Special Repairs To Bldg No T 67 And T 68 In H Zone Special Repair To Flooring And Wall Of Bldg No Csd_S_14 At Csd Depot Dimapur Provision Of Certain Lbw Revenue And Minor Works Under Age Br_Ii Of Ge 868 Ews, Rangapahar-Nagaland

Military Engineer Services-MES has published Special Repairs To Bldg No T 67 And T 68 In H Zone Special Repair To Flooring And Wall Of Bldg No Csd_S_14 At Csd Depot Dimapur Provision Of Certain Lbw Revenue And Minor Works Under Age Br_Ii Of Ge 868 Ews. Submission Date for this Tender is 18-02-2020. Building Repair Tenders in Rangapahar Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

23444757
Special Repairs To Bldg No T 67 And T 68 In H Zone Special Repair To Flooring And Wall Of Bldg No Csd_S_14 At Csd Depot Dimapur Provision Of Certain Lbw Revenue And Minor Works Under Age Br_Ii Of Ge 868 Ews
Open Tender
Indian
Nagaland
Rangapahar
18-02-2020

Tender Details

Special Repairs To Bldg No T 67 And T 68 In H Zone Special Repair To Flooring And Wall Of Bldg No Csd_S_14 At Csd Depot Dimapur Provision Of Certain Lbw Revenue And Minor Works Under Age Br_Ii Of Ge 868 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 77280.0 /-
Tender Value
INR 38.63 Lakhs /-

BOQ Items

Name of Work : SPECIAL REPAIRS TO BLDG NO T-67 AND T-68 IN 'H' ZONE, SPECIAL REPAIR TO FLOORING AND WALL OF BLDG NO CSD-S-14 AT CSD DEPOT DIMAPUR, PROVN OF CERTAIN LBW, REVENUE AND MINOR WORKS UNDER AGE B/R-II OF GE 868 EWS (JOB NO:- RP/RW/017/19-20, RP/RW/018/19-20, RP/SR(B)/013/19-20, RP/MW/054/19-20, RP/MW/052/19-20, RP/MW/062/19-20, RP/MW/065/19-20, RP/MW/056/19-20, RP/MW/060/19-20, RP/RW/019/19-20, RP/LBW/015/19-20 AND DEPOSIT WORK OF CSD, DIMAPUR)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge 180 Sqm
2 2 Dismantling wall and ceiling boards (fibre pulp insulation etc) or insulation boards, slabs, blankets any thickness, incl cover fillets complete all as specified and directed by Engr-in-Charge 60 Sqm
3 3 Dismantling timber scantlings 40 sqcm and over in section unframed work complete all as specified and directed by Engr-in-Charge 0.6 Cum
4 4 Dismantling boarding any description fixed in any position with nails complete all as specified and directed by Engr-in-Charge 50 Sqm
5 5 Dismantling mild steel or wrought iron work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge 0.2 Qtl
6 6 S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing ( Beam, tee, angle, channel or flat sections) incl distance pieces, cleats etc GDE Fe 410-0-or Fe 310-0 complete all as specified and directed by Engr-in-Charge 20 Kg
7 7 S & F Pre-painted galvatume aluminum zinc coating GI vased corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by Engr-in-Charge 170 Sqm
8 8 S & F Pre-painted galvatume aluminum zinc coating GI vased Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by Engr-in-Charge 10 Sqm
9 9 S/F 2nd class hard wood scantling as in purlins rafters ,& framed work etc clean sawn complete all as specified and directed by Engr-in-Charge. 0.7 Cum
10 10 S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-Painted self embossed, textured designer board E-Board Classic to be fixed GI powder coated grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mm duly suspended with 4mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size etc complete all as specified and directed by Engr-in-Charge 60 Sqm
11 11 M & L 25mm thick second class hard wood boarding , plained one side with butt joints as in eaves boards complete all as specified and directed by Engr-in-Charge 5 Sqm
12 12 S&F 12mm preliminated particle board, interior grade , preliminated both side with decorative choice limination fixed with screws to timber frame work complete all as specified and directed by Engr-in-Charge 5 Sqm
13 13 S&F 12mm Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by Engr-in-Charge 5 Sqm
14 14 S&F12mm thick Veneered decorateive plywood, grade 1 (with BWR resin) with decorate face veneers on one faces; fixed with screws to timber frame work as wall panel complete all as specified and directed by Engr-in-Charge 40 Sqm
15 15 S&F brass continious piano hinges width of flaps 30mm complete all as specified and directed by Engr-in-Charge 5 RM
16 16 Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground level complete all as specified and directed by Engr-in-Charge 29.3 Cum
17 17 Dismantaling floor,hearth or wall tiling including cement mortar bedding (but not backing),removing serviceable tiles to store and rubbbish off the premises complete all as specified and directed by Engr-in-Charge 100 Sqm
18 18 M&L 25 mm thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate) as in level course complete all as specified and directed by Engr-in-Charge 80 Sqm
19 19 M&L for coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engr-in-Charge 20 Sqm
20 20 M&L for non skid coloured joint free tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engr-in-Charge 60 Sqm
21 21 M&L for coloured Glazed ceramic tiles in vertical surfaces of size exceeding 0.11 sqm but not exceeding 0.38 sqm, 7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge 10 Sq.m
22 22 M&L for machine cut Kota stone slab flooring 18 to 20 mm thick as in flooring , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finished complete over screed bed of 15mm thick in CM 1:6 complete all as specified and directed by Engr-in-Charge 241 Sqm
23 23 M&L for machine cut Kota stone slab of 18 to 20mm thick, in riser of steps, skirting, dado etc. over & including 10mm thick rendering (bedding layer) in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finished complete all as specified and directed by Engr-in-Charge 14.5 Sqm
24 24 M&L Chequered cement concrete tiles20cmx20cmx25mm thick, set jointed and pointe in neat cement slurry with grey cement and pigment over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge 10 Sqm
25 25 M&L 75 mm thick cement concrete type C2 1:3:6 (40 mm graded aggregate) as in plinth protection, using extra cement for finishing complete all as specified and directed by Engr-in-Charge 82 Sqm
26 26 M&L cement concrete type C2 1:3:6 (40 mm graded agg) as in surface channels and drains complete all as specified and directed by Engr-in-Charge 0.5 Cum
27 27 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl firms moulds complete all as specified and directed by Engr-in-Charge 50 RM
28 28 M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and othe similar bands, plinth courses, bed plates, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed by Engr-in-Charge 0.6 Cum
29 29 M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in lintel/lintel bend etc complete all as specified and directed by Engr-in-Charge 0.1 Cum
30 30 M&L form work for lintel and RCC/PCC bend in walls etc complete all as specified and directed by Engr-in-Charge 1 Sqm
31 31 Taking down chowkhat or frame not exc 1.5 sqm each (with out taking off shutters from the frame) complete all as specified and directed by Engr-in-Charge 2 Each
32 32 Taking down chowkhat or frame exc 1.5 sqm not exc 4 sqm each (without taking off shutters from the frame) complete all as specified and directed by Engr-in-Charge 2 Each
33 33 Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each complete all as specified and directed by Engr-in-Charge 2 Leaf
34 34 Taking down shutters of any description n.exc 1 Sqm each complete all as specified and directed by Engr-in-Charge 4 Leaf
35 35 M&L 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints complete all as specified and directed by Engr-in-Charge 0.1 Cum
36 36 M&L 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engr-in-Charge 4 Sqm
37 37 M/L 35mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(a) complete all as specified and directed by Engr-in-Charge 2 Sq.m
38 38 M/L 30mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated without sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified and directed by Engr-in-Charge 2 Sq.m
39 39 Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing fixing new ones complete all as specified and directed by Engr-in-Charge 1 Sqm
40 40 S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engr-in-Charge 1 Sqm
41 41 S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engr-in-Charge 1 Sqm
42 42 M & L sheet glass ordinary quality 3mm thick and glazing with oil putty in squares n.exc. .5 sqm each pane complete all as specified and directed by Engr-in-Charge 1 Sqm
43 43 M & L sheet glass ordinary quality 5.5 mm thick and securing in wooden /metal frames glazed with putty/beads in squares exc. .5 sqm each pane complete all as specified and directed by Engr-in-Charge 1 Sqm
44 44 S&F 3mm thick frosted sheet glass, ordinary quality and glazing with oil putting in square n.exc 0.5 sqm in each pane complete all as specified and directed by Engr-in-Charge 1 sqm
45 45 S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engr-in-Charge 1.7 Sqm
46 46 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-Charge 5 RM
47 47 S&F Powder coated of any colour (Thickness or powder coating not less than 50 micron) Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified complete all as specified and directed by Engr-in-Charge 50 Kg
48 48 S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engr-in-Charge 1 Each
49 49 M&L butt hinges medium weight cold rolled mild steel and fixed, 75 mm long size complete all as specified and directed by Engr-in-Charge 6 Each
50 50 M&L butt hinges medium weight cold rolled mild steel and fixed, 100 mm long size complete all as specified and directed by Engr-in-Charge 6 Each
51 51 S/F Aluminium anodised barrel tower bolt of extruded section and fixed 200 mm long complete all as specified and directed by Engr-in-Charge 6 Each
52 52 S&F Aluminium handle cast type anodised 150 mm long complete all as specified and directed by Engr-in-Charge 4 Each
53 53 S&F 125mm size aluminium handles,cast type,anodised all as directed complete all as specified and directed by Engr-in-Charge 4 Each
54 54 S&F aluminium hat & coat hooks solid body 125 mm to 175 mm fixed with brass screw complete all as specified and directed by Engr-in-Charge 2 Each
55 55 S/F Aluminium alloy anodised sliding door bolt with hasp and staple (bolt type fixing clips of sheet cast or extruxded section (250 mm long) complete all as specified and directed by Engr-in-Charge 2 Each
56 56 S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and directed by Engr-in-Charge 2 Each
57 57 Taking down cement plaster on brick walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge 105 Sqm
58 58 Supply only integral water proofing compound complete all as specified and directed by Engr-in-Charge 20 Kg
59 59 Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excl ashalar facing complete all as specified and directed by Engr-in-Charge 1 Cum
60 60 M&L brick work with sub class B bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete all as specified and directed by Engr-in-Charge 1.5 Cum
61 61 Brickwork but except bricks with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed by Engr-in-Charge 0.2 Cum
62 62 M&L brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engr-in-Charge 51 Sqm
63 63 Brickwork but except bricks with sub class B bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engr-in-Charge 10 Sqm
64 64 M & L rendering 15mm thick in cement mortar 1:4 mixed with water proofing compound @ 3% by wt of cement finished fair faces of brick/concrete surfaces even and fair without using extra cement complete all as specified and directed by Engr-in-Charge. \nNote : WPC will be measured and paid separately. 50 Sq.m
65 65 M & L rendering 15mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. 50 Sq.m
66 66 Demolition of reed lathing single or double inclduing batten and plaster or chicken wire lathing complete all as specified and directed by Engr-in-Charge 60 Sqm
67 67 M&L 18 mm thick plastering in CM 1:4 on one side of lathing in two separate layers even and smooth without using extra cement incl WPC complete all as specified and directed by Engr-in-Charge \nNote : WPC shall be measured and paid separately 60 Sqm
68 68 M&L 12 mm thick plastering in CM 1:6 the other side of lathing finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge 60 Sqm
69 69 M&L GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and directed by Engr-in-Charge 60 Sqm
70 70 Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works complete all as specified and directed by Engr-in-Charge 0.1 Cum
71 71 M&L for reinforced cement concrete (nominal mix) 1:2 :4 type B1 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like complete all as specified and directed by Engr-in-Charge\nNote :- Reinforcement & formwork shall be measured and paid for separately. 0.1 Cum
72 72 S&F TMT MS bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and directed by Engr-in-Charge 20 Kg
73 73 All same as per item No 72 above but 5mm dia and over and including 10mm dia in stirrups spacers and binders complete all as specified and directed by Engr-in-Charge 15 Kgs
74 74 M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete. complete all as specified and directed by Engr-in-Charge 1 Sqm
75 75 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar complete all as specified and directed by Engr-in-Charge 0.3 Ten Sqm
76 76 M&L for 20 mm thick Granite (of any tpe) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like in cement mortar (1:4) including pointing in white cment (1:2) using marble dust with admixture of pigment to match with shade of granite. & including 15mm thick screed bed (bedding layer) in CM 1:4, all as specified & directed by Engineer-in-charge. 1 Sqm
77 77 M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge 30 Sqm
78 78 M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge 20 Sqm
79 79 M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge 15 Sqm
80 80 M&L for preparation of new untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge 15 Sqm
81 81 M&L for preparation of new untreated steel surfaces of any description not otherwise described n exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge 11 10 RM
82 82 M&L for preparation of old painted surfaces of any description not otherwise described n exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge 10 10 RM
83 83 M/L for 2 mm thick Birla white putty/JK white wall care putty on walls complete all as specified and directed by Engr-in-Charge 10 Sqm
84 84 M&L for preparation of old decorated surfaces of walls (plastered) by brooming down with steel wire brushing and applying one coat of white wash on wall complete all as specified and directed by Engr-in-Charge 5 Sqm
85 85 M & L for preparation of new plastered surfaces of wall and applying three coat of white wash complete all as specified and directed by Engr-in-Charge 12 Sqm
86 86 M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper of approved shade/tint over a coat of primer on walls complete all as specified and directed by Engr-in-Charge 172.5 Sqm
87 87 M&L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper of approved shade/tint complete all as specified and directed by Engr-in-Charge 25 Sqm
88 88 M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls complete all as specified and directed by Engr-in-Charge 172.5 Sqm
89 89 M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint of approved shade on walls complete all as specified and directed by Engr-in-Charge 45 Sqm
90 90 S&F in repairs Harrison rails, mild steel , chromium plated with fixing brackets, stops, rollers ets complete all as specified and directed by Engr-in-Charge 25 RM
91 91 S&F Aluminium (die cast) body door closer hydrulically regulated, designation No 2, universal type suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kg and fixed complete all as specified and directed by Engr-in-Charge 1 Each
92 92 Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 15 mm bore GI tubing complete all as specified and directed by Engr-in-Charge 10 RM
93 93 Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 20 mm bore GI tubing complete all as specified and directed by Engr-in-Charge 5 RM
94 94 Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling as directed, for 15mm bore GI tubing complete all as specified and directed by Engr-in-Charge 5 RM
95 95 Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling as directed, for 20mm bore GI tubing complete all as specified and directed by Engr-in-Charge 5 RM
96 96 M&L cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth complete all as specified and directed by Engr-in-Charge 5 RM
97 97 S&F tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 15 mm bore complete all as specified and directed by Engr-in-Charge 10 RM
98 98 S&F tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore complete all as specified and directed by Engr-in-Charge 10 RM
99 99 Supply and fixed in repair vitreous china wash hand basin including brackets, white size 550 x 400 mm incl cutting cutting for and pinning in ends of brackets. Including Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed by Engr-in-Charge 1 Each
100 100 S & F in repairs pillar tap of 15 mm dia , chromium plated fancy type , screwed for iron pipes complete all as specified and directed by Engr-in-Charge 1 Each
101 101 S&F CP toilet paper holder as approved by GE complete all as specified and directed by Engr-in-Charge 1 Each
102 102 S&F in repairs vitreous china water closet Padestal pattern (white) excluding fixing bolts, flushing cistern and flush pipe and including EWC Sheet cover complete all as specified and directed by Engr-in-Charge 1 Each
103 103 Supply & fixing in repair vitreous china squatting pan (Orissa pattern) water closet (white) size 580x440mm with integral foot rests (excluding flushing cistern and flush pipe) complete including connection to trap and flushing pipe antisyphonage pipe etc including provision of PCC (1:7:12) type F2 in filling complete all as specified and directed by Engr-in-Charge 1 Each
104 104 S&F in repair PVC flushing cistern syphonic action type, 10 liters capacity, low level white with inlet ball valve, float and handle including bracket including PVC flush pipe, 32mm dia as fixed in repairscomplete all as specified and directed by Engr-in-Charge\nMake : Hindware (Sleek)/Commander (Slim)/Parryware 1 Each
105 105 S&F in repairs for 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-Charge. 1 Each
106 106 S&F in repairs for 15mm dia of pipe stop valves,fancy type and chromium plated (concealed type long shank) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixed complete all as specified and directed by Engr-in-Charge 1 Each
107 107 S&F in repairs for 15mm dia of pipe Angle valves,fancy type and chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixed complete all as specified and directed by Engr-in-Charge 1 Each
108 108 Supply and fixing 20 mm dia gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge 1 Each
109 109 S&F in repairs PVC connection 15mm dia and 45cm long with two Nos of brass checknuts and washers complete all as specified and directed by Engr-in-Charge 1 Each
110 110 S& F in repair swivel shower of CP any colour for fixing with 15 mm pipe (min weight 40 gms) incl shower arms 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (min weight 40 gms) complete all as specified and directed by Engr-in-Charge 1 Each
111 111 Supply and fixing of soap-dish chromium plated complete all as specified and directed by Engr-in-Charge 1 Each
112 112 S&F in repairs 600mm long tubular tower rail brass chromium plated 20mm dia, D type 60cm long fixed with two plugs (Gutties) of 2nd class hard wood embeded in cement mortor 1:3 with MS screws complete all as specified and directed by Engr-in-Charge 1 Each
113 113 S& F in repairs PVC mounted 5mm thick bevelled edge looking mirror 550 x 400mm including taking down old fixed complete all as specified and directed by Engr-in-Charge 1 Each
114 114 S&F PVC Shelves of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105 gms) complete all as specified and directed by Engr-in-Charge 1 Each
115 115 S&F 0.71 mm thick plain aluminium sheeting , alloy 31000 H4 in ridges, hips , valley gutter , drip and straight flashing complete all as specified and directed by Engr-in-Charge 1 Sqm
116 116 Solar control film 25 micron relfective type complete all as specified and directed by Engr-in-Charge 1 Sqm
117 117 Taking down and refixing the door in same opening after easing & adjusting of shutters of any description exc 1 sqm and n exc 2 sqm each, without taking down complete all as specified and directed by Engr-in-Charge 1 Per leaf
118 118 M&L for anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed by Engr-in-Charge 40 RM
119 119 M&L for anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engr-in-Charge 40 Sqm
120 120 M&L for anti-termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed by Engr-in-Charge 30 RM
121 121 M&L PCC 1:4:8 type D2 (40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge 4.5 Cum
122 122 Formwork fair finished surfaces of concrete to flat sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engr-in-Charge 1.5 Sqm
123 123 M&L reinforced cement concrete 1:2:4 B1(20mm graded aggregate ) in beams, cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed by Engr-in-Charge 0.052 Cum
124 124 Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging using Fe-410-S; also fastening and fixing complete all as specified and directed by Engr-in-Charge 20 Kg
125 125 Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engr-in-Charge 5 Kg
126 126 S&F Sheet glass assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 600 mm long complete all as specified and directed by Engr-in-Charge 1 Each
127 127 S&F steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed by Engr-in-Charge 1 Sqm
128 128 Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engr-in-Charge 0.1 Cum
129 129 Precast RCC (1:2:4) type B-1 in manhole/soack well/septic tanks slabs/covers etc including necessary form work complete set in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge 0.1 Cum
130 130 Material and labour for 75 mm thick PCC 1:4:8 type D2 using 40 mm grded stone aggregate as in sub base complete all as specified and directed by Engr-in-Charge 240 Sqm
131 131 Material and labour for 25mm thick plain cement concrete 1:2:4 Type - B2 ( using 20mm graded stone aggragate) finished rough to receive top layer complete all as specified and directed by Engr-in-Charge 240 Sqm
132 132 M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:6 finished even and smooth withot using extra cement complete all as specified and directed by Engr-in-Charge 22.5 Sqm
133 133 M&L rendering 15mm thick on other than fair faces of brick work or concrete surfaces with CM (1:4)finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge 24.5 Sqm
134 134 M&L complete removal of existing treatment from wall preparation of surfaces of wall and applying one coat of oil bound distember with wall care putty complete all as specified and directed by Engr-in-Charge 40 Sqm
135 135 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft and loose soil complete all as specified and directed by Engr-in-Charge 40 Sqm
136 136 Excavation in post holes (or similar holes) each n. exc 0.50 m and getting out ,in soft/disintegrated rock complete all as specified and directed by Engr-in-Charge 17 Each
137 137 S&F steel work in tubular trusses including (purlins and rafters) special shaped washers etc complete using ERW or induction butt welded tubes complete all as specified and directed by Engr-in-Charge 1190 Kg
138 138 Removing excavated soil & material n exc, 50m and deposition where directed at a level n exc. 1.5m above the starting point complete all as specified and directed by Engr-in-Charge 5.5 Cum
139 139 M&L Machine pressed precast concrete interlocking paver block any shape and size confering to IS 15658-2006 of 60 mm thickness M-35 grade fixed with grey cement and no pigment complete all as specified and directed by Engr-in-Charge 40 Sqm
140 140 M&L sand cusion for interlocking tiles complete all as specified and directed by Engr-in-Charge 1 Cum
141 141 Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/ buzzer, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good to the disturbed surfaces of walls, ceiling, floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and directed by Engr-in-Charge. 121 Point
142 142 M & L for wiring of fan point controlled by one switch using 1.5 Sq mm copper conductor FRLSH cables (multistranded) in and including PVC casing and capping and PVC board with all fitting and fixing materials for fixing of switches and sockets including supplying and laying PVC insulated unsheathed 1100 volts grade copper conductor 1.5 Sq mm earth wire stranded and connected to earth dolly complete all as specified and directed by Engr-in-Charge.\nMake: Havells/Finolex/RR Kabel 133 Point
143 143 One 3 pin socket outlet 5 Amps on the same board with other switches. 7 Point
144 144 One 3 pin socket outlet 5 Amps on the Independent board. 19 Point
145 145 M&L for Point wiring using 2.5 Sqmm for one 5 pin 15 Amps socket outlet on independent board incl multistranded insulated copper earth continuity conductor of size 1.5 Sqmm and fixing materials green colour and connecting to light fittings etc complete all as specified and directed by Engr-in-Charge. 25 Point
146 146 M & L for switch piano flush type 5 amps SP one way 230 volts complete all as specified and directed by Engr-in-Charge.\nMake: Anchor/Plaza/SSK 259 Each
147 147 M&L ceiling rose three terminals/PVC/polycarbonate, isolated body on PVC board complete all as specified and directed by Engr-in-Charge.\nMake: Anchor/Plaza/SSK 194 Each
148 148 M&L bell push , flush type ,5 Amps complete all as specified and directed by Engr-in-Charge. 2 Each
149 149 M&L for Electric Bell, AC 230 volts, single pole complete all as specified and directed by Engr-in-Charge. 2 Each
150 150 S & F stepped type electronic fan regulator 240 Volt, flush type on the existing phenolic laminated sheet complete all as specified and directed by Engr-in-Charge.\nMake: Anchor/Plaza/SSK 52 Each
151 151 S&F Ceiling fan 1200 mm sweep complete single phase 240 volts without regulator but with fan hook of suitable size, including taking down old unserviceable fan & removing to MES store complete all as specified and directed by Engr-in-Charge.\nMake : Havells or equivalent in VGard, bajaj , 42 Each
152 152 M&L for 25 mm dia light grade GI tubing for hanging the ceiling fan including joint to another existing angle frame complete all as specified and directed by Engr-in-Charge. 42 RM
153 153 M&L for 15 mm dia light grade GI tubing for hanging (downrod) the ceiling fan including drilling,holes GI tube complete all as specified and directed by Engr-in-Charge. 88.5 RM
154 154 M&L for 20 mm dia light grade GI water tubing for laid in floors or fixed in wall with GI fittings complete all as specified and directed by Engr-in-Charge. 64 RM
155 155 M&L for fan hook mad out of MS flat 50x6mm suitable to fix at truss complete as per sit requirement complete all as specified and directed by Engr-in-Charge. 45 Each
156 156 S & F for Switch socket combination 16A, 5 in 1, 3 pin, flush type universal complete all as specified and directed by Engr-in-Charge. 25 Each
157 157 S & F for Switch socket combination 5A, 5 in 1, 3 pin, flush type universal complete all as specified and directed by Engr-in-Charge. 36 Each
158 158 M&L for MCB Distribution board double door type SPN 6 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and suitable for fixing MCBs of various rating capacity complete all as specified and directed by Engr-in-Charge. 1 Each
159 159 S&F MCB DB, single door SPN 2 way 240 volts without bus bar , fixed on PVC board complete all as directed at site complete all as specified and directed by Engr-in-Charge. 7 Each
160 160 S & F MCB SPN 32 Amps 240 V complete all as specified and directed by Engr-in-Charge.\nMake : Havells 8 Each
161 161 M&L for MCB SP 5-32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and directed by Engr-in-Charge. 16 Each
162 162 M&L for 20W LED, 4', Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting including taking down old unsv light fitting complete all as specified and directed by Engr-in-Charge. 11 Each
163 163 M&L for 10W LED, 2', Wall mounted polycarbonate batten internally pre-wired with electronic driver and polycarbonate diffuser and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and directed by Engr-in-Charge.\nMake : Havells Cat No LHEXBQP5IN1W009 or equivalent in Bajaj/Philips. 3 Each
164 164 M&L for Lamp holder , PVC/ Polycarbonate type with PVC round/square block incl 9 watt LED lamp suitable for lamp holder fittings including taking down old unsv holder fitting complete all as specified and directed by Engr-in-Charge. 18 Each
165 165 M&L for LED 1x20W Security light fitting, drawn through including GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling holes as required and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting including taking down old unsv light fitting complete all as specified and directed by Engr-in-Charge. 7 Each
166 166 Taking down Ceiling fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearing, painting of fans complete with superior quality synthetic enamel paint by spraying including filling cavaties with filler, after cleaning all dust, reassembling the fan and blades, hanging/ fixing the fan in its original position and testing on completion complete all as specified and directed by Engr-in-Charge. 10 Each
167 167 Taking down Exhaust fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearing, painting of fans complete with superior quality synthetic enamel paint by spraying including filling cavaties with filler, after cleaning all dust, reassembling the exhaust fan and blades, fixing the exhaust fan in its original position and testing on completion complete all as specified and directed by Engr-in-Charge. 2 Each
168 168 M&L for PVC rectangular block for mounting DBs etc of size 350x300x50 mm deep with 3 mm thick plastic plastic laminated sheet cover complete all as specified and directed by Engr-in-Charge. 4 Each
169 169 S&F Electric storage water heater of 25 Ltr capacity complete single phase 240 Volts complete all as specified and directed by Engr-in-Charge.\nMake: Havells monza/Bajaj 7 Each
170 170 M & L for sub main wiring with 2 single core 4 Sqmm copper conductor (Multistranded) including PVC surface casing capping in roof/wall/floors with all fittings and fixtures including 2.5 Sqmm green colour copper conductor as earth continuity complete all as specified and directed by Engr-in-Charge. 185 RM
171 171 S&F 15mm bore stop cock, cast copper alloy fancy type, chromium plated , screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge. 15 Each
172 172 S&F 20mm bore stop cock, cast copper alloy fancy type, chromium plated , screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge. 8 Each
173 173 S&F 15mm bore bib tap fancy type chromium plated with long shank complete all as specified and directed by Engr-in-Charge. 15 Each
174 174 S&F Brass CP Mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engr-in-Charge. 7 Each
175 175 S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed by Engr-in-Charge. 18 Each
176 176 S&F 1100 volts grade heavy duty cables PVC insulated aluminium conductor served with inner sheathed wirh PVC tape and overrall PVC sheathed in service connection support and by insulation hanger not more that 1 mtr apart include 4mm suspension wire one twon core cable flat or circular 10 Sqmm 2 Core standard indl taking down old unsv one complete all as specified and directed by Engr-in-Charge.\nMake; Havells/Finolex/RR Kabel. 249 RM
177 177 M & L for GI swaged and welded steel tubularpole 9 meter long 410 SP-31 conforming to IS 2713-1980 complete with cast iron base plate, finial taper plug, nuts and screws etc. complete all as specified and directed. (Earth work and concrete foudation shall be measured and paid separately under relevant items of Sch 'A') complete all as specified and directed by Engr-in-Charge.\nMake: Calcutta poles/Bansal poles/Nezone tubes Ltd. 21 Each
178 178 S & F energy saving environmental friendly die-cast aluminium IP-66 security lights of capacity 48 Watts 5700K with high power LEDs suitable for single phase 50 Hz AC electric supply complete all as specified and directed by Engr-in-Charge.\nMake: Havells/CG/Bajaj 18 Each
179 179 S & F energy saving environmental friendly die-cast aluminium IP-66 security lights of capacity 70Watts 5700K with high power LEDs suitable for single phase 50 Hz AC electric supply complete all as specified and directed by Engr-in-Charge.\nMake: Havells/CG/Bajaj 18 Each
180 180 M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm, 2 core complete all as specified and directed by Engr-in-Charge.\nNOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. 90 RM
181 181 M& L for PVC insulated electric cable twin core 2.5 sqmm flat/round ISI marked for connection from pole to junction boxes to the light fitting complete all as specified and directed by Engr-in-Charge.\nMake:Richa/Havells/Finolex 315 RM
182 182 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified and directed by Engr-in-Charge. 179.77 Cum
183 183 Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and directed by Engr-in-Charge. 52.14 Cum
184 184 Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and directed by Engr-in-Charge. 127.63 Cum
185 185 M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken complete all as specified and directed by Engr-in-Charge. 65.16 Cum
186 186 M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and directed by Engr-in-Charge. 8390 Each
187 187 M&L for PCC 1:2:4, type B-2 (using 20 mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed by Engr-in-Charge. 1.61 Cum
188 188 M&L for PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete including necessary use & waste of form work complete all as specified and directed by Engr-in-Charge. 12.35 Cum
189 189 M&L for replacement of HDPE pipes fixed to wall ceiling or floor of 25 mm bore complete all as specified and directed by Engr-in-Charge. 135 Per RM
190 190 M&L for PVC pole junction boxes with inbuilt aluminuim bus bar (02 Nos) of suitable size fitted over bus bar insulator and fixing to pole complete all as specified and directed by Engr-in-Charge.\nMake :Sintex/Hensel/C&S 21 Each
191 191 Dismantling cross arms of MS channel or angels sections flats, nuts, bolts washers etc and removing the old materials from the site(s) complete all as specified and directed by Engr-in-Charge. 0.25 Qtl
192 192 Dismantling of old ACSR conductors or disturbed span including line spacer/separator and keeping serviceable materials in safe custody for re-use and unserviceable materials removing from the site (s) complete all as specified and directed by Engr-in-Charge. 1 Qtl
193 193 Taking down LT UG cable/ service connection of any size and M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm,2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items complete all as specified and directed by Engr-in-Charge. 60 RM
194 194 M & L for LT UG cable/ service connection of any size and M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm,2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items complete all as specified and directed by Engr-in-Charge. 60 RM
195 195 All as per item No 194.00 here in before size 25 Sqmm 2 core complete all as specified and directed by Engr-in-Charge. 450 RM
196 196 All as per item No 194.00 here in before size 25 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. 75 RM
197 197 Supply & laying tubes ' light grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking down corroded GI tubing complete all as specified and directed by Engr-in-Charge. 66 RM
198 198 Material & labour for road cutting/ digging of existing Hard surface of cement concreet/Bituminous road of size not less than 45 cm in width and 60 cm deep for laying of GI/CI pipe & making good to the disturbed surfaces by providing PCC or same material after laying of pipe line and returning filling of soil complete all as specified and directed by Engr-in-Charge. 4 Per RM
199 199 M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and directed by Engr-in-Charge.\nNOTE:- (i) The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1, CI cover 10 mm thick, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (iii) Test points shall be made of GI strip 32x6 mm bridge type mounted on insulators, where ever applicable\n 9 Each Set
200 200 Supply and fixing as in replacement 32mm bore street light bracket made of light grade GI pipe of 1.5m long including two coat of aluminium paint over one coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge.\nMake: Jindal 25 Each
201 201 Supply, install, test and commissioning of factory made powder coated (CPRI approved) Outdoor type, dust and vermine proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40mmx 40xx6mm powder coated over one coat of red oxice premium suitabily granted in PCC using 20mm grade stone aggregate (size 1x1x0.05 mtr) including bus bar, internal wiring with PVC insulated single core cable of copper conductor of suitable size duly numbered with tiles for circuit with double door circuit cubical type locking arrangements and slanted roof the size the panel board shall be suitable for housing the under mentioned accessories given here in under complete all as specified and directed by Engr-in-Charge.\nINCOMING : (a)MCCB 63 Amps,3 pole, 230 Volt 16 KA- 01 Nos (Make : Legrand/Schenider /L&T) \n(b) 03 Nos aluminium strips of rating 1.5 times current carrying capacity of incoming MCCB \n (c) Digital voltmeter with inbuilt selector switch \n (d) Digital Ammeter 0 to 100 Amps (e) LED Indicator lamp LED type (RYB) (03 Nos) set-01 \nOUTGOING : (a) MCB 32Amps, C, Curved double pole, 10 KA- 02 Nos (Make : Legrand/Schenider /L&T) \n(b) Astronomical digital time switches single phase with suitable contactor and relays (Make : Legrand/Schenider /L&T) \n 1 Each
202 202 M&L in replacement for decorative wall mounted light fitting made up of polycarbonate including 9 watt LED lamp with B-22 base including taking down old unsv light fitting complete all as specified and directed by Engr-in-Charge.\nMake: Havells/Bajaj/Surya 2 Each
203 203 M& L for 42 watt LED, 2'x2' recess mounte ceiling light fitting extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic drive etc. with all accessories internally pre wired complete all as specified and directed by Engr-in-Charge.\nMake: CG cat No LCTLRN-36-FO-CDL or equivalent in Bajaj/Phipips. 14 Each
204 204 M&L for rubber bush with clamping set, comprising GI bolt, nut and split pin complete all as specified and directed by Engr-in-Charge. 8 Each
205 205 M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder coated, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and directed by Engr-in-Charge.\nMake:- Legrand Cat No 607711 or equivalent in ABB/Siemens 2 Each
206 206 M&L for MCB SPN, 63 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down complete all as specified and directed by Engr-in-Charge.\nMake: Legrand Cat No 408636 or equivalent in ABB/Siemens. 2 Each
207 207 M&L for MCB SP, 5 to 32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and directed by Engr-in-Charge.\nMake:- Legrand Cat No 408587-95 or equivalent in ABB/Siemens 12 Each
208 208 Taking down LT UG cable/service connection of any size and M&L for laying of LT UG cable , XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 4 core complete all as specified and directed by Engr-in-Charge.\nNOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. \nMake: Havells/Polycab/Phinolex 50 RM
209 209 M&L for repair to Fresh air ventilation fan metal body 300 mm sweep fixed with wall incl replacement of unsv loovers complete all as specified and directed by Engr-in-Charge.\nMake: Havells/Usha/PSP. 4 Each
210 210 M&L for repaired of metal clad AC socket point Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engr-in-Charge.\nMake Havells/HPL. 2 Each
211 211 M&L for 10 watt LED map focus light mounted with polycarbonate housing/ batten complete all as specified and directed by Engr-in-Charge.\nMake Havells or equivalent in Bajaj/Philips 4 Each
212 212 M&L for 10 watt LED hanging light for working table hanging from ceiling/roof with thread and plastic spring with polycarbonate housing complete all as specified and directed by Engr-in-Charge. 1 Each
213 213 M&L for boring under existing road/cement concret/butuminous road of size not less than 50mm for laying of GI/CI pipe & makng good to the disturbed surfaces by providing PCC or same material after laying of pipe line and returning filling of sloil complete all as specified and directed by Engr-in-Charge. 10 Per RM