Special Repair To Mes Substation Bldg And Toilet , Four Pole Structures , Lt Connections , Cable Duct , Transformers Basements And Allied Infrastructure At Rms Dholpur, BHARATPUR-Rajasthan

Military Engineer Services-MES has published Special Repair To Mes Substation Bldg And Toilet , Four Pole Structures , Lt Connections , Cable Duct , Transformers Basements And Allied Infrastructure At Rms Dholpur. Submission Date for this Tender is 18-01-2020. Cable Tray Tenders in BHARATPUR Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

22978615
Corrigendum : Special Repair To Mes Substation Bldg And Toilet , Four Pole Structures , Lt Connections , Cable Duct , Transformers Basements And Allied Infrastructure At Rms Dholpur
Open Tender
Indian
Rajasthan
BHARATPUR
18-01-2020

Tender Details

Special Repair To Mes Substation Bldg And Toilet , Four Pole Structures , Lt Connections , Cable Duct , Transformers Basements And Allied Infrastructure At Rms Dholpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Jan-2020 Amendment No 01 Date 18-01-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 29000.0 /-
Tender Value
INR 14.50 Lakhs /-

BOQ Items

Name of Work: SPL REPAIR TO MES SUBSTATION BLDG AND TOILET, FOUR POLE STRUCTURES, LT CONNECTIONS, CABLE DUCT, TRANSFORMERS BASEMENTS AND ALLIED INFRASTRUCTURE AT RMS DHOLPUR
SN Item Description Item Code / Make Qty Units
1 1 Taking down chowkats or frames with shutter without taking off shutter from the frame exceeding 1.5 sqm & not exceeding 4 sqm each including cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) all as specified and directed By Engr-in-charge. 3 Each
2 2 Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and removing unserviceable material exceeding 100 mtr as specified. 8 Cum
3 3 Taking down cement plaster of any description on brick or stone walls or from concrete surface including racking out joints hacking for key scrubbing with water etc all as specified. 40 Sqm
4 4 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. 60 Sqm
5 5 Solid PVC door frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet, reinforced with MS square tube supplying and fixing in opening as per specification All as per above description but single side prelaminated PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet. 14 RM
6 6 Factory made solid panel PVC shutter 30 mm thick ( style ) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘ C’ channel having a PVC sheet strip 20 mm width struck inside with solvent cement for style and plain colour PVC sheet for top rail lock rail and bottom rail on either side and as gap inserts for top and bottom rail paneling of plain, colour PVC sheet to be fitted in the MS frame welded / sealed to the styles and rail with suitable PVC sheets beading and jointed together with solvent cement S&F in frame at site as per specification and drawing in SSR part-II .All as per above description but both side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges. 4.5 Sqm
7 7 S&F 150mm long aluminium, anodised, barrel tower bolts of extruded section and fixed. 4 Each
8 8 S&F 100 mm long aluminium handles, cast type, anodised and fixed. 6 Each
9 9 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. 1 Each
10 10 S&F butt hinges medium grade cold rolled 100 mm mild steel and fixed. 9 Each
11 11 Dismantling structural steel work including doors, gates but excluding framed truss etc 1.2 QTL
12 12 S&F Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work confirming to Fe-290 Gde-E-165. 40 KG
13 13 Hacking out old broken glass (any thickness size, quality or description from wooden frames glazed with putty/beads 3.5 Sqm
14 14 S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane 3 Sqm
15 15 S&F 3 mm thick figured glass, frosted head type and glazing with oil putty in square not exceeding 0.50 sqm in each pane. 0.5 Sqm
16 16 M&L glazed ceramic coloured tiles 300 x 450 mm x7mm thick on skirting, dado set and jointed in neat cement slurry and pointed in white cement with pigment to match the surface over 10 mm thick screed in CM 1:4 all as specified. Note : Design, shade and pattern of fixing of tiles shall be as directed by Engr-in-charge 25 Sqm
17 17 M&L non skid ceramic coloured tiles size (400X400 mm,/450 X450 mm,) 7 to 8mm thick (square /rectangular ) in floors set and jointed in neat cement slurry and pointed in white/coloured cement with pigment to match all as specified. 35 Sqm
18 18 M&L 25 mm thick PCC 1:2:4 type B-1 using 20 mm stone aggregated as in floor finished rough. 35 Sqm
19 19 M&L 15 mm thick for screed bed or bedding layer of CM 1:4 for laying floor finishes. 35 Sqm
20 20 S & F vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests & 'P' trap complete all as specified. 1 Each
21 21 S&F in repair PVC low level flushing cistern 10 Litres capacity white with inlet ball value, float valve and handle including brackets, PVC flush pipe complete. 1 Each
22 22 S & F vitreous China urinal ,Half stall type white with grating and union for discharge pipe ( excluding flushing cistern flush pipe and waste pipe) 1 Each
23 23 S&F Waste pipe 32 mm dia 550mm long PVC for urinal. 1 Each
24 24 S&F PVC connection 15 mm x 450 mm including brass check nut at both ends screwed for iron pipe of 15 mm bore. 2 Each
25 25 S&F Bib tap cast copper alloy with crutch or butterfly handle, chromium plated fancy type screwed for iron pipe, suitable for 15 mm bore complete all as specified. 1 Each
26 26 S&F in repair angle valve cast copper chromium plated screwed down, high pressure with capstan head suitable for 15 mm bore, screwed both ends for iron pipe complete all as specified. 2 Each
27 27 S&F stainless steel gratings of outer frame dia 150 mm open able type including all necessary fittings such as hinges including embedding in tiles with white cement. 2 Each
28 28 S & F 600 mm x 450 mm beveled edge mirror or selected quality glass mounted on 6 mm thick AC building boards or commercial plywood and fixed to wooden plugs with chromium plated brass screwed and cup washers. 1 Each
29 29 M&L rendering 15mm thick in cement mortar 1:6 finished even and smooth without using extra cement on brick/stone masonry surfaces complete all as specified. 10 Sqm
30 30 M&L rendering 15mm thick in cement mortar 1:4 finished even and smooth without using extra cement brick/stone masonry surfaces complete all as specified. 30 Sqm
31 31 Taking down GI tubing of 15 mm dia and connection and including cleaning for refixing or removal all as specified. 5 RM
32 32 Taking down GI tubing of 20 mm dia and connection and including cleaning for refixing or removal all as specified. 5 RM
33 33 S&F 15 mm dia galvanized pipes medium grade with all fittings and fixed complete wall and ceiling or laid in floors. 5 RM
34 34 S&F 20 mm dia galvanized pipes medium grade with all fittings and fixed complete to wall and ceiling or laid in floors. 5 RM
35 35 PCC 1:3:6 type C-2, 50 mm thick using 20mm graded stone aggregate as in plinth protections. 24 Sqm
36 36 S&F PVC (SWR) vent cowl 75 mm bore. 1 Each
37 37 S&F PVC (SWR) WC connector with lip ring 110 mm all as specified. 1 Each
38 38 S&F PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement 1 Each
39 39 S&F in repair PVC SWR pipes 110 mm bore single socket in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps all as specified and directed . 3 RM
40 40 S&F in repair PVC SWR pipes 75 mm bore single socket in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps all as specified and directed. 3 RM
41 41 Dismantling/ disconnecting/ demolition of water storage tank of any type or description and removing from site or refixing in position. 1 Each
42 42 S & F rotational moulded polyethylene water storage tank with float valve, plastic lid cover, double layered, cylindrical vertical with closed top hoisted and fixed in position of capacity 500 ltrs including making connections complete all as specified. 1 Each
43 43 M&L for preparation of new plastered surfaces of wall and applying two coats of white wash complete. 10 Sqm
44 44 M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer with hand roller complete all as specified. 30 Sqm
45 45 M&L for preparation of old plastered surfaces and applying two coats of white wash on ceiling complete all as specified. 40 Sqm
46 46 Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground. 40 RM
47 47 M & L PCC (1:3:6) Type C-2 using 40mm graded stone aggregate as in foundation. 0.5 Cum
48 48 S&F Mild steel work as in hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, noising to steps including embedding in concrete and screwing etc wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc, and similar work confirming to Fe-290 Gde-E-165 120 Kg
49 49 S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc10 cm but n. exc. 15 cm long. Dia of neck 11 to 15 mm. 6 Kg
50 50 S&F chain link MS galvanised fencing 4mm dia 50mmX 50mm mesh including line wire, fixed to angle iron fencing post all as specified and directed by Engineer In charge. 70 Sqm
51 51 M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide on new surfaces of steel or iron. 7 Sqm
52 52 Roughning surface of old concrete floor by picking , sweeping , clean and washing down with water to remove dust etc including brushing neat cement slurry with 3.00 Kg of cement per sqm 30 Sqm
53 53 M&L for cutting grooves in stone walls 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 all as directed. 15 RM
54 54 M&L for providing PCC (1:2:4) type b0 12.5 mm graded stone aggregate as in roof kerbs rounded or chamfered on edges. 0.5 Cum
55 55 Rendering 15 mm thick in cement mortar 1:4 as on roof slabs, finished even and fair mixed with water proofing compound. (For water proofing treatment over roofs) 30 Sqm
56 56 Supply only water proofing compound ISI marked. 4 Kg
57 57 M&L APP based polymeric membrane not less than 3mm thick surface shall be painted with one coat of of cold bitumen primer @ 0.40 kg per sqm conforming to IS: 3384 A layer of minimum weight not less than 3.5 kg/sqm reinforced with polyester non -woven fabric (weighing not less than 150 gm/sqm) and upper side of membrane thermally insulated with white mineral gravel finish uniformly embedded during manufacturing process shall only used. Side overlap shall be 75 mm and ends shall be 100 mm and all over lap and joints shall sealed by torch application all as specified application of polymeric membrane shall be torch application all as per manufacturer's instructions. 30 Sqm
58 58 M&L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base of floor. 40 Sqm
59 59 M&L for sand filling under floors (25mm thick) or in foundations including watering and consolidating. 1 Cum
60 60 M&L for machine pressed precast concrete interlocking paver block, 80mm thickness, M-40 grade of any shape and size confirming to IS-15658-2006, with grey cement and no pigment complete all as specified and directed. 30 Sqm
61 61 M&L for machine pressed precast concrete interlocking paver block, 80mm thickness, M-40 grade of any shape and size confirming to IS-15658-2006, with grey cement and pigment complete all as specified and directed. 10 Sqm
62 62 Taking down and dismantling of old unserviceable 4 pole structure from the existing location, dismantling of ACSR conductors, unserviceable GODs, UG cables, steel structures, insulators, etc and removing from site without leaving any scrap part of the pole structures at site including leveling and giving good finish of PCC work 1:3:6 (C-2) etc as per existing position all as specified and as directed by Engineer-in-Charge. 1 Each Job
63 63 Taking out of UG cable disconnecting from switch gears/poles, pulling out from trenches and walls etc complete all as specified and directed by Engr-in-Charge. 465 RM
64 64 Dismantling of old unserviceable oil circuit breakers any size and type and transporting to E/M store yard for further necessary action all as specified and directed by Engineer-in-Charge. 1 Each Job
65 65 Dismantling of old metering equipments any size and type and transporting to E/M store yard for further necessary action all as specified and directed by Engineer-in-Charge. 1 Each Job
66 66 Taking out old unserviceable LT panel board of any size and capacity all as specified and as directed by Engineer-in-Charge 1 Each Job
67 67 Demolition of cracked edges and corners of duct and cleaning/removing old cable clamps/PCC debris/Soil/Sand or any foreign material, removing burnt out unserviceable cables of any size and type, pulling out the corroded out plates of any size and type, removing deposited slit, mud, and disposing as eco friendly manner all as specified and as directed by Engineer-in-Charge. 42 RM
68 68 M&L for MS sheet duct cover of thick not less than 2mm thick , chequer designed on top, suitable for cable duct cover of size n.exc 60cm wide, 1.6mm thick, including cutting to the size of duct width for covering the duct in any direction including bending, or turning up , mitred angles etc as required all as specified and as directed by Engineer-in-Charge 24 Sqm
69 69 Dismantling of old PCC poles any size and type and removing from site and levelling the area as per existing position all as specified and directed. 2 Each Job
70 70 Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables erection of poles / struts/stays etc not exceeding 10 Sqm on plan, not exceeding 1.5 metre in depth and getting out in soft/disintegrated of soil. 210 Cum
71 71 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil. 205 Cum
72 72 Removing of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point 5 Cum
73 73 Supply & laying sub class B bricks, locally available of size 230x115x40mm suitable for HT/LT cable protection cover all as specified and as directed by Engineer-in-Charge. 3900 Each
74 74 M &L local river sand for bedding and sand cushioning of all LT UG cable all as specified and directed by Engineer-in-Charge. 30 Cum
75 75 M&L for PCC (1:2:4) type B2 with using 40mm graded aggregate as in foundation and mass filling concrete for LT panel boards and in addition where ever directed by Engineer-in-Charge. 2 Cum
76 76 M&L for re-laying of serviceable HT UG cables of 95 sqmm or any, in same trench after checking damages and ensuring trouble free electric power supply to end user all as specified and as directed by Engineer-in-Charge. 136 RM
77 77 M&L for cross arms C shaped or angle type as per site requirement, bracings, supports, clamps and back plates etc fabricated from structural steel section including nuts bolts and washers, welding, bending, cold or hot, drilling holes for bolts, in any shape and any length as per site requirements all as specified and directed by Engineer in Charge. 4 QTL
78 78 S&F Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work confirming to Fe-290 Gde-E-165. Note: Rates including two coat zinc Chrome primer and one synthetic enamel paint over the fabricated structure. 200 Kg
79 79 Supply and erect steel tubular swaged pole 11 metres high, with finial tapper, to arrange 6 pole structure at an average distance pole to pole not less than 3 metres, comprising CI base plate, type 410 SP-55, including nuts, bolts, washers etc all as specified and as directed by Engineer-in-Charge. 8 Each
80 80 M&L for stringing ACSR conductor on poles 2 to 3 runs of wiesel or more as per site requirement with permissible sag as per IS rules etc all as specified and directed by Engineer in Charge. 0.6 QTL
81 81 Supply and fix Disc insulator porcelain vitreous 11KV grade 145mm high, 255mm dia ball and socket type White/Brown/Green in colour suitable to string ACSR conductor, fixed on channels or directly on poles all as specified and ad directed by Engineer-in-Charge. 9 Each
82 82 Supply and fix Pin insulator porcelain vitreous 11000 volts grade, 150mm high, 150mm dia, nuts, bolts and washers etc, galvanised MS spindle , washers fixed on channels or directly on poles all as specified and as directed by Engineer-in-Charge. 21 Each
83 83 M&L for GOD (Air Break Switches) 11KV, outdoor type, suitable for vertical mounting type fitted on channels at specified distance, of rating upto 400 amps, suitable for operation at ground level, and all accessories such as GI pipe, handle bar, gloves , pin all as specified and as directed by Engineer-in-Charge 4 Each Set
84 84 S&F expulsion type porcelain drop out fuse unit single 11KV grade, upto 25 amps capacity including copper fuse wire mounted on channels and insulators with complete assembly all as specified and as directed by Engineer in Charge. 12 Each
85 85 Supply and fix Lightning arrester expulsion type on 4 pole structure top including connecting GI earth strip 25x4mm thick with suitable mounting clamps and brackets, getting down upto above the ground level ,11000V grade 65KA station class all as specified and as directed by Engineer-in-Charge. 2 Set of Three
86 86 Supply and fix cable jointing kit with complete for 11000V grade for outdoor termination heat shrink type jointing material/flaming and accessories suitable for 3 core XLPE, Al conductor cable of size 95Sqmm. 4 Each Set
87 87 Supply and fix cable jointing kit cold shrink type with complete for 11000V grade for straight through type, jointing materials and accessories suitable for 3 core XLPE, Al conductor cable of size 95Sqmm. 2 Each Set
88 88 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured ,electric power cable (heavy duty) with stranded aluminium conductor 11KV grade , 3 core of size 95 Sqmm. 235 RM
89 89 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100V grade , 3.5 core of size 95 Sqmm. 94 RM
90 90 M&L for loose filling / hardcore packing of stone aggregates of gauge not exceeding 63mm boulders in switch yard for arresting fire and arc , upto thickness n.exc 15cm, around 4 pole structure in 11KV MRS all as specified and as directed by Engineer-in-Charge. 60 Cum
91 91 Supply and lay GI tubing light grade flanged or socket end laid in trenches or on ground or through pillars/steel poles/structures where ever directed of size 80mm bore including screwed sockets, bends, clamps, Connectors, back nuts, diminishing pieces etc as required all as specified and directed by Engineer in Charge. 18 RM
92 92 M&L stay wire complete length 7/4.0mm Grade 2 with securing and clamping on stay assembly all as specified and directed by Engineer in Charge 0.6 QTL
93 93 M&L stay assembly complete set of size 16mm rod with accessories as shown electrical plate No.1, including loop type insulator stay clamp etc all as specified and directed by Engineer in Charge. 10 Each Set
94 94 S&F Anti climbing devices, comprising 2.24mm dia galvanised steel 2 strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 mtr clamped and properly secured or as ordered all as specified and as directed by Engineer-in-Charge. 0.5 QTL
95 95 Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20cm size. 2 Each
96 96 M&L for GI guard wire 4mm dia including making cradles etc over the bldg and road crossings etc all as specified and as directed by Engineer-in-Charge 25 Kg
97 97 Design Fabricating supply and erecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system Indoor type front opening type, ,separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out , incoming and outgoing feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 2 mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Angle iron frame of 50x50x6mm thick duly painted and embedded in PCC 1:3:6 45 CM below ground level and 15 Cm above ground level and consisting the following:- 1 Each
98 97.1 (a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 400 Amps for phases and neural set of 4 for RYB &N set of 04 -01 set
99 97.2 (b) Digital Amp Meter 0-300 Amp, 3 phase with 3 Nos CT of Suitable ratio- 1Set
100 97.3 (c) Digital Volt Meter 0-500 Volts , 3 phase - 1No
101 97.4 (d) Digital multi function meter for KW, KVA, Pf Frequency QUSAR- 1No
102 97.5 (e) INCOMING:-\n(i) MCCB 4 pole TPN, 250Amps capacity prewired and connected with distribution bus bar, 36-50KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting - 01No.\n(ii) Auto Transfer switch with controller 200Amps capacity, pre wired, cabling works, mounted on same panel board 415V, 4pole, with electronic digital display etc, make havells, cat Part No IHYTCDE200 - 01 No.\n
103 97.6 (f) OUT GOING:-\n(i) MCCB 4 pole 200Amps capacity, 35 KA beaking capacity\n - 02 Nos.\n(ii) MCCBs 4 pole, 63Amps capacity, 25 KA breaking capacity, 415V, adjustable thermal & adjustable magnetic setting -01No\n(iii) .MCCB 4 pole, 100Amps capacity, 25KA breaking capacity, 415V - 02 Nos\n
104 98 M&L for earth continuity conductor of GS strip size 25mm. 4mm upto the connecting point including suitable jointing all as specified and as directed by Engineer-in-Charge. 56 RM
105 99 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised iron strip of size 25mm x 4mm as earth lead by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 pre-cast MS sheet cover 30cmx30cmx3.15mm thick with one handle for lifting made out of 8mm dia MS bar, watering pipe 20mm bore galvanized iron pipe (medium grade) with MS funnel for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soil complete all other accessories as shown on electrical plate No 3 of MES Sch Pt-I all as specified and directed. 8 Each Set
106 100 Schedule of Credit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy