Border Security Force-BSF has published Tender For Dry Dock Repair And Maintenance Of Fast Attack Craft ( Fac ) Agni Dry Dock Repair And Maintenance Of Fast Attack Craft ( Fac ) Agni. Submission Date for this Tender is 28-12-2019. Building Work Tenders in Lakkinala (Koteshwar) Gujarat. Bidders can get complete Tender details and download the document.
Name of Work: DRY DOCK REPAIR AND MAINTENANCE OF FAST ATTACK CRAFT AGNI | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | A. DECK SIDE/HULL SIDE :-\nAll Zinc anodes are required to replace with new one.\n | item1 | 1 | Job |
2 | 2 | Bow Thruster system required to repair | item2 | 1 | Job |
3 | 3 | Bow landing door, door spindle required servicing. \nAll hinges and doors rubber packing required replacing.\n\n | item3 | 1 | Job |
4 | 4 | Under water Hull required FRP repairing wherever damages noticed. Hull Maintenance, surface cleaning and Jel coating is also required | item4 | 1 | Job |
5 | 5 | AFT deck guard railing wire required to replace.\nThe locking system of the guard wires, also to be repaired. \n\n\n | item5 | 1 | Job |
6 | 6 | In side passenger cabin and pilot house side wall required repair and lamination. | item6 | 1 | Job |
7 | 7 | Anchoring system required to repair. \n | item7 | 1 | Job |
8 | 8 | Defective cleats required to replace with the bigger one for 16 mm parachute rope | item8 | 1 | Job |
9 | 9 | The side fender wherever damaged may be replace | item9 | 1 | Job |
10 | 10 | B.ENGINE SIDE Main Engine make MAN 800 BHP PORT/STBD side found completed Run-Hrs 2404 Hrs respectively. Both the main engine required servicing as per Run-Hrs covered. Other maintenance of Main engine and its system to be carried out. Defective sensors replacement. Defective silencer pipes and muffler’s replace and re-insulation \nInjector & fuel pump servicing required.\nEngine Srl No. 41032750983277 (Port)\nEngine Srl No. 41032751113277 (Stbd\n | item10 | 1 | Job |
11 | 11 | Chemical cleaning of heat exchanger oil cooler etc\n | item11 | 1 | Job |
12 | 12 | Turbocharger servicing. | item12 | 1 | Job |
13 | 13 | In sea water cooling line, valve and hose pipe of both main engine required checking and cleaning. | item13 | 1 | Job |
14 | 14 | C. STEERING SYSTEM :- \nSteering and HDM system/oil seals to be checked and if required to be repaired & serviced.\n | item14 | 1 | Job |
15 | 15 | D. GEAR BOX MODEL NO. ZF- 360\nGear box 02 Nos need servicing and defective spares to be replaced \n\n | item15 | 1 | Job |
16 | 16 | E. PROPULSION UNIT Marine Jet Propulsion System (MJP) needs servicing and defective spare parts like seal/bushes to be changed. Buckets and hub housing gap to be checked for maintaining necessary gaps. The impeller clearance to be checked and servicing\n | item16 | 1 | Job |
17 | 17 | F. DG SET \n8 KVA indigenous service facilitated marine DG Set complete new installation including cooling system in place of existing etc.\n\n | item17 | 1 | Job |
18 | 18 | G. SPECIAL EQUIPMENT :-\nDigital chart required up dated to the latest version and calibration.\n | item18 | 1 | Job |
19 | 19 | Remote operating Weapon (ROW) system required complete repairing.\n | item19 | 1 | Job |
20 | 20 | Search light required repair. | item20 | 1 | Job |
21 | 21 | Flood light required replace (LED)\n\n\n | item21 | 1 | Job |
22 | 22 | Both side wipers assy required servicing and blade to be replaced. | item22 | 1 | Job |
23 | 23 | Anemometer required replace | item23 | 1 | Job |
24 | 24 | H. LIFE SAVING EQUIPMENT :-\nLife raft to be renewed by refilling.\n | item24 | 1 | Job |
25 | 25 | All distress signals of the vessel should be servicing | item25 | 1 | Job |
26 | 26 | I. FIRE FIGHTING EQUIPMENT :-\nAll the fire extinguisher required to be replaced\n | item26 | 1 | Job |
27 | 27 | J. TANKs :- \nBlack water tank (Sewage tank) should be cleaned properly.\n | item27 | 1 | Job |
28 | 28 | Toilet system required servicing \n | item28 | 1 | Job |
29 | 29 | K. AC & VENTILATION :-\nMachinery room blower requred checking and repairing. Toilet and cabin blower may be repaired.\n | item29 | 1 | Job |
30 | 30 | Both AC plant required complete repairing. | item30 | 1 | Job |
31 | 31 | L. MISCELLANEOUS :-\nSeating chairs required repairing.\nBlower required repair \n02 Nos Bunk fans to be installed newly at the pilot cabin\n04 Nos Wall fans also to be installed at passenger cabin.\n | item31 | 1 | Job |
32 | 32 | Sea chest Non returning valves required replacement | item32 | 1 | Job |
33 | 33 | SS plates at bow to be replaced and FRP lamination | item33 | 1 | Job |
34 | 34 | Bushes of landing door to be replaced | item34 | 1 | Job |
35 | 35 | Both fuel gauges required replacing and visual fuel gauge system may be installed. Fuel tank and line required cleaning | item35 | 1 | Job |
36 | 36 | All the responding/non -responding sensors should be replaced. | item36 | 1 | Job |
37 | 37 | All bilge pumps and related pipe lines need to be checked and serviced. Bilge pump control panel (Auto/Manual switch) at wheel house need to be serviced. | item37 | 1 | Job |
38 | 38 | Wire rope key to be replaced | item38 | 1 | Job |
39 | 39 | Both side Main propeller shaft bearing required checking and defective parts be replaced\n | item39 | 1 | Job |
40 | 40 | M. PAINTING \nAll painting as per vessel requirement \n | item40 | 1 | Job |
41 | 41 | Under water hull painting with anti-fouling paints and primer | item41 | 1 | Job |
42 | 42 | N. DOCKING AND PILOTING CHARGES :-\nInspection charges including IRS fees\n | item42 | 1 | Job |
43 | 43 | Cost of Docking to carry out under water repair & painting etc & un-Docking. Cost of piloting & towing charges from Koteshwar ( Gujarat ) to builders yard and back including cost of fuel or dry dock at the Lakkinala by making cradles | item43 | 1 | Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail