Job Order Maintenance And Operation Of Htl , Whjbc , Pms , Igloo , Dbm Air Conditioner Plants Including Cold Room And Cool Room At Naval Base Karwar Under Ge Sb Karwar, GE (Seabird), Naval Base, Karwar-Karnataka

Military Engineer Services-MES has published Job Order Maintenance And Operation Of Htl , Whjbc , Pms , Igloo , Dbm Air Conditioner Plants Including Cold Room And Cool Room At Naval Base Karwar Under Ge Sb Karwar. Submission Date for this Tender is 03-03-2020. HVAC Tenders in GE (Seabird), Naval Base, Karwar Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

23762854
Job Order Maintenance And Operation Of Htl , Whjbc , Pms , Igloo , Dbm Air Conditioner Plants Including Cold Room And Cool Room At Naval Base Karwar Under Ge Sb Karwar
Open Tender
Indian
Karnataka
GE (Seabird), Naval Base, Karwar
03-03-2020

Tender Details

Job Order Maintenance And Operation Of Htl , Whjbc , Pms , Igloo , Dbm air conditioner Plants Including Cold Room And Cool Room At Naval Base Karwar Under Ge Sb Karwar

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 2.96 Lakhs /-

BOQ Items

Name of Work ;MAINTENANCE & OPERATION OF AC PLANTS AT MEWR, BGRP, WED, NSD AND INHS PATANJALI AND DG SET “MAINTENANCE / OPERATION OF HTL, WHJBC, PMS, IGLOO, DBM AC PLANTS INCLUDING COLD ROOM AND COOL ROOM AT NAVAL BASE KARWAR UNDER GE (SB) KARWAR.18 Days
Sl. No. Item Description Item Code / Make Quantity Units
1 1 MAINTENANCE & OPERATION OF AC PLANTS AT MEWR, BGRP, WED, NSD AND INHS PATANJALI AND DG SET “MAINTENANCE / OPERATION OF HTL, WHJBC, PMS, IGLOO, DBM AC PLANTS INCLUDING COLD ROOM AND COOL ROOM AT NAVAL BASE KARWAR UNDER GE (SB) KARWAR."\n1. The maintenance works as mentioned below is proposed to be carried out for provisioning of services for operation and routine maintenance of AC installations at (Site ‘E’) :- (For \n18 days)\n2 .Maintenance & operation of package type AC plant at HTL of capacity of 11 ton-02 Nos. ( 1 W ,1 S) Make: Blue Star, Model DPA-1052 S running daily 24 hrs. In 3 shifts for smooth functioning of entire system and to maintain specific temperature as directed complete. AC plants consists of the following accessories:- \na) Package type Air conditioning Plant sealed compressor condenser Model DPA 1052-02 Nos. (1 W,1S)\nb) Electric control panel cubical type main switches, starter voltmeter, ammeter contractors -01Set.\nc) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set.\nd) Sealed AHU with cooling coil and blower motor-02Set.\ne) Ducting for supply air with grills diffusers dampers per and re heater etc.-01Set. \n3.Maintenance & operation of central AC plant with package chiller condensing unit complete of 3 Nos. 26 Ton (Make:-BLUE STAR, Model No. LCWS2-026 at IGLOO complete with cooling tower, AHU & other accessories each for 24 hrs 3 shifts around the clock run daily \na) Water cooled package chiller unit model LCWS2-026 -03Nos. \nb) Chiller water pump motor Model ND-112 M capacity 5 hp, Make - Crompton Greaves -03Nos \nc) Chiller water pump set Model 2U1 capacity 83 USGPM at 25 Mtr head , Make Becon Weir Ltd -03Nos \nd) Condeser water pump set Model 2U1 capacity 83 USGPM at 25 Mtr head , Make Becon Weir Ltd -03Nos \ne) Condeser water pump motor Model ND-112M capacity 5 hp, Make - Crompton Greaves -03Nos \nf) Air handling unit model ESHW06-220 of capacity 22277 cmh with blower motor, cooling coil, heater bank, humidity and temperature controller, electric panel complete -02 No. Make - Blue Star\ng) FRP Cooling tower capacity 101 USGPM, Model No SM2/6C/1.5 with CT fan-03No. Make Mihir Engr Ltd\nh) Electrical control panel cubical type floor mounted with maint switch MCB's voltmeter, Ammeter, Starter Condenser etc. complete-01Set.\nj) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set.\nk) Digit type thermometer-01 Set \nl) Air supply duct with grill diffusers dampers and heater etc.complete-01 Set.\nm) Condenser piping MS 100/80/50mm dia with valves pressure gauge temperature gauge complete -1Set. \n4. Maintenance & operation of central AC plant with package chiller condensing unit complete of 3 Nos. 39 Ton (Make:-BLUE STAR, Model No. LCWS3-039 at DBM complete with cooling tower, AHU & other accessories each for 24 hrs 3 shifts around the clock run daily \na) Water cooled package chiller unit model LCWS3-039 -03Nos. \nb) Chiller water pump motor Model ND-112 M capacity 5 HP, Make - Crompton Greaves -03Nos \nc) Chiller water pump set Model 2U1 capacity 141 USGPM at 25 Mtr head , Make Becon Weir Ltd -03Nos \nd) Condeser water pump set Model BWC 50/80 capacity 141 USGPM at 25 Mtr head , Make Becon Weir Ltd -03Nos \ne) Condeser water pump motor Model ND-132S capacity 7.5 HP , Make - Crompton Greaves -03Nos \nf) Air handling unit model ESHW06-270 of capacity 29549 cmh with blower motor, cooling coil, heater bank, humidity and temperature controller, electric panel complete -02 No. Make - Blue Star\ng) FRP Cooling tower capacity 141 USGPM, Model No SM2/7.5C/2 with CT fan-03No. Make Mihir Engr Ltd-03 Nos\nh) Electrical control panel cubical type floor mounted with maint switch MCB's voltmeter, Ammeter, Starter Condenser etc. complete-01Set.\nj) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set.\nk) Digit type thermometer-01 Set \nl) Air supply duct with grill diffusers dampers and heater etc.complete-01 Set.\nm) Condenser piping MS 100/80/50mm dia with valves pressure gauge temperature gauge complete -1Set. \n\n\n 1 JOB
2 1.01 5. Maintenance & operation of central AC plant DX type condensing unit complete of 3 Nos. 30Ton (Make:-BLUE STAR, Model No. WCUS2-030 at PMS building, MTP complete with cooling tower AHU & other accessories each for 24 hrs 3 shifts around the clock run daily \na) Water cooled DX unit model WCUS2-030 -03Nos. \nb) Condeser water pump set Model 2U1 capacity 75 USGPM at 25 Mtr head , Make -Becon Weir Ltd -03Nos \nc) Condeser water pump motor Model ND-112 M capacity 5 HP, Make - Crompton Greaves -03Nos \nd) Air handling unit with blower motor, heater bank, cooling coil, electric control panel complete installed in AHU room -01 No. Make - Blue Star Model ESHX6-160 of 19440 cmh \ne) FRP Cooling tower capacity 75 USGPM, Model No SM1/9B/1.5 with CT fan-03No. Make Mihir Engr Ltd-03 Nos\nf) Electrical control panel cubical type floor mounted with maint switch MCB's voltmeter, Ammeter, Starter Condenser etc. complete-01Set.\ng) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set.\nh) Digit type thermometer-01 Set \nj) Air supply duct with grill diffusers dampers and heater etc.complete-01 Set.\nk) Condenser piping MS 100/80/50mm dia with valves pressure gauge temperature gauge complete -1Set. \n6. Maintenance & operation of central AC plant DX type condensing unit complete of 2 Nos. 30Ton (Make:-BLUE STAR, Model No. WCUS2-030 at WHJBC building, complete with cooling tower AHU & other accessories each for 24 hrs 3 shifts around the clock run daily \na) Water cooled DX unit model WCUS2-030 -02 Nos. \nb) Condeser water pump set Model 2U1 capacity 75 USGPM at 25 Mtr head , Make -Becon Weir Ltd -02 Nos \nc) Condeser water pump motor Model ND-112 M capacity 5 HP, Make - Crompton Greaves -02 Nos \nd) Air handling unit with blower motor, heater bank, cooling coil, electric control panel complete installed in AHU room -01 No. Make - Blue Star Model ESHX4-120 of 14076 cmh \ne) FRP Cooling tower capacity 75 USGPM, Model No SM1/9B/1.5 with CT fan-03No. Make Mihir Engr Ltd-03 Nos\nf) Electrical control panel cubical type floor mounted with maint switch MCB's voltmeter, Ammeter, Starter Condenser etc. complete-01Set.\ng) Control devices such as expansive valve thermostat solenoid valve HP/ LP/CP cut outs with panel board installed gauges-01 Set.\nh) Digit type thermometer-01 Set \nj) Air supply duct with grill diffusers dampers and heater etc.complete-01 Set.\nk) Condenser piping MS 100/80/50mm dia with valves pressure gauge temperature gauge complete -1Set. \n7.Maintenance & operation of Central AC Plant with package chiller condensing unit complete of 02 Nos working & 01 No Stand by, Each 120 Ton Capacity (Make :-BLUE STAR, Model No. LCWR 1-120 at MTP storages AC Plant complete with cooling tower, AHU & other accessories in 3 shifts as per timings decided by Engineer in charge for efficient and continuous running / operation of central AC Plant and its electrical panel board with other installation / equipments as mentioned below:- \n(a) Water cooled package chiller unit model LCWR 1-120 - 03 Nos\n(b) Chiller water pump motor model ND-160 M capacity 15 HP,Make- Crompton Greaves - 03 Nos\n(c) Chiller water pump set Model BWC 80/100 capacity 360 USGPM at 30 Mtr head,Make-Beacon Weir -03 Nos\n(d) Condenser water pump set Model BWC 80/100 capacity 450 USGPM at 25 Mtr head,Make-Beacon Weir-03 Nos\n(e) Condenser water pump motor Model ND-160 L capacity 15 HP,Make- Crompton Greaves - 03 Nos\n(f) Air handling unit model ESHW4-350 of capacity 36396 cmh with blower motor, cooling coil, heater bank, humidity and temperature controller, electric panel complete-04 Nos. Make- Blue Star\n(g) FRP Cooling tower capacity 450 USGPM, Model AQ 3870 with CT fan-03 Nos Make- Paharpur\n(h) Electrical control panel cubical type floor mounted with maint switch MCBs volmeter, Ammeter, Starter Condenser etc. complete-01 set\n(j) Control devices such as expansive valve thermostat solenoid valve HP/LP/CP cut outs with panel board installed gauges-01 set.\n(k) Digit type thermometer - 01 set\n(l)Air supply duct with grill diffusers, dampers and heater etc complete - 04 sets\n(m) Condenser piping MS 100/80/50 mm dia with valves pressure gauge, temperature gauge complete -01 set.\n
3 1.02 8. Maintenance & operation of cold room of capacity 9 TR & cool room capacity 4 TR running round the clock at Base Victualling Yard karwar in two shift including Sunday and Holiday including taking care from any pilferage, theft or damage, cleaning etc complete for the following all as directed:-\n(a) Air cooled split type chiller refrigeration unit each capacity 4 TR (Working 01 Nos and 01 No stand ) scroll hermatic compressor capacity Model No MT -50 of make Maneorope based non CFC 134 A refrigerent inside room temperature 4º C To 8ºC .\n(b) Air cooled split type chiller refrigeration unit each capacity 9TR (Working 01Nos. and 01 No Stand) or scroll hermatically compressor Model No MT 4 CC - 6.2 Y (BITZER) with non CFC R404 a refrigerent inside room temperature -15ºC to -23ºC \n9. Maintenance & operation of cold room of capacity 4 TR & cool room capacity 4 TR running round the clock located at INHS Patanjali Hospital karwar in two shift including Sunday and Holiday including taking care from any pilferage, theft or damage, cleaning etc complete for the following all as directed:-\n(a) Air cooled split type chiller refrigeration unit each capacity 4 TR (Working 02 Nos) scroll hermatic compressor capacity of make Maneorope based non CFC 134 A refrigerent inside room temperature 4º C To 8ºC.\n(b) Air cooled split type chiller refrigeration unit each capacity 4TR (Working 02Nos) scroll hermatically compressor Model No MT 4 CC - 6.2 Y (BITZER) with non CFC R404 A refrigerent inside room temperature -15ºC to -23ºC \nNote for item No.1-6 above\n(a) Contractor has to employ following staff for manning & operation of the AC plants at each shifts of 8 hours \n(i) One No operator having minimum ITI qualification in Ref Mech/Electrician trade from Govt recognised institute with minimum 2 years’ experience in maintenance & operation of AC plants in each shift of 8 hrs (Total 3 shifts )( for item No. 1 to 6)\n(ii) One No operator having minimum ITI qualification in Ref Mech/Electrician trade from Govt recognised institute with minimum 2 years’ experience in maintenance & operation of AC plants in each shift of 8 hrs .(Total 2 shifts)(for item No.7 & 8)\n(b) Contractor will maintain proper records of all kinds of daily, weekly , monthly, quarterly, half yearly, yearly or whatsoever maintenance is carried out during contract period in a binded book/register and will obtain the signature of Engineer-in-Charge\n(c) The operator/helper will ensure general cleanliness and upkeep of the installation on daily basis.\n
4 1.03 Terms & conditions \n1. Rates quoted will deemed to have included all taxes like GST as applicable and no separate cost wise be paid on account of same. \n2. Unserviceable dismantled materials will be the property of the department.\n3. You will liable for completion of job works within 20 days of placing Job Order. \n4. 100% payment will be made on completion of job work against your bill.\n5. Job Order can be closed in short notice (i.e 24 hours in advance) on Acceptance of Tender and the payment will be made till the date of acceptance of tender.\n
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,