Provision Of Klp Accn For No Iii Bn Of Hq 41 Inf Bde At Lucknow

Tender Notice

23469197
Provision Of Klp Accn For No Iii Bn Of Hq 41 Inf Bde At Lucknow
Indian
Uttar Pradesh
26-03-2020
04-05-2020
08-05-2020

Tender Details

Provision Of Klp Accn For No Iii Bn Of Hq 41 Inf Bde At Lucknow

Corrigendum Details

Sr No CorrigendumDate Description Submission Date
1 04-03-2020 Postpone 03-04-2020
2 26-03-2020 Postpone and revised dates 04-05-2020

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.00 /-
Tender Value
INR 50 Crore /-

Attachment

FileName File Description File Size
Tender41.pdf Tender Document-TENDER DOCUMENT 2585.63
ECFD7656-216F-42CC-88BB-C4330FE72F82.html Tender Notice-Tender Notice 0
BOQ_358857.xls Tender Document-BOQ 10734.50
41Drgs.rar Tender Document-DRAWINGS 26913.39
Tendernotice_1.pdf Tender Document-NIT 369.53

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work: PROVISION OF KLP ACCN FOR 01xINF BN OF 41 MTR BDE AT LUCKNOW
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Sch 'A' Part-I (Building Work)\nNote : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
2 1.01 Construction of block of Office and Admin Accn with computer room complete all as shown on drawings and specified.\n 1 Each Block
3 1.02 Construction of block of Car Parking at office ACCN for 05 cars complete all as shown on drawings and specified.\n 4 Each Block
4 1.03 Construction of block of Parking for scooters (50 Nos) . for ADM bldg complete all as shown on drawings and specified.\n 1 Each Block
5 1.04 Construction of block of Single living accn for 10 nos. HAV & 72 nos. ORs (T/S) (Block-A) complete all as shown on drawings and specified.\n 1 Each Block
6 1.05 Construction of block of Single living accn for 12 nos. HAV & 64 nos. ORs (T/S) (Block-B) complete all as shown on drawings and specified.\n 4 Each Block
7 1.06 Construction of block of Single living accn for 10 nos. HAV & 65 nos. ORs (T/S) (Block-C) complete all as shown on drawings and specified.\n 1 Each Block
8 1.07 Construction of block of JCO's Mess (club) for 42 Jco's (41-60) complete all as shown on drawings and specified.\n 1 Each Block
9 1.08 Construction of block of Cook house and Dining hall complete all as shown on drawings and specified.\n 6 Each Block
10 1.09 Construction of block of Single living Accn for 03 officers complete all as shown on drawings and specified.\n 1 Each Block
11 1.1 Construction of block of Officers mess (11-18) complete all as shown on drawings and specified.\n 1 Each Block
12 1.11 Construction of block of Servant Quarters for officers mess (D/S) ( 09 nos) complete all as shown on drawings and specified.\n 1 Each Block
13 1.12 Construction of block of Open garage with apron for 04 cars complete all as shown on drawings and specified.\n 1 Each Block
14 1.13 Construction of block of Storage Accn complete all as shown on drawings and specified.\n 1 Each Block
15 1.14 Construction of block of Gas store complete all as shown on drawings and specified.\n 1 Each Block
16 1.15 Construction of block of Specialist Storage Accn complete all as shown on drawings and specified.\n 1 Each Block
17 1.16 Construction of block of Training shed complete all as shown on drawings and specified.\n 1 Each Block
18 1.17 Construction of block of Tradesman Shop complete all as shown on drawings and specified.\n 1 Each Block
19 1.18 Construction of block of Unit shops complete all as shown on drawings and specified.\n 1 Each Block
20 1.19 Construction of block of Drying & Ironing room complete all as shown on drawings and specified.\n 1 Each Block
21 1.2 Construction of block of Education building complete all as shown on drawings and specified.\n 1 Each Block
22 1.21 Construction of block of Family Wellfare Centre complete all as shown on drawings and specified.\n 1 Each Block
23 1.22 Construction of block of Religious Institute hall complete all as shown on drawings and specified.\n 1 Each Block
24 1.23 Construction of block of Battery charging room complete all as shown on drawings and specified.\n 1 Each Block
25 1.24 Construction of block of Guard room and ancillaries , armouries , SAA store and ARMOURER SHOP complete all as shown on drawings and specified.\n 1 Each Block
26 1.25 Construction of block of Covered ACCN for truck 2.5 ton (Block of 07 Veh) complete all as shown on drawings and specified.\n 3 Each Block
27 1.26 Construction of block of Covered ACCN for fire fighiting truck/2000 Ltr water Boser complete all as shown on drawings and specified.\n 1 Each Block
28 1.27 Construction of block of Covd accn for Jonga /Gypsy /Jeep (23 Nos) and 01 LT AMB (Block of 06 Veh) complete all as shown on drawings and specified.\n 4 Each Block
29 1.28 Construction of block of Covd Accn for lorry 3/5/7.5 ton ALS MK-III / AMB (block of 07 Veh) complete all as shown on drawings and specified.\n 2 Each Block
30 1.29 Construction of block of Covd Accn for Army Bus /Tatra (Block of 06 Veh) complete all as shown on drawings and specified.\n 1 Each Block
31 1.3 Construction of block of Repair bay with 07 bays and inspection pit(02 N0s) . complete all as shown on drawings and specified.\n 1 Each Block
32 1.31 Construction of block of MT store and Driver changing room complete all as shown on drawings and specified.\n 1 Each Block
33 1.32 Construction of block of MI Room complete all as shown on drawings and specified.\n 1 Each Block
34 1.33 Construction of block of Garrage for Ambulance -01 No and scooter 20 Nos complete all as shown on drawings and specified.\n 1 Each Block
35 1.34 Construction of block of ORs institute complete all as shown on drawings and specified.\n 1 Each Block
36 1.35 Provn of Static water tank 50 kl capacity complete all as specified and shown in Drg No TD-178. 1 Each
37 1.36 Provn of Sentry post complete all as specified and shown in Drg No TD-459. 1 Each
38 1.37 Provn of Incinerators complete all as specified and shown in Drg No TD-585 sheet no. 1/2 & 2/2. 1 Each
39 1.38 Provn of Garbage Bin complete all as specified and shown in Drg No LZ/C-TD/370. 1 Each
40 1.39 Provn of Alarm post complete all as specified and shown in Drg No TD/669. 1 Each
41 1.4 Provn of Ramp(Double) complete all as specified and shown in Drg No LZ/C-TD/148. 2 Each
42 1.41 Provn of washing platform complete all as specified and shown in Drg No TD-411. 7 Each
43 1.42 Provn of Pump House complete all as specified and shown in Drg No STD/168, sheet no. 1/2 & 2/2. 1 Each Block
44 1.43 Provn of RCC over head tank of 30000 gallon capacity complete all as specified and shown in Drg No PB/966 sheet no. 1/3, 2/3(R) & 3/3 1 Each
45 1.44 Provn of Flag mast at guard house complete all as specified and shown in Drg No TD-638. 1 Each
46 2 Total amount of Sch 'A' Part II (Site clearance, excavation and earth work) 1 Lump Sum
47 3 Total amount of Sch 'A' Part III (Internal Water Supply) 1 Lump Sum
48 4 Total amount of Sch 'A' Part IV (Internal Electrification) 1 Lump Sum
49 5 Total amount of Sch 'A' Part V (Road, Path and Culvert) 1 Lump Sum
50 6 Total amount of Sch 'A' Part VI (Area Drainage) 1 Lump Sum
51 7 Total amount of Sch 'A' Part VII (Compound Wall, Fencing & Gate) 1 Lump Sum
52 8 Total amount of Sch 'A' Part VIII (Sewage Disposal) 1 Lump Sum
53 9 Total amount of Sch 'A' Part IX (Lightening Protection) 1 Lump Sum
54 10 Total amount of Sch 'A' Part X (Conduit for Telephone/TV) 1 Lump Sum
55 11 Total amount of Sch 'A' Part XI (Solar Water Heater) 1 Lump Sum
56 12 Total amount of Sch 'A' Part XII (External Water Supply) 1 Lump Sum
57 13 Total amount of Sch 'A' Part XIII (External Electrification) 1 Lump Sum
58 14 Total amount of Sch 'A' Part XIV (Rain water harvesting) 1 Lump Sum
59 15 Total amount of Sch 'A' Part XV (Arboriculture) 1 Lump Sum
60 16 Total amount of Sch 'A' Part XV (Dismantling/Demolition) 1 Lump Sum
61 17 (Provisional sum of Rs 25600000.00 ) for :-\n(i) Provision Aprons and assembly area including necessary earth work complete all as specified and shown in Drg No TD-944 Sh 1/2 &2/2 . - (2562.68 Sqm)\n(ii) Provn of 27 mtr small range including necessary earth work complete all as specified and shown in drg No TD-174, sheet No 1/1. - (01 No)\n(iii) Provn of Parade ground complete all as specified and directed. - (12500 sqm)\n(iv) Provn of Football & Hockey play ground complete all as specified and shown in Drg No TD-638. - (02 Nos)\n(v) Provn of Basketball ground complete all as specified and shown in Drg No TD-638. - (02 Nos)\n(vi) Provn of Volleyball ground complete all as specified and shown in Drg No TD-638. - (02 Nos)\n(vii) Provn of Badminton court complete all as specified and shown in Drg No LZ/C-TD/147, sheet no. 1/1. - (01 Nos)\n(viii) Provn of Fire fighting points complete all as specified and shown in Drg No TD-713. - (01 No) ( ix) Provn of hardstanding for two cars including necessary earth work complete all as specified and shown in drg No TD-666, sheet No 1/1. - (01 No) (x) Provn of hardstanding including necessary earth work complete all as specified and shown in drg No TD-666, sheet No 1/1. - (40.00 Sqm) (xi) Consturction of 7.50 mtr long, 450 mm dia RCC class NP-2 hume pipe culverts with brick masonry including necessary earth work complete all as specified and shown in Drg No TD-575 - (12 Nos) (xii) Construction of RCC slab culvert 9.00 mtr long with 600 mm span with brick masonry including necessary earth work complete all as specified and shown in drg No TD-575, sheet No 2/2. - (10 Nos) (xiii) Construction of RCC slab culvert 9.00 mtr long with 1500 mm span with brick masonry including necessary earth work complete all as specified and shown in drg No TD-575, sheet No 2/2. - (04 Nos) (xiv) Provn of Dhobi ghat with 10 stones complete all as specified and shown in Drg No STD/147, sheet no. 1/2 & 2/2. -01 No 1 Lump Sum
62 18 Schedule 'A' Part - XVII (Miscellaneous Items for B/R & E/M Works)\nNote - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 signifies this fact only. \n
63 18.01 INTERNAL ELECTRIFICATION\nPoint wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.\nNote :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. 2702 Per Point
64 18.02 Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insulated and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.\nNote :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.\n 309 Per Point
65 18.03 Point wiring complete for one bell/buzzer point controlled by one push button on the same board with other switches, with PVC insulated and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.\nNote :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. 4 Per Point
66 18.04 Point wiring complete for One light point controlled by two way switches with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.\nNote :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. 16 Per Point
67 18.05 Point wiring complete with PVC insulated and unsheathed, FRLS cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floor slab & ceiling, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.\nNote :- In case of roof/ceiling, heavy duty pipe shall be used without any extra cost. 188 Per Point
68 18.06 Point wiring complete for one light / fan / exhaust fan controlled by one modular switch with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed.\nNote :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost. 149 Per Point
69 18.07 Point wiring complete for one 5 Pin 5 Amp modular socket outlet point on an indpt with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed.\nNote :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost. 22 Per Point
70 18.08 Point wiring complete for one bell / buzzer point controlled by one modular bell push button on the same board with other switches with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed.\nNote :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost. \n 1 Per Point
71 18.09 Point wiring complete for one 5 Pin 15 Amp modular socket outlet point on an indpt board with PVC insulated and unsheathed FRLS cable 2.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed.\nNote :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost. 8 Per Point
72 18.1 Switch flush type 5/6 Amps single pole Two way complete all as specified and directed.\n 16 Each
73 18.11 Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed.\n 171 Each
74 18.12 Modular switch 1 way 16A, 1 module, 240 Volts complete all as specified and directed.\n 4 Each
75 18.13 Modular socket 6 A, 5 Pin combined 2 module complete all as specified and directed.\n 22 Each
76 18.14 Modular socket 6/16 A, 5 Pin combined 2 module complete all as specified and directed.\n 4 Each
77 18.15 Modular bell push one module flush type 5 complete all as specified and directed.\n 1 Each
78 18.16 Modular Fan step regulator, 120W 2 module as required complete all as specified and directed.\n 32 Each
79 18.17 Blanking plate for one module complete all as specified and directed.\n 30 Each
80 18.18 Supply and fixing modular type 20 Amps power unit for controllig power equipments including power socket and 20 Amp SP MCB complete all as specified and directed by Engineer-In- Charge.Make:Havells cat part No-AHL0202504 or technocommercially equivalent in SIEMENS. 24 Each
81 18.19 S & F AC three phase static energy meter of accuracy class 1.0,3x240 Volt,50 Hz with backlit LCD display of rating 10-60 A (Measures & displays kWh,VI,kW,PF,Hz,last month history of kWh & MD in kW) with special features like TOD,Tamper logging,optical communication port & display in absence of power with transparent hinge type box complete all as specified and directed. 1 Each
82 18.2 Supply and fix AC single phase static energy meter of Accuracy class 1.0 ,240 V with backlit LCD display of rating 5-30 A and with 1 push button(measures & display Kwh,kvah,VI,PF,Frequency,KW,KVA,six months history of energy & MD IN kw & kva with transparent hinge type box complete . 8 Each
83 18.21 Supply and fix led 10 to 20 watt spot bed light light fixed on wall complete all as specified and directed.MakePHILIPS/CROMPTON 239 Each
84 18.22 New generation, post top, energy saving LED 25 WATT, 5700K aesthetically designed with symmetric light distribution including minimum half meter pole of suitable size dia grouted in PCC and cable connection by means of 3 core 1.5 sqmm copper conductor complete all as specified and directed.\nMake: CAT PART NO - LHEVBHP7PN6K025 of Havells /PHILIPS/BAJAJ or equivalent model of makes mentioned in Appendix 'D'.\n 4 Each
85 18.23 S&F Exhaust Fan high quality engineering plastic, resistant to colour change with anti- statio properties (ventil air) 200 mm sweep with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from celling rose to exhaust fan motor complete all as specified and directed. Make- Havells Model -Ventil Air -DX White or equivalent model of makes mentioned in Appendix 'D'.\n 5 Each
86 18.24 S&F Exhaust Fan high quality mettalic body, resistant to colour change 450 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from celling rose to exhaust fan motor complete all as specified and directed. Make- Bajaj model No Supreme Dlx or equivalent model of makes mentioned in Appendix 'D'. 5 Each
87 18.25 S&F Exhaust Fan high quality mettalic body, resistant to colour change with anti- statio properties (ventil air) 300 mm sweep 60 watt ,1380 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from celling rose to exhaust fan motor complete all as specified and directed. Make- Baja model-Freshee MK II or equivalent model of makes mentioned in Appendix 'D'. 110 Each
88 18.26 Supply and fix air circulator wall fan 400 mm sweep complete all as specified and directed.Make BAJAJ Model -ESTEEM or equivalent model of makes mentioned in Appendix 'D'. 50 Each
89 18.27 Energy saving pressure die-cast aluminium IP 66 roadway luminaire with high power 14 WATT LED with a nominal system output of 85 lum/watt(min) with PF not less than 0.9 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia/suitable dia light grade bend to shape security light fitting with necessary MS clamps 35/40 mm wide and 6 mm in thickness in suitable length not more than 30 CM and Max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminium paint including nuts, bolts and washers complete all as specified and directed. Make Philips cat part No BRP022 P LED 14 CW MR S1 PSU GR P3635 or equivalent model of makes mentioned in Appendix 'D'. 158 Each
90 18.28 Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 11 Watt LED warm white in colour with a nominal system output of 120 lum/watt(min) with PF not less than 0.9 complete all as specified and directed. 66 Each
91 18.29 Ceiling fan 1200 mm sweep single phase 230V AC, five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including provn of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 mtr long for connection complete all as specified and directed.\nMake: Bajaj model Electra 50 or equivalent model of makes mentioned in Appendix 'D'. 519 Each
92 18.3 S&F MCB 6-32 Amps 3 pole,240V/415 V,50 Hz ,AC with breaking capacity 10 KA ,complete all as specified and directed. 12 Each
93 18.31 MCCB 3 pole,415 V ,AC fixed thermal & fixed magnetic setting 63 amps with breaking capacity 10 KA . Ics=100% complete all as specified and directed. 11 Each
94 18.32 MCCB 3 pole,415 V ,AC fixed thermal & fixed magnetic setting 100 amps with breaking capacity 10 KA . Ics=100% complete all as specified and directed. 2 Each
95 18.33 MCCB 3 pole,415 V ,AC fixed thermal & fixed magnetic setting 125 amps with breaking capacity 10 KA . Ics=100% complete all as specified and directed. 1 Each
96 18.34 MCCB 3 pole,415 V ,AC fixed thermal & fixed magnetic setting 200 amps with breaking capacity 35 KA Ics=100% complete all as specified and directed. 1 Each
97 18.35 MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCCB and with enclosure blank plates for unused way suitable for 4 ways complete all as specified and directed. 15 Each
98 18.36 MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCCB and with enclosure blank plates for unused way suitable for 6 ways complete all as specified and directed. 12 Each
99 18.37 MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.\n 38 Each
100 18.38 MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 6 way complete all as specified and directed.\n 62 Each
101 18.39 MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed.\n 43 Each
102 18.4 MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed.\n 13 Each
103 18.41 MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 16 way complete all as specified and directed.\n 1 Each
104 18.42 MCB single pole 6 amp to 20 Amp rating 'B' Series,10 KA 240 Volts,AC complete all as specified and directed.\n 682 Each
105 18.43 MCB single pole 40amp to 63 Amp rating 'B' Series,10 KA 240 Volts,AC complete all as specified and directed.\n 42 Each
106 18.44 MCB single pole and nutral 10amp to 32 Amp rating 'B' Series,10 KA 240 Volts,AC complete all as specified and directed.\n 148 Each
107 18.45 MCB single pole and nutral 40 amp rating 'B' Series, 10 KA, 240 Volts, AC complete all as specified and directed.\n 6 Each
108 18.46 Submain wiring with two single core 4 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including 4 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. \nNote:- Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit.\n 2969 Running Metre
109 18.47 Submain wiring with two core 6 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including one 4 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. \nNote:- Two single core 6 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit.\n 228 Running Metre
110 18.48 M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.00 mm dia galvanised iron or steel wire complete all as specifed and directed. 50 Running Metre
111 18.49 Glaze wall light decorative wall mounting fixture in durable plastic gold finish including 0.5 watt green and red LED lamp complete all as specified and directed. \nMake: Havells cat part No-LHFOECE1TZ1B014 or equivalent model of makes mentioned in Appendix 'D'.\n 4 Each
112 18.5 Supply and fix pressure die cast aluminium housing flood light of 30 watt having lumen output not less than 120 lumen per watt cvomplete.Make Havells cat part No JETA QUANTO 30 or equivalent model of makes mentioned in Appendix 'D'.\n 42 Each
113 18.51 S&F suspended LED 20 Watt pre wired 4 feet retrofit type tubelight fitting which provides soft light and glare free symmetrical illumination complete all as specified and directed by Engineer -In-Charge.Note:The cost of two nos MS conduit of suitable length upto 1.5 meter with and including fixing arrangements for each fitting is deemed to be included in quoted rates. Make-HAVELLS cat part No LUMLINE PLUS 20 W or equivalent model of makes mentioned in Appendix 'D'. 806 Each
114 18.52 S&F energy saving sleek and light weight LED batten with high brightness 20 watt LED rod retrofit type with a nominal system output of 85 lim/watt(min) with PF not less than 0.9 providing homogenous illumination, suitable for surface mounting with 4000K integrated high efficiency LED drive>85% non corrosive complete. Make-HAVELLS cat part No LUMLINE PLUS 20W/ or equivalent model of makes mentioned in Appendix 'D'. 38 Each
115 18.53 S&F energy saving 2 feet LED batten with high brightness 9 Watt LED retrofit rod with a nominal system output of 85 lim/watt(min) with PF not less than 0.9 providing homogenous illumination, suitable for surface mounting with 4000Kintegrated high efficiency LED drive>85% non corrosive complete. Make- Make-HAVELLS cat part No LUMLINE 9W/ or equivalent model of makes mentioned in Appendix 'D'. 472 Each
116 18.54 INTERNAL WATER SUPPLY\nCP wall mixer of size 15mm, 3 in 1 with hand shower complete all as specified and directed.\n 20 Each
117 18.55 Health faucet (1.5m tube) with hook (hand spray) with CP body , complete all as specified and directed.\n 20 Each
118 18.56 EXTERNAL WATER SUPPLY Construction of fly ash brick masonry valve pit chamber of size 1050 mm X 1050 mm X 1050 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 leavers and in duplicate key (Make - Godrej ) or equivalent make as approved by GE complete including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.\n 3 Each
119 18.57 Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 leavers and in duplicate key (Make - Godrej ) or equivalent make as approved by GE complete including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed. 8 Each
120 18.58 Drilling /Boring hole under existing road for laying GI pipe of dia 80/100 mm as per required depth complete all as specified and directed. 15 RM
121 18.59 Disconnecting and taking up or down old existing steel tubing of bore 100mm and connections of any description/grade and in any position in trenches/under floors/on walls etc including connected fittings/ accessories all as directed and specified. 100 RM
122 18.6 Disconnecting and taking up or down old existing steel tubing of bore 200mm and connections of any description/grade and in any position in trenches/under floors/on walls etc including connected fittings/ accessories all as directed and specified. 100 RM
123 18.61 Laying only old steel water tubing of any size up to 100mm bore and connections of any description/any grade and in any position obtained from taking downon new route in trenches with using new fittings i.e. bends/Tee/ sockets/ reducers/elbow etc. including cutting/making new threads at the ends of old pipes all as specified and directed: 100 RM
124 18.62 Laying only old steel water tubing of any size up to 200mm bore and connections of any description/any grade and in any position obtained from taking downon new route in trenches with using new fittings i.e. bends/Tee/ sockets/ reducers/elbow etc. including cutting/making new threads at the ends of old pipes all as specified and directed: 100 RM
125 18.63 EXTERNAL ELECTRIC SUPPLY :\nSupply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-55, 11 mtr long, all as specified and shown on drawings including the followings:-\n(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points.\n(b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work.\n(c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work.\n(d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base.\n(e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.\n(f) Painting of coping shall be cement base paint complete all as directed.\n(g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed.\nNote:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.\n 2 Each
126 18.64 Supply installation, commissioning and testing of transformer copper wound step down 400 KVA out door type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed naturally cooled, delta connected on HV side and star connected in LV side in accordance with vector symbol DY-II with neutral brought out on secondary side and having tapping in step of ± 2 ½ %, ± 5% and ± 7 ½ % to be changed by mean of hand operated OFF load tap changing gear including first fill of transformer oil as per IS-335, and including all fittings/accessories as specified in SSR Part I and IS-1180,1993 or as per latest, the transformer should have cable box on LT side and exposed brass bushings on HT side, oil temprature gauge,dehydrating breather with first fill of dehydrating agent, oil conservator tank, explosion vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthings terminals for neutral and body ,PCC foundation complete in all respect and all other standard accessories etc all as specified and directed. The transformer shall be complete in all respect and all other standard accessories etc all as specified with following accessories consisting as per details mentioned in Annexure - A to BOQ.\nNOTE :- (i) Annexure- A to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.\n(ii) Drawing should be approved by GE before placing the order.\n(iii)Transformer shall be platform mounted as per TD No 699 and the rates quoted against this item shall be deemed to include for this provision.\n(iv) The contractor shall arrange factory visit as detailed by accepting officer to check the above system.\n 1 Each
127 18.65 Supply, laying, jointing, testing and commissioning of HT XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium stranded conductor 11 KV 'Earthed' grade conforming to IS 7098 (Part II) through pipes/ducts/trenches/under floor/under road of size 95 Sqmm 3 core complete all as specified and directed. 600 Running Metre
128 18.66 HT pin type insulator porcelain vitreous white, brown or green including one galvanised mild steel spindle, two GI washer and one GI nut of size 150 mm height, 150 mm dia for 11000 Volt grade complete all as specified and directed.\n 9 Each
129 18.67 Lightning arrestor non linear resistor type or expulsion type conforming to IS-3070 (Part-I) complete line discharge or transmission class - 2 nominal discharge current 10 KA & high discharge 100 KA assembly suitable for 11 KV incl all clamps, nuts, bolts & washers and connecting to earth with 32x6 mm size GI strip complete all as specified and directed. 2 Set of 3 Nos
130 18.68 Supply installation, commissioning and testing of switch air break gang operated HT 11 KV triple pole with 12 Nos insulator of 200 amp rating with drop out fuse assembly with fuse carrier, fuse element mounted on insulator and steel frame mechanically (horizontally), vertically operated with operating rod of 25 mm bore medium grade GI pipe of suitable length, worked from ground level and with locking arrangement flat iron clamp of size 50 mm x 6 mm including MS channel of suitable size and length for fixing GOD/DO including bolts, nuts, and washers etc. complete all as specified and directed.\nNote:- MS work shall be measured and paid separately. 2 Each Set
131 18.69 Supplying, fixing, jointing and testing cable jointing kit for 11 KV (earthed) grade cable for straight through cold shrink type joint complete with jointing materials and accessories suitable for HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed. 1 Each
132 18.7 Supplying, fixing, jointing and testing cable jointing kit for 11 KV (earthed) grade cable for outdoor termination cold shrink type joint complete with jointing materials and accessories suitable for HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed. 4 Each
133 18.71 LED street light Integral type luminaire 70/75 watt , comprising of PDC housing , enclosed with toughened glass cover suitable for & including 50 mm OD GI pipe not less than 1.2 mtr long bent to shape bracket , Ingress protection-66 complete all as specified and directed.\nMake : Surya cat part No. SLE UL 72W IP-66 LXN or equivalent model of makes mentioned in Appendix 'D'.\n 50 Each
134 18.72 S&F MS junction box of size 250x200x150 mm made out of MS sheet 16 gauge, duly powder coated ( inside / out side ) complete including MCB SP 16 Amp with 4 Nos Aluminium bus bars of 25 mm x 3 mm size, fixed on porcelain support with hinged cover & locking arrangement fixed to electric pole by means of clamps of MS flat iron 25 x 5mm with bolts & nuts complete including electric connection with copper wire of size 1.5 sqmm 2 single core from MS junction to each fitting complete all as specified & directed. 50 Each
135 18.73 Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, all as specified and shown on drawings including the followings:-\n(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. \n(b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. \n(c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. \n(d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base.\n(e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.\n(f) Painting of coping shall be cement base paint complete all as directed.\n(g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed.\nNote:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately. 50 Each
136 18.74 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 300 Sqmm 3.5 core complete all as specified and directed. 40 Running Metre
137 18.75 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 240 Sqmm 3.5 core complete all as specified and directed. 310 Running Metre
138 18.76 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 185 Sqmm 3.5 core complete all as specified and directed. 565 Running Metre
139 18.77 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 150 Sqmm 3.5 core complete all as specified and directed. 478 Running Metre
140 18.78 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 95 Sqmm 3.5 core complete all as specified and directed. 500 Running Metre
141 18.79 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 70 Sqmm 3.5 core complete all as specified and directed. 225 Running Metre
142 18.8 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 50 Sqmm 3.5 core complete all as specified and directed. 530 Running Metre
143 18.81 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 35 Sqmm 3.5 core complete all as specified and directed. 290 Running Metre
144 18.82 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 25 Sqmm 4 core complete all as specified and directed. 480 Running Metre
145 18.83 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 16 Sqmm 4 core complete all as specified and directed. 3224 Running Metre
146 18.84 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 16 Sqmm 2 core complete all as specified and directed. \n 910 Running Metre
147 18.85 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 4 core complete all as specified and directed. 50 Running Metre
148 18.86 Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 2 core complete all as specified and directed. 260 Running Metre
149 18.87 Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. \nNote:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.\n(ii) Earthing strip beyond 7.5m shall be measured and paid separately.\n 88 Each Job
150 18.88 Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick,latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc (For Transformer) and comprising of the following accessories consisting as per details mentioned in Annexure - B to BOQ.\nNOTE :- (i) Annexure- B to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.\n(ii) Drawing should be approved by GE before placing the order. \n 1 Each Job
151 18.89 Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick/latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc, ( For PANEL No1.) and comprising of the following accessories consisting as per details mentioned in Annexure - C to BOQ.\nNOTE :- (i) Annexure- C to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.\n(ii) Drawing should be approved by GE before placing the order. \n 1 Each Job
152 18.9 Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick,latest CPRI approved thick duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc( For Panel 2) and comprising of the following accessories consisting as per details mentioned in Annexure - D to BOQ.\nNOTE :- (i) Annexure- D to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.\n(ii) Drawing should be approved by GE before placing the order. \n 1 Each Job
153 18.91 Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick , latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc and comprising of the following accessories consisting as per details mentioned in Annexure - E to BOQ.\nNOTE :- (i) Annexure- E to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.\n(ii) Drawing should be approved by GE before placing the order. \n 1 Each Job
154 18.92 Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick , latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc and comprising of the following accessories consisting as per details mentioned in Annexure - F to BOQ.\nNOTE :- (i) Annexure- F to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.\n(ii) Drawing should be approved by GE before placing the order. \n 1 Each Job
155 18.93 Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick , latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc and comprising of the following accessories consisting as per details mentioned in Annexure - G to BOQ.\nNOTE :- (i) Annexure- F to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.\n(ii) Drawing should be approved by GE before placing the order. \n 1 Each Job
156 18.94 Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick , latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc and comprising of the following accessories consisting as per details mentioned in Annexure - H to BOQ.\nNOTE :- (i) Annexure- F to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.\n(ii) Drawing should be approved by GE before placing the order. \n 1 Each Job
157 18.95 Solar street light system including galvanised steel pole with 18 watt LED type with lead acid 12 volt, 100 AH, battery, automatic ON-OFF system, charge controller complete & installation, commissioning including material and labour for masonry work complete all as specified and directed.\n\n 30 Each
158 18.96 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine with and including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. 12 RM
159 18.97 Disconnection and taking out old serviceable LT cable of any size and staking of old bricks for reuse complete all as specified and directed.\nNote: Earth work will be paid separately. 300 RM
160 18.98 Cast iron route indicator of 100 mm dia mark for HT line 11 KV UG cable fixed on 2 fit long MS angle 25x3 mm bend to shape including connected etc & PCC work painting with one coat of red oxide primer and two coat of red paint before fixings complete all as specified and directed.\n 200 Each
161 18.99 LIGHTENING PROTECTION :\nEarthing for machinery, equipments transformer body, transformer neutral, LT feeder pillar box complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not 1ess than 2. 25 mtr below normal GL with the top edge of the plate not less than 1.5 mtr below the ground level connected by GI strip of size 32 x 6 mm thick soldered and revetted to earth plate. Complete with watering pipe 20 mm bore GI pipe (light grade) and chamber PCC (1:4:8) type D2 using 40 mm grade stone aggregate, coping shall be PCC (1:3:6) type C-1 using 20 mm graded stone aggregate and RCC (1:2:4) type B1 using 20 mm graded stone aggregate pit cover 50 mm thick reinforced with 8mm tor MS bar at 80 mm c/c both way including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No . 3 of SSR part and as specified including earth plate packed all sides with charcoal dust, common salt and testing complete including GI sheet funnel, wire mesh etc complete all as specified and directed and testing on completion. \nNote:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. 28 Each
162 19 Protection insulator for fixing of aluminium strip 200 RM
163 19.01 REFRIGERATOR/ WATER COOLER/ DESERT COOLER/SOLAR WATER HEATER :\nRefrigerator of capacity 192 liter, electric driven, single phase, 230 volt, AC, 50 Hz 5 star rated including plug top 15 Amps and necessary electric connection complete all as specified and directed.\n\n 6 Each
164 19.02 Refrigerator of capacity 195 upto 310 liter, electric driven, single phase, 230 volt, AC, 50 Hz 5 star rated including plug top 15 Amps and necessary electric connection complete all as specified and directed.\n\n 3 Each
165 19.03 Supply, installation, commissioning of Water cooler fully Stainless steel, electric driven single phase having storage capacity 80 Ltrs & and nominal cooling capacity 40 Ltrs per hour including connection by means of water pipe line, inlet and outlet, PVC pipe connection with brass coupling, nuts at both ends and other necessary fittings including necessary electric connection with and including plug top 15 Amps from voltage stabilizer to water cooler complete all as specified and directed. \n\n 24 Each
166 19.04 Metallic body desert cooler electric driven (single phase) having nominal air flow of capacity 4000 Cum/hour, including water pipe connection with PVC pipe connection having brass coupling nuts at both ends and PVC float valve and other necessary fittings and electric plug connection with and including plug top 5 Amps complete all as specified and directed. \n\n 47 Each
167 19.05 Voltage stabilizer of capacity 1.0 KVA for automatic operation, single phase naturally air cooled indoor type and designed for input voltage between 170 Volt to 250 Volt with output voltage stabilized at 230 Volts with accuracy of +/- 2.5 % complete all as specified and directed.\n\n\n 24 Each
168 19.06 Voltage stabilizer of capacity 5.0 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input voltage between 170 Volt to 250 Volt with output voltage stabilized at 230 Volts with accuracy of +/- 2.5 % complete all as specified and directed.\n 9 Each
169 19.07 Supply and install of solar water heating system consisting of flat plate collector box fabricated from aluminium extruded partition by means of gas welding or brazing leak proof fully insulated with glass wool (48 Kg/Cum) with supporting structure duly paint with synthetic enamel black paint over a coat of zinc chromate Red Oxide primer provided with absorber made from copper sheet and copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minium 20 SWG thickness with puff insulation of minium 50mm girth outer including of 55-26 SWG brass socket and nipple fully insulated with glass wool with cold and hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming of IS-12933 & 12976 with necessary wiring fixed on and including required size PCC platform, cold water tank & make up water tank of capacity 300 liter per day capable to supply hot water at 60 degree celsius complete with 2 kw electric backup including PVC storage water tank three layer of capacity 500 litre for cold water of solar water heater with built up steel stage made of 25x3 mm angle frame of sufficient height complete all as specified and directed. \n\n 6 Each
170 19.08 Supply and install of solar water heating system consisting of flat plate collector box fabricated from aluminium extruded partition by means of gas welding or brazing leak proof fully insulated with glass wool (48 Kg/Cum) with supporting structure duly paint with synthetic enamel black paint over a coat of zinc chromate Red Oxide primer provided with absorber made from copper sheet and copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minium 20 SWG thickness with puff insulation of minium 50mm girth outer including of 55-26 SWG brass socket and nipple fully insulated with glass wool with cold and hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming of IS-12933 & 12976 with necessary wiring fixed on and including required size PCC platform, cold water tank & make up water tank of capacity 200 liter per day capable to supply hot water at 60 degree celsius complete with 2 kw electric backup including PVC storage water tank three layer of capacity 500 litre for cold water of solar water heater with built up steel stage made of 25x3 mm angle frame of sufficient height complete all as specified and directed. \n 3 Each
171 19.09 Supply and install of solar water heating system consisting of flat plate collector box fabricated from aluminium extruded partition by means of gas welding or brazing leak proof fully insulated with glass wool (48 Kg/Cum) with supporting structure duly paint with synthetic enamel black paint over a coat of zinc chromate Red Oxide primer provided with absorber made from copper sheet and copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minium 20 SWG thickness with puff insulation of minium 50mm girth outer including of 55-26 SWG brass socket and nipple fully insulated with glass wool with cold and hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming of IS-12933 & 12976 with necessary wiring fixed on and including required size PCC platform, cold water tank & make up water tank of capacity 100 liter per day capable to supply hot water at 60 degree celsius complete with 2 kw electric backup including PVC storage water tank three layer of capacity 200 litre for cold water of solar water heater with built up steel stage made of 25x3 mm angle frame of sufficient height complete all as specified and directed. \n 11 Each
172 19.1 RAIN WATER HARVESTING (E/M Part)\nPlain PVC Pipe, 100 mm dia bore as per IS 12818 including lowering and jointing complete all as specified and directed. 126 RM
173 19.11 Screened PVC Pipe 100 mm dia bore as per IS 12818 including lowering and jointing complete all as specified and directed. 36 RM
174 19.12 Boring 200 mm dia size bore through any kind of soil/ strata by direct rotary method up to and including 90 mtr depth complete all as specified and directed.\n 162 RM
175 19.13 Reaming of bore upto 300 mm ( only for recharge well) pilot bore in any kind of soil/ strata including hard stone/boulder by means of direct rotary method complete all as specified and directed.\n 162 RM
176 19.14 Pea Gravel packing for trial bores of size to be designed by the contractor natural shape brought direct from river bed and packing around the casing pipe to entire depth upto ground level complete all as specified and directed.\n 9 Cum
177 19.15 Development of bore wells by means of high velocity jetting together with air compressor having capacity not less than 100 PSI for pumping out mud/ dirty water complete all as specified and directed.\n 60 Per Hour
178 19.16 PVC end cap for 100 mm bore pipe complete all as specified and directed.\n 3 Each
179 19.17 Plain PVC bend 87.5 degree for 100 mm bore pipe, with nylon wiremesh for to covering one end complete all as specified and directed.\n 3 Each
180 19.18 Piezometer (Steel Tape 25 mm wide and 50 meter long with plumb) complete all as specified and directed..\n 3 Each
181 19.19 BORE WELL :\nDrilling vertical bore 200 mm dia, from 0 to 60 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.\n\n 60 Running Metre
182 19.2 Drilling vertical bore 200 mm dia, exceeding 60 Mtr but not exceeding 200 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.\n 140 Running Metre
183 19.21 Drilling vertical bore 200 mm dia, exceeding 200 Mtr but not exceeding 300 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.\n 100 Running Metre
184 19.22 Drilling vertical bore 200 mm dia, exceeding 300 Mtr but not exceeding 480 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.\n 180 Running Metre
185 19.23 Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 675 mm/525mm , from 0 to 75 Mtr deep below ground level of reaming 675 mm size including all works pertain to boring complete all as specified and directed.\n 75 Running Metre
186 19.24 Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, exceeding 75 Mtr but not exceeding 200 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed. 125 Running Metre
187 19.25 Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, exceeding 200 Mtr but not exceeding 300 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed. 100 Running Metre
188 19.26 Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, exceeding 300 Mtr but not exceeding 480 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed. 180 Running Metre
189 19.27 Mild steel sheet casing plain ERW casing pipe 350 mm bore, 8 mm thickness, conforming to IS: 4270 -2001, ISI marked, lowering and fixing in position upto required depth in all strata cut into different length including cutting, welding pipe jointed and welded coupler rings through out circumference of the pipe and coupler rings both side as in bore wells complete all as specified and directed. \nNOTE :- (i) Length of each pipe shall not be less than 2.4 metre except where pipe length required is less than 2.4 meters. (ii) Welding shall be done through out the circumference of the pipe and coupler rings both side. 70 Running Metre
190 19.28 Mild steel sheet casing ERW pipe 200 mm bore, 8 mm thickness conforming to IS: 4270 -2001, ISI marked complete and lowering and fixing in position cut into different length including cutting, welding pipe, jointed and welded coupler rings throughout the circumference of after reducing socket 350mm x 200mm bore complete all as specified and directed. \nNote:- Reducing socket shall be measured and paid seperately. 360 Running Metre
191 19.29 V-Strainer (Johnson screen pipe) of size 200 mm bore of thickness 8mm and maximum length of stainer 3 mtr long/ 6 mtr long low carbon galvanised steel, plain beveled ends in built welding slots of size 0.75 mm wide uniformly distributed on surfaces and fixed in position cut into different length including cutting, welding pipe, jointed and welded coupler rings throughout the circumference of pipe complete all as specified and directed. 50 Running Metre
192 19.3 Mild steel reducing socket of size 350 mm x 200 mm including welding MS strip of size 40 x 6 mm (02 Nos) on each joint extended 100 mm on each side complete all as specified and directed.\nNote:- The wall thickness of the Socket side shall not be less than 7.04 mm.\n 1 Each
193 19.31 Well cap of 350 mm dia and 8 mm thick size on top of the pipes with locking arrangement complete all as specified and directed. 1 Each
194 19.32 Mild steel bail plug 200 mm size, 10 mm thick of 1 mtr long with MS rod 25 mm dia size welded to it at bottom bail hook complete all as specified and directed.\n 1 Each
195 19.33 Pea gravel of size 3 mm to 6 mm size of approved quality as order to pack around the casing/ slotted pipes in bore well to entire depth upto ground level complete all as specified and directed. 135 Cum
196 19.34 MS flat iron (Two nos) 150 mm x 16 mm thick size clamp for holding with 350 mm bore housing pipe including casting PCC block of size 1200 mm x 1000 mm x 1000 mm in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate including 150 mm bore MS pipe two Nos each 1.5 Mtr long with cap plug and cap top for feeding pea gravel for each bore well complete all as specified and directed.\n 1 Each Job
197 19.35 Mild Steel black column pipe 3 mtr long heavy duty 150 mm bore wall thickness 5.4 mm both end flanged with heavy duty MS flange not less than 16 mm thick screwed and welded inside and outside. The flange end making surface shall be made smooth including welding of 04 strip of 5.0 mm thick 25 mm wide and 50 mm long covering pipe and both end flanged having 08 Nos predrilled hole not less than 16 mm including rubber gasket, nut bolts and washer. Pipe shall be duly painted with anti-corrosive paint complete all as specified and directed. 60 Running Metre
198 19.36 Strata sample box with glass cover 3 mm thick having internal dimension 1000 mm x 600 mm x 100 mm made out of 20 mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various starta met in boring including strata chart in duplicate complete all as specified and directed.\n 1 Each Job
199 19.37 Yield testing for the bore well with the help of 'V' notch tank 90 degree by continuosly pumping for 16 hours as well as to detemine the safe pumping yield capacity of tube well shall be carried out as per IS, complete all as specified and directed.\nNote:- Cost of pumping including necessary T&P required for yield test is included in quoted rate. 1 Each Job
200 19.38 Electric logging in pilot bore for precise delination of granular zones as also the quality of ground water including report interpretation complete all as specified and directed.\nNote : Electric logging shall be carried out by any approved Govt Agency. 1 Each Job
201 19.39 Chemical and bacteriological testing of sample from approved laborateory to ensure potability of water complete all as specified and directed.\n 1 Each Job
202 19.4 Mild Steel centering guide made out of 40x6 mm and 150 mm length MS flat iron complete all as specified and directed. (Centring guide as contained in IS 2800 Part-I of 1991).\n 22 Each
203 19.41 Tail piece made out of MS pipe of size 100 mm X 150 mm, 01 mtr long of wall thickness 5.4 mm both end flanged with suitable MS flange with 08 Nos pre-drilled holes of size 16 mm and welded with 04 Nos strip made out of MS plate of size 5.4 mm thick 25 mm wide and 50 mm long and flanged end pipe shall be duly painted out side only complete all as specified and directed. 1 Each Job
204 19.42 Reflex valve (NRV) both end flanged of size 150 mm (ISI marked) with out by pass arrangement including jointing material, commissioning and testing complete all as specified and directed.\n 1 Each
205 19.43 Cast iron sluice valve of size 150 mm heavy duty both ends flanged class PN 1.6, ISI marked with high tensile brass spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3 mm thick rubber gasket joints etc complete all as specified and directed.\n 3 Each
206 19.44 Submersible cable PVC insulated and PVC sheathed copper conductor of size 16 Sqmm 3 core 1100 volts grade, flat cable conforming to IS 694-1977 including jointing with jointing materials and connections complete all as specified and directed. 130 Running Metre
207 19.45 Pressure feed gasseous chloronome plant with injector panel consisting of gas filling high pressure gauge, stop valve, primary and secondary filter, mixing chamber solutionzer, NRV bend, moisture glass tube, PVC NRV, regulating valve, cylinder connecting valve, cylinder connecting copper pipe and all accessories conforming to IS: 10553 (part-4) complete with booster pumping set 5 HP electric motor driven three phase 400/ 440 volts, 50 Hz, directly coupled to pump with common channel base frame, motor starter, motor connection from starter to motor with three single core copper cable of suitable size including copper lugs, saddles etc, PVC insulated drawn in PVC conduit. All necessary inlet and outlet connection to injector and injector to water line, manufacturer's catalauge spare parts list including necessary foundation with PCC (1:2:4) type B1 with 20 mm graded stone aggregate. The plant should have capacity of injecting 1000 gm chlorine per hour against any pressue line directly complete including supply of one No new chlorine gas cylinder duly filled with 100 kg chlorine gas with control valve, cap etc complete all as specified and directed. 1 Each Job
208 19.46 Pressure gauge 150 mm dia of scale 0 to 7 Kg/ Cm2 with flat iron clamp of size 25X3 mm and 15 mm dia socket complete all as directed. 1 Each
209 19.47 Supply, installation, testing and commissioning of Submersible Pump set with bronze impeller, directly coupled with motor, cast iron body pump, bronze diffusor suitable for 250mm/ 350mm bore hole tube well, water lubricated against total head 90 mtr and discharge 1150 LPM operated on AC 3 Phase 415 Volt minimum motor capacity 30 HP elect supply with and including submersible cable of size 16 sq mm 3 core, two length 5.0 mtr length all as specified and directed. 1 Each Job
210 19.48 Development tube well by compressed air with minimum pressure of 10 kg/sqcm and minimum 450 CFM air compressor until sand free colour potable water up to 10 ppm is obtained to get maximum yield and discharge of bore well all as in IS 11189, Para 4.3 complete all as specified and directed. \nNote:- (i) Compressor, pump, pipe and other allied items will be arranged by contractor and no extra payment will be made by the Dept. 50 Hour
211 19.49 Developing tube wells by over pumping for tube well complete after development by compressor and water shall be used only after receipt of satisfactory test result as per IS, complete all as specified and directed.\nNote:- (i) Over pumping will be carried out by pumping the water at higher capacity i.e. not less than 50% above the yield of bore well.\n(ii) Cost of arranging pump and compressor is deemed to be included in the unit rate quoted.\n\n 150 Hour
212 19.5 Road , Path / Culvert S & F Round pipe delinators with acrylic reflectors of make 'ROAD STAR' (Gogia Plastics) model No/ Cat part No GRD-100P including fixing complete all as specified and directed.. 600 Each
213 19.51 Providing & fixing of Stimsonite Model C-80 'Cat Eye' in size of width not exceeding 130mm and height not exceeding 20mm made of strong engineering high impact resistant polymer with electronic welded lenses for retro reflective in dry and wet weather condition with bituminous adhesive along the road complete all as specified and directed. 2700 Each
214 19.52 Providing & laying 2.5 mm thick hot applied thermoplastic road marking material in uniform thickness with glass beads as per clause 803 of MOST specification . The work includes cleaning of road surfaces, heating the material within the specified temperature complete all as specified and as directed. 1500 Sqm
215 19.53 Retro reflective sign board made of 2mm thick aluminium sheet, fully covered with high intensity grade retro-reflctive sheeting conforming to ASMT-49601 of blue colour and letter & symbols of white colour shall be made with same high intensity grade retro-reflective aluminium sub shade on both sides of size 1000mm x 750mm rectangular shape including frame work with MS hollow tube 25mm x 25mm including painting of MS section complete all as spefied & directed including following items :- (i) Excavation in post holes n exc 0.50 Cum including RFR and removed in soft/loose soil. (ii) PCC 1:4:8 type D-2 as in foundation filling for grouting the pipe. (iii) PCC 1:2:4 type B-2 as in plinth of size0.45m x 0.45m x 0.30m including three coats of white wash. (iv) MS hollow pipes of 50mm x 50mm vertical members including welding of 40x5mm FI of 300mm long one Nos of fastner/hold fast at bottom of hollow pipe including necessary arrangement for fixing the retro-reflective sign board total length of hollow pipe 1.80m above GL and 0.60m below GL including two coats of synthetic enamel paint over one coat of zinc chrome primer on exposed steel surfaces. 40 Each
216 19.54 ARBORICULTURE Supply of green live healthy trees/plants of Asoka plant 2 to 3 feet height and planting the same including excavating the pit of size 600 x 600 x 600 mm for planting of tree/plants, removing of rubbish, kanker etc from the excavated soil and mixing with farm yard manure 0.10 cum per pit and chemical @ 30 ml per pit etc. and refilling the same in the pit and planting the plants/trees etc complete including providing the support of bamboo stick for straightening of the plant and making base around the plant with soil for watering and removal surplus soil to a distance n.exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified and directed. (Manures and chemicals will be paid separately)\n 165 Each
217 19.55 Ditto all as per srl no. 19.54 here-in-before but Juniper plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 135 Each
218 19.56 Ditto all as per srl no. 19.54 here-in-before but Cycus plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 190 Each
219 19.57 Ditto all as per srl no. 18.01 here-in-before but Revenala plant 1 to 2 feet height paid separately)\n 185 Each
220 19.58 Ditto all as per srl no. 19.54 here-in-before but Sacacas Asoka plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 175 Each
221 19.59 Ditto all as per srl no. 19.54 here-in-before but Tabeberia chrysanthar plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 170 Each
222 19.6 Ditto all as per srl no. 19.54 here-in-before but Thevelia pereviana (yellow) 2 to 3 feet heightcomplete all as specified and directed. (Manures and chemicals will be paid separately)\n 150 Each
223 19.61 Ditto all as per srl no. 19.54 here-in-before but Thevelia pereviana (white) 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 130 Each
224 19.62 Ditto all as per srl no. 19.54 here-in-before but Thevelia pereviana (pink) 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 150 Each
225 19.63 Ditto all as per srl no. 19.54 here-in-before but Calliatenon citrilnos plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 160 Each
226 19.64 Ditto all as per srl no. 19.54 here-in-before but Arjun tree 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 170 Each
227 19.65 Ditto all as per srl no. 19.54 here-in-before but Bottle brush plant 3 to 4 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 160 Each
228 19.66 Ditto all as per srl no. 19.54 here-in-before but Royal palm 4 to 5 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 500 Each
229 19.67 Ditto all as per srl no. 19.54 here-in-before but X mass tree 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 60 Each
230 19.68 Ditto all as per srl no. 19.54 here-in-before but Guava plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 190 Each
231 19.69 Ditto all as per srl no. 19.54 here-in-before but Mango (Hibreed) plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 180 Each
232 19.7 Ditto all as per srl no. 19.54 here-in-before but Awla plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 170 Each
233 19.71 Ditto all as per srl no. 19.54 here-in-before but Nimboo (Hibreed) plant 2 to 3 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 160 Each
234 19.72 Ditto all as per srl no. 19.54 here-in-before but Rat ki rani plant 1.5 to 2 feet complete all as specified and directed. (Manures and chemicals will be paid separately)\n 140 Each
235 19.73 Ditto all as per srl no. 19.54 here-in-before but Brunfelsia plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 165 Each
236 19.74 Ditto all as per srl no. 19.54 here-in-before but Crape myrtle 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 165 Each
237 19.75 Ditto all as per srl no. 19.54 here-in-before but Duranta 8 to 10 inches height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 3000 Each
238 19.76 Ditto all as per srl no. 19.54 here-in-before but Plumeria acutifolia 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 130 Each
239 19.77 Ditto all as per srl no. 1 19.54 here-in-before but Sagwan plant 1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 170 Each
240 19.78 Ditto all as per srl no. 19.54 here-in-before but Neem plant1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 150 Each
241 19.79 Ditto all as per srl no. 19.54 here-in-before but Bouganvillaes All colors plant1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 170 Each
242 19.8 Ditto all as per srl no. 19.54 here-in-before but Amaltash (cassica fistula) plant1.5 to 2 feet height complete all as specified and directed. (Manures and chemicals will be paid separately)\n 160 Each
243 19.81 Supply and planting of Arancsiria cookeie plant 2 to 3 feet height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed. 80 Each
244 19.82 Supply and planting of Chinese fan plam 2 to 3 feet height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed. 100 Each
245 19.83 Supply and planting of copper pod plant 2 to 3 feet height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed. 90 Each
246 19.84 Supply and planting of Golden dew drop 8 to 10 inches height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed. 100 Each
247 19.85 Supply and planting of Ixponica 8 to 10 inches height in earthen pot of 10" along with necessary earth work and manure complete all as specified and directed. 100 Each
248 19.86 M & L for surface excavation n.exc 30 cm and avg 10 cm and getting out soft/loose soil, Supplying and laying good quality of approved earth mixed with ganga sand (both equal part) for cultivation purpose, 10cm spread thick ness in true level surface including mixing good quality of approved organic manure @ 0.30 cum/10 sqm and chemical 0.10 Ltrs / per sqm all as specified and supply and plantation of Redis cantia (red) 4 to 6 inches carpet grass including watering and removal surplus soil to a distance n.exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified and directed.\nNote : Farm yard manure and chemical to be measured and paid separately. 1525 Sqm
249 19.87 M & L for surface excavation n.exc 30 cm and avg 10 cm and getting out soft/loose soil, Supplying and laying good quality of approved earth mixed with ganga sand (both equal part) for cultivation purpose, 10cm spread thick ness in true level surface including mixing good quality of approved organic manure @ 0.30 cum/10 sqm and chemical 0.10 Ltrs / per sqm all as specified and supply and plantation of wediha triobata ground cover carpet grass including watering and removal surplus soil to a distance n.exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified and directed.\nNote : Farm yard manure and chemical to be measured and paid separately. 1500 Sqm
250 19.88 Flexible PVC pipes of 20mm dia including reducer connections for gate valve of 25 mm dia bore & ten numbers water sprinklers all as specified and directed (Gate valve catered separately) 350 RM
251 19.89 MS circular flat iron tree guard 60cm dia and 1.50m height above ground level made of 3 No 25 mm x 25 mm x 3 mm angle iron verticle 2.0 m long 3 No 25 mm x 3mm flat iron ring 60 cm dia and 1.55 m welded mess 100 mm x 100 mm size of 3.4 mm thick wire bolted together with 8 mm dia 30 cm long S bolt and nuts incl welding etc and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 300 Each Job
252 19.9 Supply only Farm yard Manure for putting in the plant beds complete all as specified and directed. 745 Cum
253 19.91 Supply only Neem cake for putting in the plant beds complete all as specified and directed. 745 Kg
254 19.92 Supply only DAP for putting in the plant beds complete all as specified and directed. 745 Kg
255 19.93 Supply only Furodong for putting in the plant beds complete all as specified and directed. 745 Kg
256 19.94 Supply only Urea for putting in the plant beds complete all as specified and directed. 745 Kg
257 19.95 Supply only Chloropyriphos emulsion concentration 20% EC comforming to IS 3944 for putting in the plant beds complete all as specified and directed. 300 Ltr
258 19.96 Supply and stacking good earth at site incl royalty and carriage up to with all lead and left complete all as specified and directed. (good earth qtys measured in stacks, will be reduced by 20% for payment) 370 Cum
259 19.97 Solar PV System Supply and installed solar Photo -Voltaic plant for roof top complete of capacity 63.00 KWp without battery backup and on Grid system with (a) Solar PV modules (b) Module mounting system structures (c) Cables and connections (d) Power conditioning unit (PCU), Inverters (e) Protection switch Gears. (f) Weather monitoring system .(g) SCADA System . (h) Earthing and lightniing System. (j) Cabel duct . complete all as specifed and directed / designed . 63000 WP
260 19.98 TREES CUTTING AND DISPOSAL Pruning and cutting of 201 Nos green standing trees as specified in prticular specification and completely disposal frm site complete all as directed and specified. 1 Comlete Job