| 1 | 1.1 | OFC schedule rates | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.12 | Excavating trenches up to 165 cm and back filling the excavated trenches after laying the HDPE pipe with or without protection rate for 1 in Non Rock strata | BI01010001010000000000000515BI0100001113 | 9200 | meters |
|---|
| 3 | 1.13 | 2 in Rocky-soil strata | BI01010001010000000000000515BI0100001114 | 9200 | meters |
|---|
| 4 | 1.14 | 3 in Hard Rock strata | BI01010001010000000000000515BI0100001115 | 4600 | meters |
|---|
| 5 | 1.2 | For HDPE pipe laying coupled with HDPE sockets and drawing of 6mm PP rope through it. | BI01010001010000000000000515BI0100001116 | 23000 | meters |
|---|
| 6 | 1.3 | Horizontal Boring at depth of 1.65 mtrs. For crossing roads/railway track. Inserting 100/65/40 mm dia GI pipes and pushing HDPE pipes/coils inside and Drawing 6mm PP rope. Based on market survey. | BI01010001010000000000000515BI0100001117 | 200 | meters |
|---|
| 7 | 1.4 | Laying and fixing of 65 /40mm G.I. Pipes in trenches with HDPE Pipes/Coils inside and drawing PP rope. | BI01010001010000000000000515BI0100001118 | 23500 | meters |
|---|
| 8 | 1.5 | Laying and fixing of G.I. Pipes of 100/65/40 mm on Bridges and culverts with HDPE Pipe/Coils. | BI01010001010000000000000515BI0100001119 | 150 | meters |
|---|
| 9 | 1.6 | Laying OverHead Optical Fiber Cable including necessary fittings and jungle cutting | BI01010001010000000000000515BI0100001120 | | |
|---|
| 10 | 1.61 | Supply of Binding wire 75 Lbs G.I.Wire | BI01010001010000000000000515BI0100001121 | | |
|---|
| 11 | 1.62 | Supply of 1''/32mm dia.Green flexible pipe,if required | BI01010001010000000000000515BI0100001122 | | |
|---|
| 12 | 1.63 | Laying ,fixing and sealing of full round 100/65/40 mm RCC Pipes with HDPE pipes/coils/inside and drawing PP rope | BI01010001010000000000000515BI0100001123 | 250 | meters |
|---|
| 13 | 1.64 | 2 Laying of 100 mm full round RCC pipe ISI mark (NP-2 class) 2 meter length ISI 458-2003 (revised upto date). | BI01010001010000000000000515BI0100001124 | 300 | meters |
|---|
| 14 | 1.7 | Laying RCC protection at site (DSR 1997 based) Market Rate for 1:2:4 at site | BI01010001010000000000000515BI0100001125 | 50 | meters |
|---|
| 15 | 1.71 | 12 SWG; width 120 cm in roll of 50 meters each (Based on market survey) | BI01010001010000000000000515BI0100001126 | | |
|---|
| 16 | 1.8 | Opening of man holes, pulling of OF cable, sealing of HDPE pipes in manholes by rubber bushes and providing HDPE/RCC split pipes in manholes and back filling of manholes and putting rope in PLB pipes | BI01010001010000000000000515BI0100001127 | 50 | meters |
|---|
| 17 | 1.9 | Splicing/Termination of Optical Fibre Cable 12/24/48/96 F Based on market rates. | BI01010001010000000000000515BI0100001128 | 30 | per Joint/termination |
|---|
| 18 | 2 | Digging of pits for jointing chamber, construction of brick chamber, filling of brick chamber with clean sand, supply and placing of pre-cast RCC slabs on brick chamber and back filling of jointing pit. Based on market rates. | BI01010001010000000000000515BI0100001129 | 60 | Per jointing chamber |
|---|
| 19 | 2.1 | Splicing/Termination of Optical Fibre Cable 48 F Based on market rates. | BI01010001010000000000000515BI0100001130 | 20 | per Joint/termination |
|---|
| 20 | 2.2 | Digging of pits 1m towards jungle side on each manholes/joint chamber for fixing of route/joint indicator, fixing & concreting of routes/joint indicator, painting & sign writing of route/joint indicators. | BI01010001010000000000000515BI0100001131 | | |
|---|
| 21 | 2.3 | Documentation 6sets of bound documents | BI01010001010000000000000515BI0100001132 | 50 | Lump sum |
|---|
| 22 | 2.4 | Cost of recovery of empty cable drums Optical fiber drum (6/12/24/48/96F) | BI01010001010000000000000515BI0100001133 | 10 | Per drum |
|---|
| 23 | 2.5 | Laying of half round 100mm RCC pipe in trenches with HDPE pipe/PLB coils inside and drawing PP rope. | BI01010001010000000000000515BI0100001134 | 100 | Per meter |
|---|
| 24 | 2.6 | Supply of route indicator/ Joint indicator | BI01010001010000000000000515BI0100001135 | 46 | Per unit |
|---|
| 25 | 2.7 | Getting required way leave permission from local authorities i.e. National/State highways, Local Municipal etc.( Necessary payment to authorities will be made by BSNL Solapur) | BI01010001010000000000000515BI0100001136 | | |
|---|
| 26 | 2.8 | Supply of SJC/BJC OFC Spilce Joint Closure of TSPC/QA/GR specification of BSNL | BI01010001010000000000000515BI0100001137 | 17 | Per unit |
|---|
| 27 | 2.9 | Road restoration work with cement concrete 1:4:8 mix for thickness varying from 150mm to 225mm including supply of concrete to evenly match road | BI01010001010000000000000515BI0100001138 | | |
|---|
| 28 | 3 | Road restoration work with bituminous for semi grouting 50mm thick & premix carpet surfacing 25mm thick over the ground surface( total upto 75m thick), including supply of asphalt etc. to evenly match road, including consolidation and road. | BI01010001010000000000000515BI0100001139 | | |
|---|