| Name of Work: Re-Construction of 2 No. Class Rooms with Verandah, Toilet Block, Septic Tank, Soak Pit in Govt. Primary School Jabran, in Poonch District under Jhelum-Tawi Flood Recovery Project (JTFRP (World Bank Funding). | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Dismantling CGI Roofing including Ridges, hips, valley & gutter etc & stocking the material with 50 Mtr lead. (SSR 2012 Code No.15.28.1) | 132 | Sqm | |
| 2 | 2 | Dismantling woodwork in frames, trusses.purlins, Rafter etc 10.00 Mtrs & 5.0 Mtrs height including stocking the material upto stocking 50 Mtr lead. (SSR 2012 Code No.15.14.1) | 2.43 | Cum | |
| 3 | 3 | Demolishing stone rubble Masonary by Manual means including Stockings of Serviceable material & disposable of unserviceable material upto 50.00 Mtrs lead. (SSR 2012 Code No 15.9.2) | 62.08 | Cum | |
| 4 | 4 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead: 1:3:6 or richer mix . (SSR 2012 Code No.15.2.1) | 0.68 | Cum | |
| 5 | 5 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: of area beyond 3 sq. metres (SSR 2012 Code No.15.13.2) | 4 | Each | |
| 6 | 6 | Disposal of excess Mulba from site by manual/mechanical means ( SSR-2012 Code 1.1.6) | 37 | Cum | |
| 7 | 7 | Earthwork in all kinds of soil excavation by manual means in trenches for foundations, drains, pipes, cable etc. (not exceeding 1.5 in width) and for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to be levelled and neatly dressed. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 2.8).\n | 176 | Cum | |
| 8 | 8 | Providing & laying in Position cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded crushed stone aggregate 40mm excluding the cost of centering and shuttering. All works upto plinth level. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 4.5.10). | 3 | Cum | |
| 9 | 9 | Providing & laying in Position cement concrete 1:4:8 (1 cement : 4 fine sand : 8 graded crushed stone aggregate 40mm excluding the cost of centering and shuttering. All works upto plinth level. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 4.5.9). | 20 | Cum | |
| 10 | 10 | Providing and laying in position cement concrete of 1:3:6 grade (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) excluding the cost of centering and shuttering. All work upto plinth level.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 4.5.5).\n | 50 | Cum | |
| 11 | 11 | Providing and laying in position 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement. All work up to plinth level using crushed aggregate.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.1.2).\n | 9 | Cum | |
| 12 | 12 | Providing and laying Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) in suspended floors, balconies, landings and staircases having 15 degree slope. upto floor five level excluding the cost of centering and shuttering.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.50).\n | 76 | Cum | |
| 13 | 13 | Providing and laying in position cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) excluding cost of centering and shuttering. All work upto plinth level.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 4.5.3).\n | 15 | Cum | |
| 14 | 14 | Providing and laying Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) in suspended floors, balconies, landings and staircases having 15 degree slope. upto floor five level excluding the cost of centering and shuttering.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.50).\n | 76 | Cum | |
| 15 | 15 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT bars.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.22.7).\n | 7947 | Kg | |
| 16 | 16 | Centering and shuttering including strutting, propping etc. and removal of form work for :- | |||
| 17 | 16.01 | Foundations, footings, bases of columns.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.1).\n | 135 | Sqm | |
| 18 | 16.02 | Suspended floors, roofs, landings, balconies and access platforms.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.3).\n | 160 | Sqm | |
| 19 | 16.03 | Columns, pillars, piers, abutments, posts and struts. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.6).\n | 87 | Sqm | |
| 20 | 16.04 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.5). | 145 | Sqm | |
| 21 | 16.05 | Edges of slabs and breaks in floors and walls upto 20cm wide. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.16.1). | 189 | Rmt | |
| 22 | 17 | Brick work with common burnt clay F.P.S (non modular) bricks of class designation 75 in foundation & plinth in cement mortar 1:4 (1 cement : 4 course sand). \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 6.1.7). | 10 | Cum | |
| 23 | 18 | Brick work with common burnt clay F.P.S (non modular) bricks of class designation 75 in foundation & plinth in cement mortar 1:6 (1 cement : 6 coarse sand). \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 6.1.8). | 65 | Cum | |
| 24 | 19 | Extra for brick work in super structure above plinth level upto floor V-level. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 6.2). \n | 23 | Cum | |
| 25 | 20 | Half brick masonry with bricks of class designation 75 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand).\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 6.14.2).\n | 23 | Sqm | |
| 26 | 21 | Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 2.22).\n | 22 | Cum | |
| 27 | 22 | Supply and filling of brick aggregate under floor with 1:5:10 mix with 40mm stone agg. including compacting the same manually with all leads and lifts carriage complete. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.49).\n | 6 | Cum | |
| 28 | 23 | 6mm thick cement plaster to ceiling of mix 1:3 (1 cement : 3 fine sand).\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 13.17).\n | 169 | Sqm | |
| 29 | 24 | 12mm cement plaster of mix 1:6 (1 cement : 6 fine sand).\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 13.1.2).\n | 204 | Sqm | |
| 30 | 25 | 12mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand).\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 13.7.2). \n | 60 | Sqm | |
| 31 | 26 | 15mm cement plaster on the rough side of single or half brick wall of mix in 1:4 (1 cement : 4 coarse sand). \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 13.5.2).\n | 107 | Sqm | |
| 32 | 27 | 15mm cement plaster on the rough side of single or half brick wall of mix in 1:6 (1 cement : 6 coarse sand). \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 13.5.2).\n | 566 | Sqm | |
| 33 | 28 | Brick edging 7cm wide 11.4cm deep of plinth protection with bricks incl.grouting with cement mortar 1:4..(SSR 2012 Code No.6.38) | 100 | Rmt | |
| 34 | 29 | P/F M.S grills of required pattern in frames of windows,railings etc.with M.S flat,square or round bars etc. incl.priming coat with approved steel primer all complete job fixed to openings/wooden frames with rawl plugs screws etc..(SSR 2012 Code No.9.43) | 119 | Kg | |
| 35 | 30 | 50mm thick Cement concrete flooring 1:2:4 finished with a floating coat of neat cement slurry, but excluding the cost of nosing of steps etc.complete(SSR 2012 Code No.11.4.3) | 175 | Sqm | |
| 36 | 31 | P/F glass strips in joints of terrazzo/cement concrete flooring 40mm wide and 4mm thick.(SSR 2012 Code No.11.18.1) | 137 | Rmt | |
| 37 | 32 | Making plinth protection 50mm thick cement concrete 1:3:6 (1 cement : 3 course sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth crushed. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 4.22).\n | 34 | Sqm | |
| 38 | 33 | Painting top of roofs with bitumen of approved quality at 17 Kg per 10 Sqm impregnated with a coat of course sand at 60cum per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete with residual type petroleum bitumen of penetration 80/100. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 12.17). | 165 | Sqm | |
| 39 | 34 | 10cm thick (average) mud phuska of damped brick earth on roofs laid to slope consolidated and plastered with 25mm thick mud mortar mixed with bhusa at 35Kg/Cum of earth and gobri leaping with bhusha at 35kg/cum of earth and gobri leaping with mix 1:1 (1clay : 1cow dung) and covered with flat tile bricks of class designation 100 grouted with cement mortar 1:3 (1cement : 3fine sand) mixed with 2% of internal water proofing compound by weight of cement and finished neat with hand moulded F.P.S brick tiles.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 12.26).\n | 165 | Sqm | |
| 40 | 35 | Providing gola 75 x 75mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75 x 75 mm deep chase.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 12.30).\n | 79 | Rmt | |
| 41 | 36 | Making khurras 45 x 45cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 12.31).\n | 6 | Nos | |
| 42 | 37 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 110mm diameter.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 12.57.2). | 24 | Rmt | |
| 43 | 38 | P/F on wall face unplastisized Rigid Bend Type A incl. jointing with seal ring leaving gap for thermal expansion single socketed pipes 110mm diameter..(SSR 2012 Code No.12.58) | 14 | Nos | |
| 44 | 39 | Filling available excavated earth in trenches,plinth etc. in layers not exceeding 20cm in depth by way of ramming.watering lead upto 50m & lift 1.5m..(SSR 2012 Code No.2.46) | 49 | Cum | |
| 45 | 40 | Banking excavated earth in trenches,plinth etc. in layers not exceeding 20cm in depth,breaking clods by way of ramming.watering lead upto 50m & lift 1.5m..(SSR 2012 Code No.2.3) | 162.95 | Cum | |
| 46 | 41 | Steel work welded in built up sections incl.cutting,hoisting,fixing in Frames..(SSR 2012 Code No.10.32.2) | 875 | Kg | |
| 47 | 42 | Providing Wood wrok in frames of doors,windows clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter and length (holf fast lugs or with dash fastners shall be paid seperately SAL WOOD. (Refers SSR - 2012 Code 9.1.17 | 1.39 | Cum | |
| 48 | 43 | Providing 40x5mm flat iron holdfast 40cm long incl.fixing to frame with 10mm diameter bolts,nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm in 1:3:6 mix. .(SSR 2012 Code No.9.48) | 56 | Nos | |
| 49 | 44 | Providing and fixing 35mm thick factory made laminated veneer lumber door shutter conforming to IS – 14616 and TADS 15 : 2001 (part-B) including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer – in charge and paneling with panels of 12mm thick one side pre-laminated particle board (decorative lamination on one sides and other side balancing lamination) grade-1, medium density flat pressed three layer particle board FPT-I like or graded wood particle board FPT-I conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-lamination conforming to IS : 12823 Grade-1, Type II marked.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.4.A.3).\n | 5 | Sqm | |
| 50 | 45 | P/F 35mm thick Panelled & glazed door shutters for doors & windows incl. M.S pressed butt hinges bright finished required size with necessary screws excl.paneling which will be paid separetely all complete as per directions of Engineer in charge of 2nd class deodar wood..(SSR 2012 Code No.9.4.3) | 10 | Sqm | |
| 51 | 46 | Providing and fixing paneling of plain particle board flat pressed, 3 layers (like Nova pan, Eco board etc.) or graded wood particle board (like Bhutan Board) medium density Grade I, IS : 3087 marked for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Paneling for paneled or paneled and glazed shutters 25mm to 40mm thick. Plain particle board flat pressed, 3 layers (like Novapan, Ecoboard etc.) or graded wood particle board (like bhutan board) medium density grade I, IS 3087 marked. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.5.9.1). | 7 | Sqm | |
| 52 | 47 | Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauge of average width for aperture 1.4mm in both direction with wire of dia 0.63mm for doors, windows and clerestory windows with hinges and necessary screws in second class deodar wood.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.22.1.3).\n | 24 | Sqm | |
| 53 | 48 | Providing & fixing glazed shutters 35mm thick for doors, windows and clear story windows using 10Kg/Sqm (4mm thick) glass panes including black enameled ISI marked M.S. butt hinges with necessary screws in second class deodar wood.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.6.3).\n | 16 | Sqm | |
| 54 | 49 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluded fixing accessories such as nuts, bolts, fasteners etc. | 30 | RFT | |
| 55 | 50 | Providing and fixing cup board shutters 25mm thick, with pre-laminated flat pressed three layer particle board or graded wood particle board IS : 12823 marked exterior grade (Grade-I, Type-II) having one side decorative lamination and other side a balancing lamination including second class teak wood lipping of 25mm wide x 12mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of Engineer-in-charge.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.134).\n | 10 | Sqm | |
| 56 | 51 | P/F 30mm thick of 2nd class deodar wood glazed shutter for doors,windows etc. using 10kg/sqm float glass panes incl. M.S butt hinges of required size with necessary screws etc.complete. .(SSR 2012 Code No.9.6.3) | 22 | Sqm | |
| 57 | 52 | Finishing walls with textured exterior paint of required shade on new work (two or more coats @ 3.28 ltr/10 Sqm over and incl.base course of water proofing cement paint applied @ 2.20 Kg/10 Sqm (SSR 2012 Code No.13.89) | 164 | Sqm | |
| 58 | 53 | Providing and applying white cement based putty of average thickness 2mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 13.101).\n | 913 | Sqm | |
| 59 | 54 | Finishing walls with Water proofing cement paint of required shade on new work Two or more coats..(SSR 2012 Code No.13.55.1) | 341 | Sqm | |
| 60 | 55 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade new work (two or more coats) over and including priming coat with cement primer. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 13.52.1).\n | 473 | Sqm | |
| 61 | 56 | Applying priming coat with ready mixed Red oxide zinc chromate primer of approved brand and manuf.acture on steel galvanised iron/steel works..(SSR 2012 Code No.13.56.3) | 16 | Sqm | |
| 62 | 57 | Applying priming coat with ready mixed pink or grey of primer of approved brand and manufacture on wood work (hard and soft wood).\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 13.56.1). | 105 | Sqm | |
| 63 | 58 | Painting with synthetic enamel paint of approved brand and shade on new steel work(SSR 2012 Code No.13.57.1) | 30 | Sqm | |
| 64 | 59 | Painting with synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new work.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 13.69).\n | 43 | Sqm | |
| 65 | 60 | P/F ISI marked oxdised M.S sliding door bolts with nuts and screws etc.complete 250x16mm.(SSR 2012 Code No.9.95.2) | 8 | Nos | |
| 66 | 61 | Providing and fixing aluminium handles ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. | |||
| 67 | 61.01 | 125mm.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.99.1).\n | 31 | Nos. | |
| 68 | 61.02 | 100mm.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.99.2).\n | 28 | Nos. | |
| 69 | 62 | Providing and fixing aluminium tower bolts ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. | |||
| 70 | 62.01 | 250x10mm. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.96.2).\n | 5 | Nos. | |
| 71 | 62.02 | 200x10mm. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.96.3).\n | 132 | Nos. | |
| 72 | 62.03 | 110x10mm. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.96.5).\n | 10 | Nos. | |
| 73 | 63 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. comlete 250x16mm.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.57.2).\n | 7 | Nos. | |
| 74 | 64 | P/P on terrace polyethylene water storage tank with cover & suitable locking arrangements & making necessary holes for inlet,outlet & overflow pipes but without fittings & the bases support for tank.(SSR 2012 Code No.20.40) | 2000 | Ltre | |
| 75 | 65 | Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and amking good the wall. | |||
| 76 | 65.01 | 15mm dia nominal bore.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 20.2A.1).\n | 66 | Rmt | |
| 77 | 65.02 | 20mm dia nominal bore.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 20.2A.2).\n | 22 | Rmt | |
| 78 | 66 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 20mm dia nominal bore.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 20.3.3).\n\n | 24 | Rmt | |
| 79 | 67 | Providing and fixing G.I. pipes complete with G.I. fittings including cuting & making good the walls. 20mm dia nominal bore.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 20.2.1.2).\n\n | 10 | Rmt | |
| 80 | 68 | Providing and laying non-pressure NP2 class RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joint etc. complete 100mm dia RCC pipe.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 21.6.1).\n | 40 | Rmt | |
| 81 | 69 | Providing and fixing water closet squatting pan (Indian type W.C pan) with 100mm sand cast Iron P or S trap, 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required of Cera, Parryware, Hindware or equivalent make as approved by Engineer-in-charge White Vitreous China Orrisa patern W.C pan of size 580x440 with integral type foot rests. \n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.1.2).\n | 4 | Nos | |
| 82 | 70 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern with C.P. flush with fittings, C.I/M.S brackets 40mm bend dia flush bend over flow arrangement with special of standard make and mosquito type proof coupling of approved municipal design complete including painting of fittings and brackets cutting and making good the walls wherever required WC pan with ISI marked with solid plastic seat and lid with white vitreous china flushing cistern and C.P flush bend.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.3.2).\n | 4 | Nos | |
| 83 | 71 | Providing and fixing wash basin with C.I/M.S brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White vitreous china wash basin size 550x400mm with a single 15mm C.P. brass pillar taps.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.7.4).\n | 4 | Nos | |
| 84 | 72 | P/F white glazed fire clay kitchen sink of size 600x450x250mm with C.I brackets,C.P brass chain with rubber plug 40mm incl.painting etc. complete(SSR 2012 Code No.19.26.1) | 1 | Nos | |
| 85 | 73 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS : 8931. 15mm nominal bore Mark, ESS, Cazar or of equivalent make as approved by Engineer-in-charge.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 20.41).\n | 5 | Nos | |
| 86 | 74 | P/F C.P brass long nose bib cock of 15mm nominal bore etc.complete.(SSR 2012 Code No.20.42) | 2 | Nos | |
| 87 | 75 | P/F C.P stop cock(concealed) of 15mm nominal bore etc.complete.(SSR 2012 Code No.20.44) | 8 | Nos | |
| 88 | 76 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved make conforming to IS : 8931. 15mm nominal bore.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 20.45).\n | 8 | Nos | |
| 89 | 77 | Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fitting complete flexible pipe 32mm dia.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 19.28.2.1).\n | 4 | Nos | |
| 90 | 78 | P/F Unplasticised PVC connection pipe with brass union 30cm length(15mmnominal bore)(SSR 2012 Code No.20.13.1.1) | 4 | Nos | |
| 91 | 79 | Providing and fixing100mm sand cast iron grating for gully, floor or Nahani Trap.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 19.29).\n | 4 | Nos | |
| 92 | 80 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing. Rectangular shape 453 x 357mm (outer dimensions).\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 19.32.2).\n | 4 | Nos | |
| 93 | 81 | Constructing masonry chamber 30 x 30 x 50cm, inside with 75 class designation brick work in cement mortar 1:5 (1 cement : 5 fine sand) for stop cock, with C.I surface box 100 x 100 x 75mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design (Crushed).\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 20.24.1).\n | 6 | Nos | |
| 94 | 82 | Providing and fixing Ist quality ceramic glazed tiles conforming to IS : 13753 of minimum thickness 5mm of approved make like NITCO, ORIENT, SOMANY, KAJARIA, or equivalent make in all colour, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 11.66).\n | 30 | Sqm | |
| 95 | 83 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigment etc. complete (size of tile 60x60cm).\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 11.34.2).\n | 2 | Sqm | |
| 96 | 84 | Marble work gang saw cut for wall lining(veneer work) in C.M 1:3 incl. pointing with white C.M 1:2 with an admixture of pigment to match the marble shade(16mm thick)(SSR 2012 Code No.8.1.2.1) | 6 | Sqm | |
| 97 | 85 | Providing and fixing in position Pre-cast RCC manholes cover and frame of required shape and approved quality (HD-20) circular shape 560mm internal dia.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 21.19.3.1).\n | 2 | Nos. | |
| 98 | 86 | Making soak pit 2.5m diameter 3.0 meter deep with 45x45cm dry brick honey comb shaft with bricks of class designation 75 and S.W drain pipe 100mm diameter, 1.8 Mtr long complete as per standard design with F.P.S bricks.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 21.34).\n | 2 | Each | |
| 99 | 87 | Surface dressing of the ground including removing of grass vegetation & in-equalities not exceeding 15cm deep & disposal of rubbish by M.T with all leads & lifts complete.(SSR 2012 Code No.2.23) | 145 | Sqm | |
| 100 | 88 | Providing and Laying River bed material free from organic material mixed with coarse agg. In layers not exceeding 200mm thick incl.rolling with power road roller of 80-100 KN incl. all leads & lifts complete. | 34 | Sqm | |
| 101 | 89 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibrator compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge.\n(Refer J&K Sanctioned Schedule of Rates 2012, Item code 17.85).\n | 82 | Sqm | |
| 102 | 90 | Providing and Laying of good earth incl.carriage complete.(SSR 2012 Code No.18.2) | 135 | Cum | |
| 103 | 91 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure in the ratio 2:1 by volume flooding with water, dressing incl. removal of rubbish and surplus earth, of any with all leads and lifts. Holes 60cmdia & 60cm deep.(SSR 2012 Code No.18.14.2) | 38 | Nos. | |
| 104 | 92 | Supply and stacking of good earth at site including royalty and carriage complete.(SSR 2012 Code No.18.2) | 64 | Cum | |
| 105 | 93 | Spreading of manure or good earth in required thickness as per directions of officer incharge.(SSR 2012 Code No. 18.8 ) | 64 | Cum | |
| 106 | 94 | Supply and stacking of well decayed cowdung manure at site incl. royalty etc complete.(SSR 2012 Code No.18.25) | 12 | Cum | |
| 107 | 95 | Grassing with reflection no.1 grass incl. watering and maintenance of the lawn for 30days or more till the grass farms a thick lawn free from weeds and fit for mowing incl. supplying of good earth of needed (good earth shall be paid separately).(SSR 2012 Code No.18.10.4) | 330 | Sqm | |
| 108 | 96 | Planting of trees, 2 ft to 3 ft height, in poly bags incl. cost of tree. | 20 | Nos. | |
| 109 | 97 | Providing and Fixing M.S flat iron tree guard 60cm dia and 2m high above ground level formed of 4nos. 25x6mm riveted to 3nos. 25x6 mm Ms flat iron rings in two halves fixed together with required 6no. of with 8 mm dia. and 30mm long bolts incl. painting two coats with paint over a coat of primer. One name plate of 1mm thick M.S. Sheet of size 250x100mm shall be welded to the tree guard near the middle height.(SSR 2012 Code No.18.16) | 20 | Nos. | |
| 110 | 98 | Electrical Works :-\nWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Refer CPWD DSR E&M 2016 Item No. 1.10.1).\n | 44 | Nos. | |
| 111 | 99 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (Refer CPWD DSR E&M 2016 Item No. 1.12). | 34 | Mtrs | |
| 112 | 100 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Refer CPWD DSR E&M 2016 Item No. 1.14).\n | |||
| 113 | 100.01 | 2 x 1.5 sq. mm + 1 x 1.5 sq mm earth wire (1.14.1). | 34 | Mtrs | |
| 114 | 100.02 | 2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire (1.14.2). | 91 | Mtrs | |
| 115 | 100.03 | 2x10 Sqmm + 1x6 Sqmm earth wire ((CPWD DSR E&M 2016 Item No. 1.14.5) | 30 | Mtrs | |
| 116 | 101 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 1 x 2.5 sq. mm.\n(1.17.1) (Refer CPWD DSR E&M 2016 Item No. 1.17). \n | 48 | Mtrs | |
| 117 | 102 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required (for service line) 25mm. (Refer CPWD DSR E&M 2016 Item No. 1.21).\n | 25 | Mtrs | |
| 118 | 103 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (Refer CPWD DSR E&M 2016 Item No. 2.4). | |||
| 119 | 103.01 | 4 way (4+12), Double door (2.4.1). | 1 | Nos. | |
| 120 | 103.02 | 6 way (4 + 18), Double door (2.4.2). | 1 | No. | |
| 121 | 104 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Refer CPWD DSR E&M 2016 Item No. 1.24). | |||
| 122 | 104.01 | 5/6 A switch (1.24.1) | 10 | Nos. | |
| 123 | 104.02 | 3 pin 5/6 A socket outlet (1.24.4). | 10 | Nos. | |
| 124 | 105 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Refer CPWD DSR E&M 2016 Item No. 1.25). | 9 | Nos. | |
| 125 | 106 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (Refer CPWD DSR E&M 2016 Item No. 1.26). | 10 | Nos. | |
| 126 | 107 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.\n (Refer CPWD DSR E&M 2016 Item No. 1.32). | 2 | Nos. | |
| 127 | 108 | Supplying and fixing of following rating, 240/10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.\n(Refer CPWD DSR E&M 2016 Item No. 2.10). \n | |||
| 128 | 108.01 | Single Pole 6/16 amp. (2.10.1) | 10 | Nos. | |
| 129 | 108.02 | Single Pole and Neutral (2.10.2). | 1 | Nos. | |
| 130 | 109 | Installation testing and commissioning of wall bracket / ceiling fitting of all sizes and shapes contating upto two gls/cfl/led lamp per fitting complete with all accessories including connections etc. as required. (Refer CPWD DSR E&M 2016 Item No. 1.35).\n | 14 | Nos. | |
| 131 | 110 | Installation of exhaust fan in the existing opening including making good the damage,connection,testing,commissioning etc.as required.(CPWD DSR E&M 2016 Item No. 1.50).Upto 450mm sweep | 2 | Nos. | |
| 132 | 111 | Earthing with GI earth pipe 4.5 meter long 40 mm dia including accessories and providing measonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. (Refer CPWD DSR E&M 2016 Item No. 5.2). | 1 | Sets | |
| 133 | 112 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required. (Refer CPWD DSR E&M 2016 Item No. 5.18). | 6 | Mtrs | |
| 134 | 113 | Installation testing and commissioning of prewired flourescent fitting / compact flourescent fitting of all type complete with all accessories and tube/lamp etc. directly on ceiling/wall including connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. (Refer CPWD DSR E&M 2016 Item No. 1.41). | 12 | Nos. | |
| 135 | 114 | Installation testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable including providing and fixing of phenolic laminated sheet cover on the fan box etc. as required. (Refer CPWD DSR E&M 2016 Item No. 1.45). \n | 9 | Nos. | |
| 136 | 115 | Earthing with copper earth plate 600mm x 600mm x 3mm including accessories and providing measonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc with charcoal/coke and salt as required. (Refer CPWD DSR E&M 2016 Item No. 5.6). | 1 | Sets | |
| 137 | 116 | Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required. (Refer CPWD DSR E&M 2016 Item No. 5.19). | 10 | Mtrs | |
| 138 | 117 | Supplying and fixing of Angle/Baten Holder polycarbonate including making complete connnections etc as required. (Make as per annexure enclosed) (Refer CPWD DSR E&M 2016 Item No. 1.58). | 1 | Nos. | |
| 139 | 118 | Supplying and fixing of 9 watt LED Lamp. \n(Refer CPWD DSR E&M 2016 Item No. 1.59). | 7 | Nos. | |
| 140 | 119 | Supplying and fixing of following rating, 240/10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
| 141 | 119.01 | Single Pole and Neutral 40 amp. | 1 | Nos. | |
| 142 | 119.02 | Single Pole and Neutral 63 amp. | 1 | Nos. | |
| 143 | 120 | Supplying of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. \n Warranty two years from the date of installation \n | |||
| 144 | 120.01 | Ceiling Fan 1400 mm Sweep 5 Star rating. (Item No 6) | 9 | Nos. | |
| 145 | 120.02 | LED Ceiling light 12 watt (Item No 4) | 4 | Nos. | |
| 146 | 120.03 | LED Ceiling light 6 watt (Item No 3) | 4 | Nos. | |
| 147 | 120.04 | Bulk Head fitting suitable for out door use (Item No 2) | 6 | Nos. | |
| 148 | 120.05 | 1200 mm size 18/20 watt LED Batten Tube Light fitting. | 12 | Nos. | |
| 149 | 120.06 | Exhaust Fan 300mm (Heavy Duty) | 2 | Nos. | |
| 150 | 121 | Supplying and fixing of main service line 16 sqmm twin core aluminium cable unarmoured from the LT pole upto the MCB DB incluiding connections etc. as required. | 90 | Mtrs | |
| 151 | 122 | Supplying and fixing of 15 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet /wall etc as required. | 1 | Nos. | |
| 152 | 123 | Supplying and fixing of 30 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet /wall etc as required. | 2 | Nos. | |
| 153 | 124 | Fire Fighting System :-ABC Type Multi-purpose based Fire Extinguisher (ISO 9001) CE Marked applicable on all classes of fire (Capacity 6 Kgs). | 1 | Nos. | |
| 154 | 125 | CO2 based Fire Extinguisher (ISO 9001) CE Marked applicable on sensitive equipments (e.g. Electrical) Capacity 4.50 Kgs. | 1 | Nos. | |
| 155 | 126 | Fire Bucket (4 Nos.) with stand. | 1 | Nos. | |
| 156 | 127 | Drilling of 125 MM Dia Bore hole and installation of submersible pump including installation, testing and commissioning. | |||
| 157 | 127.01 | Drilling of 125 mm dia bore hole and installation of hand pump, fitting testing & commissioning of India Mark-II hand pumps provided by ODEX-115 method upto 65 mts BGL. | 1 | Mtr | |
| 158 | 127.02 | Extra beyond 65 mts to 100 mts BGL. | 1 | Mtr | |
| 159 | 127.03 | ERW MS Casing Pipe 125 mm dia minimum thickness 5.4 mm | 1 | Nos. | |
| 160 | 127.04 | Submersible pump set of suitable capacity and allied works . (Complete job) | 1 | Nos. | |
| 161 | 128 | Soil invesigation by way of Plate Load Test (As directed by the Engineer). | 1 | Nos. | |
| 162 | 129 | Structural Design & prepartion of drawings (As directed by Engineer). | 1 | Job | |
| 163 | 130 | Providing BALA (Building As Learning Aid) provisions as per drawing enlosed , including preparation of specific BALA drawings as per the directions of the Engineer. | 1 | Job | |
| 164 | 131 | Enviornment Management Plan | |||
| 165 | 131.01 | Providing 2 mt. high corrugated GI sheet (min. thickness 0.63 mm) barricading fixed with GI hooks and nuts on frame made of MS pipes having diameter not less than 40 mm. Spacing of vertical pipes shall not be less than 3 m (average) and minimum two horizontal pipes shall be provided. Rate shall be inclusive of cost of providing all materials and fixing arrangements, including excavation, transportion to site, fixing, backfilling, removal of the complete barricading after construction work is over and rehabilitation of the site etc., with all incidental charges, leads, lifts and all taxes and duties as applicable and as specified by Engineer-in-charge. Material of barricading shall be the property of contractor after completion the work. Barricading shall be maintained throughout the construction period. It should be installed in a manner so that one cannot crawl underneath it, should be sturdy enough to bear normal wear and tear at the construction site, should not topple off and hurt someone and should be strong enough to withstand the elements, including high wind conditions. Should be erected between existing building blocks and proposed structures and along the access roads. | 110 | Mtrs | |
| 166 | 131.02 | Provision, installation and maintenance of cautionary/warning signage, including diversion boards as per IRC specifications (SP:55, 2014) on the main road and along the access, including cost of boards and other materials required for fixing, with all incidental charges leads, lifts and all taxes as applicable from time to time and as specified by Engineer-in-charge. | 1 | Nos. | |
| 167 | 131.03 | Cost towards first aid and emergency response arrangements in the camp and worksite (including fire and electrical safety provisions) | 1 | LS | |
| 168 | 131.04 | Cost towards periodic health check-ups once in three months for all construction workers. | 1 | Nos. | |
| 169 | 132 | Provision for Workers | |||
| 170 | 132.01 | Providing of 2 number of mobile toilets 1 wet type and 1 dry type (bio-digester) \n | |||
| 171 | 132.02 | Wet type portable toilet (MS fabricated) 2 seats (1 for men and 1 for women with separate entrances), fitted with 2000 liters capacity overhead tank and 500 liters capacity bottom tank, fitted with Indian type of pot with other facilities such as tap, lighting and ventilation; and sludge tank of capacity 1000L, and stationed at a suitable place in or around 50 metres from work front. Includes cost of water, cost for emptying of bottom tank through mobile suction machine, attendent cost for looking after cleaning and operation of the toilets, all materials and labour charges, all incidental charges, leads, lifts and all taxes as applicable from time to time and as specified by Engineer-in-charge. | 1 | Nos. | |
| 172 | 132.03 | Dry type portable toilet (MS fabricated) (bio digestor) of approved design with 2 seats (one for men and one for women). Includes cost of water, cost for emptying of bottom tank through mobile suction machine, attendant cost for looking after cleaning and operation of the toilets, all materials and labour charges, all incidental charges, leads, lifts and all taxes as applicable from time to time and as specified by Engineer-in-charge.) | 1 | Nos. | |
| 173 | 133 | Providing of mobile drinking water counter/kiosk, fabricated from stainless steel with 300 liters capacity, with two taps and with bottom tank (300 litre holding capacity) to collect waste water and stationed at a suitable place within operational area, with one common attendant for both mobile toilet and drinking water kiosk. Cost includes charges for emptying bottom tank through suction machine, shifting cost of the kiosk from one operational area to another area, attendant cost for looking after cleaning and operation, all materials and all labour charges, all incidental charges, leads, lifts and all taxes as applicable from time to time and as specified by Engineer-in-charge | 1 | Nos. | |
| 174 | 134 | Other Environment, Health & Safety Measures | |||
| 175 | 134.01 | Information dissemination about type and schedule of civil works, utility shifting/damage/emergency repairs, complaint handling and all such issues that affect public/worker/near-by residents/building users close to the work zone. Dissemination modes to include display of banners/notices, distribution of handbills, organization of meetings and other appropriate means at least once in a month for the entire project duration. | 9 | Months | |
| 176 | 134.02 | Provision of Project Information Board in sheet steel and all supports, including fixing and maintenance during the entire project. Minimum board size should be 3 meters x 2 meters, with necessary information in English and local language written in black paint with white back ground. The board details and the required information will be furnished by the Engineer. The complete design, including logo and information to be displayed shall be approved by the Engineer. | 1 | Nos. | |
| 177 | 135 | Cost of environmental monitoring (air, water and noise) during entire construction period in line with parameters and frequency specified in the EMP. Ambient Air quality, Ambient Noise level and water quality monitoring. | |||
| 178 | 135.01 | Ambient Air Quality Monitoring for PM2.5 PM10,SO2, Nox and CO)-Noise Levels (dB) for Day and Night, Water Monitoring- Parameters specified in EMP. AAQ- Once before start of work and thereafter once in every quarter,AAN-Once before start of work and thereafter once in every month, Water monitoring - as specified EMP. | 1 | Job | |
| 179 | 135.02 | Disposal of extra earth/debris/similar unserviceable waste material by mechanical means, including loading, transporting, unloading to pre-approved dumping ground in line with EMP stipulations and as approved by Engineer-In-Charge. (SSR 2012 Code No 1.1.2) | 43 | Cum | |
| 180 | 136.03 | Demolishing of unserviceable line materials by mechanical means, including crushing at approved dumping ground in line with EMP stipulations and as per direction of Engineer-In-Charge | 43 | Cum | |
| 181 | 137 | Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete. | |||
| 182 | 137.01 | Sand by MT from Jammu for an avg lead of 224 Kms + by HL 1500 Mtrs. | 88 | Cum | |
| 183 | 137.02 | Stone agg. below 40mm size for an avg. lead of 44 Kms by MT + by HL 1500 Mtr | 138 | Cum | |
| 184 | 137.03 | Cement by MT from Local Market for an avg lead of 24 Kms + by HL 1500 Mtrs. | 55 | MT | |
| 185 | 137.04 | Steel by MT from Local Market for an avg lead of 24 Kms + by HL 1500 Mtrs. | 8 | MT | |
| 186 | 137.05 | Bricks for an average lead of 224 Kms by MT + by HL 1500 Mtr | 39134 | 1000/No | |
| 187 | 137.06 | Bricks for an average lead of 224 Kms by MT + by HL 1500 Mtr | 5833 | 1000/No |