Construction And Renovation Works Of Purbanchal College , Dhemaji, Purbanchal College, Silapather, Dhemaji, Assam-Assam

Assam State Housing Board has published Construction And Renovation Works Of Purbanchal College , Dhemaji. Submission Date for this Tender is 02-03-2020. Building Work Tenders in Purbanchal College, Silapather, Dhemaji, Assam Assam. Bidders can get complete Tender details and download the document.




Tender Notice

23748522
Construction And Renovation Works Of Purbanchal College , Dhemaji
Open Tender
Indian
Assam
Purbanchal College, Silapather, Dhemaji, Assam
02-03-2020

Tender Details

Construction And Renovation Works Of Purbanchal College , Dhemaji

Key Value

Document Fees
INR 5000 /-
EMD
INR 220000.0 /-
Tender Value
INR 1.10 Crore /-

BOQ Items

Name of Work: Construction and Renovation works of Purbanchal College, Dhemaji
Sl. No. Item Description Item Code / Make Quantity Units
1 1 1.Name of Scheme:Construction of Compuer Center at Purbanchal College, Silapathar, District Dhemaji, Assam under new construction schemes of RUSA for the year 2018-2019 . Anx-A_1
2 2 GROUND FLOOR Anx-A_2
3 3 Earth work in excavation for foundation trenches of walls, retain -ing walls, footings of columns, steps, septic tanks etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. Anx-A_3
4 4 I) Upto a depth of 2m below the existing ground level . Anx-A_4
5 5 a) In ordinary soil Anx-A_5 101.88 CU.M.
6 6 Earth/Sand filling in plinth in layers not more than 150 mm thk. including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensati -on, Forest Roalty, Sales Tax and other duties and taxes as may be necessary Anx-A_6
7 7 I) With silt (Predominantly non plastic ) by truck carriage including loading and unloading . Anx-A_7 109.29 CU.M.
8 8 Plain Cement Concrete works. Anx-A_8
9 9 Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, steps, walls, brick work etc. as directed and specifoed including dewatering if necessary and curing complete (shuttering where necessary shall be be measured and paid separately) Anx-A_9
10 10 a) In Prop. 1 cement : 3 Sand : 6 Coarse agg. by volume Anx-A_10 4.25 CU.M.
11 11 Providing and laying plain/reinforced cement concrete work with coarse sand & 20 mm down graded stone aggregate including dewatering if necessary and curing complete supply of materials but excluding cost of form work and reinfircement for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately ) Anx-A_11
12 12 (I) Using mixture machine Anx-A_12
13 13 (A ) In sub-structure upto plinth level. Anx-A_13
14 14 I) Foundations, footings, columns with base tie and plinth beam, grade beam ,pile cap ,base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not less than 100mm thick upto plinth level. Anx-A_14
15 15 N) Without using admixture, plasticiser Anx-A_15
16 16 b) M 20 grade concrete or Prop 1:1.5:3 Anx-A_16 26.88 CU.M.
17 17 B ) In super structure from plinth level up to 1st floor level.. Anx-A_17
18 18 ii ) Columns, pillars, posts, struts, suspanded floor, roof, landing, shelf and support, balcony, lintel,sill band , beam, girder, cantilever,staircase (except spiral staircase and landing) including preparing of top surface and finishing of nosing. Anx-A_18
19 19 N) Without using admixture, plasticiser Anx-A_19
20 20 b) M 20 grade concrete or Prop 1:1.5:3 Anx-A_20 41.34 CU.M.
21 21 N) Without using admixture, plasticiser Anx-A_21
22 22 Providing and laying 25 mm thick damp proof course with cement concrete in prop. 1:1.5:4 with graded stone aggregate of 10mm down nominal size including providing approved damp proff mixture in prop. as recomended by the manufacturer including curing etc. complete as directed. Anx-A_22 8.94 SQ.M.
23 23 BRICK WORK Anx-A_23
24 24 Providing brick soling in foundation and under floor with stone/ best quality picked jhama bricks, sand packed and laid to level and in panels after preparing the surface as directed including all labour and materials and if necessary dewatering complete . Anx-A_24
25 25 a) Brick on flat soling Anx-A_25 237.96 SQ.M.
26 26 Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub structure upto plinth level. Anx-A_26
27 27 (I) In Sub-structure upto plinth level including dewatering if necessary Anx-A_27
28 28 b) In proportion 1:4 Anx-A_28 19.4 CU.M.
29 29 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in in super structure above plinth upto first floor level (protruding M.S. rod / Tor steel of column to be embeded in cement morter and will be measured and paid separately) Anx-A_29
30 30 (A) 112 mm thick brick wall Anx-A_30
31 31 a) In cement morter in proportion 1:4( 1 cement :4 sand) Anx-A_31 118.32 SQ.M.
32 32 SHUTTERING AND FORM WORK Anx-A_32
33 33 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for insitu reinforced cement concrete and plain concrete work in Anx-A_33
34 34 Foundation, footing, base of columns, pile cap, raft and mass concrtete works etc. Anx-A_34
35 35 a) Using 38 mm thick plank Anx-A_35 37.8 SQ.M.
36 36 Sides of tie beams, plinth beams, grade beams etc.at or below ground level Anx-A_36
37 37 (a)) Using 38 mm thick plank Anx-A_37 81.44 SQ.M.
38 38 Columns, pillars ,posts & strut Anx-A_38
39 39 a) Square, Rectangular, polygonal in plan or any shape like Tee/ L etc having plane vertical face. Anx-A_39
40 40 I) Using 38 mm thick plank Anx-A_40 52.92 SQ.M.
41 41 Sides and soffits of beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties Anx-A_41
42 42 a) For depth not exceeding 1.0M Anx-A_42
43 43 I) Using 38 mm thick plank Anx-A_43 64.22 SQ.M.
44 44 iii) Flat surface such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas balconies and the like. Anx-A_44
45 45 a) Floors etc. upto 200 mm in thickness Anx-A_45
46 46 I) Using 38 mm thick plank Anx-A_46 176.4 SQ.M.
47 47 Staircase with sloping or stepped soffits including risers and stringers but excluding landing.(using 38mm thick plank) Anx-A_47 19.53 SQ.M.
48 48 Vertical ties, fins, sun breaker, louvers, band, dropwalls etc. Anx-A_48
49 49 I) Using 38 mm thick plank Anx-A_49 2.5 SQ.M.
50 50 Providing form work of 12 mm thick plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in -situ reinforced concrete works upto 1st floor level. Anx-A_50
51 51 a) Thickness not exceeding 200mm Anx-A_51 7.42 SQ.M.
52 52 PLASETRING AND POINTING Anx-A_52
53 53 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. Anx-A_53
54 54 A) On rough side Anx-A_54
55 55 b) In cement mortar 1:4 Anx-A_55 118.32 SQ.M.
56 56 B) On fair side Anx-A_56
57 57 b) In cement mortar 1:4 Anx-A_57 419.28 SQ.M.
58 58 Extra for plastering on ceiling and soffits of stair up to 1st floor level including curing complete as directed. Anx-A_58
59 59 I) Ground floor Anx-A_59 248.04 SQ.M.
60 60 FLOORING : Anx-A_60
61 61 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. Anx-A_61 145.73 SQ.M.
62 62 Cement plaster skirting with cement mortar ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement including rounding of juctions with floor. Anx-A_62
63 63 b) 20 mm thick . Anx-A_63 19.78 SQ.M.
64 64 Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Anx-A_64
65 65 (2) 600mm x 900mm and above Anx-A_65 18.99 SQ.M.
66 66 Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete. Anx-A_66
67 67 (2) 600mm x 900mm and above Anx-A_67 10.44 SQ.M.
68 68 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) Anx-A_68
69 69 a) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make Anx-A_69
70 70 ii) Of size 600mmx600mm and above Anx-A_70 91.46 SQ.M.
71 71 WOOD WORK Anx-A_71
72 72 Providing wood work in frames (chowkat) of doors, windows, clearstory windows and other similar works wrought, framed and fixed in position in contact with C.C. or brick masonry walls including supplying, fitting and fixing with nails, screws, bolts and nuts complete with M.S. plate hold fasts (4mm X 3mm X 250mm) as per design and embeded in cement concrete block in prop. 1:1:4 and with 2 coats of kiricide oiling to the timber faces in contact with C.C. and masonry as directed and specified. Anx-A_72
73 73 a) With sal wood Anx-A_73 0.16 CUM
74 74 Providing and fixing flush door shutters solid core construction with frame of first class hard wood with cross bend and face veneered plywood face panels conforming to relevant I.S. Code including oxidised iron butt hinges (100X75X3.5mm) 6 nos. with necessary wood screws. Anx-A_74
75 75 a) Decorative type face panel and block board core . Anx-A_75
76 76 I) 40 mm thick Anx-A_76 5.04 SQ.M.
77 77 Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand (HINDALCO/NALCO/BALCO/JINDAL/OTHER equivalent primary producer ) without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. Anx-A_77
78 78 a) 3 track sliding window . Anx-A_78
79 79 ii) 5 mm frosted glass Anx-A_79 16.2 SQ.M.
80 80 STEEL AND IRON WORK Anx-A_80
81 81 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) Anx-A_81
82 82 a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL Anx-A_82
83 83 (ii)Super Ductile (SD) TMT reinforcement bars Anx-A_83 93.72 QNTL
84 84 Providing, fitting and fixing M.S. Grill of required pattern for winddows / clearstory windows / openings with M.S. flats at required spacing and farmed alround square or round M.S. bars with round headed bolts and nuts or screws. Anx-A_84
85 85 a) Ornamental Grill Anx-A_85
86 86 c) Fixed to brickwork/ P.C.C/R.C.C. Anx-A_86 194.4 Kg
87 87 Applying primary coat over new steel and other metal surfaces upto 100 mm in width or grith after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes fine steel wood scrappers and sand paper. Anx-A_87
88 88 a) With ready mixed red lead red oxide primer Anx-A_88 40.5 SQ.M.
89 89 Painting two coats ( excluding priming coat ) on new steel and other metal surfaces with enamel paint of approved brand and manufacture( Asian paint/Berger paint/ICI paint/ J &Npaint/Nerolac to give an even shade including cleaning the surface of all dirt, dust and other foreign matter . Anx-A_89
90 90 (I) Surfaces over 100 mm in width or girth Anx-A_90
91 91 b) High gloss ( Asian paint/ Berger paint/ ICI paint / J& N paint / Nerolac) Anx-A_91 40.5 SQ.M.
92 92 Applying priming coat over new wood based surfaces over 10 cm in width/grith after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. Anx-A_92
93 93 a) With ready mixed paint, wood primer ( white). Anx-A_93 12.6 SQ.M.
94 94 Painting two coats ( excluding priming coat ) on new wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of ditrt, dust and other foreign material , sand papering and stopping Anx-A_94
95 95 (I) Surfaces over 100 mm in width or girth Anx-A_95
96 96 a) High gloss (Asian Paint/ Berger Paint /ICI paint/ J& N paint /Nerolac Anx-A_96 12.6 SQ.M.
97 97 Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/ Berger/Dulux (ICI)/ Nerolac over concrete/cement plaster/ brick walls ( internal )and after removing all the loosely adhering material from the wall/ceiling surface with the help of emerey stone ,putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. Anx-A_97 508.97 SQ.M.
98 98 c) Applying one coat of distemper primer of approved brand and manufacture on wall surfaces after thoroughly brushing the surface free from mortar drops and other foreign matter and including preparing the surface even and sand papered smooth. Anx-A_98 508.97 SQ.M.
99 99 Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. Anx-A_99
100 100 (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) Anx-A_100 508.97 SQ.M.
101 101 a) Providing one coat of cement primer( on ext. wall) of approved brand and manufacture on new surfaces after thoroughly brooming the surface preparing the surface even and sand papered smooth. Anx-A_101 146.95 SQ.M.
102 102 Finishing old /new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish , finish of Sandex Matt brand of Snowcem India Ltd. Of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels ( two coats) Anx-A_102 146.95 SQ.M.
103 103 MISCELLANEOUS Anx-A_103
104 104 Pre construction antitermite treatment at the bottom of foundation of foundation pits and walls on either side up to a height of 300m.m. from bottom of the excavation made for column ,plinth beam, wall trenches etc. by applying the emulsion @ 5 litres per sq.mt. Of the surface area before starting construction work( supplying of necesary tools and accessories by the contractor) as per the direction of the Department complete. Anx-A_104
105 105 a)with aquous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water ,I,e, 1% solution. Anx-A_105 145.73 SQ.M.
106 106 Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. Anx-A_106 29.66 SQ.M.
107 107 Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. Anx-A_107
108 108 ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. Anx-A_108 49.44 RM
109 109 Supplying, fitting and fixing alluminum fittings of approved make reasonably smooth, free from sharp edges, flows and other defacts with counter sunk holes for screws including necessary aluminium screws etc. complete ( annodised to a bright natural mat or stain finish). Anx-A_109
110 110 I) 300 X 16 mm Anx-A_110 2 Each
111 111 b) Tower bolt Anx-A_111
112 112 I) 300 X 12 mm Anx-A_112 2 Each
113 113 ii) 250 X 12 mm Anx-A_113 7 Each
114 114 c) Door handle Anx-A_114
115 115 I) 150 mm Anx-A_115 7 Each
116 116 I) 100 mm Anx-A_116 7 Each
117 117 e) Butt hinge v ) 100 mm x75mmx 4mm Anx-A_117 14 Pair
118 118 FIRST FLOOR Anx-A_118
119 119 Providing and laying plain/reinforced cement concrete work with coarse sand & 20 mm down graded stone aggregate including dewatering if necessary and curing complete supply of materials but excluding cost of form work and reinfircement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately ) Anx-A_119
120 120 (I) Using mixture machine Anx-A_120
121 121 ii ) Columns, pillars, posts, struts, suspanded floor, roof, landing, shelf and support, balcony, lintel,sill band , beam, girder, cantilever,staircase (except spiral staircase and landing) including preparing of top surface and finishing of nosing. Anx-A_121
122 122 N) Without using admixture, plasticiser Anx-A_122
123 123 b) M 20 grade concrete or Prop 1:1.5:3 Anx-A_123 39.16 CU.M.
124 124 Extra over item Nos.2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level. Anx-A_124 39.16 CU.M.
125 125 BRICK WORK Anx-A_125
126 126 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in in super structure above plinth upto first floor level (protruding M.S. rod / Tor steel of column to be embeded in cement morter and will be measured and paid separately) Anx-A_126
127 127 (A) 112 mm thick brick wall Anx-A_127
128 128 a) In cement morter in proportion 1:4( 1 cement :4 sand) Anx-A_128 203.74 SQ.M.
129 129 Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. Anx-A_129 203.74 SQ.M.
130 130 SHUTTERING AND FORM WORK Anx-A_130
131 131 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for insitu reinforced cement concrete and plain concrete work in Anx-A_131
132 132 Columns, Pillars , Posts & Strut Anx-A_132
133 133 a) Square, Rectangular, polygonal in plan or any shape like Tee/ L etc having plane vertical face. Anx-A_133
134 134 I) Using 38 mm thick plank Anx-A_134 47.88 SQ.M.
135 135 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.2.1 & 3.2.3(b). Anx-A_135 47.88 SQ.M.
136 136 Sides and soffits of beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties Anx-A_136
137 137 a) For depth not exceeding 1.0M Anx-A_137
138 138 I) Using 38 mm thick plank Anx-A_138 68.1 SQ.M.
139 139 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.2.1 & 3.2.3(b). Anx-A_139 68.1 SQ.M.
140 140 iii) Flat surface such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas balconies and the like. Anx-A_140
141 141 a) Floors etc. upto 200 mm in thickness Anx-A_141
142 142 I) Using 38 mm thick plank Anx-A_142 176.4 SQ.M.
143 143 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.2.1 & 3.2.3(b). Anx-A_143 176.4 SQ.M.
144 144 Providing form work of 12 mm thick plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in -situ reinforced concrete works upto 1st floor level. Anx-A_144
145 145 a) Thickness not exceeding 200mm Anx-A_145 7.42 SQ.M.
146 146 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.2.1 & 3.2.3(b). Anx-A_146 7.42 SQ.M.
147 147 PLASETRING AND POINTING Anx-A_147
148 148 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. Anx-A_148
149 149 A) On rough side Anx-A_149
150 150 b) In cement mortar 1:4 Anx-A_150 203.74 SQ.M.
151 151 Extra over item on 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every addl floor or part there of including curing complete as directed. Anx-A_151 203.74 SQ.M.
152 152 (a) On Single coat plaster Anx-A_152
153 153 B) On fair side Anx-A_153
154 154 b) In cement mortar 1:4 Anx-A_154 611.84 SQ.M.
155 155 Extra over item on 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every addl floor or part there of including curing complete as directed. Anx-A_155
156 156 (a) On Single coat plaster Anx-A_156 611.84 SQ.M.
157 157 Extra for plastering on celling and soffits of stair up to 1st floor level (instead of plastering on walls) including curing complete as directed. Anx-A_157 360.22 SQ.M.
158 158 FLOORING, PAVING AND ROOFING : Anx-A_158
159 159 40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed. Anx-A_159 145.73 SQ.M.
160 160 Cement plaster skirting with cement mortar ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement including rounding of juctions with floor. Anx-A_160
161 161 b) 20 mm thick . Anx-A_161 19.78 SQ.M.
162 162 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) Anx-A_162
163 163 a) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make Anx-A_163
164 164 ii) Of size 600mmx600mm and above Anx-A_164 148.88 SQ.M.
165 165 WOOD WORK Anx-A_165
166 166 Providing wood work in frames (chowkat) of doors, windows, clearstory windows and other similar works wrought, framed and fixed in position in contact with C.C. or brick masonry walls including supplying, fitting and fixing with nails, screws, bolts and nuts complete with M.S. plate hold fasts (4mm X 3mm X 250mm) as per design and embeded in cement concrete block in prop. 1:1:4 and with 2 coats of kiricide oiling to the timber faces in contact with C.C. and masonry as directed and specified. Anx-A_166
167 167 a) With sal wood Anx-A_167 0.16 CUM
168 168 Providing and fixing flush door shutters solid core construction with frame of first class hard wood with cross bend and face veneered plywood face panels conforming to relevant I.S. Code including oxidised iron butt hinges (100X75X3.5mm) 6 nos. with necessary wood screws. Anx-A_168
169 169 a) Decorative type face panel and block board core . Anx-A_169
170 170 I) 40 mm thick Anx-A_170 5.04 SQ.M.
171 171 STEEL AND IRON WORK Anx-A_171
172 172 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for RCC work / RB walling including straightening, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete ( upto first floor level ). Anx-A_172
173 173 a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL Anx-A_173
174 174 (ii)Super Ductile (SD) TMT reinforcement bars Anx-A_174 53.8 QNTL
175 175 Extra over item 18.1.1(a,b,c) for each subequent floor or part thereof above first floor level. Anx-A_175 53.8 QNTL
176 176 Providing, fitting and fixing M.S. Grill of required pattern for winddows / clearstory windows / openings with M.S. flats at required spacing and farmed alround square or round M.S. bars with round headed bolts and nuts or screws. Anx-A_176
177 177 II) Ornamental Grill Anx-A_177
178 178 C) Fixed to brickwork /P.C.C./R.C.C. Anx-A_178 402.03 Kg
179 179 Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand (HINDALCO/NALCO/BALCO/JINDAL/OTHER equivalent primary producer ) without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. Anx-A_179
180 180 a) 3 track sliding window . Anx-A_180
181 181 ii) 5 mm frosted glass Anx-A_181 19.44 SQ.M.
182 182 Applying primary coat over new steel and other metal surfaces upto 100 mm in width or grith after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes fine steel wood scrappers and sand paper. Anx-A_182 147.04 SQ.M.
183 183 a) With ready mixed red lead red oxide primer Anx-A_183
184 184 Painting two coats ( excluding priming coat ) on new steel and other metal surfaces with enamel paint of approved brand and manufacture( Asian paint/Berger paint/ICI paint/ J &Npaint/Nerolac to give an even shade including cleaning the surface of all dirt, dust and other foreign matter . Anx-A_184
185 185 (I) Surfaces over 100 mm in width or girth Anx-A_185 147.04 SQ.M.
186 186 b) High gloss ( Asian paint/ Berger paint/ ICI paint / J& N paint / Nerolac) Anx-A_186
187 187 Applying priming coat over new wood based surfaces over 10 cm in width/grith after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. Anx-A_187
188 188 a) With ready mixed paint, wood primer ( white). Anx-A_188 12.6 SQ.M.
189 189 Painting two coats ( excluding priming coat ) on new wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of ditrt, dust and other foreign material , sand papering and stopping Anx-A_189
190 190 (I) Surfaces over 100 mm in width or girth Anx-A_190
191 191 b) High gloss (Asian Paint/ Berger Paint /ICI paint/Nerolac Anx-A_191 12.6 SQ.M.
192 192 Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/ Berger/Dulux (ICI)/ Nerolac over concrete/cement plaster/ brick walls ( internal )and after removing all the loosely adhering material from the wall/ceiling surface with the help of emerey stone ,putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. Anx-A_192 623.99 SQ.M.
193 193 Applying one coat of distemper primer of approved brand and manufacture on wall surfaces after thoroughly brushing the surface free from mortar drops and other foreign matter and including preparing the surface even and sand papered smooth. Anx-A_193 623.99 SQ.M.
194 194 Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. Anx-A_194
195 195 (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) Anx-A_195 623.99 SQ.M.
196 196 Providing one coat of cement primer( on ext. wall) of approved brand and manufacture on new surfaces after thoroughly brooming the surface preparing the surface even and sand papered smooth. Anx-A_196 143.71 SQ.M.
197 197 Finishing old /new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish , finish of Sandex Matt brand of Snowcem India Ltd. Of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels ( two coats) Anx-A_197 143.71 SQ.M.
198 198 HARDWARE FITTINGS Anx-A_198
199 199 Supplying, fitting and fixing anodised alluminium fittings of approved make reasonably smooth, free from sharp edges, flows and necessary aluminium screws etc. complete ( annodised to a bright natural mat or stain finish ). Anx-A_199
200 200 a) Sliding door bolts Anx-A_200
201 201 I) 300 X 16 mm Anx-A_201 2 EACH
202 202 b) Tower bolt Anx-A_202
203 203 I) 300 X 12 mm Anx-A_203 2 EACH
204 204 ii) 150 X 10 mm Anx-A_204 2 EACH
205 205 c) Door handle Anx-A_205
206 206 I) 150 mm Anx-A_206 2 EACH
207 207 ii) 100 mm Anx-A_207 2 EACH
208 208 e) Butt hinge v) 100 mm x75mmx 4mm Anx-A_208 8 pair
209 209 WATER SUPPLY & SANITARY WORK Anx-A_209
210 210 Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. Anx-A_210
211 211 a) In exposed surfaces or in trenches. Anx-A_211
212 212 (ii) 110mm dia Anx-A_212 52.2 R.M.
213 213 Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. Anx-A_213
214 214 a) In exposed surfaces or in trenches Anx-A_214
215 215 ii) 110 mm dia. Anx-A_215 10 Each
216 216 Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. Anx-A_216
217 217 a) In exposed surfaces or in trenches Anx-A_217
218 218 ii) 110 mm dia. Anx-A_218 10 Each
219 219 Supplying fiting and fixing PVC plain single tee of (Supreme /Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. Anx-A_219
220 220 a) In exposed surfaces or in trenches Anx-A_220
221 221 ii) 110 mm dia. Anx-A_221 5 Each
222 222 Providing fitting and fixing 100 mm dia PVC Cowel with ISI make complete as directed and specified. Anx-A_222 5 Each
223 223 Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Anx-A_223
224 224 b)Medium point upto 6.00mtr length Anx-A_224 19 Per point
225 225 c)Long point upto 10.00mtr length Anx-A_225 18 Per point
226 226 Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Anx-A_226
227 227 b)Medium point upto 6.00mtr length Anx-A_227 12 Per point
228 228 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\n Anx-A_228
229 229 Extra long point up to 25.00 metre. Length. Anx-A_229 16 per point
230 230 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. Anx-A_230
231 231 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. Anx-A_231 77 per mtr
232 232 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. Anx-A_232 70 per mtr
233 233 With 2 x 16 sq. mm. + earth continuity with 1x10 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. Anx-A_233 52 per mtr
234 234 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Anx-A_234
235 235 12 way SPN double door Anx-A_235 2 EACH
236 236 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Anx-A_236
237 237 6 way TPN (4+18) double door Anx-A_237 2 EACH
238 238 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. Anx-A_238
239 239 B Series\n(Schneider MG, legrand, Hager make) Anx-A_239
240 240 6 to 32A Anx-A_240 20 EACH
241 241 Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. Anx-A_241
242 242 B Series\n(Schneider MG, legrand, Hager make) Anx-A_242
243 243 63A Anx-A_243 2 EACH
244 244 Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. Anx-A_244
245 245 C Series (ABB, Schneider MG, legrand, Hager make) Anx-A_245
246 246 100A Anx-A_246 1 EACH
247 247 MCCB with Thermal & Magnetic Release Anx-A_247
248 248 Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. Anx-A_248
249 249 25 KA 415V 50 Hz 3P MCCB \n(Schneider, legrand, Siemens make) Anx-A_249
250 250 16A Anx-A_250 2 EACH
251 251 63A Anx-A_251 2 EACH
252 252 Supplying including fitting and fixing of high speed AC Ceiling fan complete with all accessories like , down rod, canopy etc.of following sweeps with making necessary connection etc.as reqd complete and directed by the deptt.(Without regulator) Anx-A_252
253 253 a) 1400mm sweep Anx-A_253 16 each
254 254 Installation ,testing and commissioning of ceiling fan including the regulator, down rod of standard size(up to 300mm length) and connection etc complete as specified and directed by the department. Anx-A_254 16 each
255 255 Supplying and fixing Call bell(Buzer) including 5 Amps capacity flush type bell push switch including connections as approved by the Deptt as required . Anx-A_255 4 each
256 256 Supplying fitting and fixing of single wall brackets model 37712 (or equivalent as approved by the Deptt.) on the wall in GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover with all accessories including connection as required complete. Without lamp. Anx-A_256 6 each
257 257 Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. Anx-A_257
258 258 Striplite luminaries complete with VPIT copper ballast/ Electronic ballast and decorative end cap and 1 X 36 / 40 watt Fluorescent tube.(Crompton Greaves make) Model- DSG1114LDB CROMGOLD / DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD / DSG 1414EB PLANET GOLD with Super Saver / Super Brite Lamp. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make. Anx-A_258 16 each
259 259 WVF 53414 SGW 4 x 14 W FTL T5) Recess mounted indirect- direct luminaries with High Efficiency Translucence (HET) Technology suitable for FTL T5) Lamps. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ JAQUAR make). Anx-A_259 2 each
260 260 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . Anx-A_260
261 261 185.00 Sq.mm 4 Core U.G. cable in 80 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) Anx-A_261 10 mtr
262 262 Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . Anx-A_262 2 each
263 263 Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. Anx-A_263 2 each
264 264 Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. Anx-A_264 3 mtr
265 265 Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. Anx-A_265 3 mtr
266 266 Supplying & laying of 25x4 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt. Anx-A_266 3 per mtr
267 267 Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt. Anx-A_267 1 Each
268 268 Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt. Anx-A_268 6 Each
269 269 Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG1.66mm) thick CR sheet and 35 mm × 35 mm × 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items. Anx-A_269
270 270 1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no Anx-A_270
271 271 2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos. Anx-A_271
272 272 3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set Anx-A_272
273 273 4. 40 Amp 4 pole ON-OFF poser contactor - 1 No. Anx-A_273
274 274 5. Surface mounting timer switch - 1 No. Anx-A_274
275 275 6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos Anx-A_275
276 276 7. 0-40 Amp electro-mechanical counter display 3 Phase 4 wire electronic hybrid energy meter Anx-A_276 1 Each
277 277 2. Name of Scheme: Construction of Class rooms at Purbanchal College , Silapathar, District Dhemaji , Assam under new construction schemes of RUSA for the year 2018-2019 . Anx-A_277
278 278 GROUND FLOOR Anx-A_278
279 279 Earth work in excavation for foundation trenches of walls, retain -ing walls, footings of columns, steps, septic tanks etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. Anx-A_279
280 280 I) Upto a depth of 2m below the existing ground level . Anx-A_280
281 281 a) In ordinary soil Anx-A_281 124.51 CU.M.
282 282 Earth/Sand filling in plinth in layers not more than 150 mm thk. including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensati -on, Forest Roalty, Sales Tax and other duties and taxes as may be necessary Anx-A_282
283 283 I) With silt (Predominantly non plastic ) by truck carriage including loading and unloading . Anx-A_283 106.31 CU.M.
284 284 Plain Cement Concrete works. Anx-A_284
285 285 Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, steps, walls, brick work etc. as directed and specifoed including dewatering if necessary and curing complete (shuttering where necessary shall be be measured and paid separately) Anx-A_285
286 286 a) In Prop. 1 cement : 3 Sand : 6 Coarse agg. by volume Anx-A_286 5.19 CU.M.
287 287 Providing and laying plain/reinforced cement concrete work with coarse sand & 20 mm down graded stone aggregate including dewatering if necessary and curing complete supply of materials but excluding cost of form work and reinfircement for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately ) Anx-A_287
288 288 (I) Using mixture machine Anx-A_288
289 289 (A ) In sub-structure upto plinth level. Anx-A_289
290 290 I) Foundations, footings, columns with base tie and plinth beam, grade beam ,pile cap ,base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not less than 100mm thick upto plinth level. Anx-A_290
291 291 N) Without using admixture, plasticiser Anx-A_291
292 292 b) M 20 grade concrete or Prop 1:1.5:3 Anx-A_292 31.27 CU.M.
293 293 B ) In super structure from plinth level up to 1st floor level.. Anx-A_293
294 294 ii ) Columns, pillars, posts, struts, suspanded floor, roof, landing, shelf and support, balcony, lintel,sill band , beam, girder, cantilever,staircase (except spiral staircase and landing) including preparing of top surface and finishing of nosing. Anx-A_294
295 295 N) Without using admixture, plasticiser Anx-A_295
296 296 b) M 20 grade concrete or Prop 1:1.5:3 Anx-A_296 37.86 CU.M.
297 297 N) Without using admixture, plasticiser Anx-A_297
298 298 Providing and laying 25 mm thick damp proof course with cement concrete in prop. 1:1.5:4 with graded stone aggregate of 10mm down nominal size including providing approved damp proff mixture in prop. as recomended by the manufacturer including curing etc. complete as directed. Anx-A_298 9.57 SQ.M.
299 299 BRICK WORK Anx-A_299
300 300 Providing brick soling in foundation and under floor with stone/ best quality picked jhama bricks, sand packed and laid to level and in panels after preparing the surface as directed including all labour and materials and if necessary dewatering complete . Anx-A_300
301 301 a) Brick on flat soling Anx-A_301 248.37 SQ.M.
302 302 Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub structure upto plinth level. Anx-A_302
303 303 (I) In Sub-structure upto plinth level including dewatering if necessary Anx-A_303
304 304 b) In proportion 1:4 Anx-A_304 20.3 CU.M.
305 305 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in in super structure above plinth upto first floor level (protruding M.S. rod / Tor steel of column to be embeded in cement morter and will be measured and paid separately) Anx-A_305
306 306 (A) 112 mm thick brick wall Anx-A_306
307 307 a) In cement morter in proportion 1:4( 1 cement :4 sand) Anx-A_307 166.92 SQ.M.
308 308 SHUTTERING AND FORM WORK Anx-A_308
309 309 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for insitu reinforced cement concrete and plain concrete work in Anx-A_309
310 310 Foundation, footing, base of columns, pile cap, raft and mass concrtete works etc. Anx-A_310
311 311 a) Using 38 mm thick plank Anx-A_311 45.9 SQ.M.
312 312 Sides of tie beams, plinth beams, grade beams etc.at or below ground level Anx-A_312
313 313 (a)) Using 38 mm thick plank Anx-A_313 85.6 SQ.M.
314 314 Columns, pillars ,posts & strut Anx-A_314
315 315 a) Square, Rectangular, polygonal in plan or any shape like Tee/ L etc having plane vertical face. Anx-A_315
316 316 I) Using 38 mm thick plank Anx-A_316 64.26 SQ.M.
317 317 Sides and soffits of beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties Anx-A_317
318 318 a) For depth not exceeding 1.0M Anx-A_318
319 319 I) Using 38 mm thick plank Anx-A_319 69.55 SQ.M.
320 320 iii) Flat surface such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas balconies and the like. Anx-A_320
321 321 a) Floors etc. upto 200 mm in thickness Anx-A_321
322 322 I) Using 38 mm thick plank Anx-A_322 167.48 SQ.M.
323 323 Vertical ties, fins, sun breaker, louvers, band, dropwalls etc. Anx-A_323
324 324 I) Using 38 mm thick plank Anx-A_324 2.5 SQ.M.
325 325 Providing form work of 12 mm thick plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in -situ reinforced concrete works upto 1st floor level. Anx-A_325
326 326 a) Thickness not exceeding 200mm Anx-A_326 7.34 SQ.M.
327 327 PLASETRING AND POINTING Anx-A_327
328 328 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. Anx-A_328
329 329 A) On rough side Anx-A_329
330 330 b) In cement mortar 1:4 Anx-A_330 166.92 SQ.M.
331 331 B) On fair side Anx-A_331
332 332 b) In cement mortar 1:4 Anx-A_332 475.55 SQ.M.
333 333 Extra for plastering on ceiling and soffits of stair up to 1st floor level including curing complete as directed. Anx-A_333
334 334 I) Ground floor Anx-A_334 244.37 SQ.M.
335 335 FLOORING : Anx-A_335
336 336 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. Anx-A_336 141.75 SQ.M.
337 337 Cement plaster skirting with cement mortar ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement including rounding of juctions with floor. Anx-A_337
338 338 b) 20 mm thick . Anx-A_338 19.56 SQ.M.
339 339 Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Anx-A_339
340 340 (2) 600mm x 900mm and above Anx-A_340 18.99 SQ.M.
341 341 Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete. Anx-A_341
342 342 (2) 600mm x 900mm and above Anx-A_342 10.44 SQ.M.
343 343 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) Anx-A_343
344 344 a) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make Anx-A_344
345 345 ii) Of size 600mmx600mm and above Anx-A_345 148.88 SQ.M.
346 346 WOOD WORK Anx-A_346
347 347 Providing wood work in frames (chowkat) of doors, windows, clearstory windows and other similar works wrought, framed and fixed in position in contact with C.C. or brick masonry walls including supplying, fitting and fixing with nails, screws, bolts and nuts complete with M.S. plate hold fasts (4mm X 3mm X 250mm) as per design and embeded in cement concrete block in prop. 1:1:4 and with 2 coats of kiricide oiling to the timber faces in contact with C.C. and masonry as directed and specified. Anx-A_347
348 348 a) With sal wood Anx-A_348 0.16 CUM
349 349 Providing and fixing flush door shutters solid core construction with frame of first class hard wood with cross bend and face veneered plywood face panels conforming to relevant I.S. Code including oxidised iron butt hinges (100X75X3.5mm) 6 nos. with necessary wood screws. Anx-A_349
350 350 a) Decorative type face panel and block board core . Anx-A_350
351 351 I) 40 mm thick Anx-A_351 5.04 SQ.M.
352 352 Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand (HINDALCO/NALCO/BALCO/JINDAL/OTHER equivalent primary producer ) without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. Anx-A_352
353 353 a) 3 track sliding window . Anx-A_353
354 354 ii) 5 mm frosted glass Anx-A_354 16.2 SQ.M.
355 355 STEEL AND IRON WORK Anx-A_355
356 356 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) Anx-A_356
357 357 a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL Anx-A_357
358 358 (ii)Super Ductile (SD) TMT reinforcement bars Anx-A_358 81.4 QNTL
359 359 Providing, fitting and fixing M.S. Grill of required pattern for winddows / clearstory windows / openings with M.S. flats at required spacing and farmed alround square or round M.S. bars with round headed bolts and nuts or screws. Anx-A_359
360 360 a) Ornamental Grill Anx-A_360
361 361 c) Fixed to brickwork/ P.C.C/R.C.C. Anx-A_361 194.4 Kg
362 362 Applying primary coat over new steel and other metal surfaces upto 100 mm in width or grith after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes fine steel wood scrappers and sand paper. Anx-A_362
363 363 a) With ready mixed red lead red oxide primer Anx-A_363 40.5 SQ.M.
364 364 Painting two coats ( excluding priming coat ) on new steel and other metal surfaces with enamel paint of approved brand and manufacture( Asian paint/Berger paint/ICI paint/ J &Npaint/Nerolac to give an even shade including cleaning the surface of all dirt, dust and other foreign matter . Anx-A_364
365 365 (I) Surfaces over 100 mm in width or girth Anx-A_365
366 366 b) High gloss ( Asian paint/ Berger paint/ ICI paint / J& N paint / Nerolac) Anx-A_366 40.5 SQ.M.
367 367 Applying priming coat over new wood based surfaces over 10 cm in width/grith after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. Anx-A_367
368 368 a) With ready mixed paint, wood primer ( white). Anx-A_368 12.6 SQ.M.
369 369 Painting two coats ( excluding priming coat ) on new wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of ditrt, dust and other foreign material , sand papering and stopping Anx-A_369
370 370 (I) Surfaces over 100 mm in width or girth Anx-A_370
371 371 a) High gloss (Asian Paint/ Berger Paint /ICI paint/ J& N paint /Nerolac Anx-A_371 12.6 SQ.M.
372 372 Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/ Berger/Dulux (ICI)/ Nerolac over concrete/cement plaster/ brick walls ( internal )and after removing all the loosely adhering material from the wall/ceiling surface with the help of emerey stone ,putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. Anx-A_372 664.22 SQ.M.
373 373 c) Applying one coat of distemper primer of approved brand and manufacture on wall surfaces after thoroughly brushing the surface free from mortar drops and other foreign matter and including preparing the surface even and sand papered smooth. Anx-A_373 664.22 SQ.M.
374 374 Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. Anx-A_374
375 375 (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) Anx-A_375 664.22 SQ.M.
376 376 a) Providing one coat of cement primer( on ext. wall) of approved brand and manufacture on new surfaces after thoroughly brooming the surface preparing the surface even and sand papered smooth. Anx-A_376 145.17 SQ.M.
377 377 Finishing old /new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish , finish of Sandex Matt brand of Snowcem India Ltd. Of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels ( two coats) Anx-A_377 145.17 SQ.M.
378 378 MISCELLANEOUS Anx-A_378
379 379 Pre construction antitermite treatment at the bottom of foundation of foundation pits and walls on either side up to a height of 300m.m. from bottom of the excavation made for column ,plinth beam, wall trenches etc. by applying the emulsion @ 5 litres per sq.mt. Of the surface area before starting construction work( supplying of necesary tools and accessories by the contractor) as per the direction of the Department complete. Anx-A_379
380 380 a)with aquous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water ,I,e, 1% solution. Anx-A_380 141.75 SQ.M.
381 381 Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. Anx-A_381 29.34 SQ.M.
382 382 Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. Anx-A_382
383 383 ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. Anx-A_383 48.9 RM
384 384 Supplying, fitting and fixing alluminum fittings of approved make reasonably smooth, free from sharp edges, flows and other defacts with counter sunk holes for screws including necessary aluminium screws etc. complete ( annodised to a bright natural mat or stain finish). Anx-A_384
385 385 I) 300 X 16 mm Anx-A_385 2 Each
386 386 b) Tower bolt Anx-A_386
387 387 I) 300 X 12 mm Anx-A_387 2 Each
388 388 ii) 250 X 12 mm Anx-A_388 7 Each
389 389 c) Door handle Anx-A_389
390 390 I) 150 mm Anx-A_390 7 Each
391 391 I) 100 mm Anx-A_391 7 Each
392 392 e) Butt hinge v ) 100 mm x75mmx 4mm Anx-A_392 14 Pair
393 393 FIRST FLOOR Anx-A_393
394 394 Providing and laying plain/reinforced cement concrete work with coarse sand & 20 mm down graded stone aggregate including dewatering if necessary and curing complete supply of materials but excluding cost of form work and reinfircement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately ) Anx-A_394
395 395 (I) Using mixture machine Anx-A_395
396 396 ii ) Columns, pillars, posts, struts, suspanded floor, roof, landing, shelf and support, balcony, lintel,sill band , beam, girder, cantilever,staircase (except spiral staircase and landing) including preparing of top surface and finishing of nosing. Anx-A_396
397 397 N) Without using admixture, plasticiser Anx-A_397
398 398 b) M 20 grade concrete or Prop 1:1.5:3 Anx-A_398 39.08 CU.M.
399 399 Extra over item Nos.2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level. Anx-A_399 39.08 CU.M.
400 400 BRICK WORK Anx-A_400
401 401 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in in super structure above plinth upto first floor level (protruding M.S. rod / Tor steel of column to be embeded in cement morter and will be measured and paid separately) Anx-A_401
402 402 (A) 112 mm thick brick wall Anx-A_402
403 403 a) In cement morter in proportion 1:4( 1 cement :4 sand) Anx-A_403 199.87 SQ.M.
404 404 Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. Anx-A_404 199.87 SQ.M.
405 405 SHUTTERING AND FORM WORK Anx-A_405
406 406 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for insitu reinforced cement concrete and plain concrete work in Anx-A_406
407 407 Columns, Pillars , Posts & Strut Anx-A_407
408 408 a) Square, Rectangular, polygonal in plan or any shape like Tee/ L etc having plane vertical face. Anx-A_408
409 409 I) Using 38 mm thick plank Anx-A_409 58.14 SQ.M.
410 410 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.2.1 & 3.2.3(b). Anx-A_410 58.14 SQ.M.
411 411 Sides and soffits of beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties Anx-A_411
412 412 a) For depth not exceeding 1.0M Anx-A_412
413 413 I) Using 38 mm thick plank Anx-A_413 74.25 SQ.M.
414 414 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.2.1 & 3.2.3(b). Anx-A_414 74.25 SQ.M.
415 415 iii) Flat surface such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas balconies and the like. Anx-A_415
416 416 a) Floors etc. upto 200 mm in thickness Anx-A_416
417 417 I) Using 38 mm thick plank Anx-A_417 167.48 SQ.M.
418 418 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.2.1 & 3.2.3(b). Anx-A_418 167.48 SQ.M.
419 419 Providing form work of 12 mm thick plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in -situ reinforced concrete works upto 1st floor level. Anx-A_419
420 420 a) Thickness not exceeding 200mm Anx-A_420 7.34 SQ.M.
421 421 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.2.1 & 3.2.3(b). Anx-A_421 7.34 SQ.M.
422 422 PLASETRING AND POINTING Anx-A_422
423 423 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. Anx-A_423
424 424 A) On rough side Anx-A_424
425 425 b) In cement mortar 1:4 Anx-A_425 199.87 SQ.M.
426 426 Extra over item on 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every addl floor or part there of including curing complete as directed. Anx-A_426 199.87 SQ.M.
427 427 (a) On Single coat plaster Anx-A_427
428 428 B) On fair side Anx-A_428
429 429 b) In cement mortar 1:4 Anx-A_429 603.69 SQ.M.
430 430 Extra over item on 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every addl floor or part there of including curing complete as directed. Anx-A_430
431 431 (a) On Single coat plaster Anx-A_431 603.69 SQ.M.
432 432 Extra for plastering on celling and soffits of stair up to 1st floor level (instead of plastering on walls) including curing complete as directed. Anx-A_432 345.68 SQ.M.
433 433 FLOORING, PAVING AND ROOFING : Anx-A_433
434 434 40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed. Anx-A_434 238.44 SQ.M.
435 435 Cement plaster skirting with cement mortar ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement including rounding of juctions with floor. Anx-A_435
436 436 b) 20 mm thick . Anx-A_436 28.58 SQ.M.
437 437 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) Anx-A_437
438 438 a) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make Anx-A_438
439 439 ii) Of size 600mmx600mm and above Anx-A_439 148.88 SQ.M.
440 440 WOOD WORK Anx-A_440
441 441 Providing wood work in frames (chowkat) of doors, windows, clearstory windows and other similar works wrought, framed and fixed in position in contact with C.C. or brick masonry walls including supplying, fitting and fixing with nails, screws, bolts and nuts complete with M.S. plate hold fasts (4mm X 3mm X 250mm) as per design and embeded in cement concrete block in prop. 1:1:4 and with 2 coats of kiricide oiling to the timber faces in contact with C.C. and masonry as directed and specified. Anx-A_441
442 442 a) With sal wood Anx-A_442 0.41 CUM
443 443 Providing and fixing flush door shutters solid core construction with frame of first class hard wood with cross bend and face veneered plywood face panels conforming to relevant I.S. Code including oxidised iron butt hinges (100X75X3.5mm) 6 nos. with necessary wood screws. Anx-A_443
444 444 a) Decorative type face panel and block board core . Anx-A_444
445 445 I) 40 mm thick Anx-A_445 12.6 SQ.M.
446 446 STEEL AND IRON WORK Anx-A_446
447 447 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for RCC work / RB walling including straightening, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete ( upto first floor level ). Anx-A_447
448 448 a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL Anx-A_448
449 449 (ii)Super Ductile (SD) TMT reinforcement bars Anx-A_449 46.02 QNTL
450 450 Extra over item 18.1.1(a,b,c) for each subequent floor or part thereof above first floor level. Anx-A_450 46.02 QNTL
451 451 Providing, fitting and fixing M.S. Grill of required pattern for winddows / clearstory windows / openings with M.S. flats at required spacing and farmed alround square or round M.S. bars with round headed bolts and nuts or screws. Anx-A_451
452 452 II) Ornamental Grill Anx-A_452
453 453 C) Fixed to brickwork /P.C.C./R.C.C. Anx-A_453 324.27 Kg
454 454 Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand (HINDALCO/NALCO/BALCO/JINDAL/OTHER equivalent primary producer ) without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. Anx-A_454
455 455 a) 3 track sliding window . Anx-A_455
456 456 ii) 5 mm frosted glass Anx-A_456 12.96 SQ.M.
457 457 Applying primary coat over new steel and other metal surfaces upto 100 mm in width or grith after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes fine steel wood scrappers and sand paper. Anx-A_457 130.84 SQ.M.
458 458 a) With ready mixed red lead red oxide primer Anx-A_458
459 459 Painting two coats ( excluding priming coat ) on new steel and other metal surfaces with enamel paint of approved brand and manufacture( Asian paint/Berger paint/ICI paint/ J &Npaint/Nerolac to give an even shade including cleaning the surface of all dirt, dust and other foreign matter . Anx-A_459
460 460 (I) Surfaces over 100 mm in width or girth Anx-A_460 130.84 SQ.M.
461 461 b) High gloss ( Asian paint/ Berger paint/ ICI paint / J& N paint / Nerolac) Anx-A_461
462 462 Applying priming coat over new wood based surfaces over 10 cm in width/grith after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. Anx-A_462
463 463 a) With ready mixed paint, wood primer ( white). Anx-A_463 31.5 SQ.M.
464 464 Painting two coats ( excluding priming coat ) on new wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of ditrt, dust and other foreign material , sand papering and stopping Anx-A_464
465 465 (I) Surfaces over 100 mm in width or girth Anx-A_465
466 466 b) High gloss (Asian Paint/ Berger Paint /ICI paint/Nerolac Anx-A_466 31.5 SQ.M.
467 467 Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/ Berger/Dulux (ICI)/ Nerolac over concrete/cement plaster/ brick walls ( internal )and after removing all the loosely adhering material from the wall/ceiling surface with the help of emerey stone ,putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. Anx-A_467 597.01 SQ.M.
468 468 Applying one coat of distemper primer of approved brand and manufacture on wall surfaces after thoroughly brushing the surface free from mortar drops and other foreign matter and including preparing the surface even and sand papered smooth. Anx-A_468 597.01 SQ.M.
469 469 Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. Anx-A_469
470 470 (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) Anx-A_470 597.01 SQ.M.
471 471 Providing one coat of cement primer( on ext. wall) of approved brand and manufacture on new surfaces after thoroughly brooming the surface preparing the surface even and sand papered smooth. Anx-A_471 148.41 SQ.M.
472 472 Finishing old /new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish , finish of Sandex Matt brand of Snowcem India Ltd. Of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels ( two coats) Anx-A_472 148.41 SQ.M.
473 473 HARDWARE FITTINGS Anx-A_473
474 474 Supplying, fitting and fixing anodised alluminium fittings of approved make reasonably smooth, free from sharp edges, flows and necessary aluminium screws etc. complete ( annodised to a bright natural mat or stain finish ). Anx-A_474
475 475 a) Sliding door bolts Anx-A_475
476 476 I) 300 X 16 mm Anx-A_476 6 EACH
477 477 b) Tower bolt Anx-A_477
478 478 I) 300 X 12 mm Anx-A_478 2 EACH
479 479 ii) 150 X 10 mm Anx-A_479 2 EACH
480 480 c) Door handle Anx-A_480
481 481 I) 150 mm Anx-A_481 2 EACH
482 482 ii) 100 mm Anx-A_482 2 EACH
483 483 e) Butt hinge v) 100 mm x75mmx 4mm Anx-A_483 8 pair
484 484 WATER SUPPLY & SANITARY WORK Anx-A_484
485 485 Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. Anx-A_485
486 486 a) In exposed surfaces or in trenches. Anx-A_486
487 487 (ii) 110mm dia Anx-A_487 52.2 R.M.
488 488 Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. Anx-A_488
489 489 a) In exposed surfaces or in trenches Anx-A_489
490 490 ii) 110 mm dia. Anx-A_490 10 Each
491 491 Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. Anx-A_491
492 492 a) In exposed surfaces or in trenches Anx-A_492
493 493 ii) 110 mm dia. Anx-A_493 10 Each
494 494 Supplying fiting and fixing PVC plain single tee of (Supreme /Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. Anx-A_494
495 495 a) In exposed surfaces or in trenches Anx-A_495
496 496 ii) 110 mm dia. Anx-A_496 5 Each
497 497 Providing fitting and fixing 100 mm dia PVC Cowel with ISI make complete as directed and specified. Anx-A_497 5 Each
498 498 INTERNAL ELECTRIFICATION WORK Anx-A_498
499 499 Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Anx-A_499
500 500 b)Medium point upto 6.00mtr length Anx-A_500 30 Per point
501 501 c)Long point upto 10.00mtr length Anx-A_501 25 Per point
502 502 Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Anx-A_502
503 503 b)Medium point upto 6.00mtr length Anx-A_503 4 Per point
504 504 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\n Anx-A_504
505 505 Extra long point up to 25.00 metre. Length. Anx-A_505 4 per point
506 506 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. Anx-A_506
507 507 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. Anx-A_507 85 per mtr
508 508 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. Anx-A_508 55 per mtr
509 509 With 2 x 16 sq. mm. + earth continuity with 1x10 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. Anx-A_509 25 per mtr
510 510 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Anx-A_510
511 511 12 way SPN double door Anx-A_511 2 EACH
512 512 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Anx-A_512
513 513 6 way TPN (4+18) double door Anx-A_513 2 EACH
514 514 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. Anx-A_514
515 515 B Series\n(Schneider MG, legrand, Hager make) Anx-A_515
516 516 6 to 32A Anx-A_516 20 EACH
517 517 Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. Anx-A_517
518 518 B Series\n(Schneider MG, legrand, Hager make) Anx-A_518
519 519 63A Anx-A_519 2 EACH
520 520 MCCB with Thermal & Magnetic Release Anx-A_520
521 521 Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. Anx-A_521
522 522 25 KA 415V 50 Hz 3P MCCB \n(Schneider, legrand, Siemens make) Anx-A_522
523 523 16A Anx-A_523 2 EACH
524 524 63A Anx-A_524 2 EACH
525 525 Supplying including fitting and fixing of high speed AC Ceiling fan complete with all accessories like , down rod, canopy etc.of following sweeps with making necessary connection etc.as reqd complete and directed by the deptt.(Without regulator) Anx-A_525
526 526 a) 1400mm sweep Anx-A_526 16 each
527 527 Installation ,testing and commissioning of ceiling fan including the regulator, down rod of standard size(up to 300mm length) and connection etc complete as specified and directed by the department. Anx-A_527 16 each
528 528 Supplying and fixing Call bell(Buzer) including 5 Amps capacity flush type bell push switch including connections as approved by the Deptt as required . Anx-A_528 4 each
529 529 Supplying fitting and fixing of single wall brackets model 37712 (or equivalent as approved by the Deptt.) on the wall in GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover with all accessories including connection as required complete. Without lamp. Anx-A_529 6 each
530 530 Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. Anx-A_530
531 531 Striplite luminaries complete with VPIT copper ballast/ Electronic ballast and decorative end cap and 1 X 36 / 40 watt Fluorescent tube.(Crompton Greaves make) Model- DSG1114LDB CROMGOLD / DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD / DSG 1414EB PLANET GOLD with Super Saver / Super Brite Lamp. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make. Anx-A_531 16 each
532 532 WVF 53414 SGW 4 x 14 W FTL T5) Recess mounted indirect- direct luminaries with High Efficiency Translucence (HET) Technology suitable for FTL T5) Lamps. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ JAQUAR make). Anx-A_532 2 each
533 533 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . Anx-A_533
534 534 185.00 Sq.mm 4 Core U.G. cable in 80 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) Anx-A_534 15 mtr
535 535 Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . Anx-A_535 2 each
536 536 Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. Anx-A_536 2 each
537 537 Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. Anx-A_537 3 mtr
538 538 Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. Anx-A_538 3 mtr
539 539 Supplying & laying of 25x4 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt. Anx-A_539 3 per mtr
540 540 Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt. Anx-A_540 1 Each
541 541 Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt. Anx-A_541 6 Each
542 542 Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG1.66mm) thick CR sheet and 35 mm × 35 mm × 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items. Anx-A_542
543 543 1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no Anx-A_543
544 544 2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos. Anx-A_544
545 545 3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set Anx-A_545
546 546 4. 40 Amp 4 pole ON-OFF poser contactor - 1 No. Anx-A_546
547 547 5. Surface mounting timer switch - 1 No. Anx-A_547
548 548 6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos Anx-A_548
549 549 7. 0-40 Amp electro-mechanical counter display 3 Phase 4 wire electronic hybrid energy meter Anx-A_549 1 Each
550 550 3.Name of work: Renovation /Up gradation of Library Building at Purbanchal College, Silapathar, District, Dhemaji, Assam, under new construction schemes of RUSA for the year 2018-2019 . Anx-A_550
551 551 CIVIL WORK Anx-A_551
552 552 Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels. Anx-A_552
553 553 (ii) Prop (1 : 3 : 6) or richer mix Anx-A_553 150 SQ.M.
554 554 FLOORING : Anx-A_554
555 555 18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. Anx-A_555
556 556 (i) Marwat Slab Anx-A_556 336 SQ.M.
557 557 Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. Anx-A_557
558 558 (A) CERAMIC Anx-A_558
559 559 a) Deluxe -VC Anx-A_559 27 SQ.M.
560 560 Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). Anx-A_560
561 561 ii) Of size150mmx605mm and above (Strips) Anx-A_561 79 SQ.M.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail