Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-03-2020 | Date Extension2 | Date | 18-03-2020 |
| 2 | 22-02-2020 | Date Extension | Date | 11-03-2020 |
| Name of Work: Construction of 02 No’s Hostels (Boy’s & Girl’s) at New campus of LUVAS Hisar | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | CIVIL WORK - HSR ITEMS :- | |||
| 2 | 1.01 | Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres. (HSR 6.6) Note :- 98% SPD of the bottom surface will acheived. This compaction is incidental to work. \n2. Clearing grass and removal of the rubbish upto distance of outside the periphery of the area cleared is incidental to this item and nothing extra will be payable on clearing grass and removal of rubbish. | 7.74 | 100 CUM | |
| 3 | 1.02 | Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation , including disposal of all surplus soil as directed within a lead of 30 Mtrs.\n\nNote : Clearing grass and removal of the rubbish upto distance of outside the periphery of the area cleared is incidental to this item and nothing extra will be payable on clearing grass and removal of rubbish. | 17775.4 | cum | |
| 4 | 1.03 | Making holes by cutting cores of appropriate dia in RCC floor and roof of thickness upto 6\" (six inches) for passing drain pipe 4\" (four inches) internal diametre and repairing the hole after insertion of drain pipe etc. including finishing complete so as to make it leak proof | 920 | each | |
| 5 | 1.04 | Centring and shuttering for flat surfaces such as suspended floors, Roofs, landings, chhajjas, shelves etc. inclination not exceeding 25 degree with horizontal (HSR-9.1+ Note ii a) (A) First Storey | 5845.4 | Sqm | |
| 6 | 1.05 | 2ND Storey | 5419.42 | Sqm | |
| 7 | 1.06 | 3RD storey | 3988.47 | Sqm | |
| 8 | 1.07 | 4TH storey | 3658.91 | Sqm | |
| 9 | 1.08 | 5TH storey | 3658.91 | Sqm | |
| 10 | 1.09 | 6 TH Storey | 1357.16 | Sqm | |
| 11 | 1.1 | Centring and shuttering for faces of walls, partitions, retaining walls, well steining and the like (vertical or battering) including attached pilasters, buttresses etc. (HSR-9.5+ Note II a) (A) First Storey | 938.84 | Sqm | |
| 12 | 1.11 | Second Storey | 443.44 | Sqm | |
| 13 | 1.12 | Third storey | 443.44 | Sqm | |
| 14 | 1.13 | Fourth storey | 443.44 | Sqm | |
| 15 | 1.14 | Fifth storey | 443.44 | Sqm | |
| 16 | 1.15 | Sixth storey | 218.27 | Sqm | |
| 17 | 1.16 | Centring and shuttering for sides and soffits of beams hunchings, girders, bressumers and lintels. (HSR 9.7 + Note II a) (A) First Storey | 3952.64 | Sqm | |
| 18 | 1.17 | Second Storey | 2440.96 | Sqm | |
| 19 | 1.18 | Third storey | 2163.8 | Sqm | |
| 20 | 1.19 | Fourth storey | 2054.36 | Sqm | |
| 21 | 1.2 | Fifth storey | 2054.36 | Sqm | |
| 22 | 1.21 | Sixth Storey | 153.94 | Sqm | |
| 23 | 1.22 | Centring and shuttering for staircases with sloping soffits including risers and stringers. (HSR-9.8+ Note II a) (A) First Storey | 375.195 | Sqm | |
| 24 | 1.23 | Second Storey | 375.195 | Sqm | |
| 25 | 1.24 | Third storey | 255.08 | Sqm | |
| 26 | 1.25 | Fourth storey | 255.08 | Sqm | |
| 27 | 1.26 | Fifth storey | 255.08 | Sqm | |
| 28 | 1.27 | Centring and shuttering for Columns (square or rectangular or polygonal in plan). (HSR-9.9 + Note II a) (A) First Storey | 7417.53 | Sqm | |
| 29 | 1.28 | Second Storey | 3065.43 | Sqm | |
| 30 | 1.29 | Third storey | 2626.86 | Sqm | |
| 31 | 1.3 | Fourth storey | 2467.38 | Sqm | |
| 32 | 1.31 | Fifth storey | 2467.38 | Sqm | |
| 33 | 1.32 | Sixth storey | 870.84 | Sqm | |
| 34 | 1.33 | Centring and shuttering for columsn (circular or curved in plan) | 178.04 | Sqm | |
| 35 | 1.34 | Centring and shuttering for corbel, parapets, fascias and other similar items, including edges. (Third storey ) | 792.84 | Sqm | |
| 36 | 1.35 | Sixth storey | 2137.91 | Sqm | |
| 37 | 1.36 | Shuttering for faces of concrete foundation and foundation beams (vertical or battering) (HSR 9.13) | 1320.34 | Sqm | |
| 38 | 1.37 | 10.28. Cement concrete 1 : 8 : 16 with stone aggregate 40 mm Nominal sie in foundation and plinth. | 651.9 | Cum | |
| 39 | 1.38 | Cement concrete 1 : 4 : 8 with stone aggregate 20 mm nominal size in foundation and plinth. \nNote:- Surface should be smooth like floor so that water proofing treatment may be carried out easily. \nPlaster will not be allowed and if required due to weaviness, No payment will be allowed. (HSR 10.38 + Note e(ii)) | 1022.57 | Cum | |
| 40 | 1.39 | Cement concrete 1; 2 ; 4 with stone aggregate 20 mm nominal size in foundation and plinth.( HSR 10.41) | 478.05 | cum | |
| 41 | 1.4 | Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects. | 57.46 | CUM | |
| 42 | 1.41 | Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforcement cement concrete work,using cement content as per approved design mix ,including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement,including admixtures in recommended proportions as per IS 9103 to accerlerate ,retard setting of concrete, improve workability without impairing strenght and durability as per direction of Engineer-in-charge in foundation and plinth ( note : cement content considered in this item is @350 kg/cum) Note:-In case cement content of the design mix is more than the specified in above items ,nothing extra will be paid for extra cement to be consumed. In case cement content of the design Mix is less than the specified in above items, then less cement used as per design mix is recoverable separtely as per base rates. | 6153.32 | Cum | |
| 43 | 1.42 | Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforcement cement concrete work,using cement content as per approved design mix ,including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement,including admixtures in recommended proportions as per IS 9103 to accerlerate ,retard setting of concrete, improve workability without impairing strenght and durability as per direction of Engineer-in-charge infirst storey up to 4 metres above plinth level. ( Note : cement content considered in this item is @350 kg/cum) Note:-In case cement content of the design mix is more than the specified in above items ,nothing extra will be paid for extra cement to be consumed. In case cement content of the design Mix is less than the specified in above items, then less cement used as per design mix is recoverable separtely as per base rates. | 1992.55 | Cum | |
| 44 | 1.43 | Second Storey ( 823+2.55=825.55) | 1776.51 | Cum | |
| 45 | 1.44 | Third storey (825.55+2.55=828.10) | 1128.18 | Cum | |
| 46 | 1.45 | Fourth storey (828.10+2.55=830.65) | 927.36 | Cum | |
| 47 | 1.46 | Fifth storey (830.65+2.55=833.20) | 927.36 | Cum | |
| 48 | 1.47 | Sixth storey (833.20+2.55=835.75) | 417.81 | cum | |
| 49 | 1.48 | Providing and laying 80 mm thick ISI marked internlocking paver blocks conforming to IS 15658:2006 /IRC:SP:63-2004 of all Shapes and colours in design mix cement M-40 over a bed of 30 mm thick fine sand complete in all respect. (HSR 10.158). \n(Note:- Reputed make Paver Block Only ISI marked will be used as approved by Engineer-in-charge). Make : Unistone, Pavit, NTC | 573.24 | SQM | |
| 50 | 1.49 | Factory manufactured Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in Kerbs and the like items, indluding from work, placing and fixing in position, complete at the ground level.\n | 6.82 | Cum | |
| 51 | 1.5 | Factory manufacture Pre-cast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in tiles and channel ( SAUCER TYPE ) and the like items, indluding from work, placing and fixing in position, complete at the ground level. | 7.38 | Cum | |
| 52 | 1.51 | First class brick work laid in cement sand mortar 1:4 in foundation and plinth.(HSR 11.4) | 1014.63 | Cum | |
| 53 | 1.52 | 11.43 cm thick brick wall with every, fourth course, reinforced with hoop-iron, laid in 1:4 cement sand mortar in super structure. (HSR11.46+ Note IV a ) 1st storey | 646.52 | Sqm | |
| 54 | 1.53 | Second Storey | 654.97 | Sqm | |
| 55 | 1.54 | Third storey | 444.57 | Sqm | |
| 56 | 1.55 | Fourth storey | 444.57 | Sqm | |
| 57 | 1.56 | Fifth storey | 444.57 | Sqm | |
| 58 | 1.57 | 11.43 cm thick brick wall laid in cement sand mortar 1:4 without reinforcment in Foundation and plinth. (HSR-11.47) | 1320.44 | Sqm | |
| 59 | 1.58 | Masonry work using flyash - lime based bricks (IS:12894-2002) laid in cement sand mortar 1:6 in super structure.\n(a) 1st Storey | 2676.83 | Cum | |
| 60 | 1.59 | Second Storey | 1575.86 | Cum | |
| 61 | 1.6 | Third storey | 1197.89 | Cum | |
| 62 | 1.61 | Fourth storey | 1159.87 | Cum | |
| 63 | 1.62 | Fifth storey | 1159.87 | Cum | |
| 64 | 1.63 | Sixth Storey | 96.85 | Cum | |
| 65 | 1.64 | Corrugated G.I sheet roofing 0.80 mm thick fixed with galvanized iron ‘J’ or ‘L’ hooks, 10 mm dia G.I limpet and bitumen washers complete, excluding the cost of purlins,rafters and trusses. (HSR 13.18. | 744.4 | Sqm | |
| 66 | 1.65 | Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13.50) | 103 | Each | |
| 67 | 1.66 | Bottom Khurra on ground 1.2 m x 0.6 m consisting of brick-on-edge laid in cement mortar 1:3 over 75 mm cement concrete 1:8:16 including 12 mm thick cement plaster 1:3 (HSR 13.57) | 103 | Each | |
| 68 | 1.67 | Providing & fixing PVC Rain water pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (A) 100 mm dia PVC pipe 6 kg. pressure, Supreme, Finolex, Prince (HSR 13.89 (a) | 92.28 | Rmt | |
| 69 | 1.68 | Providing & fixing PVC Rain water pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (B) 150 mm dia PVC pipe pressure, Supreme, Finolex, Prince (HSR 13.89b) | 686.16 | Rmt | |
| 70 | 1.69 | Providing and fixing PVC Bend ISI mark. 100 mm dia PVC Bend Supreme, Finolex, Prince (HSR 13.90 (a) | 42 | Each | |
| 71 | 1.7 | Providing and fixing PVC Bend ISI mark. 150 mm dia PVC Bend Supreme, Finolex, Prince (HSR 13.90 (b) | 124 | Each | |
| 72 | 1.71 | Providing and fixing False Ceiling with 12 mm thick Gympsum Board fixed on M.S Steel runners frame ilc cost of screws angles, cleats, rawel plugs, with taping, filling with Gypsum compound and applying priming coat. etc. complete in all respects. \n | 617 | SQM | |
| 73 | 1.72 | Terracing consisting of 19 mm thick heat resistant tiles for roof insulation ,300 mm x 300 mm laid on 20 mm thick 1:3 cement coarse sand mortor including grouting with neat white cement over average 75 mm thick screed of 1:8:16 including two coats of bitumen laid hot at 1.65 Kg per sqm on top of RCC slab & cleaning of top surface complete .the tiles shall be made of white cement blended with fibrous polymer having flextural stress value of = 150 Kg/Cm 2 & thermal conductivity value = 0.18 w/m.k(Note :- No extra rate for rubbing will be paid. Contractor should quote the rate accordingly.. | 5555.03 | Sqm | |
| 74 | 1.73 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation,and backed with a black Glass fiber acoustical fleece. (GridSquare,Armstrong,Hunterdouglas) | 3392.57 | Sqm | |
| 75 | 1.74 | Screed of 50 mm of thick cement concrete 1:8:16 to be laid below the topping (HSR 14.4) + Note i 2nd storey | 4636.58 | Sqm | |
| 76 | 1.75 | Third storey | 3265.42 | Sqm | |
| 77 | 1.76 | Fourth storey | 3120.81 | Sqm | |
| 78 | 1.77 | Fifth storey | 3120.81 | Sqm | |
| 79 | 1.78 | Sixth storey | 276.27 | Sqm | |
| 80 | 1.79 | Conglomerate floor 40 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling | 1021.63 | Sqm | |
| 81 | 1.8 | 1st class spotless uniform color Kotah stone Flooring (RAATIA Varity) , minimum 25mm thick, in any pattern as specified over 20 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including single piece used in staircase and minimum 550x550mm in flooring, Granite rubbing and polishing.\n(Note :- No extra rate for granite rubbing will be paid. Contractor should quote the rate accordingly.) (HSR 14.62) 1st storey\n | 2875.31 | Sqm | |
| 82 | 1.81 | Second Storey (201.95+0.30=202.25) | 1846.45 | Sqm | |
| 83 | 1.82 | Third Storey (202.25+.3)=202.55 | 1500.54 | Sqm | |
| 84 | 1.83 | Fouth Storey | 1374.98 | Sqm | |
| 85 | 1.84 | Fifth Storey | 1374.98 | Sqm | |
| 86 | 1.85 | Sixth Storey | 186.17 | Sqm | |
| 87 | 1.86 | Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including single piece used in staircase and in flooring, Granite rubbing and polishing.\n(Note :- No extra rate for granite rubbing will be paid. Contractor should quote the rate accordingly.) (HSR 14.66) 1st storey\n | 41.43 | Sqm | |
| 88 | 1.87 | Second Storey (237+0.30=237.30) | 28.3 | Sqm | |
| 89 | 1.88 | Third Storey | 11.27 | Sqm | |
| 90 | 1.89 | Fouth Storey | 11.27 | Sqm | |
| 91 | 1.9 | Fifth Storey | 11.27 | Sqm | |
| 92 | 1.91 | P.V.C sheet flexible type conforming to I.S 3462-1966 flooring plain coloured marble or mottled finish on a smooth damp proof base laid with adhesive recommended by manufacturere including pressing the sheet with a suitable tool to get a smooth surface all complete 3MM THICK (Make LG) | 244.98 | Sqm | |
| 93 | 1.92 | Providing and fixing glass strips 4mm thick 40 mm wide in floors. (HSR 14.80). | 780.8 | Sqm | |
| 94 | 1.93 | Providing edge moulding to 17-20 mm thick Granite counters, Vanities, treads of stair case etc., including Machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-Charge.labour (Moulding) Double Moulding | 1126.59 | metre | |
| 95 | 1.94 | 12mm thick cement plaster on walls (1:6). \n(a) First Storey | 5038.43 | Sqm | |
| 96 | 1.95 | 2ND Storey | 4547.04 | Sqm | |
| 97 | 1.96 | 3RD storey | 3442.2 | Sqm | |
| 98 | 1.97 | 4TH storey | 3319.59 | Sqm | |
| 99 | 1.98 | 5TH storey | 3319.59 | Sqm | |
| 100 | 1.99 | 6th storey | 412.88 | Sqm | |
| 101 | 2 | 15mm Thick Cement Plaster 1:6 on the rough side of single or half brick wall.\n(a)First Storey | 9871.26 | Sqm | |
| 102 | 2.01 | 2ND Storey | 7924.91 | Sqm | |
| 103 | 2.02 | 3RD storey | 6838.06 | Sqm | |
| 104 | 2.03 | 4TH storey | 5882.47 | Sqm | |
| 105 | 2.04 | 5TH storey | 5882.47 | Sqm | |
| 106 | 2.05 | 6th storey | 2935.9 | Sqm | |
| 107 | 2.06 | Cement pointing 1:3 deep variety on brick and Tile work | 2701.73 | Sqm | |
| 108 | 2.07 | Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 16.1) | 3781.56 | Sqm | |
| 109 | 2.08 | Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc.(HSR-16.2) | 3781.56 | Sqm | |
| 110 | 2.09 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade.(HSR-16.3) | 7126.89 | Sqm | |
| 111 | 2.1 | Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces. | 29233.9 | Sqm | |
| 112 | 2.11 | White Washing :Three coats | 3957.93 | Sqm | |
| 113 | 2.12 | Distempering with washable oil bound Distemper two coats over one primer coat on new work. | 50793.5 | Sqm | |
| 114 | 2.13 | Providing two coats of exterior acrylic emulsion paint. 1st quality (HSR 16.79 b) | 29233.9 | Sqm | |
| 115 | 2.14 | Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete (J.K./Birla make)\nNote: Surface after birla putty should be smooth. In case, there is any variation in surface, contractor will apply another 02 coats without any extra cost to make the surface smooth.\n2. It will not be applied where false ceiling is to be done. In case of roof with false ceiling, white wash 03 coat will be applied and accordingly as per HSR will be paid. | 50331.1 | Sqm | |
| 116 | 2.15 | Providing & fixing six-levers brass 10 cm mortice latch and lock, and a pair of lever handles with necessary screws, etc. complete (Indian make of reputed firm, such as godrej, Diana/stella or equivalent) (HSR 17.73) | 68 | Each | |
| 117 | 2.16 | Factory manufactured panelled door or glazed windows shutters of commercial hard wood such as Hollock, Champ, Lal Marndi only. (non coniferous timber other teak, confirming to I.S. pecificationNo. 1003, Kiln seasoned) with 100mm wide vertical styles, 150mm wide lock rail 200 mm wide bottom rail, and 100mm wide other rails, with panels of 15mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges, screw, chock/cleats, stops nails etc. complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position). (a) 30 mm thick. [HSR 17.90 (a) - Note 1 under 17.18]. | 1005.09 | Sqm | |
| 118 | 2.17 | Factory manufacture solid flush door and Shutters, with block board core as per I.S. No. 1659-1969 bonded with water poof type phenol formal dehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in positon includeing iron hinges, screws, chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)-commercial veneering with vertical grains or corss bands and face veneer on both sides commercial facing with laminated core and lipped edges:- 25 mm thick | 674.025 | Sqm | |
| 119 | 2.18 | Factory manufacture solid flush door and Shutters, with block board core as per I.S. No. 1659-1969 bonded with water poof type phenol formal dehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in positon includeing iron hinges, screws, chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)-commercial veneering with vertical grains or corss bands and face veneer on both sides commercial facing with laminated core and lipped edges:- 35 mm thick | 2068.48 | Sqm | |
| 120 | 2.19 | Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. | 1182.16 | Qtl. | |
| 121 | 2.2 | Supplying, hoisting and placing in position tubular trusses including runners, purlins, consisting of steel tubes conforming to I.S. specifications of tested quality duly welded with fillet welds 6 mm thick through-out including wind bracing. Open end of pipe sealed with 3 mm thick plate including the cost of nuts and bolts where bolts connections are specified at flange joints including one coat of ready mixed red oxide zink cromate primer of approved quality assembling and fixed in positon complete in all respect. | 1189.2 | Qtl. | |
| 122 | 2.21 | Steel Reinforement TMT bars Fe-500D EQR/ FE 500D grade or more for RCC work, where not included in the complete rate of RCC including straightening , bending, binding, wastage,overlap,welded joints spacer bars , chairs,stays,hangers and annealed steel wire etc & placing in the position complete in all respects for all height /depth/storeys/ basement etc.\n( NOTE :- Reinforcment shall be measured in length including hooks, if any, separately for diferent diameters as actually used in work, excluding Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcment. ) | 16794.5 | Qtl. | |
| 123 | 2.22 | Supplying and fixing glass panes including special metal sash putty of approved makeglass panes 4 mm thick, exceeding 40 sq dm areas. (HSR 18.30 B) (On fixed portion only.) | 1610.75 | Sqm | |
| 124 | 2.23 | Extra for providing and fixing steel beading of approved shape and section with screws instead of glazing clips and metal sash putty - Window (HSR 18.31B) (On fixed portion only.) | 1610.75 | Sqm | |
| 125 | 2.24 | Pressed steel sheet frames (chowkats) consisting of 2 mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D specifications, including bolts for fixing stops, lock notch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non-setting primer of approved quality fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:3:6 for lungs complete. (HSR-no. 18.34 a) (a) Door and window frame of size 89 mm x 50 mm with 30/40 mm wide single rebate Note:- in case any other size as per HSR is used, rate HSR will be paid. | 6342.54 | Rmt | |
| 126 | 2.25 | (b) door and window frame of size 76 mm X 38 mm with 35 mm wide single rebate HSR 18.34 (b) | 2125.5 | Rmt | |
| 127 | 2.26 | door and window frame of size 114 mm X 50 mm with 40 mm wide double rebate. (HSR 18.34 D) | 7023.77 | Rmt | |
| 128 | 2.27 | PUBLIC HEALTH WORK - HSR ITEMS | |||
| 129 | 2.28 | Excavation of trenches in streets, lanes or in open areas for storm sewer, sewers running by gravity and manholes to full depths as shown in drawings including shoring, timbering of poling boards, frame system type, dressing to correct sections and dimensions, according to templates and levels, dewatering, provision for diversion of traffic, cutting trees and bushes, etc. night signals profiles, pegs, sight rails, boning rods, crossing over trenches for access to the houses, watching fencing etc. fixing and maintenance of caution board refilling of trenches, watering of refill, in 15 cm layers ramming and restoration of unmetalled or unpaved surface to original condition and removal of surplus soil, from site of work, upto a lead of 1 Km in oridnary soil. (a) for depths excavation not exceeding 3 metres below ground level. [HSR 6.10 (a)]. | 1097.37 | Cum | |
| 130 | 2.29 | Cement concrete 1:8:16 with stone aggregate 40mm nominal size in foundation and plinth. (HSR 10.28). | 202.72 | Cum | |
| 131 | 2.3 | Cement Concrete 1:2:4 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.41). | 27.9662 | Cum | |
| 132 | 2.31 | Drilling and Tapping cast iron pipe lines of all diameters and screwing in ferrule and connections-Size of ferrule. [HSR 28.22].(F) 40 mm internal diameter of pipeline. | 6 | Each | |
| 133 | 2.32 | Cutting holes upto 23 cm square through brick work in mud walls for pipes and making good including repointing replastering and finishing according to existing finish where required. (a) 11.43 cm thickness of walls | 280 | Each | |
| 134 | 2.33 | (b) 22.86 cm thickness of walls | 387 | Each | |
| 135 | 2.34 | Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside building including cartage from divisional stores or nearest railway station to site of works. (HSR 28.29). Only Labour part.(a) 15 mm internal diameter | 124 | Each | |
| 136 | 2.35 | (b) 20 mm internal diameter | 122 | Each | |
| 137 | 2.36 | (c) 25 mm internal diameter | 50 | Each | |
| 138 | 2.37 | (d) 32 mm internal diameter | 30 | Each | |
| 139 | 2.38 | (e) 40 mm internal diameter | 20 | Each | |
| 140 | 2.39 | Supply of Gun Metal Peet Valves. Only Material Part (N.S.) | |||
| 141 | 2.4 | (a) 15 mm internal diameter | 124 | Each | |
| 142 | 2.41 | (b) 20 mm internal diameter | 122 | Each | |
| 143 | 2.42 | (c) 25 mm internal diameter | 50 | Each | |
| 144 | 2.43 | (d) 32 mm internal diameter | 30 | Each | |
| 145 | 2.44 | (e) 40 mm internal diameter | 20 | Each | |
| 146 | 2.45 | Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-In-charge. [HSR 28.47 (a)].Upto 200 mm internal diameter | 6 | Each | |
| 147 | 2.46 | Constructing brick masonry inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent limer mortar 2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2;4 slab 100 mm thick./C.C. topping 50 mm thick with 455 mm x 455 mm 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint coplete as per standard design. [HSR 29.84].(a) Size 450 mm x 450 mm | 54 | Each | |
| 148 | 2.47 | (b) Size 450 mm x 600 mm | 30 | Each | |
| 149 | 2.48 | (c) Size 600 mm x 900 mm | 34 | Each | |
| 150 | 2.49 | Constructing brick masonry road gully chamber as per standard drawings (as per sizes given below) including dressing of beds and sides of chamber to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item no 10.6) in foundation, Ist class brick work laid in cement sand mortar, 1:5, 40mm thick cement concrete 1:2:4, topping inside the chamber with a floating coat of 1.5 mm thick neat cement laid in one operation to the topping the entire inner surface of the chamber rendered with neat cement not less than 12 mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1 mm thickleft absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as specified in item no. 29.48 complete and to the requirement of the Engineer-In-charge). (a) Single Road Gully Chamber (i) Size 610 mm x 457 mm x 800 mm. [HSR 29.87 (a) (i)]. | 52 | Each | |
| 151 | 2.5 | CONSTRUCTION OF RECTANGULAR STANDARD BRICK MASONRY MANHOLE CHAMBERS to standard drawings on S.W pipe sewers or other circular pipe sewers upto the required depth in 1.5 CEMENT SAND MORTAR, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium solicate on interior surface where required, reinforced cement concrete slab 180 mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. \nThe rate cover the cost of M.S steel for R.C.C slab Labour for fixing and carriage of C.I manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works.\nThe rate also includes the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. Sodium silicate shall be supplied free of cost at the stores of Engineer- in-charge. [HSR 29.90 (ii)].(ii) On 150 mm I/d Pipe sewer (a) For 1.20 Mtrs. depth below ground level | 22 | Each | |
| 152 | 2.51 | (b) For 1.50 Mtrs. depth below ground level | 22 | Each | |
| 153 | 2.52 | (c) For 1.80 Mtrs. depth below ground level | 22 | Each | |
| 154 | 2.53 | Providing, lowering, laying, cutting (cut surface to be uniformity finished) jointing with rubber rings marked with IS:5382 and testing of SPIGOT AND SOCKETTED RCC NP2 MARKED WITH IS:458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction to the Engineer -in-charge. (HSR 29.93).(c) 300 mm dia | 260 | Rmt | |
| 155 | 2.54 | (d) 350 mm dia | 762 | Rmt | |
| 156 | 2.55 | PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE FLAT BLACK OR ANGULAR LIPPED FRONT URINAL 465 MM HIGH consisting of:- (i) flat black lipped or angular urinal basin of VITREOUS CHINA WARE (to the approval Of the Engineer-in-charge)(i) White. [HSR 30.19 (i)]. | 106 | Each | |
| 157 | 2.56 | Providing & Fixing in position best indian make (ordinary) lavatory suites consisting of:- (v) Size 560 mm x 450 mm with one no. tap. [HSR 30.41(v)]. | 380 | Each | |
| 158 | 2.57 | PROVIDING AND FIXING IN POSITION 32 MM DIA G.I. WASTE PIPE EMBEDDED IN WALL or lead waste pipe (weighing 3.47 kg. per metre and 2.8 mm thick) upto floor Level including cost of wipped solder joint etc., complete (as required by the Engineer-in-charge). [HSR 30.48]. | 380 | Each | |
| 159 | 2.58 | Providing and fixing in position best Indian make chromium Plated brass Bottle trap 32 mm dia metre. complete (as required by the Engineer-in-charge). [HSR 30.50] | 380 | Each | |
| 160 | 2.59 | Providing and fixing in position best quality Stainless Steel Sinks with Complete fittings as fully described in item No. 30.51. (a) 600 mm x 450 mm x 200 mm. [HSR 30.53 (a)]. | 22 | Each | |
| 161 | 2.6 | Providing and fixing 40 mm I/D Stainless Steel waste pipe embedded in walls or lead waste pipe weighing 4.46 Kg./metre and 3.0 mm thick upto floor level as required by the Engineer-in-charge including cost of union and plumber joint. (HSR 30.62) | 22 | Each | |
| 162 | 2.61 | Providing and fixing 40 mm i/d chromium plated brass trap with chromium plated bra pipe to wall with wall flange, complete (as per requirement of the Engineer-in-charge) for use with sinks. (a) with Bottle Trap (indian make). [HSR 30.63 (a)]. | 24 | Each | |
| 163 | 2.62 | Providing and fixing in position best indian make shower with 125 or 20 I/D in-let. (d) C.P. brass with telephonic shower. [HSR 30.66 (d)]. | 210 | Each | |
| 164 | 2.63 | Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75].(a) Bib cock long body. | 536 | Each | |
| 165 | 2.64 | Providing & fixing in position C.P. brass stop cock (as approved by the engineer-in-charge). (a) 15 mm Stop cock. (ii) Concealed stop cock with flange. [HSR 30.76 (a) (ii)]. | 86 | Each | |
| 166 | 2.65 | Providing and fixing in position best Indian make flexible tube connection. (b) C.P. Brass (iii) 15mm x 450 mm. [HSR 30.82 (b) (iii)]. | 778 | Each | |
| 167 | 2.66 | Providing and fixing in position C.I. Gully trap cover weighing approximately 7.26 Kg. and frame for gully trap chamber clear opening size 300 mm x 300 mm and out side size 330 mm x 330 mm including painting the exposed surfaces with 3 coats of black bitumastic superior paint of approved manufacture etc. (HSR 30.85). | 90 | Each | |
| 168 | 2.67 | Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat not less than 5 mm of the approved design for fixing C.I. soil waste vent or anti pipes to walls complete in all respects. (a) for 100 mm interal diameter pipes. (HSR 30.88).(a) for 100 mm interal diameter pipes. | 55 | Each | |
| 169 | 2.68 | (b) for 75 mm interal diameter pipes. | 192 | Each | |
| 170 | 2.69 | Cutting chase in brick wall in cement or in floor for embedding G.I. or H.C.I. pipe lines and making good the same to its original condition. [HSR 30.95 (a)].(a) Size 75 mm x 75 mm. | 4764.12 | Rmt | |
| 171 | 2.7 | (d) Size 225 mm x 225 mm. | 1818 | Rmt | |
| 172 | 2.71 | Providing and fixing in position automatic brass ball valves in tanks. (b) With Plastic Ball (ii) 20 mm internal diameter. [HSR 30.110 (b) (ii)]. | 13 | Each | |
| 173 | 2.72 | Providing & Fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm x 150 mm cast iron cover weighing approximately 7.26 Kg. and frame clear opening 300 mm x 300 mm and outside size 330 mm x 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:2:4, in coping black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm. (b) 100 internal diameter H.C.I. gull trap. [HSR 30.114 (b)]. | 70 | Each | |
| 174 | 2.73 | Providing and fixing HDPE WATER STORAGE TANKS of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS: 12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction to the Engineer-in-Charge.(Except civil work) 500 litre | 5 | Each | |
| 175 | 2.74 | 2000 litre | 8 | Each | |
| 176 | 2.75 | Providing & fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on absetos sheet ground fixed in postion by means of 4 Nos. chromium plated brass screws and washers over rubbers washers and rawl plug embeded in the wall or chromium plated brass clamps with C.P. brass screws (as required by the engineer-in-charge) complete including cutting and making good the walls etc.\n(a) Indian Make \n(i) 600 mm x 450 mm. | 145 | Each | |
| 177 | 2.76 | ELECTRICAL WORKS - HSR ITEMS: | |||
| 178 | 2.77 | Main Switches Supply and erection of metal clad switches/ B.D.B.S with rag bolts on wall or on existing angle iron board/pedestal including bonding to earth and necessary connections:-Moulded case circuit breakers Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 100 Amp to 200 Amp.. 415 V , 10 KA 3-phase. | 2 | Each | |
| 179 | 2.78 | Supply and erection of miniature circuit breaker/isolator 240/415V in the existing distribution board including making necessary connections:-Miniature Circuit Breakers of 9 K.A. breaking capacity 6 amp. To 32 amp. | 1724 | Each | |
| 180 | 2.79 | 6 amp. To 32 amp. (S.P.N) | 12 | Each | |
| 181 | 2.8 | TPN MCB of 9 KA breaking capacity 40 Amp.. to 63 Amp.. | 112 | Each | |
| 182 | 2.81 | Call bell buzzer 220/230 volts A.C. bakelite with double coil | 5 | Each | |
| 183 | 2.82 | Supply and erection of Fittings and Accessories Bakelite angle/straight button holder Large size. | 10 | Each | |
| 184 | 2.83 | Supply and erection of hexagonal M.S box 1.60 mm thick having each side 8 cms 7.5 cms deep top covered with M.S lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable Suspension hook and erected in R.C.C slab for erection of fan, the bottom covered with 3 mm thick bakelite sheet with suitable holes, Painting etc. complete with all labour and material required to complete the job. | 990 | Each | |
| 185 | 2.84 | Supply and erection of PVC pipe of 6 kg. Pressure, laid 1 metre below ground level complete, including digging refilling of the trench with jointing etc:-PVC pipe 65 mm dia | 100 | Each | |
| 186 | 2.85 | Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required:-Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed. | 425 | Mtr. | |
| 187 | 2.86 | Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed. | 3425 | Mtr. | |
| 188 | 2.87 | Heavy guage welded conduit pipe 32 mm dia 1.60 mm thickness flushed. | 440 | Mtr. | |
| 189 | 2.88 | Supplying and laying of 8 S.W.G. G.I. wire at 0.50 metre below ground level as conductor earth electrode including thimbles, soldering etc. as required . | 100 | Mtr. | |
| 190 | 2.89 | Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. | 120 | Mtr. | |
| 191 | 2.9 | Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. | 120 | Mtr. | |
| 192 | 2.91 | Pdg. and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required . | 50 | Mtr. | |
| 193 | 2.92 | Supply and erection of 20 mm x 3 mm thick copper tape fixed with suitable copper staples of same size. | 120 | Mtr. | |
| 194 | 2.93 | Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . | 240 | Mtr. | |
| 195 | 2.94 | Excavation earth pit 180 cm round at top and 90 cm at bottom 4.5 metres deep and refilling the same in plains including supply of necessary charcoal/coke and salt mixture. | 8 | Each | |
| 196 | 2.95 | Supply and erection of 60 cm x 60 cm x 3 mm thick copper plate including fixing with necessary bolts and nuts to copper tape | 8 | Each | |
| 197 | 2.96 | Providing standard watering tank including down pipe and .CI. cover with locking arrangements etc. | 8 | Each | |
| 198 | 2.97 | Supply and erection of 20 mm x 3mm thick lighting conductor copper tape fixed with suitable copper stapples of same size. | 300 | Metre | |
| 199 | 2.98 | Supply and erection of copper tape 32 mm x 6mm thick from earth electrode directly in ground and surface, fixed with suitable copper stapples of same size. | 50 | Metre | |
| 200 | 2.99 | S&E of 25mm dia metre 1.5 metre long lighting solid copperrod tapped into a point at the top with 16 cm x 16 cm x 3 mm thick copper Base plate and necessary nuts and bolts with washer. | 8 | Each | |
| 201 | 3 | Providing and fixing, testing joint made of 20 mm x 3 mm thick copper strips 125 mm long with 4 nos. brass bolts and nuts, checknuts with washer complete | 8 | Each | |
| 202 | 3.01 | Under Ground Cables.Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections,digging and refiling of trenches. . 240 Sq. mm 3.5 Core Armoured Cable. | 80 | Mtr. | |
| 203 | 3.02 | 10 sq mm 4 Core cable | 300 | Mtr. | |
| 204 | 3.03 | 16 sq mm 4 Core cable | 280 | Mtr. | |
| 205 | 3.04 | 25 sq mm 4 Core cable | 160 | Mtr. | |
| 206 | 3.05 | Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections:- 35 Sq. mm 3.5 Core Armoured Cable. | 540 | Mtr. | |
| 207 | 3.06 | 50 Sq. mm 3.5 Core Armoured Cable. | 100 | Mtr. | |
| 208 | 3.07 | 70 Sq. mm 3.5 Core Armoured Cable. | 100 | Mtr. | |
| 209 | 3.08 | 120 Sq. mm 3.5 Core Armoured Cable. | 160 | Mtr. | |
| 210 | 3.09 | 240 Sq. mm 3.5 Core Armoured Cable. | 120 | Mtr. | |
| 211 | 3.1 | 300 Sq. mm 3.5 Core Armoured Cable. | 160 | Mtr. | |
| 212 | 3.11 | 10 sq mm 4 Core cable | 880 | Mtr. | |
| 213 | 3.12 | 16 sq mm 4 Core cable | 1700 | Mtr. | |
| 214 | 3.13 | 25 sq mm 4 Core cable | 820 | Mtr. | |
| 215 | 3.14 | Supply and erection of suitable compression type brass cable glands for underground Cable. 10 Sqmm to 16 Sqmm Cable 2 to 4 Core . | 144 | each | |
| 216 | 3.15 | 25 Sqmm to 50 Sqmm Cable 2 to 4 Core. | 128 | each | |
| 217 | 3.16 | 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core | 64 | each | |
| 218 | 3.17 | 120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core | 24 | each | |
| 219 | 3.18 | 240 Sqmm Cable 3 to 3.5 Core . | 32 | each | |
| 220 | 3.19 | 300 Sqmm Cable 3 to 3.5 Core . | 32 | each | |
| 221 | 3.2 | Erection of street light fitting on the pole including the cost of petty material required ( irrespective of height / length of bracket ). Pole above 8 metres | 30 | Each | |
| 222 | 3.21 | Supply and erection of Godrej Almirah type M.S.pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S.sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- M.S.pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 750 mm x 450 mm x 200 mm above ground level duly plastered with 12 mm thick 1:4 cement plaster , having a base of size 900 mm x 600 mm x 250 mm below ground level. Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm . | 272 | EACH | |
| 223 | 3.22 | 16 sqmm . | 272 | EACH | |
| 224 | 3.23 | 25 sqmm . | 240 | EACH | |
| 225 | 3.24 | 35 sqmm . | 128 | EACH | |
| 226 | 3.25 | 50 sqmm . | 32 | EACH | |
| 227 | 3.26 | 70 sqmm . | 32 | EACH | |
| 228 | 3.27 | 120 sqmm . | 16 | EACH | |
| 229 | 3.28 | 240 sqmm . | 48 | EACH | |
| 230 | 3.29 | 300 sqmm . | 64 | EACH | |
| 231 | 3.3 | PVC Insulated wiring in recessed 1.6 mm thick MS conduit pipe with 1.5 sq.mm PVC Insulated copper conductor cable with modular accessories. Fan Point Medium Point | 585 | Each | |
| 232 | 3.31 | Long Point | 410 | Each | |
| 233 | 3.32 | Light point Short point | 1128 | Each | |
| 234 | 3.33 | Medium Point | 1559 | Each | |
| 235 | 3.34 | Long point | 1379 | Each | |
| 236 | 3.35 | Twin control light point with 2 ways 5 amp single pole switch Medium Point | 96 | Each | |
| 237 | 3.36 | Long point | 96 | Each | |
| 238 | 3.37 | Call bell point i/c MS box of size 180mmx100mmx60mm deep for call bell. Long point | 12 | Each | |
| 239 | 3.38 | 3 pin, 5 amp. Plug point i/c earthing the 3rd pin etc. Short point | 1449 | Each | |
| 240 | 3.39 | Medium Point | 55 | Each | |
| 241 | 3.4 | Long Point | 26 | Each | |
| 242 | 3.41 | 3 pin,15amp plug point with 4 sqmm PVC insulated copper conductor cable i/c earthing the 3rd pin etc. | |||
| 243 | 3.42 | Medium Point | 194 | Each | |
| 244 | 3.43 | Long Point | 198 | Each | |
| 245 | 3.44 | Light point without control- Medium point. | 114 | Each | |
| 246 | 3.45 | Light point without control- Long point. | 192 | Each | |
| 247 | 3.46 | S/E of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Cable size 1.5 sqmm(3/0.81mm) | 10800 | Mtr. | |
| 248 | 3.47 | Cable size 2.5 sqmm(3/1.05mm) | 4800 | Mtr. | |
| 249 | 3.48 | Cable size 4 sqmm(7/0.85mm) | 7000 | Mtr. | |
| 250 | 3.49 | Size 6 sqmm ( 7 / 1.05mm). | 1900 | Mtr. | |
| 251 | 3.5 | Size 10 sqmm | 560 | Mtr. | |
| 252 | 3.51 | Size 16 sqmm | 560 | Mtr. | |
| 253 | 3.52 | S/E of double door sheet steel enclosure distribution suitable for MCBs and ELCBs etc. recessed in wall i/c board with all labour and material required to complete the job in all respect upto to the entire satisfaction of the EIC of the work. 4-way, TP & N (Horizontal) (8+12) | 52 | Each | |
| 254 | 3.53 | 8-way, TP & N (Horizontal) (8+24) | 47 | Each | |
| 255 | 3.54 | 4-way, TP & N (Verticall) (8+12) | 2 | Each | |
| 256 | 3.55 | Supply and erection of double pole / Four pole Residual current circuit breaker ( RCCB / ELCB) suitable for operation on 240/415 V, 5 Hz. AC supply installed in existing sheet steel enclosure including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. 40A / 415V 4P ELCB with 100mA senstivity. | 40 | Each | |
| 257 | 3.56 | 63A / 415V 4P ELCB with 100mA senstivity. | 54 | Each | |
| 258 | 3.57 | Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work.25 mm dia | 840 | P/Mtr. | |
| 259 | 3.58 | P/F modular type accessories of approved make in existing box i/c fixing and making necessary connection, complete in all respect. Fan Regulator | 990 | Each | |
| 260 | 3.59 | Call bell Ding-Dong(Monitca) | 16 | Each | |
| 261 | 3.6 | Blinking plate | 90 | Each | |
| 262 | 3.61 | 10amp 1 way switch | 6810 | Each | |
| 263 | 3.62 | 10amp 2 way switch | 197 | Each | |
| 264 | 3.63 | 20 amp switch | 397 | Each | |
| 265 | 3.64 | 10 amp socket | 1535 | Each | |
| 266 | 3.65 | 16 amp socket | 397 | Each | |
| 267 | 3.66 | Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR31.57) 1 & 2 Modules | 210 | Each | |
| 268 | 3.67 | 3 Modules | 1210 | Each | |
| 269 | 3.68 | 4 Modules | 20 | Each | |
| 270 | 3.69 | 6 Modules | 615 | Each | |
| 271 | 3.7 | 8 Modules | 110 | Each | |
| 272 | 3.71 | 12 Modules | 605 | Each | |
| 273 | 3.72 | Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends inspection boxes , iron hooks, cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work. PVC pipe of 32 mm dia | 240 | P/Mtr. | |
| 274 | 3.73 | PVC pipe of 40 mm dia | 216 | P/Mtr. | |
| 275 | 3.74 | Supply, Installation, Testing and Commissioning of wall / free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable tray separating switches compartment and supporting suitable channel duly painted by 2 coat zinc / red oxide primer followed by 2 coats of powder coating in grey or required shade after rising. the panel having PU / Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipments / switch wear. Transport acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The Panel will be complete with control wiring (Copper) and fuse protection. (Only outer area on all sides shall be measured).\n(Make of the panel should be of approved make and is tested from the engineer-in-charge / consultant.\nNote:- The Cost of MCCB's, MCB's, COS , rotary handles and metering etc are NOT included in the panel cost. And shall be paid under seprate head . The cost of all other accessories/wiring are included in the panel cost complete in all respect . MAIN L.T Panel INCOMER 1000A. FP 50KA EDO Type - 1 Nos.OUTGOING MCCB 800A. FP 50 K A - 1 Nos. MCCB 500A. -1 Nos.MCCB 200A.-5 Nos.MCCB 100A.-1 Nos.Dummy - 2 Nos. AC PANEL - =1NO. INCOMER MCCB 800A FP 50A-1NOS. OUTGOING MCCB 300A-5 NOS. DUMMY- 2NOS.EMERGENCY PANEL =1NO. INCOMER COS MCCB 500A FP-1NOS MCCB 500A-1NOS. OUTGOING MCCB 200A-2NOS, MCCB 100 A -5NOS, MCCB 63A -3NOS., DUMMY -2NOS.LIFT PANEL =1NO. INCOMER MCCB 200A,36A -1NOS OUTGOING MCCB 63A -5NOS. DUMMY-2NOS. TOTAL PANELS = 1 + 2 +3 +4= | 240 | Sq/Meter | |
| 276 | 3.75 | Supply and Fixing of copper bus bar duly tinned by means of SMC / DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with color coding heat shrinkable PVC insulation complete in all respect. | 1360 | kg | |
| 277 | 3.76 | Providing and Fixing of digital metering equipments for LT cubical panel consisting of 96 mm x 96 mm 0-500 Volt, Voltmeter with selector switch, Amp.ere meter of required ratio up to 600/5 Amp.. with selector switch and required CT's 3 Nos., a set of 3 Nos. phase indication lAmp.s RYB LED. | 12 | p/set | |
| 278 | 3.77 | Supply and Fixing of rotary handle for ON / OFF operation of existing MCCB in the LT panel including fixing the same in position with all labour and material to required to complete the job in all respect. Rotary Handle up to 125 Amp.., MCCB | 38 | each | |
| 279 | 3.78 | Rotary Handle above 125 Amp.., MCCB | 38 | each | |
| 280 | 3.79 | S/E of mark double walled corrugated(DWC)HDPE pipe laid 1 mtr. Below ground level i/c diging and refilling of earth i/c cost of suitable size socket/ cuppler for HDPE pipe i/c the cost of labour and material required to complete the job in all respect up to the entire satisfaction of EIC of the work.HDPE pipe 63/50mm outer dia/ inner dia. | 1000 | Each | |
| 281 | 3.8 | HDPE pipe 90/75mm outer dia/ inner dia. | 200 | Each | |
| 282 | 3.81 | Supply and Erection of Hot Dip Galvanized octagonal pole of 3 mm thickness, with base plate including cost of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galvanized pole complete with door locking arrangement, Terminal plate consisting of 2 nos. 100 Amp., 4 pole neutral links including connection etc. with suitable connecting arrangements for 2 No. MCB's / Kit-Kat including cost of R.C.C 1:1, 5:3 for foundation of size 0.7 M x 0.7 M x 1.8 M with minium 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm C.C for fixing the pole with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.9 Mtr. Long pole with top dia 70 mm and bottom dia 130 mm with base plate of size 220 mm x 225 mm x 12 mm. | 30 | Each | |
| 283 | 3.82 | Supply and erection of module case circuit breaker single pole/ 4 pole on wall /on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 63 Amp. | 21 | Each | |
| 284 | 3.83 | 4 pole MCCB 100 Amp.. | 22 | Each | |
| 285 | 3.84 | 4 pole MCCB 200 Amp. | 24 | Each | |
| 286 | 3.85 | 4 pole MCCB 300 Amp 400AMP | 10 | Each | |
| 287 | 3.86 | 4 pole MCCB 500 Amp | 10 | Each | |
| 288 | 3.87 | Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and shealed in existing pipe/Channel and making necessary connection complete in all respect upto the entire satisfaction of the Engineer-in-Charge of the work.2 Pair Telephone Wire | 1300 | P/Mtr. | |
| 289 | 3.88 | Supply & erection of cable tray made out of 2 mm thick galavanised perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the Job in all respect upto the Entire statisfaction of Engineer-in-Charge of the work.40 x 100 mm | 160 | P/Mtr. | |
| 290 | 3.89 | 50 x 150 mm | 140 | P/Mtr. | |
| 291 | 3.9 | Supply & erection of factory manufactureed cable tray cover made of 16g GI Sheet complete with Fastoner Nuts bots and in position including all petty material required to complete the Job in all respect upto the Entire statisfaction of Engineer in Charge of the work Suitable for 50 x 150 mm | 160 | P/Mtr. | |
| 292 | 3.91 | Suitable for 50 x 300 mm | 140 | P/Mtr. | |
| 293 | 3.92 | Supply & Erection , testing and commisioning of ACB 1000 AMP 4 POLE 50KA EDO TYPE MP RELEASE including all petty materials required to complete the job in all respect. | 2 | Each | |
| 294 | 3.93 | Supply & Erection , testing and commisioning of ACB 800 AMP 4 POLE 50KA EDO TYPE MP RELEASE including all petty materials required to complete the job in all respect. | 4 | Each | |
| 295 | 3.94 | Supply & Erection , testing and commisioning of DB VTPN 4 MCCB INCOMER UPTO 160 AMP DOUBLE DOOR IP-63 including all petty materials required to complete the job in all respect. | 2 | Each | |
| 296 | 3.95 | Supply & Erection , testing and commisioning of DB VTPN 6 MCCB INCOMER UPTO 160 AMP DOUBLE DOOR IP-63 including all petty materials required to complete the job in all respect. | 8 | Each | |
| 297 | 3.96 | Supply & Erection , testing and commisioning of DB VTPN 6 MCCB INCOMER UPTO 250 AMP DOUBLE DOOR IP-63 including all petty materials required to complete the job in all respect. | 8 | Each | |
| 298 | 3.97 | Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceillingetc. Including cost of Pvc Bends, Inspection Box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-charge of work. 25 mm dia | 2400 | P/Mtr. | |
| 299 | 3.98 | Supply and erection of pipe for wiring purpose including bends inspection boxes etc. where necessary and painting as required. Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed. | 1600 | P/Mtr. | |
| 300 | 3.99 | RAINWATER HARVESTING - HSR ITEMS: | |||
| 301 | 4 | Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding\n2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed within a lead of 30 Mtrs. (HSR 6.6) | 148.58 | cum | |
| 302 | 4.01 | Centering & shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. inclination not exeding 25 degree with horizontal. (HSR 9.1) | 34.32 | sqm | |
| 303 | 4.02 | Cement concrete 1:4:8 with stone aggregate\n40 mm nominal size in foundation & plinth. (HSR 10.39) | 5.26 | cum | |
| 304 | 4.03 | Cement concrete 1:1.5:3 with stone aggregate\n20 mm nominal size for reinforced concrete work in slabs with with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respect. [HSR. 10.82 + 10.95 (a)]. | 5.14 | cum | |
| 305 | 4.04 | First class brick work laid in cement sand mortar 1:6 in foundation and plinth . (HSR 11.2) | 36.72 | cum | |
| 306 | 4.05 | 1st class spotless uniform color Kotah stone Flooring (RAATIA Variety) , minimum 25mm thick, in any pattern as specified over 20 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including single piece used in staircase and minimum 550x550mm in flooring, Granite rubbing and polishing.\n(Note :- No extra rate for granite rubbing will be paid. Contractor should quote the rate accordingly.) (HSR 14.62) \n | 1.44 | sqm | |
| 307 | 4.06 | 12mm thick cement Plaster 1:4. (HSR 15.5). | 108.66 | sqm | |
| 308 | 4.07 | Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12). | 0.06 | Qlt. | |
| 309 | 4.08 | Steel Reinforement TMT bars Fe-500D EQR/ FE 500D grade or more for RCC work, where not included in the complete rate of RCC including straightening , bending, binding, wastage,overlap,welded joints spacer bars , chairs,stays,hangers and annealed steel wire etc & placing in the position complete in all respects for all height /depth/storeys/ basement etc.\n( NOTE :- Reinforcment shall be measured in length including hooks, if any, separately for diferent diameters as actually used in work, excluding Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcment. ) | 10.28 | Qlt. | |
| 310 | 4.09 | Boring for hand-pump in clay, fitting strainer and pipe (b) above 75 mm dia bore, but not exceeding 100 mm dia (i) from 0 to 15 meter. [HSR 26.10 (b)].(i) | 33.1 | Metre | |
| 311 | 4.1 | Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below: (HSR 28.50)a) Filter media fine graded 1.5 mm to 3 mm | 12.48 | cum | |
| 312 | 4.11 | (c) Filter media course Bajri 6 mm to 20 mm | 12.48 | cum | |
| 313 | 4.12 | (d) Filter media boulders 50 mm to 75 mm | 24.98 | cum | |
| 314 | 4.13 | Constructing brick masonry inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent limer mortar 2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2;4 slab 100 mm thick./C.C. topping 50 mm thick with 455 mm x 455 mm 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint coplete as per standard design. [HSR 29.84]. (a) Size 450 mm x 450 mm | 6 | Each | |
| 315 | 4.14 | Extra for over 0.30 metre depth of inspection chamber. (a) 450 x 450 mm. (HSR 29.85) | 6 | Per 0.30 Meter depth | |
| 316 | 4.15 | Providing and fixing SFRC manhole covers and frames markd with IS: 12592 including setting the same to correct lines and levels in 1:2 cement sand mortar over manhole including carriage loading, unloading stacking, handling, re-handling etc. complete in all respect to the satisfaction of engineer-in-charge. Type: Extra heavy duty set (MD-10) 560 mm clear opening. (HSR 29.94) | 4 | Each | |
| 317 | 4.16 | LANDSCAPING WORKS -SOR ITEMS:- | |||
| 318 | 4.17 | Supplying at site of work well decayed farm yard manure, from approved source, including screening and stacking. | 893.7 | Cum | |
| 319 | 4.18 | Maintenance of lawn with fine grass mowing with the help of shrubs master for the 1st year including watering etc. | 16895.2 | Sqm | |
| 320 | 4.19 | Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed fary yard manure.\nSize of pit 0.75X0.75 x0.75 m deep | 874 | Each | |
| 321 | 4.2 | Turfing of lawn with planting of selection No. 1 superior quality grass with machinery including ploughing the land, levelling and dressing, applying farm yard manure in 2.5cm layer, application of insecticide/pesticide to safe guard against soil borne diseases. | 2857.44 | Sqm | |
| 322 | 4.21 | Planting flower beds including digging and refilling of beds with excavated soil and FYM fertilizer and insecticides planting of sapling at 30cm distance of plant to plant and row to row.\nArea for Seasoal Flowers | 10000 | Sqm | |
| 323 | 4.22 | Maintenance of flower beds for one year including 27 No. waterings @ 4 waterings in the months of March, April, May and June, 2 No irrigations each in the months of February, October, November and December and one irrigation each in July, August and September | 2608 | Sqm | |
| 324 | 4.23 | Providing and fixing steel tree guards having 3 Nos. legs of angel iron size 25x25x3mm 1.8 mtr. height, 3 Nos. rings of MS bars 8mm thickness 60 cm. dia and fixing of wire mesh size 3.81x7.62 cm. around the angel iron complete in all respects. | 874 | Each | |
| 325 | 4.24 | HSR FROM DSR | |||
| 326 | 4.25 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer ofslurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. Thislayer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixedwith water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hoursfollowed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints including joints at core for pipes, corners, junctions of pipes and masonry with polymer mixed slurry.(DSR 22.5)\nNote : Photographs of execution and work after execution will be attached with the bill while paying this item. All bills of material of items involved in this item will also be attached. | 2205.4 | Sqm | |
| 327 | 4.26 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills,facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,\nincluding rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (2) Payment/ Measurment willl be made as per finished floor/wall etc on actual basis.(DSR 8.2.2.2) | 3141.8 | Sqm | |
| 328 | 4.27 | Providing and fixing fire resistant door frame of section 50 x 60 mm on\nhorizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm\nfor fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded). (DSR 9.161) | 244 | METRE | |
| 329 | 4.28 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60\nmm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).(DSR 9.162) | 154.8 | Sqm | |
| 330 | 4.29 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including\napplying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.(DSR 9.164) | 7.2 | Sqm | |
| 331 | 4.3 | Providing and fixing panic bar / latch (Double point) 1500 mm long fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. (DSR 9.139) | 80 | Each | |
| 332 | 4.31 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1mm thick (DSR 9.127.2) (Merino, Greenlam, Century,Duro make only). | 5485.01 | Sqm | |
| 333 | 4.32 | P/F G.I. chain link fencing of required width in mesh size 50x50 mm i/c stren- gthening with 2 mm dia. wire: Made of GI of dia. 4 mm. (DSR 16.70.1) | 1638 | Sqm | |
| 334 | 4.33 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.ON STEEL WORK (DSR 13.52.1) | 3231.76 | SQM | |
| 335 | 4.34 | Providing and fixing of Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work Concealed/Exposed on walls.(Make Supreme/Finolex/ Prince). \nNote:- Pipes and fittings with \"Flow Gaurd\" technology as per CTS Standard dimensional ratio (SDR) :11 (Class 1) Pipes at a working pressure of 27.6 Kg / sq.cm at 23 degree celsius using moulded Chlorinated Polyvinyl Chloride (CPVC) fittings i.e. Tees, Elbows, Couplers, Unions, Reducers , etc. incl transitions fittings connection between CPVC and Metal Pipes / GI Pipes with Brasss adaptors (both Male & Femal End) Confirming to ASTM D 2846 with only CPVC solvent cement Confirming to ASTM F-493.\n(ii)20 mm internal diameter of pipeline | 2370.2 | Metre | |
| 336 | 4.35 | Providing and fixing GI PIPE B class(JINDAL HISAR/TATA make) in complete with G.I. fittings and clamps,i/c cutting and making good the walls etc.\nInternal work Exposed on walls.\n | |||
| 337 | 4.36 | 25 mm internal diameter of pipeline | 1524.92 | Metre | |
| 338 | 4.37 | 32 mm internal diameter of pipeline | 538.5 | Metre | |
| 339 | 4.38 | 40 mm internal diameter of pipeline | 570 | Metre | |
| 340 | 4.39 | 50 mm internal diameter of pipeline | 267 | Metre | |
| 341 | 4.4 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) Make: Hindware or Kerovit or Jaguar or Parryware | 136 | Each | |
| 342 | 4.41 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. (DSR 17.2.1) Hindware or Kerovit or Jaguar or Parryware | 143 | Each | |
| 343 | 4.42 | CIVIL WORK - NON SCHEDULED ITEMS : | |||
| 344 | 4.43 | Carriage of excavated Earth, Layimg in layers and compaction for Disposal upto any lead complete in all respects within the New Campus of LUVAS as per direction of Engineer-in-charge | 17775.4 | cum | |
| 345 | 4.44 | Earth Filling under floors with Tibba sand taken from outside the campus area with all lead & lift, including loading, unloading, laid in 25 cm layers including campaction upto 98% of SPD with sheep foot roller/ soil compactor, watering compensation of earth etc. complete in all respect with entire satisfaction of Engineer in charge. (N.S.ITEM) Note : Density to be chacked layer wise and recored in register.(Note:- This rate is without campansation. if the agency bring a certifucate dully certified by revenue authority that the contactor campasation to the land owner, payment on this account will be made as HSR 6.4 item+ CP aplicable on the date of tender) | 30033.9 | cum | |
| 346 | 4.45 | Supply & erection of GRC screens( jali) 50 mm thick in approved designs & sizes factory manufactureed containing alkali resistant Glass Fiber of make NEG, Japan and fixing by Dry Cladding using SS Cleats, SS Threading rods/ Hiltti make fastner with epoxy resign as per design, Self Tapping Screws etc. complete including scaffolding and all other plants and machinery with all type of labour . ( Unicrete ,Mahesh GRC, Unistone) with entire satisfaction of Engineer in charge. (N.S.ITEM) | 2705.98 | Sqm | |
| 347 | 4.46 | Factory-manufactured wire gauze door and windows shutters of commercial hard wood such as hollock, champ only conforming to I.S. specification no. 1003, kiln seasoned with 100 mm wide vertical styles, 150mm wide lock rail 200 mm wide bottom rail, and combination of ( SS 304 G mosquito mesh ( 120 G or 140 G designations) and Aluminium Mesh with opening 10mm x 10mm 1.6 mm thick ) including cost of iron hinges, screws, chock /cleats, stops nails etc, complete fixed in position ( excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position.)\n(a) 30 mm thick | 1720.98 | Sqm | |
| 348 | 4.47 | Providing & fixing heavy Duty S.S Handle bolt (5\" long) with nuts & screws etc complete.(Grade 304) | 12656 | Each | |
| 349 | 4.48 | Providing & fixing Stainless Steel Fittings Heavy Duty (Chrome Finished) to doors,window,cupboard etc. (Grade 304) with nuts & screws etc complete.(as per sample approved by Engineer-in-charge).\n(i) S.S tower bolt (8\" long) | 1004 | Each | |
| 350 | 4.49 | Providing & fixing Heavy Duty. S.S tower bolt (6\" long) with nuts & screws etc complete. (Grade 304)\n( Note :- Toilet shutter will also be provided tower bolt 6\" long) | 10504 | Each | |
| 351 | 4.5 | Providing & fixing Heavy Duty S.S Sliding bolt (250mm x 16 mm dia) with nuts & screws etc complete.(Grade 304) | 62 | Each | |
| 352 | 4.51 | Providing & fixing Heavy Duty S.S Sliding bolt (200mm x 16 mm dia) with nuts & screws etc complete.(Grade 304) | 549 | Each | |
| 353 | 4.52 | 150 mm floor S.S front Door stoppers (Godrej or equivalent make) with rubber cushion screws etc to suit shutter thickness complete. | 3122 | Each | |
| 354 | 4.53 | Providing and fixing in position Stainless steel sheet 200 mm wide Grade 304 plate-1.0 mm thick with slotted holes bevelled edges fixed with rawl plugs on one side & 100 mm SS Screws @300 mm C/C as per design for expansion joints.(i) 200mm wide.(N.S ITEM) | 2400.53 | Kg | |
| 355 | 4.54 | Providing and laying two courses of water proofing treatment with bitumen felt consisting of first courses of blown tyye bitumen grade 85/25 applied hot at 1.20 kg per sqm of area for each course, second course on surface in foundation, felt type 3 grade-I (Hessian base self finished bitumen felt) including preparation of surface complete. (HSR 13.61-Note 13.63- note foot note 10.115) (27.85-1.25-8.45=18.15) (18.15x240%+18.15=61.71) | 10158 | Sqm | |
| 356 | 4.55 | Providing and laying VDC ( Vaccum Dewatered Concrete) pavement in Road and Parking of design mix M-35 with minimum cement content 350 Kg/Cum with design mixed concrete from automatic batching plant. , using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading with CC Pavement Paver and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 6 mm wide x 65 mm deep joint) in contraction joints and (10 mm wide x 200 mm) deep expansion joint at every 30 m lenth of road ) by groove cutting machine, providing and filling joints with Polysulphide Pour Grade sealent ( Make SIKA ), complete all as per direction of Engineer-in-charge(Item of dowel bars / tie bars to be paid separately under item of HSR 18.22 ). | 188.83 | CUM | |
| 357 | 4.56 | Providing and laying of Pu Floor coating 1.5 mm system on the concrete surface which is free from all dust ,dirt,debris or any other foreign particle which may effect adhesion of the topping with the concrete surface . The surface preparation should be done using mechanical means apply primer coat on cleaned surface curing time 8-12 hours after that apply the fast setting self leveling underlayment so as to achieve the thickness 1 mm ( curing time 24 hour) allow to get dry before applying PU coat (100% solid content ) Let the floor be cured for minimum 48 hours depending on temperature to allow for foot traffic. | 627.105 | SQM | |
| 358 | 4.57 | Providing and fixing Double Charged vitrified tiles of size 600 x 600mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with White cement slurry mixed with pigment to match the shade to tiles. \nNote:- 1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO. (Note: Double Charged Vitrified tiles shall be used.)\n2. Tile Shall be provided with 3mm thick groove and filled the same with Epoxy Grout of reputed brands such as pidilite, laticrete, ferrouscrete & valendure as per IS specifications 15477-2004.\n3. Tiles will be covered after execution and will remain covered till the completion of work to avoid any damage to tiles.\n(Note :- In toilets antiskid vitrified tiles will be used. The contractor should quote the rate as per nomenclature above. Nothing extra will be payable on any account)\n(a) First Storey | 3169.17 | Sqm | |
| 359 | 4.58 | Second Storey | 3007.49 | Sqm | |
| 360 | 4.59 | Third storey | 2279.56 | Sqm | |
| 361 | 4.6 | Fourth storey | 2279.56 | Sqm | |
| 362 | 4.61 | Fifth Storey | 2279.56 | Sqm | |
| 363 | 4.62 | Providing and fixing Double Charged vitrified tiles of size 600 x 600mm of approved make in skirting/dados laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with White cement slurry mixed with pigment to match the shade to tiles. \nNote:- 1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO. (Note: Double Charged Vitrified tiles shall be used.) \n2. Tile Shall be provided with 3mm thick groove and filled the same with Epoxy Grout of reputed brands such as pidilite, laticrete, ferrouscrete & valendure as per IS specifications 15477-2004. \n(a) First Storey | 287.21 | Sqm | |
| 364 | 4.63 | Second Storey | 267.27 | Sqm | |
| 365 | 4.64 | Third storey | 294.48 | Sqm | |
| 366 | 4.65 | Fourth storey | 294.48 | Sqm | |
| 367 | 4.66 | Fifth Storey | 294.48 | Sqm | |
| 368 | 4.67 | Providing and fixing Ist quality ceramic glazed wall tiles 300 X 600 MM with highlighters conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades , or any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.\nNote: \n1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO.\n2. Combination pattern of floor and wall tiles will be approved by University and no claim will be entertained.\n3. Nothing Extra will be paid for using Highlighters on walls.\n | 17241.1 | Sqm | |
| 369 | 4.68 | Providing & Applying high quality acrylic modified resin based texture paint of Dholpur/Red sand stone ( Smooth Stone series) Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm complete including scaffolding up to 6 storey building as the direction of Engineer -in-Charge.\n( Make Heritage, Spectrum, SKK ) | 8235.02 | Sqm | |
| 370 | 4.69 | Supply and fixing factory manufactured Modular Wardrobre cum Study Unit (600mm deep) as per drawing/design approved by Engineer-in-charge (make ALCON/ALNO/NOLTE). Drawing attached with BOQ.\nCarcass made of 18mm Both Side Laminated Postlam BWP Grade Plywood (Century or Duro, water proof and termite treated) with 0.8mm Edgeband on exposed sides.\nShutters made of 18mm Both side laminated HDHMR with 2mm Edgeband on exposed sides with Snap on Sensys Soft Close Hinges (Make : Ebco/Hettich/Hafele).\nDrawers made of 18mm Both Side Laminated Postlam BWP Grade Plywood with 0.8mm Edgeband on exposed sides with Soft Close Telescopic channels (Make - Ebco/Hettich/Hafele).\nWardrobe has to be included with Oval Anodized Hanging Rod with Brackets, PVC Leg & Skirting(Silver Finish), Linear Handle on shutters/Drawers (Make - Rehau/Sparx/ Ebco/ Hettich), \nCracass has to be Jointed with Minifix, Wooden & Cabinet Connectors Predrilled Dowel in All Carcass with CNC Machine for Strength & Precsion (Make - Ebco/ Hettich/ Hafele) & Camar Wall hanging Bracket with provision for Horizontal and Vertical alignment (Made in Italy) complete in all respects as per Drawing, All hardware to be fixed and direction/upto to the entire satisfaction of Engineer-in-charge.\n(Note :- 1. Colour to be decided by the University ) \n2. Only front elevation measurement of wardrobe shall be measured for Payment. | 3228.24 | Sqm | |
| 371 | 4.7 | Pre Construction work (i) providing and injection chemical emulsion for pre constructional antitermite treatment and creating chemical barrier under and around the column pits, wall treanches basement excavation , top surface of plinth filling junction of wall and floor along with external perimetre of building , expansion joints surrounding of pipes and conduit etc, complete ( plinth area of the building at ground floor only shall be measured ) Note :- Work to be executed with premise Imidacloprid 30.5% of bayer company through valid licence holder on form 6C of commercial pest control .Performance guarantee for 10 years through BG of 10% amount of the item amount. The work will be done as per ISI Code on Pre Construction Anti termite treatment. | 6491.86 | Sqm | |
| 372 | 4.71 | PUBLIC HEALTH - NON SCHEDULED ITEMS: | |||
| 373 | 4.72 | Providing and fixing in position \"B\" Class SWR Ring fit Pipes single socket as per IS : 13592 including jointing with seal ring confirming to IS:5382 complete with specials/Tee's/Bends as per IS :14735 as required at site complete as per instruction of Engineer in Charge.\n(a)110 mm Dia. O/D | 1511.34 | Metre | |
| 374 | 4.73 | (b)90 mm Dia. O/D | 2168.9 | Metre | |
| 375 | 4.74 | Providing & Fixing UPVC SWR floor traps with 75 mm i/d outlet. I.S.I. marked of the self cleaning design including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc. minimum depth of water should be 50 mm with a minimum seal of 50 mm. complete in all respects. | 416 | Each | |
| 376 | 4.75 | Providing & Fixing Stainless steel Jali ( 100 mm dia) 304 G for Floor trap including cutting and making good the walls and floors complete in all respects.(Make VIKING) | 416 | Each | |
| 377 | 4.76 | Providing and laying DWC Pipe SN4 Class for sewage disposal including lowering,cutting,jointing,and testing including the cost of jointing material and all accessories complete in all respects to the entire satisfaction of Engineer-in-Charge. (MAKE:- Supreme/Prince/ Astral)\n(a) 150 mm Dia Pipe | 170 | Metre | |
| 378 | 4.77 | (b) 200 mm dia | 520 | Metre | |
| 379 | 4.78 | ELECTRICAL WORKS - NON SCHEDULED ITEMS: | |||
| 380 | 4.79 | Earthing - Copper Bonded Steel with 23.2 mm dia. Supply, Installation, Testing & Commissioning of long life Maintenance Free Earthing System . The Rod shall be of Copper Bonded Steel with 23.2 mm dia. and 10 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm tested by CPRI capable of bearing fault current of 50kA. Along with earth enhancement compound (jam plus) tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 30 kg (10 kg Bag x 3) resistivity is less than 0.2 ohm meter. The earth station shall be with Suitable Poly-plastic Pit Cover with lockable arrangement. (for neutral and body 500 kva transformer) including cost of petty material required to complete the job in all respect. Copper Bonded Steel with 14.2 mm dia. Make: JMV or equivalent model of ERICO, OR FURSE, OBO. | 26 | EACH | |
| 381 | 4.8 | Supply erection of Expansion piece of made of 8mm aluminium at every 20 mtr to maintain the flexibility to the conductor due to heat. including cost of petty material required to complete the job in all respect. Make: JMV, OBO BATTERMAN OR ERECO. | 16 | Nos. | |
| 382 | 4.81 | Supply erection testing and commissioning of Recessed / Surface mounted round LED downlighter 12 WATT ( +_2w ) . With Die Cast Heat Sink LED EFFICACY 100 Lumens / Watt including petty materials required to complete the job in all respect. WIPRO Make , Model :- CRDL11R017HP57 or Equivalent in Philips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice. | 362 | Each | |
| 383 | 4.82 | Supply, installation, testing and commisioning of Led Recess mounted downlighter 18W+/- 1W Square LED downlighter fixture with minimum system efficacy 85lm/W with die cast aluminium housing for better heat dissapation having HET non-yellowing PMMA diffuser.The LED luminaire shall have power factor more than 0.9 with THD less than 10%. LED Driver Output voltage shall be less than SELV Limits for safe operation and maintenance. including all petty materials required to complete the job in all respect. Wipro Cat. No CRDL11R023HP57 or equivalent make in Philips or Trilux / Crompton. LM79 REPORT FROM 'NABL' LAB SHOULD BE SUBMITTED | 774 | Each | |
| 384 | 4.83 | Supply erection testing and commissioning of Recess / Surface mounted 2' x 2' panel 36 WATT ( +_ 2 watt ) LED Efficacy 120 Lm/w. Luminaire including petty materials required to complete the job in all respect. WIPRO Make , Model :- CRCO10R038HP57GL1 or Equivalent in ilips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice.\n | 46 | Each | |
| 385 | 4.84 | Supply erection testing and commissioning of Surface mounted Recess / Surface mounted 4' x 1' panel 31 WATT ( +_2 watt ) LED Efficacy 120Lm/w. including petty materials required to complete the job in all respect. WIPRO Make , Model :- CRCO13R038HP57G1 or Equivalent in Philips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice.. | 1234 | Each | |
| 386 | 4.85 | Supply, installation, testing and commissioning of LED batten 20 watt (+_ 2 w ) LED Efficacy 100Lumens / Watt including petty materials required to complete the job in all respect. WIPRO Make , Model :- LL20-281-XXX-65AL1 or Equivalent in Philips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice. | 618 | Each | |
| 387 | 4.86 | Supply, installation, testing and commissioning of LED Mirror Light 10 watt (+_ 1 w ) LED Efficacy 100Lumens / Watt including petty materials required to complete the job in all respect. WIPRO Make , Model :- LL20-111-XXX-65-NE or Equivalent in Philips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice. | 50 | Each | |
| 388 | 4.87 | Supply, installation, testing and commissioning of LED STREET LIGHT WITH EXTRUDED ALUMINIUM HEAT SINK 45 WATT ( +_ 2 w ) LED Efficacy 100 Lumens / Watt including petty materials required to complete the job in all respect. WIPRO Make , Model :- LR02-501-XXX-57-G1 or Equivalent in Philips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice. | 20 | Each | |
| 389 | 4.88 | Supply erection testing and commissioning of LED BULK HEAD WITH 10WATT FITTING (+_1 w )LED EFFICACY 100 Lumens/ Watt . including petty materials required to complete the job in all respect. WIPRO Make , Model :-LW07-141-XXX-57-XX or Equivalent in Philips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice. | 40 | Each | |
| 390 | 4.89 | Supply, installation, testing and commisioning of Hanging Decorative light shaped suspended luminaire led lamp extra 15 W. including all petty materials required to complete the job in all respect. WIPRO Make , Model :-Equivalent in Philips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice | 68 | Each | |
| 391 | 4.9 | Supply, installation, testing and commisioning of LED STEP LIGHT THREE MODULE including COST OF GI BOX. including all petty materials required to complete the job in all respect. WIPRO Make , Model :-Equivalent in Philips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice | 160 | Each | |
| 392 | 4.91 | Supply, installation, testing and commisioning of LED BED LIGHT. including all petty materials required to complete the job in all respect. WIPRO Make , Model :-Equivalent in Philips / Trilux as approved by the Engineer-in-charge. Warranty 2 years from the Date of invoice | 816 | Each | |
| 393 | 4.92 | Supply, Installation, Testing and Commissioning, of A.C. CEILING FAN 48\" (1200MM) SWEEP, 5 Star Rating including cost of petty material required to complete the job in all respect. Make : ORIENT,HAVELLS ,CROMPTON | 909 | Each | |
| 394 | 4.93 | Supply, Installation, Testing and Commissioning, of A.C. CEILING FAN 56\" (1400MM) SWEEP, 5 Star Rating including cost of petty material required to complete the job in all respect. Make : ORIENT,HAVELLS ,CROMPTON | 86 | Each | |
| 395 | 4.94 | Supply, Installation, Testing and Commissioning and erection of Exhaust fan 300mm heavy duty 900 rpm complete with shutter (ISI mark) including cost of petty material required to complete the job in all respect. Make : ORIENT,HAVELLS ,CROMPTON | 111 | Each | |
| 396 | 4.95 | Supply, Installation, Testing and Commissioning, of Fresh Air Fan 250mm (10\") including cost of petty material required to complete the job in all respect. Make : ORIENT,HAVELLS ,CROMPTON | 2 | Each | |
| 397 | 4.96 | Supply, Installation, Testing and Commissioning, of wall fan 16\" ( 400 mm ) (ISI mark) including cost of petty material required to complete the job in all respect. Make : ORIENT, HAVELLS ,CROMPTON | 12 | Each | |
| 398 | 4.97 | Supply, erection, laying and testing of D.P. including the cost of krones, base plate, 40mm dia G.I. pipe for incoming and outgoing cable and main box having locking arrangement. 10pair DP | 1 | Each | |
| 399 | 4.98 | Supply & Erection of modular switch socket including connection & including modular plate and box etc.and other petty material required to complete the job up to entire satisfaction of Engineer - in - charge. Telephone socket outlet | 10 | Each | |
| 400 | 4.99 | TV antenna socket outlet | 5 | Each | |
| 401 | 5 | SITC 72 W LED Street Light. The Fixture should be Made of pressure diecast housing with TOUGHNED GLASS diffuser and indivisual LEDs with secondary optics with IP 66 protection. PF>.95, System Wattage LED 72W with Minium 3000 lumens in 5700k. The Fixture should be of Makes :-BAJAJ EDGE (169799 BRTFG 72W LED) /PHILIPS/GE/OSRAM/CGL/HAVELS | 30 | Each | |
| 402 | 5.01 | FEEDER PILLAR BOX Supplying , Installation, testing and commissioning of front and back openable, double door outdoor feeder pillar not less than 800 mm x 500mm x 300 mm depth fabricated out of M.S. sheet of thickness not less than 2 mm having inside door with cut out for operating accessories mounted after opening front and slanting top suitably over hang on all sides, ventilator louvers with wire mesh, earthing bus & stud base mounting angle frame of size 45 mm x 45 mm x 5 mm thick, and concrete / brick foundation cable entry knock out, locking arrangement, rubber gasket suitable for providing & fixing the following switch gear and accessories and 100 Amp TPN aluminium Busbar, including connection etc. as required. | 2 | Each | |
| 403 | 5.02 | A) Incomer : - | |||
| 404 | 5.03 | i) 60-100 AMP, 4 pole, 10 KA, MCCB i/c Rotary Handle( Similar to M/s Legrand DRX100) - 1 No. | |||
| 405 | 5.04 | B) Outgoing :- | |||
| 406 | 5.05 | i) 40 Amp 3P & N MCB 'C' Series - 3Nos. | |||
| 407 | 5.06 | ii)32A 3Pole contactors 3No Legrand CTX 40 | |||
| 408 | 5.07 | iii) Analogue 24hrs time switch ( Legrand cat no.Micro Rex QT31 daily) | |||
| 409 | 5.08 | iv) Danger notice plate - 1 set | |||
| 410 | 5.09 | v) Phase indicating lamp (R,Y,B) - 1 set | |||
| 411 | 5.1 | vi) 2.0mm thick FP with 100Amp,4 strip Alu Bus Bar ( 0.80 x 0.50) | |||
| 412 | 5.11 | vii) 45x45x5mm angle iron frame with CC foundation etc etc complete in all respect. | |||
| 413 | 5.12 | Supply & Erection of single bracket made of 40mm dia G.I pipe B class ISI 1.50mtr. Long with collar pipe (GI) 75mm dia 30cm Long top covered with ornamental cap duty welded painted 2coats of aluminum paints on bracket and golden paint of ornamental cap including the cost of labour and petty internal etc. complete in all respect up to the entire satisfaction | 30 | Each | |
| 414 | 5.13 | LIFTS - NON SCHEDULED ITEM | |||
| 415 | 5.14 | Supply Installation testing & commissioning of Passenger (884 Kg, 13 persons.) Machine Room Less Gearless Elevator with 3 year free comprehensivie warranty/maintenance period from the date of completion to be supplied and installed in accordance with the following technical specifications: \nMake:- OTIS/KONE/SHINDLER/JOHNSON/MITSUBISHI\n | 2 | Each | |
| 416 | 5.15 | Sr. No Description Specification (A)- IMonospace\n01) Designation of Lifts Passenger\n02) No. Of Elevators as shown in quantity coloum – Model – IMSS008 or equivalent\n03) Type and Capacity 13 Passenger – 884 Kgs\n04) Speed 1 M/Sec\n05) Drive V3F\n06) Location of M/c Room Not Required\n07) Travel 17 m approx.\n08) Serving , 0, 1,2,3 and 4\n09) No. Of Stops 5\n10) Well Size Available 1950 mm (W) x 2450 mm (D)\n11) Power Supply 415 V Three Phase 50 Cycles Ac\n12) Auxiliary Single Phase 220v 50 Cycles Ac\n13) Car size 1100 mm (W) X 2000 mm (D) X 2200 mm {H}\n14) Pit Depth 1500 mm\n15) Head Room 4200 mm | |||
| 417 | 5.16 | 16) Car Enclosure Model IMSS 008 or equivaltent\nCar Ceiling RL75 LED Lighting Ceiling\nCar Panels SS Hairline Finish Panels.\nCar Flooring Recess of 20mm will be provided. Flooring in\ncustomer scope.\nCar Illumination LED Lights.\n17) No. Of Entrance One Location Front\n18) Car Entrance Automatic Centre Opening Power Door in SS\nHairline Finish\n19) Door Safety Full Height Infra-Red Curtain.\n20) Landing Entrance Automatic Centre Opening Power Door in SS\nHairline Finish.\n21) Clear Opening 900mm (W) X 2000mm (H)\n22) Control Full Collective Simplex\n23) Indicators KDS 90 D & P indicators in White color\nCar KDS 90 Display & Position Indicators\nLanding KDS 90 Display & Position Indicators\n24) Handrail 01 on rear side. (S.S)\nOther Features\nFAN : 1 No. with 300 MM Sweep\nFlooring : Granite Flooring (Superior Quality CAT EYE or Equivalent) as per approved Design , duly approved by Engineer - in - charge\nLights : Diffused LED Lighting in car\nIndicaters : Digital Direction and Position Indicators in both car and at all landings, Call Registration: Red\nBattery Operated Emergency Light with Rechargeable Battery\nBattery Operated Emergency Alarm with Rechargeable Battery \nEmergency Alarm at the main building\nKDS 300 Square buttons\nMotor compatible for 180 starts per Hour\nDoor Open, door Close and alarm button in COP\nLanding doors fire rated for 01 Hour\nNudging\nPartial Height Mirror on rear wall\nFull Height car operating panel\nFacia plate\n2 Phase fireman drive, fireman's switch at the main landing. (In case fireman drive is activated the elevator will come to the main landing and open the door.)\nAdditional pressure sensing device\nLoad weighing device (Audio visual over load indicator in the car for better safety\nFull height Infra-Red curtian (Highly sensitive safety device for safe entrance & Exit of the passengers in to the car)\nPit ladder (Ensure safety of the maintenance personnel)\nEmergency light, intercom, and alarm with maintenance free rechargeable battery operation. (Ensure passenger comfort and safety in case of emergency)\n+6% to -10% Volt. Fluctuation withstand capacity (Ensure lift operation in low voltages)\nOver Speed Governer (Electo-Mechanical device that prevents free fall in case the elevator is travelling at speed more than 10% of the rated speed in downward direction)\nAutomatic rescue device with manual rescue lever (To rescue the passengers in case of emergency --- This device will bring the car to the nearest floor automatically and will open the doors. I.e it will resume operation from same floor.\nDaily automatic brake testing\nSteel Ropes (Ropes of Longer life and lower maintenance will be used)\nCar Door Lock ---Additional Safety Features | |||
| 418 | 5.17 | Supply Installation testing & commissioning of Passenger (1020 Kg, 15 persons.) Machine Room Less Gearless Elevator with 3 year free comprehensivie warranty period to be supplied and installed in accordance with the following technical specifications: \nMake:- OTIS/KONE/SHINDLER/JOHNSON/MITSUBISHI\n\n | 2 | Each | |
| 419 | 5.18 | Sr. No Description Specification (A)- IMonospace\n01) Designation of Lifts Passenger\n02) No. Of Elevators 01 – Model – IMSS008\n03) Type and Capacity 13 Passenger – 884 Kgs\n04) Speed 1 M/Sec\n05) Drive V3F\n06) Location of M/c Room Not Required\n07) Travel 17 m approx.\n08) Serving , 0, 1,2,3 and 4\n09) No. Of Stops 5\n10) Well Size Available 1950 mm (W) x 2450 mm (D) FINISHED All Side Brick\nWalls, Entrance Lintel and Sill should be in RCC at all\nlandings.\n11) Power Supply 415 V Three Phase 50 Cycles Ac\n12) Auxiliary Single Phase 220v 50 Cycles Ac\n13) Car size 1100 mm (W) X 2000 mm (D) X 2200 mm {H}\n14) Pit Depth 1500 mm\n15) Head Room 4200 mm | |||
| 420 | 5.19 | 16) Car Enclosure Model IMSS 008\nCar Ceiling RL75 LED Lighting Ceiling\nCar Panels SS Hairline Finish Panels.\nCar Flooring Recess of 20mm will be provided. Flooring in\ncustomer scope.\nCar Illumination LED Lights.\n17) No. Of Entrance One Location Front\n18) Car Entrance Automatic Centre Opening Power Door in SS\nHairline Finish\n19) Door Safety Full Height Infra-Red Curtain.\n20) Landing Entrance Automatic Centre Opening Power Door in SS\nHairline Finish.\n21) Clear Opening 900mm (W) X 2000mm (H)\n22) Control Full Collective Simplex\n23) Indicators KDS 90 D & P indicators in White color\nCar KDS 90 Display & Position Indicators\nLanding KDS 90 Display & Position Indicators\n24) Handrail 01 on rear side.\nOther Features\nFAN : 1 No. with 300 MM Sweep\nFlooring : Granite Flooring (Superior Quality CAT EYE or Equivalent) as per approved Design , duly approved by Engineer - in - charge\nLights : Diffused LED Lighting in car\nIndicaters : Digital Direction and Position Indicators in both car and at all landings, Call Registration: Red\nBattery Operated Emergency Light with Rechargeable Battery\nBattery Operated Emergency Alarm with Rechargeable Battery \nEmergency Alarm at the main building\nKDS 300 Square buttons\nMotor compatible for 180 starts per Hour\nDoor Open, door Close and alarm button in COP\nLanding doors fire rated for 01 Hour\nNudging\nPartial Height Mirror on rear wall\nFull Height car operating panel\nFacia plate\n2 Phase fireman drive, fireman's switch at the main landing. (In case fireman drive is activated the elevator will come to the main landing and open the door.)\nAdditional pressure sensing device\nLoad weighing device (Audio visual over load indicator in the car for better safety\nFull height Infra-Red curtian (Highly sensitive safety device for safe entrance & Exit of the passengers in to the car)\nPit ladder (Ensure safety of the maintenance personnel)\nEmergency light, intercom, and alarm with maintenance free rechargeable battery operation. (Ensure passenger comfort and safety in case of emergency)\n+6% to -10% Volt. Fluctuation withstand capacity (Ensure lift operation in low voltages)\nOver Speed Governer (Electo-Mechanical device that prevents free fall in case the elevator is travelling at speed more than 10% of the rated speed in downward direction)\nAutomatic rescue device with manual rescue lever (To rescue the passengers in case of emergency --- This device will bring the car to the nearest floor automatically and will open the doors. I.e it will resume operation from same floor.\nDaily automatic brake testing\nSteel Ropes (Ropes of Longer life and lower maintenance will be used)\nCar Door Lock ---Additional Safety Features | |||
| 421 | 5.2 | HVAC - NON SCHEDULED ITEMS | |||
| 422 | 5.21 | VARIABLE REFRIGERANT VOLUME / FLOW SYSTEM (With Heat Pump) Supply, Installation, testing and commissioning of air-cooled variable refrigerant flow modular type air-conditioning system with R410a refrigerant suitable for 415±10%, 50 cycles. The unit shall consist of indoor and out door units with individual controller as per detail given in specifications and having following items : (These items are to be given in Indian rupees with custom duties, inland freight, clearance, GST etc. FOR at Site basis) with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Quoted price shall also be inclusive of loading, unloading, lifting & shifting on terrace level or other suitable locations as per drawing, positioning charges besides including charges towards structural steel supports, MS base frame duly painted & vibration isolation arrangement etc. All compressors shall be inverter type. The condensing units shall be suitable to work on cooling as well as heating mode. The condensing units shall be suitable for operation on 415 ±10% volts, 50Hz, 3 phase AC power supply and complete with auto check function for connection error, auto address setting, etc. The outdoor units shall be low noise type. ODU tubes & fins shall be provided with anti erosion coating to prevent erosion. Quoted price shall be inclusive of Power Cable from MCCB to Outdoor unit & MS frame duly applied with 2 coat of primer & one coat of black enamel paint.. Quoted price shall be inclusive of power cable as required from TPN isolator to ODU. Modular type outdoor units equipped with highly efficient inverter type scroll compressors with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and Outdoor unitof following capacitites: Cost of R 410 A Gas should be inclusive The Vendor should considere the deration on ODU selection as per Hisar/NCR Ambient conditions. VRV/VRF ODUs shall be capable of operating in follwing range :\ni. For Cooling : (-)5 deg C to 50 deg C\nii. For Heating : (-)20 deg C to 15.5 deg C Outdoor Units-Heat Pump, Fully Gas Charged Make : Mitsubishi-Electric/ O General/ Tosiba- Premium/Daikin/Bluestar/LG | |||
| 423 | 5.22 | VRV/VRF : 84 HP ODU | 2 | No. | |
| 424 | 5.23 | VRV/VRF : 56 HP ODU | 14 | No. | |
| 425 | 5.24 | VRV/VRF : 44 HP ODU | 8 | No. | |
| 426 | 5.25 | Ductable Type indoor unit - VRV/VRF Supply, installation, testing and commissioning of ducable type indoor unit with corded/cordless remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete including corded/cordless remote with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Modular type indoor units comprising of EEV & all accessories as per the specifications. The indoor units shall be suitable to work on cooling as well as heating mode. The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply / 415 ±10% volts, 50Hz, 3 phase AC power supply. Ductable indoor units shall be suitable to handle extent of ductwork as shown in the design drawings and dehumidified air quantity as mentioned in the heat load summary sheet under \"Special Conditions\" and the indoor units shall be of following capacities. Quoted price shall be inclusive of Plug Top & necessary power cable. Make : Mitsubishi-Electric/ O General/ Tosiba- Premium/Daikin/Bluestar/LG | |||
| 427 | 5.26 | 1800 CFM / 5.0 TR | 4 | No. | |
| 428 | 5.27 | 2300 CFM / 6.0 TR | 4 | No. | |
| 429 | 5.28 | 3100 CFM / 8.0 TR | 12 | No. | |
| 430 | 5.29 | 4-way Cassette Type indoor unit - VRV/VRF Supply, installation, testing and commissioning of 4-way Cassette type indoor unit with cordless remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete including cordless remote with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Make : Mitsubishi-Electric/ O General/ Tosiba- Premium/Daikin/Bluestar/LG | |||
| 431 | 5.3 | 1095 CFM /4 TR | 2 | No. | |
| 432 | 5.31 | Wall Mounted Type indoor unit - VRV/VRF Supply, installation, testing and commissioning of Wall mounted type indoor unit with cordless remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete including cordless remote with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Make : Mitsubishi-Electric/ O General/ Tosiba- Premium/Daikin/Bluestar/LG | |||
| 433 | 5.32 | 448-296 CFM / 1.3TR | 66 | No. | |
| 434 | 5.33 | 500-322 CFM / 1.5TR | 118 | No. | |
| 435 | 5.34 | 582-480 CFM / 1.7TR | 86 | No. | |
| 436 | 5.35 | 647-488 CFM / 2.0TR | 164 | No. | |
| 437 | 5.36 | 875-560 CFM / 2.5TR | 20 | No. | |
| 438 | 5.37 | Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work (both for suction and discharge pipes will consist 1 unit) with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with Class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications.MS sleeves of requisite size shall be provided at wall crossing. Quoted price shall be inclusive of necessary glass cloth and minimum two layers of UV protection paint to be applied over insulation for all exposed pipes of approved make. Internal Refrigerant piping in exposed ceiling area & external refrigerant piping shall be laid on Ladder type cable trays. Cable trey used for external refrigerant piping shall be covered with cover. Referigerant piping shall be epoxy coated to prevent erosion. Piping shall be of following sizes : Make : Mandev/ Totaline/ Mexflow/ Parasmani | |||
| 439 | 5.38 | 50.8 mm OD | 450 | RM | |
| 440 | 5.39 | 44.5 mm OD | 430 | RM | |
| 441 | 5.4 | 41.3 mm OD | 500 | RM | |
| 442 | 5.41 | 38.1 mm OD | 470 | RM | |
| 443 | 5.42 | 34.9 mm OD | 266 | RM | |
| 444 | 5.43 | 31.4 mm OD | 300 | RM | |
| 445 | 5.44 | 28.6 mm OD | 444 | RM | |
| 446 | 5.45 | 25.4 mm OD | 580 | RM | |
| 447 | 5.46 | 22.2 mm OD | 226 | RM | |
| 448 | 5.47 | 19.1 mm OD | 2132 | RM | |
| 449 | 5.48 | 15.9 mm OD | 840 | RM | |
| 450 | 5.49 | 12.7 mm OD | 740 | RM | |
| 451 | 5.5 | 9.5 mm OD | 2132 | RM | |
| 452 | 5.51 | 6.4 mm OD | 532 | RM | |
| 453 | 5.52 | Supply, installation, testing and commissioning of imported refrigerant Y- joints/ headers in pair (1 No. for suction and 1 No. for discharge will be treated as 1 pair) with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Make : Mitsubishi-Electric/ O General/ Tosiba- Premium/Daikin/Bluestar/LG | 504 | Nos. | |
| 454 | 5.53 | CENTRALISED CONTROLLER Supply of main centralised controller as per specifications to hook up indoor units as mentioned above. Controller shall however, be suitable for minimum 64groups of indoor units & Outdoor Units. Centralised controller shall act as master controller for controlling of Heating -cooling mode of outdoor units and their associated indoor units. | 8 | Nos. | |
| 455 | 5.54 | Supply, Installation, Testing & Commissioning of Condensate Drain Pump with adequate Sump for Hi-wall units complete with water level sensor and accessories as required. Quoted price shall be inclusive of controller, NRVs & water sensors and associated wiring etc. to make installation complete. Drain Pump shall be suitable for operation on 220+6 % volts 50 Hz, 1phase AC power supply. Drain pumps shall automatically ON/Off based on water level. Drain pump for Hi-wall units | 454 | Nos. | |
| 456 | 5.55 | FACTORY FABRICATED DUCTING Supply , Installation and Testing of factory fabricated GSS ducting complete with vanes, splitter dampers, fire retardant gaskets hanging arrangement including fully threaded GI rods and GI \"C\" channels/ rolled steel wires or Gripple Wire Rope Hangers & Supports complete with end fixing, GI \"C\" channels etc. as approved by clients/consultants in accordance with the approved shop drawings and specifications. Quoted price shall be inclusive of necessary scaffolding charges towards installation of supply/exhaust air ducts outside or within building wherever required. Quoted price should also include necessary charges towards duct supporets including MS angle/channel arrangement as required for ducts being installed outside or within building wherever required. Spacing between duct supports should not exceed 2m in both cases i.e GI rods with GI \"C\" channels & Gripple Wire Rope Hanger support . In case of Gripple Wire Rope Hanger support for duct sizes above 1800mm, MS angles duly painted with black enamel paint should be used along with neoprene pad in between the duct & MS angle. All duct support to be provided with check nuts (lock nuts). While selecting the duct supports vendor shall ensure vibration free installation.Quoted price shall be inclusive of smoke test using smoke bombs. | |||
| 457 | 5.56 | 900mm to 1200mm -- 24G GSS with TDC Joints | 240 | SqM | |
| 458 | 5.57 | 1201mm to 1800mm - 22G GSS with TDC Joints | 800 | SqM | |
| 459 | 5.58 | FLEXIBLE CANVASS CONNECTIONS Supply, Installation, Testing of 125mm deep antivibration flexible joints at the outlet of air handling units/ductable split units//inline fans. Flexible connections shall be constructed using imported fire retardant fabric with extruded aluminium frame/flange on both sides of approved make. | 20 | No. | |
| 460 | 5.59 | LINEAR GRILLS Supply, Installation , Testing and Balancing of one way blow linear supply cum return air grilles complete with fixed core as per approved shop drawings and specifications. The grilles shall be of approved colour & shade. Powder coated aluminium grilles of extruded sections with integral flanges on both sides & ends as required complete with corner pieces. | |||
| 461 | 5.6 | 100/150/200/250 mm High grilles | 10 | SqM | |
| 462 | 5.61 | DOUBLE LOUVERED GRILLS Supply, Installation ,Testing and Balancing of double louvered supply air grilles as per approved shop drawings and specifications complete with key operated aluminium volume control dampers. Powder coated extruded aluminium grilles. | 5 | SqM | |
| 463 | 5.62 | AIR TRANSFER GRILLS Supply, Installation and Testing of extruded aluminium powder coated air transfer grilles | 2 | SqM | |
| 464 | 5.63 | SUPPLY AIR DIFFUSERS Supply, Installation, Testing and Balancing of square supply air diffusers with removable key operated volume control dampers with opposed blades as per the approved shop drawings and specifications.The diffusers shall be anti-smudge ring type/flat type as approved by the interior designer. Diffusers shall be with removable core for the following neck sizes. The diffusers shall be suitable for fixing in the gypsum/grid ceiling. The diffusers shall be of regular type. | |||
| 465 | 5.64 | Powder coated extruded aluminium diffusers of approved colour & shade. | 6 | SqM | |
| 466 | 5.65 | Supply, Installation and Testing of GI box type volume control dampers as per the specifications and shop drawings. | 6 | SqM | |
| 467 | 5.66 | Supply, Installation and Testing of GI multi blade type louver dampers as per the specifications and shop drawings. | 3 | SqM | |
| 468 | 5.67 | ACOUSTIC LINING OF DUCTS | |||
| 469 | 5.68 | Using Open Cell Nitirile Rubber with perforated aluminium foil covering | |||
| 470 | 5.69 | Supply and Application of internal acoustic lining of supply air ducting using open cell nitrile rubber insulation with density within 140-180 Kg/m3 as per the approved shop drawings and specifications. Insulation material shall be bonded with the ducts using metal screw and washers to facilitate grip to the GI sheet. | |||
| 471 | 5.7 | 25mm thick lining | 200 | SqM | |
| 472 | 5.71 | THERMAL INSULATION OF DUCTS (Class 'O' Fire Retardant Properties Closed Cell Elastomeric insulation) | 850 | SqM | |
| 473 | 5.72 | Supply and Application of external thermal insulation of supply /return air ducting using closed cell elastomeric nitrile rubber insulation with class 'O' fire retardant properties as per the specifications and drawings. | |||
| 474 | 5.73 | 13mm thick insulation | |||
| 475 | 5.74 | ASSOCIATED ELECTRICAL WORKS The rates for the distribution boards from the Breakers and instruments shall also include the following : | |||
| 476 | 5.75 | Wiring for light / Fan points with 1.5 sq. mm PVC insulated copper conductor 1100 Volt grade stranded flexible FRLS wires of approved make in 1.6 mm thick 25 mm dia MS conduit including cost of providing & fixing saddles, hangers, supports, cutting chases and filling chases for recessed conduiting, and including the cost of providing and fixing a 6 amp 240 Volt Modular Plate type switches of approved quality, colour, make and design with moulded cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sq. mm PVC insulated copper\nearth wire for loop earthing etc. complete | |||
| 477 | 5.76 | TPN ACB?s / MCCB?s shall mean 4 pole ACB?s / MCCB?s with adequate\nsize of neutral link. | |||
| 478 | 5.77 | All MCB?s shall be of minimum 25 KA breaking capacity. | |||
| 479 | 5.78 | The breaking capacity of MCCB?s are mentioned panel wise. All MCCB?s shall be with thermal magnetic microprocessor releases as per BOQ and following : | |||
| 480 | 5.79 | i. MCCB rating upto 250 Amps with thermal magnetic releases. | |||
| 481 | 5.8 | ii. MCCB above 250 Amps with microprocessor releases. | |||
| 482 | 5.81 | All MCB?s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic. | |||
| 483 | 5.82 | Degree of protection for following type of distribution panel enclosure\nshall be as per IS:13947-1993. | |||
| 484 | 5.83 | i. IP 42 for indoor panels. | |||
| 485 | 5.84 | ii. IP 55 for ODU panel. | |||
| 486 | 5.85 | All MCCB?s shall be provided with operating mechanism for door interlock. | |||
| 487 | 5.86 | All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. | |||
| 488 | 5.87 | Providing cable clamps / supports within distribution boards cable alley. | |||
| 489 | 5.88 | Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars. | |||
| 490 | 5.89 | Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. | |||
| 491 | 5.9 | All meter shall be digital type. | |||
| 492 | 5.91 | Current Transfomer shall be resin cast. | |||
| 493 | 5.92 | All Panel Shall be BMS Compitable | |||
| 494 | 5.93 | The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. | |||
| 495 | 5.94 | In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules. | |||
| 496 | 5.95 | ODU's Panel for one panel | |||
| 497 | 5.96 | Same as above item but outdoor Panel with following accessories. | |||
| 498 | 5.97 | INCOMING: | |||
| 499 | 5.98 | 1 No. 300 amps, 415V 4P MCCB with overcurrent and short circuit releases, all indication, push button etc. | |||
| 500 | 5.99 | Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set | |||
| 501 | 6 | (0 - 300 A) CT operated Ammeter with selector switch & 3 nos. CTs ratio 300/5A , 15VA burden & accuracy class of 1.0 - 1 set | |||
| 502 | 6.01 | 0-500 V Voltmeter with selector switch - 1 set | |||
| 503 | 6.02 | BUSBAR: | |||
| 504 | 6.03 | 300 Amp. TPN, 35 kA Al. Bus Bar | |||
| 505 | 6.04 | OUTGOINGS: | |||
| 506 | 6.05 | 125A, 4P ELCB with 18KA breaking capacity - 12 Nos. | |||
| 507 | 6.06 | ODU Panel Described as above/As per Manufacturer ODU Configuration. | |||
| 508 | 6.07 | Make : TELMOS HISAR / NEWTECH HISAR | |||
| 509 | 6.08 | Drain piping: Providing and fixing Polythene-Aluminimu-Polyethene (PE-AL-PE) Composite Pressure Pipes confirming to IS-15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80 C , including all special fittings of composite material(engineering,plastic blend and brass inserts wherever required) e.g. elbow, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing. This includes testing of joints complete as per direction of the Engineer-in-Charge and with the 3 years free comprehensive\nwarranty period. Make: KiTEC ISI marked or equivalent. | |||
| 510 | 6.09 | 25mm outer dia | 666 | Rmt | |
| 511 | 6.1 | 32mm outer dia | 888 | Rmt | |
| 512 | 6.11 | 40mm outer dia | 444 | Rmt | |
| 513 | 6.12 | 50mm outer dia | 222 | Rmt | |
| 514 | 6.13 | Supply erection testing & commissioning of 2 core 1.5 sqmm shielded copper control wire from outdoor unit to indoor units including the cost of all petty materials required to complete the job unto the entire satisfaction of Engineer-in-charge. Transmission wiring to be laid in MS conduits between indoor units and their wired remotes. | 6000 | Mtr. | |
| 515 | 6.14 | KITCHEN VENTILATION | |||
| 516 | 6.15 | Double Skin Air Washer Units :-Supply, Installation, Testing and commissioning of sheet metal sectionalized construction Double skin Air Washer Unit, each complete with Blower section, Wet section and filter section as detailed in the specifications and complete with forward curved DIDW Blower with TEFC 4 Pole motor, belt drive package, vibration isolation pads - spring mounted, 50 mm thick pre filters, monobloc pump etc. complete as per specifications and as mentioned in the schedule of equipment of following capacities. AWU 10000 CFM 55 mm static (floor mounted) For Main Kitchen Make: Edgetech / Zeco / Blowtech / Waves | 2 | EACH | |
| 517 | 6.16 | EXHAUST AIR SCRUBBER:- Supply, Installation, Testing and Commissioning of Scrubber each comprising of extract air intake section, wet type air cleaner to remove oil, smoke and fumes from exhaust air, as per the Specifications. The pump shall be placed inside the wet scrubber with float. 12000 CFM 65 mm static For Main Kitchen. Make: Edgetech / Zeco / Blowtech / Waves | 2 | EACH | |
| 518 | 6.17 | Supply, installation, testing and commissioning of factory fabricated sheet metal ducting complete with supports, dampers etc. as per IS 655 and approved drawing and as per specifications of below gauges: 24 Gauge Make: Tata / Sail / Nippon / JSW | 500 | SQM | |
| 519 | 6.18 | 22 Gauge | 700 | SQM | |
| 520 | 6.19 | 20 Gauge | 100 | SQM | |
| 521 | 6.2 | Supply, fabrication, installation and testing the flexible connections constructed of fire resistance flexible double canvas sleeve as per the approved shop drawings. Make: Tata / Sail / Nippon / JSW | 4 | SQM | |
| 522 | 6.21 | Supply, installation and testing of GI construction Louver dampers within ducts to be provided with suitable ducts lever and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system. Make: Tata / Sail / Nippon / JSW | 4 | SQM | |
| 523 | 6.22 | Fire Damper with Control Mechanism- Supplying, fixing, testing and commissioning of motor actuated Fire Dampers of at least 1.5 hour fire rating in supply air duct at wall crossing of AHU room/as and where required, of requires sizes including control wiring. The damper shall be motorized and spring return so as to close the damper in the event of a fire signal which shall be provided by smoke sensor/detector in AHU room as per specifications and as required. The spring return action shall be in-built mechanism and not externally mounted. The control wiring shall be interlocked ion such a way that along with actuation of damper-closing mechanism, the AHU fan motor gets automatically switched off. Fire damper as described above, as per specifications and complete in all respects. Make: Caryaire / Ravistar / Air Control | 8 | SQM | |
| 524 | 6.23 | Electric Actuator:- Electric actuator with necessary linkage to actuate fire dampers complete with required wiring and associated accessories.Note: Fire dampers shall be supplied with sensors/actuators/control etc duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper. Make: Caryaire / Ravistar / Air Control | 4 | EACH | |
| 525 | 6.24 | Supply, installation, testing and balancing of powder coated Extruded Aluminum supply air Grilles with aluminum volume control dampers as per specifications Make: Caryaire / Ravistar / Air Control | 10 | SQM | |
| 526 | 6.25 | Supply, installation, testing and balancing of powder coated Extruded Aluminum supply air Grilles without volume control dampers as per specifications Make: Caryaire / Ravistar / Air Control | 14 | SQM | |
| 527 | 6.26 | Isolator:-Providing & fixing weather proof isolator near each outdoor unit. Capacity 32Amp/40 Amps 3 Phase. Make: Schneider / Legrand / Havells / L &T | 4 | EACH | |
| 528 | 6.27 | Panel for Air washer/ Exhaust unit :- Design, manufacture, supply, installation, testing and commissioning of the following cubicle type DOUBLE DOOR, dead front, sheet steel, wall mounted control panels, sleeve type aluminium bus bars including anchoring into the wall shall be provided by the Contractor.All internal wiring and GI earthing of ventilation unit motors from the panel shall be included. The panel shall include the following accessories.TPN MPCB for incoming power as per rating given below,Terminal block for power distribution.Single phase preventer.Phase indicating lights and indicating light for 'ON' status with toggle switches and back-up fuses.96 mm x 96mm voltmeter with fuse of suitable range.Ammeter of suitable range with CTs and selector switch. Time delay relay for delayed automatic restart of Ventilation unit motor.220/24 volts transformer.24 volts wiring to the 2-way diverting valve and space thermostat.Wiring for micro-switch smoke sensor and electric actuator for stopping the fan when smoke/fire damper closes (For units provided with fire damper).Control wiring for thermostat.ON/OFF push buttons with toggle switch for remote start/stop and indicating light for 'ON' status at CONTROL DESK.Bimetallic lugs shall be used at copper to aluminium joints.Auto/Manual start/stop selector switch shall be provided for each equipment in the panel to facilitate remote operation from Central Indication Light Panel. Panels shall have adequate space for mounting transformers and other accessories related to control system.Incomer,80 A MCCB, TPN, 10 KA with Voltmeter & ammeter of suitable range with selector switches along with CTs, one set of RYB phase indicating lamps.Outgoings feeders:3 nos. of starter for Ventilation Units (One as Spare) Make: Schneider / Legrand / Havells / L &T | 2 | EACH | |
| 529 | 6.28 | LANDSCAPING - NON SCHEDULED ITEMS | |||
| 530 | 6.29 | Supplying at site of work De - oiled Neem-Cake duly packed in used gunny bags. | 9.78 | Qtl | |
| 531 | 6.3 | Providing and stacking of Terminalia Mantly of height 244-305 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. | 70 | Each | |
| 532 | 6.31 | Providing and stacking of Schleichera trijuga (Kusum) of height 244-305 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. | 34 | Each | |
| 533 | 6.32 | Providing and stacking of Washingtonia Palm of height 213-244cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. | 28 | Each | |
| 534 | 6.33 | Providing and Displaying Bismarckia Palm 152 to 183 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. | 64 | Each | |
| 535 | 6.34 | Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 244-305 cm. in Big HDPE Bag as per direction of the officer-in-charge. | 22 | Each | |
| 536 | 6.35 | Providing and stacking of Plumeria alba of height 244-305 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. | 184 | Each | |
| 537 | 6.36 | Providing and stacking of Conocarpusof height 152-183 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. | 204 | Each | |
| 538 | 6.37 | Providing and stacking of Allamanda Pinkof height 61-92 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. | 256 | Each | |
| 539 | 6.38 | Providing and stacking of Chorisia speciosa of height 244-305 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. | 12 | Each | |
| 540 | 6.39 | Providing and stacking of shrubs and flowers of height 15- 20 cm in poly bags of size 25 cm as per direction of the officer -in -charge. | 10000 | Each | |
| 541 | 6.4 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same and\nmaintenance for 30 days or more till the grass establish properly, as per direction of the officer in charge (DSR 2.34 Holticulturaul) | 14287.2 | Sqm | |
| 542 | 6.41 | FIRE FIGHTING - NON SCHEDULED ITEMS | |||
| 543 | 6.42 | Electric Fire Pump (Underground) \nSupplying, installation, testing and commissioning of electric driven underground main electrical pump suitable for automatic operation and consisting of following, complete in all respects, as required: \n(a) Horizontal type, Single stage end suction, centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft, mechanicalseal confirming to IS : 1520\nb) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure,horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325.\n(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.\n(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.2850 lpm at 70 m Head (DSR AOR FIRE 1.2) | 2 | EACH | |
| 544 | 6.43 | Jockey Pump Horizontal type, Single stage end suction, centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft, mechanicalseal confirming to IS : 1520\nb) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.\n(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.\n(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.180 lpm at 70 m Head (DSR AOR FIRE 3.2) | 2 | EACH | |
| 545 | 6.44 | Diseal Pump Horizontal type, Single stage end suction, centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft, mechanicalseal confirming to IS : 1520\nb) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.\n(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.\n(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.2850 lpm at 70 m Head (DSR AOR FIRE 2.2) | 2 | EACH | |
| 546 | 6.45 | Electric Fire Booster Pump (Terrace):\nSupplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)\n(a) Horizontal type, Single stage end suction, centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft, mechanicalseal confirming to IS : 1520\nb) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.\n(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.\n(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.900 lpm at 35 m Head (DSR AOR FIRE 4.1) | 4 | EACH | |
| 547 | 6.46 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 200 mm. Dia (DSR AOR FIRE 6.1) | 24 | METRE | |
| 548 | 6.47 | 150mm DIA (DSR AOR FIRE 6.2) | 240 | METRE | |
| 549 | 6.48 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.150 mm dia (DSR AOR FIRE 7.8) | 948 | METRE | |
| 550 | 6.49 | 100mm DIA (DSR AOR FIRE 7.7) | 120 | METRE | |
| 551 | 6.5 | 80mm DIA (DSR AOR FIRE 7.6) | 72 | METRE | |
| 552 | 6.51 | 25mm DIA (DSR AOR FIRE 7.1) | 36 | METRE | |
| 553 | 6.52 | Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Stainless Steel cap and chain as required :Single headed Stainless Steel (DSR AOR FIRE 9.2) | 80 | EACH | |
| 554 | 6.53 | Hose cabinet made of 16 SWG M.S sheet with glass front door - complete with hinges, handle, locking arrangement, recessed key provision and painting. The size shall be 750mm x 600mm x 250mm to accommodate 2 Nos. of hoses of length 15 m long, one branch pipes with nozzle with necessary clamps | 80 | EACH | |
| 555 | 6.54 | Fire Man's Axe | 52 | EACH | |
| 556 | 6.55 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :SS type (DSR AOR FIRE 16.2) | 160 | EACH | |
| 557 | 6.56 | Supplying & fixing 63 mm dia Stainless Steel type short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :SS type (DSR AOR FIRE 18.2) | 80 | EACH | |
| 558 | 6.57 | Stainless Steel chrome finished Ball valves with fittings of screwed end type. 25 mm | 66 | EACH | |
| 559 | 6.58 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia stainless steel globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop Stainless steel valve & M.S. Pipe and socket. 40M (DSR AOR FIRE 17.2) | 52 | EACH | |
| 560 | 6.59 | Supplying and fixing of fire brigade connection of cast iron body with SS type male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :4 way - 150 mm dia M.S. Pipe (DSR AOR FIRE 19.2) | 8 | EACH | |
| 561 | 6.6 | Supplying and fixing air vessel made of 400 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Stainless steel type wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. (DSR AOR FIRE 20) | 2 | EACH | |
| 562 | 6.61 | Pressure gauge of suitable range shall be installed on the discharge side of each pump The dial size shall be 250 mm. The gauges shall have brass cocks. (0 to 15 Kg/sq.cm). 25 MM | 70 | EACH | |
| 563 | 6.62 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required (DSR AOR FIRE 22) | 10 | EACH | |
| 564 | 6.63 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/SS type seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 MM (DSR AOR FIRE 11.5) | 18 | EACH | |
| 565 | 6.64 | 150mm (DSR AOR FIRE 11.6) | 20 | EACH | |
| 566 | 6.65 | 80mm (DSR AOR FIRE 11.4) | 28 | EACH | |
| 567 | 6.66 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 MM DIA (DSR AOR FIRE 15.2) | 6 | EACH | |
| 568 | 6.67 | 150mm (DSR AOR FIRE 15.2) | 4 | EACH | |
| 569 | 6.68 | Foot valve 100 mm dia | 8 | EACH | |
| 570 | 6.69 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:\n5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 MM (DSR AOR FIRE 14.5) | 10 | EACH | |
| 571 | 6.7 | 150mm (DSR AOR FIRE 14.7) | 12 | EACH | |
| 572 | 6.71 | Rubber Expansion bellows (PN 1.6) with required flanges and fasteners for fire Pumps. 100mm dia | 8 | EACH | |
| 573 | 6.72 | Air cushion 200mm dia, 2000 mm long 8mm thick steel to withstand pressure with dished ends and supporting legs with 25mm inlet, 25mm drain, 25 mm dia connection for air release valve including legs, painting with red oxide primer and finished with fire red enamel paint. It shall be inclusive of all relevant pipes, valves, specials upto pumpheader and other accessories as per local fire brigade standard. 200mm dia | 4 | EACH | |
| 574 | 6.73 | Stainless steel type Air release valve - 25mm dia with globe valve. 25mm dia | 12 | EACH | |
| 575 | 6.74 | Supply, installation, testing and commissioning of fire control panel metal clad type suitable for 415 V AC three phase 4 wire 50Hz supply system. The panel shall be suitable for automatic operation of the fire pumps as per the specified parameters. The panel shall be completely compartmentalised and complete with relays, contactors, starters, Aluminium Bus Bars, designation labels as per requirement, continuous earth bar, panel separators, protective screens, cable clamping support system, top/bottom cable gland plates for incoming and out going cable entries as per details given below:INCOMING 315A 35KA TPN MCCB with rotary handles - 1 No. BUSBARS A set of 400A 415V 50Hz 3 Ph 4 wire aluminium busbars. INSTRUMENTS INCOMER A set of instrumentation with a set of Current transformer 315/5A with Ammeter 0-315A, Selector Switch, Voltmeter 0-500V with selector switch and a set of phase-RYB indicating lights with MCB and energy meter. Provision for BMS connectivity. The panel should have sufficient no. of potential free contacts for connectivity with Building Management System for monitoring purposes INSTRUMENTS ON OUTGOINGS-A set of instrumentation with ammeter with selector switch and current transformer each pump.Indication lights for ON-OFF indication for each fire pump. OUTGOING FEEDERS,For Hydrant Pump -160A TP 35 KA MCCB with phase spreader with rotary handle, 60HP DOL starter, overload relay, single phase preventer, timer etc. - 1 No.For Jockey Pump -63A TP 25KA MCCB with rotary handle, 10 HP DOL starter, overload relay, single phase preventer, timer etc. - 2 No.For Diesel Engine Operated Pump,AMF logic control for auto starting of the diesel engine operated pump when the electric driven pumps fail to start. The control cubicle shall consist of MCBs, 12/24V battery charger, DC ammeter and voltmeters , indicating lights , push buttons, hooter, lockout timers, interlocking relay, fuel level indicators etc. as required.Control wiring, auxiliary switches and timer for automatic starting and stopping of Jockey and electric driven pump with externally mounted pressure switches. The control wiring shall be done in such a way that the Jockey pump shall start when the pressure falls to 6.0 Kg/sq.cm and stops at 7.0 Kg/sq.cm pressure and Main fire pump shall start when the pressure drops below 5.0 Kg/sq.cm. and stops when the pressure builds above 7.0 Kg/sq.cm. Jockey pump shall stop when the main pump is working. Suitable timers shall be used for starting and stoping of the pumps operation. | 2 | EACH | |
| 576 | 6.75 | FIRE DETECTION AND FIRE ALARM - NON SCHEDULED ITEMS: | |||
| 577 | 6.76 | Supply Installation and Commissioning of UL Listed and FM approved 4 Loop Analog addressable Fire Alarm system , having the total panel capacity of 504 devices (detector or device any combination). The panel shall have a backlit, 2”-x- 4.3/4” backlit LCD screen and the four-way navigation push button at the top of the FACP. The panel shall have the capacity of storing upto 5000 events. The panel shall have Multiple levels of password protection, Automatic environmentalbe compensation for smoke detectors, Degrade-mode operation, polarity-insensitive detection circuits, Supports single-person Walk Test, Connectivity to a leased-line / city-tie module, The Panel shall disconnect backup battery on the addressable FACP when its voltage drops below 19VDC. The panel shall have a built in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries upto 33 AH. The panel shall have 240 V AC power supply, 24 V SMF batteries sufficient for 24 hour in standby and 30 minutes in alarm complete as per specification. The Panel shall have the capacity of connecting additional 15 panels or Network terminals, with redundancy in the network. The panel shall have the capacity of connecting maximum 8 Remote terminals or 8 remote displays. The panel shall be approved by UL 864 9th Edition Listed, ULC, FM, CSFM & NYC Fire Department with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell (a) Main Fire Alarm Control Panel 4 Loop (To Be placed in Server Room) | 2 | Nos | |
| 578 | 6.77 | Supply Installation and Commissioning of UL listed and FM approved Intelligent Addressable Multicriteria Smoke detector having responsiveness of photoelectric, thermal (Rate-of-Rise and Fixed), ionization technology and false alarm resistance along with standard base. The detector shall be Polarity insensitive, dust-resistant photoelectric chamber, Automatic environment compensation, field programmable as rate-of-rise or fixed temperature. The detector shall have Tri-color detector-status light-emitting diode (LED) with 360° view. The detector shall be approved by UL, ULC, FM, CSFM & NYC Fire Department. with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 588 | Nos. | |
| 579 | 6.78 | Supply Installation Testing and Commissioning of FAULT ISOLATOR Operating voltage 15 – 32 VDC (peak)\nMaximum current upon\nactivation due to short circuit Refer to the manual for the main FACP\nStandby current 450 µA maximum; \nthrough a closed relay\nTemperature range 32°F to 120°F (0°C to 49°C)\nRelative humidity 10% to 93%\nWeight 5 oz. (150 grams)\nDimensions 4.5”H x 4.5”W x 0.25” D (11.43 cm H . Complied : Compliant by UL/VDS/ with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 40 | Nos | |
| 580 | 6.79 | Supply Installation and Commissioning of UL listed and FM approved single action Manual Pull Station. MCP Shall be Polarity insensitive, shock and vibration resistant. MCP shall be approved by UL, ULC, FM, CSFM & NYC Fire Department with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 60 | Nos | |
| 581 | 6.8 | Supply Installation Testing and commissioning of addressable Hooter Cum Sounder with Following features Specification:\nOperating voltage : 17-27V DC\nQuiescent current : 1mA Sound Level : 90dB at 3Mtr\nAlarm current : 30mA\nOperating temperature : 0ºC to 49ºC \nHumidity : 0-95% RH (Non-condensing)\nColor : RED\nDimensions with Back Box & weight : 86x86x25mm , 62g Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 60 | Nos. | |
| 582 | 6.81 | Supply, Installation, Testing and commissioning of IEC 60849 Approved Glow Type EXIT/Stair /Emergency Exit Sign Board as finalized by Engineer In Charge, on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastenerwith 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: PES/HEINRICH/OMEX/COOPER | 60 | Nos. | |
| 583 | 6.82 | Supply Installation and Commissioning of Networkable Fire alarm repeater panel. panel front-end has a interactive display with touch screen control and monitor the emergency events . system works on 24V DC. Panel has built in 230V to 24V power supply unit. This unit has built in battery charger and provision for SMF battery. Panel having the following specification Specification:\n Primary Power : 110V/220V±10% AC, 60/50Hz\nStandby Power : 24V DC(12V, 7Ah SLA Battery,2Nos) \nCharging Voltage : 28 ± 1V\nCharging Current : 330mA (max)\nOperating Temperature : 0° C to 49° C Complied : UL Certified Complied : Compliant by UL/VDS/ with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 2 | Nos | |
| 584 | 6.83 | Supply Installation Testing and commissioning of addressable Monitor Module with Following features Specification:\nOperating voltage : 17-27V DC\nQuiescent current : 600uA \nAlarm current : 1mA\nOperating temperature : 0ºC to 49ºC \nHumidity : 0-95% RH (Non-condensing)\nColor : White\nDimensions with Back Box & weight : 106x108x38mm , 372g Certified Complied : Compliant by UL/VDS/ with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 20 | Nos | |
| 585 | 6.84 | Supply Installation Testing and commissioning of addressable Control Module with Following features Specification:\nOperating voltage : 17-27V DC\nQuiescent current : 600uA \nAlarm current : 18mA Relay contact Rating : 2A @ 24V DC\nOperating temperature : 0ºC to 49ºC \nHumidity : 0-95% RH (Non-condensing)\nColor : White\nDimensions with Back Box & weight : 106x108x38mm , 372g Certified Complied : Compliant by UL/VDS/ with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 20 | Nos | |
| 586 | 6.85 | Supply, Installation, Testing and commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be compliant to EN54/UL/VDS. with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 20 | Nos | |
| 587 | 6.86 | Supply, Installation, Testing and commissioning of SITC of minimum 1000 mtr. Range (Kheraj make) SIREN generator provided at the roof of the building with separate power supply, relay etc with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 2 | Nos | |
| 588 | 6.87 | Supply & erection of Duct type smoke detector with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cerberus by Siemens / Schrack / Notifier / Edward/ Honeywell | 10 | Nos | |
| 589 | 6.88 | Supply, installation, testing and commissioning of 2 core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc. including the cost of all petty material required to complete the job upto entire specifications of Engineer-in - charge and with the 3 years free comprehensive warranty period. Make : Polycab/Havells/ Finolex | 12000 | Mtr | |
| 590 | 6.89 | Supply, installation, testing and commissioning of controller Digital Voice Evacuation system with built in Amplifier. The System shall meet the standards of BS EN54 - 32 & EN 60849. The System Shall have Built in 500W Class-D Amplifier and it should be capable for the EVAC, Paging, PA and BGM functions. The Controller shall have SD card option to store the EVAC and Alert Voice Message. The Controller shall have Speaker line supervision and amplifier auto changeover. The Controller shall have following features: Seperate Zone volume control at the front side of panel, Status indications on the Panel for EVAC,Fault ,AC,DC ,Fault,ALERT & Fireman mic, Zone capacity up to 96 Zones, 6 programmable Control Input and output, Fireman Microphone with High Priority, THD<1%, Frequency response 80Hz - 20kHz, Up to 1000 Record files, 100V Class-AB Speaker Output. Complete with EN54 Approved with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer-in-Charge. Make:- HEINRICH/ASL/BOSE | 2 | Nos | |
| 591 | 6.9 | Supply, installation, testing and commissioning of 20 Watt BI Directional speaker Rated power : 20W/10W/5W, Sound pressure Level at rated power 20W/1w (at 1kHz ,1m): 104 dB/95dB , Effective range (-10 dB ): 100-20000 Hz, Speaker Driver 5\" x 2, IP Rated 66, Rated Voltage : 100 V with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer-in-Charge. Make:- HONEYWELL /ASL/BOSE/JBL | 130 | Nos | |
| 592 | 6.91 | Supply, installation, testing and commissioning of 240W RMS Single Channel Power Amplifier with Switch power technology for power electricity saving, Separate PFC Design for highest reliability, Separate Power Supply System. Amplifier shall have Following Features: 240W RMS per Channel, Amplifier Output 100V and 70V , Supply input AC 220 +/- 10% - 50/60Hz, Short Circuit, Power, Temperature, Overload Protection, Auto Cooling Fans. THD <0.1%, Frequency Response 60Hz - 15kHz, AC & DC Fuse, SNR >70dB. with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer-in-Charge. Make:- HEINRICH/ASL/BOSE | 10 | Nos | |
| 593 | 6.92 | Supply, installation, testing and commissioning of BGM Source unit for background music DVD/CD-player for video and audio Supports MP3, JPEG, and multiformat video outputs AM/FM tuner with 10 presets and digital control Simultaneous operation of-player and tuner With Remote control with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer-in-Charge. Make:- HEINRICH/ASL/BOSE | 2 | Nos | |
| 594 | 6.93 | Supply, installation, testing and commissioning of Digital Voice Evacuation remote paging microphone 6- zone call station, Six zone selection keys, all-call key and momentary PTT-key for calls with 6 Zone capacity. The Microphone shall have Reset/Cancel, All Call & Call Buttons. CAT6 Cable Communication up to 600 meter. Built in Monitor Speaker and DIP Switches to set up ID and Priorities. with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer-in-Charge. Make:- HONEYWELL /ASL/BOSE/JBL | 2 | Nos | |
| 595 | 6.94 | Supply installation testing & commissioning of 42U server rack with accessories with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer-in-Charge. Make:- HONEYWELL /ASL/BOSE/JBL SITC of STRUCTERED CABLING SYSTEM (SCS) | 2 | Nos | |
| 596 | 6.95 | ACTIVE NETWORK - EQUIPMENT - NON SCHEDULED ITEMS | |||
| 597 | 6.96 | Supply, Installation, Testing & Commissioning of Core Switch, Should support at least 24 x100/1000X SFP port with min 8 x100/1000 T ports. Min 4 x 10 G Based SFP+ port should be ready from day 1 . The switch should be scalable to min 2 x QSFP+ port .The switch should have min 40 gbps stacking bandwidth and the stacking could be achieved over geographically diversified location as min over 2 Kilometers, Switches must be managed Basic layer-3 type for better broadcast segmentation, Non-blocking architecture, At least 290Gbps switching bandwidth, Throughput 220 Mpps or more for each member switch complete with all labour and accessories upto the entire satisfaction of Engineer In Charge.\nMake: Cisco/NETGEAR/ALLIED TELESYS Networks/ EXPREME | 2 | Nos | |
| 598 | 6.97 | Supply, Installation, Testing & Commissioning of 24 Port Access Switch PoE, Should support at least 24 x10/100/1000T port with min 8 x1G SFP ports. Min 2x SFP+(10) port should be Ready from day 1. Min 2 Stacking port should be ready from day 1 (40 Gbps stacking bandwidth support) .. Geographically stacking should be achieved if required for ease of management. In support for 370 Watt PoE + /PoE power budget . Existing 4x1G SFP port should be upgradable to 4*10G SFP+ in future in same hardware complete with all labour and accessories upto the entire satisfaction of Engineer In Charge.\nMake: Cisco / NETGEAR / ALLIED TELESYS/EXPREME | 20 | Nos | |
| 599 | 6.98 | Supply, Installation, Testing & Commissioning of 24 Port Access Switch Non PoE, Should support at least 24 x10/100/1000T port with min 8 x1G SFP ports. Min 2x SFP+(10) port should be Ready from day 1. Min 2 Stacking port should be ready from day 1 (40 Gbps stacking bandwidth support) . Geographically stacking should be achieved if required for ease of management complete with all labour and accessories upto the entire satisfaction of Engineer In Charge.\nMake: Cisco / NETGEAR / ALLIED TELESYS/EXPREME | 20 | Nos | |
| 600 | 6.99 | Supply, Installation, Testing & Commissioning of A P Indoore, Access Points proposed must include radios for 2.4 GHz and 5 GHz with 802.11ac, Should support 2.9 Gbps data rates on dual concurrent radio operations, AP shuoild support layer 2 and Layer 3. Layer 3 Routing.802.1q,DNS,DHCP Server/Client,Bootp client,PPPoE,LLDP complete with all labour and accessories upto the entire satisfaction of Engineer In Charge.\nMake: Cisco/ALLIED TELESYS Networks/EXPREME | 60 | Nos | |
| 601 | 7 | Supply, Installation, Testing & Commissioning of Wireless Controller, WLAN Controller should be Hardware, As Per technical Specification, It should have minimum 4x1000Base-T interfaces or more from day 1, appliance 1U Rack mountable. It should be supplied 75 AP licenses for the campus from Day 1, Controller shall be capable of supporting 500 AP’s with license upgradeability and should support minimum 16K Clients from day 1 complete with all labour and accessories upto the entire satisfaction of Engineer In Charge.\nMake: Cisco/ALLIED TELESYS Networks/EXPREME | 2 | Nos | |
| 602 | 7.01 | Supply Installation testing & commissioning of 1 GE Direct Attached QSFP+ to QSFP+ Active Cupper cable, 1m, with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. Make: Cisco/ALLIED TELESYS Network/EXPREME | 40 | Nos | |
| 603 | 7.02 | Supply Installation testing & commissioning of 10GBASE-LR4 QSFP+ optic (LC) For up to 10Km over SMF with the 3 years comprehensive NBD and 24x7 direct OEM TAC Support including cost of petty material Make: Cisco/ALLIED TELESYS Network/EXPREME | 4 | Nos | |
| 604 | 7.03 | PASSIVE NETWORK-EQUIPMENT - NON SCHEDULED ITEMS | |||
| 605 | 7.04 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ ROHS complied and U/L listed EC Verified to ISO 11801 IEC 60332-1 EN 50173-1 TIA/EIA 568A in accordance with NFC 32062 with flame retardant effect & NFC 32070. The cable NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT test result should meet & exceed the performance requirement as per ANSI/TIA 568C.2.\nMake & Model: LEGRAND / PANDUIT / 3C3 | 52500 | Mtr | |
| 606 | 7.05 | Supplying, installing, testing and commissioning of 24 port Cat 6 patch panels available with block of four equipped with tool less IO, Rack Mountable. 19\" Modular Patch Panel, loaded CAT6 U/UTP 24 port LCS2 rack mountable to be compatible in 4nos of 6 X RJ 45 Tool less connector U/UTP unit in a block complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer -in-charge of work.\nMake & Model: LEGRAND / PANDUIT / 3C3 | 40 | Nos | |
| 607 | 7.06 | Supplying, installing, testing and commissioning of Cat 6 , Tool less Information outlet for Voice. Cat6 U/UTP built in crimping hands-free, minimum 5 times reconnection possibilities. LCS2 Toolless RJ45 Information outlet where insertion test (in & out) must be 2500 times (I/O) along with front side Label holded and transparent shutter for category white in colour, including front plate and anodised GI box in concealed manner of adequate sizes,including all fixing accessories complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer -in-charge of work..\nMake & Model: LEGRAND / PANDUIT / SIEMON | 620 | Nos | |
| 608 | 7.07 | Supplying and fixing following Modular base & cover plate including modular metal boxes etc. as required.\n1 or 2 Module Face Plate complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer -in-charge of work.\nMake & Model: LEGRAND / PANDUIT / 3C3 | 540 | Nos | |
| 609 | 7.08 | Supplying, installing, testing and commissioning of following length of Cat - 6 patch cord. 4 Feet : CAT6 UTP 23 AWG Patch Cord - 1 mtr - Rack End. Factory crimped LCS2 Patch cord in Blue colour. \nMake & Model: LEGRAND / PANDUIT / 3C3 | 950 | Nos | |
| 610 | 7.09 | Supplying, installing, testing and commissioning of following length of Cat - 6 patch cord. 7 Feet : CAT6 UTP 23 AWG Patch Cord - 2 mtr - Rack End. Factory crimped LCS2 Patch cord in Blue colour. \nMake & Model: LEGRAND / PANDUIT / 3C3 | 600 | Nos | |
| 611 | 7.1 | Supplying and fixing of PVC Cable Manager finger duct type\nMake : Standard | 80 | Nos | |
| 612 | 7.11 | Supply Installation Testing & Commissioning of 6 core mm fibre cable (per meter) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer - in - charge of work.\nMake & Model: LEGRAND / PANDUIT / 3C3 | 1200 | Mtr | |
| 613 | 7.12 | Supply Installation Testing & Commissioning of 12 core mm fibre cable (per meter) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer - in - charge of work.\nMake & Model: LEGRAND / PANDUIT / 3C3 | 200 | Mtr | |
| 614 | 7.13 | Supply Installation Testing & Commissioning of 12 port fibre LIU Loaded complete with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer - in - charge of work.\nMake & Model: LEGRAND / PANDUIT / 3C3 | 18 | Mtr | |
| 615 | 7.14 | Supply Installation Testing & Commissioning of 24 port fibre LIU Loaded complete with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer - in - charge of work.\nMake & Model: LEGRAND / PANDUIT / 3C3 | 2 | Nos | |
| 616 | 7.15 | Supply Installation Testing & Commissioning of 3 Mtr fibre Patch Cord complete with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer - in - charge of work.\nMake & Model: LEGRAND / PANDUIT / 3C3 | 40 | Nos | |
| 617 | 7.16 | SITC of 42RU, 800w x 1000d, 19\" Comms equipment rack with front 19\" rails and dual 12-outlet PDUs, and mesh-screen front and rear lockable doors, ventilated top cover with cable glands.\nMake: Valrack/Emerson/HiveNetwork/GADAN | 2 | Nos | |
| 618 | 7.17 | SITC of 15RU, 800w x lOOOd, 19\" Comms equipment rack with front 19\" rails and dual 12-outlet PDUs, and mesh-screen front and rear lockable doors, ventilated top cover with cable glands\nMake: Valrack/Emerson/HiveNetwork/GADAN | 18 | Nos | |
| 619 | 7.18 | CCTV - NON SCHEDULED ITEMS | |||
| 620 | 7.19 | Supply Installation Testing & Commissioning of 4MP IP Network bullet camera including cost of petty material required to complete the work upto the entire satisfaction of engineer in charge having following techincal specifications | 130 | Each | |
| 621 | 7.2 | Image Sensor : 1/3\" 4 megapixel progressinve scan CMOS sonsor or better. | |||
| 622 | 7.21 | Effective pixels : 2688(H)x 1520(V)or better | |||
| 623 | 7.22 | Electronic shutter : Auto/manual 1/3(4) 1/100000s | |||
| 624 | 7.23 | scannng system: Progressive | |||
| 625 | 7.24 | S/N Ratio More than 50dB | |||
| 626 | 7.25 | Min IR LED Length>70m | |||
| 627 | 7.26 | IR Leds : 2 or better | |||
| 628 | 7.27 | Day/Night : Auto(ICR)/Color/B/W | |||
| 629 | 7.28 | Back light compensation : BLC/HLC/WDR(120DB) | |||
| 630 | 7.29 | White balance : auto/natural/street lamp/out door/manual | |||
| 631 | 7.3 | Motion detection : Off/On(4Zone, rectangle) | |||
| 632 | 7.31 | Focal Lenght :3.6mm | |||
| 633 | 7.32 | Region of Interest :Off/On(4Zone) | |||
| 634 | 7.33 | Video compression :H.265+/H.265 | |||
| 635 | 7.34 | Resolution : 4mp | |||
| 636 | 7.35 | streaming capability : 3 | |||
| 637 | 7.36 | digital zoom : 16x | |||
| 638 | 7.37 | Bit rate: H.265 :14 9984 kbps | |||
| 639 | 7.38 | Network ethernet :RJ 45 (10/100Base-T) | |||
| 640 | 7.39 | Protocol: HTTPs. : TCP :ARP: RTSP : RTP : UDP :SMPT :FTP : DHCP :DNS : DDNS :PPPOL : IPv4 v6 : Qos : UPnP:NTP: Bonhour 802.1xMulticast : ICMP IGMP:SNMP | |||
| 641 | 7.4 | compatibility :ONVIF | |||
| 642 | 7.41 | SD Card :Min 128GB SD Card support | |||
| 643 | 7.42 | Working environment :-30 c to +60c less than 95% RH (no condensation) | |||
| 644 | 7.43 | Ingress protecton: IP67 | |||
| 645 | 7.44 | Vindal resistance : IK10 | |||
| 646 | 7.45 | Audio interface : 1/1 channel in/out | |||
| 647 | 7.46 | Alarm : 1 channel In : 5MA 5 VDC, 1 channel out 300 mA 12VDC | |||
| 648 | 7.47 | Inelligence (IVS): Triwire, Instrusion object abandoned/Missing. | |||
| 649 | 7.48 | Advanced intelligent functions : Face Detecion | |||
| 650 | 7.49 | Certification : CE ,FCC,UL | |||
| 651 | 7.5 | Make : DAHUA/HYUNDAI/PELCO/HONEYWELL | |||
| 652 | 7.51 | Supply Installation testing & commissning of Video Management Recorder including cost of petty material required to complete the work up to the entire satisfaction of Engineer In charge having following technical specifications: Main Processor: Quad-Core Embedded processor of better Processor or better Operating System: Embedded LINUX IP Camera Input:-32 Channel or More Two-Way Talk: 1 Channel input 1 Channel output/RCA Interface:>/ 1 HDML,>/1VGA Compression : H.265/H.264 | 2 | Each | |
| 653 | 7.52 | Resolution:-8MP, 6MP,5MP,4MP,3MP, 1080P,1.3MP,720P etc. | |||
| 654 | 7.53 | Record rate :-200Mbps | |||
| 655 | 7.54 | Record Mode: Manual, Schedule (Regular,MD (Motion Detction ), Alarm, Analytics), Holiday Stop. | |||
| 656 | 7.55 | Video Detection: Motion Detection Video Loss and Tampering Multiple VCA Events Alarm input : >/ Channel | |||
| 657 | 7.56 | Relay out put:>/ 2 Channel | |||
| 658 | 7.57 | Search Mode: Time/Date, Alarm, MD/ Smart Search | |||
| 659 | 7.58 | Back Mode : USB Device/Network/EASTA Device | |||
| 660 | 7.59 | Network Interface: 4RJ-45 Ports (10/100/1000Mbps) | |||
| 661 | 7.6 | Ethernet port:- 1 Independent 1000Mbps Ethernet Ports | |||
| 662 | 7.61 | Network Function: HTTP,HTTPs.TCP/IP,IPv4/IPv6,UPnP,RTSP, UDP,SMTP,NTP,DHCP,DNS,IP Filter, PPPoE,DDNS,FTP,Alarm Server,IP Search etc. | |||
| 663 | 7.62 | User Access:>/ 128 users | |||
| 664 | 7.63 | Smart Phone: iPhone, Ipand, Android | |||
| 665 | 7.64 | Interoperability: ONVIF 2.4, CGI Conformant | |||
| 666 | 7.65 | Internal HDD: Internal min 2 SATA HDD port, upt 6TB HDD support per Slot | |||
| 667 | 7.66 | USB Ports | |||
| 668 | 7.67 | Operating Conditions:-10' C ~ +55` C | |||
| 669 | 7.68 | Certifications: CE, UL, FCC | |||
| 670 | 7.69 | Make:DAHUA/HYUNDAI/HONEYWELL/ PELCO | |||
| 671 | 7.7 | Supply Installation testing & commissning of Outdor 4*4 Box Including cost of petty material required to complete the work upto the entire satisfaction of Engineer In charge having Make :-STRONGER/MOLEX/AMP Item required for out side camera connector protection | 130 | Each | |
| 672 | 7.71 | Supply, Installation, Testing and comissioning of 8 port Layer -2 managable supply instalation Testing and comissioning of 8 port Layer -2 managable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe port for copper fiber uplink 20gbps switching capacity 14.88mbps forwarding performance maximum power consumption minimum 85 watt Make:Cisco/Ericsson/Juniper | 20 | Each | |
| 673 | 7.72 | Supply Installation Testing & Commissioning of 6TB servilance hard disk including cost of petty material required to complete the work up to the entire satisfaction of Engineer In Charge Make: WD-PURPLE/SEGATE. | 20 | Each | |
| 674 | 7.73 | Supply Installation Testing & Commissioning of 12U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work.\nMakes: Valrack /Comrack / HCL | 2 | Each | |
| 675 | 7.74 | Supply Installation Testing & Commissioning of 32\" LED Monitor, HDMIPort. Resolution:-1920 x 1080 (FHD) , Back light TYPE- LED (edge), Viewing Angle degree - 178x178, Life span (hrs) 30,000, Brightness (cd/m2)- 200, or better,\nMake: Sony/Panasonic/Samsung | 2 | Each | |
| 676 | 7.75 | Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. \nMake: Finolex/Polycab/Havells | 2000 | Meter | |
| 677 | 7.76 | Supply Installation Testing & Commissioning of CAT 6 UTP Cable.\nMake: PANDUIT/R&N/SYSTIMAX | 8000 | Meter | |
| 678 | 7.77 | Supply and erection of PVC pipe25mm dia ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work.\nMake: BEC, AKG, Kalinga / Diplast | 8000 | Meter | |
| 679 | 7.78 | Supply Installation Testing & Commissioning of 1 KVA UPS with 1 hr back up: 1KVA ONLINE UPS TRUE ONLINE - DOUBLE CONVERSION, IGBT BASED MAKE: EMERSON LIEBERT MODEL: GXT MT LB WITH 1 PHASE IN / 1 PHASE OUT WITH ACTIVE INPUT POWER FACTOR CORRECTION 0.99 INPUT VOLTAGE (110 - 280V AC) INPUT FREQUENCY 40Hz - 70Hz OUTPUT 200/208/220/230/ 240V AC - 1% THDv <3% ON LINEAR LOAD AND <6% ON NON LINEAR LOAD WITH OVCD AND LCD DISPLAY, SMF BATTERIES BANK \nOF 42AH/12VOLT*3NOS with RACK AND INTERCONNECTORS.\nMAKE APC/ LIBERT/ Emerson | 8 | Each |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy