Providing Of Services For Operation Of Sub Station In The Area Of Afmc Old Nda Wing Including Asi Area And Aipt Area Under Ge Central Pune , Providing Services For Operation Of The Following Sub Stations Combined With Complaint Cells In The Area Of Afmc , Old Nda Wing Including Asi Area And Aipt Area By Attending Various Ht/Lt Faults / Break Downs In The Sub Station Jurisdiction , Attending The Various Complaints As And When Required Round The Clock In Three Shifts , Separately By Three Fully Experienced Electricians ( One Electrician In Each Shift In Each Area ) In Each Shift Of 08 Hours Including Holidays And Sundays Etc Complete All As Specified And Directed By Engr-In-Charge . ( I ) Three Electricians In Three Shifts ( I . E . 01 Electrician In Afmc , 01 Electrician In Old Nda Wing Including Asi Area , 01 Electrician In Aipt Area In Each Shift ) As Under :- - 0600 Hrs To 1400 Hrs : First Shift- 1400Hrs To 2200 Hrs : Second Shift - 2200 Hrs To 0600 Hrs : Third Shift , Emergency Breakdown Services Are To Be Attended For The Following Substations Comes Under Afmc Area . , ( A ) Afmc Main Substation Combined With Complaint Cell Including Transformers 300 & 500 Kva Feeding To Afmc Hq Bldg And All Connected Areas Along With Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( B ) Transformer 200 Kva Installed At 450 Ors Pump House Locations Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( C ) Transformer 100 Kva At Laundry Area Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( D ) Transformer 50 Kva At Jcos Qtr Area Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( E ) Transformer 200 Kva At 53 Ors Area Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( F ) Transformer 160 Kva At Girls Hostel Area Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( G ) Transformer 500 Kva , 100Kva & 160Kva At Boys Hostel Pump House . Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( H ) Transformer 315 Kva At Central Cadet Mess Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( J ) Transformer 200 Kva At Kt Line Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( K ) Transformer 250 Kva At Btd Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( L ) Transformer 400 Kva & 315Kva At Dhanwantari Auditorium And Complex Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( M ) Transformer 250 Kva At Pump House For Offrs Mess Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( N ) Transformer 200 Kva At Golden Jubilee Block Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete All As Specified And Directed . , ( O ) Transformer 250 Kva & 200Kva At Mri & Irc Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( P ) Transformer But 400 Kva & 315 Kva At Diamond Jubilee Block Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( Q ) Transformer 200 Kva At New Library Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( R ) Transformer 160 Kva At New Btd Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( S ) Transformer 200Kva At Ct Scan Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( T ) Transformer 200Kva At Golden Jubilee For Offrs Mess Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( U ) Transformer 400Kva At Project Qtrs Area Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( V ) Transformer 200Kva At Pwd 12 Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , ( W ) Transformer 200Kva At Alc Dhobi Ghat Including Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete All As Specified And Directed . , Emergency Breakdown Services Are To Be Attended For The Following Sub Stations Comes Under Old Nda Wing And Asi Area . , ( A ) Old Nda Wing Area Substation Combined With Complaint Cell Including Transformers 400Kva Feeding To Old Nda Wing Area And 500 Kva Feeding To Asi Area Along With Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , Emergency Breakdown Services Are To Be Attended For The Following Sub Stations Comes Under Aipt Area . , ( A ) Aipt Area Substation Combined With Complaint Cell Including Transformers 400 Kva / 315 Kva Feeding To Aipt Area Along With Ht/ Lt Control Panels , God/Dos , Ht/Lt Cables , Over Head Lines , Under Ground Cables Etc Complete . , Notes For The Item No 1 :- , ( I ) Rates Quoted By The Tenderer For The Above Items Shall Deemed To Be Inclusive Of Cost Required For General Cleaning Of Sorrounding Area Of The Installation Complete . , ( Ii ) Protective Clothing As Per Is And Safety Instructions Are To Be Provided By The Contractor And Will Be Continuously In Use Of The Fgm / Electrician On Duty . No Extra Payment Shall Be Made To The Contractor For The Same . , ( Iii ) Log Sheet Shall Be Maintained By The Contractor Properly As Per The Format Approved By Engineer-In-Charge And The Same Shall Be Handed Over To Engineer-In-Charge On Completion Of Contract Period . , ( Iv ) Day To Day Maintenance Shall Be Carried Out By The Contractor . Materials Other Than Grease , Glands Shall Be Supplied By The Department . , ( V ) The Contractor Shall Employ Adequate Tradesmen For Weekly Off , Holiday And Leave Replacement And The Cost Of The Same Shall Deemed To Be Included In The Quoted Rate And No Additional Amount Will Be Paid In This Respect . , ( Vi ) All Stationary Items Such As Daily Log Sheet , Attendance Register , Complaint Register For Complaint Cell Shall Be Supplied By The Contractor Without Any Extra Cost .