Sales : +91-777 804 8217
| Name of Work: DETAILS ESTIMATE FOR THE CONSTRUCTION OF PROPOSED MRF (MATERIAL RECOVERY FACILITY CENTER | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | 1 -Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. | BI01010001010000000000000515BI0100001113 | 84.62 | CUM |
| 2 | 2 | 2- Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. | BI01010001010000000000000515BI0100001114 | 29.954 | CUM |
| 3 | 3 | 3- Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. | BI01010001010000000000000515BI0100001115 | 409.35 | CUM |
| 4 | 4 | 4- Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) | BI01010001010000000000000515BI0100001116 | 272.7 | SQM |
| 5 | 5 | 5- R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. Same as above but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001117 | 10.349 | CUM |
| 6 | 6 | 6- Same as above but for the Slab i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001118 | 0.35 | CUM |
| 7 | 7 | 7- As in item 6 above but in R.C.C. Raft foundation and footing with approved stone ballast.(Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001119 | 10.98 | CUM |
| 8 | 8 | 8- As in item 6 above but in Column with approved stone ballast.(Using 1:1.5:3 Mix concrete). | BI01010001010000000000000515BI0100001120 | 7.34 | CUM |
| 9 | 9 | 9- Class M-150 brick work in 1:6 cement coarse sand (of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. | 8.633 | CUM | |
| 10 | 10 | 10- Class-150 brick work in 1:6 cement and Coarse sand mortar in Super structure including supply of all materials, labour tools and plants, etc. required for proper completetion of the work. | 29.208 | CUM | |
| 11 | 11 | 11- Class-150 HALF brick work in 1:4 cement and COARSE sand mortar in SUPERSTRUCTURE including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. | 1.733 | CUM | |
| 12 | 12 | 12- P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. | 27.987 | QTL | |
| 13 | 13 | 13- 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand. | 114.36 | SQM | |
| 14 | 14 | 14- 15mm Cement plaster in single coat of Rough side of single of half brick wall for exterior plastering upto floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm. In girth and finished even and smooth No. extra for mixing any additive. 1 cement : 6 fine sand | 217.41 | SQM | |
| 15 | 15 | 15- Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). | 249.794 | SQM | |
| 16 | 16 | 16- Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes | 3724.27 | KG. | |
| 17 | 17 | 17- Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/m² | 327.87 | SQM | |
| 18 | 18 | 18- Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m² | 27.8 | RM | |
| 19 | 19 | 19- Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.63 mm thick with zinc coating not less than 275 gm/m² | 54.4 | RM. | |
| 20 | 20 | 20- Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. For Steel Surface. | 4263.76 | SQM | |
| 21 | 21 | 21- Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. For Wooden Surface. | 11.34 | SQM | |
| 22 | 22 | 22- P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. | 739.8 | KG. | |
| 23 | 23 | 23- Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm | 119.49 | Sqm | |
| 24 | 24 | 24- M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. (a) Angle iron door chaukhats 40*40*5 | 49.92 | KG | |
| 25 | 25 | (b) Z-Section with M.S. Grill | 189 | KG | |
| 26 | 26 | 25- Fixing of Door, windows/ventilators chaukhats in position. (a) Door chaukhats | 3 | NOS | |
| 27 | 27 | (b) Window chaukhats | 3 | NOS | |
| 28 | 28 | 26- Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes | 5.4 | SQM. | |
| 29 | 29 | 27- Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws single leaf | 5.67 | SQM | |
| 30 | 30 | 28- Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm | 3 | NOS | |
| 31 | 31 | 29- Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (a) 250 mm x 10mm | 3 | NOS | |
| 32 | 32 | 30- Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm | 6 | NOS | |
| 33 | 33 | 31- Finishing walls with water-proofing on cement paint of approved make such as super snowcem, durrocem, robiacem, guttucem supercem quality and of required shade on undecorated wall surfaces (two coat) overone and including one coat white after thoroughly brushing the surface to powdered materials including curing and cost of all materials. | 331.77 | SQM | |
| 34 | 34 | 32- Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter | 21 | RM. | |
| 35 | 35 | 33- Filling of carted earth. | 599.93 | cum | |
| 36 | 36 | 34- ADD EXTRA FOR 6 WATER TAPS IN WASHING UNIT | 1 | nos | |
| 37 | 37 | 1- Wiring points for light with 1.5 sqmm.FRLSH PVC insulated single core aluminium condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. | 11 | Each | |
| 38 | 38 | 2- Same as item No. (1) but for fan and light duty exhaust fan. | 7 | Each | |
| 39 | 39 | 3- Same as item No.(1) but for 5 amp plug point with piano type switch and socket etc. | 1 | Each | |
| 40 | 40 | 4- Supply & fixing of industrial bulk head fitting of cast aluminium body, having heat resistant glass cover and M.S. galvanized wire guard suitable for and with 9/10 watt CFL complete in all respect. | 8 | Each | |
| 41 | 41 | 5- Supply & fixing of LED Tube Light with batten suitable for up to 1 x 22 watt LED tube light complete including tube etc on surface complete in all respects.(CAT: AA) | 3 | Each | |
| 42 | 42 | 6- Supply and burying of 40mm dia x 4.5meters long G.I. pipe, vertically for earthing having 12 mm dia. Holes spaced 75mm apart drilled upto 2 meters from the bottom complete with earthing lead of no 6 to 8 SWG GI wire in GI pipe upto appron (and from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I. box with hinged cover, masonary enclosue, funnel at top, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. | 1 | Each | |
| 43 | 43 | 7- Supply & fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the wirk as directed at site. | 15 | Metre | |
| 44 | 44 | 8- Supply and fixing of 240 volts 'L' series miniature circuit breaker 9 K.A / 10 K.A.in existing MCB, DB complete with connections as required. (a) 5 - 32 amps. | 2 | Each | |
| 45 | 45 | 9- Supply and fixing of flush/surface mounting distribution boards complete in all respects. (a) 8Way SPN | 1 | Each | |
| 46 | 46 | 10- Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects. | 5 | Each | |
| 47 | 47 | 8- Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cutting and making good the walls & floors as per requirement. (a) 150mm | 85 | Metre | |
| 48 | 48 | 9- Supply and erection of AC 1200mm Sweep, 220/240 Volts, 50 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required | 5 | each | |
| 49 | 49 | 1- Wiring points for light with 1 sqmm.FRLSH PVC insulated single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. | 4 | Each | |
| 50 | 50 | 2- Supply & fixing of fancy type round ceiling fitting made of polycarbonate suitable for and with 1x15/18 watt CFL complete in all respect. | 4 | Each | |
| 51 | 51 | 3- Supply & fixing of industrial bulk head fitting with polycarbonate base guard, prismatic reflector silicon gasket suitable for and with 1 x 18 Watt CFL complete in all respect | 2 | Each | |
| 52 | 52 | 1- Excavation for all types and sizes of foundations, trenches and drains of for any other purpose including disposal of excavated stuff up to 1.5m lift and lead up to 50m (At least 5m away from the excavated area), including dressing and leaving of pits. In all types of soil. | 19 | cum | |
| 53 | 53 | 2- Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work. 1:4:8 (1 cement:4 coarse sand:8 graded stone aggregate 40mm nominal size) | 4 | cum | |
| 54 | 54 | 3- Class M-150 brick work in 1:6 cement coarse sand (of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. | 27.55 | cum | |
| 55 | 55 | 4- Providing and fixing in position chain linked steel wire fabric made of 4mm dia G.I wire of required width in mesh to concrete/wooden/angle iron posts including securing and screwing with 2mm dia G.I wire, G.I staples, G.I.U-nails or steel Pins etc. Complete Aperture 50×50mm | 170 | sqm | |
| 56 | 56 | 5- Providing and placing in position angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for required length and drilling holes upto 10mm dia. as per requirement including priming coat with red oxide zinc chromate primer and placing the post/strut in cement concrete block. | 1271.29 | Kg | |
| 57 | 57 | 6- Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works 1:2:4 (1 cement:2 coarse sand 4graded stone aggregate 20mm nominal size) | 0.79 | cum | |
| 58 | 58 | 8- 12mm thick cement plaster of mix:In cement Mortar 1:6 (1 cement :6 fine sand) | 105 | sqm | |
| 59 | 59 | 9- 12mm thick cement plaster of mix: In Cement mortar 1:6 (1 cement:6 fine sand) | 85 | sqm | |
| 60 | 60 | 10- Finishing walls with water proofing cement paint of required shade to give an even shade.On New work (Two or more coats [email protected]/10sqm) | 190 | sqm | |
| 61 | 61 | 1- Excavation in foundation in ordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth as directed by the engineer I/C within a lead of 30 m.from foundation trenches. | 17.99 | Cum | |
| 62 | 62 | 2- Class-150 brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. | 13.65 | Cum | |
| 63 | 63 | 3- Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. | 6 | Cum | |
| 64 | 64 | 4- Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. | 121.5 | Sqm | |
| 65 | 65 | 1- Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. | 9.829 | CUM | |
| 66 | 66 | 2- Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. | 2.791 | CUM | |
| 67 | 67 | 4- Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) | 7.17 | SQM | |
| 68 | 68 | 5- R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. (a) Ground Floor | 0.607 | CUM | |
| 69 | 69 | 6- As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) (a) Ground Floor | 0.929 | CUM | |
| 70 | 70 | 7- M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. | 11.061 | CUM | |
| 71 | 71 | 8- Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) | 2.141 | SQM | |
| 72 | 72 | 9a- Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. | 2.141 | SQM | |
| 73 | 73 | 9- Same as in item No. 11 above but in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) (a) Ground Floor | 4.763 | CUM | |
| 74 | 74 | 10- Same as in item no. 9 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. (a) Ground Floor | 1.643 | CUM | |
| 75 | 75 | 11- P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (a) Ground Floor | 1.06 | QTL | |
| 76 | 76 | 12- 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. | 3.989 | SQM | |
| 77 | 77 | 13- 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand (a) Ground Floor | 17.903 | SQM | |
| 78 | 78 | 14- 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand. (a) Ground Floor | 49.704 | SQM | |
| 79 | 79 | 15- Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey,\nFume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.. (a) Ground Floor | 4.51875 | SQM | |
| 80 | 80 | 16- Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (a) Ground Floor | 14.952 | SQM | |
| 81 | 81 | 17- Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). | 8.568 | SQM | |
| 82 | 82 | 18- Providing and fixing of Flush doors commercial quality conforming to I.S. 2202 part-I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts locks, handles spring fitting with necessary screws to be supplied departmentally. 30 mm thick (a) Single leaf | 4.725 | SQM | |
| 83 | 83 | 19- M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. (a) Providing & fixing of hold fast for chaukhats of doors and windows. | 13.2 | KG | |
| 84 | 84 | (b) Providing & fixing of door / windows grill. | 8.1 | KG | |
| 85 | 85 | (c) Z-Section steel windows (openable) | 9.18 | KG | |
| 86 | 86 | (d) Angle iron door chaukhats 40*40*5 | 44.55 | KG | |
| 87 | 87 | 20- Fixing of Door, windows/ventilators chaukhats in position. (a) Door chaukhats | 3 | NOS | |
| 88 | 88 | 20 (b) Ventilator chaukhats | 2 | NOS | |
| 89 | 89 | 21- White washing two coat including supply of all materials, labour and T & P etc. required for proper completion of the work. (a) Ground Floor | 17.903 | SQM | |
| 90 | 90 | 22- Finishing wall with water proof cement paint of approved make and quality on new work with three coats to give an even shade including supply of all materials, labour and T & P etc. required for proper completion the work. Two Coat (a) Ground Floor | 49.704 | SQM | |
| 91 | 91 | 23- White washing two coat including supply of all materials, labour and T & P etc. required for proper completion of the work. (a) Ground Floor | 5.021 | SQM | |
| 92 | 92 | 24- Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . | 6 | NOS | |
| 93 | 93 | 25- Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm | 6 | NOS | |
| 94 | 94 | 26- Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. | 5.7 | SQM | |
| 95 | 95 | 27- Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. | 3.375 | SQM | |
| 96 | 96 | 28- Same as item 27 above but on new wood surface. | 9.45 | SQM | |
| 97 | 97 | 29- Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes | 0.54 | SQM | |
| 98 | 98 | 1- Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests | 3 | each | |
| 99 | 99 | 2- Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: Range of Two half stall urinals with 5 litre PV.C. automatic flushing cistern. | 1 | each | |
| 100 | 100 | 3- Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade | 1 | Sqm. | |
| 101 | 101 | 4- CP Brass fittings Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore | 5 | each | |
| 102 | 102 | 5- Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (a) 15 mm nominal bore | 3 | each | |
| 103 | 103 | 1- Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110 mm dia | 5 | metre | |
| 104 | 104 | 1(a)- 90 mm dia | 5 | metre | |
| 105 | 105 | 2- Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm | 3.5 | Metre | |
| 106 | 106 | 3- Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend | 1 | Each | |
| 107 | 107 | 3(a) Shoe (Plain) 110 mm Shoe | 1 | Each | |
| 108 | 108 | 4- Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. | 1 | Each | |
| 109 | 109 | 5- Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm | 2 | Each | |
| 110 | 110 | 6- Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. | 1 | Each | |
| 111 | 111 | 1- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. Concealed work 20mm dia nominal outer dia pipes | 5 | Rm. | |
| 112 | 112 | 1(a)-25mm dia nominal outer dia pipes | 5 | Rm. | |
| 113 | 113 | 2- Exposed on wall Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). Internal work-Exposed on wall 20mm dia nominal bore | 5 | Metre | |
| 114 | 114 | 3- Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work. 20mm dia nominal bore | 5 | Metre | |
| 115 | 115 | 4- Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). 20mm dia nominal bore | 2 | Each | |
| 116 | 116 | 5- Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore | 1 | Each | |
| 117 | 117 | 6- Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Capcity in Per Liters | 500 | nos | |
| 118 | 118 | 1- Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. | 3 | metre | |
| 119 | 119 | 2- Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter | 3 | metre | |
| 120 | 120 | 3- Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design. 100mm dia SW pipe | 3 | metre | |
| 121 | 121 | 4- Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 | 1 | each | |
| 122 | 122 | 1- Providing and fixing on wall face unplasticised Rigid PVC soil and waste water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. (a) 110mm dia P.V.C. pipe | 10 | Rm | |
| 123 | 123 | 1-(b) 90mm dia P.V.C. pipe | 5 | Rm | |
| 124 | 124 | 2- Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 110 mm | 3 | Nos. | |
| 125 | 125 | 3- Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 110mm bend | 5 | Each | |
| 126 | 126 | 3(a)- 90 mm bend | 3 | Each | |
| 127 | 127 | 3(b)- Coupler 110mm | 10 | Each | |
| 128 | 128 | 3(b)- 90mm | 5 | Each | |
| 129 | 129 | 4- Providing and fixing pvc Inlet fitting with 2 inlets 80 mm size fabricated from 110 mm dia PVC pipes(approx. length=150mm to 300mm) and fixed to PVC trap with joint and set in cement concrete as per standard drawing complete. | 2 | Each | |
| 130 | 130 | 1- Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks | 2 | NO | |
| 131 | 131 | 1- Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | 336 | KG | |
| 132 | 132 | 2- Painting one coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. | 16.8 | SQM | |
| 133 | 133 | 2- Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. | 32.4 | cum | |
| 134 | 134 | 3- Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by ippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per pecifications and directions of Engineerin- Charge With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 | 4.86 | cum | |
| 135 | 135 | 4- Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). | 4.86 | cum | |
| 136 | 136 | A- External W/S arrangement, T.W. boring of 150mm dia with 100mm dia P.V.C. pipe assembly, 1.5 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangement etc. 1 - 100mm dia PVC pipe of ISI mark [14 Kg pressure] | 60 | RM | |
| 137 | 137 | 2- P/F 2\" PVC pipe | 40 | RM | |
| 138 | 138 | 3- NYLon mesh for filter | 1 | Roll | |
| 139 | 139 | 4- Plastic dori | 1 | Gulla | |
| 140 | 140 | 5- Solvent dori | 1 | L.t | |
| 141 | 141 | 6- 4\" End cap | 1 | NO. | |
| 142 | 142 | 7- 4\" Submersible Cap | 1 | No. | |
| 143 | 143 | 8- 2\" MS clamp (Heavy) | 1 | Pair | |
| 144 | 144 | 9- 2\" Gl elbow. | 1 | No. | |
| 145 | 145 | 10- 2\"*6\" GI nipple | 1 | NO. | |
| 146 | 146 | 11- 1.5 HP 9 Stage Submersible Pump of ISI mark With automatic panel. | 1 | NO. | |
| 147 | 147 | 12- 2.5 Sqm. Submersible cable. | 60 | mt. | |
| 148 | 148 | 13- Drilling Charges for 6\" dia tubewell. | 60 | mt. | |
| 149 | 149 | 14- Pea Gravel | 1 | Cm. | |
| 150 | 150 | 15- 2\" Ms Socket. | 4 | No. | |
| 151 | 151 | 16- Cartage of material upto site. | 1 | ls | |
| 152 | 152 | 17- ADD COST OF EXTERNAL ELECTRIC CONNECTION | 1 | no |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy