Military Engineer Services-MES has published Special Repairs To Building No P-121/7 122/8 ( 02 X Ors Md Accn ) At Jk Road Of Hq Sott Provn Of 06X Collepsible Gate And Window Grill At Bldg No P-218 Provn Of Fall Celling At Bldg No P-287 Sandmodle Room Of Saw Bld No P-190 Mil Exchange Spl Repai. Submission Date for this Tender is 03-06-2020. Building Repair Tenders in Ahmdnagar Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 24-Mar-2020 | Amendmentletter8411-3 | Date | 04-04-2020 |
2 | 30-Mar-2020 | Amendmentletter8411-4 | Date | 20-04-2020 |
3 | 15-Apr-2020 | Amendmentletter8411-5 | Date | 06-05-2020 |
4 | 05-May-2020 | Amendmentletter8411 | Date | 19-05-2020 |
5 | 18-May-2020 | Amendmentletter8411-8 | Date | 03-06-2020 |
6 | 27-May-2020 | Revised Tender Documents-2 | Other | 03-06-2020 |
Name of Work : Special repairs to bldg No P-121/7 & 122/8 (02 x OR's Md Accn) at J K Road of HQ Sott,Provn of 06x collepsible gate and window grill at Bldg No P-218, Provn of fall celling at Bldg No P-287 sandmodle room of SAW & Bld No P-190 Mil Exchange, Spl repair to Drainage line near Armt wg P-346 and P-1A of Demo coy, repair to toilet of Ground floor Bld No P-174 Elect Wg, Repair to sewage line and Manholes near Bldg No P-318 of DMR and Provn of Hard standing at Station officers Mess under AGE B/R-I, GE(N) Ahmednagar | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortor all as directed. | 26.5 | X Sqm | |
2 | 2 | Dismantling hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises all as directed. | 92 | Sqm | |
3 | 3 | Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) all as specified. | 91.85 | Cum | |
4 | 4 | M&L for 75mm thick PCC 1:3:6 type D-2 using 40mm graded stone aggregate as in sub base f all as specified and directed. | 265 | Sqm | |
5 | 5 | M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed. | 105 | Sqm | |
6 | 6 | M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm on vertical surfaces such as skirting over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed. | 18 | Sqm | |
7 | 7 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed. | 80 | Sqm | |
8 | 8 | M&L for glazed ceramic coloured tiles of size 350 x 250 x 7 mm thick on vertical surfaces such as dados over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed | 92 | Sqm | |
9 | 9 | M&L machine cut cudappa stone slab 20-25 mm thick over cement screed base, laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing all as directed. | 11.1 | Sqm | |
10 | 10 | M&L for granite(of any type) work(table rubbed and polished) cooking platform and like set in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to matach with shade of granite thickness of granite 18 to 20mm complete all as specified and directed. | 7.1 | Sqm | |
11 | 11 | M&L Machined pressed precast concrete interlocking paver block glossy finished with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over a stone dust cushion of 30mm thick all as directed. | 140 | Sqm | |
12 | 12 | M&L for Shahabad stone 20mm to 25mm thick flooring all as specified and directed. | 40 | Sqm | |
13 | 13 | Surface excavation not exceeding 30 cm deep in hard/dense soil and averaging 15 cm deep and getting out complete all as specified and directed | 70 | Sqm | |
14 | 14 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil | 222 | Sqm | |
15 | 15 | Excavation in trenches exc 1.5m wide and not exc 3m in depth for foundation etc or for walls, shafts, manholes not exc 10 Sqm on plan and getting out, in soft/loose soil complete all as directed | 14 | Cum | |
16 | 16 | M&L for Cement concrete 1:4:8 Type D2 (40 mm graded stone aggregate in foundations, filling and mass-concrete in lean concrete of drain | 91 | Cum | |
17 | 17 | Demolition of cement concrete (un-reinforced) ,of any description, in any position, from the foundation of manhole including benching etc. complete all as specified. | 12 | Cum | |
18 | 18 | Demolition of reinforced cement concrete of any description and in any position not otherwise provided for including reinforced cut as required to facilitate demolition complete all as directed. | 55 | Cum | |
19 | 19 | Demolition and breaking up 100 mm bore drain pipe i.e. salt glazed ware, AC or reinforced concrete pipe , set in cement mortar complete all as specified and as directed . | 100 | Cum | |
20 | 20 | All as per item above but 200mm bore pipe | 480 | RM | |
21 | 21 | Material & labour for 150 mm bore Reinforced cement concrete pipe, type NP2 , haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40mm graded mechanically crushed stone aggregates and making necessary connection after cutting into existing sewer line/manhole to make it functional complete all as specified. for the following :- . \nNote :- (i) Cutting into existing sewer line/manhole shall be measured & paid seperately.\n(ii) Excavation & earth work shall be measured and paid separetely once either while demolition or white laying SGSW pipe. | 120 | RM | |
22 | 22 | Material & labour for 200 mm bore Reinforced cement concrete pipe, type NP2 , haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40mm graded mechanically crushed stone aggregates and making necessary connection after cutting into existing sewer line/manhole to make it functional complete all as specified. | 480 | RM | |
23 | 23 | Material and labour for reinforced cement concrete 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregates as cover slab for drain or manhole including necessary form work and making holes 25 mm dia @ 150 mm centre to centre, set and jointed in cement mortar 1:6 complete all as specified and as directed. | 2.1 | RM | |
24 | 24 | M&L for PCC 1:3:6 type C-1 using 20mm graded mechanically crushed stone aggregates as in cills, steps, bands, copings, bed plates, kerbs, hold fasts blocks etc including weathering slightly rounded or chamfered angles of throating including form work complete all as specified. | 1 | Cum | |
25 | 25 | Material and labour brick work with fly ash straight or curved on plan exc 6m mean radius, built in built in cement mortar 1:6 complete all as specified and directed. | 10 | Cum | |
26 | 26 | Material & Labour for rendering 10 mm thick in CM 1:4 on concrete surfaces of wall finished even & smooth without using extra cement mixed with water proof compound @ 3 % of the weight of cement as per the manufecturer's instructions complete all as specified and directed.\n Note :- WPC shall be measured and paid separetely.\n | 42 | Cum | |
27 | 27 | Supply only integral water proofing compound complete all as specified. | 12.4 | Sqm | |
28 | 28 | Cutting into existing manholes for connecting new drains 200mm internal dia of pipe making good to pipe abd rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooh finished and reforming benching as required all as specified. | 12 | Kg | |
29 | 29 | Cutting into existing manholes for connecting new drains 150mm internal dia of pipe making good to pipe abd rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooh finished and reforming benching as required all as specified. | 6 | Each pipe | |
30 | 30 | Supply and fixing precast Hume pipe septic tank of capacity 25 users incl necessary excavation and earthwork in any tpe of strata all as specified and directed by Engr-in-Charge | 4 | Each pipe | |
31 | 31 | Surface dressing n. exc 15 cm deep and removal of wild groth / shurps, roots, incl spraying of deweding chemical 1 m each side on both sides along sewage line all as directed by Engr-in -Charge | 150 | Each | |
32 | 32 | M&L for Pre-cast cement concrete block masonry Type C1 1:3:6 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar Set in cement mortar 1:6, complete | 72 | Sqm | |
33 | 33 | M&L for rendering 15mm thick plaster on fair faces of brick work or concrete surfaces to be finished even and smooth (without using extra lime or cement in CM 1:4 complete all as specified. | 226 | Cum | |
34 | 34 | M&L for PCC 1:2:4 type B1 as in coping including necessary formwork, weatherig, slightly rounded or chamfered angle and throating all as specified and directed. | 4 | Sqm | |
35 | 35 | Returning , filling in including in spreading , leveling,watering and well raamming in layers.n exc 25 cm in soft/loose soil | 164 | Cum | |
36 | 36 | Removing surplus & soil to a distance exc. 250 m but n exc. 500 m & depositing where directed by engineer - in charge at a level n exc 1.5 mtr above the starting point complete all as specified | 268 | Cum | |
37 | 37 | M & L PCC 1:2:4, type B1 (using 20 mm graded agg) 40 mm thick as in flooring, finish even and smooth without using extra cement complete all as specified and directed. | 24 | Cum | |
38 | 38 | M & L PCC 1:3:6, type C2 (using 40 mm graded agg) 75 mm thick as in plinth protection complete all as specified and directed. | 30 | Sqm | |
39 | 39 | PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates as in surface channel & drain etc. complete all as specified. | 1 | Sqm | |
40 | 40 | M&L for form work to sides of concrete foundations, footings, bases of columns rafts and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work in fair finished surfaces complete all as specified and as directed | 49.5 | Cum | |
41 | 41 | M&L for RCC M-25 design mix using 20mm graded stone aggregate for foundations, including rafts, footings, foundation beams, plinth beams; bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and as directed | 9.1 | Sqm | |
42 | 42 | M& for form work to sides of pillars, posts, struts, piers, columns and stanchions on fair finished surfaces etc complete all as specified and as directed. | 39.1 | Cum | |
43 | 43 | M&L for RCC M-25 design mix using 20mm graded stone aggregate for columns, pillars, piers, posts and struts complete all as specified and as directed | 3 | Sqm | |
44 | 44 | M&L for form work to sides and soffits of beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves etc in fair finished surface complete all as specified and as directed | 24.6 | Cum | |
45 | 45 | M&L for RCC M-25 design mix using 20mm graded stone aggregate for beams, canilevers, bressumers, lintels over 1.5m span complete all as specified and as directed | 1.65 | Sqm | |
46 | 46 | M&L Form work soffits of suspended slab such as roof slabs, floor slabs landings and similar work not exceeding 200mm thick horizontal or sloping in fair finished surfaces complete all as specified and directed. | 20.6 | Cum | |
47 | 47 | M&L for RCC M-25 design mix using 20mm graded stone aggregate for slabs supported on walls and columns in floors, roof, landings, balconies, canopies, deck slabs and in shelves complete all as specified and as directed | 3 | Sqm | |
48 | 48 | Material and labour for water proofing treatment over RCC slab by applying one coat of bituminous primer @ 0.25 Kg / Sqm and providing 3mm thick APP modified water proofing membrane weighting not less 3.5 Kg / Sqm, reinforced with non woven polyster reinforcement mat weighing not less than 160 gm / Sqm, polyster core having softening point not less than 150 degree C, longitudinal tensile strength not less than 650 N / 5 cm, tearing strength of 180 N / 5 cm including a coat of solar reflective aluminium paint @ 0.15 Kg / Sqm including cleaning the newly plastered surfaces of concrete / existing plastered vertical surfaces with with wire brushes free from dust etc all as sepecified and directed. | 30 | Cum | |
49 | 49 | Material and labour for soild block masonry built with plain cement concrete (1:5:8) solid blocks, type C5, using 40 mm graded aggregates built in cement mortar 1:6 all as directed. | 12.2 | SQM | |
50 | 50 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n. exc 15 cm thick spread, levelled and rammed including watering complete all as specified and as directed. | 33.8 | CUM | |
51 | 51 | M&L Hardcore of guage n. exc 63mm, of broken stone or boulders deposited, spread and levelled in layers n.exc 15cm thcik, watered and rammed to a true surface all as specified and directed. | 24.1 | Cum | |
52 | 52 | M&L for PCC 1:4:8 type D2 using (40mm graded stone aggregate) as in flooring, 100mm thick etc all as specified and directed.\n | 89.5 | Cum | |
53 | 53 | M&L mild steel TMT bars 10 mm dia and over cut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed | 1520 | Sqm | |
54 | 54 | Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water all as directed | 260 | Kg | |
55 | 55 | M&L for two coats of cement base paint on newly / old plastered surfaces incl preparation etc. complete on wall | 56 | Sqm | |
56 | 56 | M&L for rendering, 15 mm thick on stone/Brick masonry surfaces, concrete surface in cement mortar 1:4 on wall or roof finished even and smooth without using extra cement all as sepecified and directed. | 80 | Sqm | |
57 | 57 | M&L for rendering, 15 mm thick on stone/Brick masonry surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement with sagol finish all as sepecified and directed. | 130 | Sqm | |
58 | 58 | M&L for rendering, 10 mm thick on concrete surfaces in cement mortar 1:4 on ceiling finished even and smooth without using extra cement with sagol finish all as sepecified and directed. | 50 | Sqm | |
59 | 59 | M&L for rendering 15mm thick plaster on walls in CM (1:6), on fair faces of brick work or concrete surfaces, finish the surfaces even & fair complete all as specified and as directed | 108 | Sqm | |
60 | 60 | M&L for two coats of oil bound distemper on newlyplastered surfaces of walls paint over 3mm thick wall care putty including preparation of surfaces all as directed. | 140 | Sqm | |
61 | 61 | M&L for complete removal of existing treatment and two coats of OBD over 3 mm thick wall care putty on plastered surfaces of walls including preparation of surfaces all as directed. | 500 | Sqm | |
62 | 62 | M&L for 3 coats of white wash on newly plastered surfaces incl preparation etc. complete on wall. | 150 | Sqm | |
63 | 63 | M&L for 3 coats of white wash on newly plastered surfaces incl preparation etc. complete on ceiling. | 74 | Sqm | |
64 | 64 | Material and labour for special treatment to sunken slab floor incl WC trap etc including cleaning and preparing the surface area for carrying out membrane water proofing treatment, then injection grouting the weak areas on the concrete surface with cementitious grout and applying 10mm thick cement plaster in CM 1:4. Then providing and laying Mineral Top APP (Atactic Polypropylene Polymer) modified prefabricated 5 layer 4mm thick water proofing membrane, black finished rainforce with non woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Litre per Sqm by the same membrane manufacturer of density at 25ºC, 0.87-0.89 Kg per litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torach and sealing all joints etc and preparing the surface complete. and providing PCC 1:5:10 type E2 using 40mm graded mechanically crushed stone aggregates in sunken slab and 75mm thick PCC 1:4:8 type D2 using 40mm graded mechanically crushed stone aggregates as base, 40mm bore GI pipe, light grade of length not less that 50 cm as spout, non-skid glazed tiles as per existing pattern/size/tint with and incl WC viterous china squatting pan 580x440mm with integral footrests/pedastal pan incl seat cover, white, area of WC exc 1.00 Sqm but nexc 5.00 Sqm etc after dismantling the existing sunken floor etc complete all as specified and as directed.\nNote : Work has to be carried out strictly by the authonticated applicator of the manufacturer and as per manufacturers specification as approved by GE.\n | 5 | Each | |
65 | 65 | Taking down steel windows / ventilators, of any description and size Each all as directed. | 14 | Each | |
66 | 66 | Taking down chowkhats or frames n exc 1.5 sq. m Each with shutters (without taking off shutters from the frame) | 6 | Each | |
67 | 67 | Taking down shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm Each all as directed. | 6 | Per Leaf | |
68 | 68 | Supplied and welding standard projecting/box, butt hinges for steel windows inn repairs all as specified & directed. | 4 | Each | |
69 | 69 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed.\nNOTE: Wire cloth, glass, guard bars and painting shall be measured and paid separately. | 8 | Sqm | |
70 | 70 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.\nNOTE: Wire cloth, glass, guard bars and painting shall be measured and paid separately. | 6 | Sqm | |
71 | 71 | S&F stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as directed. | 24 | Sqm | |
72 | 72 | All as per item No 26 above but fixed in repairs. | 4 | Sqm | |
73 | 73 | S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as directed. | 8.15 | Sqm | |
74 | 74 | S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) all as directed. | 8.15 | Sqm | |
75 | 75 | Material and labour for false ceiling with 4 mm thick plain non asbestos building 'E' board with decorative finish water proofed on one side fixed on and including powder coated GI fabricated grid of 60 cm X 60 cm made out of main runner of 'T' section of size 32 mm X 24 mm X 0.30 mm, cross runner made out of 'T' of section of size 24 mm X 24 mm X 0.30 mm and alround angular section of size 22 mm X 22 mm X 0.70 mm with GI clip and level adjuster duly suspended by 4 mm dia GI wire fixed to roof at 1200 mm centre to centre as per manufacturere's instructions and all as directed | 1030 | Sqm | |
76 | 76 | S&F powder coatedd anodised aluminium frame for door windows ventilator with more rebetes incl joining cleats for fixing etc, all as specified | 170 | Kg | |
77 | 77 | S&F powder coatd anodised aluminium windows ventilator shutter, fixed type without sashbar alum section wt 0.55kg/m incl necessary joining cleats glazing clips, rubber packing anodised aluminium snap beading, screas etc complete all as specified | 74.1 | Sqm | |
78 | 78 | S&F 4.0mm thick sheet glass ordinary quality & glazing with solar control filim 50 micron thick reflective type sticked to glass panes as per instruction of manufactures exc 0.50 sqm in each pane etc. | 24.4 | Sqm | |
79 | 79 | S&F anodised aluminium door shutter aluminium section weighing 0.55 kg/m including necessary joining cleat, glazing rubber neoprene packing, handles 2 Nos in each door, hinges anodised alumunium snap beading screw etc. complete all specified. | 12.1 | Sqm | |
80 | 80 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing all as specified and directed. | 18.4 | RM | |
81 | 81 | S&F factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails frame shall be covered with heat moulded plain coloured PVC `C' channel having a PVC sheet strip of 20 mm width stuck and plain colour PVC sheets for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame all as directed. | 12.1 | Sqm | |
82 | 82 | S&F in repair pressed steel frames (Size 125 x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed. | 5.1 | RM | |
83 | 83 | S&F in aluminium anodized grill of design DG 104 pattern made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm &1.4mm thick all as per manufactures instructions complete all specified & directed. Make of grill Deco grill or equivalent | 218 | Sqm | |
84 | 84 | S&F Collepsible steel gates, top hunge, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, at specified, erected in positioin and scuring runners with holdfasts and brackets complete all as specified and directed. | 34.5 | Sqm | |
85 | 85 | S&F mild steel 10 mm square bar to steel windows/ventilators as in guard bar conforming to Fe-290 Gde E-165 all as specified and directed. | 40 | KG | |
86 | 86 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones all as specified and directed. | 29 | Sqm | |
87 | 87 | M&L for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in Each pane all as directed. | 21.5 | Sqm | |
88 | 88 | M&L for glazing with 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in Each pane as as directed. | 7.5 | Sqm | |
89 | 89 | S&F 100 mm long butt hinge, medium weight, cold rolled mild steel all as directed. | 22 | Each | |
90 | 90 | S&F 100 mm long butt hinge, medium weight, stainless steel all as directed. | 28 | Each | |
91 | 91 | S&F 200 mm long mild steel barrel tower bolt, stove enamelled black, with bright bolt all as directed. | 12 | Each | |
92 | 92 | S&F 150 mm long mild steel pressed handles, oval type, stove enamelled black all as directed. | 10 | Each | |
93 | 93 | S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate all as directed. | 12 | Each | |
94 | 94 | S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections all as directed. | 24 | Each | |
95 | 95 | S&F 150 mm long aluminium anodised handle, cast type all as directed. | 24 | Each | |
96 | 96 | S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring all as directed. | 2 | Each | |
97 | 97 | M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer all as specified. | 6 | Sqm | |
98 | 98 | M&L preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint all as specified. | 40 | Sqm | |
99 | 99 | M&L plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc 3 & n.exc 6 Sq.cm of 2nd class hard wood all as specified. | 10 | RM | |
100 | 100 | S&F in repair harrison rails, mild steel, chromium plated decorative powder coated curtain rods with fixing brackets, stops, rollers etc. all as specified and directed. | 30 | RM | |
101 | 101 | S&F Mild steel TMT bars 6mm to 8mm dia in distribution, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips incld cutting & removal of old decayed reinforcement | 840 | Kg | |
102 | 102 | Dismantling of water tanks of capacity exc 500 ltrs but n.exc 1000 ltrs and removing from site all as specified and directed. | 3 | Each | |
103 | 103 | S&F rotational moulded polythene water storage tank 1000 ltr capacity vertical with closed top hoisted and fixed in position all as specified in SSR part-I. | 3 | Each | |
104 | 104 | S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed all as specified and as approved by GE/Engineer-in-Charge. | 4 | Each | |
105 | 105 | S&F ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe all as specified and directed. | 4 | Each | |
106 | 106 | Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe all as directed. | 80 | RM | |
107 | 107 | All as per item No above but 20mm dia pipe. | 40 | RM | |
108 | 108 | S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as directed. | 80 | RM | |
109 | 109 | All as per item No above but 20mm dia pipe. | 40 | RM | |
110 | 110 | Taking down rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overalll as fixed along the cente line over fittings and accessories) | 14 | RM | |
111 | 111 | S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls all as directed. | 18 | RM | |
112 | 112 | S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls all as directed. | 14 | RM | |
113 | 113 | S&F 75 mm dia PVC (SWR) vent cowl all as directed. | 12 | Each | |
114 | 114 | S&F 110 mm bore PVC (SWR) branch piece double (single Y) equal or unequal all as directed. | 7 | Each | |
115 | 115 | S&F 110 mm dia PVC (SWR) bend any radius all as directed. | 11 | Each | |
116 | 116 | S&F 75 mm dia PVC (SWR) bend with access door any radius all as directed. | 13 | Each | |
117 | 117 | S&F PVC (SWR) floor trap, 75 mm dia with grating including jointing with solvent cement etc all as directed. | 12 | Each | |
118 | 118 | S&F in repair chromium plated grating 100mm dia | 8 | Each | |
119 | 119 | S&F in repair, Bib tap 15 mm dia, fancy type chromium plated, cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe or for brass ferrule all as directed. | 16 | Each | |
120 | 120 | S&F Pillar taps 15mm dia, cast copper alloy, with capstan heads, chromium plated, screwed own high pressure, with/without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe & fixed | 9 | Each | |
121 | 121 | S&F in repair, 15 mm dia stop valve, fany type chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe all as directed. | 10 | Each | |
122 | 122 | S&F in repairs, shower rose, 125 mm size, brass chromium plated with sweivel joint all as directed. | 2 | Each | |
123 | 123 | S&F in repairs, aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges all as directed. | 4 | Each | |
124 | 124 | S&F in repairs 32 mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors all as directed. | 12 | RM | |
125 | 125 | S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe and connection to pipe all as directed. | 5 | Each | |
126 | 126 | S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe incl. plastic water closet seat black closed pattern with flat bottom & cover & mild steel chromium plated etc. | 3 | Each | |
127 | 127 | S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including conncetion to flushing pipe and waste pipe providing and fixing plugs bedding urinal against wall all as specified and directed . | 3 | Each | |
128 | 128 | S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor all as specified and directed. | 2 | Each | |
129 | 129 | S&F fixed Wash hand basin vitreous china (flat back) size 450 x 300 mm including brackets waste brass chromium plated with long screwed shanks and fly nuts 32 mm size including bottle trap complete all as specified and directed. | 4 | Each | |
130 | 130 | S&F in repairs looking mirror of selected quality of size 600 mm X 450 mm with bevelled edge mounted 6 mm thick commercial plywood and aluminium channel of required size fixed to wooden plugs with chromium plated brass screws and cup washers all as directed. | 4 | Each | |
131 | 131 | S&F in repair stainless steel kitchen sink 0.63 mm thick or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm all as specified and directed | 2 | Each | |
132 | 132 | S&F in repair stainless steel plate rack 0.63mm thick sheet for kitchen ( Size 31"x 36' x 10') all as specified and directed. | 2 | Each | |
133 | 303 | Taking down carefully aluminium point wiring (light, fan, bell, socket, power point etc.) with or without conduit, casing caping, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete all as specified and directed by Engineer-in-Charge | 1.25 | Cum | |
134 | 304 | M & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn through and including PVC casing & capping with necessary accessories with Flush steel mounting boxes of mylanic series of Legrand and white plates with frame of myleic series of Legrand of suitable size required at site. housing of switches sockets / fan regulator etc. including 1.5 Sqmm single core solid multitranded copper conductor FRLS 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth & connecting to earth dolly for the following :- (Note :- The cost of Mudular mounting boxes and modular plates included in the quatated rates) | |||
135 | 305 | (a) One light point controlled by one, one way switch single pole. | 2 | Kg | |
136 | 306 | (b) One Fan point controlled by one, one way switch single pole. | 23 | Sqm | |
137 | 307 | (c) One bell point controlled by one bell push on independent board. | 1 | Sqm | |
138 | 308 | (d) One 3 pin 5 Amps socket out let on independent board | 33 | Sqm | |
139 | 309 | (e) One 3 pin 5 Amps socket out let on Sameboard | 59 | Sqm | |
140 | 310 | All as per item No 2 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board. | 40 | Cum | |
141 | 311 | S & F 6 A one-way SP switch - 1 module of Make Legard Cat No: 6755 01 or equvalent in Simens / Carbtree all as specified and directed. | 215 | Sqm | |
142 | 312 | S & F 16 A one-way SP switch - 1 module of Make Legard Cat No: 6755 11 or equvalent in Simens / Carbtree all as specified and directed | 32 | Cum | |
143 | 313 | S & F 6 A 3 pin universal socket 2 modules of Make Legard Cat No: 6755 50 or equvalent in Simens / Carbtree all as specified and directed. | 82 | Cum | |
144 | 314 | S & F 6/16 A socket 3 Pin 2 modules module of Make Legard Cat No: 6755 55 or equvalent in Simens / Carbtree all as specified and directed. | 32 | Cum | |
145 | 315 | S & F 6 A one-way SP bell push - 1 module SP switch - 1 module of Make Legard Cat No: 6755 04 or equvalent in Simens /Carbtree all as specified and directed. | 1 | Each | |
146 | 316 | S & F Fan regulator 100 W with 2 module of Make Legard Cat No: 6755 30 or equvalent in Simens /Carbtree all as specified and directed. | 23 | Each | |
147 | 317 | S&F bell, AC, 230 Volts, single pole all as specified and directed.Make: Anchor / Havells / Standard | 1 | EACH | |
148 | 318 | S&F ceiling rose surface bakelite three terminal all as specified and directed. Make : Anchor/Havells/Standard | 124 | EACH | |
149 | 319 | S&F Lamp holder Lamp holder with LED Lamp 07 Watt of Make Havells/CG/Wipro all as specified and directed.Make : Anchor/Havells/Standard | 31 | EACH | |
150 | 320 | S & F in replacement double door Sheet metal enclosures factory made DBs 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No: 5076 11 or equivalent in Simens/ Hager/ L & T | 4 | EACH | |
151 | 321 | S & F in replacement double door Sheet metal enclosures factory made DBs 4 way , 415 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 70 or equivalent in Simens/ Hager/ L & T | 4 | EACH | |
152 | 322 | S & F MCBs of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) (Note :- Make of the isolator should be the same as that of DB) for the following :- | |||
153 | 323 | (a) MCB Single Pole of 240 volts 5-32 Amps,10 KA Capacity, 'C' series of Make: Legrand ,Cat No: 4085-87 to 90,92,93,94,95 or equivalent in Simens/ Hager/ L & | 42 | Each | |
154 | 324 | (b) MCB Single pole + Neutral 240 volts, 32 -63 Amps,10 KA Capacity, 'C' series of Make: Legrand ,Cat No: 4086-17 to 20 or equivalent in Simens/ Hager/ L & T | 22 | SQM | |
155 | 325 | (c) MCB Triple pole + Neutral 415 Volts ,40 -63 Amps,10 KA Capacity, 'C' series of Make: Legrand ,Cat No: 4086-81 to 83 or equivalent in Simens/ Hager/ L & T | 4 | EACH | |
156 | 326 | Taking down Existing tube light fitting & Supply & fix Endura LED Batten fitting 20 watt with minimum 2000 lumen output with 6500 K including connecting up with thre core twisted flexible copper conductor cable with suitable size from ceiling rose to fitting all as directed by the Engr-in-Charge.Make :- Jaguar ,Cat No. LGLZ01X020XCPhilips ,or eq in Philips,Cat No. BN108C LED 20S PSU CDL WH /Havells ,Cat No. ENDURALINEARNEOBS20WLED830SPCWH | 80 | EACH | |
157 | 327 | Taking down Existing tube light fitting & Supply & fix Endura LED Batten fitting 10 watt with minimum 1000 lumen output with 6500 K including connecting up with thre core twisted flexible copper conductor cable with suitable size from ceiling rose to fitting all as directed by the Engr-in-Charge. Make :- Jaguar ,Cat No. LGLZ01X010XC/Havells Cat No ENDURALINEARNEOBS10WLED840SPCWH/Philips Cat No Astra Line Scene Switch 10 Watt/1000 Lumens | 13 | EACH | |
158 | 328 | Taking down Existing tube light fitting & Supply and fix in replacement 40 Watt with minimum 3100 lumen output with 6500K LED edge - lit luninaire suitable for armstrong / grid ceiling complete with separate electronic driver all as specified and direcrted by Engineer-in-Charge. Jaguar Cat Part LSVRO1S0XC / Wipro Cat No.LC-30 551-XXX-57-G1 / Havells Cat No.ENDURASLIMPROPLUS2X2PLR28/36WLED857MOD \n | 36 | EACH | |
159 | 329 | Taking out old building security light ( HPSV/Tube light fitting) & S & F LED bldg security light minimum 25 Watt with minimum 2500 lumens with 6500K and New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium roadway luminaire with high power LED as light source of capacity 25W LED 5000K of Make Jaguar Cat No.LTRUMP0025XC or Eq in / Havells Cat No. NDURAPEARLSL25WLED757SASYTOPCMP /Philips \nCat No BRP020 LED HP/CW 240V25W /Wipro Cat No.LR02-291-XXX-57-XX\n | 13 | EACH | |
160 | 330 | M & L for Earthing complete with galvanized steel earth plate electrode 60x60cm x 6.0 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including galvanised earth lead wire 4.0 mm dia,by means of nuts,bolts,checknuts and washers of galvanized iron including 15 mm bore GI pipe,medium grade up to 7.5 meters long all as shown in electrical plate No.3 of MES SSR part-I and testing on completion including excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber,precast RCC slab 50mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM,( weight not less than 4 Kg/Sqm), with cast iron frame, funnel with wire mesh,GI watering pipi 20 mm dia medium grade,test point and lugs complete.\nNOTE:-(i) Items includes the cost of 7.5 metre length GI pipe and earth lead for protection of earth lead.Any variation in length shall be adjusted through deviation order.(ii) On testing,if the earth resistance is not obtained,earthing will be regenerated at no extra cost till the desired earth resistance is obtained. | 4 | EACH SET | |
161 | 331 | M&L in replacement for sub main wiring with two runs of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through PVC Casing Caping and 2.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed (Note : Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) | 215 | RM | |
162 | 332 | Supply and fix in replacement industrial type switch socket for Geysers with 20 Amps MCB Make:- Iengard Cat No.6078 41 20 A SP complete or Eq in L & T /Hager | 10 | EACH | |
163 | 333 | M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :- (Make :- Polycab/Havells/ CCI) | |||
164 | 334 | (a) LT cable25 Sqmm 4 core. | 185 | RM | |
165 | 335 | Supply and fix heavy duty exhaust fan ,300 mm sweep,230 V,50 Hz with fixing of fan duly grouted in bolts and connecting with 3 core flexible copper cable of size 1.5 Sqmm all as directed including making holes /Addn/Altn to in wall / window of Make ; Havells ,Cat No Turbo force / Orient /CG | 1 | Each | |
166 | 336 | An amount of Rs 42,589.00 shall be deducted from BOQ on account of schedule of credit |