Food Corporation Of India-FCI has published Tender For Replacement Of Asbestos Sheet Roofing By Profile Sheet Replacement Of Asbestos Sheet Roofing By Profile Sheet Roofing In Mrm ( 2500Mt ) Shed , Mini Sheds ( 1280Mt ) At Fci Fsd Hojai. Submission Date for this Tender is 02-03-2020. Shed Construction Tenders in FCI FSD HOJAI Assam. Bidders can get complete Tender details and download the document.
Name of Work: Replacement of Asbestos sheet roofing by profile sheet roofing in MRM (2500MT)shed,mini sheds (1280MT)at FCI FSD Hojai | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos Cement Sheet. | BI01010001010000000000000515BI0100001113 | 2800 | sqm |
2 | 2 | Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. | BI01010001010000000000000515BI0100001114 | 765 | kg |
3 | 3 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12.00 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses. | BI01010001010000000000000515BI0100001115 | 2746.5 | sqm |
4 | 4 | Providing and fixing precoated galvanised steel sheet roofingaccessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) | BI01010001010000000000000515BI0100001116 | 180 | metre |
5 | 5 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase. | BI01010001010000000000000515BI0100001117 | 270 | metre |
6 | 6 | Supply , installation, testing & commissioning of turbo ventilators size 22” in stainless steel 430 grade with approximate weight 4.85kg having a CFM-7km per hour, 2440 with blade length 369mm, wings of 80mm ,f outer wings =22”-24 nos., inner wings =22”-6 nos.,with self lubricating ball bearings etc.as per manufacturers specificationand stainless steel base plate including cutting of existing precoated roofing sheet as per the direction of Enginner-In-Charge | BI01010001010000000000000515BI0100001118 | 12 | each |
7 | 7 | Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand & manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand. | BI01010001010000000000000515BI0100001119 | 760 | metre |
8 | 8 | Credit for old dismantled MATERIAL on as is where is basis including taking away form godown/ DEPOT premises. | BI01010001010000000000000515BI0100001124 | ||
9 | 8.01 | Asbestos roofing sheets | BI01010001010000000000000515BI0100001125 | 2800 | sqm |
10 | 8.02 | G.I. J/H hooks | BI01010001010000000000000515BI0100001126 | 680 | kg |
11 | 9 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. | BI01010001010000000000000515BI0100001127 | 42 | sqm |
12 | 10 | Repairing and greasing of rolling shutter including tightening /replacement of spring wherever required including replacement of damaged strips andside koni complete,repair of shutter as per the direction of Engineer -in-charge(this excludes the cost of spring and strips but including the cost of side koni) | BI01010001010000000000000515BI0100001128 | 27 | each |
13 | 11 | Reparing of roof godown with profing material such as tar felt/flash strip etc.with bitumastic adhesive including replacement of bitumen washer and tightening of "J" hook & nuts complete as per the direction of Engineer-in-charge . | BI01010001010000000000000515BI0100001129 | 2.4 | 5000 MT Godown |
14 | 12 | Reparing of cement concrete flooring up to 50mm thick patches of area up to 2.0 sqm .and under ,including cutting the patch in proper shape including cleaning the surface and disposal of malba /rubbish to the dumping ground with all leads including refilling the sunken portion with fresh material such as jamuna sand and cement concrete 1:5:10(1 cement:5 fine sand:10 graded stone aggregate 40 mm size) wherever required. | BI01010001010000000000000515BI0100001130 | 60 | sqm |
15 | 13 | Supplying of spring for rollling shutter 27.5 cm long manufactured from high tensile steel wire of required strength as per direction of Engineer -in- charge . | BI01010001010000000000000515BI0100001131 | 20 | each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy