}

Purchase Of Electrical Maintenance Work, BIET JHANSI-Uttar Pradesh

Bundelkhand Institute of Engineering and Technology has published Purchase Of Electrical Maintenance Work. Submission Date for this Tender is 24-02-2020. Electrical Products Tenders in BIET JHANSI Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

23498015
Purchase Of Electrical Maintenance Work
Open Tender
Indian
Uttar Pradesh
Biet Jhansi
24-02-2020

Tender Details

Purchase Of Electrical Maintenance Work-1 Supply And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Sides And Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. N ( A ) 25 Sq. Mm 3-1 / 2 Core. Ps No. 501 ( J ) N 2 Supply And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Sides And Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. N ( B ) 35 Sq. Mm 3-1 / 2 Core. Ps No. 501 ( K ) 3 Supply And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Sides And Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. N ( C ) 50 Sq. Mm 3-1 / 2 Core. Ps No. 501 ( L ) 4 Supply And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Sides And Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. N ( D ) 95 Sq. Mm 3-1 / 2 Core. Ps No. 501 ( N ) 5 Supply And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Sides And Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. N ( E ) 400 Sq. Mm 3-1 / 2 Core. Ps No. 501 ( T ) 6 Supply And Fixing Of Brass Nickel Plated Compression Gland For Pvc Insulted & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Direction Of Engineer-Incharge. N ( A ) 25 Sq. Mm 3-1 / 2 Core. Ps No. 503 ( J ) N 7 Supply And Fixing Of Brass Nickel Plated Compression Gland For Pvc Insulted & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Direction Of Engineer-Incharge. N ( B ) 35 Sq. Mm 3-1 / 2 Core. Ps No. 503 ( K ) N 8 Supply And Fixing Of Brass Nickel Plated Compression Gland For Pvc Insulted & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Direction Of Engineer-Incharge. N ( C ) 50 Sq. Mm 3-1 / 2 Core. Ps No. 503 ( L ) N 9 Supply And Fixing Of Brass Nickel Plated Compression Gland For Pvc Insulted & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Direction Of Engineer-Incharge. N ( D ) 95 Sq. Mm 3-1 / 2 Core. Ps No. 503 ( N ) N 10 Supply And Fixing Of Brass Nickel Plated Compression Gland For Pvc Insulted & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Direction Of Engineer-Incharge. N ( E ) 35 Sq. Mm 3-1 / 2 Core. Ps No. 503 ( T ) 11 Supply & Fixing Of Plain Or Pin Type Copper Tin Plated Cable Socket ( Lug ) To The Cable Leads, Insulating With Tape And Making Connection Etc. Complete In All Respect As Per Direction Of The Engineer-Incharge. N ( A ) 25 Sq. Mm. Ps No. 504 ( E ) N 12 Supply & Fixing Of Plain Or Pin Type Copper Tin Plated Cable Socket ( Lug ) To The Cable Leads, Insulating With Tape And Making Connection Etc. Complete In All Respect As Per Direction Of The Engineer-Incharge. N ( B ) 35 Sq. Mm. Ps No. 504 ( F ) 13 Supply & Fixing Of Plain Or Pin Type Copper Tin Plated Cable Socket ( Lug ) To The Cable Leads, Insulating With Tape And Making Connection Etc. Complete In All Respect As Per Direction Of The Engineer-Incharge. N ( C ) 50 Sq. Mm. Ps No. 504 ( G ) N 14 Supply & Fixing Of Plain Or Pin Type Copper Tin Plated Cable Socket ( Lug ) To The Cable Leads, Insulating With Tape And Making Connection Etc. Complete In All Respect As Per Direction Of The Engineer-Incharge. N ( E ) 95 Sq. Mm 3-1 / 2 Core. Ps No. 504 ( I ) 15 Supply & Fixing Of Plain Or Pin Type Copper Tin Plated Cable Socket ( Lug ) To The Cable Leads, Insulating With Tape And Making Connection Etc. Complete In All Respect As Per Direction Of The Engineer-Incharge. N ( E ) 400 Sq. Mm. Ps No. 504 ( 0 ) N 16 Supply & Wiring Of Submain Fr Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia. Heavy Duty ( 2Mm Thick ) Pvc Conduct With One Number Fr Pvc Insulted 1100 V Grade Multistrand Copper Conductor Cable As Earth Continuity Wire Drawn Insid The Conduct. N ( A ) Submain With Two Number 1.5 Mm² Copper Cable & 1.5 Mm² Cpper Cable As Earth Ps No. 1311 ( C ) 17 Supply & Wiring Of Submain Fr Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia. Heavy Duty ( 2Mm Thick ) Pvc Conduct With One Number Fr Pvc Insulted 1100 V Grade Multistrand Copper Conductor Cable As Earth Continuity Wire Drawn Insid The Conduct. N ( B ) Submain With Two Number 2.5 Mm² Copper Cable & 1.5 Mm² Cpper Cable As Earth Ps No. 1301 ( C ) 18 Supply & Wiring Of Submain Fr Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia. Heavy Duty ( 2Mm Thick ) Pvc Conduct With One Number Fr Pvc Insulted 1100 V Grade Multistrand Copper Conductor Cable As Earth Continuity Wire Drawn Insid The Conduct. N ( C ) Submain With Two Number 4.0 Mm² Copper Cable & 2.5 Mm² Cpper Cable As Earth Ps No. 211 ( C ) 19 Supply & Wiring Of Submain Fr Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia. Heavy Duty ( 2Mm Thick ) Pvc Conduct With One Number Fr Pvc Insulted 1100 V Grade Multistrand Copper Conductor Cable As Earth Continuity Wire Drawn Insid The Conduct. N ( D ) Submain With Two Number 6.0 Mm² Copper Cable & 4.0 Mm² Cpper Cable As Earth Ps No. 212 ( C ) 20 Supply & Wiring Of Submain Fr Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia. Heavy Duty ( 2Mm Thick ) Pvc Conduct With One Number Fr Pvc Insulted 1100 V Grade Multistrand Copper Conductor Cable As Earth Continuity Wire Drawn Insid The Conduct. N ( E ) Submain With Two Number 10 Mm² Copper Cable & 6.0 Mm² Cpper Cable As Earth Ps No. 213 ( C ) 21 Supply & Burring Of Safe Earthing Electrode T-39, ( Hot Dip Galvanized ) , Length Up To 3000Mm, Outer Dia 76Mm Inner Dia 38Mm, Terminal Dia 12Mm, Outer Gi Pipe Of 16 Swg And Inner Gi Pipe Of 12 Swg With Hot Dip Galvanized Up To 100 Micron Filled With Crystalline Conductive Mixture ( Ccm ) Having Anti Corrosive & Conductive Property With 50 Kgs Activated Soil ( Bfc ) Capable Of Reducing The Soil Resistivity With Good Mixture Of Retaining Capacity And One Earthing Lead Of 20 X 3 G.I. Strip, Upto Switch Board Along With 30Cm Square C.I. Frame With Hinged Cover & Masonry Housing. Ps No. 725 ( B ) 22 S&F Surface / Flush Mounting Spn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. N ( A ) 4 Way Ps No. 1022 ( A ) Cat-B 23 S&F Surface / Flush Mounting Spn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. N ( B ) 8 Way Ps No. 1024 ( A ) Cat-B 24 S&F Surface / Flush Mounting Spn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. N ( C ) 12 Way Ps No. 1025 ( A ) Cat-B 25 Supply & Fixing Of Mcb Sp 240 / 415 V ( 10 Ka ) Ps No. 1002 ( A ) Havells / Ssk / Indocop Cat-B As Given N ( A ) 6 Amp Ps No. 1002 ( A ) 26 Supply & Fixing Of Mcb Sp 240 / 415 V ( 10 Ka ) Ps No. 1002 ( A ) Havells / Ssk / Indocop Cat-B As Given N ( B ) 10 Amp Ps No. 1002 ( A ) 27 Supply & Fixing Of Mcb Sp 240 / 415 V ( 10 Ka ) Ps No. 1002 ( A ) Havells / Ssk / Indocop Cat-B As Given N ( C ) 16 Amp Ps No. 1002 ( A ) 28 Supply & Fixing Of Mcb Sp 240 / 415 V ( 10 Ka ) Ps No. 1002 ( A ) Havells / Ssk / Indocop Cat-B As Given N ( D ) 20 Amp Ps No. 1002 ( A ) 29 Supply & Fixing Of Mcb Sp 240 / 415 V ( 10 Ka ) Ps No. 1002 ( A ) Havells / Ssk / Indocop Cat-B As Given N ( E ) 25 Amp Ps No. 1002 ( A ) 30 ( A ) Supply & Fixing Of Isolater 40 Amp Dp 240 / 415 V ( 10 Ka ) Ps No. 1005 ( A ) Havells / Ssk / Indocop Cat-B 31 ( B ) Supply & Fixing Of Isolate 63 Amp Dp 240 / 415 V ( 10 Ka ) Ps No. 1005 ( B ) Havells / Ssk / Indocop Cat-B 32 S&F Of 32 Amp 240 V Dp Metal Clad Rewireable Type Switch Fuse Unit On M.D.F.E.G / Teak Wood Board Complete In All Respect. Ps No. 305 Havells / Ssk / Indocop Cat-B 33 S&F Of 63 Amp 415 V Heavy Duty Double Break Hrc Fuse Type Metal Clad Tpn Complete With Hrc Fuse Etc. Complete In All Respect. Ps No. 345 Havells / Ssk / Indocop Cat-A 34 S&F Of 100 Amp 415 V Heavy Duty Double Break Hrc Fuse Type Metal Clad Tpn Complete With Hrc Fuse Etc. Complete In All Respect. Ps No. 346 Havells / Ssk / Indocop Cat-A 35 Supply & Fixing Of Recess / Surface / Pendent Mounting Round 12-15 Watt Led Down Lighter Having Coated Die Cast Aluminnium Housing With Heat Shrink, Diffuser / Reflector & Driver Set Complete In All Respect. Ps. No. 1401 36 Supply & Fixing Of Cable Root Marker In Suitable Masonary Enclosure As Directed By Engineer Incharge. Ps. No. 505 37 Supply & Erracetion Of Incoming 630 Amp. Mccb-1 No. & Outgoing 100 Amp. Mccb-5 Nos. & 63 Amp. Mccb-2 Nos. Factory Fabricated & Wired Metal Clad Dust And Vermin Proof Floor Mounting, M.S. Channel Base With Bottom And Top Cable Entries Electrical Control Panel With Tpn Mccbs ( Four Pole 36 Ka With Thermal Magnatic Release ) Switches Complete And Instrument Chamber Etc. Complete In All Respects. The Instrument Chamber Shall Be Separate And Shall Compromise Of Flush Type Digital Metering System For Phase To Phase Voltage And Single Phase Voltage, Current And Other Parameters ( Kva, P.F, Kw Etc ) In Each Phase With Touch Type Selector Switches For Different Readings, Instrument Fuses, Current Transformer Etc. The Panel Board Shal Have Suitable Capacity Electrolytic Aluminium Busbars As Per Is8623 Or Above Insulated With Heat Shrink Sleeving And Mounted On Non Hygroscopic Supports Such As Cmc / Bmc Support With Deteachable Sice Covers And Shall Be Suitable For Extension On The Sides. The Mccbs Shall Be Complete With Suitable Cable End Boxes, Compression Glands And Indicating Lamp On Incoming Etc. Nthe Job Includes The Grounting Of The Board As Per Directions Of Engineer-Incharge. All Out Goings Of 100 Amp And Above Shall Have An Ammeter. The Panel Board Shall Be Fabricated With Crca Sheet With A Minimum Thickness Of 1.6Mm / 2Mm. Cat. A Panel Cubicle Type Switch Board Shall Be Of Cat B Only. Ps No. 814 ( A ) 38 Supply & Wiring Of Submains With Two Nos. Of 2.5 Sq. Mm Fr Pvc Insulated 1100 V Grade Single Core Multistrand Copper Conductor Cable In Existing Conduit Complete With Supply Of All Material, Labour & T&P Etc. Required For Proper Completion Of The Work As Directed At Site By The Engineer Incharge. Ps No.289 39 Supply & Wiring Of Submains With Two Nos. Of 4 Sq. Mm Fr Pvc Insulated 1100 V Grade Single Core Multistrand Copper Conductor Cable In Existing Conduit Complete With Supply Of All Material, Labour & T&P Etc. Required For Proper Completion Of The Work As Directed At Site By The Engineer Incharge. Ps No.289 ( A ) 40 Wiring Point For Light With 1.5 Sq Mm Fr Pvc Insulated Multistrand Single Core Copper Conductor Cable ( Drawn Through Existing Concealed Steel Conduit ) And 5 Amp. Flush Type Switch & Ceiling Rose / Angle / Batten Holder Fixed With 3Mm Thick Phenolic Laminated Backalite Sheet With Brass Machine Screw And Cup Washers Mounted Over Existing Ms Switch Board Box / Junction Box With Supply Of All Material, Labour & T&P Etc. Required For Proper Completion Of The Work As Directed At Site By The Engineer In Chage. Ps No. 174 ( B ) 41 Wiring Point For Fant With 1.5 Sq Mm Fr Pvc Insulated Multistrand Single Core Copper Conductor Cable ( Drawn Through Existing Concealed Steel Conduit ) And 5 Amp. Flush Type Switch & Fixed With 3Mm Thick Phenolic Laminated Backalite Sheet With Brass Machine Screw And Cup Washers Mounted Over Existing Ms Switch Board Box / Junction Box With Supply Of All Material, Labour & T&P Etc. Required For Proper Completion Of The Work As Directed At Site By The Engineer In Chage. Ps No. 177 ( B ) 42 Wiring Point For Plug Point With 1.5 Sq Mm Fr Pvc Insulated Multistrand Single Core Copper Conductor Cable ( Drawn Through Existing Concealed Steel Conduit ) And 5 Amp. Flush Type Switch & 3 Pin Socket And Earth Continuity Wire Of 1.5 Sq Mm Pvc Insulated Muktistrand Copper Conductor Cable. Fixed With 3Mm Thick Phenolic Laminated Backalite Sheet With Brass Machine Screw And Cup Washers Mounted Over Existing Ms Switch Board Box / Junction Box With Supply Of All Material, Labour & T&P Etc. Required For Proper Completion Of The Work As Directed At Site By The Engineer In Chage. Ps No. 178 ( B ) 43 Electrical Fire Extinguisher Nsupply Of Abc Type Fire Extinguisher 06 Kg With ( Isi ) Mark 44 Electrical Fire Extinguisher Nsupply Of Abc Type Fire Extinguisher 09 Kg With ( Isi ) Mark 45 Electrical Fire Extinguisher Nabc Type Fire Extinguisher 05 Kg Filling 46 Electrical Fire Extinguisher Nabc Type Fire Extinguisher 10 Kg Filling 47 Dcp Type Fire Extinguisher 05 Kg Filling 48 Electrical Fire Extinguisher Ndcp Type Fire Extinguisher 10 Kg Filling 49 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( A ) Incoming 800 Amp Tp Acb Cat-A 50 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( B ) Coupler 800 Amp Tp Acb Cat-A 51 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( C ) Outgoing 630 Amp Tpn Switch Disconnector Fuse Unit Cat-A 52 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( D ) Outgoing 250 Amp Tpn Switch Disconnector Fuse Unit Cat-A 53 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( E ) Outgoing Replacement 100 Amp Tpn Mccb Cat-A 54 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( F ) Outgoing 63 Amp Tpn Mccb Cat-A 55 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( G ) Outgoing 32 Amp Tpn Mccb Cat-A 56 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( H ) Busbar 800 Amp Cat-A 57 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( I ) Busbar 250 Amp Cat-A 58 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( J ) 4 Pole Change Over 800 Amp Cat-A 59 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( K ) Replacement Of Ct 60 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( L ) Replacement Of Ammeter 61 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( M ) Replacement Of Voltmeter 62 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( N ) Replacement Of Indicator Lamp 63 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( O ) Wiring Copper Wire 64 Repairing, Maintenance, Overhaulling Service, Testing & Energizing Of L&T Make Tp Acb Panel As Given N ( P ) Hrc Fuse 250 Amp Replacement 65 Repairing Maintenance, Overhaulling Service, Testing & Energizing Of 500 Kva Transformer N ( A ) Transportation Loading, Unloading & Testing Of 500 Kva 11 / .4 Kv Transformer 66 Repairing Maintenance, Overhaulling Service, Testing & Energizing Of 500 Kva Transformer N ( B ) Repairing & Rewinding Of 500 Kva 11 / 0.43Kv Transformer ( With Replacement Of Tap Changer, Lt Bush Road, Ht Bush Road & Labour Charges ) 67 Repairing Maintenance, Overhaulling Service, Testing & Energizing Of 500 Kva Transformer N ( C ) Supply Of New Transformer Oil 68 Repairing Maintenance, Overhaulling Service, Testing & Energizing Of 500 Kva Transformer N ( D ) Spray Painting 69 Supply, Replacement & Erracetion Of 200 Amp ( Four Pole 36 Ka With Thermal Magnetic Release ) Mccb L&T Cat -A 70 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( A ) Wet Service 71 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( B ) Running Capacitor 72 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( C ) Starting Capacitor 73 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( D ) Gas Refil 74 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( E ) Fan Motor Rewinding 75 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( F ) Gas Pipe Welding 76 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( G ) Duct 77 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( H ) Filter Grill 78 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( I ) Compressor Window Ac 79 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( J ) Compressor Split Ac 80 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( K ) Relay 81 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( L ) Connector 82 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( M ) Wiring Kit 83 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( N ) Thermostat 84 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( O ) Chill Tray 85 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( P ) Service Charge Split 86 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( Q ) Pcb Display 87 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( R ) Drain Pipe 88 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( S ) Stabilizer Repairing Transformer 89 Electrical Maintenance Work ( Non Schedule Work ) Nac Repairing N ( T ) Stabilizer Repairing Pcb 90 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( A ) Water Tank Repair 120 L 91 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( B ) Water Tank Repair 150 L 92 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( C ) Float Valve 93 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( D ) Filter + Capillary 94 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( E ) Gas Filling Charge 95 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( F ) Compressor 775 W 96 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( G ) Compressor 1550 W 97 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( H ) Body Repair 98 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( I ) Making New Base 99 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( J ) Relay 100 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( K ) Starting Capacitor 101 Electrical Maintenance Work ( Non Schedule Work ) Water Cooler Repairing N ( L ) Running Capacitor 102 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( M ) Fan Motor Rewinding & Repairing 103 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( N ) Loading & Unloading 104 Electrical Maintenance Work ( Non Schedule Work ) Nwater Cooler Repairing N ( O ) Service Charge 105 Electrical Maintenance Work ( Non Schedule Work ) Nsubmersible Pump Repairing N ( A ) 1 Hp Single Phase Motor Rewinding & Pump Repairing 106 Electrical Maintenance Work ( Non Schedule Work ) Nsubmersible Pump Repairing N ( B ) 2 Hp Single Phase Motor Rewinding & Pump Repairing 107 Electrical Maintenance Work ( Non Schedule Work ) Nsubmersible Pump Repairing N ( C ) 3 Hp Single Phase Motor Rewinding & Pump Repairing 108 Electrical Maintenance Work ( Non Schedule Work ) Nsubmersible Pump Repairing N ( D ) 1 Hp Starter Repairing 109 Electrical Maintenance Work ( Non Schedule Work ) Nsubmersible Pump Repairing N ( E ) 2 Hp Starter Repairing 110 Electrical Maintenance Work ( Non Schedule Work ) Nsubmersible Pump Repairing N ( F ) 3 Hp Starter Repairing 111 Electrical Maintenance Work ( Non Schedule Work ) Nfan Repairing N ( A ) Fan Copper Rewinding & Repairing 900 Mm 112 Electrical Maintenance Work ( Non Schedule Work ) Nfan Repairing N ( B ) Fan Copper Rewinding & Repairing1200 Mm 113 Electrical Maintenance Work ( Non Schedule Work ) Nfan Repairing N ( C ) Fan Copper Rewinding & Repairing 1400 Mm 114 Electrical Maintenance Work ( Non Schedule Work ) Nfan Repairing N ( D ) Air Fresher Copper Rewinding & Repairing 115 Electrical Maintenance Work ( Non Schedule Work ) Nfan Repairing N ( E ) Air Fresher Copper Rewinding & Repairing 116 Electrical Maintenance Work ( Non Schedule Work ) Nfan Repairing N ( F ) Exhaust Fan Copper Rewinding & Repairing 117 Electrical Maintenance Work ( Non Schedule Work ) Nfan Repairing N ( G ) Replacement Of Bearing Set 118 Electrical Maintenance Work ( Non Schedule Work ) Nfan Repairing N ( H ) Pairing

Key Value

Document Fees
INR 1180 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail