Modular Operation Theatre And Associated Works In Department Of Surgery At Gsvm Medical College , Kanpur Construction Of Modular Operation In Department Of Surgery At Gsvm Medical College Kanpur, GSVM Medical College Kanpur-Uttar Pradesh

Uttar Pradesh Jal Nigam-UPJN has published Modular Operation Theatre And Associated Works In Department Of Surgery At Gsvm Medical College , Kanpur Construction Of Modular Operation In Department Of Surgery At Gsvm Medical College Kanpur. Submission Date for this Tender is 15-02-2020. Building Work Tenders in GSVM Medical College Kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

23110270
Corrigendum : Modular Operation Theatre And Associated Works In Department Of Surgery At Gsvm Medical College , Kanpur Construction Of Modular Operation In Department Of Surgery At Gsvm Medical College Kanpur
Open Tender
Indian
Uttar Pradesh
GSVM Medical College Kanpur
15-02-2020

Tender Details

Modular Operation Theatre And Associated Works In Department Of Surgery At Gsvm Medical College , Kanpur Construction Of Modular Operation In Department Of Surgery At Gsvm Medical College Kanpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Jan-2020 time extension Date 27-01-2020
2 25-Jan-2020 date extension Date 15-02-2020

Key Value

Document Fees
INR 23600 /-
EMD
INR 2000000.0 /-
Tender Value
INR 11.65 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OF MODULAR OPERATION THEATRE IN DEPARTMENT OF SURGERY AT GSVM MEDICAL COLLEGE KANPUR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Pre-fabricated Walls & Ceiling Panel BI01010001010000000000000515BI0100001113 960 sqm
2 2 Laminar Air Flow Ceiling BI01010001010000000000000515BI0100001114 8 Nos
3 3 Automatic Hermatically Sealing Door 2100 X 1500 MM BI01010001010000000000000515BI0100001115 8 Nos
4 4 Automatic Hermatically Sealing Door 2100 X 1000 MM BI01010001010000000000000515BI0100001116 8 Nos
5 5 Surgeon Control Panel BI01010001010000000000000515BI0100001117 8 Nos
6 6 LED TWIN Plate X-ray Viewer 8 Nos
7 7 Pressure Relief Dampers 8 Nos
8 8 Anti-Static Flooring 320 sqm
9 9 Storage Cabinets 8 Nos
10 10 2-Bay Scrub Sink 8 Nos
11 11 Writing List Board 8 Nos
12 12 Peripheral Lights (LED) 64 Nos
13 13 Hatch Box 8 Nos
14 14 Electrical Work inside the OT 8 job
15 15 Medical Gas Pipeline work inside the OT 8 job
16 16 Oxygen Manifold Supply System (Without Cylinders) 1 set
17 17 Emergency Oxygen Manifold (Without Cylinders) 1 set
18 18 Duplex Vacuum Pump (Minimum 1000 LPM Each) 1 set
19 19 Vacuum Tank (Capacity 1000ltr.) 1 set
20 20 Electrical Panel, cabling and wiring for Electrical Generator 1 lot
21 21 Operation Theatre Management System (Hardware + Software) 1 Nos
22 22 Dismantling of existing plaster including disposal of refuse as directed by the Engineer in charge within a distance of 60 metre 769.57 sqm
23 23 Dismantling of existing brick work or lime stone or cement morter and including stacking of materials as directed by the Engineer in charge within a distance of 60 metre 20.59 cum
24 24 Class 150 Brick work in 1:4 cement & course Sand mortar in foundation and plinth including supply of all materials, labour and tools and plants etc., required for proper completion of work same as above but in super structure above plinth level up to floor to level (upto 2 storeys) including accessories cuting and moulding of brick work as required and including honey combed including thikness of wall more then 12cm. 32.52 cum
25 25 Provdinng and fixing tiled false ceiling 184.5 sqm
26 26 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 350 kg
27 27 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. 4.55 cum
28 28 Providing and laying integral cement based treatment (Brick coba) for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in - charge and consisting of : (i) 1st layer of 22 mm to 25 mm thick approved and specfied rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement :3 coarse sand) mixed with water proofing compound confirming to IS : 2645 in the recommended proportion over the levelling course (levelling course to be paid separately). Joints sealed and grouted with cement slurrry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Fininshing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sdm throughly embedded in the 2nd layer. 233.65 sqm
29 29 12 mm thick plaster in single coat on fair side of single or half brick thick wall for interior plastering upto floor two level including internal rounded angles chamfers, and/or not exceeding 80 mm. In girth and finished even smooth. No extra for mixing any additive with cement and approved coarse sand ratio of 1:3. 836.32 sqm
30 30 Providing and laying of 8 to 10 mm thick ivory or light shade vitrified tiles of 600x600mm size in wall, flooring or skirting laid with 1:3 (1 cement : 3 coarse sand), finished with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T&P required for proper completion of the work. 410.06 sqm
31 31 2.5cm (1'') thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 2 cm. (1") graded approved stone grit, laid in panels finished with 3 mm (1/8") floating coat of neat cement of cement and marble dust in ratio 5:1 as specified over and including 8 cm (3") thick base concrete consisting of cement, fine sand of 1.25 finesess modulus and brick ballast 4cm. (1.1/2") gauge in proporation of 1:4:8 and removing any overlapping morter at the joints of the penals if any and removing any overlapping morter at the joints of the penals if any and giving them a uniform finish, including supply of all materials, labor, tools & plans etc. required for proper completion of the work. (without base concrete.) 250.96 sqm
32 32 Self Leveling upto 3mm inside OT rooms 8 job
33 33 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Raj Nagar Plain white marble/ Udaipur green marble/ Zebra\nblack marble. Area of slab over 0.50 sqm 14.88 sqm
34 34 Internal water supply & waste material dispose 1 job
35 35 External water & dispose watre work 1 job
36 36 Finishing wall with premium Acrylic smooth Exterior paint with silicone additives fo required shade: including New Work (Two or more coats applied @1.43 ltr/10 sqm over and including priming coat of exterior primer manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 600 sqm
37 37 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials, with 1 mm thick white cement based putty.(wall & Ceiling Surface) 50 sqm
38 38 Supply & Fixing of M.S. Fabrication wire mess jali size 25mm X 25mm heavy labour T & P etc all complete of work. 50 sqm
39 39 Supply and laying of Aluminium conductor PVC insulated armoured served seathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-in-charge, complte in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 240 sq. mm-3-1/2 core 300 rm
40 40 Supply and burying of 600mm X 600mm X 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. Pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15 mm dia G.I. pipe upto switch board (from appron to switch board the cost of C.I. pipe and copper wire will be extra) 30cm square G.I. frame with higned cover masnory housing alternate layers of charcoal/coke ant salt at least 150mm thick around etc. complete in all respect. 8 Nos
41 41 Supply and laying of 32mm X 6mm copper strip from earth electrode directly in the ground as required complete in all respect. 200 Nos
42 42 Supply and burying of Safe Earthing Electrode T-39 Cu Copper Coated, Length upto 3000mm, outer pipe 76.3mm X 3.2mm inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaning capacity along with 30 cm square C.I. frame with hinged cover & masnory housing. (From electrode terminal to switch board, cost of 25 X3 copper Strip will be extra). Make : As approved in UPPWD & CPRI Certified. 8 Nos
43 43 Supply and laying of 25mm X 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. 280 rmt
44 44 Supply and burying of 40mm dia X 4.5 meteres long G.I. Pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG G.I. Wire in G.I. pipe up to appron ( and from appron to switch board the cost of G.I. wire and pipe wil be extra) upto switch board, 30cm square C.I. box with hinged cover masnory encloure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick around etc. as per directions of Engineer-in-Charge complete in all respect. 3 Nos
45 45 Indoor Units (Norminal Capacity) Ceiling Mounted Casssete (Round flow) Type Units with Wired Remote and refnet. Supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 2.08 TR 12 Nos
46 46 Indoor Units (Norminal Capacity) Ceiling Mounted Casssete (Round flow) Type Units with Wired Remote and refnet. Supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 1.65 TR 4 Nos
47 47 Indoor Units (Norminal Capacity) Ceiling Mounted Casssete (Round flow) Type Units with Wired Remote and refnet. Supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 1.32 TR 6 Nos
48 48 Indoor Units (Norminal Capacity) Wall Mounted Hi-Wall Unitys with Wired Remote and Refnet. Supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 1.65 TR 4 Nos
49 49 Indoor Units (Norminal Capacity) Wall Mounted Hi-Wall Unitys with Wired Remote and Refnet. Supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 1.00 TR 4 Nos
50 50 Air Handling Units (For OT) SITC of factory built F.M. Double skin, outer type, thermal beak profile made of 43mm thick panel consisting of G.I. casing of thickness .8mm complete with DIDW backward curved blower fan of static 125 mm, 6 row deep dx copper coil, followed with strip heaters of 1 kw capacity filter section with 50mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron and MERV-13 filter section (99% down to 3 micron), belt drive package with TEDC drive motor (EFF-1) complete with mixing box, drain connections, drain valve, stainless steel drain pump, complete as per above specification. 2500 cfm (125m static) 8 Nos
51 51 PAN TYPE HUMIDEFIRE ( FOR OT) SITC of pan type humidifier of following capacity it shall be constructed from 1 mm thick S.S. sheet with top cover openable for maintenance. The humidifier shall be with quick fill, make up overflow & drain connections. Humidifier shall be insulated with fiber glass of density 32 kg/cm3 shall be cladded with 22 G thick aluminium sheet. the humidifier is divided into two chambers from inside, one bank of heater is always kept on to maintain water temperature between 60-70 with thermostat all controls such as low level cutout, thermostat float valve shall be provide. It shall have its own electrical panel with contators,MCB,Low level cutout, heating thermostat fault including lamp etc n=in thermally. 1.5 KW 8 Nos
52 52 Supply, Installation, testing and commissioning of corded remotes for AHU's. 8 Nos
53 53 Supply, istallation, testing and commissioning o fAHU controller Kit for connecting the outdoor & AHU (including Control Box & AHU expansion kit.) 8 set
54 54 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 41.3mm dia with 19mm thick insulation 36 rm
55 55 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 34.90 mm dia with 19mm thick insulation 24 rmt
56 56 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 28.6 mm dia with 19mm thick insulation 48 rmt
57 57 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 25.40 mm dia with 19mm thick insulation 68 rmt
58 58 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 22.20mm dia with 19mm thick insulation 120 rmt
59 59 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 19.10 mm dia with 19mm thick insulation 32 rmt
60 60 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 15.90 mm dia with 19mm thick insulation 108 rmt
61 61 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 12.70 mm dia with 19mm thick insulation 92 rmt
62 62 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 9.50 mm dia with 19mm thick insulation 224 rmt
63 63 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 6.40 mm dia with 19mm thick insulation 84 rmt
64 64 Supply and fixing of MS perforated cable tray for Copper Piping 150mm X 50mm X 1.6 mm without cover. 144 rmt
65 65 Drain Piping - Providing and fixing of PVC piping complete with fitting, supports as per specifications and insulated with 9mm thick closed cell nitrile rubber insulation. 40 mm 100 rmt
66 66 Drain Piping - Providing and fixing of PVC piping complete with fitting, supports as per specifications and insulated with 9mm thick closed cell nitrile rubber insulation. 32 mm 68 rmt
67 67 Drain Piping - Providing and fixing of PVC piping complete with fitting, supports as per specifications and insulated with 9mm thick closed cell nitrile rubber insulation. 25 mm 120 rmt
68 68 Electrical Panels 1:- Supply, Design, Installation, Testing & Commissioning of LT Panel floor mounted, outdoor type cubical panel made out of 16 SWG thick CRCA sheet, dust and vermin prrof, lockable hinged doors with 16 SWG thick gland plat. Panel will be powder coated of color siemens grey shed. The Panel including providing and fixing the following switchgear as required. (CPRI Approved Vendor) Panel - 1 INCOMER: 1 nos. 500 A TPN MCCB (36KA) with soild netural link (01 No.) NOTE= FOR DETAILED SPECIFICATION REFER TO SCHEDULE G ( BILL OF QUANTITY) 1 set
69 69 Electrical Panels 2:- Supply, Design, Installation, Testing & Commissioning of LT Panel floor mounted, outdoor type cubical panel made out of 16 SWG thick CRCA sheet, dust and vermin prrof, lockable hinged doors with 16 SWG thick gland plat. Panel will be powder coated of color siemens grey shed. The Panel including providing and fixing the following switchgear as required. (CPRI Approved Vendor) Panel - 2 INCOMER:1 nos. 200 A TPN MCCB (36KA) with soild netural link (01 No.) NOTE= FOR DETAILED SPECIFICATION REFER TO SCHEDULE G ( BILL OF QUANTITY) 1 set
70 70 Supply and fixing of DB Box for Cassette and Hi-wall type Indoor units power supply along with 5 Amp, MCB Complete as required 4 set
71 71 Surgeon's Double Arm Pendant (CE Markedfrom notified body or USFDA approved): 8 Nos
72 72 Anaesthetist's Single Arm Pendant ((CE Markedfrom notified body or USFDA approved)): 8 Nos
73 73 OT Light with provision of camera 8 Nos
74 74 Camera System WITH MONITOR (COMPATIBLE FOR O.T. LIGHT) Imported 8 Nos
75 75 UPS System with Isolation Transformer (10KVA) 8 Nos
76 76 Fully Automatic Oxygen Control Panel for Plant Room 1 set
77 77 AGSS System - 1. Duplex/Triplex AGSS System Minimum 1300lpm each 1 Nos
78 78 AGSS System -2. Control Panel for AGSS System 1 Nos
79 79 AGSS System - 3. Remote for ASS System 1 Nos
80 80 AGSS System - 4. Cabling inside Plant Room 1 Set
81 81 Operating Table for General Surgery 4 Nos
82 82 Electrical Generator 500 KVA 1 Nos
83 83 Fluid Waste Disposal System 3 Nos
84 84 Advanced Electrosurgical Unit with Vessel Sealing Technology: 1 Nos
85 85 Supply and laying of Aluminium conductor PVC insulated armoured served seathed, underground cable including rubber ring etc. Complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. 240 sq. mm-3-1/2 core 5 rm
86 86 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. Complete in all respect as per direction of the Engineer-Incharge. 240 sq.mm 15 rm
87 87 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. Complete in all respect as per direction of the Engineer-Incharge. 120 sq.mm 5 rm
88 88 VRV/VRF System: Supply, installation, testing and commissioning of AIR Cooled & Inverter based variable refrigerant volume type split air conditioning system with R410A suitable for 415 + 10%, 50 cycles, The Unit shall consist of indoor units & external condensing units, complete in all respects, inclusive of insulated copper refrigerant piping, drain piping of required size, electrical panel, wiring, control cabling and earthing, stands and supports with all other necessary accessories for proper functioning of the units. Outer Units 10 HP (For OT) BI01010001010000000000000515BI0100001118 8 Nos
89 89 VRV/VRF System: Supply, installation, testing and commissioning of AIR Cooled & Inverter based variable refrigerant volume type split air conditioning system with R410A suitable for 415 + 10%, 50 cycles, The Unit shall consist of indoor units & external condensing units, complete in all respects, inclusive of insulated copper refrigerant piping, drain piping of required size, electrical panel, wiring, control cabling and earthing, stands and supports with all other necessary accessories for proper functioning of the units. Outer Units 20 HP (For OT) BI01010001010000000000000515BI0100001119 3 Nos
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy