Construction Of Primary Processing Centre On Potao For Sankar Azan Agro Producer Company Ltd At M Azad Road Barabazar Ward No 14 Nagaon Assam 782003 Group No 8, Barabazar Nagaon-Assam

Assam Industrial Infrastructure Development Copr-AIIDC has published Construction Of Primary Processing Centre On Potao For Sankar Azan Agro Producer Company Ltd At M Azad Road Barabazar Ward No 14 Nagaon Assam 782003 Group No 8. Submission Date for this Tender is 07-03-2020. Building Work Tenders in Barabazar Nagaon Assam. Bidders can get complete Tender details and download the document.




Tender Notice

23734011
Construction Of Primary Processing Centre On Potao For Sankar Azan Agro Producer Company Ltd At M Azad Road Barabazar Ward No 14 Nagaon Assam 782003 Group No 8
Open Tender
Indian
Assam
Barabazar Nagaon
07-03-2020

Tender Details

Construction Of Primary Processing Centre On Potao For Sankar Azan Agro Producer Company Ltd At M Azad Road Barabazar Ward No 14 Nagaon Assam 782003 Group No 8

Key Value

Document Fees
INR 700 /-
EMD
INR 71707.0 /-
Tender Value
INR 35.85 Lakhs /-

BOQ Items

Name of Work: Construction of Primary Processing Centre on Potato for Sankar Azan Agro Producer Company Ltd. at M. Azad Road, Barabazar, ward No. 14, Nagaon, Assam-782003, Group No.8
Sl. No. Item Description Item Code / Make Quantity Units
1 1 CIVIL_WORKS: Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank, etc.including refilling (return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming, etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. Upto a depth of 2.0m below the existing ground level. (a) In ordinary soil. item1 143 Cu.m
2 2 Earth / sand filling in plinth area not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With hill sand obtained by truck carriage, loading and unloading and carriage to the site of work. item2 109.2 Cu.m
3 3 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works, etc. as directed and specified including dewatering if necessary, and curing complete (Shuttering where necessary shall be measured and paid separately). In prop. 1 cement : 3 sand : 6 coarse aggregate by volume. item3 9.83 Cu.m
4 4 Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc. complete as directed. item4 15.4 Sq.m
5 5 Providing and laying plain / reinforced cement concrete works cement with coarse sand and 20mm down graded stoneaggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). M20 grade concrete or prop. 1:1.5:3 item5 71.53 Cu.m
6 6 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping, etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work. item6 373 Sq.m
7 7 Providing soling in foundation and under floor with stone / best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete. Brick on flat soling. item7 313 Sq.m
8 8 Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. In sub structure up to plinth level including dewatering if necessary. In proportion 1:4 item8 19.41 Cu.m
9 9 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately. 112mm thick brick wall. In cement morter in proportion 1:4 (1 cement :4 sand) item9 408.33 Sq.m
10 10 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. item10 182 Sq.m
11 11 20mm thick cement plaster in two coats, backing coat 15mm and finishing coat 5mm thick on rough side of single or half brick wall for interior plastering upto 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. In cement mortar 1:4 item11 856 Sq.m
12 12 Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from morter droppings and other foriegn matter and also including preparing the surface even and sand prepared smooth. item12 256 Sq.m
13 13 Finishing old/ new wall with water proofing weather coat smooth anti fungal exterior painting of approved make of Berger paint of required shade after cleaning the surface etc. including scaffolding complete at all levels (two coats). item13 256 Sq.m
14 14 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete / mortar walls and ceilling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quality of clean water as specified and directedy the department. (Total thickness of two coats is maximum 1.5mm). Thickness- 1.5mm item14 599 sqm
15 15 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture(Asian paints/Berger paint/ICI paint/ J & N paint/Nerolac) on new surface to give an even shade after throughly brushing the surface free from mortar drooping and other foreign matter and sand papered smooth. Acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J&N paint/ Nerolac) item15 599 Sqm
16 16 Supplying, fitting and fixing in position reinforcement bars conforming to relevant IS code for RCC work/RB walling including straightening, cleaning, cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers, etc. complete upto 1st floor level.. TATA/ SAIL /Jindalsteel/Shyam steel/RINL. Super ductile (SD) TMT reinforcement bars item16 61.2 Qntl.
17 17 Pre construction anti-termite treatment in the back fill in immediate contact with the foundation structureafter completion, column wall etc.to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with structure well treated-with chemical (supplying of necessary tools and accessiories by the contractor) as per the direction of department complete. With aqueous emulsion having concentration of 1:19 with chloropirophose solution (Tricel or its equivalent) and water. i.e.1% solution. item17 244 Sq.m
18 18 Pre construction anti-termite treatment - applying in the entire levelled area after plinth filling and before laying floor, tricel solution @ 5 litres per square metre of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessiories by the contractor) as per direction of the Department complete.With aqueous emulsion having concentration of 1:19 with chloropirophose solution (Tricel or its equivalent) and water. This provides emulsion containing 1% chloropirophose solution (by weight) item18 182 Sq.m
19 19 Providing, fitting, hoisting and fixing of roof trusses including purlins fabricated of M S black tubes conforming to relevant IS code, as per approved drawings and design including providing MS cleats, base plates, bolts and nuts and one coat of red oxide zinc chromate primer and two coats of approved enamel paints complete including fitting necessary cleats, etc. for fixing ceiling joists as per design and drawings as directed. item19 54.1 QTL
20 20 Providing Pre painted galvanised Iron sheets roofing (PPGI) (Dyna Roof/ Sathyam/ Durakolor? Century Wells) at all levels including fitting and fixing ridging with self drilling, self tapping screws complete (Roof trusses and prulins etc. to be measured and paid separately). 0.45mm thick. item20 237.36 Sq.m
21 21 Providing galvd. Iron ridging (24 G) Including supplying and fixing necessary galvd. Screws, washer etc. complete as directed say item21 26.27 M
22 22 Providing wood work in frame (Chowkaths) in doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with CC or brick masonary wall including supplying, fitting and fixing with MS flat hold fast (40mm x 3mm x 250mm) as per design and embedded in cement concrete block in prop 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with CC and masonary as directed and specified. (b) 1st class timber (Hollock/ Bonsum). item22 0.68 Cu.m
23 23 Providing and fixing factory made Santro or eqivalent Flush door shutters having core and crossbands fabricated from seasoned 1st class timber, 25mm core battens,2.5mm to 3.5mm uniformly thick cross bands, styles and rails made from hardwood timber of width not less than 50mm, fixed to the door frames with necessary hinges, screws, bolts etc.as specifird and directed at all levels.(Door fixtures and fittings to be measured and paid seperately). 35 mm thick item23 24.48 Sq.m
24 24 Providing, fitting and fixing steel windows/ ventilators (openable) of standard rolled steel sections as per relevant I.S. Code-1038 joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stays of 300mm long etc. complete as per drawing including applying a priming coat of red-lead paint. item24 21.24 Sq.m
25 25 Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire lenth and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters. item25 10.8 Sq.M
26 26 Providing, fitting and fixing hard board sheet ceilling with approved quality with necessary nails, wood screws including 1st class local wood 50mm x 12mm ( hollock/ bonsum/ sundi ) beading including paining two coats to timber beads complete as directed. 6mm thick. item26 182 Sq.M
27 27 Installation of Hand Tube Well, Construction of MS Stagging 3.00 m height with RCC foundation, one no. 1000 litre capacity PCVC tank including placing over the stagging, 1 HP Motor Pump set, pump shed, necessary pipe line, etc. as required complete as per drawing and specification and as directed. item27 1 Job
28 28 ELECTRICAL WORKS: CIRCUIT WIRING: Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.- With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item28 140 RM
29 29 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.- With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item29 40 RM
30 30 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.- With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item30 15 RM
31 31 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.- With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item31 20 Metre.
32 32 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.- With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item32 20 Metre.
33 33 Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan. item33 2 Each
34 34 Wiring to 5 Aa pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. Long point up to 10.00 metre length. item34 1 Each
35 35 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)- Long point up to 10.00 metre. Length. item35 5 Each
36 36 Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete- Short point up to 3.00 metre. length. item36 12 Each
37 37 Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete- Medium point up to 6.00 metre. Length. item37 10 Each
38 38 Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete- Long point up to 10.00 metre. Length. item38 8 Each
39 39 MODULAR SWITCH: Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. : 1-2 module type Metal item39 7 Each
40 40 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.: 4-5 module type Metal item40 7 Each
41 41 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.: 6-8 module type Metal item41 3 Each
42 42 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.: 10 module type Metal item42 1 Each
43 43 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 1 module item43 2 Each
44 44 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 2 module item44 5 Each
45 45 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 4 module item45 7 Each
46 46 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 6 module item46 1 Each
47 47 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 8 module item47 2 Each
48 48 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 10 module item48 1 Each
49 49 Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department. item49 5 Each
50 50 Supplying with fitting and fixing of 100 watt electronic modular fan speed controller 4 - Step 2 - module type MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. item50 1 Each
51 51 Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. item51 7 Each
52 52 Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. item52 3 Each
53 53 Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. item53 7 Each
54 54 Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. item54 34 Each
55 55 SWITCH GEAR & PROTECTION: Supplying fitting and fixing industrial Plug & Socket in surface mounting TPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of 4P MCB complete with making necessary connection etc. as specified and directed by the Deptt.- ABB, Schneider MG, legrand, Hager make)- 20A Capacity. item55 1 Each
56 56 MCB IN-comer SPN DB: Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. - ABB, Schneider MG, legrand, Hager make)- 12 way SPN double door item56 1 Each
57 57 MCB IN-comer TPN (Horizontal DB): Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. - ABB, Schneider MG, legrand, Hager make)- 8 way TPN (4+24) double door item57 1 Each
58 58 MCB, MCCB, RCCB, RCBO: Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.- C Series- (Schneider MG, legrand, Hager make)- 6 to 32A item58 20 Each
59 59 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.- C Series- (ABB, Schneider MG, legrand, Hager make)- 40A item59 1 Each
60 60 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB- (ABB, Schneider MG, legrand, Hager make). 40A item60 1 Each
61 61 Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.- C Series (ABB, Schneider MG, legrand, Hager make)- 63A item61 1 Each
62 62 EARTHING: Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . item62 2 Each
63 63 Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. item63 2 Each
64 64 Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. item64 50 Metre.
65 65 Supplying & laying of 25 x 5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt. item65 25 R.M.
66 66 FAN: Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make). Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make. [F] item66 1 Each
67 67 U. G. CABLE AND CABLE WORKS: Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make).- 3 & 1/2 Core A2XFY- 185.00 Sq. mm 3 & 1/2 Core armoured U.G. cable item67 30 Metre
68 68 Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)- Core - 3 & 1/2 A2XWY A2XFY- 185.00 Sq.mm 3&1/2 Core U.G. cable in 80 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) item68 5 Metre
69 69 Supplying including installation of cast iron cable marker as specified and directed by the deptt. item69 5 Each
70 70 OVER HEAD LINE: Supplying and fitting fixing of H.T./L.T. danger plate complete as required and as directed by the department. item70 2 Each
71 71 Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department.- B118601000 [FL] item71 3 Each
72 72 Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department.- BN021C LED 20 PSU CW GR S2 [TL] item72 27 Each
73 73 NON-SCHEDULE_ITEM:_LT_PANEL: Supplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). Panel should be made of sheet steel and thickness not less than 2mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The panel shall be incorporated with double busbar system. The bus bar shall be of high quality copper of uniform cross section. The panel shall consist of the following items (viz. Voltmeter, Ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel.- Incommer: - 250A 4P 36 KA MCCB - 1 No. - Bus-Bars: 480 A TPN Electrolytic Copper Bus Bar of Size (30mmX10mm) – 1 set- Digital Panel Mounted Energy (Kwh) Meter- 1No.- Digital Panel mounted Voltmeter - 1 No. - Digital panel mounted Ammeter - 1 No. - Voltmeter Selector Switch - 1 No. - Ammeter Selector Switch - 1 No. - Indicating Lamps - 3 Nos. - CT - 3 Nos. - Fuse holders & Fuse bases suitable for Cylindrical / DIN fuse-links and Fuse - 6 Nos. - Outgoing:- 160 A 4P MCB - 1 No.- 63 A 4P MCB - 2 Nos.- 40 A DP MCB - 3 Nos. - 32 A DP MCB - 3 Nos. item73 1 Set
74 74 Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade item74 2 Sq.m
75 75 Supply, Fitting Fixing of Shock Treatment Chart item75 2 Each