| 1 | 1 | SCHEDULE \"A\" Part - I (BUILDING WORKS)\nDetails of prepriced schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 2 | 2 | SCHEDULE \"A\" PART-II ( SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK) \nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 3 | 3 | SCHEDULE \"A\" PART-III (INTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 4 | 4 | SCHEDULE \"A\" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 5 | 5 | SCHEDULE \"A\" PART-V (ROAD/PATH/CULVERT)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 6 | 6 | SCHEDULE \"A\" PART-VI (SEWAGE DISPOSAL)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 7 | 7 | SCHEDULE \"A\" PART-VII (AREA DRAINAGE)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 8 | 8 | SCHEDULE \"A\" PART-VIII (EXTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 9 | 9 | SCHEDULE \"A\" PART-IX \n(EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 10 | 10 | SCHEDULE \"A\" PART-X (SOLAR WATER HEATER)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 11 | 11 | SCHEDULE \"A\" PART-XI\n(CONDUIT FOR TELEPHONE)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 12 | 12 | SCHEDULE \"A\" PART-XII \n(STREET LIGHT)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 13 | 13 | SCHEDULE \"A\" PART-XIII\n(DEMOLITION AND DISMANTLING)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 14 | 14 | SCHEDULE \"A\" PART -XIV (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.' E ' signifies this fact only. | | | |
|---|
| 15 | 15 | INTERNAL WATER SUPPLY\nSupply & fixing 20 mm dia regular body concealed stop cock Jaguar make (ALD-089Ft) or equivalent crabTree/Kohler brand. Exposed part kit Jaguar make ( CON-083FTK) or equivalent of concealed stop cock with fitting sleeve etc complete screwed both ends for pipe or for unions and fixed suitable for 20 mm bore of pipe , complete all as specified. | | 142 | Each |
|---|
| 16 | 16 | Supply & fixing 20 mm dia Jaguar make Angular stop cock (CON-053KN) or equivalent in Crab Tree/Kohler brand. complete all as specified. | | 639 | Each |
|---|
| 17 | 17 | Supply & fixing 20 mm dia Jaguar make 2 way bib cock (CON-041KN) or equivalent in Crab Tree/Kohler brand. complete all as specified. | | 95 | Each |
|---|
| 18 | 18 | Supply & fixing brass CP mixer for mixing hot and cold water screwed down for iron pipe and fixed . complete all as specified. MAKE- JAQUAR CAT PART NO- FUS 29281 OR EQUIVALENT IN CRAB TREE / KOHLER \n | | 30 | Each |
|---|
| 19 | 19 | Supply & fixing brass chromium plated shower rose complete all as specified. MAKE- JAQUAR CAT PATNO- OMS-CHR-497N OR EQUIVALENT IN CRAB TREE / KOHLER | | 172 | Each |
|---|
| 20 | 20 | Supply and fixing hand jet health faucet 20mm bore with all connected fittings as per cat part noalu-577) or equivalents in crab tree/kolhar complete all as specified | | 101 | Each |
|---|
| 21 | 21 | INTERNAL ELECTRIC SUPPLY\nS & F modular type bell ding dong of 2 module size, conforming to IS: 8884- 1978 complete all as specified and directed.\nMake: Legrand Arteor Cat-Part No. 5734 43/ Hager (Berker)/Schneider(Zencelo) | | 89 | Each |
|---|
| 22 | 22 | S & F modular type 1 module TV socket complete all as specified and directed. \nMake: Legrand Arteor Cat-Part No. 5734 25 /Hager (Berker)/Schneider(Zencelo) | | 83 | Each |
|---|
| 23 | 23 | S & F modular type 1 module telephone socket complete all as specified and directed. \nMake: Legrand Arteor Cart-Part No. 5734 26 /Hager (Berker)/Schneider(Zencelo) | | 77 | Each |
|---|
| 24 | 24 | S & F factory made screwless, dust proof cover plates having superior finish, rounded corners, and solid strength supported by plastic frame behind with flexible wall alignment, horizontal adjustment facility complete all as specified and directed: Blanking (1module)\nMake: Legrand Arteor Cat-Part No. 5734 49 /Hager (Berker)/Schneider(Zencelo) | | 279 | Each |
|---|
| 25 | 25 | S&F 20W surface/Wall mounted LED Luminaire , with high efficiency long life LED chips, CRI=80(Minimum) PF>.95, System luminous efficacy >100, Operating voltage 140V-270V including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to LED fitting Complete all as spd and directed. Make: Baja Cat No BLTRU 20W NW VIVA/ Philips Cat No BN 308C-LED-2220S-6500/ Osram cat No Luxpower Batten 19WL840. | | 692 | Each |
|---|
| 26 | 26 | S&F 10/12W surface mounted round shape LED downlight with minimum efficiency 85 lumen/W, high qualitypoly carbonate opal concave diffuser, high reflective polycarbonate conical shape reflector, input voltage 220-240V, input frequency 50-60Hz including electric connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to fixture complete all as spd and directed. Make: Wipro Cat No LW01-101-xxx-60xx/ GE cat No 93057384/ Bajaj Cat No BGCML12WWH | | 432 | Each |
|---|
| 27 | 27 | S&F LED street lights, 25 W, lumen output not less than 2500 lm high pressure die cast aluminum housing, 140-270V, 50 Hz, PF>0.90, including 1.2 mtr long 40 mm bore light grade GI pipe mounting bracket made to shape with and including MS clamps of FI 40mmX 6mm with bolts, nuts, washers and conductor to fitting with 3 core 1 sqmm PVC insulated copper cable from control box to fitting complete all as spd. Note: The quoted unit rate deemed include for painting to clamps with one coat of redoxide paint before fixing. Complete all as spd and directed by Engineer-in-Charge.Make:- Wipro (skyline LED)/Halonix (LUMOS-MINF) | | 86 | Each |
|---|
| 28 | 28 | S & F BEE five star rated energy efficient high-speed ceiling fan having 1200 mm sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed.\nMake: Havells Cat- Part No. ES-50 or Crompton Cat-Part No. ENTRUST50 or equivalent model of Usha (Nabila)/Orient (Ecotech) | | 308 | Each |
|---|
| 29 | 29 | S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 800 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed.\nMake: Crompton Cat-Part No.VENTILUS 10\" or equivalent model of Usha, Havells or BAJAJ | | 166 | Each |
|---|
| 30 | 30 | S & F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 19 CMM at 900 RPM operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the exhaust fan complete all as specified and directed.Make: Crompton Cat-Part No.TRANS AIR 12\" or equivalent modelof Usha/Havells or Orient | | 83 | Each |
|---|
| 31 | 31 | S & F lSI marked MCB for AC applications till 63 A, having breaking capacity lcn= 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed.\nMake: Schneider, Legrand,Hager/Siemens | | | |
|---|
| 32 | 32 | 6A, SP MCB, C- curve | | 422 | Each |
|---|
| 33 | 33 | 16A, SP MCB, C- curve | | 250 | Each |
|---|
| 34 | 34 | 20A, SP MCB, C- curve | | 101 | Each |
|---|
| 35 | 35 | 32A, SP MCB, C- curve | | 65 | Each |
|---|
| 36 | 36 | 80A, TP MCB, C-curve | | 12 | Each |
|---|
| 37 | 37 | 63A, FP MCB, C-curve | | 9 | Each |
|---|
| 38 | 38 | M&L for solid annealed tinned copper conductor PVC sheathed of size 0.4mm for telephone wiring from terminal box to telephone socket complete all as specified and directed (conduit and accessories shall be measured and paid separately) Make : KEI/RR Kabel/Havells | | 906 | RM |
|---|
| 39 | 39 | M&L for wiring TV coaxial RG-6 solid annealed bare copper conductor of nominal dia of 7mm polyethylene insulated shielded with polyester backed aluminium tape for TV antenna from terminal box to TV socket complete all as specified (Note : Conduit pipe and fittings shall be measured and paid separately) Make :\nRR Kabel/KEI/Havells | | 770 | RM |
|---|
| 40 | 40 | S&F single phase static energy meter of accuracy class 1.0, 240V, 50Hz with backlit LCD, Optical port & RS 232 port display of rating 10-60A with DLMS compliance as per IS 15959(Measures Kwh, KVAh,V,I,PF, Frequency, KW,KVA, six month history of energy & MD in KW & KVA and anti temper features and load profile complete all as spd and directed. Make: HPL/L&T/Secure | | 78 | Each |
|---|
| 41 | 41 | S&F Three phase static energy meter of accuracy class 1.0, 240V, 50Hz with backlit LCD, Optical port & RS 232 port display of rating 10-60A with DLMS compliance as per IS 15959(Measures Kwh, KVAh,V,I,PF, Frequency, KW,KVA, six month history of energy & MD in KW & KVA and anti temper features and load profile complete all as spd and directed. Make: HPL/L&T/Secure | | 12 | Each |
|---|
| 42 | 42 | Supply and erection of vertical double door sheet enclosure distribution board (IP 43) suitable for MCCB as incomer recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in charge | | | |
|---|
| 43 | 42.01 | 6 way, TPN (Vertical DB with MCCB provision as incomer and provision for 4 Nos. 63A MCB TP and 1No. MCB SP as outgoings). Legrand make Cat No. 5077 46 or Schenider. [Cost of MCCB and MCBs not included in this item and are taken separately]. | | 4 | Each |
|---|
| 44 | 42.02 | 4 way, TPN (Vertical DB with MCCB provision as incomer and provision for 2 Nos. 63A MCB TP and 1No. MCB SP as outgoings). Legrand make Cat No. 5077 46 or Schenider. [Cost of MCCB and MCBs not included in this item and are taken separately]. | | 2 | Each |
|---|
| 45 | 43 | SEWAGE DISPOSAL\nConstruction of Septic tank package type for 50 users all including excavation in any type of soil PCC in foundation,PCC solid block masonry, RCC precast cover slabs, inlet and out let chambers, vent pipe and cowl, precast manhole cover with MS frame all round, vent shaft etc complete all as shown on Drgs.(TD/289 | | 2 | Each |
|---|
| 46 | 44 | Construction of Septic tank package type for 25 users all including excavation in any type of soil PCC in foundation,PCC solid block masonry, RCC precast cover slabs, inlet and out let chambers, vent pipe and cowl, precast manhole cover with with MS frame all round, vent shaft etc complete all as shown on Drgs.(TD/79) | | 4 | Each |
|---|
| 47 | 45 | Construction of Soakage pit of size 2.40m dia and 3.0meffective depth with excavation in any type of soil, honeycombed wall below, brick bat filling, block masonry on top with RCC precast slab, wall plaster all as shown on Drgs(TD/365) | | 2 | Each |
|---|
| 48 | 46 | EXTERNAL WATER SUPPLY\nSupply, testing and commissioning of centrifugal pump set of discharge capacity 900 LPM at 40 mtr head, Split casing type,80x80mm suction/dischargeand coupled with suitable rating induction motor 3 phase 415 volts, 50 Hz, mounted on MS chanel/common base plate and fixed with suitable bolts, grouted in PCC foundation , 30 CM above floor level including PVC insulated single core unsheathed copper conductor of 06 sqmm size drawn in PVC conduit for connection from starter to motor terminal, including the following accessories. (i)Foot valve - 01 No of size suitable for suction of pump. (ii) flanged GI Medium grade suction pipe of dia as spd by manufacturer to a length not more than 9 m. (iii) Delivery pipes GI mediumgrade of dia as spd by manufacturer to a length not more than 6m. (iv) pressure gauge on delivery of pump ser. (v) Interconnection of delivery mains of pump I and II. (vi) 20mm GI pipe line for priming. (vii) 20mm Gun Metal Gate valve (priming valve) - 01 Nos.\n | | 2 | Each |
|---|
| 49 | 47 | Supply, laying and jointing of DI Pipe flanged end Class K-9 including flanges as jointing material with internal cement mortar coating and external surface with bituminous paint of size 80mm for suction and delivery connection of pump set complete all as specified and directed. | | 25 | RM |
|---|
| 50 | 48 | Supply, laying and jointing of DI Pipe flanged end Class K-9 including flanges as jointing material with internal cement mortar coating and external surface with bituminous paint of size 200mm complete all as specified and directed | | 50 | RM |
|---|
| 51 | 49 | Supply, laying and jointing in trenches DI pipes class K9 of standard length spigot and socketed end push type joint with and including push on rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 150 mm dia ISI all as spd and directed. | | 150 | RM |
|---|
| 52 | 50 | Supply, laying and jointing in trenches DI pipes class K7 of standard length spigot and socketed end push type joint with and including push on rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 150 mm dia ISI all as spd and directed. | | 490 | RM |
|---|
| 53 | 51 | Supply, laying and jointing in trenches DI pipes class K7 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 100 mm dia ISI all as spd and directed. | | 200 | RM |
|---|
| 54 | 52 | Supply, installation and testing of CI sluice valve 200mm dia flaned end class PN 1.0 as per IS 14846 heavy duy with stainless steel spindle and iron wheel at the top flanged ends including two Nos of flanged joint and jointing material ie nut bolts all as specified and directed . | | 2 | Each |
|---|
| 55 | 53 | Supply, installation and testing of CI sluice valves 150 mm dia flanged end class - I PN 1.0 as per IS 14846 heavy duty with stainless steel spindle and iron wheel at the top flanged end incl two Nos of flange joint incl jointing materials ie bolts and nuts all as directed. \nMake:L&T/Kirloskar/Zoloto/Kesin | | 8 | Each |
|---|
| 56 | 54 | Supply, installation and testing of CI sluice valves 100 mm dia flanged end class - I PN 1.0 as per IS 14846 heavy duty with stainless steel spindle and iron wheel at the top flanged end incl two Nos of flange joint incl jointing materials ie bolts and nuts all as directed. \nMake:L&T/Kirloskar/Zoloto/Kesin | | 2 | Each |
|---|
| 57 | 55 | Supply, installation and testing of CI sluice valves 80mm dia flanged end class - I PN 1.0 as per IS 14846 heavy duty with stainless steel spindle and iron wheel at the top flanged end incl two Nos of flange joint incl jointing materials ie bolts and nuts all as directed. make: Kirloskar/Zoloto/Kesin/L&T/Leader | | 4 | Each |
|---|
| 58 | 56 | M&L for valve reflux with by pass arrangement supplied and installed complete of size 80 mm dia bore. Make:Zoloto/Leader/Venus/L&T | | 2 | Each |
|---|
| 59 | 57 | Material and Labour for DI fittings and fixtures Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 200mm bore. | | 400 | Kg |
|---|
| 60 | 58 | Material and labour for construction of for Valve Pit /Chamber in PCC solid block masonry (1:5:8) built in CM 1:6 ,over 150 mm thick PCC foundation 1:3:6 type C2, 10mm thick internal CM 1:6 & 12mm thick external plaster in CM 1:4 provided with 3 mm thick MS sheet cover and MS angle iron chamber frame fixed in coping in PCC 1:2:4 type B-1 with locking arrangement and handle, painting of MS work with one coat of red oxide primer and two coat of synthetic enamel black paint complete including excavation & earth work in any type of strata complete all as shown on drawing No.CEAA/TD/57sheet No 1.1,dated 28.05.92,amended upto 31.12.92, but of internal size 1050mm(L) x 750mm(B) x 1000mm (D) etc complete all as specified and directed.Note : Excavation Retuning filling is including in the item | | 2 | Each |
|---|
| 61 | 59 | M & L for LT panel Board cubical KIOSK Indoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated from Polycarbonate, Nominal Size 900mm X600mmX 660mm, RAL 7035 finish confirming to IP 54 complete including Cu bus bar 100 Amps, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following: (Make of Panel : Hensel/ Neptune/Universal L&T/ and Make of MCCB/MCB : Hager/Legrand/Schneider ) (a) Incoming MCCB 40 Amps 4 pole with microprocessor based release having breaking capacity 36 KA.....01 Nos. (b) Outgoing MCB 32 Amps 415 V, Triple Pole, 36KA---02 Nos. \n(c) Outgoing Star Delta starter of appropriate capacity of pump set catered vide item no. 49.00 … 02 Nos \n(d) Digital Voltmeter 0-500 V 96x96xm …. 01 No \n(e) Digital Ammeter 0 - 500 A 96x96m …. 01 No \n(f) Indicating lamps set RYB …. 01 set. \n(g) Panel mounted type digital multifunctional energy meter, CT operated, LT 3 phase, 4 wire, including CT ratio 200/5---01 No | | 1 | Each |
|---|
| 62 | 60 | Supply, Installation, testing of dosing pump, electric operated, single phase, cap 20 ltr/hr, PTFE coated EPDM diaphragm complete all as specified and directed. Make TOSHCON JESCO, Model- TJ-MD 20. or equivalent | | 1 | Each |
|---|
| 63 | 61 | Supply only calcium hypochlorite granules containing 65% free chlorine in 45 Kg container complete all as specified and directed | | 7 | Each Drum |
|---|
| 64 | 62 | EXTERNAL ELECTRIC SUPPLY\nM & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, Nominal Size 1100mmX1950mmX400mm, RAL 7035 finish confirming to IP 54 complete including Copper bus bar 400 Amps, 30 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- (Make: Make of Panel : Hensel/ L&T/ ABB/Neptune/Universal \nMake of MCCB/MCB : Hager/Legrand/Schneider) INCOMING :- \n(a) Incoming MCCB 160 Amps four pole with microprocessor based release, having breaking capacity 36 KA, ---01 No \nOUTGOING :- \n(b) Outgoing MCCB 100/63 Amps four pole with microprocessor based release, having breaking capacity 25 KA, ---04 No. \n(c) Digital Multifunctional panel meter for Amp, Volt,KWH, power factor and other parameter flush mounting of size 96 x96 mm all as spd and directed. (d) Platform for the feeder pillar board with pcc 1:2:4, type B1 using 20 mm graded stone aggregate 15 cm thick on foundation in cm 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 40 mm graded stone aggregate as in padding on top and grouting.The platform shall be of 450mm height above GL and of adequate size and having minimum 300 mm all around the feeder pillar board for movement. | | 1 | Each |
|---|
| 65 | 63 | M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, Nominal Size 1400mmX1950mmX400mm, RAL 7035 finish for stand confirming to IP 55 complete including Copper bus bar 400 Amps, 30 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- Location :FP-I, FP-II. (Make of Panel : Hensel/ L&T/ ABB /Neptune\n Make of MCCB/MCB : Hager/Legrand/Schneider)\n(a) Incoming MCCB 250 Amps four pole with microprocessor based release, having breaking capacity 36 KA, ---01 No . (b) Outgoing MCCB 100/63 Amps four pole with microprocessor based release, having breaking capacity 25 KA, ---06 No . (c) Digital Multifunctional panel meter for Amp, Volt,KWH, power factor and other parameter flush mounting of size 96 x96 mm all as spd and directed. (d ) Platform for the feeder pillar board with pcc 1:2:4, type b1 using 20 mm graded stone aggregate 15 mm thick in cm 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 40 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The platform shall be of 450mm height above GL and of adequate size and having minimum 300 mm all around the feeder pillar board for movement | | 2 | Each |
|---|
| 66 | 64 | S&F Air Break switch having polymeric insulator, single break, tilting type, vertical mounting comprises of hot dip galvanized channel iron base having 3 Nos 11KV rate current 200A with operating mechanism worked from GL for isolation of Transformer. Make: RPG/Pactil/Atlas | | 2 | Each |
|---|
| 67 | 65 | S&F Pin type polymeric insulator confirming to IEC, 11KV, 5KN with galvanized fixing arrangement all as spd and directed. Make: Raychem RPG/Pactil/Atlas | | 3 | Each |
|---|
| 68 | 66 | S&F Ball and socket type polymeric insulator, 11KV, 45KN confirming to IEC completes all as spd and directed. Make: Raychem RPG/Pactil/Atlas | | 3 | Each |
|---|
| 69 | 67 | Supply & fix 11KV drop out fuse single pole with insulators,barrel and suitable rating of fuse element as per site requirement complete all as specified and directed. | | 2 | Each |
|---|
| 70 | 68 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size 90 mm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Gemini. | | 920 | RM |
|---|
| 71 | 69 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size 63 mm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Gemini. | | 360 | RM |
|---|
| 72 | 70 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size 110 mm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Gemini. | | 260 | RM |
|---|
| 73 | 71 | Supply & fix cable route indicator made out of 40mm x 40mm x4mm mild steel angle iron 1 metre long and mild steel plate of size 100mm x 150mm x 6mm welded only on one side and having embosed on plate as cable HT including PCC 1:2:4 type B1 of size 30cmx30cmx30cm and embedding angle iron including excavation and earth work complete all as specified and directed. | | 40 | Each |
|---|
| 74 | 72 | Supply & fix cable route indicator made out of 40mm x 40mm x 4mm mild steel angle iron 0.6 metre long and mild steel plate of size 75mm x 60mmx6mm welded only on one side and having embosed on plate as cable LT including PCC 1:2:4 type B- 1 of size 30cm x 30cm x 30cm and embedding angle iron including excavation and earth work complete all as specified and directed by Engineer - in - Charge. | | 150 | Each |
|---|
| 75 | 73 | Supply, installation, testing and commissioning 3 phase and neutral, 415 volts factory made free standing, floor mounting, dust and vermin proof cubical type, LT panel fabricated from 3.0 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of busbars made of high conductivity 99.9% pure copper of ETP grade suitable for 1000 amps pre-wired with suitable size of copper strip, short circuit rating 50 KA (rms) for one second including suitable aluminium earth strips conforming to IS and all as specified with supply and suitable to accommodate and fixing the following:- \n (NCOMING ?i) MCCB 630 amps 4 pole with breaking capacity 50 KA - 01 No (ii) Digital Multifunctional Panel meter of size 96X96 mm and three current transformer of suitable ratio and capacity. \nOUTGOING :- (i) MCCB 160 amps 4 pole ultimate breaking capacity 36 KA with electronic releases suitable for 415V complete with Rotary handle complete all as specified – 01 No\n(ii) MCCB 250 amps 4 pole ultimate breaking capacity 36 KA with electronic releases suitable for 415V complete with Rotary handle complete all as specified - 03 No\n(iii) MCCB 100 amps 4 pole ultimate breaking capacity 36 KA with electronic releases suitable for 415V complete with Rotary handle complete all as specified - 02 No\n Add Make of Panel : Hensel/ L&T/ ABB/Neptune \n Make of MCCB/MCB : Hager/Legrand/Schneider \n | | 1 | Each |
|---|
| 76 | 74 | Supply, installation ,testing and commissioning of LED Aviation light suitable for LED lamp 4-5 watt by means of base plate and GI Pipe with dash fastner, toughened heat resistant glass neoprene complete all as specified and directed. Make: Bajaj Cat No.BGAV 302 LED or its equivalent in Crompton/Philips . | | 1 | Each |
|---|
| 77 | 75 | M & L for sub main wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors, and insulation conforming to IS 5831-1984 with phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 20 mm PVC heavy grade conduits, conforming to IS: 9537 (Part 3)- 1983, color-coded as specified in IS: 11353- 1985, complete all as specified and directed with cables 2.5 mm² size. Make: RR Kabel, Polycab, Havells \nNOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of conduit shall be measured as one length \n\n | | 40 | RM |
|---|
| 78 | 76 | STREET_LIGHT Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground calbes of size 63 mm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Gemini | | 50 | RM |
|---|
| 79 | 77 | Supply and fix octagonal hot-dip galvanized street light poles including junction box, height 7 mtrs, top dia 70mm, bottom dia 130 mm, sheet thickness 3 mm, base plate 220x220x12 ,foundation nut bolts as per manufacturer recommendation including reinforced cement concrete foundation and hot dip galvanised bracket single arm for fixing of street light and one no of MCB 6 amp including 25 Amp four way terminal block all as spd and directed. MAKE: BAJAJ/SURYA/PHILIPS/ CG | | 9 | Each |
|---|
| 80 | 78 | Supply & fix LED light, Nominal watt 35 Watt, Nominal lumen efficiancy 90 lumen/Watt, high pressure die cast aluminium housing, 140-270V, 50 Hz, PF>0.95 LED street light luminaries to be mounted on octagonal hot-dip galvanized street light poles including 3 core 1 sqmm PVC insulated copper cable from control box to fitting complete all as spd and as directed by Engr-in-Charge Make: Philips)/ Wipro(Skyline) /Osram(Strada plus) complete all as spd and directed | | 9 | Each |
|---|
| 81 | 79 | Supply,fix and testing Street Light Automatic nature switch for three phase load upto 5 KW using infrared sensor based Timer switch including the sensor having part night operation facility of minimum 04 hrs to maximum 12 hrs, the sensor alongwith 03 nos contactor each of 20-25A incoming MCB and outgoing MCBs of 20-25A (03 Nos) and auto manual (sensor bypass) size of circuit should be multistranded FRLS min size of 10sqmm wall mounted/pole mounted enclosure made of rust proof, electric shock proof Sintex made of SMC junction box confirming to IP 54 and model Swadeep 02 EC 5 KW 3P all as specified and directed. Make : Nature switch Kakatiya Energy system/Bajaj/Healer. Contactor : BCH/L&T/Schneider Wire for circuit wiring : Polycab/Finolex/Havells FRLS | | 1 | Each |
|---|
| 82 | 80 | TELEPHONE DB\nM&L for Double RJ11 Telephone Jacks 1 module with pressed steel sunken box Equipped with modular Jack connector with 1/4 turn terminal for fast connection all as spd and directed. | | 77 | Each |
|---|
| 83 | 81 | M&L for TV socket outlet, 1 module complete all as spd and directed. | | 77 | Each |
|---|
| 84 | 82 | M&L for 10 Pair Telecom Junction box withKrone frame all as spd and directed | | 15 | Each |
|---|
| 85 | 83 | M&L for 0.5mm 2 Pair Telephone cable PVC insulated copper conductor all as spd and directed | | 770 | RM |
|---|
| 86 | 84 | M&L for TV cable PVC insulated copper conductor all as spd and directed | | 770 | RM |
|---|