Indian Oil Corporation Limited-IOCL has published Design , Supply , Installation , Testing And Commissioning Of Automation Of Tank Truck Loading System , Tank Farm Management System , Ip Based Cctv Surveillance System , Access Control System , Fire Alarm System , Hydrocarbon Vapour Detection Syst. Submission Date for this Tender is 20-01-2020. Access Control Systems Tenders in Motihari,Bihar Bihar. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Jan-2020 | Extension of Bid Submission date | Date | 20-01-2020 |
Name of Work:Design, supply, installation, testing and commissioning of automation of Tank Truck Loading System, Tank Farm Management System, IP Based CCTV Surveillance System, Access Control System, Fire Alarm System, Hydrocarbon Vapour Detection System, Fire Fighting Automation System etc along with associated works at Motihari Terminal, Bihar | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 10 | SUPPLY COMPONENTS | 10 | ||
2 | 20 | TANK LORRY FILLING | 20 | ||
3 | 30 | Supply of Microprocessor based Coriolis mass flow meter for white oil application along with display unit and mounting accessories with adjustable screw support,bellow for vibrations etc complete as per specifications and tender document for loading of following main products \nNote: In case MFM is not having inbuilt ASTM table, vendor has to supply Flow Computers along with accessories as per tender document at no additional cost to IOCL. | 30 | ||
4 | 40 | MS (for line size of 100 mm ) | 40 | 8 | EA |
5 | 50 | HSD (for line size of 100 mm ) | 50 | 12 | EA |
6 | 60 | Water (Master MFM for TT calibration) for line size 50 mm along with structural support and required accessories for mounting | 60 | 2 | EA |
7 | 70 | Supply of Strainer cum Air eliminator with differential pressure transmitter with display unit & keyboard across the Strainer along with accessories, SS tubing, needle valves etc complete as per specifications and tender document. | 70 | ||
8 | 80 | For product line size 100 mm - TLF | 80 | 20 | EA |
9 | 90 | For Water Line size 50 mm - TT calibration (along with structural support and required accessories) | 90 | 2 | EA |
10 | 100 | Supply of Multistage Piston type Digital Control Valve (DCV) along with TRV with two nos. isolation valves at inlet and outlet of TRV with associated piping , secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete as per specifications and tender document. | 100 | ||
11 | 110 | For product line size 100 mm - TLF | 110 | 20 | EA |
12 | 120 | For Water Line size 50 mm - TT calibration along with vacuum breaker & isolation ball valve mounted on a spool piece & mounting accessories so that the entire water after DCV is drained into the TT after completion of each batch during TT calibration. | 120 | 2 | EA |
13 | 130 | Supply of piston type, hydraulically operated ON-OFF Valve along with accessories, secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning ,tubing arrangement as per installation drawing etc for line size 100 mm complete as per specifications and tender document. | 130 | 1 | EA |
14 | 140 | Supply of Triple Offset Butterfly valve with electrical/electro-hydraulic fail safe actuator ON-OFF along with accessories as per installation drawing etc for line size 100 mm complete as per specifications and tender document. | 140 | 20 | EA |
15 | 150 | Supply of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. isolation ball valve, Aluminium canopy/sunshade with mounting accessories etc on the TLF metering skid complete as per specifications and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2) | 150 | 26 | EA |
16 | 160 | Supply of flameproof cum weather proof, Temperature transmitter along with display unit and keypad, RTD, Thermo well, mounting accessories etc complete as per specifications and tender document. \nNote:Mounting at each TLF loading point on main product for line size 100 mm | 160 | 20 | EA |
17 | 170 | Supply of online proving valves manifold comprising of 1 no. manual operated DBBV without actuator and 2 nos. of 100 NB, full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF MFM complete as per specifications and tender documents. | 170 | 20 | SET |
18 | 180 | Supply of bottom loading arm of size 100 mm NB along with 1 no. full bore isolation ball valve (100 mm), API Coupler, break away coupler, parking stand with compatible API adaptor, Ex-proof/intrinsic safe position sensor for parking stand, associated piping for connecting loading arm with the metering skid , mounting structure etc complete as per specifications and tender document. Application: MS, HSD | 180 | 20 | EA |
19 | 190 | Supply of vapour recovery arm of size 80 mm NB having 3” (80 NB) with poppeted vapour coupler, break away coupler, NRV, flame arrestor, reducers, mounting structures, parking stand with compatible API adaptor, associated accessories, mounting structure etc complete as per specifications and tender document.\nApplication : MS | 190 | 8 | EA |
20 | 200 | Supply of Ex-proof Rack Monitors for TT overfill protection system along with accessories like 10 pin gantry plug, ATC copper coiled cable of minimum 8m as per API RP1004 including required support for mounting of the Rack Monitor and gantry plug, etc complete as per specifications and tender document.\nNote: In addition to above, minimum 2 nos. portable Rack Monitor along with accessories and 2 nos. lockable bypass switch are to be provided against total supply of Rack Monitor. | 200 | 12 | EA |
21 | 210 | Supply of Resistance - Capacitance type Tank Truck grounding unit along with accessories like 3 nos. of heavy duty flexible coiled cables with high quality rugged, heavy duty SS/ brass grounding socket, FLP double compression glands, Ex-Plug, mounting structure etc, complete as per specification and tender documents.\nNote: (2 nos. of coiled cable with socket for TT earthing relay interlocks and 1 no. for separate earthing of TT) | 210 | 12 | EA |
22 | 220 | Supply of heavy duty SS/brass earthing bolt compatible with offered earthing socket of the grounding unit for mounting on the Tank truck along with accessories like SS nut, lock washer etc complete as per specification and tender document. | 220 | 2000 | EA |
23 | 230 | Supply of Ex-proof field mounted Remote Interaction Terminal (RIT) along with FLP double compression glands and Ex-Proof-plugs, structural supports etc complete as per specifications and tender documents. | 230 | 20 | EA |
24 | 240 | Supply of Ex-proof field mounted Driver Ack Push Button station along with FLP double compression glands and Ex-Proof-plug, structural supports etc complete as per specifications and tender documents. | 240 | 20 | EA |
25 | 250 | Supply of Microprocessor based Field mounted dual arm Batch Controller with interface to minimum 2 nos. of main product + 2 nos. of blend product + 2 nos. of additive product in Flameproof and weather proof enclosure along with accessories like double compression glands, Exd Plugs, hoods, structural supports etc complete as per specification and tender document.\n\nAlternatively vendor can supply 2 sets of Microprocessor based Field mounted single arm Batch Controller with interface to minimum 1 no. of main product + 1 no. of blend product + 1 no. of additive product in Flameproof and weather proof enclosure along with accessories like double compression glands, Exd Plugs, hoods, structural supports etc in place of Dual Arm Batch Controller complete as per specification and tender document. | 250 | ||
26 | 260 | For TLF product loading | 260 | 12 | EA |
27 | 270 | For TT calibration with water | 270 | 1 | EA |
28 | 280 | Supply of intrinsically safe / flameproof type proximity card reader along with mounting accessories etc complete as per specifications and tender document for authorisation of TT at | 280 | ||
29 | 290 | TLF bays (1 no. Per bay) | 290 | 12 | EA |
30 | 300 | License area Entry barrier gates ( 2 nos. X 2) | 300 | 4 | EA |
31 | 310 | License area Exit barrier gates ( 1 no. X 3) | 310 | 3 | EA |
32 | 320 | Security Exit barrier gates ( 1 no.) | 320 | 1 | EA |
33 | 330 | Security Entry barrier gates ( 1 no.) | 330 | 1 | EA |
34 | 340 | Near Security Gate/TT parking ( for TT registration ) | 340 | 2 | EA |
35 | 350 | Supply, configuration and testing of Scratch proof, waterproof Smart cards along with messages printed compatible with proximity card reader complete as per specifications and tender document. | 350 | 1500 | EA |
36 | 360 | Supply of pre-fabricated Metering Skid (MS structure) for mounting of complete metering equipments as per BOQ and schematic drawing for one main product, one blend product and one additive dosing system. The metering assembly comprises of : \n\nMain product line: Strainer cum Air eliminator, Spool piece with tapping for additive dosing, Online Master Meter proving manifold, MFM,Spool piece with tapping for Temprature Transmitter installation, Pressure transmitter, spool piece with tapping for connecting outlet of TRV, ON-Off valve, DCV, Spool Piece with tapping for Ethanol blending & TRV installation. \n\nBlend Product line: Strainer cum air eliminator, Online Master Meter proving manifold, MFM, Spool piece with tapping for Temperature Transmitter installation, ON-Off valve, DCV, NRV, isolation valve and finally connected to Main stream line tap off point after DCV. \n\nAdditive Dosing System comprises of isolation valve, Additive injection mono block, connecting piping, NRV, isolation valve and finally connecting to Main stream tap off point before MFM. \n\nProvision to be made in the skid for mounting of Batch Controller, Rack Monitor, Grounding unit, RIT, Driver's Ack Push button stations, card reader, FLP sockets, FLP junctions boxes (Power, Signal and Control), FLP power isolator switch, interconnecting cables from respective equipment to JBs, cable trays with covers, glands, support, MS structure,Electroforged galvanized grating, nuts, bolts, gaskets, Tees, bends, elbows, WNRF flanges, nozzles, plugs, isolators, any other equipment if required as per design Engineering etc complete as per specification and tender document. \n\nKindly note, irrespective of facility available or not, each metering skid shall have provision for installation of metering assembly of one main product, one blend product and one additive product as detailed in tender document. \n\nItems including the provision for skid for calibration meters as well. | 360 | 20 | TO |
37 | 370 | Note: \n1. All the equipments, JBs, cable trays, interconnecting cables etc as stated above to be installed and loop tested at factory. Complete assembly to be dispatched at site. The skid to be designed and fabricated by the party taking into consideration of all the equipment sizing, space available for mounting of the skid at the bottom of the gantry etc. The design Engineering along with weight calculation of individual skid excluding equipments to be submitted to IOCL prior to taking up fabrication job for review purpose. Payment shall be made based on theoretical weight calculation of the skid excluding weight of equipments, JBs, cable trays. The rate is also inclusive of surface preparation, painting, transportation of the skid to site etc complete in all respect. \n2. All unuse nozzle/ tapping/ opening to be blind flanged.\n3. For SKO metering SKID, tapping to be provided in the skid for both bottom and top loading as per design Engineering.\n | 370 | ||
38 | 380 | Supply of barrier gate of minimum boom length of 3 m along with accessories, controllers etc complete as per specification and tender document for installation at following location. | 380 | ||
39 | 390 | License area Entry gate | 390 | 2 | SET |
40 | 400 | License area Exit gate | 400 | 3 | SET |
41 | 410 | Security Exit gate | 410 | 1 | SET |
42 | 420 | Security Entry gate | 420 | 1 | SET |
43 | 430 | DISPLAY BOARDS | 430 | ||
44 | 440 | Supply of weather proof LED bay queuing display board (Minimum 15 lines x 100 mm Character height x 25 characters per line) for outdoor installation at TT parking area / Customer service building along with accessories like public address system, speakers, amplifier, mike, structural steel for mounting of the same, Aluminium canopy/sunshade etc complete as per specifications and tender document. | 440 | 1 | EA |
45 | 450 | Supply of LED monitor of minimum 55" along with required hardware and software for interfacing with TAS, lockable enclosure (wall / ceiling mounted) for mounting the monitor along with accessories at Driver's Rest Room for repeat display of 15 lines Bay Queue Display board complete as per specification and tender document. Kindly note, no additional payment shall be made for any additional hardware/ software/ cable etc required for integration of the monitor with TAS. | 450 | 1 | EA |
46 | 460 | Supply of LED monitor of minimum 55" along with required hardware and software for interfacing with TAS, lockable enclosure (wall / ceiling mounted) for mounting the monitor along with accessories, Aluminium canopy/ sunshade etc at invoice room for displaying the list of TTs whose invoice has been generated and TT is still inside license area complete in all respect as per tender requirement. Kindly note, no additional payment shall be made for any additional hardware/ software/ cable etc required for integration of the monitor with TAS. | 460 | 1 | EA |
47 | 470 | Supply of weather proof three line coloured LED display board with scroll and flash effects (Each line of min. 50 mm Character height x 11 characters per line) for outdoor application near Security Gate/ TT parking Area and license area Entry barrier Gate along with mounting structure, Aluminium canopy/ sunshade, accessories etc complete as per specifications and tender document for displaying the TT Registration no. in bilingual (English + local language) of reported TT whose proximity card has been shown on the PCR adjacent to the display board for TT reporting at security gate/TT parking area, TT status at TT parking area exit gate and the bay no. (Bilingual) etc of the authorised TT reported at license area Entry Gate as per FDR.\n2 nos. for TT reporting + 1 no. at Security Entry gate + 2 nos. per License Area Entry Barrier Gate (2X2) + 1 No. at Security Exit gate; Total - 2+1+4+1=8\nNote : 1 line for display in English & 2 lines for displaying in local language | 470 | 8 | EA |
48 | 480 | Supply of 3 KL Stainless Steel Mobile Prover tank along with accessories like flanges, ball valves, calibrated sight glass, plunger, hoses, blind flanges, etc mounted on Trailer chassis along with wheels with solid rubber tyres complete as per specifications and tender document.\nNote: Vendor to arrange for prime mover for calibration of MFM at site during entire commissioning and CAMC period at no additional cost to IOCL. | 480 | 1 | SET |
49 | 490 | Supply of Mobile Master meter (Master MFM) proving system for line size 100mm consisting of Master Mass flow meter with display unit, Master Temperature Transmitter with RTD with Thermo-well, Mounting accessories suitable for installation on 4" line size, 2 nos. isolation ball valve of 100mm, hose pipe, trolley mounted Master Meter Skid with suitable wheels, FLP JB, FLP double compression glands, power adapter along with accessories (if required) for powering of Master Meter, FRLS Copper Armoured Power & Signal Cable of minimum 15m each with compatible FLP power plugs for powering the MFM, integration of Mobile Master MFM with TAS and integration of temperature transmitter with Master MFM, supports for mounting the equipments, pipes, flanges, reducers, gaskets, nuts, bolts, studs etc complete as per specification and tender document. | 490 | 1 | SET |
50 | 500 | Ethanol Dosing System | 500 | ||
51 | 510 | Supply of Microprocessor based Coriolis mass flow meter for white oil (Ethanol) application alongwith display unit and mounting accessories with adjustable screw support, reducer (if required) etc for line size 2" suitable for maximum flowrate of 500 LPM complete as per specifications and tender document for ethanol blending.\nNote: In case MFM is not having inbuilt ASTM table, vendor has to supply Flow Computers along with accessories as per tender document at no adddtional cost to IOCL . | 510 | 8 | EA |
52 | 520 | Supply of Strainer cum Air eliminator for line size 50 mm with differential pressure transmitter across the Strainer along with accessories, SS tubing, needle valves etc complete as per specifications and tender document. | 520 | 8 | EA |
53 | 530 | Supply of Multistage Piston type Digital Control Valve (DCV), NRV, isolation valve for line size 50 mm alongwith accessories, with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete as per specifications and tender document. | 530 | 8 | EA |
54 | 540 | Supply of Piston type, hydraulically operated, solenoid operated ON-OFF Valve along with accessories, with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves , tubing arrangement as per installation drawing etc for line size 50 mm complete as per specifications and tender document. | 540 | 8 | EA |
55 | 550 | Supply of flameproof cum weather proof, Temperature transmitter along with display unit and keypad, RTD, Thermowell for line size 50mm, mounting accessories etc complete as per specifications and tender document. \nNote : One no. of additional thermo well along with accessories to be provided and installed on ethanol point for installation of Master Temperature transmitter with RTD. | 550 | 8 | EA |
56 | 560 | Supply of online proving valves manifold comprising of 1no. manual operated DBBV without actuator and 2 nos. of 50 NB, full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF MFM complete as per specifications and tender documents. | 560 | 8 | SET |
57 | 570 | Supply of 1 KL Stainless Steel Mobile Prover tank alongwith accesories like flanges, ball valves, calibrated sight glass, plunger, hoses, blinds flanges, etc mounted on Trailer chassis along with wheels with solid rubber tyres complete as per specifications and tender document.\nNote: Vendor to arrange for prime mover for calibration of MFM at site during entire commissioning and CAMC period at no additional cost to IOCL. | 570 | 1 | SET |
58 | 580 | Supply of Mobile Master meter (Master MFM) proving system for line size 50mm consisting of Master Mass flow meter with display unit, Master Temperature Transmitter with RTD with Thermo-well, Mounting accessories suitable for installation on 2" line size, 2 nos. isolation ball valve of 50 mm, hose pipe, trolley mounted Master Meter Skid with suitable wheels, FLP JB, FLP double compression glands, power adapter along with accessories (if required) for powering of Master MFM, FRLS Copper Armoured Power & Signal Cable of minimum 15 m each with compatible FLP power plugs for powering the MFM, integration of Mobile Master MFM with TAS and integration of temperature transmitter with Master MFM, supports for mounting the equipments, pipes, flanges, reducers, gaskets, nuts, bolts, studs etc complete as per specification and tender document. | 580 | 1 | SET |
59 | 590 | Additive dosing System | 590 | ||
60 | 600 | Supply of additive injection mono block along with accessories for XTRAPREMIUM and XTRAMILE complete as per specification and tender document. \nNote - All the wetted parts within Additive injection panel/ block shall be of SS 316 or better. | 600 | 4 | SET |
61 | 610 | Supply of Additive tanks (500 Litres each) and pump module for XTRAPREMIUM /XTRAMILE comprising of Additive Tank, Additive Pumps (Two per tank) , Mild Steel SKID, Flameproof Motor, NRV 25 mm, Flanged ball valve 25 mm, Pressure Relief Valve, Pressure Gauge with pulse dampener, Strainer 25 mm, interconnecting pipings (25 mm SS), flanges etc. auxiliary potential free contact/serial communication complete as per specification and tender document. | 610 | ||
62 | 620 | For Xtramile | 620 | 1 | SET |
63 | 630 | For XtraPremium | 630 | 1 | SET |
64 | 640 | Supply of ASTM A106 Gr B Schedule 80 pipe of 25 NB from additive header pipe to additive injection panel at TLF bay complete as per tender document.. | 640 | 200 | M |
65 | 650 | Supply of Necessary hardware Like SS Tubing, reducer, Elbows, equal Tee ,unequal tee, Flanges, Coupling, Ball Valve for Isolation, NRV, 15 mm back pressure regulator on return line etc as required for piping and commissioning of the system complete in all respect. | 650 | 1 | LS |
66 | 660 | Note: Piping from Additive tank skid upto TLF header line up to meter skid along with isolation valve & return line shall be supplied and installed by IOCL. Integration of additive pumps for remote operation, level measurement shall be in the successful bidder's scope. | 660 | ||
67 | 670 | TLF Header line instruments | 670 | ||
68 | 680 | Supply of Bulk Air Eliminator as per product line size and flow requirement as per following sizes including mounting structure, foundation etc complete as per specification and tender document. | 680 | ||
69 | 690 | MS - 2.6 KL | 690 | 1 | EA |
70 | 700 | HSD - 2.6 KL | 700 | 1 | EA |
71 | 710 | ETHANOL-0.6 KL | 710 | 1 | EA |
72 | 720 | Supply of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. isolation ball valve, Aluminium canopy/sunshade with mounting accessories etc on the TLF main header line complete as per specifications and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2) | 720 | ||
73 | 730 | TLF Header | 730 | 3 | EA |
74 | 740 | Tank Farm Management System | 740 | ||
75 | 750 | Supply of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 750 | ||
76 | 760 | For Cone Roof Vertical Tanks (Primary and Secondary Radar Gauges) | 760 | ||
77 | 770 | HSD | 770 | 6 | EA |
78 | 780 | BIO-DIESEL | 780 | 2 | EA |
79 | 790 | PCK | 790 | 4 | EA |
80 | 800 | For Internal Floating Roof vertical tanks/Floating roof vertical tanks (Primary and Secondary Radar Gauges) | 800 | ||
81 | 810 | MS | 810 | 6 | EA |
82 | 820 | ETHANOL | 820 | 4 | EA |
83 | 830 | For U/G horizontal product tanks | 830 | ||
84 | 840 | MS | 840 | 1 | EA |
85 | 850 | HSD | 850 | 1 | EA |
86 | 860 | HSD (OWN) | 860 | 1 | EA |
87 | 870 | ETHANOL | 870 | 1 | EA |
88 | 880 | BIO-DIESEL | 880 | 1 | EA |
89 | 890 | Supply of Non-contact type Radar level gauges with instrument accuracy of +/-3 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 890 | ||
90 | 900 | FIRE WATER | 900 | 3 | EA |
91 | 910 | SLUDGE | 910 | 1 | EA |
92 | 920 | Supply of Guided wave RADAR type level gauge with transmitter , instrument accuracy of +/- 3 mm or better, in built digital display, along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) as per specification. | 920 | ||
93 | 930 | For Additive Tanks | 930 | 2 | EA |
94 | 940 | Supply of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document. | 940 | ||
95 | 950 | With minimum 8 elements temperature sensor (for A/G vertical tanks) | 950 | ||
96 | 960 | For Cone Roof Vertical Tanks (Primary and Secondary Radar Gauges) | 960 | ||
97 | 970 | HSD | 970 | 3 | EA |
98 | 980 | BIO-DIESEL | 980 | 1 | EA |
99 | 990 | PCK | 990 | 2 | EA |
100 | 1000 | For Internal Floating Roof vertical tanks/Floating roof vertical tanks (Primary and Secondary Radar Gauges) | 1000 | ||
101 | 1010 | MS | 1010 | 3 | EA |
102 | 1020 | ETHANOL | 1020 | 2 | EA |
103 | 1030 | For U/G horizontal product tanks | 1030 | ||
104 | 1040 | MS | 1040 | 1 | EA |
105 | 1050 | HSD | 1050 | 1 | EA |
106 | 1060 | HSD (OWN) | 1060 | 1 | EA |
107 | 1070 | ETHANOL | 1070 | 1 | EA |
108 | 1080 | BIO-DIESEL | 1080 | 1 | EA |
109 | 1090 | Supply of Density probe along with accessories etc for density measurement of the product in product tanks complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 1090 | ||
110 | 1100 | For A/G vertical tanks - Three elements | 1100 | ||
111 | 1110 | For Cone Roof Vertical Tanks (Primary and Secondary Radar Gauges) | 1110 | ||
112 | 1120 | HSD | 1120 | 3 | EA |
113 | 1130 | BIO-DIESEL | 1130 | 1 | EA |
114 | 1140 | PCK | 1140 | 2 | EA |
115 | 1150 | For Internal Floating Roof vertical tanks/Floating roof vertical tanks (Primary and Secondary Radar Gauges) | 1150 | ||
116 | 1160 | MS | 1160 | 3 | EA |
117 | 1170 | ETHANOL | 1170 | 2 | EA |
118 | 1180 | For U/G horizontal product tanks-One element | 1180 | ||
119 | 1190 | MS | 1190 | 1 | EA |
120 | 1200 | HSD | 1200 | 1 | EA |
121 | 1210 | HSD (OWN) | 1210 | 1 | EA |
122 | 1220 | ETHANOL | 1220 | 1 | EA |
123 | 1230 | BIO-DIESEL | 1230 | 1 | EA |
124 | 1240 | Supply of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tank inventory data. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 1240 | ||
125 | 1250 | For A/G Vertical Product tanks - (Primary & Secondary Radar Gauges) | 1250 | 22 | EA |
126 | 1260 | For U/G Product tanks | 1260 | 5 | EA |
127 | 1270 | For water tanks | 1270 | 3 | EA |
128 | 1280 | For Sludge tank | 1280 | 1 | EA |
129 | 1290 | Supply of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc complete as per specification and tender document | 1290 | ||
130 | 1300 | For A/G Vertical Product tanks | 1300 | 11 | EA |
131 | 1310 | For U/G horizontal product tanks | 1310 | 5 | EA |
132 | 1320 | Supply of Auto Tank Gauging (ATG) probe combo with density measurement (Wireless or Wired) including necessary accessories as per Tender specifications. | 1320 | 1 | EA |
133 | 1330 | Supply of parallel redundant Communication Interface Units (CIU) including all accessories etc for tank farm management system complete as per specification and tender document. | 1330 | ||
134 | 1340 | For Primary Radar gauges installed on A/G vertical , under ground product tank, water tank ,slope ,additive & Sludge tank etc. | 1340 | 1 | SET |
135 | 1350 | For Secondary Radar Gauges installed on A/G product tanks | 1350 | 1 | SET |
136 | 1360 | Supply of 1 no. of Redundant TFMS Server (Form Factor:Rack ,Mountable in 19" rack ) along with 1 no. rack type (1U) ,one no. Min. 19" LED monitor with keyboard & mouse ,suitable for 19" mounting & 24x7 operation, Licensed OS (latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed software from Radar Gauge OEM etc complete as per specification and tender document. | 1360 | 1 | SET |
137 | 1370 | Supply of TFMS Workstation with minimum 27" LED colour monitor, keyboard, mouse, KVM Switch, Licensed OS(latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed client software from same Radar Gauge OEM etc complete as per specification and tender document. \nNote: CPU shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost. | 1370 | ||
138 | 1380 | 19" Rack type at Control Room, form factor - Rack, CPU height - 2U (Maximum) | 1380 | 1 | EA |
139 | 1390 | Push Buttons Outside Dyke Walls | 1390 | ||
140 | 1400 | Supply of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for remote opening and closing of ROSOVs from LPBS along with FLP double compression gland, Tag plates,TBs, mounting structure, accessories etc complete as per specifications and tender document. | 1400 | ||
141 | 1410 | For ROSOVs (A/G product tank's inlet, outlet and recirculation line) | 1410 | 28 | EA |
142 | 1420 | ESD PUSH BUTTON STATION | 1420 | ||
143 | 1430 | Supply of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document. | 1430 | ||
144 | 1440 | Local ESD Push Button Station ( Each Battery of TLF -1X2 no., TLF pump house - 1 no.) | 1440 | 3 | EA |
145 | 1450 | Plant ESD Push Button Station ( Each battery of TLF - 1X2 No.) | 1450 | 2 | EA |
146 | 1460 | Supply of ESD push button stations (for indoor application), mushroom head type with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document. (control room - 1 no., security room - 1 no., TM's cabin - 1 no.) | 1460 | 3 | EA |
147 | 1470 | Control Room equipments | 1470 | ||
148 | 1480 | Supply of redundant fault tolerant Integrated Distributed Control System (DCS) along with DCS Panels, Marshalling Panels, keypad cum contactless smart card reader with accessories, limit switches, Input Output modules, Power supply units, Relays with base, barriers, TBs, Redundant host communication ports, Serial Interface Modules, HART modules, other communication modules, HMI , wirings, glands, plugs, other modules/ hardware required for interfacing with all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document.\nNote: Any other hardware, software, OPC server, Historian Server, storage, firewall, functional control key board etc required as per tender specification and design requirements, the same to be provided by the vendor at no additional cost to IOCL. | 1480 | 1 | SET |
149 | 1490 | Supply of Complete Terminal Automation Software along with required licences, dongle/keys, GUI, SCADA etc meeting the complete functional and technical requirements of the tender document. \nVendor to provide required software, licences, dongle/keys, GUI, SCADA etc for TAS Management Server, Distributed Control System, Operator work stations, fire fighting OIC, Alarm display and annunciation OIC, Engineering Work Stations(for safety PLC & DCS), Web Server, OPC Server, Historian Server / work station, any other devices connected to Control & Management LAN of the integrated Distributed Control System complete as per specification and tender document.\nTAS software shall be interfaced with following but not limited to major sub-systems / equipments alongwith GUI development for monitoring, logging, reporting, controls & interlocks etc as per specification and tender document.\n- Safety PLC\n- TAS - Management Server\n- TLF Automation System (TT reporting, registration & entry system, TT Queuing, FAN generation, TT registration number reading system, Photo pass management system,TT crew authorization system, Bay allocation, Additive Dosing system, Ethanol blending System, Interface with TLF equipments like BCU, MFM, Barrier Gates, Bay Queue Display, Bay allocation Display, Invoice generated display, rack monitors, Proximity card readers etc)\n-Tank Wagon loading Automation system (Rake inventory System,Rake registration system, FAN generation, Tank wagon allocation, Interface with TWG equipments like BCU, MFM etc,SAP-TWG integation)\n-Tank Wagon unloading Automation system\n-Tank Lorry Decantation System\n-TT calibration System\n-Bio Diesel Blending system \n- ANPR and Face recognisation | 1490 | 1 | LS |
150 | 1500 | -- Valve Automation System (ROSOVs, MOVs, DBBV, MCS Interface, SOVs, etc)\n-Tank Farm Management System ( TFMS Server, Primary & Secondary Radar Gauging, AOPS, Level transmitters, Level Switch, Density probes, MSTW, CIU etc)\n- Pipeline/ Refinery PLC Interface, OMC PLC interface\n - MCC, Pump, Borewell, DG Sets, Air compressors, VFDs\n- PA paging Interface \n- HC Detection System Interface\n-FAS Interface, Fire Fighting System, HVLR, Fire Alarm System Interface, Fire Engines, DG Set, Jockey pumps, Foam pumps, CFFS, Sprinkler & Fixed foam pourer system etc\n- VRU Package Units\n- Effluent Treatment plant\n- CCTV systems\n- Access Control System\n- SKO Blue Dye Dosing System\n- ESD System, Emergency panel, Power ESD, Local ESD, Wailing sirens\n- Pressure Transmitters\n- UPS & Power distribution boards etc\n- Interface with IOCL SAP through firewall\n- Visitor Management Software for setup, configuration, operation, events, history and archiving, recording, printing etc. complete as per specification and tender document - Any other Third Party Interface/ devices as per scope of the work order etc\nNote: The offered software shall also includes fault detection module and Web Server software for remote over IOCL Intranet across India as detatiled in the tender document.\n\n\n\n | 1500 | ||
151 | 1510 | Supply of Redundant SIL 3 TUV/ EXIDA certified Safety PLC along with PLC Panels, Marshalling Panels, keypad cum contactless smart card reader with accessories, limit switches, Dual redundant Input Output modules, Power supply units, Relays with base, barriers, TBs, Dual Ethernet ports per processor, Serial Interface Modules, HMI , wirings, glands, plugs, other modules/ hardware required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document.\nNote: The offered safety PLC shall be of the same make family of the integrated Distributed Control System. | 1510 | 1 | SET |
152 | 1520 | Supply of redundant TAS Management Server (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LCD/LED monitor of minimum size of 19" suitable for 24x7 operation along with High availability redundancy software working on redundant (Primary and Secondary) hot standby mode , keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document.\n OR\nSupply of Dual Mode Redundant Grade with built in redundancy TAS Management Server (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LED monitor of minimum size of 19" suitable for 24x7 operation, keyboard drawer, optical mouse and combo 4 port KVM switch (if required), OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document. \n\nTAS Management Servers (TAS-MS) shall have either of the above mentioned configuration meeting the complete specification and tender requirements. \n\nIn addition, the TAS-MS shall be configured to have Zero Downtime to repair, Full data redundancy shall be provided using proven technology , it shall also provide port level redundancy.The system solution shall be capable of self fault detection and isolation, all necessary hardware/software configuration etc to achieve the same shall be included. | 1520 | 1 | LOT |
153 | 1530 | Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like keypad cum contactless smart card reader for front & back door seperately with accessories, limit switches, earthing arrangements, breaker, fuses, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments. | 1530 | ||
154 | 1540 | For mounting of TAS Management Servers along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, Ethernet switch, GSM modems, MCBs etc as per specification and tender document. | 1540 | 1 | EA |
155 | 1550 | For mounting of CCTV Servers, Analytics Servers, NAS/SAN along with associated rack mounted monitors & keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, MCBs etc as per specification and tender document. | 1550 | 2 | EA |
156 | 1560 | For mounting of Redundant ACS cum photopass management Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking components, MCBs etc as per specification and tender document. | 1560 | 1 | EA |
157 | 1570 | For mounting of Redundant TFMS Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, CIUs, MCBs etc as per specification and tender document. | 1570 | 1 | EA |
158 | 1580 | For mounting of Rack mounted Master Control Stations for MOVs & DBBVs along with power adaptors, MCBs, required accessories etc as per specification and tender document. | 1580 | 2 | EA |
159 | 1590 | For mounting of Rack mounted CPUs of Control room console workstation (Rack type) , one number 19" rack mounted monitor, rack mounted keyboard, mouse, KVM switches for connection of all CPUs along with power adaptors, MCBs, required accessories etc as per specification and tender document. | 1590 | 2 | EA |
160 | 1600 | For mounting of Network equipments along with power adaptors, MCBs, required accessories etc as per specification and tender document. | 1600 | 1 | EA |
161 | 1610 | Supply of Operator Interface Console Computer (OIC) with minimum 27" colour LED monitor,keyboard, mouse,KVM Switch, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. CPU shall be kept in Panel room in 42 U Rack. \nNote: CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost | 1610 | ||
162 | 1620 | 19" Rack mounted at Control Room, form factor - Rack , Max. 2U height ( 3 OICs, 1 for alarm Display, 1 for fire fighting System) | 1620 | 5 | EA |
163 | 1630 | Supply of Operator Interface Console Computer (OIC) minimum 27" colour LED monitor,keyboard, mouse, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. | 1630 | ||
164 | 1640 | Tower type in TM's Cabin + Pipeline Division control room | 1640 | 2 | EA |
165 | 1650 | Supply of Engineering Workstation (EWS) with minimum 27" colour LED monitor, keyboard, mouse, KVM Switch, Safety PLC & DCS software, HMI software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. (Locations: 1 no. in CR for both DCS and Safety PLC) \nNote: CPU shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost | 1650 | ||
166 | 1660 | 19" Rack mounted at Control Room, Form factor - Rack , Max. 2U height | 1660 | 1 | EA |
167 | 1670 | Supply of Tank Truck Entry System (TTES) Workstation with minimum 27" colour LED monitor, keyboard, mouse,KVM switch, software, SCADA, GUI, OS, Antivirus etc. complete as per specifications and tender document. \nNote: CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost | 1670 | ||
168 | 1680 | 19" Rack mounted at Control Room, Form factor - Rack , Max. 2U height | 1680 | 1 | EA |
169 | 1690 | Tower type in Customer service block (2 nos.) and Lock shed room (1 no.) | 1690 | 3 | EA |
170 | 1700 | Supply of minimum 19" colored LED monitor (19" Rack type at panel Room, form factor - Rack, height - 1U) with , KVM switch, Rack type keyboard, mouse etc located in Control Room complete as per specifications and Tender Document. (For CPUs of Console kept in panel room) | 1700 | 2 | EA |
171 | 1710 | Supply of Web Server (Rack type mountable in 19" rack ) , Rack type CPU - 2U Max. , LED monitor of minimum size of 27" suitable for 24x7 operation, keyboard, mouse, KVM Switch, web application software, SCADA, GUI, OS, Antivirus etc located in panel Room complete as per specifications and Tender Document. \nNote: CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost | 1710 | 1 | EA |
172 | 1720 | Supply of the NMS System covering Network Devices operational in Terminal Automation System. The Offered Network Management Solution (NMS) solution should support at least the following:\n• All the proposed NMS Components should be from single vendor. \n• NMS Software should support Graphical view up to port level for the all the devices.\nDiscovery of Network Elements.\n• Real time Traffic monitoring of Network Links and Devices with Historical reports for various periods.\n• Management of SNMPv1, SNMPv2, SNMPv3 & MIB etc.\n• Configuration of thresholds for Generating alarms.\n• Configuration of alarm actions (visual, audible, email, sms etc.) for each \nNetwork element.\n• Should be able to provide secured windows based consoles / secured web based consoles for accessibility to NMS.\n• Should have web browser interface with user name and Password Authentication.\n• Administrator/ Manager should have privilege to create/modify/delete user.\n• NMS should have support for SNMPv3 & IPv6, including dual-stack IPv4 & IPv6 to provide flexibility in protocol strategy and implementation.\n | 1720 | 1 | LS |
173 | 1730 | Supply of Terminal servers (rack mounted) with inbuilt/externally mounted lightening and Surge Protection Device Type (1+2) at all Serial ports, for interfacing and integration of field devices (Indoor & outdoor), LED Display unit for TT reporting,at Main Entry gate & Exit gate and TLF Entry gate for Bay allocation with TAS.In case the above listed equipments do not come with open communication protocol compatible to be directly interfaced with DCS Serial / MODBUS TCP IP module complete as per specification and tender document.\nNote: Terminal Servers to be configured in Dual Redundant mode. | 1730 | ||
174 | 1740 | 16 ports at Control Room/Customer service Room | 1740 | 2 | EA |
175 | 1750 | Supply of 24 ports Layer 3 Managed Ethernet Switches (10/100/1000 MBPS) with SFP, copper, fibre modules/ports along with accessories for connecting Plant management LAN equipments like CCTV System, TAS - MS Server/ Redundant OPC server, TFMS Server, TFMS work station, OICs, IOCL intranet for SAP connectivity through fire wall, Network printers, Access Control Server, Web Server Access over IOCL Intranet, connecting to OIC/ work stations etc which needs to be connected to both Plant Management LAN and Plant Control LAN for getting the entire GUIs of Complete Terminal Automation System and any other third party devices for interfacing with DCS etc.\nNote: \n1. Ethernet Switches to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs and any other equipment which are to be connected to above switch and the communication is through OFC cable. | 1750 | 2 | EA |
176 | 1760 | Supply of minimum 24 ports Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fibre modules, accessories for connecting equipments installed in Plant Control LAN like TAS- MS Servers, OICs, TTES cum TWES , EWS, OPC Servers, Fire fighting OICs, Alarm Display OIC, DCS, Safety PLC, inter connecting building work stations etc as per system architecture and design requirement complete as per specification and tender document.\nNote:\n1. The switches are to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs, and any other equipment which are to be connected to above switch and the communication is through OFC cable. | 1760 | 2 | EA |
177 | 1770 | Supply of Layer 2 Managed Ethernet Switches along with accessories for connecting BCU with TAS, equipments installed in Customer service room, Lock room, Security room, Terminal Manager room and other TAS equipments as per system architecture and design requirement complete as per specification and tender document.\nNote: \n1. Ethernet switches for BCU communication shall have suitable mounting arrangement to mount inside FLP JBs. \n2. The switches are to be configured in Dual Redundant mode.\n3. All OICs, Workstations, Servers other than that of CCTV, ACS & TFMS are to be connected to both plant management and control LAN so that all the GUIs can be seen in all the PCs irrespective of its nomenclature like TTES, OIC, EWS, TM PC etc.\n4. Printers to be connected to Plant Management LAN and to be configured to all PCs, Workstation, TTES etc so that printout command can be issued from any of the Machine. | 1770 | ||
178 | 1780 | For BCU integration at TLF (copper ports of 10/100/1000 MBPS)-( Minimum 8 nos. copper ports and 2 nos. optical ports) | 1780 | 8 | EA |
179 | 1790 | For BCU integration at TT Calibration shed-2 Nos (copper ports of 10/100/1000 MBPS)-(Minimum 4 nos. copper ports and 2 nos. optical ports) | 1790 | 2 | EA |
180 | 1800 | For connecting all MODBUS TCP IP devices ( any other devices) to DCS Ethernet port directly for integration (copper ports of 10/100/1000 MBPS)- to be located in Control Room ( Minimum 8 nos. copper ports and 2 nos. optical ports) | 1800 | 2 | EA |
181 | 1810 | At Lock Shed - copper ports of 10/100/1000 MBPS [control LAN - 2 nos. & Management LAN - 2 nos.] ( Minimum 8 nos. copper ports and 2 nos. optical ports) | 1810 | 4 | EA |
182 | 1820 | At Admin Building for TM cabin - copper ports of 10/100/1000 MBPS [control LAN - 2 nos., Management LAN - 2 nos., CCTV - 2 no.] (Minimum 8 nos. copper ports and 2 nos. optical ports) | 1820 | 6 | EA |
183 | 1830 | At Security Room - copper ports of 10/100/1000 MBPS [Management LAN - 2 nos.,CCTV - 2 no.] (Minimum 8 nos. copper ports and 2 nos. optical ports) | 1830 | 4 | EA |
184 | 1840 | At Driver rest room - copper ports of 10/100/1000 MBPS [Managent LAN - 2 nos.] (Minimum 4 nos. copper ports and 2 nos. optical ports) | 1840 | 2 | EA |
185 | 1850 | Supply of industrial grade redundant Serial to Ethernet converter of 8 port with mounting acessories etc complete in all respect as per specification and tender document. (Ports:- 6 Main + 2 Spare) | 1850 | ||
186 | 1860 | For MFM and other serial devices integration to DCS -TLF | 1860 | 4 | EA |
187 | 1870 | Supply of Wall mounted/wheel mounted Network Rack-minimum 19U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at Security Room, TM room, Invoice Room for TAS equipments | 1870 | 4 | EA |
188 | 1880 | Supply of Monochrome Laser Printer along with accessories for TAS and TFMS report printing in control room (2 nos.) and 2 nos. at security room complete as per specifications and tender document. | 1880 | 4 | EA |
189 | 1890 | Supply of heavy duty high speed laser printer and accessories for invoice printing in lock shed room, complete as per specifications and tender document. | 1890 | 2 | EA |
190 | 1900 | Supply of parallel redundant UPS of minimum capacity of 60 KVA or as per load calculation (whichever is higher) for entire TAS equipments and third party devices integrated with TAS and powered through TAS UPS with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type. | 1900 | 1 | SET |
191 | 1910 | Supply of UPS Power Distribution Panel along with keypad cum contactless smart card reader for front and rear gate sepearately with accessories for powering DCS Panel, Safety PLC Panel, TAS-MS, OIC, EWS, TFMS System, TTES, printers, Bay Instruments other control room equipments, Tank Farm Instruments, CCTV system, Fire Detection System, Access control system, Bay Queue Display boards, other display boards, ROSOV ESD port, header line instruments and any other TAS equipments where UPS power are required for smooth un-interrupted operation. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation, MCB etc are to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring with digital voltmeter & digital ammeter separately for UPS and Auxilliary supply for front and rear seperately etc as per specifications and tender document.\nNote: Minimum 20% spare power points to be made available for future use. | 1910 | 1 | LS |
192 | 1920 | Supply of Open desk operator consoles, chairs, printer tables etc complete as per specification and tender document. | 1920 | ||
193 | 1930 | Open desk operator consoles for mounting of monitor in two tiers , 2 nos. of key boards, 2 nos. of mouse, accesscories e.g. Telephone,VHF sets, Master control station for PA paging,storage etc complete as per specification and tender document.\n(For mounting of 3 nos. OICs monitor, 1 no. Alarm Display OIC monitor, 1 no. Fire fighting OIC monitor, 1 no. TTES monitor , 1 TFMS workstation monitor, 1 no. CCTV client monitor,1 no. EWS monitor,1 Web server, storage etc.) | 1930 | 7 | EA |
194 | 1940 | Chairs (Godrej interio Ace Mid back high performance chair) | 1940 | 7 | EA |
195 | 1950 | Standard Printer Tables of Godrej or equivalent make (2 nos. at security gate, 1 no. in Lock shed room, 1 no. in security room for visitor management) | 1950 | 4 | EA |
196 | 1960 | Standard Computer Table of Godrej or equivalent make for installation of CCTV client , ACS client in security room (2 nos.),Photo pass management PC (1 No.), TTES in Customer service room (2 nos.) and TTES in lock shed room (1 no.) | 1960 | 6 | EA |
197 | 1970 | Supply of IP based Redundant GSM modem suitable for 24x7 operation along with accessories for auto SMS as per specification and tender document. | 1970 | 1 | SET |
198 | 1980 | Hydrocarbon Detection system | 1980 | ||
199 | 1990 | Supply of Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon vapour detectors along with calibration kit, accessories and structural supports, Aluminium canopy/sunshade etc as per specification and tender document. | 1990 | ||
200 | 2000 | Point type Infrared detector\n(Indicative location: Each tank dyke sump pit inside dyke wall -7 nos., Near ROSOVs of MS tanks:-3 Nos., Ethanol tanks- 2 nos.,Tx Tanks - 2 nos., TLF pump seal (MS+Ethanol) - 6 Nos,Sludge pump seal-3 No.,Tx Pump-1 No., Pump house drain pit - 1 no.; Vapour recovery system drain pit - 1 no.,ETP-1 No.,PL sump tank -1 No., PL Near SLB/SRB - 1 No.,PL Delivery Manifold - 1 No., PL Booster Manifold - 1 No.,PL main line Pump seal - 3 No.) | 2000 | 34 | EA |
201 | 2010 | Open path type Infrared detector (10-60 m) along with alignment telescope, configuration & Testing kit etc (Tentative location: MS tanks - 8 Nos. , Tx Tanks - 3 nos. & Ethanol tanks covering ROSOVs - 3 nos., Main Line & Booster Pump Shed - 2 Nos.) | 2010 | 16 | EA |
202 | 2020 | Open path type Infrared detector (10-90 m) along with alignment telescope, configuration & testing kit etc (Tentative location: TLF PH-3 Nos) | 2020 | 3 | EA |
203 | 2030 | Supply of Flameproof cum weather proof (IP 66 or better) min SIL 2 certified UV/IR Flame detectors along with mounting arrangments, accessories and structural supports, Aluminium canopy/sunshade etc as per specification and tender document. | 2030 | ||
204 | 2040 | Main Line Pump Shed - 6 Nos., Booster Pump Shed - 2 Nos. | 2040 | 8 | EA |
205 | 2050 | Supply of weather proof and Explosion proof Hooter cum beacons/ flash light along with accessories and structural supports as per specification.( Tentative location : Each product tank dyke (MS)-1 No.,(Ethanol & Tx)-1 No., Pump House (TLF) - 1 No.,ETP-1 No.,VRU-1 No., PL Station - 1 No.) | 2050 | 6 | EA |
206 | 2060 | Supply of one no. of Portable Hydrocarbon vapour detector along with accessories complete as per specification and tender document. | 2060 | 1 | EA |
207 | 2070 | Automatic Fire Detection and Alarm System | 2070 | ||
208 | 2080 | Supply of microprocessor based automatic Fire Alarm Panel along with required Software, and hardware like Control module, monitor module, fault isolation module (in built/ External), mounting structure support etc complete as per standard design engineering, specification and tender document.\nLocation : Control Room | 2080 | 1 | EA |
209 | 2090 | Supply of Repeater Panel along with software, hardware, mounting accessories etc required as per standard design Engineer, specifications and tender document complete in all respect. \n | 2090 | ||
210 | 2100 | Security Gate - 1 no., Fire Pump House - 1 no., Pipeline control room - 1 no. | 2100 | 3 | EA |
211 | 2110 | Supply of addressable type detectors along with accessories, fault isolation module (Inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 2110 | ||
212 | 2120 | Combination/Multi-sensor Detector | 2120 | 585 | EA |
213 | 2130 | Rate of Rise Heat Detector | 2130 | 11 | EA |
214 | 2140 | IS detector | 2140 | 22 | EA |
215 | 2150 | Hydrogen Detector | 2150 | 4 | EA |
216 | 2160 | Supply of Manual Call Point along with accessories, fault isolation module (Inbuilt/ External) and structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 2160 | ||
217 | 2170 | Ex-proof and weather proof MCP | 2170 | 18 | EA |
218 | 2180 | Weather proof MCP | 2180 | 23 | EA |
219 | 2190 | Supply of Hooter along with accessories, fault isolation module (inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 2190 | ||
220 | 2200 | Weather proof Hooter cum Beacon | 2200 | 21 | EA |
221 | 2210 | Supply of Response Indicator along with accessories, mounting structure etc required as per standard design engineering, specification and tender document complete in all respect. | 2210 | 218 | EA |
222 | 2220 | Access Control System | 2220 | ||
223 | 2230 | Supply of half man height bi-directional turnstile (tripod) with controller along with accessories, mounting structure, pressure sensor etc required as per standard design engineering, specification and tender document complete in all respect. | 2230 | ||
224 | 2240 | License area entry & exit gate (Marketing)- 2 nos. ,License area entry & exit gate (LPG)- 2 nos. , Entry/Exit to tank farm area - 4 nos. | 2240 | 8 | EA |
225 | 2250 | Supply of half man height dual lane Uni-directional turnstile (tripod) with controller along with accessories, mounting structure, pressure sensor etc required as per standard design engineering, specification and tender document complete in all respect. | 2250 | ||
226 | 2260 | At security entry gate/exit gate | 2260 | 3 | SET |
227 | 2270 | Supply of Retractable Dual Lane Flap barrier with controller along with accessories, mounting structure, pressure sensor etc required as per standard design, engineering, specification and tender document complete in all respect. | 2270 | ||
228 | 2280 | Admin building entry/exit | 2280 | 2 | SET |
229 | 2290 | Supply of face detection cum fingerprint cum contactless type smart card reader with controller along with electromagnetic door lock of 600 lb for single door/double door, 2 nos. of door position magnetic contact with buzzer etc as per specifications and tender document.\nNote: EM locks to be provided at no additional cost to IOCL. | 2290 | ||
230 | 2300 | Console room entry/exit door (Mkt+ LPG+Pipeline) - 10 nos., Panel room entry/exit door (Mkt+ LPG+Pipeline)- 10 nos. ,Console Room Exit Gate (Emergency)-1x2 no | 2300 | 22 | EA |
231 | 2310 | Supply of Biometric fingerprint cum contactless type smart card reader along with accessories, software , programming kit etc required as per standard design engineering, specification and tender document complete in all respect. | 2310 | ||
232 | 2320 | Location:-(Turnstile:- Security entry/exit gate (Bi-directional)- Mkt - : 6x2 nos,License area (TLF) entry/exit gates (Bi-directional) - Mkt - : 2x2 nos,Entry/exit to tank farm area (Bi-directional)- Mkt- : 4x2 nos,Panel room Exit Gate (Mkt + Pipeline+LPG)-1x2 no,TLF/Tank Farm Area Entry/Exit (Bi-directional) -LPG - 2x2 nos,Flap barrier - 4x2nos.-Admin Building.) | 2320 | 38 | EA |
233 | 2330 | Supply of 2 No. Door Frame Metal Detector, 4 nos. hand held metal detector along with accessories, mounting structure etc complete as per specification and tender document. | 2330 | 1 | SET |
234 | 2340 | Supply of 2" size SS 304 guiding rail along with mounting accessories complete as per specification and tender document near turnstile/ tripod/flap barrier etc to prevent un-authorised movement. | 2340 | 100 | M |
235 | 2350 | Supply and configuration of Proximity smart access cards as per the specification and tender document. | 2350 | 500 | EA |
236 | 2360 | Supply of Redudnant ACS Server for photo pass management & visitor management (19" Rack type at panel Room, form factor - Rack, CPU height - 2U) with minimum 19" colored LED monitor, KVM switch, keyboard, mouse, OS, Antivirus etc located in Control Room complete as per specifications and Tender Document. | 2360 | 1 | SET |
237 | 2370 | Supply of Access Control cum photopass management System Software for setup, configuration, operation, events, history and archiving, alarm monitoring, recording, printing, time and attendance etc. complete as per specification and tender document including hardwired interface with TAS for ESD input. | 2370 | 1 | LS |
238 | 2380 | Supply of Client workstation of ACS cum Photopass management with minimum 27" coloured monitor,keyboard, mouse,KVM switch (extender/reciver) for Rack CPU, OS, Antivirus, HD coloured video camera (for taking visitors photograph) etc for ID badging & issuing of Visitor pass/Photo pass at security Room & other etc. complete as per specifications. | 2380 | ||
239 | 2390 | Rack Type - CPU in panel room with KVM sitch; Keyboard, mouse along with monitor etc. to be installed in security room for visitor pass | 2390 | 1 | EA |
240 | 2400 | Tower Type in Photopass room for TT crew/Contractor etc. | 2400 | 1 | EA |
241 | 2410 | Supply of Laser printer (Monochrome) for Visitor pass printing having flexibility to print on A4, A5, A6 paper complete as per specification and tender document. | 2410 | 1 | EA |
242 | 2420 | Supply of Colour photo pass printer along with integrated/seperate scanner for photo pass printing as per specification and tender document. | 2420 | 2 | EA |
243 | 2430 | Supply of PVC cards for printing of photo pass as per specification and tender document. | 2430 | 1000 | EA |
244 | 2440 | IP BASED CCTV SURVEILLANCE SYSTEM | 2440 | ||
245 | 2450 | Supply of HD IP Fixed Dome camera with IR and MFZ lens (2MP) along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 2450 | 10 | EA |
246 | 2460 | Supply of HD IP PTZ Camera (2MP) along with power supply unit (POE based) with POE injector (industrial grade),with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 2460 | 31 | EA |
247 | 2470 | Supply of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 2470 | 9 | EA |
248 | 2480 | Supply of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 2480 | 58 | EA |
249 | 2490 | Supply of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 2490 | 10 | EA |
250 | 2500 | Supply of HD varifocal IP Fixed Outdoor Box Camera (2MP) along with power supply unit (POE based) , with inbuilt/external surge protection unit and mounting accessories per the tender specifications and instructions of Engineer in charge | 2500 | 1 | EA |
251 | 2510 | Supply of 4 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 4 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector (Type 1+2) at the input power supply as per specifications and Tender Document. | 2510 | 60 | EA |
252 | 2520 | Supply of outdoor Explosion proof cum weatherproof housing (IP 65 or better) suitable for installing Layer 2 switch, PSU, LIU and adaptor for Ethernet switch/media convertor, surge protectors and other accessories of CCTV cameras. Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, Ethernet cable with RJ45 connector etc complete in all respect for functioning of CCTV camera.The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc as per specifications and Tender Document. | 2520 | 60 | EA |
253 | 2530 | Design, fabrication and supply of Heavy Duty self supported Hot Dip Galvanized Poles for mounting of CCTV cameras along with civil foundation along with GI foundation bolt, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, SS nut & bolts for fixing camera and other accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document)\nNote: In case pole do not have ladder arrangment for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL. | 2530 | ||
254 | 2540 | 10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender | 2540 | 8 | EA |
255 | 2550 | 12 M pole with cantilever arrangement | 2550 | 13 | EA |
256 | 2560 | 15 M pole with cantilever arrangement | 2560 | 2 | EA |
257 | 2570 | 8 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender | 2570 | 50 | EA |
258 | 2580 | 4/6 M pole with Accessories as per specification of Tender | 2580 | 9 | EA |
259 | 2590 | Supply of rack mounted CCTV Server (s) along with rack type monitor, optical mouse and combo 4 port KVM switch, OS, Antivirus, LIU etc complete as per specifications and Tender Document. \nNote: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL. | 2590 | 1 | LS |
260 | 2600 | Supply of Network Attached Storage ( NAS ) / Storage Attached Network (SAN) for storing recorded video for a minimum period 90 days @ 15 FPS at full resolution & highest Video quality of all cameras (Continuous recording) complete as per specifications and Tender Document. | 2600 | 500 | TB |
261 | 2610 | Supply of CCTV client work station along with client software & licenses, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document.\n\nNote: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors . Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.Marketing CPU for control room & security room shall be kept in Panel room in 42 U Rack. KVM extender & reciever for these CPU is to be supplied at no additional cost. | 2610 | ||
262 | 2620 | Rack type (2 U) with minimum 27" colored LED monitor :- Control Room - 1 no. ,Security Room - 1no.(CPU to be kept in Mkt. panel room) | 2620 | 2 | EA |
263 | 2630 | Tower type without Monitor :- Mkt. TM room - 1 No. , Pipeline TM room - 1 No., Pipeline CR room - 1 No. | 2630 | 3 | EA |
264 | 2640 | Design & Supply of video wall along with required controller & complete accecories , cables etc , mounting arrangement from wall/ceiling for fire fighting cum critical Alarm display & annuniciation cum CCTV application complete as per specifications and tender document. \nIn control room:-Windows for all cameras should be available on single screen of 300-400 cm2 for min. 150 no. CCTV camera.\n\nNote: Two Number (min. 55” each or meeting size of video wall) for Alarm LED display and Fire fighting display along with one no. of hooter with provision of dual tone sound,ack push button & accessories. | 2640 | 6 | EA |
265 | 2650 | Design & Supply of video wall along with controller & complete accecories , cables etc. for CCTV complete as per specifications and tender document. In location in charge room:-viewing window size should be preferably be between 250-300 cm2 (in two pages) for CCTV camera. | 2650 | 2 | EA |
266 | 2660 | Design & Supply of video wall along with controller & complete accecories , cables etc. for CCTV complete as per specifications and tender document. \nIn security cabin:-viewing window size should be preferably be between min. 150-200 cm2 ( in two pages) for CCTV camera. | 2660 | 2 | EA |
267 | 2670 | Supply of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. \nNote- The switches are required to be configured in dual redundant mode \n | 2670 | 2 | EA |
268 | 2680 | Supply of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 5 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher. | 2680 | 1 | LS |
269 | 2690 | Supply of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document. | 2690 | 1 | LS |
270 | 2700 | Supply of 350 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge. | 2700 | 58 | EA |
271 | 2710 | Supply of IP Fixed Bullet cameras with IR MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.(TT Reporting :-2+TTEntry/Exit:-2+Driver Entry/Exit-2,Helper Entry/Exit-2, Photo Pass issuance:- 2) | 2710 | 10 | EA |
272 | 2720 | Miscellaneous | 2720 | ||
273 | 2730 | Supply of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, isolation valve, Aluminium canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated else where in tender)\nNote:1. Pressure transmitter at suction shall have range from -1 Kg/cm2.\n2. Underground tank shall have PT in Pump discharge end only. | 2730 | ||
274 | 2740 | TLF pump Suction end | 2740 | 11 | EA |
275 | 2750 | TLF pumps Discharge end | 2750 | 11 | EA |
276 | 2760 | MS, HSD, Transmix, Ethanol Tanks Sprinkler & Foam Line | 2760 | 24 | EA |
277 | 2770 | Fire Hydrant lines (Fire Hydrant Header-2+Fire Hydrant line-2+Foam Pump-2) | 2770 | 6 | EA |
278 | 2780 | Sludge/Stripping Pumps suction end---Remote Seal Type | 2780 | 6 | EA |
279 | 2790 | Sludge/Stripping Pumps discharge end---Remote Seal Type | 2790 | 6 | EA |
280 | 2800 | Underground tank's pump discharge end | 2800 | 6 | EA |
281 | 2810 | Supply of flameproof cum weather proof to IP 65 or better SIL 2 Smart Differential pressure transmitter with in built display, SS 3 way manifold, Aluminium canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated else where in tender) | 2810 | ||
282 | 2820 | Across TLF pump Strainers | 2820 | 11 | EA |
283 | 2830 | Across Sludge/Stripping Pumps Strainers---Remote Seal Type | 2830 | 6 | EA |
284 | 2840 | Decentation line | 2840 | 2 | EA |
285 | 2850 | Supply of flameproof cum weather proof to IP 65 or better bi-colour magnetic flap type level gauge (side mounted) along with level transmitter with installed accuracy +/- 6 mm or better along with mounting accessories, complete as per specification and tender document. | 2850 | ||
286 | 2860 | Foam (Daughter+Mother) Tanks for HVLR | 2860 | 10 | EA |
287 | 2870 | Fire Engine Service tanks | 2870 | 6 | EA |
288 | 2880 | DG Set Service Tanks | 2880 | 3 | EA |
289 | 2890 | Supply of Level switch ( Magnetic Float / displacer type ) for low and high level alarm along with mounting accessories etc as per specifications | 2890 | ||
290 | 2900 | Fire water Sump | 2900 | 1 | EA |
291 | 2910 | TT calibration sump | 2910 | 1 | EA |
292 | 2920 | Treater water Tank + Service water | 2920 | 2 | EA |
293 | 2930 | Raw water sump | 2930 | 1 | EA |
294 | 2940 | Supply of Wailing siren along with controller with a provision to operate locally as well as from control room, mounting accessories etc complete as per specification and tender document. | 2940 | 1 | EA |
295 | 2950 | Supply of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Control Room - 12 nos., S&D room-4 Nos., Invoice room - 4 nos. & Security Room - 4 nos.) | 2950 | 1 | LS |
296 | 2960 | Supply of Ex-proof and weather proof Hooter cum Beacons along with accessories, mounting structure etc complete as per specification and tender document for audio visual alarm at field in case the MOVs installed at tank dyke drain and tank water draw off line is not fully closed. \nLocation : Near each tank dyke and to be installed outside dyke. | 2960 | 7 | EA |
297 | 2970 | Supply of solenoid valves (SOV) of 25/32/50/65 NB (as per line size) along with one no. of isolation by pass valve to bypass the SOV with associated piping, mounting accessories etc complete as per specification and tender document. \nNote: SOV need to be supplied factory fitted along with baypass valve and both side flanged option.For Ethanol tank HVLRs SOV is not required. | 2970 | ||
298 | 2980 | At the inlet of DG set Service tanks | 2980 | 3 | EA |
299 | 2990 | At the inlet of Fire Engine Service tanks | 2990 | 6 | EA |
300 | 3000 | At the inlet of HVLR tanks | 3000 | 6 | EA |
301 | 3010 | Supply of MCT block for entire Automation cable entry to Control Room, Admin Building, Invoice Room, Security Room, Customer service room, Driver's Rest Room with minimum 30% spare MCT blocks for future cable entry along with frame and mounting accessories complete as per specification and tender document. | 3010 | 1 | LS |
302 | 3020 | Supply of external surge & Lightening protection devices of suitable connector and type along with accessories complete as per specification and tender document at following places. | 3020 | ||
303 | 3030 | SPD (Type 2 / IC category C1,C2,C3,D1) - Serial port of MCS (RJ45 type) & Terminal Server | 3030 | 42 | EA |
304 | 3040 | Type 1 SPD - Earth pit | 3040 | 10 | EA |
305 | 3050 | Supply of Magentic Flow Meter in water line in outlet of borewell along with two number of SS ball valve along with bypass valve and associated piping as tender specification and mounting accessories complete as per specification and tender document. | 3050 | 1 | EA |
306 | 3060 | Supply of Turbine Flow Meter (40/50 MM) with pulse transmitter and field totalizer unit in n Flameproof and Weather Proof (Min. IP 65) enclosure along with two number of SS ball valve,strainer cum aireliminter (50 mm) and associated piping as tender specification and mounting accessories complete as per specification and tender document. \nNote: For HSD Meaurement to pipeline division. | 3060 | 2 | EA |
307 | 3070 | Cabling, JB, Earthing: | 3070 | ||
308 | 3080 | Note: Supply of cables shall be along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), LAN face plates, conduits, structural steel for mounting of equipments, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc | 3080 | ||
309 | 3090 | Supply of FRLS Armoured Copper Power cable as per tender specifications. | 3090 | ||
310 | 3100 | 3C x 2.5 sqmm | 3100 | 12600 | M |
311 | 3110 | 4C x 2.5 sqmm | 3110 | 2200 | M |
312 | 3120 | 8C x 2.5 sqmm | 3120 | 4800 | M |
313 | 3130 | 10C x 2.5 sqmm | 3130 | 3800 | M |
314 | 3140 | 12C x 2.5 sqmm | 3140 | 2200 | M |
315 | 3150 | 24C x 2.5 sqmm | 3150 | 3600 | M |
316 | 3160 | 3C x 4 sqmm | 3160 | 6000 | M |
317 | 3170 | 4C x 4 sqmm | 3170 | 2400 | M |
318 | 3180 | 4C x 6 sqmm | 3180 | 100 | M |
319 | 3190 | 4C x 10 sqmm | 3190 | 100 | M |
320 | 3200 | Supply of FRLS Armoured Aluminium Power cable as per tender specifications. | 3200 | ||
321 | 3210 | 3.5C x 120 sqmm | 3210 | 600 | M |
322 | 3220 | Supply of FRLS Armoured Copper Control cable as per tender specifications. | 3220 | ||
323 | 3230 | 2C x 1.5 sqmm | 3230 | 12000 | M |
324 | 3240 | 3C x 1.5 sqmm | 3240 | 1000 | M |
325 | 3250 | 4C x 1.5 sqmm | 3250 | 8000 | M |
326 | 3260 | 6C x 1.5 sqmm | 3260 | 3000 | M |
327 | 3270 | 8C x 1.5 sqmm | 3270 | 3000 | M |
328 | 3280 | 10C x 1.5 sqmm | 3280 | 2000 | M |
329 | 3290 | 12C x 1.5 sqmm | 3290 | 5000 | M |
330 | 3300 | 16C x 1.5 sqmm | 3300 | 1000 | M |
331 | 3310 | 18C x 1.5 sqmm | 3310 | 4000 | M |
332 | 3320 | 20C x 1.5 sqmm | 3320 | 1000 | M |
333 | 3330 | 24C x 1.5 sqmm | 3330 | 3500 | M |
334 | 3340 | 32C x 1.5 sqmm | 3340 | 1000 | M |
335 | 3350 | 36C x 1.5 sqmm | 3350 | 1200 | M |
336 | 3360 | 48C x 1.5 sqmm | 3360 | 5500 | M |
337 | 3370 | Supply of FRLS Armoured Copper Signal cable as per tender specifications. | 3370 | ||
338 | 3380 | 1P x 1.5 sqmm | 3380 | 12000 | M |
339 | 3390 | 2P x 1.5 sqmm | 3390 | 8500 | M |
340 | 3400 | 3P x 1.5 sqmm | 3400 | 2400 | M |
341 | 3410 | 4P x 1.5 sqmm | 3410 | 900 | M |
342 | 3420 | 6P x 1.5 sqmm | 3420 | 2500 | M |
343 | 3430 | 8P x 1.5 sqmm | 3430 | 1500 | M |
344 | 3440 | 10P x 1.5 sqmm | 3440 | 1000 | M |
345 | 3450 | 12P x 1.5 sqmm | 3450 | 5500 | M |
346 | 3460 | 16P x 1.5 sqmm | 3460 | 1200 | M |
347 | 3470 | 18P x 1.5 sqmm | 3470 | 1500 | M |
348 | 3480 | 1T x 1.5 sqmm | 3480 | 1200 | M |
349 | 3490 | 8T x 1.5 sqmm | 3490 | 2500 | M |
350 | 3500 | Supply of FS Armoured Copper Power cable as per tender specifications. | 3500 | ||
351 | 3510 | 3C x 2.5 sqmm | 3510 | 8000 | M |
352 | 3520 | 3C x 4 sqmm | 3520 | 1800 | M |
353 | 3530 | 4C x 2.5 sqmm | 3530 | 1200 | M |
354 | 3540 | 4C x 4 sqmm | 3540 | 1400 | M |
355 | 3550 | Supply of FS Armoured Copper Control cable as per tender specifications. | 3550 | ||
356 | 3560 | 2C x 1.5 sqmm | 3560 | 5800 | M |
357 | 3570 | 3C x 1.5 sqmm | 3570 | 100 | M |
358 | 3580 | 4C x 1.5 sqmm | 3580 | 2000 | M |
359 | 3590 | 6C x 1.5 sqmm | 3590 | 4200 | M |
360 | 3600 | 8C x 1.5 sqmm | 3600 | 4600 | M |
361 | 3610 | 10C x 1.5 sqmm | 3610 | 1000 | M |
362 | 3620 | 12C x 1.5 sqmm | 3620 | 2400 | M |
363 | 3630 | 18C x 1.5 sqmm | 3630 | 1000 | M |
364 | 3640 | 24C x 1.5 sqmm | 3640 | 3000 | M |
365 | 3650 | 32C x 1.5 sqmm | 3650 | 1500 | M |
366 | 3660 | 36C x 1.5 sqmm | 3660 | 1000 | M |
367 | 3670 | 48C x 1.5 sqmm | 3670 | 2500 | M |
368 | 3680 | Supply of FS Armoured Copper Signal cable as per tender specifications. | 3680 | ||
369 | 3690 | 1P x 1.5 sqmm | 3690 | 7000 | M |
370 | 3700 | 2P x 1.5 sqmm | 3700 | 5800 | M |
371 | 3710 | 3P x 1.5 sqmm | 3710 | 3200 | M |
372 | 3720 | 4P x 1.5 sqmm | 3720 | 5000 | M |
373 | 3730 | 1T x 1.5 sqmm | 3730 | 3200 | M |
374 | 3740 | Supply of 6 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge. | 3740 | 7000 | M |
375 | 3750 | Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge. | 3750 | 4000 | M |
376 | 3760 | Supply of Pre fab CAT 6 Ethernet un-armoured cable as per tender specifications and instructions of Engineer in charge. | 3760 | ||
377 | 3770 | 5/10 m | 3770 | 150 | EA |
378 | 3780 | 15 m | 3780 | 50 | EA |
379 | 3790 | 20 m | 3790 | 40 | EA |
380 | 3800 | 25 m | 3800 | 25 | EA |
381 | 3810 | 30 m | 3810 | 25 | EA |
382 | 3820 | Supply of 1C x 6 Sq. mm FRLS Flexible copper insulated green wire for earthing instruments and junction boxes etc complete as per specification and tender document | 3820 | 25000 | M |
383 | 3830 | Supply of GI strip ( 50mm X 6mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. | 3830 | 4000 | M |
384 | 3840 | Supply of GI strip ( 25mm X 3mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. | 3840 | 2000 | M |
385 | 3850 | Supply of anodized Aluminium perforated cable trays (2.5mm Thick), tray covers (1.5mm Thick ) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents. | 3850 | ||
386 | 3860 | 50 mm | 3860 | 8000 | M |
387 | 3870 | 100 mm | 3870 | 6500 | M |
388 | 3880 | 150 mm | 3880 | 4500 | M |
389 | 3890 | 300 mm | 3890 | 4000 | M |
390 | 3900 | 600 mm | 3900 | 1000 | M |
391 | 3910 | Supply of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents. | 3910 | ||
392 | 3920 | 24 ways JB | 3920 | 30 | EA |
393 | 3930 | 18 ways JB | 3930 | 35 | EA |
394 | 3940 | 12 ways JB | 3940 | 40 | EA |
395 | 3950 | 8 ways JB | 3950 | 60 | EA |
396 | 3960 | 6 ways JB | 3960 | 60 | EA |
397 | 3970 | 4 ways JB | 3970 | 60 | EA |
398 | 3980 | Supply of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge. | 3980 | 1500 | M |
399 | 3990 | Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc | 3990 | 30 | TO |
400 | 4000 | Earth Pit | 4000 | ||
401 | 4010 | Supply of Maintenance Free CPRI approved Earth pit ( Ashlok /Equivalent make ) as per IS : 3043 with 100 mm dia of minimum 3mtr length safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Procedure recommended by chemical earth supplier and IS code to be finally adopted. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation.\nAll Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification) | 4010 | ||
402 | 4020 | TLF gantry | 4020 | 2 | EA |
403 | 4030 | TT earthing | 4030 | 6 | EA |
404 | 4040 | Control room | 4040 | 6 | EA |
405 | 4050 | Tank farm | 4050 | 10 | EA |
406 | 4060 | Pump house | 4060 | 4 | EA |
407 | 4070 | CCTV | 4070 | 16 | EA |
408 | 4080 | SUB TOTAL (I) - SUPPLY COMPONENTS (excluding GST) | 4080 | ||
409 | 4090 | SERVICE COMPONENTS | 4090 | ||
410 | 4100 | TANK LORRY FILLING | 4100 | ||
411 | 4110 | Installation, integration, testing and commissioning of Microprocessor based Coriolis mass flow meter for white oil application along with display unit and mounting accessories with adjustable screw support,bellow for vibrations etc complete as per specifications and tender document for loading of following main products \nNote: In case MFM is not having inbuilt ASTM table, vendor has to supply Flow Computers along with accessories as per tender document at no additional cost to IOCL. | 4110 | ||
412 | 4120 | MS (for line size of 100 mm ) | 4120 | 8 | EA |
413 | 4130 | HSD (for line size of 100 mm ) | 4130 | 12 | EA |
414 | 4140 | Water (Master MFM for TT calibration) for line size 50 mm along with structural support and required accessories for mounting | 4140 | 2 | EA |
415 | 4150 | Installation, integration, testing and commissioning of Strainer cum Air eliminator with differential pressure transmitter with display unit & keyboard across the Strainer along with accessories, SS tubing, needle valves etc complete as per specifications and tender document. | 4150 | ||
416 | 4160 | For product line size 100 mm - TLF | 4160 | 20 | EA |
417 | 4170 | For Water Line size 50 mm - TT calibration (along with structural support and required accessories) | 4170 | 2 | EA |
418 | 4180 | Installation, integration, testing and commissioning of Multistage Piston type Digital Control Valve (DCV) along with TRV with two nos. isolation valves at inlet and outlet of TRV with associated piping , secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete as per specifications and tender document. | 4180 | ||
419 | 4190 | For product line size 100 mm - TLF | 4190 | 20 | EA |
420 | 4200 | For Water Line size 50 mm - TT calibration along with vacuum breaker & isolation ball valve mounted on a spool piece & mounting accessories so that the entire water after DCV is drained into the TT after completion of each batch during TT calibration. | 4200 | 2 | EA |
421 | 4210 | Installation, integration, testing and commissioning of piston type, hydraulically operated ON-OFF Valve along with accessories, secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning ,tubing arrangement as per installation drawing etc for line size 100 mm complete as per specifications and tender document. | 4210 | 1 | EA |
422 | 4220 | Installation, integration, testing and commissioning of Triple Offset Butterfly valve with electrical/electro-hydraulic fail safe actuator ON-OFF along with accessories as per installation drawing etc for line size 100 mm complete as per specifications and tender document. | 4220 | 20 | EA |
423 | 4230 | Installation, integration, testing and commissioning of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. isolation ball valve, Aluminium canopy/sunshade with mounting accessories etc on the TLF metering skid complete as per specifications and tender document. \n(Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2) | 4230 | 26 | EA |
424 | 4240 | Installation, integration, testing and commissioning of flameproof cum weather proof, Temperature transmitter along with display unit and keypad, RTD, Thermo well, mounting accessories etc complete as per specifications and tender document. \n(Mounting at each TLF loading point on main product for line size 100 mm) | 4240 | 20 | EA |
425 | 4250 | Installation, integration, testing and commissioning of online proving valves manifold comprising of 1no. manual operated DBBV without actuator and 2 nos. of 100 NB, full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF MFM complete as per specifications and tender documents. | 4250 | 20 | SET |
426 | 4260 | Installation, testing and commissioning of bottom loading arm of size 100 mm NB along with 1 no. full bore isolation ball valve (100 mm), API Coupler, break away coupler, parking stand with compatible API adaptor, Ex-proof/intrinsic safe position sensor for parking stand, associated piping for connecting loading arm with the metering skid , mounting structure etc complete as per specifications and tender document. \nApplication: MS, HSD, MS+ETHANOL | 4260 | 20 | EA |
427 | 4270 | Installation, testing and commissioning of vapour recovery arm of size 80 mm NB having 3” (80 NB) with poppeted vapour coupler, break away coupler, NRV, flame arrestor, reducers, mounting structures, parking stand with compatible API adaptor, associated accessories, mounting structure etc complete as per specifications and tender document.\nApplication : MS | 4270 | 8 | EA |
428 | 4280 | Installation, testing and commissioning of Ex-proof Rack Monitors for TT overfill protection system along with accessories like 10 pin gantry plug, ATC copper coiled cable of minimum 8m as per API RP1004 including required support for mounting of the Rack Monitor and gantry plug, etc complete as per specifications and tender document.\nNote: In addition to above, minimum 2 nos. portable Rack Monitor along with accessories and 2 nos. lockable bypass switch are to be provided against total supply of Rack Monitor. | 4280 | 12 | EA |
429 | 4290 | Installation, integration, testing and commissioning of Resistance - Capacitance type Tank Truck grounding unit along with accessories like 3 nos. of heavy duty flexible coiled cables with high quality rugged, heavy duty SS/ brass grounding socket, FLP double compression glands, Ex-Plug, mounting structure etc, complete as per specification and tender documents.\n(2 nos. of coiled cable with socket for TT earthing relay interlocks and 1 no. for separate earthing of TT) | 4290 | 12 | EA |
430 | 4300 | Installation, integration, testing and commissioning of Ex-proof field mounted Remote Interaction Terminal (RIT) along with FLP double compression glands and Ex-Proof-plugs, structural supports etc complete as per specifications and tender documents. | 4300 | 20 | EA |
431 | 4310 | Installation, integration, testing and commissioning of Ex-proof field mounted Driver Ack Push Button station along with FLP double compression glands and Ex-Proof-plug, structural supports etc complete as per specifications and tender documents. | 4310 | 20 | EA |
432 | 4320 | Installation, integration, testing and commissioning of Microprocessor based Field mounted dual arm Batch Controller with interface to minimum 2 nos. of main product + 2 nos. of blend product + 2 nos. of additive product in Flameproof and weather proof enclosure along with accessories like double compression glands, Exd Plugs, hoods, structural supports etc complete as per specification and tender document.\nOr\nInstallation, integration, testing and commissioning can supply 2 sets of Microprocessor based Field mounted single arm Batch Controller with interface to minimum 1 no. of main product + 1 no. of blend product + 1 no. of additive product in Flameproof and weather proof enclosure along with accessories like double compression glands, Exd Plugs, hoods, structural supports etc in place of Dual Arm Batch Controller complete as per specification and tender document. | 4320 | ||
433 | 4330 | For TLF product loading | 4330 | 12 | EA |
434 | 4340 | For TT calibration with water | 4340 | 1 | EA |
435 | 4350 | Installation, testing and commissioning of intrinsically safe / flameproof type proximity card reader along with mounting accessories etc complete as per specifications and tender document for authorisation of TT at | 4350 | ||
436 | 4360 | TLF bays (1 no. Per bay) | 4360 | 12 | EA |
437 | 4370 | License area Entry barrier gates ( 2 nos. X 2) | 4370 | 4 | EA |
438 | 4380 | License area Exit barrier gates ( 1 no. X 3) | 4380 | 3 | EA |
439 | 4390 | Security Exit barrier gates ( 1 no.) | 4390 | 1 | EA |
440 | 4400 | Security Entry barrier gates ( 1 no.) | 4400 | 1 | EA |
441 | 4410 | Near Security Gate/TT parking ( for TT registration ) | 4410 | 2 | EA |
442 | 4420 | Installation of pre-fabricated Metering Skid (MS structure) for mounting of complete metering equipments as per BOQ and schematic drawing for one main product, one blend product and one additive dosing system. The metering assembly comprises of : \n\nMain product line: Strainer cum Air eliminator, Spool piece with tapping for additive dosing, Online Master Meter proving manifold, MFM,Spool piece with tapping for Temprature Transmitter installation, Pressure transmitter, spool piece with tapping for connecting outlet of TRV, ON-Off valve, DCV, Spool Piece with tapping for Ethanol blending & TRV installation. \n\nBlend Product line: Strainer cum air eliminator, Online Master Meter proving manifold, MFM, Spool piece with tapping for Temperature Transmitter installation, ON-Off valve, DCV, NRV, isolation valve and finally connected to Main stream line tap off point after DCV. \n\nAdditive Dosing System comprises of isolation valve, Additive injection mono block, connecting piping, NRV, isolation valve and finally connecting to Main stream tap off point before MFM. \n\nProvision to be made in the skid for mounting of Batch Controller, Rack Monitor, Grounding unit, RIT, Driver's Ack Push button stations, card reader, FLP sockets, FLP junctions boxes (Power, Signal and Control), FLP power isolator switch, interconnecting cables from respective equipment to JBs, cable trays with covers, glands, support, MS structure,Electroforged galvanized grating, nuts, bolts, gaskets, Tees, bends, elbows, WNRF flanges, nozzles, plugs, isolators, any other equipment if required as per design Engineering etc complete as per specification and tender document. \n\nKindly note, irrespective of facility available or not, each metering skid shall have provision for installation of metering assembly of one main product, one blend product and one additive product as detailed in tender document. | 4420 | 20 | TO |
443 | 4430 | Note: \n1. All the equipments, JBs, cable trays, interconnecting cables etc as stated above to be installed and loop tested at factory. Complete assembly to be dispatched at site. The skid to be designed and fabricated by the party taking into consideration of all the equipment sizing, space available for mounting of the skid at the bottom of the gantry etc. The design Engineering along with weight calculation of individual skid excluding equipments to be submitted to IOCL prior to taking up fabrication job for review purpose. Payment shall be made based on theoretical weight calculation of the skid excluding weight of equipments, JBs, cable trays. The rate is also inclusive of surface preparation, powder coating, painting, transportation of the skid to site etc complete in all respect. \n2. All unuse nozzle/ tapping/ opening to be blind flanged.\n3. For SKO metering SKID, tapping to be provided in the skid for both bottom and top loading as per design Engineering.\n | 4430 | ||
444 | 4440 | Installation, integration, testing and commissioning of barrier gate of minimum boom length of 3 m along with accessories, controllers etc complete as per specification and tender document for installation at following location. | 4440 | ||
445 | 4450 | License area Entry gate | 4450 | 2 | SET |
446 | 4460 | License area Exit gate | 4460 | 3 | SET |
447 | 4470 | Security Exit gate | 4470 | 1 | SET |
448 | 4480 | Security Entry gate | 4480 | 1 | SET |
449 | 4490 | DISPLAY BOARDS | 4490 | ||
450 | 4500 | Installation, integration, testing and commissioning of weather proof LED bay queuing display board (Minimum 15 lines x 100 mm Character height x 25 characters per line) for outdoor installation at TT parking area / Customer service building along with accessories like public address system, speakers, amplifier, mike, structural steel for mounting of the same, Aluminium canopy/sunshade etc complete as per specifications and tender document. | 4500 | 1 | EA |
451 | 4510 | Installation, integration, testing and commissioning of LED monitor of minimum 55" along with required hardware and software for interfacing with TAS, lockable enclosure (wall / ceiling mounted) for mounting the monitor along with accessories at Driver's Rest Room for repeat display of 15 lines Bay Queue Display board complete as per specification and tender document. Kindly note, no additional payment shall be made for any additional hardware/ software/ cable etc required for integration of the monitor with TAS. | 4510 | 1 | EA |
452 | 4520 | Installation, integration, testing and commissioning of LED monitor of minimum 55" along with required hardware and software for interfacing with TAS, lockable enclosure (wall / ceiling mounted) for mounting the monitor along with accessories, Aluminium canopy/ sunshade etc at invoice room for displaying the list of TTs whose invoice has been generated and TT is still inside license area complete in all respect as per tender requirement. Kindly note, no additional payment shall be made for any additional hardware/ software/ cable etc required for integration of the monitor with TAS. | 4520 | 1 | EA |
453 | 4530 | Installation, integration, testing and commissioning of weather proof three line coloured LED display board with scroll and flash effects (Each line of min. 50 mm Character height x 11 characters per line) for outdoor application near Security Gate/ TT parking Area and license area Entry barrier Gate along with mounting structure, Aluminium canopy/ sunshade, accessories etc complete as per specifications and tender document for displaying the TT Registration no. in bilingual (English + local language) of reported TT whose proximity card has been shown on the PCR adjacent to the display board for TT reporting at security gate/TT parking area, TT status at TT parking area exit gate and the bay no. (Bilingual) etc of the authorised TT reported at license area Entry Gate as per FDR.\n2 nos. for TT reporting + 1 no. at Security Entry gate + 2 nos. per License Area Entry Barrier Gate (2X2) + 1 No. at Security Exit gate; Total - 2+1+4+1=8\nNote : 1 line for display in English & 2 lines for displaying in local language | 4530 | 8 | EA |
454 | 4540 | Ethanol Dosing System | 4540 | ||
455 | 4550 | Installation, integration, testing and commissioning of Microprocessor based Coriolis mass flow meter for white oil (Ethanol) application alongwith display unit and mounting accessories with adjustable screw support, reducer (if required) etc for line size 2" suitable for maximum flowrate of 500 LPM complete as per specifications and tender document for ethanol blending.\nNote: In case MFM is not having inbuilt ASTM table, vendor has to supply Flow Computers along with accessories as per tender document at no adddtional cost to IOCL . | 4550 | 8 | EA |
456 | 4560 | Installation, integration, testing and commissioning of Strainer cum Air eliminator for line size 50 mm with differential pressure transmitter across the Strainer along with accessories, SS tubing, needle valves etc complete as per specifications and tender document. | 4560 | 8 | EA |
457 | 4570 | Installation, integration, testing and commissioning of Multistage Piston type Digital Control Valve (DCV), NRV, isolation valve for line size 50 mm alongwith accessories, with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete as per specifications and tender document. | 4570 | 8 | EA |
458 | 4580 | Installation, integration, testing and commissioning of Piston type, hydraulically operated, solenoid operated ON-OFF Valve along with accessories, with secure locking arrangement of the needle valves to avoid manual throttling of the needle valves , tubing arrangement as per installation drawing etc for line size 50 mm complete as per specifications and tender document. | 4580 | 8 | EA |
459 | 4590 | Installation, integration, testing and commissioning of flameproof cum weather proof, Temperature transmitter along with display unit and keypad, RTD, Thermowell for line size 50mm, mounting accessories etc complete as per specifications and tender document. \nNote : One no. of additional thermo well along with accessories to be provided and installed on ethanol point for installation of Master Temperature transmitter with RTD. | 4590 | 8 | EA |
460 | 4600 | Installation, testing and commissioning of online proving valves manifold comprising of 1 no. manual operated DBBV without actuator and 2 nos. of 50 NB, full bore, zero leakage, fire safe ball valves along with associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, WNRF flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF MFM complete as per specifications and tender documents. | 4600 | 8 | SET |
461 | 4610 | Additive dosing System | 4610 | ||
462 | 4620 | Installation, integration, testing and commissioning of additive injection mono block along with accessories for XTRAPREMIUM and XTRAMILE complete as per specification and tender document.\nNote - All the wetted parts within Additive injection panel/ block shall be of SS 316 or better. | 4620 | 4 | SET |
463 | 4630 | Installation, testing and commissioning of Additive tanks (500 Litres each) and pump module for XTRAPREMIUM /XTRAMILE comprising of Additive Tank, Additive Pumps (Two per tank) , Mild Steel SKID, Flameproof Motor, NRV 25 mm, Flanged ball valve 25 mm, Pressure Relief Valve, Pressure Gauge with pulse dampener, Strainer 25 mm, interconnecting pipings (25 mm SS), flanges etc. auxiliary potential free contact/serial communication complete as per specification and tender document. | 4630 | ||
464 | 4640 | For Xtramile | 4640 | 1 | SET |
465 | 4650 | For XtraPremium | 4650 | 1 | SET |
466 | 4660 | laying ,welding & commissioning of ASTM A106 Gr B Schedule 80 pipe of 25 NB from additive header pipe to additive injection panel at TLF bay complete as per tender document.. | 4660 | 200 | M |
467 | 4670 | Laying ,welding and commissioning of Necessary hardware Like SS Tubing, reducer, Elbows, equal Tee ,unequal tee, Flanges, Coupling, Ball Valve for Isolation, NRV, 15 mm back pressure regulator on return line etc as required for piping and commissioning of the system complete in all respect. | 4670 | 1 | LS |
468 | 4680 | Note: Piping from Additive tank skid upto TLF header line along with isolation valve & return line shall be supplied and installed by IOCL. Integration of additive pumps for remote operation, level measurement shall be in the successful bidder's scope. | 4680 | ||
469 | 4690 | TLF Header line instruments | 4690 | ||
470 | 4700 | Installation,testing and commissioning of Bulk Air Eliminator as per product line size and flow requirement as per following sizes including mounting structure, foundation etc complete as per specification and tender document. | 4700 | ||
471 | 4710 | MS - 2.6 KL | 4710 | 1 | EA |
472 | 4720 | HSD - 2.6 KL | 4720 | 1 | EA |
473 | 4730 | ETHANOL-0.6 KL | 4730 | 1 | EA |
474 | 4740 | Installation,testing and commissioning of flameproof cum weather proof, min SIL 2 certified smart pressure transmitter with display unit & keypad, SS manifold, 1 no. isolation ball valve, Aluminium canopy/sunshade with mounting accessories etc on the TLF main header line complete as per specifications and tender document. \n(Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2) | 4740 | ||
475 | 4750 | TLF Header | 4750 | 3 | EA |
476 | 4760 | Tank Farm Management System | 4760 | ||
477 | 4770 | Installation, integration, testing and commissioning of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 4770 | ||
478 | 4780 | For Cone Roof Vertical Tanks (Primary and Secondary Radar Gauges) | 4780 | ||
479 | 4790 | HSD | 4790 | 6 | EA |
480 | 4800 | BIO-DIESEL | 4800 | 2 | EA |
481 | 4810 | PCK | 4810 | 4 | EA |
482 | 4820 | For Internal Floating Roof vertical tanks/Floating roof vertical tanks (Primary and Secondary Radar Gauges) | 4820 | ||
483 | 4830 | MS | 4830 | 6 | EA |
484 | 4840 | ETHANOL | 4840 | 4 | EA |
485 | 4850 | For U/G horizontal product tanks | 4850 | ||
486 | 4860 | MS | 4860 | 1 | EA |
487 | 4870 | HSD | 4870 | 1 | EA |
488 | 4880 | HSD (OWN) | 4880 | 1 | EA |
489 | 4890 | ETHANOL | 4890 | 1 | EA |
490 | 4900 | BIO-DIESEL | 4900 | 1 | EA |
491 | 4910 | Installation,integration,testing and commissioning of Non-contact type Radar level gauges with instrument accuracy of +/-3 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 4910 | ||
492 | 4920 | FIRE WATER | 4920 | 3 | EA |
493 | 4930 | SLUDGE | 4930 | 1 | EA |
494 | 4940 | Installation,integration,testing and commissioning of Guided wave RADAR type level gauge with transmitter , instrument accuracy of +/- 3 mm or better,in built digital display, along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) as per specification. | 4940 | ||
495 | 4950 | For Additive Tanks | 4950 | 2 | EA |
496 | 4960 | Installation,integration,testing and commissioning of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document. | 4960 | ||
497 | 4970 | With minimum 8 elements temperature sensor (for A/G vertical tanks) | 4970 | ||
498 | 4980 | For Cone Roof Vertical Tanks (Primary and Secondary Radar Gauges) | 4980 | ||
499 | 4990 | HSD | 4990 | 3 | EA |
500 | 5000 | BIO-DIESEL | 5000 | 1 | EA |
501 | 5010 | PCK | 5010 | 2 | EA |
502 | 5020 | For Internal Floating Roof vertical tanks/Floating roof vertical tanks (Primary and Secondary Radar Gauges) | 5020 | ||
503 | 5030 | MS | 5030 | 3 | EA |
504 | 5040 | ETHANOL | 5040 | 2 | EA |
505 | 5050 | For U/G horizontal product tanks | 5050 | ||
506 | 5060 | MS | 5060 | 1 | EA |
507 | 5070 | HSD | 5070 | 1 | EA |
508 | 5080 | HSD (OWN) | 5080 | 1 | EA |
509 | 5090 | ETHANOL | 5090 | 1 | EA |
510 | 5100 | BIO-DIESEL | 5100 | 1 | EA |
511 | 5110 | Installation,integration,testing and commissioning of Density probe along with accessories etc for density measurement of the product in product tanks complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 5110 | ||
512 | 5120 | For A/G vertical tanks - Three elements | 5120 | ||
513 | 5130 | For Cone Roof Vertical Tanks (Primary and Secondary Radar Gauges) | 5130 | ||
514 | 5140 | HSD | 5140 | 3 | EA |
515 | 5150 | BIO-DIESEL | 5150 | 1 | EA |
516 | 5160 | PCK | 5160 | 2 | EA |
517 | 5170 | For Internal Floating Roof vertical tanks/Floating roof vertical tanks (Primary and Secondary Radar Gauges) | 5170 | ||
518 | 5180 | MS | 5180 | 3 | EA |
519 | 5190 | ETHANOL | 5190 | 2 | EA |
520 | 5200 | For U/G horizontal product tanks-One element | 5200 | ||
521 | 5210 | MS | 5210 | 1 | EA |
522 | 5220 | HSD | 5220 | 1 | EA |
523 | 5230 | HSD (OWN) | 5230 | 1 | EA |
524 | 5240 | ETHANOL | 5240 | 1 | EA |
525 | 5250 | BIO-DIESEL | 5250 | 1 | EA |
526 | 5260 | Installation,integration,testing and commissioning of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tank inventory data. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 5260 | ||
527 | 5270 | For A/G Vertical Product tanks - (Primary & Secondary Radar Gauges) | 5270 | 22 | EA |
528 | 5280 | For U/G Product tanks | 5280 | 5 | EA |
529 | 5290 | For water tanks | 5290 | 3 | EA |
530 | 5300 | For Sludge tank | 5300 | 1 | EA |
531 | 5310 | Installation,integration,testing and commissioning of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc complete as per specification and tender document | 5310 | ||
532 | 5320 | For A/G Vertical Product tanks | 5320 | 11 | EA |
533 | 5330 | For U/G horizontal product tanks | 5330 | 5 | EA |
534 | 5340 | Installation, testing, integration and commissioning of Auto Tank Gauging (ATG) probe combo with density measurement (Wireless or Wired) including necessary accessories as per Tender specifications. | 5340 | 1 | EA |
535 | 5350 | Installation,integration,testing and commissioning of parallel redundant Communication Interface Units (CIU) including all accessories etc for tank farm management system complete as per specification and tender document. | 5350 | ||
536 | 5360 | For Primary Radar gauges installed on A/G vertical , under ground product tank, water tank ,slope ,additive & Sludge tank etc. | 5360 | 1 | SET |
537 | 5370 | For Secondary Radar Gauges installed on A/G product tanks | 5370 | 1 | SET |
538 | 5380 | Installation,integration, testing and commissioning of 1 no. of Redundant TFMS Server (Form Factor:Rack ,Mountable in 19" rack ) along with 1 no. rack type (1U) ,one no. Min. 19" LED monitor with keyboard & mouse ,suitable for 19" mounting & 24x7 operation, Licensed OS (latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed software from Radar Gauge OEM etc complete as per specification and tender document. | 5380 | 1 | SET |
539 | 5390 | Installation,integration,testing and commissioning of TFMS Workstation with minimum 27" LED colour monitor, keyboard, mouse, KVM Switch, Licensed OS(latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed client software from same Radar Gauge OEM etc complete as per specification and tender document. \nNote:CPU of control room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost | 5390 | ||
540 | 5400 | 19" Rack type at Control Room, form factor - Rack, CPU height - 2U (Maximum) | 5400 | 1 | EA |
541 | 5410 | Push Buttons Outside Dyke Walls | 5410 | ||
542 | 5420 | Installation,integration,testing and commissioning of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for remote opening and closing of ROSOVs from LPBS, along with FLP double compression gland, Tag plates,TBs, mounting structure, accessories etc complete as per specifications and tender document. | 5420 | ||
543 | 5430 | For ROSOVs (A/G product tank's inlet, outlet and recirculation line) | 5430 | 28 | EA |
544 | 5440 | ESD PUSH BUTTON STATION | 5440 | ||
545 | 5450 | Installation,testing and commissioning of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document. | 5450 | ||
546 | 5460 | Local ESD Push Button Station ( Each Battery of TLF -1X2 no., TLF pump house - 1 no.) | 5460 | 3 | EA |
547 | 5470 | Plant ESD Push Button Station ( Each battery of TLF - 1X2 No.) | 5470 | 2 | EA |
548 | 5480 | Installation,integration,testing and commissioning of ESD push button stations (for indoor application), mushroom head type with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document. (control room - 1 no., security room - 1 no., TM's cabin - 1 no.) | 5480 | 3 | EA |
549 | 5490 | Control Room equipments | 5490 | ||
550 | 5500 | Design, engineering, installation, configuration, integration, testing and commissioning of redundant fault tolerant Integrated Distributed Control System (DCS) along with DCS Panels, Marshalling Panels, keypad cum contactless smart card reader with accessories, limit switches, Input Output modules, Power supply units, Relays with base, barriers, TBs, Redundant host communication ports, Serial Interface Modules, HART modules, other communication modules, HMI , wirings, glands, plugs, other modules/ hardware required for interfacing with all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document.\nNote: Any other hardware, software, OPC server, Historian Server, storage, firewall, functional control key board etc required as per tender specification and design requirements, the same to be provided by the vendor at no additional cost to IOCL. | 5500 | 1 | SET |
551 | 5510 | Design, installation, configuration, integration, testing and commissioning of Complete Terminal Automation Software along with required licences, dongle/keys, GUI, SCADA etc meeting the complete functional and technical requirements of the tender document. \nVendor to provide required software, licences, dongle/keys, GUI, SCADA etc for TAS Management Server, Distributed Control System, Operator work stations, fire fighting OIC, Alarm display and annunciation OIC, Engineering Work Stations(for safety PLC & DCS), Web Server, OPC Server, Historian Server / work station, any other devices connected to Control & Management LAN of the integrated Distributed Control System complete as per specification and tender document.\nTAS software shall be interfaced with following but not limited to major sub-systems / equipments alongwith GUI development for monitoring, logging, reporting, controls & interlocks etc as per specification and tender document.\n- Safety PLC\n- TAS-Management Server\n- TLF Automation System (TT reporting, registration & entry system, TT Queuing, FAN generation, TT registration number reading system, Photo pass management system,TT crew authorization system,Bay allocation, Additive Dosing system, Ethanol blending System, Interface with TLF equipments like BCU, MFM, Barrier Gates, Bay Queue Display, Bay allocation Display, Invoice generated display, rack monitors, Proximity card readers etc)\n-Tank Wagon loading Automation system (Rake inventory System,Rake registration system, FAN generation, Tank wagon allocation, Interface with TWG equipments like BCU, MFM etc,SAP-TWG integation)\n-Tank Wagon unloading Automation system\n-Tank Lorry Decantation System\n-TT calibration System\n-Bio Diesel Blending system \n- ANPR and Face recognisation | 5510 | 1 | LS |
552 | 5520 | -- Valve Automation System (ROSOVs, MOVs, DBBV, MCS Interface, SOVs, etc)\n-Tank Farm Management System ( TFMS Server, Primary & Secondary Radar Gauging, AOPS, Level transmitters, Level Switch, Density probes, MSTW, CIU etc)\n- Pipeline/ Refinery PLC Interface, OMC PLC interface\n - MCC, Pump, Borewell, DG Sets, Air compressors, VFDs\n- PA paging Interface \n- HC Detection System Interface\n-FAS Interface, Fire Fighting System, HVLR, Fire Alarm System Interface, Fire Engines, DG Set, Jockey pumps, Foam pumps, CFFS, Sprinkler & Fixed foam pourer system etc\n- VRU Package Units\n- Effluent Treatment plant\n- CCTV systems\n- Access Control System\n- SKO Blue Dye Dosing System\n- ESD System, Emergency panel, Power ESD, Local ESD, Wailing sirens\n- Pressure Transmitters\n- UPS & Power distribution boards etc\n- Interface with IOCL SAP through firewall\n- Visitor Management Software for setup, configuration, operation, events, history and archiving, recording, printing etc. complete as per specification and tender document - Any other Third Party Interface/ devices as per scope of the work order etc\nNote: The offered software shall also includes fault detection module and Web Server software for remote over IOCL Intranet across India as detatiled in the tender document.\n\n\n\n | 5520 | ||
553 | 5530 | Design, engineering, installation, configuration, integration, testing and commissioning of Redundant SIL 3 TUV/ EXIDA certified Safety PLC along with PLC Panels, Marshalling Panels, Keypad cum contactless smart card reader with accessories, limit switches, Dual redundant Input Output modules, Power supply units, Relays with base, barriers, TBs, Dual Ethernet ports per processor, Serial Interface Modules, HMI , wirings, glands, plugs, other modules/ hardware required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document.\nNote: The offered safety PLC shall be of the same make family of the integrated Distributed Control System. | 5530 | 1 | SET |
554 | 5540 | Design, engineering, installation, configuration, integration, testing and commissioning of redundant TAS Management Server (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LCD/LED monitor of minimum size of 19" suitable for 24x7 operation along with High availability redundancy software working on redundant (Primary and Secondary) hot standby mode , keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document.\n OR\nDesign, engineering, installation, configuration, integration, testing and commissioning of Dual Mode Redundant Grade with built in redundancy TAS Management Server (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LED monitor of minimum size of 19" suitable for 24x7 operation, keyboard drawer, optical mouse and combo 4 port KVM switch (if required) , OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document. \n\nTAS Management Servers (TAS-MS) shall have either of the above mentioned configuration meeting the complete specification and tender requirements. \n\nIn addition, the TAS-MS shall be configured to have Zero Downtime to repair, Full data redundancy shall be provided using proven technology , it shall also provide port level redundancy.The system solution shall be capable of self fault detection and isolation, all necessary hardware/software configuration etc to achieve the same shall be included. | 5540 | 1 | LOT |
555 | 5550 | Installation & commissioning of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like keypad cum contactless smart card reader for front & back door seperately with accessories, limit switches, earthing arrangements, breaker, fuses, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments. | 5550 | ||
556 | 5560 | For mounting of TAS Management Servers along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, Ethernet switch, GSM modems, MCBs etc as per specification and tender document. | 5560 | 1 | EA |
557 | 5570 | For mounting of CCTV Servers, Analytics Servers, NAS/SAN along with associated rack mounted monitors & keyboard, mouse, 4 port industrial grade KVM switches, power adapters, layer 3 Ethernet switch, MCBs etc as per specification and tender document. | 5570 | 2 | EA |
558 | 5580 | For mounting of Redundant ACS cum photopass management Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking components, MCBs etc as per specification and tender document. | 5580 | 1 | EA |
559 | 5590 | For mounting of Redundant TFMS Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, CIUs, MCBs etc as per specification and tender document. | 5590 | 1 | EA |
560 | 5600 | For mounting of Rack mounted Master Control Stations for MOVs & DBBVs along with power adaptors, MCBs, required accessories etc as per specification and tender document. | 5600 | 2 | EA |
561 | 5610 | For mounting of Rack mounted CPUs of Control room console workstation (Rack type) , one number 19" rack mounted monitor, rack mounted keyboard, mouse, KVM switches for connection of all CPUs along with power adaptors, MCBs, required accessories etc as per specification and tender document. | 5610 | 2 | EA |
562 | 5620 | For mounting of Network equipments along with power adaptors, MCBs, required accessories etc as per specification and tender document. | 5620 | 1 | EA |
563 | 5630 | Installation, configuration, integration, testing and commissioning of Operator Interface Console Computer (OIC) with minimum 27" colour LED monitor,keyboard, mouse,KVM Switch, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. \nNote: CPU shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost. | 5630 | ||
564 | 5640 | 19" Rack mounted at Control Room, form factor - Rack , Max. 2U height ( 3 OICs, 1 for alarm Display, 1 for fire fighting System) | 5640 | 5 | EA |
565 | 5650 | Installation, configuration, integration, testing and commissioning of Operator Interface Console Computer (OIC) minimum 27" colour LED monitor, keyboard, mouse, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. | 5650 | ||
566 | 5660 | Tower type in TM's Cabin + Pipeline Division control room | 5660 | 2 | EA |
567 | 5670 | Installation, configuration, integration, testing and commissioning of Engineering Workstation (EWS) with minimum 27" colour LED monitor, keyboard, mouse, KVM Switch, Safety PLC & DCS software, HMI software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. (Locations: 1 no. in CR for both DCS and Safety PLC) \nNote: In case of Tower type workstation is supplied in place of Rack type.Rack mount Kit to be provided for installation in the 19" Rack.\nNote: CPU shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost. | 5670 | ||
568 | 5680 | 19" Rack mounted at Control Room, Form factor - Rack , Max. 2U height | 5680 | 1 | EA |
569 | 5690 | Installation, configuration, integration, testing and commissioning of Tank Truck Entry System (TTES) Workstation with minimum 27" colour LED monitor, keyboard, mouse,KVM switch, software, SCADA, GUI, OS, Antivirus etc. complete as per specifications and tender document. \nNote: CPU of contol room shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost. | 5690 | ||
570 | 5700 | 19" Rack mounted at Control Room, Form factor - Rack , Max. 2U height | 5700 | 1 | EA |
571 | 5710 | Tower type in Customer service block (2 nos.) and Lock shed room (1 no.) | 5710 | 3 | EA |
572 | 5720 | Installation, configuration, integration, testing and commissioning of minimum 19" colored LED monitor (19" Rack type at panel Room, form factor - Rack, height - 1U) with , KVM switch, Rack type keyboard, mouse etc located in Control Room complete as per specifications and Tender Document. (For CPUs of Console kept in panel room) | 5720 | 2 | EA |
573 | 5730 | Installation, configuration, integration, testing and commissioning of Web Server (Rack type mountable in 19" rack ) ,Rack type CPU -2U Max. , LED monitor of minimum size of 27" suitable for 24x7 operation, keyboard, mouse, KVM Switch, web application software, SCADA, GUI, OS, Antivirus etc located in panel Room complete as per specifications and Tender Document. \nNote: CPU shall be kept in Panel room in 42 U Rack. KVM extender & reciever is to be supplied at no additional cost. | 5730 | 1 | EA |
574 | 5740 | Installation, integration, maintenance and operation of the NMS System covering Network Devices operational in Terminal Automation System. The Offered Network Management Solution (NMS) solution should support at least the following:\n• All the proposed NMS Components should be from single vendor. \n• NMS Software should support Graphical view up to port level for the all the devices.\nDiscovery of Network Elements.\n• Real time Traffic monitoring of Network Links and Devices with Historical reports for various periods.\n• Management of SNMPv1, SNMPv2, SNMPv3 & MIB etc.\n• Configuration of thresholds for Generating alarms.\n• Configuration of alarm actions (visual, audible, email, sms etc.) for each \nNetwork element.\n• Should be able to provide secured windows based consoles / secured web based consoles for accessibility to NMS.\n• Should have web browser interface with user name and Password Authentication.\n• Administrator/ Manager should have privilege to create/modify/delete user.\n• NMS should have support for SNMPv3 & IPv6, including dual-stack IPv4 & IPv6 to provide flexibility in protocol strategy and implementation.\n | 5740 | 1 | LS |
575 | 5750 | Installation, configuration, integration, testing and commissioning of Terminal servers (rack mounted) with inbuilt/externally mounted lightening and Surge Protection Device Type (1+2) at all Serial ports, for interfacing and integration of card readers, Bay Queue display units (Indoor & outdoor), LED Display unit for TT reporting,at Main Entry gate & Exit gate and TLF Entry gate for Bay allocation with TAS.In case the above listed equipments do not come with open communication protocol compatible to be directly interfaced with DCS Serial / MODBUS TCP IP module complete as per specification and tender document.\n\nNote: Terminal Servers to be configured in Dual Redundant mode. | 5750 | ||
576 | 5760 | 16 ports at Control Room | 5760 | 2 | EA |
577 | 5770 | Installation, configuration, integration, testing and commissioning of 24 ports Layer 3 Managed Ethernet Switches (10/100/1000 MBPS) with SFP, copper, fibre modules/ports along with accessories for connecting Plant management LAN equipments like CCTV System, TAS - MS Server/ Redundant OPC server, TFMS Server, TFMS work station, OICs, IOCL intranet for SAP connectivity through fire wall, Network printers, Access Control Server, Web Server Access over IOCL Intranet, connecting to OIC/ work stations etc which needs to be connected to both Plant Management LAN and Plant Control LAN for getting the entire GUIs of Complete Terminal Automation System and any other third party devices for interfacing with DCS etc.\nNote: \n1. Ethernet Switches to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs and any other equipment which are to be connected to above switch and the communication is through OFC cable. | 5770 | 2 | EA |
578 | 5780 | Installation, configuration, integration, testing and commissioning of minimum 24 ports Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fibre modules, accessories for connecting equipments installed in Plant Control LAN like TAS- MS Servers, OICs, TTES cum TWES , EWS, OPC Servers, Fire fighting OICs, Alarm Display OIC, DCS, Safety PLC, inter connecting building work stations etc as per system architecture and design requirement complete as per specification and tender document.\nNote:\n1. The switches are to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs, and any other equipment which are to be connected to above switch and the communication is through OFC cable. | 5780 | 2 | EA |
579 | 5790 | Installation, configuration, integration, testing and commissioning of Layer 2 Managed Ethernet Switches along with accessories for connecting BCU with TAS, equipments installed in Customer service room, Lock room, Security room, Terminal Manager room and other TAS equipments as per system architecture and design requirement complete as per specification and tender document.\nNote: \n1. Ethernet switches for BCU communication shall have suitable mounting arrangement to mount inside FLP JBs. \n2. The switches are to be configured in Dual Redundant mode.\n3. All OICs, Workstations, Servers other than that of CCTV, ACS & TFMS are to be connected to both plant management and control LAN so that all the GUIs can be seen in all the PCs irrespective of its nomenclature like TTES, OIC, EWS, TM PC etc.\n4. Printers to be connected to Plant Management LAN and to be configured to all PCs, Workstation, TTES etc so that printout command can be issued from any of the Machine. | 5790 | ||
580 | 5800 | For BCU integration at TLF (copper ports of 10/100/1000 MBPS)-( Minimum 8 nos. copper ports and 2 nos. optical ports) | 5800 | 8 | EA |
581 | 5810 | For BCU integration at TT Calibration shed-2 Nos (copper ports of 10/100/1000 MBPS)-(Minimum 4 nos. copper ports and 2 nos. optical ports) | 5810 | 2 | EA |
582 | 5820 | For connecting all MODBUS TCP IP devices ( any other devices) to DCS Ethernet port directly for integration (copper ports of 10/100/1000 MBPS)- to be located in Control Room ( Minimum 8 nos. copper ports and 2 nos. optical ports) | 5820 | 2 | EA |
583 | 5830 | At Lock Shed - copper ports of 10/100/1000 MBPS [control LAN - 2 nos. & Management LAN - 2 nos.] ( Minimum 8 nos. copper ports and 2 nos. optical ports) | 5830 | 4 | EA |
584 | 5840 | At Admin Building for TM cabin - copper ports of 10/100/1000 MBPS [control LAN - 2 nos., Management LAN - 2 nos., CCTV - 2 no.] (Minimum 8 nos. copper ports and 2 nos. optical ports) | 5840 | 6 | EA |
585 | 5850 | At Security Room - copper ports of 10/100/1000 MBPS [Management LAN - 2 nos.,CCTV - 2 no.] (Minimum 8 nos. copper ports and 2 nos. optical ports) | 5850 | 4 | EA |
586 | 5860 | At Driver rest room - copper ports of 10/100/1000 MBPS [Managent LAN - 2 nos.] (Minimum 4 nos. copper ports and 2 nos. optical ports) | 5860 | 2 | EA |
587 | 5870 | Installation, testing and commissioning of industrial grade redundant Serial to Ethernet converter of 8 port with mounting acessories etc complete in all respect as per specification and tender document. (Ports:- 6 Main + 2 Spare) | 5870 | ||
588 | 5880 | For MFM and other serial devices integration to DCS -TLF | 5880 | 4 | EA |
589 | 5890 | Installation, testing and commissioning of Wall mounted/wheel mounted Network Rack-minimum 19U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at Security Room, TM room, Invoice Room for TAS equipments | 5890 | 4 | EA |
590 | 5900 | Installation, configuration, integration, testing and commissioning of Monochrome Laser Printer along with accessories for TAS and TFMS report printing in control room (2 nos.) and 2 nos. at security room complete as per specifications and tender document. | 5900 | 4 | EA |
591 | 5910 | Installation, configuration, integration, testing and commissioning of heavy duty high speed laser printer and accessories for invoice printing in lock shed room, complete as per specifications and tender document. | 5910 | 2 | EA |
592 | 5920 | Installation, integration, testing and commissioning of parallel redundant UPS of minimum capacity of 60 KVA or as per load calculation (whichever is higher) for entire TAS equipments and third party devices integrated with TAS and powered through TAS UPS with 30% spare capacity for future load connection. The scope also includes supply of parallel battery bank (2x50%) for minimum back up time of ½ hour at full load (rated capacity) along with stand, supports for mounting of the UPS and batteries etc complete as per specification and tender document. The batteries shall be Sealed Maintenance free type. | 5920 | 1 | SET |
593 | 5930 | Installation, integration, testing and commissioning of UPS Power Distribution Panel along with Keypad cum contactless smart card reader for front and rear gate sepearately with accessories for powering DCS Panel, Safety PLC Panel, TAS-MS, OIC, EWS, TFMS System, TTES, printers, Bay Instruments other control room equipments, Tank Farm Instruments, CCTV system, Fire Detection System, Access control system, Bay Queue Display boards, other display boards, ROSOV ESD port, header line instruments and any other TAS equipments where UPS power are required for smooth un-interrupted operation. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation, MCB etc are to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring with digital voltmeter & digital ammeter separately for UPS and Auxilliary supply for front and rear seperately etc as per specifications and tender document.\nNote: Minimum 20% spare power points to be made available for future use. | 5930 | 1 | LS |
594 | 5940 | Installation & fixing of Open desk operator consoles, chairs, printer tables etc complete as per specification and tender document. | 5940 | ||
595 | 5950 | Open desk operator consoles for mounting of monitor in two tiers , 2 nos. of key boards, 2 nos. of mouse, accesscories e.g. Telephone,VHF sets, Master control station for PA paging, storage etc complete as per specification and tender document.\n(For mounting of 3 nos. OICs monitor, 1 no. Alarm Display OIC monitor, 1 no. Fire fighting OIC monitor, 1 no. TTES monitor , 1 TFMS workstation monitor, 1 no. CCTV client monitor,1 no. EWS monitor,1 Web server, storage etc.) | 5950 | 7 | EA |
596 | 5960 | Standard Printer Tables of Godrej or equivalent make (2 nos. at security gate, 1 no. in Lock shed room, 1 no. in security room for visitor management) | 5960 | 7 | EA |
597 | 5970 | Standard Computer Table of Godrej or equivalent make for installation of CCTV client , ACS client in security room (2 nos.),Photo pass management PC(1 No.), TTES in Customer service room (2 nos.) and TTES in lock shed room (1 no.) | 5970 | 6 | EA |
598 | 5980 | Installation, integration, configuration, testing and commissioning of IP based Redundant GSM modem suitable for 24x7 operation along with accessories for auto SMS as per specification and tender document. | 5980 | 1 | EA |
599 | 5990 | Hydrocarbon Detection system | 5990 | ||
600 | 6000 | Conducting fire and hydrocarbon vapour mapping study through reputed agencies having proven track record of conducting similar studies for oil installation across globe,using standard licensed software along with submission of study reports as per specification and tender document. | 6000 | 1 | EA |
601 | 6010 | Installation, integration, calibration, testing and commissioning of Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon vapour detectors along with calibration kit, accessories and structural supports, Aluminium canopy/sunshade etc as per specification and tender document. | 6010 | ||
602 | 6020 | Point type Infrared detector\n(Indicative location: Each tank dyke sump pit inside dyke wall -7 nos., Near ROSOVs of MS tanks:-3 Nos., Ethanol tanks- 2 nos.,Tx Tanks - 2 nos., TLF pump seal (MS+Ethanol) - 6 Nos,Sludge pump seal-3 No.,Tx Pump-1 No., Pump house drain pit - 1 no.; Vapour recovery system drain pit - 1 no.,ETP-1 No.,PL sump tank -1 No., PL Near SLB/SRB - 1 No.,PL Delivery Manifold - 1 No., PL Booster Manifold - 1 No.,PL main line Pump seal - 3 No.) | 6020 | 34 | EA |
603 | 6030 | Open path type Infrared detector (10-60 m) along with alignment telescope, configuration & Testing kit etc (Tentative location: MS tanks - 8 Nos. , Tx Tanks - 3 nos. & Ethanol tanks covering ROSOVs - 3 nos., Main Line & Booster Pump Shed - 2 Nos.) | 6030 | 16 | EA |
604 | 6040 | Open path type Infrared detector (10-90 m) along with alignment telescope, configuration & testing kit etc (Tentative location: TLF PH-3 Nos) | 6040 | 3 | EA |
605 | 6050 | Installation, integration, calibration, testing and commissioning of Flameproof cum weather proof (IP 66 or better) min SIL 2 certified UV/IR Flame detectors along with mounting arrangments, accessories and structural supports, Aluminium canopy/sunshade etc as per specification and tender document. | 6050 | ||
606 | 6060 | Main Line Pump Shed - 6 Nos., Booster Pump Shed - 2 Nos. | 6060 | 8 | EA |
607 | 6070 | Installation, integration, testing and commissioning of weather proof and Explosion proof Hooter cum beacons/ flash light along with accessories and structural supports as per specification.( Tentative location : Each product tank dyke (MS)-1 No.,(Ethanol & Tx)-1 No., Pump House (TLF) - 1 No.,ETP-1 No.,VRU-1 No., PL Station - 1 No.) | 6070 | 6 | EA |
608 | 6080 | Automatic Fire Detection and Alarm System | 6080 | ||
609 | 6090 | Installation, integration, testing and commissioning of microprocessor based automatic Fire Alarm Panel along with required Software, and hardware like Control module, monitor module, fault isolation module (in built/ External), mounting structure support etc complete as per standard design engineering, specification and tender document.\nLocation : Control Room | 6090 | 1 | EA |
610 | 6100 | Installation, integration, testing and commissioning of Repeater Panel along with software, hardware, mounting accessories etc required as per standard design Engineer, specifications and tender document complete in all respect. \n | 6100 | ||
611 | 6110 | Security Gate - 1 no., Fire Pump House - 1 no., Pipeline control room - 1 no. | 6110 | 3 | EA |
612 | 6120 | Installation, integration, testing and commissioning of addressable type detectors along with accessories, fault isolation module (Inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 6120 | ||
613 | 6130 | Combination/Multi-sensor Detector | 6130 | 585 | EA |
614 | 6140 | Rate of Rise Heat Detector | 6140 | 11 | EA |
615 | 6150 | IS detector | 6150 | 22 | EA |
616 | 6160 | Hydrogen Detector | 6160 | 4 | EA |
617 | 6170 | Installation, integration, testing and commissioning of Manual Call Point along with accessories, fault isolation module (Inbuilt/ External) and structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 6170 | ||
618 | 6180 | Ex-proof and weather proof MCP | 6180 | 18 | EA |
619 | 6190 | Weather proof MCP | 6190 | 23 | EA |
620 | 6200 | Installation, integration, testing and commissioning of Hooter along with accessories, fault isolation module (inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 6200 | ||
621 | 6210 | Weather proof Hooter cum Beacon | 6210 | 21 | EA |
622 | 6220 | Installation, integration, testing and commissioning of Response Indicator along with accessories, mounting structure etc required as per standard design engineering, specification and tender document complete in all respect. | 6220 | 218 | EA |
623 | 6230 | Access Control System | 6230 | ||
624 | 6240 | Installation, integration, testing and commissioning of half man height bi-directional turnstile (tripod) with controller along with accessories, mounting structure, pressure sensor etc required as per standard design engineering, specification and tender document complete in all respect. | 6240 | ||
625 | 6250 | License area entry & exit gate (Marketing)- 2 nos. ,License area entry & exit gate (LPG)- 2 nos. , Entry/Exit to tank farm area - 4 nos. | 6250 | 8 | EA |
626 | 6260 | Installation, integration, testing and commissioning of half man height dual lane Uni-directional turnstile (tripod) with controller along with accessories, mounting structure, pressure sensor etc required as per standard design engineering, specification and tender document complete in all respect. | 6260 | ||
627 | 6270 | At security entry gate/exit gate | 6270 | 3 | SET |
628 | 6280 | Installation, integration, testing and commissioning of Retractable Dual Lane Flap barrier with controller along with accessories, mounting structure, pressure sensor etc required as per standard design, engineering, specification and tender document complete in all respect. | 6280 | ||
629 | 6290 | Admin building entry/exit | 6290 | 2 | SET |
630 | 6300 | Installation, integration, testing and commissioning of face detection cum fingerprint cum contactless type smart card reader with controller along with electromagnetic door lock of 600 lb for single door/double door, 2 nos. of door position magnetic contact with buzzer etc as per specifications and tender document. \nNote: EM locks to be provided at no additional cost to IOCL. | 6300 | ||
631 | 6310 | Console room entry/exit door (Mkt+ LPG+Pipeline) - 10 nos., Panel room entry/exit door (Mkt+ LPG+Pipeline)- 10 nos. ,Console Room Exit Gate (Emergency)-1x2 no | 6310 | 22 | EA |
632 | 6320 | Installation, integration, testing and commissioning of Biometric fingerprint cum contactless type smart card reader along with accessories, software , programming kit etc required as per standard design engineering, specification and tender document complete in all respect. | 6320 | ||
633 | 6330 | Location:-(Turnstile:- Security entry/exit gate (Bi-directional)- Mkt - : 6x2 nos,License area (TLF) entry/exit gates (Bi-directional) - Mkt - : 2x2 nos,Entry/exit to tank farm area (Bi-directional)- Mkt- : 4x2 nos,Panel room Exit Gate (Mkt + Pipeline+LPG)-1x2 no,TLF/Tank Farm Area Entry/Exit (Bi-directional) -LPG - 2x2 nos,Flap barrier - 4x2nos.-Admin Building.) | 6330 | 38 | EA |
634 | 6340 | Installation, integration, testing and commissioning of Door Frame Metal Detector, 4 nos. hand held metal detector along with accessories, mounting structure etc complete as per specification and tender document. | 6340 | 1 | SET |
635 | 6350 | Installation of 2"size SS 304 guiding rail along with mounting accessories complete as per specification and tender document near turnstile/ tripod/flap barrier etc to prevent un-authorised movement. | 6350 | 100 | M |
636 | 6360 | Installation, configuration, integration, testing and commissioning of Redudnant ACS Server for photo pass management & visitor management (19" Rack type at panel Room, form factor - Rack, CPU height - 2U) with minimum 19" colored LED monitor, KVM switch, keyboard, mouse, OS, Antivirus etc located in Control Room complete as per specifications and Tender Document. | 6360 | 1 | EA |
637 | 6370 | Installation, configuration, integration, testing and commissioning of Access Control cum photopass management System Software for setup, configuration, operation, events, history and archiving, alarm monitoring, recording, printing, time and attendance etc. complete as per specification and tender document including hardwired interface with TAS for ESD input. | 6370 | 1 | SET |
638 | 6380 | Installation, configuration,integration, testing and commissioning of Client workstation of ACS cum Photopass management with minimum 27" coloured monitor,keyboard, mouse,KVM switch for Rack CPU, OS, Antivirus, HD coloured video camera (for taking visitors photograph) etc for ID badging & issuing of Visitor pass/Photo pass at security Room & other etc. complete as per specifications. | 6380 | ||
639 | 6390 | Rack Type - CPU in panel room with KVM sitch; Keyboard, mouse along with monitor etc. to be installed in security room for visitor pass | 6390 | 1 | EA |
640 | 6400 | Tower Type in Photopass room for TT crew/Contractor etc. | 6400 | 1 | EA |
641 | 6410 | Installation, configuration, integration, testing and commissioning of Laser printer (Monochrome) for Visitor pass printing having flexibility to print on A4, A5, A6 paper complete as per specification and tender document. | 6410 | 1 | EA |
642 | 6420 | Installation, configuration, integration, testing and commissioning of Colour photo pass printer along with integrated/seperate scanner for photo pass printing as per specification and tender document. | 6420 | 2 | EA |
643 | 6430 | IP BASED CCTV SURVEILLANCE SYSTEM | 6430 | ||
644 | 6440 | Installation, configuration, integration, testing and commissioning of HD IP Fixed Dome camera with IR and MFZ lens (2MP) along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 6440 | 10 | EA |
645 | 6450 | Installation, configuration, integration, testing and commissioning of HD IP PTZ Camera (2MP) along with power supply unit (POE based) with POE injector (industrial grade),with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 6450 | 31 | EA |
646 | 6460 | Installation, configuration, integration, testing and commissioning of IP Fixed Bullet cameras with MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 6460 | 9 | EA |
647 | 6470 | Installation, configuration, integration, testing and commissioning of IP Fixed Box cameras with varifocal lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 6470 | 58 | EA |
648 | 6480 | Installation, configuration, integration, testing and commissioning of Integral Explosion Proof HD IP Fixed Cameras and MFZ lens (2MP) along with power supply unit , with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document. | 6480 | 10 | EA |
649 | 6490 | Installation, configuration, integration, testing and commissioning of HD varifocal IP Fixed Outdoor Box Camera (2MP) along with power supply unit (POE based) , with inbuilt/external surge protection unit and mounting accessories per the tender specifications and instructions of Engineer in charge | 6490 | 1 | EA |
650 | 6500 | Installation, configuration, integration, testing and commissioning of 4 port Industrial grade layer 2 Managed POE based Ethernet Switch for connecting Cameras with 4 Nos. RJ copper port and 2 Nos. optical fibre ports with inbuilt/external surge protector (Type 1+2) at the input power supply as per specifications and Tender Document. | 6500 | 60 | EA |
651 | 6510 | Installation, configuration, integration, testing and commissioning of outdoor Explosion proof cum weatherproof housing (IP 65 or better) suitable for installing Layer 2 switch, PSU, LIU and adaptor for Ethernet switch/media convertor, surge protectors and other accessories of CCTV cameras. Supply of required OFC components & accessories like LIU, splice trays, loaded adaptor, blank plates, UTP cables, Fibre patch cords, pigtails, tags, ties, Ethernet cable with RJ45 connector etc complete in all respect for functioning of CCTV camera.The scope also includes supply of Exd. blinding plugs, Exd. double compression cable glands etc as per specifications and Tender Document. | 6510 | 60 | EA |
652 | 6520 | Installation,errection & foundation of Heavy Duty self supported Hot Dip Galvanized Poles for mounting of CCTV cameras along with civil foundation along with GI foundation bolt, mounting brackets, ladder arrangement (taking into account of safety during climbing) on the pole for installation and maintenance of cameras, SS nut & bolts for fixing camera and other accessories required for complete installation and commissioning of the pole, submission of structural stability certificate based on existing soil bearing capacity and wind speed from Govt. Engineering colleges etc complete as per specifications and Tender Document of below mentioned height of the pole. (Foundation drawing and other details to be submitted prior to installation as per tender document)\nNote: In case pole do not have ladder arrangment for maintenance purpose, then vendor to arrange for ladder for installation & maintenance purpose throughout the contract period including CAMC period at no additional cost to IOCL. | 6520 | ||
653 | 6530 | 10 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m, 2 PTZ camera at 10 m and LED flood light at 8m of the pole across perimeter as per tender | 6530 | 8 | EA |
654 | 6540 | 12 M pole with/without cantilever arrangement | 6540 | 13 | EA |
655 | 6550 | 15 M pole with/without cantilever arrangement | 6550 | 2 | EA |
656 | 6560 | 8 M pole with cantilever arrangement for mounting of 1 fixed camera at 6m and LED flood light at 8m of the pole across perimeter as per tender | 6560 | 50 | EA |
657 | 6570 | 4/6 M pole with Accessories as per specification of Tender | 6570 | 9 | EA |
658 | 6580 | Installation, configuration, integration, testing and commissioning of rack mounted CCTV Server (s) along with rack type monitor, optical mouse and combo 4 port KVM switch, OS, Antivirus, LIU etc complete as per specifications and Tender Document. \nNote: In case multiple servers are required to meet the tender requirement, vendor to provide the same at no additional cost to IOCL. In additional to above, Vendor to provide failover server to have redundancy in CCTV server such that failure of one server should not affect the CCTV operation and recording at its full resolution at no additional cost to IOCL. | 6580 | 1 | LS |
659 | 6590 | Installation, configuration, integration, testing and commissioning of Network Attached Storage ( NAS ) / Storage Attached Network (SAN) for storing recorded video for a minimum period 90 days @ 15 FPS at full resolution & highest Video quality of all cameras (Continuous recording) complete as per specifications and Tender Document. | 6590 | 500 | TB |
660 | 6600 | Installation, configuration, integration, testing and commissioning of CCTV client work station along with client software & licenses, key board, mouse, hardware & connector for repeat/ Dual display on wall mounted LED screen, OS, Antivirus, etc complete as per specifications and Tender Document.\n\nNote: CCTV Work station shall have provision to connect to 2 nos. of UHD LED monitors . Required hardware & software is to be provided for the same. Incase the offered work station do not have such provision, then additional work station to be provided meeting the tender requirement at no additional cost to IOCL.Marketing CPU for control room & security room shall be kept in Panel room in 42 U Rack. KVM extender & reciever for these CPU is to be supplied at no additional cost. | 6600 | ||
661 | 6610 | Rack type (2 U) with minimum 27" colored LED monitor :- Control Room - 1 no. ,Security Room - 1no.(CPU to be kept in Mkt. panel room) | 6610 | 2 | EA |
662 | 6620 | Tower type without Monitor :- Mkt. TM room - 1 No. , Pipeline TM room - 1 No., Pipeline CR room - 1 No. | 6620 | 3 | EA |
663 | 6630 | Installation,commissioning & integration of video wall along with required controller & complete accecories , cables etc , mounting arrangement from wall/ceiling for fire fighting cum critical Alarm display & annuniciation cum CCTV application complete as per specifications and tender document. \nIn control room:-Windows for all cameras should be available on single screen of 300-400 cm2 for min. 150 no. CCTV camera.\n\nNote: Two Number (min. 55” each or meeting size of video wall) for Alarm LED display and Fire fighting display along with one no. of hooter with provision of dual tone sound,ack push button & accessories. | 6630 | 6 | EA |
664 | 6640 | Installation, commissioning & integration of video wall along with controller & complete accecories , cables etc. for CCTV complete as per specifications and tender document. \nIn location in charge room:-viewing window size should be preferably be between 250-300 cm2 ( in two pages) for CCTV camera. | 6640 | 2 | EA |
665 | 6650 | Installation, commissioning & integration of video wall along with controller & complete accecories , cables etc. for CCTV complete as per specifications and tender document. \nIn security cabin:-viewing window size should be preferably be between min. 150-200 cm2 ( in two pages) for CCTV camera. | 6650 | 2 | EA |
666 | 6660 | Installation, integration, configuration, testing and commissioning of Layer 3 Managed Gigabit Ethernet Switch with minimum 24 ports or as per site requirement + 20 % spare whichever is higher along with SFP, copper, fibre modules, accessories complete as per specifications and Tender Document. \nNote- The switches are required to be configured in dual redundant mode \n | 6660 | 2 | EA |
667 | 6670 | Installation, integration, configuration, testing and commissioning of Intelligent video operation, control, management, recording & processing software (VMS) complete as per specifications and Tender Document with minimum 125 cameras recording, 125 cameras viewing license, 5 LISC licence for remote viewing or as per actual nos. of cameras installed + 20% extra which ever is higher. | 6670 | 1 | LS |
668 | 6680 | Installation, integration, configuration, testing and commissioning of Advanced Analytics Software for all fixed cameras (including varifocal, MFZ fixed cameras), Auto tracking video analytics for all PTZ camera along with compatible Redundant Analytics Server with OS, Antivirus etc including analytic license for actual number of camera installed + 20 % spare complete as per specifications and Tender Document. | 6680 | 1 | LS |
669 | 6690 | Installation, testing and commissioning of 350 W LED flood ONLY light luminaries on Light poles up to 10M height including supply & fixing of clamps, scafolding , temporary fire screen ifrequired, supports, nuts,bolts, earthing , required modification infixing arrangement , Supply and welding of mounting structure as persite condition , painting etc. all complete with labour and materials asper drawings, specifications and directions of the Engineer-in-Charge. | 6690 | 58 | EA |
670 | 6700 | Installation, integration, configuration, testing and commissioning of IP Fixed Bullet cameras with IR MFZ lens (8MP) – 4K resolution along with power supply unit (POE based), with inbuilt/external surge protection unit and mounting accessories etc complete as per specifications and Tender Document.(TT Reporting :-2+TTEntry/Exit:-2+Driver Entry/Exit-2,Helper Entry/Exit-2, Photo Pass issuance:- 2) | 6700 | 10 | EA |
671 | 6710 | Miscellaneous | 6710 | ||
672 | 6720 | Installation, integration, configuration, testing and commissioning of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, isolation valve, Aluminium canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated else where in tender).\nNote:1. Pressure transmitter at suction shall have range from -1 Kg/cm2.\n2. Underground tank shall have PT in Pump discharge end only. | 6720 | ||
673 | 6730 | TLF pump Suction end | 6730 | 11 | EA |
674 | 6740 | TLF pumps Discharge end | 6740 | 11 | EA |
675 | 6750 | MS, HSD, Transmix, Ethanol Tanks Sprinkler & Foam Line | 6750 | 24 | EA |
676 | 6760 | Fire Hydrant lines (Fire Hydrant Header-2+Fire Hydrant line-2+Foam Pump-2) | 6760 | 6 | EA |
677 | 6770 | Sludge/Stripping Pumps suction end---Remote Seal Type | 6770 | 6 | EA |
678 | 6780 | Sludge/Stripping Pumps discharge end---Remote Seal Type | 6780 | 6 | EA |
679 | 6790 | Underground tank's pump discharge end | 6790 | 6 | EA |
680 | 6800 | Installation, integration, configuration, testing and commissioning of flameproof cum weather proof to IP 65 or better SIL 2 Smart Differential pressure transmitter with in built display, SS 3 way manifold, Aluminium canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated else where in tender) | 6800 | ||
681 | 6810 | Across TLF pump Strainers | 6810 | 11 | EA |
682 | 6820 | Across Sludge/Stripping Pumps Strainers---Remote Seal Type | 6820 | 6 | EA |
683 | 6830 | Decentation line | 6830 | 2 | EA |
684 | 6840 | Installation, integration, configuration, testing and commissioning of flameproof cum weather proof to IP 65 or better bi-colour magnetic flap type level gauge (side mounted) along with level transmitter with installed accuracy +/- 6 mm or better along with mounting accessories, complete as per specification and tender document. | 6840 | ||
685 | 6850 | Foam (Daughter+Mother) Tanks for HVLR | 6850 | 10 | EA |
686 | 6860 | Fire Engine Service tanks | 6860 | 6 | EA |
687 | 6870 | DG Set Service Tanks | 6870 | 3 | EA |
688 | 6880 | Installation, integration, configuration, testing and commissioning of Level switch ( Magnetic Float / displacer type ) for low and high level alarm along with mounting accessories etc as per specifications | 6880 | ||
689 | 6890 | Fire water Sump | 6890 | 1 | EA |
690 | 6900 | TT calibration sump | 6900 | 1 | EA |
691 | 6910 | Treater water Tank + Service water | 6910 | 2 | EA |
692 | 6920 | Raw water sump | 6920 | 1 | EA |
693 | 6930 | Installation, integration, configuration, testing and commissioning of Wailing siren along with controller with a provision to operate locally as well as from control room, mounting accessories etc complete as per specification and tender document. | 6930 | 1 | EA |
694 | 6940 | Installation, integration, configuration, testing and commissioning of Digital Rodent Repellent System along with mounting accessories for main controller(s) & transducers etc complete as per specification and tender document (Minimum nos of transducers: Control Room - 12 nos., S & D Room - 4 Nos., Invoice room - 4 nos. & Security Room - 4 nos.) | 6940 | 1 | LS |
695 | 6950 | Installation, integration, configuration, testing and commissioning of Ex-proof and weather proof Hooter cum Beacons along with accessories, mounting structure etc complete as per specification and tender document for audio visual alarm at field in case the MOVs installed at tank dyke drain and tank water draw off line is not fully closed.\nLocation : Near each tank dyke and to be installed outside dyke. | 6950 | 7 | EA |
696 | 6960 | Installation, integration, configuration, testing and commissioning of Solenoid valves (SOV) of 25 /32/50/65 NB (as per line size) along with one no. of isolation by pass valve to bypass the SOV with associated piping, mounting accessories etc complete as per specification and tender document. \nNote: SOV need to be supplied factory fitted along with baypass valve and both side flanged option.For Ethanol tank's HVLRs SOV is not required. | 6960 | ||
697 | 6970 | At the inlet of DG set Service tanks | 6970 | 3 | EA |
698 | 6980 | At the inlet of Fire Engine Service tanks | 6980 | 6 | EA |
699 | 6990 | At the inlet of HVLR tanks | 6990 | 6 | EA |
700 | 7000 | Installation, testing and commissioning of MCT block for entire Automation cable entry to Control Room, Admin Building, Invoice Room, Security Room, Customer service room, Driver's Rest Room with minimum 30% spare MCT blocks for future cable entry along with frame and mounting accessories complete as per specification and tender document. | 7000 | 1 | LS |
701 | 7010 | Installation,testing and commissioning of external surge & Lightening protection devices of suitable connector and type along with accessories complete as per specification and tender document at following places. | 7010 | ||
702 | 7020 | SPD (Type 2 / IC category C1,C2,C3,D1) - Serial port of MCS (RJ45 type) & Terminal Server | 7020 | 42 | EA |
703 | 7030 | Type 1 SPD - Earth pit | 7030 | 10 | EA |
704 | 7040 | Installation, integration, configuration, testing and commissioning of Magnetic flow meter of 65 NB along with two no. SS ball valve along with bypass valve with associated piping and mounting accessories etc complete as per specification and tender document. | 7040 | 1 | EA |
705 | 7050 | Installation, integration, configuration, testing and commissioning of Turbine Flow Meter (40/50 MM) with pulse transmitter and field totalizer unit in n Flameproof and Weather Proof (Min. IP 65) enclosure along with two number of SS ball valve, strainer cum aireliminter (50 mm) and associated piping as tender specification and mounting accessories complete as per specification and tender document. \nNote: For HSD Meaurement to pipeline division/LPG. | 7050 | 2 | EA |
706 | 7060 | Cabling, JB, Earthing: | 7060 | ||
707 | 7070 | Note: laying, glanding, ferruling, termination of cables shall be along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), LAN face plates, conduits, structural steel for mounting of equipments, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc | 7070 | ||
708 | 7080 | Laying, glanding, ferruling, termination of FRLS Armoured Copper Power cable as per tender specifications. | 7080 | ||
709 | 7090 | 3C x 2.5 sqmm | 7090 | 12600 | M |
710 | 7100 | 4C x 2.5 sqmm | 7100 | 2200 | M |
711 | 7110 | 8C x 2.5 sqmm | 7110 | 4800 | M |
712 | 7120 | 10C x 2.5 sqmm | 7120 | 3800 | M |
713 | 7130 | 12C x 2.5 sqmm | 7130 | 2200 | M |
714 | 7140 | 24C x 2.5 sqmm | 7140 | 3600 | M |
715 | 7150 | 3C x 4 sqmm | 7150 | 6000 | M |
716 | 7160 | 4C x 4 sqmm | 7160 | 2400 | M |
717 | 7170 | 4C x 6 sqmm | 7170 | 100 | M |
718 | 7180 | 4C x 10 sqmm | 7180 | 100 | M |
719 | 7190 | Laying, glanding, ferruling, termination of FRLS Armoured Aluminium Power cable as per tender specifications. | 7190 | ||
720 | 7200 | 3.5C x 120 sqmm | 7200 | 600 | M |
721 | 7210 | Laying, glanding, ferruling, termination of FRLS Armoured Copper Control cable as per tender specifications. | 7210 | ||
722 | 7220 | 2C x 1.5 sqmm | 7220 | 12000 | M |
723 | 7230 | 3C x 1.5 sqmm | 7230 | 1000 | M |
724 | 7240 | 4C x 1.5 sqmm | 7240 | 8000 | M |
725 | 7250 | 6C x 1.5 sqmm | 7250 | 3000 | M |
726 | 7260 | 8C x 1.5 sqmm | 7260 | 3000 | M |
727 | 7270 | 10C x 1.5 sqmm | 7270 | 2000 | M |
728 | 7280 | 12C x 1.5 sqmm | 7280 | 5000 | M |
729 | 7290 | 16C x 1.5 sqmm | 7290 | 1000 | M |
730 | 7300 | 18C x 1.5 sqmm | 7300 | 4000 | M |
731 | 7310 | 20C x 1.5 sqmm | 7310 | 1000 | M |
732 | 7320 | 24C x 1.5 sqmm | 7320 | 3500 | M |
733 | 7330 | 32C x 1.5 sqmm | 7330 | 1000 | M |
734 | 7340 | 36C x 1.5 sqmm | 7340 | 1200 | M |
735 | 7350 | 48C x 1.5 sqmm | 7350 | 5500 | M |
736 | 7360 | Laying, glanding, ferruling, termination of FRLS Armoured Copper Signal cable as per tender specifications. | 7360 | ||
737 | 7370 | 1P x 1.5 sqmm | 7370 | 12000 | M |
738 | 7380 | 2P x 1.5 sqmm | 7380 | 8500 | M |
739 | 7390 | 3P x 1.5 sqmm | 7390 | 2400 | M |
740 | 7400 | 4P x 1.5 sqmm | 7400 | 900 | M |
741 | 7410 | 6P x 1.5 sqmm | 7410 | 2500 | M |
742 | 7420 | 8P x 1.5 sqmm | 7420 | 1500 | M |
743 | 7430 | 10P x 1.5 sqmm | 7430 | 1000 | M |
744 | 7440 | 12P x 1.5 sqmm | 7440 | 5500 | M |
745 | 7450 | 16P x 1.5 sqmm | 7450 | 1200 | M |
746 | 7460 | 18P x 1.5 sqmm | 7460 | 1500 | M |
747 | 7470 | 1T x 1.5 sqmm | 7470 | 1200 | M |
748 | 7480 | 8T x 1.5 sqmm | 7480 | 2500 | M |
749 | 7490 | Laying, glanding, ferruling, termination of FS Armoured Copper Power cable as per tender specifications. | 7490 | ||
750 | 7500 | 3C x 2.5 sqmm | 7500 | 8000 | M |
751 | 7510 | 3C x 4 sqmm | 7510 | 1800 | M |
752 | 7520 | 4C x 2.5 sqmm | 7520 | 1200 | M |
753 | 7530 | 4C x 4 sqmm | 7530 | 1400 | M |
754 | 7540 | Laying, glanding, ferruling, termination of FS Armoured Copper Control cable as per tender specifications. | 7540 | ||
755 | 7550 | 2C x 1.5 sqmm | 7550 | 5800 | M |
756 | 7560 | 3C x 1.5 sqmm | 7560 | 100 | M |
757 | 7570 | 4C x 1.5 sqmm | 7570 | 2000 | M |
758 | 7580 | 6C x 1.5 sqmm | 7580 | 4200 | M |
759 | 7590 | 8C x 1.5 sqmm | 7590 | 4600 | M |
760 | 7600 | 10C x 1.5 sqmm | 7600 | 1000 | M |
761 | 7610 | 12C x 1.5 sqmm | 7610 | 2400 | M |
762 | 7620 | 18C x 1.5 sqmm | 7620 | 1000 | M |
763 | 7630 | 24C x 1.5 sqmm | 7630 | 3000 | M |
764 | 7640 | 32C x 1.5 sqmm | 7640 | 1500 | M |
765 | 7650 | 36C x 1.5 sqmm | 7650 | 1000 | M |
766 | 7660 | 48C x 1.5 sqmm | 7660 | 2500 | M |
767 | 7670 | Laying, glanding, ferruling, termination of FS Armoured Copper Signal cable as per tender specifications. | 7670 | ||
768 | 7680 | 1P x 1.5 sqmm | 7680 | 7000 | M |
769 | 7690 | 2P x 1.5 sqmm | 7690 | 5800 | M |
770 | 7700 | 3P x 1.5 sqmm | 7700 | 3200 | M |
771 | 7710 | 4P x 1.5 sqmm | 7710 | 5000 | M |
772 | 7720 | 1T x 1.5 sqmm | 7720 | 3200 | M |
773 | 7730 | laying, glanding, ferruling, termination of 6 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge. | 7730 | 7000 | M |
774 | 7740 | laying, glanding, ferruling, termination of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge. | 7740 | 4000 | M |
775 | 7750 | laying, glanding, ferruling, termination of Pre fab CAT 6 Ethernet un-armoured cable as per tender specifications and instructions of Engineer in charge. | 7750 | ||
776 | 7760 | 5/10 m | 7760 | 150 | EA |
777 | 7770 | 15 m | 7770 | 50 | EA |
778 | 7780 | 20 m | 7780 | 40 | EA |
779 | 7790 | 25 m | 7790 | 25 | EA |
780 | 7800 | 30 m | 7800 | 25 | EA |
781 | 7810 | laying, glanding, ferruling, termination of 1C x 6 Sq. mm FRLS Flexible copper insulated green wire for earthing instruments and junction boxes etc complete as per specification and tender document | 7810 | 25000 | M |
782 | 7820 | Fabrication , cutting , laying & connection of GI strip ( 50mm X 6mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. | 7820 | 4000 | M |
783 | 7830 | Fabrication , cutting , laying & connection of GI strip ( 25mm X 3mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. | 7830 | 2000 | M |
784 | 7840 | Laying of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents. | 7840 | ||
785 | 7850 | 50 mm | 7850 | 8000 | M |
786 | 7860 | 100 mm | 7860 | 6500 | M |
787 | 7870 | 150 mm | 7870 | 4500 | M |
788 | 7880 | 300 mm | 7880 | 4000 | M |
789 | 7890 | 600 mm | 7890 | 1000 | M |
790 | 7900 | Installation of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents. | 7900 | ||
791 | 7910 | 24 ways JB | 7910 | 30 | EA |
792 | 7920 | 18 ways JB | 7920 | 35 | EA |
793 | 7930 | 12 ways JB | 7930 | 40 | EA |
794 | 7940 | 8 ways JB | 7940 | 60 | EA |
795 | 7950 | 6 ways JB | 7950 | 60 | EA |
796 | 7960 | 4 ways JB | 7960 | 60 | EA |
797 | 7970 | Laying of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge. | 7970 | 1500 | M |
798 | 7980 | Design, fabrication, painting & errection of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc | 7980 | 30 | TO |
799 | 7990 | Earth Pit | 7990 | ||
800 | 8000 | Installation, testing and commisioning of Maintenance Free CPRI approved Earth pit ( Ashlok /Equivalent make ) as per IS : 3043 with 100 mm dia of minimum 3mtr length safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Procedure recommended by chemical earth supplier and IS code to be finally adopted. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation.\nAll Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification) | 8000 | ||
801 | 8010 | TLF gantry | 8010 | 2 | EA |
802 | 8020 | TT earthing | 8020 | 6 | EA |
803 | 8030 | Control room | 8030 | 6 | EA |
804 | 8040 | Tank farm | 8040 | 10 | EA |
805 | 8050 | Pump house | 8050 | 4 | EA |
806 | 8060 | CCTV | 8060 | 16 | EA |
807 | 8070 | SIL VERIFICATION / VALIDATION | 8070 | ||
808 | 8080 | SIL verification from approved third party agencies. (For SIFs as per SIL Assessment study report/detail engg). All required documentation as per specs and other documentation mentioned elsewhere in tender scope has to be submitted. Complete as per specification / tender documents. | 8080 | 1 | LS |
809 | 8090 | Validation of entire Safety System (SIS) for SIFs (for e.g. AOPS -SIF) shall be carried out from approved third party agency prior to trial period. Automation contractor shall bear the responsibility of its co-ordination and logistics. The third party has to submit a detailed report along with certification for SIS which is to be approved by IOCL along with all other required documentation as per specification and tender documents. | 8090 | 1 | LS |
810 | 8100 | Services for Safety Instrumented System testing after installation in presence of safety, operation and engg. Team from user. Demonstration of safety system during pre OISD / OISD & statutory audits & there after periodic testing. Complete as per specifications / tender documents. | 8100 | 1 | EA |
811 | 8110 | OTHER SERVICES | 8110 | ||
812 | 8120 | Providing training to IOCL employee as per schedule/Module for 2 days as per tender document | 8120 | 1 | Module |
813 | 8130 | Submission of detailed system design, Engineering, Documentations etc as per tender document | 8130 | 1 | LS |
814 | 8140 | Submission of Final Detailed system design, Engineering, Documentations, as built drawings etc complete as per tender | 8140 | 1 | LS |
815 | 8150 | Resident Engineer support on quarterly basis in case of shift addition during CAMC period | 8150 | 1 | EA |
816 | 8160 | Design, development, modification, configuration, testing and commissioning of existing TAS software, DCS/PLC logic, GUI etc for implementation of following features after FAT (if required) or during CAMC period as stated in tender document. The job includes necessary tro-& fro travel, lodging, boarding, food etc required for implementation at site complete in all respect and as per direction of EIC. | 8160 | ||
817 | 8170 | Loading point addition | 8170 | 1 | per LP |
818 | 8180 | Product pump addition | 8180 | 1 | per pump |
819 | 8190 | Product tank addition | 8190 | 1 | per tank |
820 | 8200 | Product code change | 8200 | 1 | per product code |
821 | 8210 | SUB TOTAL (II) - SERVICE COMPONENTS (excluding GST) | 8210 | ||
822 | 8220 | Comphrehensive AMC - PART -III | 8220 | ||
823 | 8230 | Comprehensive Annual Maintenance Contract for a period of Seven years for entire Terminal Automation System after successful completion of SAT as described in Technical Bid. \nCost of all the required spares, hardwares, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, calibration of instruments, proving & stampings of metering equipments, rectification/ replacement of faulty TAS equipment etc required for running and maintenance of the entire Terminal Automation System to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor. \nThe scope also includes posting of Resident Engineer (s) to take care of running and maintenance of the entire Automation System complete as per the tender document. | 8230 | ||
824 | 8240 | First Year @4% of the basic CAPEX cost | 8240 | 1 | LS |
825 | 8250 | Second Year @4% of the basic CAPEX cost | 8250 | 1 | LS |
826 | 8260 | Third Year @7% of the basic CAPEX cost | 8260 | 1 | LS |
827 | 8270 | Fourth Year @7% of the basic CAPEX cost | 8270 | 1 | LS |
828 | 8280 | Fifth Year @10% of the basic CAPEX cost | 8280 | 1 | LS |
829 | 8290 | Sixth Year @6% of the basic CAPEX cost | 8290 | 1 | LS |
830 | 8300 | Seventh Year @12% of the basic CAPEX cost | 8300 | 1 | LS |