}

Konni Block Panchayathu - 2019-20 ( Project No . A2/41/2019 , Dated-3/6/2019 ) - Rwss To Thannithodu -Supplying And Installing Vt Pump Set And C/F Pump Set At Intake Pump House And Booster Pump House, Pathanamthitta District-Kerala

Kerala Water Authority has published Konni Block Panchayathu - 2019-20 ( Project No . A2/41/2019 , Dated-3/6/2019 ) - Rwss To Thannithodu -Supplying And Installing Vt Pump Set And C/F Pump Set At Intake Pump House And Booster Pump House. Submission Date for this Tender is 02-03-2020. Bolts Tenders in Pathanamthitta District Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

23594655
Corrigendum : Konni Block Panchayathu - 2019-20 ( Project No . A2/41/2019 , Dated-3/6/2019 ) - Rwss To Thannithodu -Supplying And Installing Vt Pump Set And C/F Pump Set At Intake Pump House And Booster Pump House
Tender
Indian
Kerala
Pathanamthitta District
02-03-2020

Tender Details

Konni Block Panchayathu - 2019-20 ( Project No . A2/41/2019 , Dated-3/6/2019 ) - Rwss To Thannithodu -Supplying And Installing Vt Pump Set And C/F Pump Set At Intake Pump House And Booster Pump House , Appendix - A -Supplying And Installing Of Vt Pump Set At Intake Pump House , Supply , Erection And Commissioning Of Brand New Vt Pump Set With The Following Specification . , Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Water Lubricated Vertical Turbine Pumpset With Bronze/Ss Impeller , Ss Shaft With Ms Erw Column Pipe Of Suitable Diameter And Length . The Pumpset Shall Be Suitable To Be Coupled With Vertical Hollow Shaft Motor . The Duty Condition Of Pumpset Are: Discharge - 340 Lpm , Total Head 140 Meter , Delivery Size So As To Suit The Existing Pumping Main . , Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make ( F . L . Speed Of Motor- 1400-1500 Rpm ) Screen Protected Drip Proof Squirrel Cage Vertical Hollow Shaft Induction Motor Suitable For Operation At 415 Volts 3 Phase 50 Hz . Ac Supply For The Above Pumpset . The Motor Should Confirm To Eefi/Is 325 . Supply Of Suitable Size Best Quality Isi Marked Pn 1 . 6 Heavy Duty Cast Iron Double Flanged Sluice Valve And Reflex Valve Suitable For The Above Pumpset . Fabricating And Connecting Delivery Pipe Of Required Size With Y- Connection And Necessary Joints Made Out Of Suitable Size Ms Pipe In Suitable Length With Required Flanged Joints And Seating On Supports As Per Site Condition . Supply Of Of The Motor Is Including Providing Suitable Concrete Foundation , Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors , Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , Panel Board ( Suitable For Operating Two Pump Sets But One Pumpset At A Time ) -Supply , Erection Testing And Commissioning Of Panel Board Consisting Of Suitable Capacity Tpn Swith With Hrc Fuse/ Mccb Voltmeter With Selector Switch , Ammeter With Selector Switch , Fitted With 3 Nos . Of Indicator Lamps With All Fittings As Per Ie Rules , Panel Board Shall Have Facilities And Capacity For Operating 2 Nos Of Motor Of Above Capacity And Should Have Necessary Interlocking Arrangements . The Panel Should Have Provision For Fixing Capacitor And Giving Electric Connection To All Equipments As Per Ie Rules And Code Of Practice . Conducting Satisfactory Trial Etc . Complete As Per The Direction Of Departmental Officers . The Panel Shall Be Fitted On A Common Base Frame On Suitable Foundation . , Cabling Work - Supply , Laying , Testing And Commissioning Of Suitable Size Xlpe Cables As Per Is Standards For The Above Pumpset From Panel Board To Starter And From Starter To To Motor Considering Energy Conservations , Earthing - Supply Of Al Materials And Providing Suitable Earthing By Using Suitable Size Pipe/Plate Earthing Gi/Copper Strip Buried In Ground And Giving Double Earthing To Motor , Starter , Panel Board Etc . As Per Ie Standards With Suitable Cable And Connecting The Same To The Earth Pit Provided As Per Is 3043/ 87 And Ie Rules . And Code Of Practice Etc . Complete , Capacitor - Supply , Erection Testing And Commissioning Of Heavy Duty App Capacitor For The Motor To Get A Power Factor Above 0 . 95 . The Capacitor Shall Confirm To Is 2834 , Valves - Supply Of Suitable Size Best Quality Heavy Duty Isi Marked Ci Double Flanged Sluice Valve With Pn 1 . 6 And Non Return Valve With Suitable Pressure Rating . Fitting Of Valves Shall Include Proper Rcc Support Especially For Non Return Valves . In Case Of Positive Suction Pump Set Sluice Valve Shuold Be In Suction As Well As Delivery Sides For Easy Repair Works . , Delivery Pipe Connection - Supply And Fitting Of Suitable Size Delivery Pipe Of Best Quality Ms Of Thickness Not Less Than 10Mm For Length Required At Site And Valves , Specials Etc . Complete And Connecting The Delivery Side Of The Pump With The Pumping Main . , Total Head = 140 M . Discharge = 340 Lpm . Rpm = 1400 -1500 Range . , Supply Of Ci Non Return Valve , Conforming To Is 5312 Part I - 1984 , Pn 1 . 6 , Size 80Mm . , Supply Of Ci Double Flanged Sluice Valve Conforming To Is 14846 - 2000 , Sluice Valve With Cap Pn 1 . 6 , Size 80Mm . , Providing And Fixing C . I . Sluice Valves ( With Cap ) Complete With Bolts , Nuts , Rubber Insertion Etc . ( The Tail Pieces If Required Will Be Paid Separately ) :150 Mm Diameter , Supply Of Ci Non Return Valve , Conforming To Is 5312 Part I - 1984 , Pn 1 . 0 , Size 150Mm . , Fabricating Interconnection Works Using 80 M . M Gi Pipe Up To A Length Of 12 M For Connecting Delivery Pipe Line Of Existing And Newly Erected Vt Pump Including The Cost Of Fixing Nr Valve-2 Nos And Sluice Valve 2 Nos , Cost Of Flanges , Flanges Joints , Fabricating Bends , Welding Charges And All Incidental Works Etc Complete As Per The Direction Of Departmental Officers . , Supplying 80 M . M Gi Pipe ( M ) , Appendix - B - Supplying And Installing C/F Pump Set At Booster Pump House , Supply , Erection And Commissioning Of Brand New Cf Pump Set With The Following Specification . , Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Centrifugal Pump Sets With Bronze/Ss Impeller , Ss Shaft And Ci Pump Casing With Suitable Type Base Plate With Coupling , Coupling Guard Foundation Bolts; Nuts Etc . Complete Suitable For Coupling The Pump And Motor Above The Plate Etc . Complete Including Providing Suitable Concrete Foundation Including Cost Of Cement , Sand And Metal Etc . Complete , Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Horizontal Solid Shaft Foot Mounted Tefc Squirrel Cage Induction Motor Suitable For The Above Pump Working 3 Phase 50 Hz Ac Supply , Working Voltage 415V . The Motor Shall Confirm To Eefi/Is 325 Including Providing Suitable Concrete Foundation Including Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors . , Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , Panel Board ( Suitable For Operating Two Pump Sets But One Pump Set At A Time ) ;Supply , Erection Testing And Commissioning Of Cubical Type Floor Mounted Ms Fabricated Dust And Vermin Proof Common Control Panel Board Consisting Of 1No . Suitable Capacity Mccb As Incomer And 2Nos . Suitable Capacity Mccb As Out Going ( The Two Mccbs Are Interlocking With Each Other ) Providing Suitable Size Aluminium Bus Bar Interconnect The Above Mccbs And Fitted With 3Nos . Of Indicator Lamps , 1No . Volt Meter With Selector Switch , 1No . Ammeter With Selector Switch Etc . Complete And Provided With A Common Earth Bus For The Entire Panel And Interconnect With The Mccbs As Per Ie Rules And Code Of Practice . The Panel Shall Be Fitted On A Common Base Frame On Suitable Foundation . , Cabling Work - Supply , Laying , Testing And Commissioning Of Suitable Size Xlpe Cables For The Above Pump Set From Panel Board To Starter And From Starter To Motor Considering Energy Conservations

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 22-02-2020 TenderExtn1 Date 02-03-2020

Key Value

Document Fees
INR 2800 /-
EMD
INR 26700.0 /-
Tender Value
INR 10.67 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail