| 1 | 1 | Stripping off worn out plaster and raking joints of walls, ceilings etc. upto any height and in any floor including removing rubbish as directed within a lead of 75m. | | 53.49 | Sq.m. |
|---|
| 2 | 2 | Dismantling artificial stone flooring upto 50mm thk by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75m. | | 101.93 | Sq.m. |
|---|
| 3 | 3 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good damages complete. | | 2.1 | Sq.m. |
|---|
| 4 | 4 | Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any, in Ground Floor as per revelent IS codes .\nRiver Bazree upto 4th Floor | | 0.34 | Cu.m |
|---|
| 5 | 5 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length hooking and bending to correct shape placing in proper position and binding with16G black annealed wire at every intersection as per drawing and direction. \n(a) For works in foundation and upto roof of top floor/upto 4 m | | 0.03 | MT |
|---|
| 6 | 6 | Hire and labour charges for shuttering with centering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs,beams,columns,lintels curved or straight including fitting , fixing and striking out after completion of works(upto roof of ground ground floor) \n25mm to 30mm thick wooden shuttering as per decision & direction of Engineer-In-Charge | | 3.36 | Sq.m. |
|---|
| 7 | 7 | 125 mm thick brick work with 1st class bricks in cement mortar (4:1) in ground floor | | 4.32 | Sq.m. |
|---|
| 8 | 8 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\n(ii) With 1:4 cement mortar (b) 15 mm thick plaster | | 24.44 | Sq.m. |
|---|
| 9 | 9 | Supplying, fitting and fixing granite slabs 15mm to 18mm thickness with uniform texture & without decorative veins in columns, wall, facia etc. with 15mm thick (avg) cement morter (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement morter (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of Engineer-In-Charge including cost of materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. (Using cement slurry at back side of granite @ 4.4kg/m2 & white cement slurry for joint filling @ 1.8kg/m2) | | 3.92 | Sq.m. |
|---|
| 10 | 10 | Supplying and laying true to line and level vitrified tiles of approved brand(size not less than 600mmx600mmx10mm thk) in floor, skirting etc. set in 20mm sand cement mortar(1:4) and 2mm thk cement slurry back side of tiles using cement @ 2.91kg/m2 or using polymerised adhesive(6mm thk layer applied directly over finished artificial stone floor/mosiac etc without any backing course) laid after application slurry using 1.75kg of cement per m2 below mortar only, joints grouted with admixture of white cemet and colouring pigment to match with colour of tiles/epoxy groutmaterials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete true to materials, labour and all other incidential charges complete true to manufacturer's specification and direction of Engineer-In-Charge.(White cement, synthetic adhesive and grout materials to be supplied by the contractor) | | 101.93 | Sq.m. |
|---|
| 11 | 11 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. b) Wall First Floor | | 68.28 | Sq.m. |
|---|
| 12 | 12 | Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand (1.5mm thk) | | 631.7 | Sq.m. |
|---|
| 13 | 13 | Priming one coat to timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surface by sand papering | | 631.7 | Sq.m. |
|---|
| 14 | 14 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on surface if necessary. \non timber or plastered surface: with super gloss (hi-gloss)\nTwo coats (with any shade except white) | | 631.7 | Sq.m. |
|---|
| 15 | 15 | Supplying profiles of reqrd. Section made of Aluminium Alloy extrussion conforming to IS:733-1983 and IS: 1285-1977. Annodised (with required film thickness and specified colour/natural) matt finished conforming to IS 1968-1983 for fabrication of composite door, sliding & casement windows partitions , formend of basic sections of any ISI embossed/certified make and brand as per direction of Engineer-in-Charge. \n(B) in 15 micron colour annodising \na) Fixed Partition ( Unsupported length of vertical members more than 1.5mtr or both ends of vertical members restrained but panels more than 0.90Sq.m\n | | 16 | Mtr. |
|---|
| 16 | 16 | (ii) Intermidiate member p no 238 . B.j. ii | | 17.35 | Mtr. |
|---|
| 17 | 17 | (iii) glazing clip - p no 238 . B.j. iii | | 66.7 | Mtr. |
|---|
| 18 | 18 | Fixed Partition ( Unsupported length of vertical members more than 1.5mtr or both ends of vertical members restrained but panels more than 0.90Sq.m | | 6 | Mtr. |
|---|
| 19 | 19 | Bottom rail. p no 239 . B.k. ii | | 1.2 | Mtr. |
|---|
| 20 | 20 | Lock Rail | | 2.4 | Mtr. |
|---|
| 21 | 21 | Door Vertical | | 4.8 | Mtr. |
|---|
| 22 | 22 | Glazing clip | | 28.8 | Mtr. |
|---|
| 23 | 23 | Labour charge for fabricating and installation of composite door window, partitin made from annodised extruded alloy sections for the following units:-\n(D) Partly glazed and partly panelled partition or fixed glazing made of extruded and anodised alloy aluminium sections, fabrications after cutting to proper shape and size, drilling and aligning fitted with inbuilt locking arrangement cutting the glass / board (prelaminated / particle / block) to requisite shape and size moulding the edges fitted and fixed glazing clips and dry set neoprine /EPDM gasket, along with all other necessary arrangements for fixing the partition to walls, floors, beams, columns polysulphide sealant for water proofing if necessary complete in all respect as per drawing and specifications and direction of the Engineer in charge.\nI) For partitions using section of size: | | 15 | Sq.m. |
|---|
| 24 | 24 | C) Fully glazed single leaf reamless swing door made of anodized aluminium alloy extrusions fabrication after cutting to proper shape and size, drilling and aligning fitted with heavy duty hydraulic action floor spring with top pin assembly and fitted with inbuilt locking arrangement and all other necessary fittings, fixture, adhesives and joineries, cutting the glass to requisite shape and size mounting the edges for fitting the same with dry set neoprine/EPDM gasket. | | 2.88 | Mtr. |
|---|
| 25 | 25 | Supplying 4 lever mortice lock of any approved make and brand as per direction of Engineer-in-charge. 150mm | | 1 | Nos. |
|---|
| 26 | 26 | Supplying 125mm dia acrlylic handle for aluminium door as per approved make and brand. (a) Natural colour. | | 2 | Nos |
|---|
| 27 | 27 | Supplying bubble free float glass of approved make and brand. Confirming to IS 2835-1987\n8mm thick clear glass | | 17.88 | Sq.m. |
|---|
| 28 | 28 | Wall panelling / partition with Melamine faced 3 layered flat pressed wood particle board of approved make and brand as per direction of Engineer - in Charge of requisite grade bonded with phenol formaldehyde synthetic resin conforming to IS: 848 - 1974 (excluding the cost of supporting frame work and teak wood battens / lipping)\nIn Ground Floor | | 25.08 | Sq.m. |
|---|