE: RISING STEM SS304, Sealing Kits:Graphite, Handy Wheel: Round Plate Epoxy Coated, Ends: Flanged Ends to ANSI as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n250 mm | 3 | Nos | |
494 | 19.058 | Providing, fixing, testing and commissioning of SLUICE VALVE with Body Ductile Iron, Disc:Ductile Iron+EPDM, PN-20, TYPE: RISING STEM SS304, Sealing Kits:Graphite, Handy Wheel: Round Plate Epoxy Coated, Ends: Flanged Ends to ANSI as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n200 mm | 1 | Nos | |
495 | 19.059 | Providing, fixing, testing and commissioning of SLUICE VALVE with Body Ductile Iron, Disc:Ductile Iron+EPDM, PN-20, TYPE: RISING STEM SS304, Sealing Kits:Graphite, Handy Wheel: Round Plate Epoxy Coated, Ends: Flanged Ends to ANSI as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n150 mm | 6 | Nos | |
496 | 19.06 | Providing, fixing, testing and commissioning of SLUICE VALVE with Body Ductile Iron, Disc:Ductile Iron+EPDM, PN-20, TYPE: RISING STEM SS304, Sealing Kits:Graphite, Handy Wheel: Round Plate Epoxy Coated, Ends: Flanged Ends to ANSI as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. \n80 mm | 5 | Nos | |
497 | 19.061 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 560 | Cum | |
498 | 19.062 | 10 Loop Fire Alarm Control Panel - \nSupply, installation, testing and commissioning of 32 Bit Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad/Soft programming. The panel should be equipped with Loop Cards considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 200 analog addressable devices with minimum 125 detectors (as per design). The panel shall work in degrade mode to give a general alarm even in case of CPU failure .FACP shall have Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The FACP shall be provided with Modbus/Bacnet for integrating to Building Management System. All the FACPs shall be networked over RS485 or propreitory protocol with minimum network speed of 256 kbps on Copper wire communication. The complete FACP and all accessories including peripheral devices shall be UL Listed and FM approved. Provision for FACP integrated with alarm handling, SMS/EMail facility etc.... | 1 | Nos | |
499 | 19.063 | Supply, installation, testing and commissioning of active repeater panel. It shall be powered from the Main FACP & shall be supplied with necessary interface cards for connecting to FACP. The Panel shall have minimum 2 x 40 characters back lit LCD display with necessory battery backup for 48 hrs operation. The panel shall be UL listed and FM approved. | 1 | Nos | |
500 | 19.064 | Addressable Manual Call Point (Pull down / Break Glass Type). Addressing shall be with user friendly Rotary and dip switch/electronically addressable. The MCP shall be UL Listed and FM Approved | 41 | Nos | |
501 | 19.065 | SITC of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 2% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall adapt to its environment by utilizing a built-in microprocessor to determine its environment and choose the appropriate sensing settings for early detection and reduction in false alarm. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal/dip switch/Electronically Addressable. The detector shall be UL Listed and FM Approved.\n(a) Above ceiling | 425 | Nos | |
502 | 19.066 | SITC of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 2% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall adapt to its environment by utilizing a built-in microprocessor to determine its environment and choose the appropriate sensing settings for early detection and reduction in false alarm. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal/dip switch/Electronically Addressable. The detector shall be UL Listed and FM Approved.\n(b) Below ceiling | 613 | Nos | |
503 | 19.067 | SITC of Addressable Rate of Rise Heat Detector rated at 9.4 deg C/min. The detector shall have LED for 360 deg viewing. Addressing shall be with user friendly Rotary and dip switch/electronically addressables.The detector shall be UL Listed and FM Approved. | 5 | Nos | |
504 | 19.068 | SITC of Addressable Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 75cd flashintg at 1 Hz for visual indication. The sounder shall be UL Listed and FM approved. | 32 | Nos | |
505 | 19.069 | SITC of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal/Dip switches/Electronically Addressable. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved. | 32 | Nos | |
506 | 19.07 | SITC of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide DPDT contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal/DIP switches/Electronically Addressable. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved. | 25 | Nos | |
507 | 19.071 | SITC of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal/DIP switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved. | 32 | Nos | |
508 | 19.072 | SITC of Addressable Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved. | 62 | Nos | |
509 | 19.073 | Providing, fixing, test and commission External Power Supply Unit, 24V, 5Amps. DC, with 7Ah. Battery Back up, for sounders, sounder bases, Strobes etc, as detailed in the technical specifications. | 12 | Nos | |
510 | 19.074 | Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armored Cables with Red Colour, as per requirement and Technical Specifications. | 14460 | Mtrs | |
511 | 19.075 | Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with above 20 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System. The control cabling from flow switches to Fire Sprinkler Annunciating Panel shall be measured separately. | 24 | Nos | |
512 | 19.076 | Providing, fixing, test and commissiong of 24 Zone Simplex type talk back master control Console having zone wise selection in powder coated 16 swg CRCA sheet housing, complete with 8 to 64 zone expandable system, AC and DC meter to measure supply, push to talk facility by call/call back facilities and Mike LED display unit for location display, in built batter charger and battery space along with Amplifier, 500 W RMS Output including necessary control wires, jack ets as per specification and required. | 1 | Set. | |
513 | 19.077 | Providing, fixing, testing and commissioning of 6 Watt Wall Mounted type Talk Back System Speaker with Call Switch, in suitable and approved housing to approved colour /shade, all as per specification.\n | 24 | Nos. | |
514 | 19.078 | Providing, fixing, laying, test and commissioning 2Core x 1.5 mm2 FRLS Armoured Cables, as per Technical Specifications. | 1840 | Mtr. | |
515 | 19.079 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(a) Fire Lift sign board (12" x 4") | 18 | Nos | |
516 | 19.08 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(b) Passenger/Fire Lift sign board (12" x 4") | 36 | Nos | |
517 | 19.081 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(c) Fire Duct sign board (12" x 4") | 27 | Nos | |
518 | 19.082 | (d) SITC of Fire Exit Light, Laser type, with High Glow LED, size: 12” x 6” Size, Ceiling Mounting type with hanging clamps, on/off switch, Red/ Green Colour option, min power consumption & with 2 Hr. battery backup. | 18 | Nos | |
519 | 19.083 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(e) Electrical Duct sign board (12" x 4") | 27 | Nos | |
520 | 19.084 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(f) Main Staircase sign board (12" x 4") | 9 | Nos | |
521 | 19.085 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(g) Fire Staircase sign board (12" x 4") | 18 | Nos | |
522 | 19.086 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(h) Floor Display sign board (12" x 4") | 27 | Nos | |
523 | 19.087 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(i) Fire Assembly Point (16" x 16") | 1 | No | |
524 | 19.088 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(j) Pump Room sign board (12" x 4") | 1 | No | |
525 | 19.089 | Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners.\n(k) Fire Control Room sign board (12" x 4") | 1 | Nos | |
526 | 19.09 | Supply, installation, testing & commissioning of Portable Fire Extinguisher as per BIS 2190 and IS: 15683:2018 and with relevant ISI Stamping/Marking. ABC Dry Chemical Store Pressure Type - 4 Kg. | 88 | Nos | |
527 | 19.091 | Supply, installation, testing & commissioning of Clean Agent Modular Type Fire Extinguisher 5Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with charge of HFC Blend A, It is a blend of Hydro Fluoro Carbon and organic detossificant essence P26. The sprikler body will comprise of temperature sencitive quartsoid bulb of temperature rating of 68 deg C. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling. Fire Extinguisher manufatured as per BIS 2190 and IS: 15683:2018 and with relevant ISI Stamping/Marking. | 20 | Nos | |
528 | 19.092 | Providing and fixing 48mm thick fire resistant door for 120 minutes fire rating conforming to BS476 Part-22 & IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, made out of 1.2mm thick galanized steel sheets, double skin door shell with suitable mounting on door frame, The door frames are manufactured from 1.6mm thick galvanised steel sheet (zinc coating not less than 120 gsm/m2) sandwiching with FR insulation material in between, formed to double rebate profile of minimum size 143mmx60mm (+/-0.3mm). The frame shall have GI Anchor fastners of suitable size for fixing in the opening along with factory made template for SS Ball Bearing Hinges for fixing the fire rated shutters/doors. The door frames and doors shutter shall be powder coated with approved fire ressistant paint & Primers etc... all complete as per direction of Engineer-in-charge. | 120 | sqm. | |
529 | 19.093 | Providing and fixing fire vision panel of requierd size with clear, toughened, interlayered, non-wired, 120minutes fire ressistant glass panes of 5mm thick on sides of the door shutters including GI U beading & Ceramic tape as required | 1.5 | sqm. | |
530 | 19.094 | Providing and fixing SS Door Closure on the fire door shutters as required | 32 | Nos | |
531 | 19.095 | Providing & fixing Dead Lock with 70mm cylinder on fire door shutters as required. | 16 | Nos | |
532 | 19.096 | Providing & fixing of SS Pull Handle of 300mm in size. | 32 | Nos | |
533 | 19.097 | Providing and fixing panic bar-Single Leaf, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. | 2 | Nos. | |
534 | 19.098 | Providing and fixing panic bar-Double Leaf, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. | 14 | Nos. | |
535 | 19.099 | Supply and Fixing of load bearing Fire stop mortar CP636 or equivalent system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. <1 g/l as per LEED 2009. Firestop installation should be done by trained applicators and in accordance with manufacturer's guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemical anchoring along the length and breadh of the shaft and provide 2 layers of chicken mesh etc.,as the base for fire mortar at 65mm thickness having load bearing capacity of 200kg/sq.mtr, For shaft size more than 0.64 sqmtr proper engineering judgement needs to be submitted through the manufacturer. Applicator needs to submit complete installation report for inspection purpose. | 65 | Sqm | |
536 | 19.1 | Providing a intumescent, flexible firestop wrap strip CP 648 E for plastic pipe, insulated pipe and various non-metalic penetrations from 2" to 6" diameter. Can be used with orthogonal pipes and pipes at 45°. It is mold and mildew resistant and the performance is Class 0 according ASTM G21-96 and EN ISO 846. Highly intumescent with an expansion temperature (intumescent activation) of 320 °F (160°C) and the expansion ratio up to 1:40. FBC System Compatible. The product shall meet LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 3.1 g/l. Firestop installation should be done by trained applicators and in accordance with Manufacturer guidelines. Applicator needs to provide complete installation report for inspection purpose\nPlastic Pipe diameter of 2.5'' (CP 648-E Firestop Wrap), Min. recommended hole dia. in wall/floor: 92 mm. | 54 | Nos | |
537 | 19.101 | Providing a intumescent, flexible firestop wrap strip CP 648 E for plastic pipe, insulated pipe and various non-metalic penetrations from 2" to 6" diameter. Can be used with orthogonal pipes and pipes at 45°. It is mold and mildew resistant and the performance is Class 0 according ASTM G21-96 and EN ISO 846. Highly intumescent with an expansion temperature (intumescent activation) of 320 °F (160°C) and the expansion ratio up to 1:40. FBC System Compatible. The product shall meet LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 3.1 g/l. Firestop installation should be done by trained applicators and in accordance with Manufacturer guidelines. Applicator needs to provide complete installation report for inspection purpose\nPlastic Pipe diameter of 3'' (CP 648-E Firestop Wrap), Min. recommended hole dia. in wall/floor: 112 mm. | 27 | Nos | |
538 | 19.102 | HVAC Ducts: Providing Acrylic Firestop Sealant Hilti CP 606 in gaps between periphery of the ducts to provide minimum 2 hours fire rating when subject to the test conditions of UL 2079 standards. The product shall be age tested as per DafStb guidelines. Sealant should provide sufficient MAF, water and gas tight seal. Sealant shall also provide airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation. Sealant shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be UL listed & classified and shall bear the UL and FM approval logo on the packing. Firestop installation should be done by trained applicator and in accordance with Manufacturer guidelines. Applicator needs to provide complete installation report for inspection purpose. | 3 | Sqm | |
539 | 19.103 | Providing expanding firestop foam CP 620, with minimum 2 hours fire rating when tested in accordance with UL 1479, for horizontal openings in floors or slabs after passing service lines like cable trays or cables/cable bundles. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall carry test certificate for sound insualtion of 50 db when tested in accordance with ASTM E 90. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be UL listed & classified and shall bear the UL and FM approval logo on the packing.Firestop installation should be done by trained applicators and in accordance with Manufacturer guidelines. Applicator needs to submit complete installation report for inspection purpose. | 2.5 | Sqm | |
540 | 19.104 | SITC of 8 zone IP based, digital Voice Alarm controller expandable upto 128 zones. The voice alarm controller shall support multi channel audio and shall be able to connect directly over Ethernet (no other protocol accepted). It shall be having in-built memory of minimum 500 Mb and shall be able to broadcast the messages to any zone in the network as per the configuration. It should have functions like the audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. It shall include PTT microphone for emergency manual announcements. The voice alarm controller shall be integrated with addressable fire alarm system for zone wise evacuation at the event of an emergency. The Voice alarm controller should also have the following functions:\n . 255 Priorities\n . Time schedule broadcasts\n . Capable of amplifier redundancy\n . 8 trigger inputs/outputs\n . Hospital codes (Code Blue/Red/Pink/White etc) broadcasting (customizable as per customer). PA System Management software with one server & client licence. It should connect with upto minimum 20 controllers. Administrator can decide No. of users and define user authorities freely. It Can display all equipment status and indicate fault alarm location. It Can record and read history operation and fault logs. It Support Text-to-Speech (TTS) function. It shall support uploading of floor maps for effective management with broadcast details etc. Audio files stored on the server can be played in any zone on the system network. | 1 | Each | |
541 | 19.105 | SITC of TCP/IP based Networkable 7" touch screen paging station for selection of zones, supervision of system status, setting of scheduled broadcasts with the following functions:\n. Built-in monitoring loudspeaker\n. Detachable goose-neck microphone\n. LCD touchscreen display\n. Audio input | 2 | Each | |
542 | 19.106 | SITC of 480 W Power Amplifier Speaker Output 4~16O Low-Z output, 480W,70V(10.7O), 100V (21.7O) Frequency response of 60 Hz~15 kHz ( ± 3 dB ), S/N >80dB, Protection like - AC Fuse × 15 A AC FUSE×1, Current limiter, short circuit and thermal protection circuits. It should have D/A converter and all accessories required. | 4 | Each | |
543 | 19.107 | SITC of Metal Grille 6W Ceiling Speaker with max SPL 1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W | 194 | Nos | |
544 | 19.108 | SITC of 6W Wall mount Box Speaker with max SPL 1M/1W 96dB . Frequency response of 160Hz-20KHz. The speaker shoud have tappings at 6W/3W | 39 | Nos | |
545 | 19.109 | Speaker Cable - Supplying and drawing of 2 Core x 1.5sq.mm flexible Unarmored Speaker cable for speakers through existing PVC conduit with all acessories as required for complete installation and as instructed by engineer in charge/ consultant and making good all damages made for installation. | 6660 | Metre | |
546 | 20 | EXTRA LOW VOLTAGE WORKS | |||
547 | 20.001 | Supplying and drawn of UTP 4 pair CAT-6 LAN cable in the existing surface/recessed steel/PVC conduit as required - \n1 run of Cable | 16435 | Meter | |
548 | 20.002 | Supplying and drawn of UTP 4 pair CAT-6A LAN cable in the existing surface/recessed steel/PVC conduit as required - \n1 run of Cable | 780 | Meter | |
549 | 20.003 | Supplying, fixing testing & commissioning of CAT-6 information oultets and accessories on wall surface/recess etc complete as required. | 234 | Each | |
550 | 20.004 | Supplying, fixing testing & commissioning of CAT-6A information oultets and accessories on wall surface/recess etc complete as required. | 15 | Each | |
551 | 20.005 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. \nTelephone socket outlet | 80 | Nos | |
552 | 20.006 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. \n1 or 2 Module (75mmX75mm) | 329 | Nos | |
553 | 20.007 | Supplying and fixing of CAT-6 24 port Front Managable Straight Loaded Patch panels | 22 | Each | |
554 | 20.008 | Supplying and fixing of CAT-6A 24 port Front Managable Straight Loaded Patch panels | 3 | Each | |
555 | 20.009 | Providing and fixing 1 or 2 metre long CAT-6 UTP Patch Cords | 234 | Each | |
556 | 20.01 | Providing and fixing 1 or 2 metre long CAT-6A UTP Patch Cords | 15 | Each | |
557 | 20.011 | SITC of 42U Wall Mount Rack with power distribution unit, cable managers, fans and other accessories. | 1 | Each | |
558 | 20.012 | SITC of 15U Wall Mount Rack with power distribution unit, cable managers, fans and other accessories. | 6 | Each | |
559 | 20.013 | SITC of 09U Wall Mount Rack with power distribution unit, cable managers, fans and other accessories. | 8 | Each | |
560 | 20.014 | Supply, installation and testing commissioning of Fully Managed 24 Port CAT 6 Network Switch with minimum of 2 SFP Uplink | 15 | Nos | |
561 | 20.015 | Supply, installation and testing commissioning of Fully Managed 08 Port CAT 6 Network Switch with minimum of 2 SFP Uplink | 2 | Nos | |
562 | 20.016 | Supply, installation and testing commissioning of Fully Managed 24 Port 10GBASE CAT 6A Network Switch with minimum of 2x10G SFP Uplink | 2 | Nos | |
563 | 20.017 | Supply Installation Testing & Commissioning of Managed 24 Port Giga PoE intelligent Ethernet Switch with 370Watt PoE Power at 24 x 10/100/1000 Base-T PoE Fast Ethernet ports and with min 2SFP Giga Ports (provision for Fiber Giga connectivity) | 4 | Nos | |
564 | 20.018 | Supply Installation Testing & Commissioning of Managed 08 Port Giga PoE Intelligent Ethernet Switch with minimum of 75Watt PoE Power at 8 x 10/100/1000 Base-T PoE Fast Ethernet ports and with min 1SFP Giga Ports (provision for Fiber Giga connectivity) | 8 | Nos | |
565 | 20.019 | SITC of Fully Managable & Stackable, Layer-3 switching compactible 24 port Gigabit Ethernet Core Switch delivers 24 Hot Swappable SFP Gigabit interfaces for fibre connectivity with 10/100/1000 SFP Switch With 2 nos 10G base-T ports and 2*SFP | 1 | Nos | |
566 | 20.02 | SITC 10G SFP Module for Access Switches | 2 | Nos | |
567 | 20.021 | SITC 1G SFP Module for Access Switches | 29 | Nos | |
568 | 20.022 | SITC of 1Mtr DAC Cables | 20 | Nos | |
569 | 20.023 | SITC of POE Based Wireless-N Access Point | 10 | Nos | |
570 | 20.024 | Supply & Laying of 06 core unarmoured Multimode Optical Fibre Cable. | 1330 | Metre | |
571 | 20.025 | Supply fixing splicing Termination & commissioning of 06 Port Fully loaded LIU Rack mountable (with Pigtail) including all the accessories like, LC duplex for 6mm fibre cassette for pigtails, blanking plate for modular drawer etc... as required for the proper functioning of the system. | 14 | Nos | |
572 | 20.026 | Supply fixing splicing Termination & commissioning of High Density 96 Core Fully loaded LIU Rack mountable (with Pigtail) including all the accessories like, LC duplex for 6mm fibre cassette for pigtails, blanking plate for modular drawer etc... as required for the proper functioning of the system. | 1 | Nos | |
573 | 20.027 | SITC of LC-LC Patch Cord | 60 | Nos | |
574 | 20.028 | Supply, installation, testing & commissioning of IPABX Equipped with below configuration. \n• 100 Analogue extension & 8 Digital extension, expandable up to 128 lines. \n• PRI interface & rack mountable\n• 4 port welcome message and Auto Attendant up 4 level, Linux Based & support XML Applications.\n• Minimum 8 Nos IP/SIP Extension number\n• Operator console (24 key KTS +DSS) \nIncludes all the accessories like Connectors, Wall/Floor Mounted Racks, Cables & Jumper Wires for connectivity etc.... for its proper functioning of the system and as directed by the Engineer in charge. | 1 | Nos | |
575 | 20.029 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. \n2 Pair | 5830 | Meter | |
576 | 20.03 | SITC of 10 Pair (0.5mm) Armoured Telephone cable | 510 | Metre | |
577 | 20.031 | SITC of 20 Pair (0.5mm) Armoured Telephone cable | 530 | Metre | |
578 | 20.032 | SITC of 100 Pair (0.5mm) Armoured Telephone cable | 20 | Metre | |
579 | 20.033 | SITC of IP Telephone | 2 | Nos | |
580 | 20.034 | SITC of Analogue Telephone | 80 | Nos | |
581 | 20.035 | SITC of 20Pair Telephone Krone Module in MS Powder Coated Enclsoure with lockable arrangement | 4 | Nos | |
582 | 20.036 | SITC of 10Pair Telephone Krone Module in MS Powder Coated Enclsoure with lockable arrangement | 5 | Nos | |
583 | 20.037 | SITC of 120Pair Telephone Krone Module in MS Powder Coated Enclsoure with lockable arrangement | 1 | Nos | |
584 | 20.038 | Supply, Installation, Testing Commissioning of 2MP IR Bullet camera (Detailed Technical Specification Attached) | 12 | Nos | |
585 | 20.039 | Supply, Installation, Testing Commissioning of 2MP IR Dome camera (Detailed Technical Specification Attached) | 46 | Nos | |
586 | 20.04 | Supply, Installation, Testing Commissioning of 32 Channel NVR (Detailed Technical Specification Attached) | 2 | Nos | |
587 | 20.041 | Supply, Installation, Testing Commissioning of Workstation (Detailed Technical Specification Attached) | 1 | Nos | |
588 | 20.042 | Supply, installation, Testing and Commissioing of 40'' Flat Screen HD Professional LED(24X7) with Interfaces include HDMI, DVI, D-sub, Component and Composite input as well as RS-232C and RJ45 for extensive connectivity, remote control and wall mount unit / floor stand complete with making connections etc complete as reqd. | 2 | Nos | |
589 | 20.043 | SITC of 6TB Survillance Hard Disk Drive. | 6 | Nos | |
590 | 21 | LIFT WORKS | |||
591 | 21.001 | LIFT-1,3,4,5\nDesign, manufacture, supply, installation at site, testing, commissioning and maintain (during guarantee period of 36 months from the date of commissioning) Passenger cum Bed Lift to carry 26 (Twenty Six) persons capacity of load 1768 Kgs with a minimum speed of 1.5 metre per second as per the detailed specification attached including all necessary safety features and in accordance with theparticulars of lift service requirement and technical specifications etc. complete.\n8 Stops and 8 openings. \n(Shaft Size available - 3500 mm x 2500 mm)\nNote :The rate shall include obtaining necessary initial and final approval from Kerala State electrical Inspectorate for lift installation and operation before handing over the entire lift installation. | 4 | Nos | |
592 | 21.002 | LIFT-2 & 6\nDesign, manufacture, supply, installation at site, testing, Commissioning and maintain (during guarantee period of 36 months from the date of commissioning) Goods cum Bed Lift of 2Ton capacity with a minimum speed of 1.0 metre per second and as per the detailed specification attached including all necessary safety features and in accordance with the particulars of lift service requirement and technical specifications etc. complete. \n8 Stops and 8 openings. \n(Shaft Size available - 3500 mmx 2500 mm)\nNote :The rate shall include obtaining necessary initial and final approval from Kerala State electrical Inspectorate for lift installation and operation before handing over the entire lift installation | 2 | Nos | |
593 | 22 | MEDICAL GAS PIPELINE SYSTEM | |||
594 | 22.001 | SITC of Oxygen Manifold - 2 banks x 10 cylinders | 1 | Set | |
595 | 22.002 | SITC of Fully Automatic Oxygen Control Panel with minimum flow rate of 1500 LPM | 1 | Set | |
596 | 22.003 | SITC of Emergency Oxygen Manifold - 2 banks x 5cylinders | 1 | Set | |
597 | 22.004 | SITC of Oxygen Flowmeters with humidifier bottle | 189 | Nos | |
598 | 22.005 | SITC of Nitrous Oxide Manifold - 2 banks x 1 cylinders | 1 | Set | |
599 | 22.006 | SITC of Fully automatic Gas Control Panel for Nitrous Oxide with a minimum flow rate of 500 LPM | 1 | Set | |
600 | 22.007 | SITC of Emergency Nitrous Oxide Manifold - 1 bank x 1 cylinders | 1 | Set | |
601 | 22.008 | SITC of Carbon Dioxide Manifold - 2 banks x 1 cylinders | 1 | Set | |
602 | 22.009 | SITC of Fully automatic Gas Control Panel for Carbon Di Oxide with minimum flow rate of 300 LPM | 1 | Set | |
603 | 22.01 | SITC of Emergency Carbon Dioxide Manifold - 1 bank x 1cylinders | 1 | Set | |
604 | 22.011 | SITC of Compressed air plant system having minimum free air delivery of 1500 LPM with complete accessories as mentioned in technical specifications. | 1 | Each | |
605 | 22.012 | SITC of vacuum plant system having minimum free air aspirated of 2500 LPM at 450 mmHg with complete accessories as mentioned in technical specifications. | 1 | Each | |
606 | 22.013 | SITC of Ward Vacuum Units | 178 | No. | |
607 | 22.014 | SITC of Theatre Vacuum Units | 11 | No. | |
608 | 22.015 | SITC of Electrical Panel for Air Compressor & Vacuum Pump | 1 | No. | |
609 | 22.016 | SITC of ICU Terminal Units - Imported - O2 | 114 | No | |
610 | 22.017 | SITC of ICU Terminal Units - Imported - Air | 57 | No | |
611 | 22.018 | SITC of ICU Terminal Units - Imported - VAC | 112 | No | |
612 | 22.019 | SITC of Ward Terminal Units - Indigenous - O2 | 115 | No | |
613 | 22.02 | SITC of Ward Terminal Units - Indigenous - N2O | 2 | No | |
614 | 22.021 | SITC of Ward Terminal Units - Indigenous - Air | 2 | No | |
615 | 22.022 | SITC of Ward Terminal Units - Indigenous - Air 7 bar | 2 | No | |
616 | 22.023 | SITC of Ward Terminal Units - Indigenous - Vac | 115 | No | |
617 | 22.024 | SITC of Matching Probe - O2 | 229 | No | |
618 | 22.025 | SITC of Matching Probe - N2O | 2 | No | |
619 | 22.026 | SITC of Matching Probe - Air | 59 | No | |
620 | 22.027 | SITC of Matching Probe - Air 7 bar | 2 | No | |
621 | 22.028 | SITC of Matching Probe - VAC | 227 | No | |
622 | 22.029 | SITC of Master Plant Alarm Panel (post source), BMS compatible, | 1 | No | |
623 | 22.03 | SITC of Area Valve Service Units with Alarm Systems - 6 Services | 11 | No. | |
624 | 22.031 | SITC of Area Valve Service Units with Alarm Systems - 4 Services | 9 | No. | |
625 | 22.032 | SITC of Area Valve Service Units with Alarm Systems - 3 Services | 1 | No. | |
626 | 22.033 | SITC of Area Valve Service Units with Alarm Systems - 2 Services | 7 | No. | |
627 | 22.034 | SITC of Copper pipe - per mtr. - 12mm | 1090 | Mtrs | |
628 | 22.035 | SITC of Copper pipe - per mtr. - 15mm | 2003 | Mtrs | |
629 | 22.036 | SITC of Copper pipe - per mtr. - 22mm | 2420 | Mtrs | |
630 | 22.037 | SITC of Copper pipe - per mtr. - 28mm | 857 | Mtrs | |
631 | 22.038 | SITC of Copper pipe - per mtr. - 35mm | 275 | Mtrs | |
632 | 22.039 | SITC of Copper pipe - per mtr. - 42mm | 68 | Mtrs | |
633 | 22.04 | SITC of Copper pipe - per mtr. - 54mm | 160 | Mtrs | |
634 | 22.041 | SITC of Copper pipe - per mtr. - 76mm | 83 | Mtrs | |
635 | 22.042 | SITC of Copper pipe - per mtr. - 108mm | 1 | Mtrs | |
636 | 22.043 | SITC of Ball Valves - 15mm | 16 | No. | |
637 | 22.044 | SITC of Ball Valves - 22mm | 13 | No. | |
638 | 22.045 | SITC of Ball Valves - 28mm | 7 | No. | |
639 | 22.046 | SITC of Ball Valves - 35mm | 9 | No. | |
640 | 22.047 | SITC of Ball Valves - 42mm | 2 | No. | |
641 | 22.048 | SITC of Ball Valves - 54mm | 2 | No. | |
642 | 22.049 | SITC of Ball Valves - 76mm | 1 | No | |
643 | 22.05 | SITC of Ball Valves - 108mm | 1 | No | |
644 | 22.051 | SITC of Bed Head Units - 1000 mm for Wards | 9 | No. | |
645 | 22.052 | SITC of Bed Head Units - 1500 mm for ICU Category. | 57 | No. | |
646 | 22.053 | SITC of Bed Head Panel - Running Meter | 190 | Rm | |
647 | 22.054 | SITC of Rigid Pendent | 1 | No. | |
648 | 23 | HEATING VENTILATION AND AIR CONDITIONING WORKS | |||
649 | 23.001 | Supply at site including local transport with full cover insurance, fire or any other contigencies, unload, store, handle, erect, balance, test and commission the entire water chilling plant as per specifications including all accessories as specified for water chilling plant. WATER COOLED SCREW CHILLER - (R-134A/410) EACH WITH SEMI SEALED/SEALED, SINGLE/MULTIPLE COMPRESSOR OF MINIMUM CAPACITY 110 TR.\nMinimum Overall Chiller efficiency offered shall have COP = 4.9 AS PER ECBC / ASHRAE / ARI 550/590 (Detailed Technical Specification Attached) | 3 | Nos | |
650 | 23.002 | Supply, installation, testing & commissioning the chilled water primary pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required\nEndsuction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications:\nCapacity : 264 USgpm, 1440rpm (1 Stand by)\nHead : 45 feet\nMotor : 5 H.P (suggested) - IE 3 | 4 | Nos. | |
651 | 23.003 | Supply, installation, testing & commissioning the chilled water secondary pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required\nEndsuction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications:\nCapacity : 264 USgpm, 1440rpm (1 Stand by)\nHead : 90 feet\nMotor : 10 H.P (suggested) - IE 3 | 4 | Nos. | |
652 | 23.004 | Supply, Installation, Testing & commissioning of Variable Frequency Drive complete with VSPS control panel (IP 55 if panel is to be installed under open air, IP 20 if VFD is to be installed with panel enclosure) consisting of adjustable frequency drive (AFD) for each pump, one dedicated microprocessor based pump logic controller per zone housed within this enclosure panel with parallel pumping software duly down loaded and single / multiple differential pressure sensor / transmitters as per the site requirement. The entire system along with secondary pumps as described above must be sourced from single manufacturer only, to ensure unit responsibility. The VFD should be incorporated with RFI (radio frequency interface) filters which can control THDi [Total Harmonic Distortion Current] below 5%, auto bypass starter compatible to the third party bms. | 1 | Set | |
653 | 23.005 | Supply, Installation, testing & commsssioning the condenser water pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required\nEndsuction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications:\nCapacity : 440 USgpm, 1440rpm (1 Stand by)\nHead : 70 feet\nMotor : 15 H.P (suggested) - IE 3 | 4 | Nos. | |
654 | 23.006 | Supply, Installation, testing & commissioning the cooling towers as per specification including all accessories as specified and as required. COOLING TOWERS of actual capacity complete in all respects as per technical specifications and equipment schedule complete with FRP casing, FRP fan cylinder, PVC louvers, PVC drift eliminator polypropelene nozzles, drive assembly, HDG fan guard/bird screen, non-clogging nozzle type water distribution system. PVC fill, aluminium ladder with railings, make up water, quick fill and drain over flow connections with valves & fittings etc. as per specifications.\nIncluding R.C.C foundation along with PCC/RCC sub base, fixing with bolts and nuts and finishing the slabs or any opening etc.\n110 TR - CTI/JCI approved induced draft, cross flow cooling tower with vertical air discharge.\nEWT = 97.5 degree F\nLWT = 90 degree F\nWET bulb = 82 degree F\nFlow rate = 440 USgpm \nMotor suggested - 5 HP | 3 | Nos. | |
655 | 23.007 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n30 TR, 12000 cfm, 24 sqft./ 4 row.\nDouble Skin Floor mounted Horizontal AHU with mixing Box | 1 | No | |
656 | 23.008 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n16 TR, 7250 cfm, 14.4 sqft./ 4 row.\nDouble Skin Floor mounted Horizontal AHU with mixing Box, 2 x 3 KW Heater | 2 | No | |
657 | 23.009 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n10 TR 4000 CFM 8 sqft / 4 row.\nDouble Skin Floor mounted Horizontal AHU with mixing Box | 1 | No | |
658 | 23.01 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n9TR 3600 CFM 7.2 sqft / 6 row.\nDouble Skin Ceiling suspended AHU with mixing Box, including heater of 2 x 3kW | 1 | No | |
659 | 23.011 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n7TR 2800 CFM 5.6 sqft / 6 row.\nDouble Skin Ceiling suspended AHU with mixing Box, including heater of 2 x 3kW | 1 | No | |
660 | 23.012 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n5 TR 2000 CFM 4 sqft/ 4 row. \nDouble Skin Floor mounted Horizontal AHU with mixing Box | 1 | No | |
661 | 23.013 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n26 TR, 10400 cfm, 20.8 sqft./ 4row.\nDouble Skin Floor mounted Horizontal AHU with fine filter, mixing Box | 1 | No | |
662 | 23.014 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n10 TR 4000 CFM 8.8 sqft./ 4 row. \nDouble Skin Floor mounted Horizontal AHU with fine filter, mixing Box | 2 | No | |
663 | 23.015 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n9TR 3600 CFM 7.2 sqft./ 4 row. \nDouble Skin Floor mounted Horizontal AHU with fine filter, mixing Box | 1 | No | |
664 | 23.016 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n8TR 3200 CFM 6.4 sqft./ 4 row. \nDouble Skin Floor mounted Horizontal AHU with fine filter, mixing Box | 2 | No | |
665 | 23.017 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n4 TR 1600 CFM 3.2 sqft./ 4 row.\nDouble Skin Floor mounted Horizontal AHU with fine filter, mixing Box | 2 | No | |
666 | 23.018 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n15 TR 6000 CFM 12 sq.ft./ 4 row. \nDouble Skin ceiling suspended AHU | 1 | No | |
667 | 23.019 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n12 TR 4800 CFM 7.2sq.ft./ 4 row. \nDouble Skin ceiling suspended AHU | 1 | No | |
668 | 23.02 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \n\nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n4 TR 1800 CFM 3.6 sq.ft./ 4 row. \nDouble Skin ceiling suspended AHU | 1 | No | |
669 | 23.021 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n3 TR, 1005 cfm, 2.01 sqft./ 6 Row\nDouble skin ceiling suspended AHU with fine filter, mixing box. | 1 | No | |
670 | 23.022 | Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. \nThermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same\nNotes: Fine filter efficiency 99.9% down to 5 micron.\nExternal Static Pressure for: \nOperation theater AHU's 100 mm Static\nCathlab, CT/MRI- 65 mm Static\nAHU's with fine filters - 55 mm Static\nall other AHU's - 50 mm Static\n7 TR, 3200 cfm, 6.4 sqft./ 8 Row - OT\nDouble Skin Floor mounted Horizontal AHU with mixing box, 10 micron pre filters , 5 micron fine filters, heater capacity 2 x 3KW, Thermal break | 11 | No | |
671 | 23.023 | Supply at site, including, local transport, unload, store, handle, erect, balance and commission of the entire HRW as per specifications including all accessories as specified and as required\nSummer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F\nReturn Air condition: DBT- 75 Deg F , RH– 55%\nSupply Fan Static - 60 to 70 mm WG\nReturn fan - 40 mm to 60 mm WG\nEfficiency 80- 85%\n\nTFA \nTFA - 37 TR AHU, 12.8 sq.ft./ 8 Row coil with 6400 CFM Supply fan, 5750 cfm Return fan with Heater | 1 | No | |
672 | 23.024 | Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)\n0.75 TR Hideway FCU | 8 | No | |
673 | 23.025 | Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)\n1 TR Hideway FCU | 48 | No | |
674 | 23.026 | Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)\n1.25 TR Hideway FCU | 12 | No | |
675 | 23.027 | Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)\n1.5 TR Hideway FCU | 30 | No | |
676 | 23.028 | Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)\n2 TR Hideway FCU | 8 | No | |
677 | 23.029 | Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)\n2.5 TR Hideway FCU | 1 | No | |
678 | 23.03 | Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)\n3 TR Hideway FCU | 3 | No | |
679 | 23.031 | SITC of 1.5 TR Chilled Water Hiwall Unit | 6 | No | |
680 | 23.032 | SITC of 1 TR Chilled Water Hiwall Unit | 4 | No | |
681 | 23.033 | Supply, installing, testing and commissioning of following cassette units with drain pump & fresh air provision as per specification including all accessories as specified and as required\n1 TR one way cassette unit | 1 | No | |
682 | 23.034 | Supply, installing, testing and commissioning of following cassette units with drain pump & fresh air provision as per specification including all accessories as specified and as required\n1.5 TR one way cassette unit | 1 | No | |
683 | 23.035 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.200 mm dia. | 160 | Meter | |
684 | 23.036 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.150 mm dia. | 5 | Meter | |
685 | 23.037 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.125 mm dia. | 40 | Meter | |
686 | 23.038 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.100 mm dia. | 230 | Meter | |
687 | 23.039 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.80 mm dia. | 85 | Meter | |
688 | 23.04 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.65 mm dia. | 200 | Meter | |
689 | 23.041 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.50 mm dia. | 200 | Meter | |
690 | 23.042 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.40 mm dia. | 510 | Meter | |
691 | 23.043 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.32 mm dia. | 450 | Meter | |
692 | 23.044 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.25 mm dia. | 635 | Meter | |
693 | 23.045 | Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications.\nUndergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same.20 mm dia. | 1830 | Meter | |
694 | 23.046 | Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection.200 mm dia. | 95 | Meter | |
695 | 23.047 | Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection.100 mm dia. | 75 | Meter | |
696 | 23.048 | DRAIN WATER PIPING:\nSupply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same.\n32 mm dia. PVC | 150 | Meter | |
697 | 23.049 | DRAIN WATER PIPING:\nSupply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same.\n20 mm dia. PVC | 300 | Meter | |
698 | 23.05 | Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating.200 mm dia. | 7 | Nos | |
699 | 23.051 | Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating.150 mm dia. | 1 | Nos | |
700 | 23.052 | Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating.125 mm dia. | 4 | Nos | |
701 | 23.053 | Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating.100 mm dia. | 28 | Nos | |
702 | 23.054 | Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating.80 mm dia. | 2 | Nos | |
703 | 23.055 | Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating.65 mm dia. | 14 | Nos | |
704 | 23.056 | Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating.50 mm dia. | 6 | Nos | |
705 | 23.057 | Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating.40 mm dia. | 28 | Nos | |
706 | 23.058 | Supplying, fixing, testing and commissioning of following Ball valves and Drain valves for AHUs, plant room, shaft riser & chilled water piping adequately supported as per specifications. 32 mm dia | 30 | Nos | |
707 | 23.059 | Supplying, fixing, testing and commissioning of following Ball valves and Drain valves for AHUs, plant room, shaft riser & chilled water piping adequately supported as per specifications. 25 mm dia | 33 | Nos | |
708 | 23.06 | Supplying, fixing, testing and commissioning of following Ball valves and Drain valves for AHUs, plant room, shaft riser & chilled water piping adequately supported as per specifications. 20 mm dia | 2 | Nos | |
709 | 23.061 | Supply, installation, testing & commissioning of the following non return valves as per the specifications and as required. Non Return valves up to 65mm size shall be of gun metal with screwed female ends. Valves of 65mm and above shall be of CI with flanged ends. PN 16 pressure rating, EPDM seal.\nNon- Return Valve of size:- 100 mm dia | 8 | Nos | |
710 | 23.062 | BALANCING VALVE WITH PROVISION FOR FLOW MEASURMENT:\nSupply, installation, testing & commissioning of Balancing valve with built in measuring facility, C.I Body with EPDM seal, long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water as specified. Balancing Valve with 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections; Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/-, necessary insulation as per specification\nBalancing valve with built in measuring facility 100 mm dia | 3 | Nos | |
711 | 23.063 | SUCTION GUIDE with strainer:\nSupply, installation, testing & commissioning of the following suction guides as per the specifications and as required.\nSize: 100 mm dia. | 8 | Nos | |
712 | 23.064 | Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 65 mm dia | 3 | Nos | |
713 | 23.065 | Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 50 mm dia | 4 | Nos | |
714 | 23.066 | Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 40 mm dia | 8 | Nos | |
715 | 23.067 | Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 32 mm dia | 12 | Nos | |
716 | 23.068 | Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 25 mm dia | 4 | Nos | |
717 | 23.069 | PRESSURE GAUGE - For chiller, pumps, AHU:\nProviding and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required | 84 | Nos | |
718 | 23.07 | THERMOMETERS - For chiller, pumps, AHU: \nSupply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification | 84 | Nos | |
719 | 23.071 | Supply, installation, testing & commissioning of differential pressure switch as per the specifications and as required. | 3 | Nos | |
720 | 23.072 | Supply, installation, testing & commissioning of the following motorized cut off valves as per the specifications and as required. Cl Body, minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.\nSize: 100 mm dia. | 3 | Nos | |
721 | 23.073 | 500 L Pressurized Tank:\nDesign, supply, installation, testing and commissioning of Pressurised chilled water expansion tank with insulation, Make up connection for closed loop system along with necessary pneumatic devices and accessories and MS 'C' section supports in order to keep chilled water under pressure. The tank shall be precharged steel tank with replacable heavy duty butyl rubber bladder. The tank shall have 50mm system connection and 20mm drain and charging valve connection to facilitate on-site charging of tank. The tank shall be fitted with lifting rings and floor mounting skirt for vertical installation. The tank shall be constructed according to section 8 of ASME boiler and pressure vessel code and stamped 125psi working pressure.The contractor shall submit calculation regarding the above data. Pumps shall be of N+1 configuration. including with control wiring | 1 | Nos | |
722 | 23.074 | Supply, installation, testing & commissioning of a common air separator on the chilled water return line located at the pump suction and suitable for Secondary pump water flow; the separator shall be complete with high capacity air vent, flanges, service valve, non return valve, isolation butterfly valve for makeup water inlet.\nCapacity suitable for 792 USGPM and 200mm NB CHW Header line | 1 | Nos | |
723 | 23.075 | AUTO AIR VENTS including Ball Valves:\nSupply & install of airvents / purge valves including 15mm Ball Valves at the highest points in chilled water piping complete each floor with pipes nipple welded to pipe, hex nipple, socket, U-pipe connection at outlet of air vent etc. as required. | 35 | Nos | |
724 | 23.076 | Supply and fix flexible connections with control rods for pumps and chiller.\nSize: 100 mm dia. | 22 | Nos | |
725 | 23.077 | Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification65 mm dia. | 3 | Nos | |
726 | 23.078 | Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification50 mm dia. | 4 | Nos | |
727 | 23.079 | Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification40 mm dia. | 8 | Nos | |
728 | 23.08 | Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification32 mm dia. | 12 | Nos | |
729 | 23.081 | Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification25 mm dia. | 4 | Nos | |
730 | 23.082 | Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same.200 mm dia. | 75 | Meter | |
731 | 23.083 | Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same.125 mm dia. | 45 | Meter | |
732 | 23.084 | Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same.100 mm dia. For equalizer line | 15 | Meter | |
733 | 23.085 | Supply, installation, testing & commissioning of the following butterfly valves as per the specifications and as required.\nBUTTERFLY VALVE (MANUAL): Size- 125 mm | 20 | No. | |
734 | 23.086 | Supply, installation, testing & commissioning of the following butterfly valves as per the specifications and as required.- For equalizer line\nBUTTERFLY VALVE (MANUAL): Size- 100 mm | 3 | No. | |
735 | 23.087 | Supplying, fixing, testing and commissioning of following non return valves, in the condenser water piping and adequately supported as per specifications. \nNon- Return Valve of 125 mm dia | 4 | No. | |
736 | 23.088 | Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required\nSize: 125 mm dia | 4 | No. | |
737 | 23.089 | Supply and fix flexible connections with control rods for pumps, cooling tower & condenser. \nSize: 125 mm NB | 14 | No. | |
738 | 23.09 | Supply, installation, testing & commissioning of Balancing Valve, with built in measuring facility with C.I Body, 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections;Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/- \nSize: 125 mm NB | 6 | No. | |
739 | 23.091 | Supply, installation, testing and commissioning of 4" Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification | 14 | No. | |
740 | 23.092 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required | 14 | No. | |
741 | 23.093 | Supply, installation, testing & commissioning of differential pressure switch as per the specifications and as required. | 3 | No. | |
742 | 23.094 | Supply, installation, testing & commissioning of the following motorized cut off valves as per the specifications and as required. Cl Body, Nylon coated DI disc, EPDM seal, minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.\nSize: 125 mm dia | 6 | No. | |
743 | 23.095 | Supply, fabricate, handle, erect, balancing and commissioning factory fabricated GSS ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces, slip on flanges, rubber gaskets, elbows, hangers, supports etc. etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs.Thickness 0.63 mm GSS sheet | 1900 | Sq.m | |
744 | 23.096 | Supply, fabricate, handle, erect, balancing and commissioning factory fabricated GSS ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces, slip on flanges, rubber gaskets, elbows, hangers, supports etc. etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs.Thickness 0.80 mm GSS sheet | 1025 | Sq.m | |
745 | 23.097 | Supply, fabricate, handle, erect, balancing and commissioning factory fabricated GSS ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces, slip on flanges, rubber gaskets, elbows, hangers, supports etc. etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs.Thickness 1.00 mm GSS sheet | 225 | Sq.m | |
746 | 23.098 | SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major & Minor OT's, CT/MRI, etc.Thickness 0.80 mm Al. Sheet ducting | 1175 | Sq.m | |
747 | 23.099 | SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major & Minor OT's, CT/MRI, etc.Thickness 1.00 mm Al. Sheet ducting | 585 | Sq.m | |
748 | 23.1 | Supply installing, testing and commissioning of fine filters of efficiency 99.9% down to 5 microns in filter plenum in suitable frame work for MRI/CT:\nFine filters - as per dwg, 7250 cfm | 1 | Lot | |
749 | 23.101 | TOTAL HEPA FILTRATION AREA – 5.4 Sq.mt:\nSupply installing, testing and commissioning of (Factory Fabricated) HEPA filters of efficiency 99.9% down to 0.3 microns in filter plenum of 18 Gauge with rubber Gaskets In SS suitable frame work with 70% perforated grille \nUltra Clean Ventilation arrangement of A/C inside the clean room comprising of SS supply plenum including the 1.5" flanges on all sides., material SS 304, 0.8mm, 2B finish. HEPA filters 0.3microns, efficiency 99.97% EU13 Sizes of: 1200 x 900 x 150mm - 4 Nos, 900 x 600 x 150mm- 2 Nos. The HEPA filters will be fixed to the plenum using M6 SS rode, 304 Q type SS bolts and nuts). SS perforated sheets Mat finish.\nHepa filters (550 cfm x 4 nos.+ 500 cfm x 2 Nos.) | 11 | Set | |
750 | 23.102 | Supplying and Fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. | 4.5 | Sq.m | |
751 | 23.103 | Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. | 6 | Sq.m | |
752 | 23.104 | Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600\nSD: 375×375 | 400 | Nos | |
753 | 23.105 | Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600\nSD: 450×450 | 4 | Nos | |
754 | 23.106 | Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600\nSD: 375×375 | 400 | Nos | |
755 | 23.107 | Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600\nSD: 450×450 | 4 | Nos | |
756 | 23.108 | Supply installing, testing and commissioning of perforated aluminium grille for return with VCD and 10 Micron Filter in OT | 32 | Sq.m | |
757 | 23.109 | Supply, Fabrication, installation and testing of following size insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification.\n350 mm dia | 650 | Meter | |
758 | 23.11 | SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes\n450 X 450 X 450H | 400 | Nos | |
759 | 23.111 | SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes\n600 X 600 X 450H | 4 | Nos | |
760 | 23.112 | SITC of Factory made fresh air dampers with louvers and control lever, filter etc as required. (as per drawing) | 49 | Nos | |
761 | 23.113 | SITC of Factory made fresh air dampers having 20 micron filter with louvers and control lever. (for OT as per drawing) | 1 | Nos | |
762 | 23.114 | Supply, fix, balance and commissioning of louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, brass bushings complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges, fixing arrangement etc, as per specifications.\nAl. volume control duct damper | 16 | sq.m | |
763 | 23.115 | Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link & microswitch to shut of corresponding AHU (including control cable.) | 12 | sq.m | |
764 | 23.116 | SITC of VAVs of following CFMs for supply air in rectangular ducts including thermostat and controls. Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge.\nVAV - 1350 cfm | 1 | Nos | |
765 | 23.117 | SITC of VAVs of following CFMs for supply air in rectangular ducts including thermostat and controls. Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge.\nVAV - 1450 cfm | 1 | Nos | |
766 | 23.118 | Thermal insulation:\nSupply & fixing of 8 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3 | 2500 | Sq.m | |
767 | 23.119 | Acoustic insulation:\nSupply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140-180kg/m3 | 700 | Sq.m | |
768 | 23.12 | Non ac area duct insulation:\nSupply & fixing of 19 mm thick Class O nitrile rubber insulation with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3 | 1600 | Sq.m | |
769 | 23.121 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 80 cfm Exhaust blower | 7 | Nos | |
770 | 23.122 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 100 cfm Exhaust blower | 7 | Nos | |
771 | 23.123 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 150 cfm Exhaust blower | 15 | Nos | |
772 | 23.124 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 200 cfm Exhaust blower | 8 | Nos | |
773 | 23.125 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 250 cfm Exhaust blower | 1 | Nos | |
774 | 23.126 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 300 cfm Exhaust blower | 4 | Nos | |
775 | 23.127 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 350 cfm Exhaust blower | 14 | Nos | |
776 | 23.128 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 400 cfm Exhaust blower | 2 | Nos | |
777 | 23.129 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 450 cfm Exhaust blower | 1 | Nos | |
778 | 23.13 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 500 cfm Exhaust blower | 1 | Nos | |
779 | 23.131 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 650 cfm Exhaust blower | 2 | Nos | |
780 | 23.132 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 750 cfm Exhaust blower | 3 | Nos | |
781 | 23.133 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 800 cfm Exhaust blower | 1 | Nos | |
782 | 23.134 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 850 cfm Exhaust blower | 2 | Nos | |
783 | 23.135 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 900 cfm Fresh Air blower | 1 | Nos | |
784 | 23.136 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 1000 cfm Exhaust blower | 5 | Nos | |
785 | 23.137 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 1150 cfm Exhaust blower | 1 | Nos | |
786 | 23.138 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 1250 cfm Exhaust blower | 1 | Nos | |
787 | 23.139 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 1300 cfm Exhaust blower | 1 | Nos | |
788 | 23.14 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 1400 cfm Exhaust blower | 1 | Nos | |
789 | 23.141 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 1500 cfm Exhaust blower | 2 | Nos | |
790 | 23.142 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 1600 cfm Exhaust blower | 1 | Nos | |
791 | 23.143 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 1700 Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; cfm Exhaust blower | 2 | Nos | |
792 | 23.144 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 2100 cfm Exhaust blower | 1 | Nos | |
793 | 23.145 | Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen; 2700 cfm Exhaust blower | 3 | Nos | |
794 | 23.146 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006.\nThickness 0.63mm Sheet | 700 | Sq.m | |
795 | 23.147 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006.\nThickness 0.80mm Sheet | 10 | Sq.m | |
796 | 23.148 | Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification.\nSize: 100mm dia. | 520 | Meter | |
797 | 23.149 | Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers. Design to be approved (material : Aluminium)\nReturn air grille/diffuser with vcd | 8 | Sq.m | |
798 | 23.15 | Acoustic Lining of AHU Rooms/boxing without Mixing Box /Boxing Insulation for Ceiling suspended AHU\nSupply & fixing of 15 mm thick acoustic nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 140-180kg/m3 | 100 | Sq.m | |
799 | 23.151 | UNDER DECK INSULATION - FOR ICU, OPERATION THEATRE, MRI, CT, ISOLATION ROOMS: \nSupply & fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3 | 1700 | Sq.m | |
800 | 23.152 | Roof(inside) insulation for exposed slabs/walls: \nSupply & fixing of 12 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3 | 1200 | Sq.m | |
801 | 23.153 | Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme)\na) INCOMER - 1 No. MCCB\nb) BUSBARS- 3 phase and neutral Aluminium bus bars with bus supports in suitable bus chamber.\nc) METERING- 0-250 Amp ammeter with CT's and selector switch, 0-500 volts voltmeter with selector switch and fuses.\nd) 1 set R.Y.B lmps with fuses.\ne) OUTGOING- TPN MCCB/ MPCB for pumps, cooling tower's, AHU's. & 1 No. earth bus(CU) throughout the panel with earthing bolts\nPump Panel with Energy meter in the Panel \n(Total HP- 105 HP) | 1 | Nos | |
802 | 23.154 | Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme)\na) INCOMMER - 1 No. MCCB\nb) BUSBARS- 3 phase and neutral Aluminium bus bars with bus supports in suitable bus chamber.\nc) METERING- 0-250 Amp ammeter with CT's and selector switch, 0-500 volts voltmeter with selector switch and fuses.\nd) 1 set R.Y.B lmps with fuses.\ne) OUTGOING- TPN MCCB/ MPCB for pumps, cooling tower's, AHU's. & 1 No. earth bus(CU) throughout the panel with earthing bolts\nAHU Panel -1 with above specifications & as per drawings - Basement, Ground floor\n(Total HP- 53 HP) | 1 | Nos | |
803 | 23.155 | Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme)\na) INCOMMER - 1 No. MCCB\nb) BUSBARS- 3 phase and neutral Aluminium bus bars with bus supports in suitable bus chamber.\nc) METERING- 0-250 Amp ammeter with CT's and selector switch, 0-500 volts voltmeter with selector switch and fuses.\nd) 1 set R.Y.B lmps with fuses.\ne) OUTGOING- TPN MCCB/ MPCB for pumps, cooling tower's, AHU's. & 1 No. earth bus(CU) throughout the panel with earthing bolts\nAHU Panel -2 with above specifications & as per drawings - Terrace floor, Left \n(Total HP- 49 HP) | 1 | Nos | |
804 | 23.156 | Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme)\na) INCOMMER - 1 No. MCCB\nb) BUSBARS- 3 phase and neutral Aluminium bus bars with bus supports in suitable bus chamber.\nc) METERING- 0-250 Amp ammeter with CT's and selector switch, 0-500 volts voltmeter with selector switch and fuses.\nd) 1 set R.Y.B lmps with fuses.\ne) OUTGOING- TPN MCCB/ MPCB for pumps, cooling tower's, AHU's. & 1 No. earth bus(CU) throughout the panel with earthing bolts\nAHU Panel -3 with above specifications & as per drawings - Terrace Floor, Left \n(Total HP- 34 HP) | 1 | Nos | |
805 | 23.157 | Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme)\na) INCOMMER - 1 No. MCCB\nb) BUSBARS- 3 phase and neutral Aluminium bus bars with bus supports in suitable bus chamber.\nc) METERING- 0-250 Amp ammeter with CT's and selector switch, 0-500 volts voltmeter with selector switch and fuses.\nd) 1 set R.Y.B lmps with fuses.\ne) OUTGOING- TPN MCCB/ MPCB for pumps, cooling tower's, AHU's. & 1 No. earth bus(CU) throughout the panel with earthing bolts\nAHU Panel -4 with above specifications & as per drawings - Terrace Floor, Right\n(Total HP- 57 HP) | 1 | Nos | |
806 | 23.158 | Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme)\na) INCOMMER - 1 No. MCCB\nb) BUSBARS- 3 phase and neutral Aluminium bus bars with bus supports in suitable bus chamber.\nc) METERING- 0-250 Amp ammeter with CT's and selector switch, 0-500 volts voltmeter with selector switch and fuses.\nd) 1 set R.Y.B lmps with fuses.\ne) OUTGOING- TPN MCCB/ MPCB for pumps, cooling tower's, AHU's. & 1 No. earth bus(CU) throughout the panel with earthing bolts\nAHU Panel -5 with above specifications & as per drawings - Terrace Floor, Right\n(Total HP- 64 HP) | 1 | Nos | |
807 | 23.159 | Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme)\na) INCOMER - 1 No. MCCB\nb) BUSBARS- 3 phase and neutral Aluminium bus bars with bus supports in suitable bus chamber.\nc) METERING- 0-250 Amp ammeter with CT's and selector switch, 0-500 volts voltmeter with selector switch and fuses.\nd) 1 set R.Y.B lmps with fuses.\ne) OUTGOING- TPN MCCB/ MPCB for pumps, cooling tower's, AHU's. & 1 No. earth bus(CU) throughout the panel with earthing bolts\nAHU Panel -6 with above specifications & as per drawings - Terrace Floor, Top\n(Total HP- 13 HP) | 1 | Nos | |
808 | 23.16 | SITC of Control box & DIGITAL DISPLAY PANEL inside the Operation theater with indication lamp, ON/OFF of AHU control, thermostat control of OT, cooling & heating mode, humidity control etc. Digital display of RH/TEMPERATURE, pressure (including pressure sensor & necessary control), wiring from AHU to unit etc. | 11 | Nos | |
809 | 23.161 | SITC of Central core Computer - PC (Intel i7 Processor ) , 8 GB RAM, 2 GB Graphics card, DVD Writer, 22" LED monitor, 1 TB HDD, Microsoft mouse, Keyboards, 2 serial, 1 parallel port/KB, Windows 8 operating system , antivirus software | 1 | Set | |
810 | 23.162 | SITC of A4 Colour Laser printer | 1 | Set | |
811 | 23.163 | Supply, Installation, Testing and Commissioning of Building Management System Graphic User Interface software with 3 user client license, user groups, user profiles and scopes, alarm handling, scheduling, trending, reporting engine, database system, system activity log, historical data management, real time zoom enabled vector graphics, system backup and restore, HTML based documentation and help, SMS/EMail facility complete in all respects as per tender specification. Graphical Software complete to cater to hardware points as specified in the Data Point Summary as well as Third Party Software Integrated Systems. | 1 | Lot | |
812 | 23.164 | SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer). Chiller System - 3 Chiller (50 points/chiller) | 1 | Lot | |
813 | 23.165 | SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer). Secondary Pumps System (10 Points/Pump) | 1 | Lot | |
814 | 23.166 | SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer). Variable Frequency Drives for AHU's (10 Points per VFD | 1 | Lot | |
815 | 23.167 | SITC of Networkable DDC Controllers as per Data Point Summary (1- 5 ) with enclosure with all necessary wiring and accessories | 1 | Lot | |
816 | 23.168 | SITC of Immersion Type Temperature Sensor | 4 | Nos. | |
817 | 23.169 | SITC of Outside Air Temperature & RH Sensor | 1 | No. | |
818 | 23.17 | SITC of Level Switch for expansion tank ( 2 point) (depth of tank - 1 mtr.) | 1 | No. | |
819 | 23.171 | SITC of Differential Pressure Switch | 8 | Nos. | |
820 | 23.172 | SITC of Level Switch for cooling tower | 3 | Nos. | |
821 | 23.173 | SITC of Diffrential Pressure sensor | 1 | Nos. | |
822 | 23.174 | Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC for AHU's | 2 | Nos | |
823 | 23.175 | Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC for AHU's | 2 | Nos | |
824 | 23.176 | SITC of Differential Pressure Switch across filter for AHU's | 6 | Nos. | |
825 | 23.177 | SITC of Return air Temperature Sensor for AHU's | 6 | Nos. | |
826 | 23.178 | Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC for Air Handling Units with Fine filter | 4 | Nos. | |
827 | 23.179 | Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC for Air Handling Units with Fine filter | 1 | Nos. | |
828 | 23.18 | SITC of Differential Pressure Switch across filter - pre filter and fine filter for Air Handling Units with Fine filter | 18 | Nos. | |
829 | 23.181 | SITC of Return air Temperature Sensor for Air Handling Units with Fine filter | 9 | Nos. | |
830 | 23.182 | Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC for Air Handling Units with Heater | 1 | Nos. | |
831 | 23.183 | SITC of Differential Pressure Switch across filter for Air Handling Units with Heater | 2 | Nos. | |
832 | 23.184 | SITC of Return air Temperature Sensor for Air Handling Units with Heater | 2 | Nos. | |
833 | 23.185 | SITC of RH Sensor Room type for Air Handling Units with Heater | 2 | Nos. | |
834 | 23.186 | Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC or 2 AHU / DDC for Air Handling Units with Fine filter, heater | 2 | Nos. | |
835 | 23.187 | SITC of Differential Pressure Switch across filter - pre filter and fine filter for Air Handling Units with Fine filter, heater | 4 | Nos. | |
836 | 23.188 | SITC of Return air Temperature Sensor for Air Handling Units with Fine filter, heater | 2 | Nos. | |
837 | 23.189 | SITC of RH Sensor Room type for Air Handling Units with Fine filter, heater | 2 | Nos. | |
838 | 23.19 | Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC - for OT AHU's | 11 | Nos. | |
839 | 23.191 | SITC of Differential Pressure Switch across filter -Pre filter,fine filter and Hepa filter - for OT AHU's | 33 | Nos. | |
840 | 23.192 | SITC of Return air Temperature Sensor for OT AHU's | 11 | Nos. | |
841 | 23.193 | SITC of RH Sensor Room type for OT AHU's | 11 | Nos. | |
842 | 23.194 | SITC of Air Diffrential Pressure Sensor for OT AHU's | 11 | Nos. | |
843 | 23.195 | Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories , consider 1 AHU / DDC for AHU WITH HEAT RECOVERY WHEEL | 1 | Nos. | |
844 | 23.196 | SITC of Differential Pressure Switch across filter for AHU WITH HEAT RECOVERY WHEEL | 1 | Nos. | |
845 | 23.197 | SITC of Return air Temperature Sensor for AHU WITH HEAT RECOVERY WHEEL | 1 | Nos. | |
846 | 23.198 | SITC of RH Sensor Room type for AHU WITH HEAT RECOVERY WHEEL | 1 | Nos. | |
847 | 23.199 | SITC of Signal Cabling - 2 Core 1.0 sq.mm. shielded FRLS armoured cable | 2260 | Meter | |
848 | 23.2 | SITC of Signal Cabling - 4 Core 1.0 sq.mm. shielded FRLS armoured cable | 775 | Meter | |
849 | 23.201 | SITC of Signal Cabling - 8 Core 1.0 sq.mm. shielded FRLS armoured cable | 750 | Meter | |
850 | 23.202 | SITC of Communication Cabling - 2 Core 1.5 sq.mm. shielded FRLS armoured cable or CAT5E armoured cable | 2400 | Meter | |
851 | 23.203 | SITC of Power Cable - 3 C X 2.5 SQMM -ATC Armoured Cable | 50 | Meter | |
852 | 24 | Public Health Engineering (PHE) System & Sewage Treatment Plant | |||
853 | 24.001 | Providing and fixing White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF Dual Cistern, overall size 765 x 370 x 650mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion/ rawl sleeves, gasket etc. complete, and fixing to wall, as per manufacturer's instruction and to the approval of Engineer-in-charge. Model Jaquar- FLS WHT- 5351, FLS -WHT-5201 or equivalent | 128 | each | |
854 | 24.002 | Providing, fixing, testing, and commissioning at site Disabled Toilet, Complete Set, including White Floor Mounted Water Closet, Suitable standard flushing cistern with internal fittings, Lid, Antimicrobial Soft close Seat Cover etc, Spatula Lever Basin Pillar tap and with 1 Set of Hinged Arm, 760mm. long, 4 Set of Grab Rail, each of 600mm. long, and with all necessary accessories and fixed with Brackets Expansion/ Rawl Sleeves, Stainless Steel/ Brass Bolts/Screws, Nuts, Washers etc, including cutting and making good the walls and floors wherever required including, all as per manufacturer's instruction and to the approval of Engineer-in-charge. Model - HINDWARE MATRIX set or Equivalent. | 6 | Set | |
855 | 24.003 | Supplying, installing, testing & commissioning at site in position white / colour vitreous china wash basin (480x365x205mm) with C.I./MS brackets painted white, C.P brass waste coupling of standard pattern, 32mm dia C.P, basin Pillarcock with aerator, including cutting & making good the walls wherever required complete.\nWash basin below counter type with aerator PillarCock. Model - JAQUAR CNS-WHT-701, FLR-5011N-1250, ALD 709, Or Equivalent. | 80 | each | |
856 | 24.004 | Supplying, installing, testing & commissioning at site in position white / colour vitreous china wash basin (550x400x195mm) with C.I./MS brackets painted white, C.P brass waste coupling of standard pattern, 32mm dia C.P, basin Pillarcock with aerator, including cutting & making good the walls wherever required complete.\nFlat back Pedestal wash basin PillarCock with aerator Model - JAQUAR CNS-WHT-801, FLR-5011N-1250, ALD 709 | 88 | each | |
857 | 24.005 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap | 8 | each | |
858 | 24.006 | Providing and fixing White vitreous china Laboratory Sink with C.I brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required; all as per manufacturer's instruction and the direction of Engineer-in-charge. Size: 600 x450 x 20mm. Deep | 64 | each | |
859 | 24.007 | Providing, Fixing & testing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm or 340x410x265 mm sizes with waste coupling respectively \nModel - Kerovit RASSO(ISI) - KS507 or Equivalent. | 18 | each | |
860 | 24.008 | Supplying, installing, testing & commissioning at site in position Self Closing Urinal Angle Valve with attachment and Flange of approved quality\nModel - Kerovit KA860004 or Equivalent. | 18 | each | |
861 | 24.009 | Providing and fixing CP 15 mm Urinal spreader size 95x69x100 mm with Steel screws and washers complete, including cutting and making good the walls wherever required.\nModel - Kerovit KA970001 or Equivalent. | 18 | each | |
862 | 24.01 | Supplying, installing, testing & commissioning at site in position vitreous china urinal partition (Size 330x105x683) with expandable anchor fasteners with C.P brass bolts and washers complete, including cutting and making good the walls wherever required.\nModel - Kerovit Division Plate - KS506 or Equivalent. | 10 | each | |
863 | 24.011 | Hot & cold CP aerator wall mixer unit - Providing, Fixing, testing and commissioning Of Hot & cold CP wall mixer unit with long bend pipe for overhead shower with all accessories. CP elbow and Overhead shower with revolving joint and shower arm with wall flanges etc complete. Model - JAQUAR Wall Mixer CON - 273 KNUPR,Shower arm SHA-477 190 mm long, Over head shower - OHS-CHR-1989 100mm dia or Equivalent | 24 | each | |
864 | 24.012 | Supplying and fixing SS Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. Model - JAQUAR ACN-1111-SM or Equivalent | 69 | each | |
865 | 24.013 | CP Towel Ring - Providing and Fixing CP Towel Ring trapezoidal shape 215mm long, 200mm wide with minimum distance of 37mm from wall face with concealed fittings arrangement of approved quality. Model - JAQUAR ACN-1121N or Equivalent | 48 | each | |
866 | 24.014 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.Model - JAQUAR - ALD-CHR-585 or Equivalent Hand Shower (Health Faucet)(ABS Body) With 1 metre long PVC Tube & Wall Hook or Equivalent. | 135 | each | |
867 | 24.015 | Supplying, installing, testing & commissioning at site in position soap tray by means of screws and rawl plug embedded in the walls complete including cutting and making good the walls wherever required. Model - Cera F5003106 or Equivalent | 69 | each | |
868 | 24.016 | Supplying, installing, testing & commissioning at site in position Heavy Duty Flexible Braided Connectors, 15mm. nominal bore, 450mm. Long with higher thermal stability for cold and Hot water, for Wash Basin & Kitchen Sink Mixer and Geyser points, of approved quality. | 350 | each | |
869 | 24.017 | Supplying, installing, testing & commissioning at site in position 15mm dia C.P Long Body brass aerator bib cocks with wall flange including cutting and making good the walls wherever required. Model - FLR-5047N- 1250 or Equivalent | 98 | each | |
870 | 24.018 | Providing and fixing Stainless Steel A ISI 304 (18/8) Kitchen Sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, waste coupling including painting of fittings and brackets, cutting and making good the walls wherever required\nKitchen sink with drain board\n510x1015 mm bowl depth 200 mm Model - DIAMOND REK 4020 OR Equivalent | 2 | each | |
871 | 24.019 | Providing and fixing Stainless Steel A ISI 304 (18/8) Kitchen Sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, waste coupling including painting of fittings and brackets, cutting and making good the walls wherever required\nKitchen sink without drain board\n610x510 mm bowl depth 200 mm Model - DIAMOND REK 2420 (BO) OR Equivalent | 2 | each | |
872 | 24.02 | Providing, fixing, testing, and commissioning at site Kitchen Sink Cock with aerator, Wall Mounted Type 15mm. nominal bore, overall dimensions: 208x237mm, including all necessary accessories, all as per manufacturer's instruction and to the approval of the Engineer-in-charge. Model - JAQUAR CON-357KN or Equivalent. | 10 | each | |
873 | 24.021 | Providing, fixing, testing, and commissioning at site Single Lever Surgical Purpose Elbow Action Sink Mixer (Wall Mounted)with aerator Extended Operating Lever, Connecting legs & wall flanges, 15mm. nominal bore, including all necessary accessories, all as per manufacturer's instruction and to the approval of the Engineer-in-charge.Model - JAQUAR FLR-5166 or Equivalent. | 68 | each | |
874 | 24.022 | Providing and fixing C.P brass stop cock ( concealed) with exposed path of standard design and of approved make conforming to IS: 8931 15 mm nominal bore Model - JAQUAR ALD-069FT\nJAQUAR CON-069FTK or Equivalent. | 38 | each | |
875 | 24.023 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 100 mm diametre Model - JAQUAR Shower arm SHA-477 190 mm long, Over head shower - OHS-CHR-1989 100mm dia or Equivalent | 38 | each | |
876 | 24.024 | Supplying, installing, testing & commissioning at site in position 15 mm dia angle valve with CP wall flange etc complete Model - JAQUAR FLR 5053 N or Equivalent | 510 | each | |
877 | 24.025 | Supplying, installing, testing & commissioning at site in position Toilet paper holder fixed to the wall by means of screws and rawl plug embedded in the walls complete including cutting and making good the walls wherever required. Model - JAQUAR ACN-1151N or Equivalent | 5 | each | |
878 | 24.026 | Supplying, installing, testing & commissioning at site in position Grab Bar up to 600mm complete. Model - Cera. Cat.No.B2210106 or Equivalent | 10 | each | |
879 | 24.027 | Mirror - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete.Saint Gobain or Equivalent | 55 | each | |
880 | 24.028 | Soap Dispenser - Providing and Fixing Soap dispenser of standard shape with bracket of approved quality and colour.Model JAQUAR ACN-1135N | 48 | each | |
881 | 24.029 | C. P. Robe Hook, 60mm. Dia. x 45mm. High.\nModel - JAQUAR ACN-1191N or Equivalent | 160 | each | |
882 | 24.03 | Providing,fixing testing and commissioning Energy Efficient Storage Type Electric Water Heater, 2kw each, as per specification\nCapacity 15 Ltrs | 18 | each | |
883 | 24.031 | Providing,fixing testing and commissioning Energy Efficient Storage Type Electric Water Heater, 2kw each, as per specification\nCapacity 25 Ltrs | 3 | each | |
884 | 24.032 | Providing,fixing testing and commissioning Energy Efficient Storage Type Electric Water Heater, 2kw each, as per specification\nCapacity 40 Ltrs | 5 | each | |
885 | 24.033 | Providing,fixing testing and commissioning Energy Efficient Storage Type Electric Water Heater, 2kw each, as per specification\nCapacity 60 Ltrs | 4 | each | |
886 | 24.034 | Providing,fixing testing and commissioning 1¼"x 32x300 CP Brass Tube Trap (P Trap) for wash basin. Adjusting pipe 120mm, drain elbow 220mm. Model - Cat No: Viega 704872 or equivalent. | 176 | each | |
887 | 24.035 | Providing,fixing testing and commissioning 1½"x 40x300 Plastic P Trap (P Trap) for Sink. Adjusting pipe 120mm, drain elbow 220mm. Model - Cat No: Viega 105952 or equivalent. | 86 | each | |
888 | 24.036 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Soil & Waste pipes -Internal).\n110mm OD | 495 | metre | |
889 | 24.037 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Soil & Waste pipes -Internal).\n75mm OD | 465 | metre | |
890 | 24.038 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe of 6Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, 'Y', couplings, adapters & clamping with Universal clamps/U bolt 1metre spacing, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Soil & Waste pipes -Internal).\n63 mm (IS 4985,6kgf/cm2) | 270 | metre | |
891 | 24.039 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe of 6Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, 'Y', couplings, adapters & clamping with Universal clamps/U bolt 1metre spacing, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Soil & Waste pipes -Internal).\n50 mm (IS 4985,6kgf/cm2) | 246 | metre | |
892 | 24.04 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe of 6Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, 'Y', couplings, adapters & clamping with Universal clamps 1metre spacing, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Soil & Waste pipes -Internal).\n40 mm (IS 4985,6kgf/cm2) | 140 | metre | |
893 | 24.041 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe of 10Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, 'Y', couplings, adapters & clamping with Universal clamps 1metre spacing, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n32 mm OD (10kg/cm2)- for sunken drain | 120 | metre | |
894 | 24.042 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type A (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Vent pipes -Internal).\n110mm OD | 12 | metre | |
895 | 24.043 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type A (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Vent pipes -Internal).\n90mm OD | 12 | metre | |
896 | 24.044 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type A (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Vent pipes -Internal).\n75mm OD | 286 | metre | |
897 | 24.045 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of 4kg/cm2 (IS:4985)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Vent pipes -Internal).\n63mm OD | 266 | metre | |
898 | 24.046 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of 4kg/cm2 (IS:4985)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site \n(For Vent pipes -Internal).\n50mm OD | 572 | metre | |
899 | 24.047 | Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).\nCore Cutting in RCC Structure shall measured separately.\nClamping details - For Vertical Shafts\nG.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated\nClamping details - For Suspended lines\nG.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.\n160mm OD | 15 | metre | |
900 | 24.048 | Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).\nCore Cutting in RCC Structure shall measured separately.\nClamping details - For Vertical Shafts\nG.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated\nClamping details - For Suspended lines\nG.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.\n110mm OD | 772 | metre | |
901 | 24.049 | Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).\nCore Cutting in RCC Structure shall measured separately.\nClamping details - For Vertical Shafts\nG.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated\nClamping details - For Suspended lines\nG.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.\n75mm OD | 672 | metre | |
902 | 24.05 | Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).\nClamping details - For Vertical Shafts\nG.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated\nClamping details - For Suspended lines\nG.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.\n160mm OD | 40 | metre | |
903 | 24.051 | Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).\nClamping details - For Vertical Shafts\nG.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated\nClamping details - For Suspended lines\nG.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.\n110mm OD | 820 | metre | |
904 | 24.052 | Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).\nClamping details - For Vertical Shafts\nG.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated\nClamping details - For Suspended lines\nG.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.\n75mm OD | 296 | metre | |
905 | 24.053 | Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of 4kg/cm2 (IS:4985)) including jointing PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).\nClamping details - For Vertical Shafts\nG.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated\nClamping details - For Suspended lines\nG.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.\n63 mm OD(4kg/cm2) | 760 | metre | |
906 | 24.054 | Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe of 6kg/cm2 (IS:4985)) including jointing with PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).\nClamping details - For Vertical Shafts\nG.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated\nClamping details - For Suspended lines\nG.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.\n50 mm OD(6kg/cm2) | 30 | metre | |
907 | 24.055 | Deep Seal uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position Deep Seal (7”) uPVC Fabricated Multi Floor Trap, with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, Anchor fasteners etc. complete in all respects - 50/75 mm dia inlet/outlet (In Ceiling) | 220 | each | |
908 | 24.056 | uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost o cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken) | 14 | each | |
909 | 24.057 | C.P. cast brass or stainless steel Square Flat cut lock anti cockroach grating cover - Providing and Fixing Heavy Duty Stainless Steel Square Flat cut lock anti Cockroach Trap Stainless Steel A ISI 304 with 153x153mm. Grating, for 110mm. Floor Traps. | 401 | each | |
910 | 24.058 | Heavyduty stainless steel cover for Concealed Floor Trap for Urinal - Providing and Fixing 153x153mm dia Heavyduty stainless steel cover for Concealed Floor Trap ISI 304 Cover, for Urinal. | 33 | each | |
911 | 24.059 | Heavyduty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable insert keys for opening, if required. | 25 | each | |
912 | 24.06 | Low noise level soil & waste system 110mm Dia - Providing, Fixing, testing Low noise level soil & waste system as per EN 12056, DIN 4109, as approved in proper line and level jointing With push fit rubber ring socket fittings complete with holder bats or dash fasteners fixed to walls or ceiling or run on floor or in trenches at require slopes and necessary special heavy Detachable Hot Dip Galvanized M.S. Brackets, Hangers, clamps and bricks / RCC pedestals as directed, including clamps, bracket, supports in MS making good walls etc. The rates for pipes shall be inclusive of all the specials, and fittings like elbow, rodding eye etc., The diametre of pipe shall be of the following nominal bore.(Pipes and fittings shall consist of polypropylene mineral reinforce with sound insulation density not less than 1.9gm/cm3). Astral Silencio shall have a B2 fire classification according to EN 4102 and shall be hot water resistant up to 95°C short term loading (90°C long term loading) with a chemical resistance of pH 2-12 and complete sound protection system according to DIN 4109. Galvanized clamps and brackets, legend boards shall be included in the price. | 480 | metre | |
913 | 24.061 | Low noise level soil & waste system 75mm Dia - Providing, Fixing, testing Low noise level soil & waste system as per EN 12056, DIN 4109, as approved in proper line and level jointing With push fit rubber ring socket fittings complete with holder bats or dash fasteners fixed to walls or ceiling or run on floor or in trenches at require slopes and necessary special heavy Detachable Hot Dip Galvanized M.S. Brackets, hangers, clamps and bricks / RCC pedestals as directed, including clamps, bracket, supports in MS making good walls etc. The rates for pipes shall be inclusive of all the specials and fittings like elbow, rodding eye etc. The diametre of pipe shall be of the following nominal bore.(Pipes and fittings shall consist of polypropylene mineral reinforce with sound insulation density not less than 1.9gm/cm3). Astral Silencio shall have a B2 fire classification according to EN 4102 and shall be hot water resistant up to 95°C short term loading (90°C long term loading) with a chemical resistance of pH 2-12 and complete sound protection system according to DIN 4109. Galvanized clamps and brackets, legend boards shall be included in the price. | 860 | metre | |
914 | 24.062 | Low noise level soil & waste system 50mm Dia - Providing, Fixing, testing Low noise level soil & waste system as per EN 12056, DIN 4109, as approved in proper line and level jointing With push fit rubber ring socket fittings complete with holder bats or dash fasteners fixed to walls or ceiling or run on floor or in trenches at require slopes and necessary special heavy Detachable Hot Dip Galvanized M.S. Brackets, hangers, clamps and bricks / RCC pedestals as directed, including clamps, bracket, supports in MS making good walls etc. The rates for pipes shall be inclusive of all the specials and fittings like elbow, rodding eye etc. The diametre of pipe shall be of the following nominal bore.(Pipes and fittings shall consist of polypropylene mineral reinforce with sound insulation density not less than 1.9gm/cm3). Astral Silencio shall have a B2 fire classification according to EN 4102 and shall be hot water resistant up to 95°C short term loading (90°C long term loading) with a chemical resistance of pH 2-12 and complete sound protection system according to DIN 4109. Galvanized clamps and brackets, legend boards shall be included in the price. | 340 | metre | |
915 | 24.063 | Low noise level soil & waste system 110mm Dia - Providing, Fixing, testing Low noise level soil & waste system as per EN 12056, DIN 4109, as approved in proper line and level jointing With push fit rubber ring socket fittings complete including clamping with Position, including cutting and making good the walls and floors as required at site. The rates for pipes shall be inclusive of all the specials, and fittings like elbow, rodding eye etc., The diametre of pipe shall be of the following nominal bore.(Pipes and fittings shall consist of polypropylene mineral reinforce with sound insulation density not less than 1.9gm/cm3). Astral Silencio shall have a B2 fire classification according to EN 4102 and shall be hot water resistant up to 95°C short term loading (90°C long term loading) with a chemical resistance of pH 2-12 and complete sound protection system according to DIN 4109.\nClamping details - For Vertical Shafts\nG.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated\nClamping details - For Suspended lines\nG.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. | 504 | metre | |
916 | 24.064 | Supplying, installing & testing at site in position Deep Seal Polypropylene floor trap (ht 7") - (sound level 13dB @4L/sec) supporting on GI slotted rails (1.6mmthick) full threaded rod, Anchor fasteners etc. with all necessary fittings of approved make. | 165 | each | |
917 | 24.065 | Supplying, installing & testing at site in position Polypropylene P Trap - (sound level 13dB @4L/sec)of size 110mm dia of approved make for Drainage, complete with all necessary fittings of approved make as per drawings to the satisfaction of the project manager. | 3 | each | |
918 | 24.066 | Supplying, installing, testing & commissioning at site in position 110mm dia deep seal PVC P Trap with boss tee and access cap including all necessary fittings and supports complete. | 25 | each | |
919 | 24.067 | Providing, Fixing, Testing & Commissioning at site in position of Hubless Centrifugally Cast Iron Pipes and fittings (Epoxy coated Inside & Outside as per (IS:15905, ISO 6594) Standard and jointing with Stainless Steel Shielded (SS-304) Coupling with a double Stainless Steel bolt and screw Housing in corporating a EPDM Rubber Gasket as per IS-15905/ ASTM 1277 Standard inclusive of all necessary specials like Bends, Tees, Offset, Junctions, Cowls, End plug, Inspection Pipes, Rodding eye, etc. laid under floor / fixed on walls and in shafts. The rate shall be including suitable angle supports, Hanger, nuts, bolts, anchor fastner, fixing Clamps / Channels with U Bolt, etc. complete. Hubless Cast Iron Pipes & Fitting should have been tested for Noise level which should not more than 25dB (A) at L/s.\n(For CSSD and Laundry Drainage).100 mm dia | 65 | metre | |
920 | 24.068 | Providing, Fixing, Testing & Commissioning at site in position of Hubless Centrifugally Cast Iron Pipes and fittings (Epoxy coated Inside & Outside as per (IS:15905, ISO 6594) Standard and jointing with Stainless Steel Shielded (SS-304) Coupling with a double Stainless Steel bolt and screw Housing in corporating a EPDM Rubber Gasket as per IS-15905/ ASTM 1277 Standard inclusive of all necessary specials like Bends, Tees, Offset, Junctions, Cowls, End plug, Inspection Pipes, Rodding eye, etc. laid under floor / fixed on walls and in shafts. The rate shall be including suitable angle supports, Hanger, nuts, bolts, anchor fastner, fixing Clamps / Channels with U Bolt, etc. complete. Hubless Cast Iron Pipes & Fitting should have been tested for Noise level which should not more than 25dB (A) at L/s.\n(For CSSD and Laundry Drainage).75 mm dia | 20 | metre | |
921 | 24.069 | Providing, Fixing, Testing & Commissioning at site in position of Hubless Centrifugally Cast Iron Pipes and fittings (Epoxy coated Inside & Outside as per (IS:15905, ISO 6594) Standard and jointing with Stainless Steel Shielded (SS-304) Coupling with a double Stainless Steel bolt and screw Housing in corporating a EPDM Rubber Gasket as per IS-15905/ ASTM 1277 Standard inclusive of all necessary specials like Bends, Tees, Offset, Junctions, Cowls, End plug, Inspection Pipes, Rodding eye, etc. laid under floor / fixed on walls and in shafts. The rate shall be including suitable angle supports, Hanger, nuts, bolts, anchor fastner, fixing Clamps / Channels with U Bolt, etc. complete. Hubless Cast Iron Pipes & Fitting should have been tested for Noise level which should not more than 25dB (A) at L/s.\n(For CSSD and Laundry Drainage).50 mm dia | 10 | metre | |
922 | 24.07 | Supplying & Fixing 110mm dia deep seal Cast Iron 'P' trap with access cap inside & outside as per IS:15905 Including all necessary fittings & supports complete (For CSSD and Laundry Drainage). | 5 | each | |
923 | 24.071 | Supplying, Installing & Testing at site in position Hubless centrifugally cast (spun) iron epoxy coated Multi inlet trap inside & outside as per IS:15905 supporting on G.I. slotted rails (1.6 mm thick), Full threaded rod , Anchor Fasteners etc at site. (For CSSD and Laundry Drainage). | 2 | each | |
924 | 24.072 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter\nand weighing not less than 440 grams. | 26 | EACH | |
925 | 24.073 | Providing, fixing, pressure testing and commission Concealed Cold Water Services Pipe Work, with High Pressure uPVC Pipes, Sch. 40 (ASTM D 1785) and Sch. 40 (ASTM D 2466) Fittings, such as Elbows, Tees, Reducers, 15mm. Female Brass Threaded Elbows, Tess & Sockets, as per requirement, Sockets, Flanges, Unions, Adaptors, End Plugs etc, Pipe Supports, Fasteners, Clamps, Expansion Joints, Bolts, Washers, Nuts, Masonary Supports etc, as per requirement and site conditions, including cutting, chasing, drilling etc, in Block Walls, RCC Slabs etc, wherever required and making good walls, floors, duct etc. The Solvent Cement shall be one step for pressure pipes and fittings from the same Manufacturer. All as per Technical Specifications and to the approval of Engineer- in -Charge.\nConcealed work, including cutting chases and making good the walls etc.\n15 mm nominal outer dia. Pipes. | 48 | metre | |
926 | 24.074 | Providing, fixing, pressure testing and commission Concealed Cold Water Services Pipe Work, with High Pressure uPVC Pipes, Sch. 40 (ASTM D 1785) and Sch. 40 (ASTM D 2466) Fittings, such as Elbows, Tees, Reducers, 15mm. Female Brass Threaded Elbows, Tess & Sockets, as per requirement, Sockets, Flanges, Unions, Adaptors, End Plugs etc, Pipe Supports, Fasteners, Clamps, Expansion Joints, Bolts, Washers, Nuts, Masonary Supports etc, as per requirement and site conditions, including cutting, chasing, drilling etc, in Block Walls, RCC Slabs etc, wherever required and making good walls, floors, duct etc. The Solvent Cement shall be one step for pressure pipes and fittings from the same Manufacturer. All as per Technical Specifications and to the approval of Engineer- in -Charge.\nConcealed work, including cutting chases and making good the walls etc.\n20 mm nominal outer dia. Pipes. | 1842 | metre | |
927 | 24.075 | Providing, fixing, pressure testing and commission Concealed Cold Water Services Pipe Work, with High Pressure uPVC Pipes, Sch. 40 (ASTM D 1785) and Sch. 40 (ASTM D 2466) Fittings, such as Elbows, Tees, Reducers, 15mm. Female Brass Threaded Elbows, Tess & Sockets, as per requirement, Sockets, Flanges, Unions, Adaptors, End Plugs etc, Pipe Supports, Fasteners, Clamps, Expansion Joints, Bolts, Washers, Nuts, Masonary Supports etc, as per requirement and site conditions, including cutting, chasing, drilling etc, in Block Walls, RCC Slabs etc, wherever required and making good walls, floors, duct etc. The Solvent Cement shall be one step for pressure pipes and fittings from the same Manufacturer. All as per Technical Specifications and to the approval of Engineer- in -Charge.\nConcealed work, including cutting chases and making good the walls etc.\n25 mm nominal outer dia. Pipes. | 30 | metre | |
928 | 24.076 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.\nConcealed work, including cutting chases and making good the walls etc.\n15 mm nominal outer dia. Pipes. | 60 | metre | |
929 | 24.077 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.\nConcealed work, including cutting chases and making good the walls etc.\n20 mm nominal outer dia. Pipes. | 504 | metre | |
930 | 24.078 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.\nConcealed work, including cutting chases and making good the walls etc.\n25 mm nominal outer dia. Pipes. | 30 | metre | |
931 | 24.079 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n15 mm nominal outer dia. Pipes. | 546 | metre | |
932 | 24.08 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n20 mm nominal outer dia. Pipes. | 294 | metre | |
933 | 24.081 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n25 mm nominal outer dia. Pipes. | 96 | metre | |
934 | 24.082 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n32 mm nominal outer dia. Pipes. | 8 | metre | |
935 | 24.083 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n15 mm nominal outer dia. Pipes. | 40 | metre | |
936 | 24.084 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n20 mm nominal outer dia. Pipes. | 1878 | metre | |
937 | 24.085 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n25 mm nominal outer dia. Pipes. | 630 | metre | |
938 | 24.086 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n32 mm nominal outer dia. Pipes. | 324 | metre | |
939 | 24.087 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n40 mm nominal outer dia. Pipes. | 180 | metre | |
940 | 24.088 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n50 mm nominal outer dia. Pipes. | 95 | metre | |
941 | 24.089 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n65 mm nominal outer dia. Pipes. | 80 | metre | |
942 | 24.09 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n80 mm nominal outer dia. Pipes. | 20 | metre | |
943 | 24.091 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n100 mm nominal outer dia. Pipes. | 36 | metre | |
944 | 24.092 | Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n65 mm nominal outer dia. Pipes. | 108 | metre | |
945 | 24.093 | Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n80 mm nominal outer dia. Pipes. | 36 | metre | |
946 | 24.094 | Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n100 mm nominal outer dia. Pipes. | 12 | metre | |
947 | 24.095 | Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.\nInternal work - Exposed on wall - Ceiling and Shaft\n150 mm nominal outer dia. Pipes. | 6 | metre | |
948 | 24.096 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(9mm thick) for the hot water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n15 mm | 10 | metre | |
949 | 24.097 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(9mm thick) for the hot water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n20 mm | 126 | metre | |
950 | 24.098 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(9mm thick) for the hot water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n25mm | 24 | metre | |
951 | 24.099 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(19mm thick) for the Terrace cold water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n20 mm | 42 | metre | |
952 | 24.1 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(19mm thick) for the Terrace cold water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n25 mm | 42 | metre | |
953 | 24.101 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(19mm thick) for the Terrace cold water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n32 mm | 32 | metre | |
954 | 24.102 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(19mm thick) for the Terrace cold water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n40 mm | 58 | metre | |
955 | 24.103 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(19mm thick) for the Terrace cold water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n50 mm | 312 | metre | |
956 | 24.104 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(19mm thick) for the Terrace cold water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n65 mm | 60 | metre | |
957 | 24.105 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(19mm thick) for the Terrace cold water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n80 mm | 402 | metre | |
958 | 24.106 | Supplying, Installing & Testing at site in position micro cellular closed cell Nitrile rubber elastomeric insulation (UL-94 Approved) tubes/ sheets(19mm thick) for the Terrace cold water supply pipes with protective glass fabric & co-extruded polymeric covering for UV & mechanical protection. \n100 mm | 86 | metre | |
959 | 24.107 | Brass ball valve 15mm dia - Providing, Fixing at site in position full way lever operated forged Brass ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 25) of approved make with necessary MTA fittings in position as per drawing - ½” (15mm) dia | 10 | each | |
960 | 24.108 | Brass ball valve 20mm dia - Providing, Fixing at site in position full way lever operated forged Brass ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 25) of approved make with necessary MTA fittings in position as per drawing - ¾” (20mm) dia | 383 | each | |
961 | 24.109 | Brass ball valve 25mm dia - Providing, Fixing at site in position full way lever operated forged Brass ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 25) of approved make with necessary MTA fittings in position as per drawing - 1” (25mm) dia | 42 | each | |
962 | 24.11 | Brass ball valve 32mm dia - Providing, Fixing at site in position full way lever operated forged Brass ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 25) of approved make with necessary MTA fittings in position as per drawing - 1¼”(32mm) dia | 31 | each | |
963 | 24.111 | Brass ball valve 40mm dia - Providing, Fixing at site in position full way lever operated forged Brass ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 25) of approved make with necessary MTA fittings in position as per drawing - 1 ½”(40mm) dia | 11 | each | |
964 | 24.112 | Brass ball valve 50mm dia - Providing, Fixing at site in position full way lever operated forged Brass ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 25) of approved make with necessary MTA fittings in position as per drawing - 2” (50mm) dia | 13 | each | |
965 | 24.113 | Non Return Valves 1¼”(32mm) dia - Supplying, Installing & Testing at site in position spring loaded Brass Non Return Valve (PN-16) screw type with necessary fittings complete in all respect. | 1 | each | |
966 | 24.114 | Non Return Valves 1 ½” (40mm) dia - Supplying, Installing & Testing at site in position spring loaded Brass Non Return Valve (PN-16) screw type with necessary fittings complete in all respect. | 2 | each | |
967 | 24.115 | Non Return Valves 2” (50mm) dia - Supplying, Installing & Testing at site in position spring loaded Brass Non Return Valve (PN-16) screw type with necessary fittings complete in all respect. | 2 | each | |
968 | 24.116 | Non Return Valves 2 ½” (65mm) dia - Supplying, Installing & Testing at site in position spring loaded Brass Non Return Valve (PN-16) screw type with necessary fittings complete in all respect. | 8 | each | |
969 | 24.117 | Brass Automatic Air Release Valves - Providing, Fixing, testing and commissioning at site in positions Brass Automatic Air Release Valves, of approved quality and make on the top of the vertical water supply pipes as per specification and drawing - 3/4"(20mm) dia | 62 | each | |
970 | 24.118 | Brass Y Strainer 1 ½” (40mm) dia - Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects - | 1 | each | |
971 | 24.119 | Brass Y Strainer 3” (80mm) dia - Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects - | 2 | each | |
972 | 24.12 | Brass Y Strainer 4” (100mm) dia - Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects - | 1 | each | |
973 | 24.121 | Supplying, Installing & Testing at site in position Brass Float valve (PN 16) of approved make with PP float & nipple with brass threaded insert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 40mm dia (1 ½”) | 2 | Each | |
974 | 24.122 | SS ball valve 15mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - ½” (15mm) dia | 5 | each | |
975 | 24.123 | SS ball valve 20mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - ¾” (20mm) dia | 46 | each | |
976 | 24.124 | SS ball valve 25mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - 1” (25mm) dia | 8 | each | |
977 | 24.125 | SS ball valve 32mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - 1 1/4” (32mm) dia | 5 | each | |
978 | 24.126 | SS ball valve 40mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - 1 1/2” (40mm) dia | 2 | each | |
979 | 24.127 | SS ball valve 50mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - 2” (50mm) dia | 3 | each | |
980 | 24.128 | Providing and fixing C.I. Sluice Valve, PN-16, with IS: 14846 Mark, with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. 100mm. PN-16 | 1 | each | |
981 | 24.129 | CI Butterfly valve 250mm dia (PN 10) - Providing, Fixing at site in position CI Butterfly valve (PN 10) wafer type of approved make with necessary PVC flanges, gaskets, nuts and bolts etc complete within position as per drawing - 10”(250mm) dia | 2 | each | |
982 | 24.13 | Providing and Fixing Ball Type Foot Valve. PN 10, with Cast Iron Body Nitrile Reinforced Ball, Screwed End, required in the Suction Lines of for Water Transfer and Distribution Pumps.65mm. | 1 | each | |
983 | 24.131 | Providing and Fixing Ball Type Foot Valve. PN 10, with Cast Iron Body Nitrile Reinforced Ball, Screwed End, required in the Suction Lines of for Water Transfer and Distribution Pumps.50mm. | 3 | each | |
984 | 24.132 | Supplying, installing,Testing & commissioning at site in position Multi Jet Water meter with unions of removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totaliser,retrofitable for pulse output and conforming to ISO-4064 Class B complete. Water meter 40mm | 3 | each | |
985 | 24.133 | CI Butterfly valve 65mm dia (PN 10) - Providing, Fixing at site in position CI Butterfly valve (PN 10) wafer type of approved make with necessary PVC flanges, gaskets, nuts and bolts etc complete within position as per drawing - 2 ½”(65mm) dia | 23 | each | |
986 | 24.134 | CI Butterfly valve 80mm dia (PN 10) - Providing, Fixing at site in position CI Butterfly valve (PN 10) wafer type of approved make with necessary PVC flanges, gaskets, nuts and bolts etc complete within position as per drawing - 3”(80mm) dia | 11 | each | |
987 | 24.135 | CI Butterfly valve 100mm dia (PN 10) - Providing, Fixing at site in position CI Butterfly valve (PN 10) wafer type of approved make with necessary PVC flanges, gaskets, nuts and bolts etc complete within position as per drawing - 4”(100mm) dia | 6 | each | |
988 | 24.136 | CI Butterfly valve 150mm dia (PN 10) - Providing, Fixing at site in position CI Butterfly valve (PN 10) wafer type of approved make with necessary PVC flanges, gaskets, nuts and bolts etc complete within position as per drawing - 6”(150mm) dia | 2 | each | |
989 | 24.137 | SS Butterfly valve 65mm dia (PN 16) - Providing, Fixing at site in position SS Butterfly valve (PN 16) wafer type of approved make with necessary PVC flanges, gaskets, nuts and bolts etc complete within position as per drawing - 2 ½”(65mm) dia | 2 | each | |
990 | 24.138 | Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete\n200mm OD | 36 | metre | |
991 | 24.139 | Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete\n160mm OD | 1356 | metre | |
992 | 24.14 | Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete\n110mm OD | 366 | metre | |
993 | 24.141 | Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete\n75mm OD | 180 | metre | |
994 | 24.142 | Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for rain water pipes) complete\n250mm OD | 132 | metre | |
995 | 24.143 | Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for rain water pipes) complete\n200mm OD | 72 | metre | |
996 | 24.144 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\nExternal work (Including excavation)\n20 mm nominal outer dia Pipes | 75 | metre | |
997 | 24.145 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\nExternal work (Including excavation)\n25 mm nominal outer dia Pipes | 50 | metre | |
998 | 24.146 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\nExternal work (Including excavation)\n32 mm nominal outer dia Pipes | 100 | metre | |
999 | 24.147 | Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\nExternal work (Including excavation)\n40 mm nominal outer dia Pipes | 50 | metre | |
1000 | 24.148 | Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\nExternal work (Including excavation)\n50 mm nominal outer dia Pipes | 372 | metre | |
1001 | 24.149 | Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\nExternal work (Including excavation)\n65 mm nominal outer dia Pipes | 390 | metre | |
1002 | 24.15 | Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\nExternal work (Including excavation)\n80 mm nominal outer dia Pipes | 204 | metre | |
1003 | 24.151 | Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\nExternal work (Including excavation)\n100 mm nominal outer dia Pipes | 6 | metre | |
1004 | 24.152 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : \nInside size 60x60 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :\nWith Sewer bricks conforming to IS : 4885 | 5 | each | |
1005 | 24.153 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand)finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :\nWith Sewer bricks conforming to IS : 4885 | 39 | each | |
1006 | 24.154 | Extra for depth for manholes : \nSize 90x80 cm\nWith Sewer bricks conforming to IS : 4885 | 17 | metre | |
1007 | 24.155 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:\nInside size 120x 90 cm and 90 cm deep including C.I. cover with frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg ( weight of cover 108 kg and weight of frame 100 kg)\nWith Sewer bricks conforming to IS: 4885 | 34 | each | |
1008 | 24.156 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:\nInside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):\nWith Sewer bricks conforming to IS : 4885 | 2 | each | |
1009 | 24.157 | Supply,installation, testing and commissioning of stainless steel coarse Screen (opening 10mm) suitable for screen chamber of size 1.00mx1.50m including all material charges,labour transportation,loading unloading etc. Complete as per the direction of Engineer in charge. | 2 | No | |
1010 | 24.158 | Extra for depth for manholes\nSize 120x90 cm\nWith Sewer bricks conforming to IS : 4885 | 13 | metre | |
1011 | 24.159 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottam and 0.56 m dia at to[ in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ), and making necessary channel in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:\nWith Sewer bricks conforming to IS:4885 | 10 | each | |
1012 | 24.16 | Extra depth circular type manhole 0.91 m internal dia ( at bottom) beyound 0.91 m to 1.67 m\nWith Sewer bricks conforming IS: 4885 | 7.6 | metre | |
1013 | 24.161 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:\n1.68 m deep with SFRC cover and frame (heavy duty Hd- 20 grade designation)\n560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. ( Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately)\nWith sewer bricks conforming IS:4885 | 15 | each | |
1014 | 24.162 | Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m:\nWith sewer bricks conforming IS:4885 | 9 | metre | |
1015 | 24.163 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement:4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, all complete as per standard design:\n2.30 m deep with SFRC cover and frame (heavy duty HD - 20 grade designation)\n560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately):\nWith sewer bricks conforming IS:4885 | 3 | each | |
1016 | 24.164 | Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m:\nWith Sewer bricks conforming IS: 4885 | 2 | metre | |
1017 | 24.165 | Supplying, Installing & Testing at site in position best quality PVC gully trap of size 160 X110mm outlet embedded in plain cement concrete 1:4:8 (20mm metal), all the above encased in a chamber of 300 X 300mm built with 115mm thick brick masonry using first class country bricks in CM 1:3 over a bed of CC 1:4:8 using 40mm size metal 100mm thick ,plastering with CM1:3,13mm thick inside, outside, exposed top surfaces and internal and top exposed surface finished smooth with a floating coat of neat cement, providing and fixing Ductile Iron(Hinged type) frame and cover of size 300 X 300mm weighing not less than 8 kgs load tested as per IS:1726 fixing the frame in PCC 1:2:4 using 20mm stone metal including painting the frame and cover with 2 coats of anticorrosive black bitumastic painting etc. complete all as specified and directed. | 42 | EACH | |
1018 | 24.166 | Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 \n(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:\nWith common burnt clay F.P.S (non modular) bricks of class designation 7.5 | 17 | EACH | |
1019 | 24.167 | Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:\nWith common burnt clay F.P.S (non modular) bricks of class designation 7.5 | 5 | EACH | |
1020 | 24.168 | Constructing masonry chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 \n(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:\nWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 1 | EACH | |
1021 | 24.169 | Constructing masonry chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grades stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:\nWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 1 | EACH | |
1022 | 24.17 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)\nComplete as per design | 100 | no | |
1023 | 24.171 | Excavating trenches of required width for pipes, including excavation for sockets, depth up to 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :\nIn all kinds of Soil\nPipes and cables not exceeding 80 mm dia. | 180 | metre | |
1024 | 24.172 | Excavating trenches of required width for pipes, including excavation for sockets, depth up to 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :\nIn all kinds of Soil\nPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia | 1962 | Metre | |
1025 | 24.173 | Extra for excavating trenches for pipes above 80mm. But not exceeding 300mm.. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). | 120 | Metre | |
1026 | 24.174 | Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : \nSub analysis item for sand filling component | 90 | cum | |
1027 | 24.175 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).Around under ground UPVC pipes. | 150 | cum | |
1028 | 24.176 | Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 160mm dia. | 4 | each | |
1029 | 24.177 | Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 110mm dia. | 636 | each | |
1030 | 24.178 | Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 75mm dia. | 30 | each | |
1031 | 24.179 | Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 50mm dia. | 250 | each | |
1032 | 24.18 | Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 40mm dia. | 100 | each | |
1033 | 24.181 | Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 32mm dia. | 151 | each | |
1034 | 24.182 | 600 X 600 mm (24" X 24") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Light Duty (5 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124.\nFor OH Water tank | 4 | each | |
1035 | 24.183 | 600 X 900 mm (24" X 36") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Heavy Duty (20 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124.\nFor UG Sump | 7 | each | |
1036 | 24.184 | 600 X 600 mm (24" X 24") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Heavy Duty (20 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124.\nFor UG Sump | 6 | each | |
1037 | 24.185 | Supplying, Installing & Testing at site in position Fabricated 150mm (6")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 150mm(6") uPVC Astm Sch 80 Puddle flange | 4 | each | |
1038 | 24.186 | Supplying, Installing & Testing at site in position Fabricated 100mm (4")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 100mm(4") uPVC Astm Sch 80 Puddle flange | 10 | each | |
1039 | 24.187 | Supplying, Installing & Testing at site in position Fabricated 80mm (3")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 80mm(3") uPVC Astm Sch 80 Puddle flange | 6 | each | |
1040 | 24.188 | Supplying, Installing & Testing at site in position Fabricated 65mm (2½") uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 65mm (2½") uPVC Astm Sch 80 Puddle flange | 10 | each | |
1041 | 24.189 | Supplying, Installing & Testing at site in position Fabricated 50mm (2")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 50mm(2") uPVC Astm Sch 80 Puddle flange | 3 | each | |
1042 | 24.19 | Supplying, Installing & Testing at site in position Fabricated 40mm (1½")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -40mm (1½")uPVC Astm Sch 80 Puddle flange | 2 | each | |
1043 | 24.191 | Supplying, Installing & Testing at site in position Fabricated 32mm (1¼")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 32mm 1¼"uPVC Astm Sch 80 Puddle flange | 1 | each | |
1044 | 24.192 | Vertical multi stage centrifugal pumps (surface pump) for Domestic Water Supply - Providing, Fixing, Testing and Commissioning 2 nos, Vertical multi stage centrifugal pumps (surface pump) set, having SS/Bronze Impeller, Shafts and CI casing, Mechanical Seal Each pumps should be capable to deliver 12 lps @ 60mtr head, Head range 40 to 75mtrs (14.5 lps to 7.08 lps), with 9.3kW/12.5 HP'' F'' class motor, with motor efficiency more than 85% with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1W + 1S ) having features of automatic pump change over in every Start/Stop, Dry run , Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function , Digital display , Float Switches, Auto/Manuel Operation . The total system shall be assembled and tested at factory as per the duty conditions. (For Domestic Water from sump to OHT)\nBrand Grundfos OR Equivalent | 1 | Set | |
1045 | 24.193 | Providing, Fixing, Testing and Commission Pressure Booster Flushing Water Distribution System with Factory Assembled Packaged Pump Set, Suitable for Negative Suction for Pumping Raw Water from a Depth of 4 Mtr, complete with 3 Vertical Multistage Inline Pumps, with S. S Impeller and S. S Shafts, One Working, One Assist and 1 Stand by Pumps, each of Capacity: 14.5M3 / Hr @ 50 Mtr. Head, each, with 3.7 / 4.0kW, 3Ph, IE3 Rated Electric Motors, complete with VFD Drive, Automatic Microprocessor Based Control Panel, Pressure Transducer Sensors, Pressure Gauges, 200Ltr. Diaphragm Pressure Vessel, Individual Suction Lines, Common Delivery Manifolds, Isolating Valves, Non Return Valves, Fittings, Accessories etc, all a on common frame. . etc, all a on common frame. The Quoted Price for the Pump Set shall be inclusive of connected Electrical Work, all as per Technical Specifications.\nEach Pump Shall be capable of working with Negative Suction for Pumping Raw Water from a Depth of 4 Mtr, The Manufacturer can decide the Pumps accordingly.Brand Grundfos OR Equivalent | 1 | Set | |
1046 | 24.194 | Sewage Solid handling pumps - Supply, installing, testing and commissioning of Submersible non clog Sewage Solid handling pumps. Control Panel for Controlling 2 Pumps, having SS: Shaft and CI Casing, impeller, Each pumps should be capable to deliver 5 lps @ 8mtr head for each pump, solid handling 50mm with 1.11kW/1.5HP with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1W + 1S ) having features of Cyclic Timer for Cascading Operation and Float Switch/Probe Suitable for Automatic Operation. The Panel should have the following Protection for Single Phase Prevention, Over Load Protection, Over /Under Voltage Protection, Dry Running Protection, Transient Surge Protection, with Auto/Manual Operation & Auto coupling . The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication( Modbus). (For Medical Waste Tranfer Pump)\nBrand Grundfos OR Equivalent | 2 | Set | |
1047 | 24.195 | Sewage Solid handling pumps - Supply, installing, testing and commissioning of Submersible non clog Sewage Solid handling pumps. Control Panel for Controlling 2 Pumps, having SS: Shaft and CI Casing, impeller, Each pumps should be capable to deliver 4 lps @ 8mtr head for each pump, solid handling 50mm with 1.11kW/1.5HP with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1W + 1S ) having features of Cyclic Timer for Cascading Operation and Float Switch/Probe Suitable for Automatic Operation. The Panel should have the following Protection for Single Phase Prevention, Over Load Protection, Over /Under Voltage Protection, Dry Running Protection, Transient Surge Protection, with Auto/Manual Operation & Auto coupling . The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication( Modbus). (For Medical Waste Tranfer Pump)\nBrand Grundfos OR Equivalent | 1 | Set | |
1048 | 24.196 | FILTER FEED PUMP SET.\nProviding, Fixing, Testing and Commission Filter Feed Pump Set, Submersible Type for Pumping Raw Water to Water Treatment Plant, 2 Pump System with One Working + 1 One Cyclically Stand by Pumps, each Pump of Capacity: 20M3 / Hr. @ 45Mtr. Head, each, with 5.5kW, 3Ph, IE3 Rated Electric Motors, complete with Microprocessor Based Control Panel, for Auto and Cyclic Operation, with all Protection (Digital display, Low &high voltage protection, dry run, phase reversal, pump over load, etc.), Level Sensors / Float Switches in Treated Water & Raw Water Tanks and Control Cabling / Wiring between Level Sensors / Float Switches and Control Panel, Delivery Manifold, Isolating Valves, Non Return valves, Pressure Gauge, Fittings, Stainless Steel (Grade:304) Lifting Chains, Accessories etc. all as per Technical Specifications.\nThe Control Panel shall be capable operating the pumps (starts and stops) by sensing the level difference in water in the Treated Water Tank. Also; capable of ‘not starting or stopping the running pumps', when the water in the underground Raw Water Tank goes below the pre-set minimum level. \nThe Pumps to be installed in the Underground Raw Water Tank and Common Control Panel in the Pump Room, in Basement Floor, approx. 100 Mtr. away from Raw Water Tank. The Underground Power Cabling between Pumps and Control Panel and Control Cabling between Control Panel & Level Sensor / Float Switch, in the Underground Raw Water Tank, shall be measured as a part of Electrical Work. The Quoted Price for the Pump Set shall be inclusive of all above requirement, necessary Level Sensors / Float Switches, Power Cabling, Control Cabling etc, except what measured as a part of Electrical Work, as detailed above. | 1 | Set | |
1049 | 24.197 | Providing, Fixing, Testing and Commission Submersible Type Storm Water Transfer Dewatering Pump Set, complete set with 1 working + 1 Standby Submersible non- clog pump , Solids handling: 40mm , and with Common Control Panel for auto and cyclic operation. Capacity 12 M3/Hr. at 10 Mtrs. head, each, with 1.0 / 1.1KW, Single / Three Phase (all as per selection of pump without change in minimum duty conditions), with float switches/level sensors etc. necessary control valves, fittings and accessories, for discharging rain water from collection pits in basement floor, to lower strata. The price shall inclusive of all connected electrical work as detailed in the technical specification. For Pump Room | 1 | Set | |
1050 | 24.198 | Supply, Installation, testing and commission Water Pre-Treatment Plant Capacity: 20M3 /Hr, for continuous operation of 10 Hr, complete with High Pressure Sand Filter, Activated Carbon Filter,with Multiport valves, Chemical Dosing etc as per final requirement, connected Pipe Work etc, all as per Technical Specifications.Filter Feed Pumps shall be measured seperately. | 1 | Set | |
1051 | 24.199 | Supply installation, testing and commissioning of Sewage Treatment Plant of 300 KLD capacity \n(Detailed Technical Specification Attached)\n | 1 | Set |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail