Supply, Installation, Testing And Commissioning Of Outdoor Type Video Wall With Structure At The Calcutta National Medical College & Hospital [ Job No: Kit / Ow / 204 Of 19-20 ] -1 Sitc Of Direct Lit Led Video Wall ( 3200Mm X 1800Mm ± 5% Display Size Apporx ) With Following Configuration: Nscreen Resolution: W 480 X H 405 Or Higher, 3 In 1 Smd ( Nation Star Gold Wire ) , Brightness: 5500 Cd / M² Or Better, Pixel Per Panel: 120 X 135 Dots, Pixel Pitch: 6.0 ( ± 12% ) Mm Minimum Pixel Density: Minimum 22500 Pixel / Sqm ( ± 12% ) , Cabinet Weight: 24.30Kg / Sqm Or Lower, Module Size: W: 400 Mm X H: 300 Mm, Cabinet Size: W800mm X H900mm X D96mm, Maintenance: Front / Rear, Aspect Ratio: 8:9, Cabinet Area: 0.72 Sqm Or Lower, Recommended Viewing Distance = 6.7 M, Cabinet Material: Profile Aluminium, Environment: Outdoor, Ingress Protection: Ip65 / Ip54, Operating Temperature: 20°C~+50°C / 10~90%Rh, Gap Between Module: Seamless, Horizontal Viewing Angle: 120° Or Higher, Vertical Viewing Angle: 90° Or Higher, Colour Temperature: 2000 – 9300 K Adjustable, Colours: 4.4 Trillion, Brightness Control: Manual / Automatic, Contrast Ratio: 2000:1 Or Higher, Input Power ( Max ) : 700W / Sqm, Input Power ( Typical ) : 234W / Sqm, Driving Method: Constant Current Drive, Video Frame Rate: 50 / 60 Hz, Refresh Rate: 1920 Hz Or Higher, Input Voltage: 100 – 240 Vac, Input Power Frequency: 47-63 Hz, Input Signal : Dvi / Hdmi / Vga / Sdi / Dp / Av / S-Video Etc., Led Life Time : = 100, 000 Hours, Led Wavelength : R:620~630Nm G:520~535Nm B:465~475Nm, Standard Mounting Configuration: Fixed, Data Interconnection: Network Cable ( L=100M ) ; Multi-Mode Fiber ( L=300M ) ; Single Mode Fiber ( L=15Km ) . Interface Signal Input Dvicontrol System Nova Intensity Control Based On Ambient Light / Time - Supported Networking Through Lan / Wan; Including Necessary Hdmi Cable, Dvi With All Other Accessories As Per Site Requirement. The Display Should Be Weatherproof. Nmake: Delta / Nec / Lg / Sony / Panasonic / Samsung / Unilumin / Leyard 2 Monopole ( Flag Type ) Supporting Structure With 15 Ground Clearance, Acp Cladding In Both The Sides & Back As Per The Specification Annexure - 1 3 Media Player ( Windows ) + Electrical Component 4 Cms Software - Server License ( Perpitual ) 5 Cms Software – Client License ( Perpitual ) 6 Sitc Of Layer 2, Poe Enabled, With Pd: Minimum 184.8 Watt ( Should Have Minimum 15.4 Watt Per Port ) , Fully Managed, 1Ru, Ge Switch To Be Operated On 200-240Vac, 50 Hz Supply, With Three Year Software Renewable License Of Oem, Having Minimum Technical Specification: Na ) 12 X 10 / 100 / 1000Base-T Mbps Poe+ Enabled Host Ports ( Minimum ) & 2 X 10 / 100 / 1, 000 Base-X Mbps Ports, ; B ) 2 X 1 / 10Ge Sfp+ ( 1 + 1 Ge Combo Sfp ) Port Including Modular And Field Replaceable Sfp Module Of Same Rating; C ) 51 Mbps Stacking Bandwidth / Backplane Speed ( Minimum ) . D ) Fanless Operation With Operating Temperature Up To 50°C; E ) 512Mb Dram And 240Mb Flash Ram ( Minimum ) .; F ) Software Support With Ipv4 Routing ( 542 Routes ) , Multicast Routing ( Igmp ) Including Necessary Software License; G ) Minimum Switching Capacity Of 336Gbps; H ) Number Of Vlan Supported: 64 ( Minimum ) .; I ) Total Number Of Mac Address: 8, 000 ( Minimum ) ; J ) Minimum Security: User Privilege Management And Password Protection, Dos Attack Defense, Arp Attack Defense, And Icmp Attack Defense, Binding Of The Ip Address, Mac Address, Interface, And Vlan, Port Isolation, Port Security, And Sticky Mac, Mff, Blackhole Mac Address Entries, Limit On The Number Of Learned Mac Addresses, 802.1X Authentication And Limit On The Number Of Users On An Interface, Aaa Authentication, Radius Authentication, Hwtacacs Authentication, And Nac, Ssh V2.0, Hypertext Transfer Protocol Secure ( Https ) , Cpu Defense, Blacklist And Whitelist; Access Security: Dhcp Relay, Dhcp Server, Dhcp Snooping, Dhcp Security; K ) Others: Applicable Standards: Ieee 802.1P: Cos Prioritization , Ieee 802.1Q: Vlan Tagging, Ieee 802.1X: Port Access Control, Ieee 802.3: 10Base-T, Ieee 802.3U: 100Base-T, Ieee 802.3Ab: 1000Base-T, Ieee 802.3Z: 1000Base-X, Ieee 802.3Af: Power Over Ethernet, Ieee 802.3At: Power Over Ethernet Plus, Ieee 802.3X: Pause Frames / Flow Control, Ieee 802.1D: Spanning Tree Protocol, Ieee 802.1S: Multiple Instances Of Spanning Tree Protocol ( Mstp ) , Ieee 802.1W: Rapid Reconfiguration Of Spanning Tree Protocol, Ieee 802.3Ad: Link Aggregation Control Protocol; L ) Regulatory: Rohs, Weee, Iec 61000-4-2:2008, Cispr Class, Ices-003 Class A, Ul, Csa 22.2, Fcc, En 300 386, Ccc, Ices -003, Cb. The Oem Should Have 24X7 Tac Support Center With India Toll Free Number Reflected In Official Website. Nmake: Extreme, Ref Model: X440-G2-12P-1Ge4 Or Equivalent Of Juniper / Cisco 7 Supply Of: Desktop Workstation With The Following Configuration: Nprocessor: Intel Core I7-9700K ( 8 Cores, 8 Threads, 3.60Ghz Base Frequency, 4.90 Ghz Max Turbo Frequency, 12 Mb Cache, 95 W ) Or Higher; Chipset: Intel C236 Or Higher, 2 Dimm Slots Or Higher And Minimum 4 Pcie Series Expansion Slots; ; Ram: Ddr4 16 ( 1X16 ) Gb 2666Mhz With Support For Expansion Upto 64 / 128 Gb; Hard Disk: 1 X 2Tb Sata 7200 Rpm; Integrated Graphics: Uhd / 4K Intel Graphics 630 Or Higher; Dedicate Graphic Card: 4Gb Ddr5 Nvidia Quadro P600 Or Higher; Management: Intel Vpro ( Optional ) ; Operating System: Windows 10 Pro 64Bit Preloaded With Latest Build Along With Recovery Media; Networking Interface: Integrated Gigabit 10 / 100 / 1000; Connectivity: Integrated Dual Band Wi-Fi 802.11 A / B / G / N / Ac & Bluetooth 4.2 Combo Or Higher; Optical Drive: Integrated Rw / Dvd Drive; Display: 27 Inch Or Higher, Full Hd Or Better, Antiglare, Non-Touch, Led-Backlit Monitor; 178° Vertical / 178° Horizontal Display Viewing Angle, Monitor Stand Should Be Height Adjustable; Should Have At Least One Vga, One Display Port, One Hdmi Port And Four Usb Ports; Audio: Integrated Audio Controller With Internal Speaker; Keyboard: Standard Keyboard; Mouse: Optical Scroll Mouse; Usb / Hdmi / Vga Ports: Integrated Hdmi Port: Minimum 3 No, Integrated Vga / Display Port: Minimum 1 No, Integrated Usb Port: Minimum 8 Nos ( Min 4 Nos Of 3.1 Gen-1 ) , Out Of 8 Nos Minimum 4 In Front, 4 In Back And Should Be Easily Accessible; Security: Hardware Based Tpm 2.0, Chassis Intrusion Switch / Intrusion Sensor With Chassis Physical Security Cable Lock Slot; Smps: Minimum 230 W Or Above; Production Unit, Certification And Compliance: Windows 10 Pro Certification For The Quoted Desktop Model, Epeat India For The Quoted Desktop Model, Minimum Energy Star 5.0 & Tco Certification For Both Monitors And Desktop Model, Iso 9001 And 14001 Certified For Oem India Unit; Inclusive Of Mouse Pad, Dust Cover. To Be Installed At Site. Ngem Id: 5116877-47337328299 / 5116877-19904631207 Nmake: Dell / Hp 8 Excavation Of Cable Tranches 900X 300Mm And Refilling The Same After Laying Of Cable With Bricks And Sand And Sundry Materials As Required 9 Supply & Laying Of 32 Mm Gi Pipe With All Accessories. Nmake: Jindal / Bansal / Zenith Birla 10 Sitc Of Multi Tube Double Sheathed Steel Armoured Ofc Cable, 6F, 6T, 50 / 125 Micron, Om3. Nmake: Molex / Legrand / R & M / Commscope / Belden 11 Sitc Of I / O Port Adpater Rj45 / Rj11 With Gi Box And Single Face Cover Plate Etc Nmake: Molex / Legrand / R & M / Commscope / Belden 12 Sitc Of Patch Chord Category 6 4-Pair, F / Utp, Horizontal Cable, 23 Awg Solid Bare Copper Conductors With Rj45 Connector At Both End 2 Mtr Length, Nmake: Molex / Legrand / R & M / Commscope / Belden 13 Sitc Of Wall Mounted Cross Connect Equipments N12u X 600 X 500 Rack - Front Glass Door With Cam Lock - Fan Unit Of 90Cfm / 230 Volt - 1No - 6 Way 5A Pdu, Along With Input Cable - 1No . Hardware Packet Of 20-3 Nos. Nmake: Vertiv / Netrack / Valrack / Apw / Tata 14 Sitc Of Multi Mode Liu, 12F, 1U Drawer Shelf, Fully Loaded With Sc, Om3 Pigtails, Adapters, Splice Trays, Fiber Management Rings And Splice Slvees. Nmake: Molex / Legrand / R & M / Commscope / Belden 15 Sitc Of 10Gb Duplex Multimode 50 / 125 Om3 Lszh Fiber Patch Cable, Sc-Sc / Sc-Lc / Lc-Lc As Per Sites Requirements - 3 Mtr, Nmake: Molex / Legrand / R & M / Commscope / Belden 16 Sitc Of 1G Base Sr Sfp Module Nmake: Cisco / Extreme / Juniper / Brocade 17 Sitc Of Ofc Media Converter N ( Including Splicing Of 6-Core Ofc Om3 If Necessary ) . Nmake : Mrotek / Dlink 18 Sitc Of: 2Kva ( 2.0 / 800 ( Kva / Vah ) ) Line-Interactive Ups With Following Configuration: N2.0Va / 1200 Watt Or Higher Line Interactive Micro Processor Controlled Ups; Input Volt. Range: 140-300V ( Full Load ) ; Nominal Input Freq: 50Hz; Output Volt. Range: 230V + / - 10% ( Batt. Mode ) ; Output Freq. Range :50Hz + / - 1%; Receptacle: 3 X Indian Socket; Internal Batt: 2 X 7 / 9Ah; 90% Batt. Recharge: 4-6Hrs; Cold Start: Require; Operating Temp: 0-40*C; Surge Protection: Inbuilt; Bis Certification Require; Type Test Report; Iso 9001, Iso14001, Oshas18001; Nmake: Delta / Apc / Vertiv / Numeric / Avo, Model: Tower Type. 19 Supply & Laying Of 19 Mm Dia Hdpe Pipe ( Isi Marked ) With All Accessories As Required For The Entire System With All Oem Accessories As Per The Site Requirement. Nmake: Supreme / Oriplast Quality : Isi 20 Sitc Of: 10 Kva 1-Phase Air Colled Out Door Type ( Withtrue Ip-65 / 66 Protection ) Survo Controlled Voltage Stabiliser, High / Low Voltage Cut Out, Single Phasing Prevention & Adjustabletime Delay At The Output; Input Voltage: 120V- 260 / 280V, 50Hz, 1-Ph, Ac, Output Voltage: 220 / 230 / 240 V.50Hz, 1-Ph, Ac; Voltmeters On Each Phase At Input And Voltmeter & Ammeter Indicate Line Voltage Output And Output Current With Help Of Selector Switches. High And Low Voltage Indicators With Visual Alarm. Maximum Tempurature Rise Above Ambient = 90°C; Efficiency At Rated Output ( % ) : > / = 95% Npower Factor: > / =0.95; Complete With Wall / Pole / Floor Mounting Arrangement. Nmake: Numeric / Vanus / Powerone / Fiji / Delta Ngem Id: 5116877-91933469409 / 5116877-73598332177 21 Sitc Of: 35 Sq Mm 3 Core Frls Pvc Insulated Armoured Isi Marked Copper Cable With Gi Medium-Gauge Protection Through Pvc Pipe And 2 X 32 / 42A Mccb ( Or Equivalent Rating ) Proction From Power Supply Main Switch To Servo And Servo To Led Display Panel Respectively Complele With All Necessary Accessories Directed By Engineer In Charge At Site. Nswitch, Sockets & Mcb Make: Legrand / Hager / Siemens / L&T, Wire Make: Polycab / Mescab / Finolex 22 Sitc Of: Earthing With Copper Plate ( 610X610x3mm Size ) Having Weight Of 9.84 Kg And 1 No. 25X5mm Copper Strip ( 3.20 Mt Long ) & 1 No. 6 Sqmm Pvc Insulated Stranded Copper Wire ( 4 Mt Long ) Incl. S & F 15 Mm Dia Gi Pipe ( Isi-Medium ) Protection ( 4 Mt. Long ) To Be Fillied With Bitumen, Partly Under The Ground Level & Partly Above Ground Level To An Average Depth Of 3.65 Mts. Below The Ground Level And Restoring The Surface Duly Rammed Incl. Providing 3.0 Mt Long, 25 Mm Dia Gi Pipe ( Isi-Medium ) For Periodic Treatment, Incl. Providing Masonery Enclosure On The Top Of The Earth Electrode Of Overall Size 86.36X86.36X46cm Deep ( Below Ground Level ) Complete With Cemented Brick Work ( 1:6 ) Of 25 Cm Width, Duly Plastered With Cement Morter ( Inside ) Ci Hinged Inspection Cover Of Size 36.56X35.56Cm With Locking Arrangement, Gi Reducer And Treatment Of Soil By Using Salt & Charcoal Or Coke For Plate Electrode And Necessary Connection With Servo Voltage Stabiliser 23 Supply & Laying Of 1.1 Kv Grade 4 Core X 10 Sq.Mm. Pvc / Cu. Ar. Cable Through In Underground Trench And Necessary Clamping Arrangement To Run Atop The Unipole Structure As Per G.S. ( 10 Mtr For Each Pillar Box ) 24 Supply & Fixing Of Brass Compression Type Cable Gland Suitable For 4 Core X 10 Sq.Mm. Pvc / Cu. Ar. Cable & Finishing The Ends With Dowels Cu. Crimping Socket As Per Gs. ( 2 Sets For Each Pillar Box ) 25 Supply & Drawing Of 1.1 Kv Grade Pvc Insulated 4 X 10 Sq.Mm. Sizes Of Single Core Standard Copper Conductor Wire For Meter Interconnection With Necessary Fixing Arrangement As Required. ( 1.5 Mtr X 4 For Each Pillar Box ) 26 Finishing The Ends Of The 4 X 10 Sq.Mm. Sizes Of Standard Copper Conductor Wires With Dowels Copper Crimping Sockets At Both Sides As Per G.S.