Supply Of Walk In Cold Rooms ( 50 Nos ) , Ppgi Puf Filled Panels As Per Spec No 3 , 17 , Pcc Concrete Flooring 1:2:4 At Floor Stand ( 1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , Flooring Of Walkincold Room As Per Spec No . 5 , Door With Hinges And Emergency Safety Lock Size 900Mmx2000mm As Per Spec No 4 , Emergency Alarm With Standard Length Of Cable As Per Spec No 4 , Two 5Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Copper Pipes For Refrigeration Unit Additional Requirement , Drain Pipe Additional Requirement , Cables For Refrigeration Unit Additional Requirement , Control Panel With Switches And Alarm As Per Spec , Vapour Proof Lamp 2Nos With Cables And Switches As Per Spec No 14 , External Light With Cables And Switches As Per Spec No 14 , Digital Data Recorder With Temperature Alarm And Sms Alert Facility For Temperature Alarm As Per Spec No 12 , 13 , Ss 304 Grade 14 Gauge Shelves 6X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 5X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 4X3 Feet As Per Spec No 22 , Pvc Blinds For Door Way As Per Spec No 23 , Earthing And Safety Equipments : Supply And Providing Pipe Earthing As Per Is 3043 With 3 . 60M Long 40Mm Dia B Class Gi Pipe , Gi Funnel With Weld Mesh , Filling Requried Quantity Of Charcoal & Salt Including Construction Of Inspection Chamber With A Bed Concrete Of 1:4:8 Pcc Using 40Mm Broken Stone ( 10Cm Thick ) , Brick Work In Cement Mortar 1:6 , Plastering The Surface Of Brick Masonry And The Exposed Surface Of Pcc Bed With Cement Mortar 1:4 , 12Mm Thick , ( The Finished Inside Dimension Shall Be 300X300x300mm ) But Excluding Test Joint , Earth Continuity Conductor To The Plate , And Covering At The Top ( In Ordinary Soil ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required . 4 . 00 Mm Copper Conductor ( 8 Swg ) , Door With Hinges And Emergency Safety Lock Size 1000Mmx2000mm As Per Spec ( Not Taken For Evaluation ) , Emergency Alarm Cable Additional Requirement ( Hooter ) , Two 3Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 4Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 6Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 8Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Additional Digital Display Unit As Per Spec With Standard Length Of Cables As Per Spec , Automatic 3 Phase Change Over , Cable For Additional Digital Display Unit , Demolition Of Old Walkincold Room , Mcbs And Mcb Distribution Boards: Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Busbar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required . 4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator / Rccb / Rcbo As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supply And Fixing Of Following Rating Residual Current Circuit Breaker Having Earth Leakage Protection ( Rccb ) As Per Specification As Required 4 Pole 63 Amps . ( 415 Volts ) , 100Ma Sensitivity , Supply And Fixing Of Following Rating , 10 Ka , Miniature Circuit Breakers Of The Following Series As Required . 6 A To 32 A Tp Mcb , C-Curve Mcb , Supply And Fixing Of Following Rating , 10 Ka , Miniature Circuit Breakers Of The Following Series As Required . 6 A To 32 A Sp Mcb , C-Curve Mcb , Sp Mcb Blanking Plate , Cables And Cabling : Supply Of Following Size 1 . 1 Kv Grade Xlpe Insulated , Pvc Sheathed , Armoured Aluminium / Copper Conductor Cable Conforming To Is 7098 ( Part 1 ) Amended Upto Date . 4 C 16 Sq . Mm Al , Supply Of Following Size 1 . 1 Kv Grade Xlpe Insulated , Pvc Sheathed , Armoured Aluminium / Copper Conductor Cable Conforming To Is 7098 ( Part 1 ) Amended Upto Date . 3 C 10 Sq . Mm Al , Supplying And Making End Termination With Brass Compression Gland And Aluminium / Copper Lugs For Following Size Of Xlpe Insulated Pvc Sheathed Aluminium Conductor Cable Of 1 . 1 Kv Grade As Required-4C 25 Sqmm Sq . Mm Al , Laying And Clamping Of 1No . Pvc Insulated And Pvc Sheathed Armoured Power Cable , 1 . 1Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables , Spacing Of Clamps Not Exceeding 60Cms , Making Good The Damages Colour Washing Etc . As Required 4 Core Cable Of Size Exceeding 6Sq . Mm But Not Exceeding 25 Sq . Mm With Company Fabricated Saddles . , External Over Head Canopy For 2 Outdoor Units If The Compressor Units Are Placed In Open Area , Stablizer 15 Kva 3 Phase Wide Range As Per Spec