Repair , Renovation Of Room No 315 And 316 And Providing Partition In Room No 316 On Admin Block Of Kashmere Gate Campus Of Ambedkar University Delhi , Delhi - 110006, Ambedkar University Delhi, Lothian Road, Delhi-Delhi

Ambedkar University Delhi has published Repair , Renovation Of Room No 315 And 316 And Providing Partition In Room No 316 On Admin Block Of Kashmere Gate Campus Of Ambedkar University Delhi , Delhi - 110006. Submission Date for this Tender is 27-01-2020. Building Repair Tenders in Ambedkar University Delhi, Lothian Road, Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

23303991
Repair , Renovation Of Room No 315 And 316 And Providing Partition In Room No 316 On Admin Block Of Kashmere Gate Campus Of Ambedkar University Delhi , Delhi - 110006
Open Tender
Indian
Delhi
Ambedkar University Delhi, Lothian Road, Delhi
27-01-2020

Tender Details

Repair , Renovation Of Room No 315 And 316 And Providing Partition In Room No 316 On Admin Block Of Kashmere Gate Campus Of Ambedkar University Delhi , Delhi - 110006

Key Value

Document Fees
INR 590 /-
EMD
INR 24100.0 /-
Tender Value
INR 12 Lakhs /-

BOQ Items

Name of Work: Repair,Renovation and providing partition in room No.316 in Admin block at Ambedkar University Delhi, Kashmere Gate Campus.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Discription BI01010001010000000000000515BI0100001112
2 1.01 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) 142.92 Kg
3 1.02 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber /neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) 17.62 Kg
4 1.03 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides 6.28 Sqm
5 1.04 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.00 mm thickness 12.082 Sqm
6 1.05 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 3 Each
7 1.06 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 100x63x4 mm 3 Each
8 1.07 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm 4 Each
9 1.08 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper 2 Each
10 1.09 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below 4 Each
11 1.1 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. Metres 1 Each
12 1.11 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x75x3.50 mm 6 Each
13 1.12 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm 6 Each
14 1.13 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 51.196 Sqm
15 1.14 CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) 51.196 Sqm
16 1.15 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.\n 207.89 Sqm
17 1.16 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.\n 246.03 Sqm
18 1.17 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre\n 246.03 Sqm
19 1.18 Distempering with 1st quality acrylic distemper, having VOC (VolatileOrganic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required,to achieve even shade and colour. Two coats 246.03 Sqm
20 1.19 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 49.4 Sqm
21 1.2 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 29.776 Sqm
22 1.21 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 0.558 Cum
23 1.22 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete 4.718 Sqm
24 1.23 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1 Each
25 1.24 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 1 Each
26 1.25 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia 1 Each
27 1.26 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 1 Each
28 1.27 Providing and fixing toilet paper holder : C.P. Brass 1 Each
29 1.28 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 15 mm dia nominal bore 12 Meter
30 1.29 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 20 mm dia nominal bore 8 Meter
31 1.3 Providing and fixing uplasticised PVC connection pipe with brass unions : 15 mm nominal bore with 45 cm length 3 Each
32 1.31 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 3 Each
33 1.32 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge 15 mm to 40 mm nominal bore 14 Meter
34 1.33 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm 2 Each
35 1.34 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 4.218 Sqm
36 1.35 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level cement mortar 1:4 (1 cement : 4 coarse sand 1.41 Sqm
37 1.36 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS8225:1987, Light reflectance of 85%(minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e.50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles. 34.85 Sqm
38 1.37 Providing and fixing plain lining with necessary screws/nuts & bolts/nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-incharge (Frame work shall be paid for separately). 12mm thick commercial ply conforming to IS : 1328 BWR type 7.23 Sqm
39 1.38 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved byEngineer-in-charge, beyond 50 m initial lead, for all leads including all lifts up to 10 km 5 Cum
40 1.39 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 3.54 Sqm
41 1.4 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 3.54 Sqm
42 1.41 Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 7.07 Sqm
43 1.42 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window 0.09 Sqm
44 1.43 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square 2.52 Sqm
45 1.44 Providing and fixing Ist quality rectified ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 26.058 Sqm
46 1.45 Providing and fixing two in one C.P. brass bib cock of approved quality as per direction. 2 Each
47 1.46 Dismanting of existing IWC with cistern with all connection including connection pipes, angle wall etc. 2 Each
48 1.47 Providing and fixing dead lock in aluminium door of approved quality as per direction. 1 Each
49 2 Electrical Work
50 2.01 Wiring for light Point/fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/reccessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc. as required Group C 18 Point
51 2.02 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(Make BEC, AKG, Precision) 25mm 70 Meter
52 2.03 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(Make BEC, AKG, Precision) 32mm 46 Meter
53 2.04 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (Make Havels/polycab/finolex) 3 x 2.5 Sq mm 122 Meter
54 2.05 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (Make Havels/polycab/finolex) 3 x 4 Sq mm 68 Meter
55 2.06 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (Make Havels/polycab/finolex) 4 x 6 Sqmm 60 Meter
56 2.07 Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make Legrend- Myrius/Schnider-Zencelo/MK-Citric/Crabtree-Murano) 1 or 2 module (75mm x 75mm) 15 Each
57 2.08 Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make Legrend- Myrius/Schnider-Zencelo/MK-Citric/Crabtree-Murano) 6 module (200mm x 125 mm) 20 Each
58 2.09 Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make Legrend- Myrius/Schnider-Zencelo/MK-Citric/Crabtree-Murano) 12 module (200mm x 150mm) 3 Each
59 2.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..(Make Legrend- Myrius/Schnider-Zencelo/MK-Citric/Crabtree-Murano) 5/6 A Switch 64 Each
60 2.11 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..(Make Legrend- Myrius/Schnider-Zencelo/MK-Citric/Crabtree-Murano) 15/16 A Switch 20 Each
61 2.12 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..(Make Legrend- Myrius/Schnider-Zencelo/MK-Citric/Crabtree-Murano) 3 Pin 5/6A Socket outlet 42 Each
62 2.13 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..(Make Legrend- Myrius/Schnider-Zencelo/MK-Citric/Crabtree-Murano) 6 Pin 15/16A Socket Outlet 20 Each
63 2.14 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(make /systimax/panduit/ Legrend, Belden) 1 Run of Cable 240 Meter
64 2.15 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 6 Each
65 2.16 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB)(make : LnT, Schinider, Legrand) 4 way ( 4 + 12), Double door. 2 Each
66 2.17 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(make : LnT, Schinider, Legrand) Single Pole 24 Each
67 2.18 Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(make : LnT, Schinider, Legrand) 63A 2 Each
68 2.19 Supply and installation following sizes of perforated painted with powder coating M.S. cable tray with perforation not more than 17.5%, in convinenet sections, joined with connectors, suspended from the ceiling with M.S. Suspenders including bolts and nuts, painting suspenders etc. as required. 150mm width x 50 mm depth x 1.6 mm thick. 12 Meter
69 2.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required 50 Meter
70 2.21 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 1 Each
71 2.22 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. 2 Set
72 2.23 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 140 Meter
73 2.24 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 60 Meter
74 2.25 Supplying and fixing 24 hour timer, 230 V and LCD display for Air Conditioner for cyclic operation of two Air conditioners for 1 hour to maximum 12 hours as required. 1 Each
75 2.26 Supplying and fixing of CAT 6 information outlet (I/O) for data, voice rack end complete with feruling and end termination as required.(Make:-(Belden/Legrand-Myrius/MK/Schnider/Crabtree) 15 Each
76 2.27 Supplying, Installation, commissioning & testing of ceiling fan 1200 mm, BEE 5 Star rated without regulator including wiring the down rod with 1.5 sqmm PVC insulated copper wire single core cable complete as reqd. (Crompton Greaves HS Plus 48-inch 53-Watt Power Saver Ceiling Fan (White) or equivalent make Crompton Greaves, Bajaj, Havells) 6 Each
77 2.28 Supplying, Installation, Testing and Commisioning of recessed Mounted ultraslim LED fixture flat panel 2' x 2' made of extruded aluminium frame with high efficient LEDs & glare free opal diffuser min 36 watt complete in false ceiling with driver (constant current and constant voltage) complete in every way as required. (Halonix CAT Ref. No. HLFPU22-02-36-WW or its equivalent) 8 Each
78 2.29 Supplying, Installation, Testing and Commisioning of recessed mounted circular LED downlight fixture, min 15 watt in false ceiling complete with driver (constant current and constant voltage) complete in every way as required. (Philips Part no. 919215850698 or approved equivalent) 12 Each
79 2.3 Removing, Relocation and Installation of existing High Wall Split type air conditioner unit upto 2 TR capacity, including gas charging and all neesery labours, cutting an fixing refrigerent pipes etc. complete as per direction. (The refrigerent pipe shall be measured and paid seperately). 4 Each
80 2.31 Supply & fixing of extra copper referigent piping of 5/8" and 1/4" with 9 mm thick nitrile rubber insulation and 3 x 2.5 sqmm Cu cable.(over and above 3m standard length included in AC item) 88 Meter
81 2.32 Supply and fixing PVC drain pipe of size 25mm along with all the accessories from indoor unit to the nearest location as required. 68 Meter
82 2.33 Supply, installation, Testing and Commissioning of armoured 6 core multimode OFC cable for inter floor switch connectivity with fire retardent propeties in compliance to relevant IEC standards complete etc. As required. (Approved Makes :- Belden/ Panduit/ Siemon/ Molex/ System-x/ Tyco/Schnider. 15 Meter
83 2.34 Supply, installation, Testing and Commissioning of 6 port loaded LIU with adapter plates, pigtel cables for connection complete etc as required. (Approved Makes :- Belden/ Panduit/ Siemon/ Molex/ System-x/ Tyco/Schnider. 2 Each
84 2.35 Supply, installation, Testing and Commissioning of CAT 6 24 port loaded Patch panel for connections etc. as required. (Approved Makes :-Legrand/ Panduit/ D-Link. 3 Each
85 2.36 Supply and installation of 1U 22 Slot Rack Mount Horizontal Cable Manager Duct Raceway for 19" Server Rack of size 48 x 6 x 4 cms. (Approved Makes :-Panduit/Andtronics.) 5 Each
86 2.37 Supplying and fixing 32 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 32 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 5 Each
87 3 Total Flooding NOVEC 1230 Fire Suppression System
88 3.01 Supply, installation testing and commissioning seamless 34 LTR cylinder, PESO approved, complete with valve assembly, syphon tube, pressure gauge complete as required. (Make: FIREGUARDS, CEASEFIRE) 1 Each
89 3.02 Supply, installation testing and commissioning of 3M NOVEC1230 (FK-5-1-12) clean agent gas complete as required. 25 Kg
90 3.03 Supply, installation testing and commissioning Master Kit complete with Electric actuator & Discharge Hose complete as required of approved make as per diredtion. 1 Each
91 3.04 Supply, installation testing and commissioning Discharge Brass Nozzle 180/360 Degree of approved make and design etc complete as required and direction. 8 Each
92 3.05 Supply, installation testing and commissioning NOVEC Sign/Warning Board of approved design as per the direction. 1 Each
93 3.06 Supply, installation testing and commissioning Wall Mount Cylinder Brackets of approved design etc complete as required and as per the direction. 2 Each
94 3.07 Supply, installation testing and commissioning of 2 Zone Gas Release Panel with battery of approved design etc complete as required and as per the direction. 1 Each
95 3.08 Supply, installation testing and commissioning Photo Electric Smoke Detector of approved make and design as per requirement and direction. 2 Each
96 3.09 Supply, installation testing and commissioning Manual Release switch as per requirement and direction. 1 Each
97 3.1 Supply, installation testing and commissioning Manual Abort Switch(Make Ravel) or approved make as per the direction. 1 Each
98 3.11 Supply, installation testing and commissioning 50 MM MS Seamless Pipes as per ASTMA 106GR B, Schedule 40 with necessary fittings including all labour, material, welding etc. complete as per direction. (Pipe Jindel/Prakash, Fitting Venus or equivalent) 4 Meter
99 3.12 Supply, installation testing and commissioning 40 MM MS Seamless Pipes as per ASTMA 106GR B, Schedule 40 with necessary fittings including all labour, material, welding etc. complete as per direction. (Pipe Jindel/Prakash, Fitting Venus or equivalent) 7 Meter
100 3.13 Supply, installation testing and commissioning 25 MM MS Seamless Pipes as per ASTMA 106GR B, Schedule 40 with necessary fittings including all labour, material, welding etc. complete as per direction. (Pipe Jindel/Prakash, Fitting Venus or equivalent) 6 Meter
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail