Sales : +91-777 804 8217
| Name of Work: Construction of office Building of Different units (G.F & F.F) at UTKELA AIRSTRIP for the year 2019-20. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Earth work in excavation of foundation in hard soil including dressing and leveling the bed and depositing the soil within 50 m initial lead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 m in depth and as per direction of the Engineer-in-charge. | 197.24 | Cum | |
| 2 | 2 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge. | 163.46 | Cum | |
| 3 | 3 | Cement concrete of prop.(1:3:6) in foundation up to lowest bed level using crusher broken hard black granite metal of size 4cm down graded of approved quality from approved quarry as per approved design including hoisting,lowering,laying compacting concrete in layers not exceeding 6” thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty, & taxes of all materials, with labour, T&P required for the work etc., complete in all respects including dewatering if required as per direction of Engineer-in-Charge. | 28.7 | Cum | |
| 4 | 4 | Fly Ash brick masonary in Foundation and Plinth in cement mortar (1:6) in using Fly Ash Bricks of 25cm x 12cm x 8 cm having crushing strength not less than 75 Kg/Cm2 with dimentional tolerance +/- 8% including watering, curing and cost, conveyance, royality of all materials & cost of labour charges etc complete. | 50.18 | Cum | |
| 5 | 5 | R.C.C. work of M20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in position. | |||
| 6 | 5.01 | Column Base footings | 46.75 | Cum | |
| 7 | 5.02 | Plinth Beam | 5.84 | Cum | |
| 8 | 5.03 | Columns Ground Floor | 11.99 | Cum | |
| 9 | 5.04 | Columns First Floor | 13.12 | Cum | |
| 10 | 5.05 | Lintel Ground Floor | 3.73 | Cum | |
| 11 | 5.06 | Lintel First Floor | 3.73 | Cum | |
| 12 | 5.07 | Roof Beams Ground Floor | 7.76 | Cum | |
| 13 | 5.08 | Roof Beams First Floor | 8.45 | Cum | |
| 14 | 5.09 | Chajja Ground Floor | 26.38 | Sqm | |
| 15 | 5.1 | Chajja First Floor | 54.53 | Sqm | |
| 16 | 5.11 | Staircase Ground Floor | 5.1 | Cum | |
| 17 | 5.12 | Staircase First Floor | 5.1 | Cum | |
| 18 | 5.13 | Roof Slab Ground Floor | 28.29 | Cum | |
| 19 | 5.14 | Roof Slab First Floor | 30.11 | Cum | |
| 20 | 6 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. Ground Floor | 122.68 | Qntl | |
| 21 | 6.01 | First Floor | 72.24 | Qntl | |
| 22 | 7 | Fly Ash brick masonary in Super Structure in cement mortar (1:6) in using CB Bricks of 25cm x 11cm x 8 cm having crushing strength not less than 75 Kg/Cm2 with dimentional tolerance +/- 8% including watering, curing and cost, conveyance, royality of all materials & cost of labour charges etc complete. Ground Floor | 39.43 | Cum | |
| 23 | 7.01 | First Floor | 38.3 | Cum | |
| 24 | 8 | 20mm thick grading plaster in CM(1:4) with WP compound etc. comp. | 235.3 | Sqm | |
| 25 | 9 | Supplying of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S. Door/ window grill with all labour, iron fitting fitted and fixed in all respect including cost of iron etc. complete. | 1358.5 | Kg | |
| 26 | 10 | Providing 6 mm thick cement plaster with cement mortar of mix (1:3) with screened and washed sharp sand for mortar and finished smooth to the RCC works after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground Floor | 260.86 | Sqm | |
| 27 | 10.01 | First Floor | 300.16 | Sqm | |
| 28 | 11 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground Floor | 338.48 | Sqm | |
| 29 | 11.01 | First Floor | 263.23 | Sqm | |
| 30 | 12 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground Floor | 357.34 | Sqm | |
| 31 | 12.01 | First Floor | 398.94 | Sqm | |
| 32 | 13 | Providing & fixing Vitrified tiles in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete Ground Floor | 190.63 | Sqm | |
| 33 | 13.01 | First Floor | 178.37 | Sqm | |
| 34 | 14 | Fixing ofIndustrial Vitrified tiles of premium Grade in floors treads or steps and landing on 25 mm thick bed of cement mortar 1:4 jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbibg and polishing etc complete. Ground Floor\n | 18.59 | Sqm | |
| 35 | 14.01 | First Floor | 18.59 | Sqm | |
| 36 | 15 | Finishing wall surface of walls with cement based wall Putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of all materials, labour T&P etc required for the work all complete Ground Floor | 986.85 | Sqm | |
| 37 | 15.01 | First Floor | 995.52 | Sqm | |
| 38 | 16 | Painting two coats with plastic emulsion paint over a coat of water bond cement primer to make an even finished surface in all floors and heighyts to wall surface of approved make and shade including sand papering, applying putty whereever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials and labour with T & P etc. complete in all respect as per the direction of the Engineer-in-Charge. Ground Floor | 678.47 | Sqm | |
| 39 | 16.01 | First Floor | 760.34 | Sqm | |
| 40 | 17 | White cement washing one coats with good White Cement including cost,conveyance,taxes, all labour etc.complete. Ground Floor | 338.48 | Sqm | |
| 41 | 17.01 | First Floor | 263.23 | Sqm | |
| 42 | 18 | Anti fungal weather paint of any approved shade on new work of two coats with one coat of Primer in all floors, all heights with staging wherever necessary with cost, conveyance, taxes of all materials, cost of all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground Floor | 338.48 | Sqm | |
| 43 | 18.01 | First Floor | 263.23 | Sqm | |
| 44 | 19 | Painting two coats with any approved enamel paint of approved colour, shade over one coat primer on new steel work and wood work including sand papering, polishing the surface, cost, conveyance, taxes of all materials and labour with T & P etc. complete as per specification and direction of Engineer-in-charge. Ground Floor | 11.01 | Sqm | |
| 45 | 19.01 | First Floor | 15.4 | Sqm | |
| 46 | 20 | Dressed seasoned sal wood work framed and fixed (wrought and put up) in frames of doors, windows, ventilabours etc.comp. | 0.42 | Cum | |
| 47 | 21 | Providing & fixing Factory made 30mm/32mm thick flush door shutter (nonsal hardwood frame fixed with 4mm BWR Ply on both side of frame) with all labour, iron fittings & wooden hinged cleats etc. fitted & fixed complete in all respect. | 18.2 | Sqm | |
| 48 | 22 | Supplying & fixing fully glazed aluminium three track sliding window including all hardware fittings etc. comp. excluding cost of glass | 271.86 | Kg | |
| 49 | 23 | Provding and fixing 5mm thick plain glass in aluminium window and ventilator frame etc. complete | 47.66 | Sqm | |
| 50 | 24 | Providing & fixing Stainless Steel railing with stainless steel balusters etc. comp. | 907.9 | Kg | |
| 51 | 25 | E.I Works:- Recessed modular wiring to Light/ Fan/ Call bell and Exhaust fan point with 1.5 mm2 F.R. PVC insulated single core multi strand copper conductor of ISI marked with 50mm dia Non metallic with 20mm dia non metalic PVC flexible conduit with 5/6 250volt modular type switch,ceilling rose mounted on MS box having front bakelite cover of suitable size M.S box with 1.5mm2 FR pvc insuleted S/C multistand copper conductor as earth wire Including all accessories and connection.as per direction of ingineer-in-charge. (Make of wire Finolex/Anchore/ Havels/HPL/L&T/ V.Guard. | |||
| 52 | 26 | Ground Floor | |||
| 53 | 27 | a)Group-A | 21 | Nos | |
| 54 | 28 | b) Group-B | 18 | Nos | |
| 55 | 29 | c) Group-C | 14 | Nos | |
| 56 | 30 | First Floor | |||
| 57 | 31 | a)Group-A | 23 | Nos | |
| 58 | 32 | b) Group-B | 17 | Nos | |
| 59 | 33 | c) Group-C | 13 | Nos | |
| 60 | 34 | Recesed wiring to 5/6A. modular type socket outlet with 2x1.5mm2 F.R. PVC insulated S.C multistrand Copper conductor of ISI marked in 20mm dia non-metalic PVC flexible conduit pipe with modular type switch, phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1x1.5mm2 FR PVC insulated single core multistrand copper conductor for loop earthing etc.as required. (make of wire Finolex/Anchre/havels/HPL/L&T/V.guard) | |||
| 61 | 35 | Ground Floor | |||
| 62 | 36 | a) Group-A | 8 | Nos | |
| 63 | 37 | b) on existing board | 9 | Nos | |
| 64 | 38 | First Floor | |||
| 65 | 39 | a) Group-A | 8 | Nos | |
| 66 | 40 | b) on existing board | 9 | Nos | |
| 67 | 41 | Ground Floor | |||
| 68 | 42 | Recessed modular wiring to power plug point consisting of 16A modular shuttered socket and 16A indicator type switch with 2x4mm2 PVC Insulatted S.C F.R multistand Cu.wire ISI marked in 20mm non-metalic PVC flexible conduit along with 1x1.5mm2 F.R PVC insulated S.C C.U. wire for loop earthing as required of Havels make. | 17 | Nos | |
| 69 | 43 | First Floor | |||
| 70 | 44 | Recessed modular wiring to power plug point consisting of 16A modular shuttered socket and 16A indicator type switch with 2x4mm2 PVC Insulatted S.C F.R multistand Cu.wire ISI marked in 20mm non-metalic PVC flexible conduit along with 1x1.5mm2 F.R PVC insulated S.C C.U. wire for loop earthing as required of Havels make. | 9 | Nos | |
| 71 | 45 | Wiring to Circuit/ Sub-main along with earth wire with following size of FR PVC S.C.Cu. Wire (Make of wire Finolex/ Anchor/ Havels/HPL/L&T/ V.Guard. | |||
| 72 | 46 | Ground floor | |||
| 73 | 47 | 1x1.5mm2 Sub-Main Wiring for Invertor onnectiom. | 93 | Mtrs | |
| 74 | 48 | a) (1.8.1) 2X1.5mm2 + 1x1.5mm2 | 57 | Mtrs | |
| 75 | 49 | b) (1.8.2) 2X2.5mm2 + 1x1.5mm2 | 287 | Mtrs | |
| 76 | 50 | c) (1.8.3) 2X4mm2 + 1x1.5mm2 | 203 | Mtrs | |
| 77 | 51 | d)(1.8.4) 2x6mm2 +1x2.5mm2 | 104 | Mtrs | |
| 78 | 52 | First Floor | |||
| 79 | 53 | 1x1.5mm2 Sub-Main Wiring for Invertor onnectiom. | 92 | Mtrs | |
| 80 | 54 | a) (1.8.1) 2X1.5mm2 + 1x1.5mm2 | 50 | Mtrs | |
| 81 | 55 | b) (1.8.2) 2X2.5mm2 + 1x1.5mm2 | 223 | Mtrs | |
| 82 | 56 | c) (1.8.3) 2X4mm2 + 1x1.5mm2 | 136 | Mtrs | |
| 83 | 57 | d)(1.8.4) 2x6mm2 +1x2.5mm2 | 102 | Mtrs | |
| 84 | 58 | Ground Floor | |||
| 85 | 59 | S/F of computer Board consisting of 3 Nos Modular plug and switch all accessories including recessed wiring,Cutting of wall & connection as per requirement. | 16 | Nos | |
| 86 | 60 | First Floor | |||
| 87 | 61 | S/F of computer Board consisting of 3 Nos Modular plug and switch all accessories including recessed wiring,Cutting of wall & connection as per requirement. | 8 | Nos | |
| 88 | 62 | Ground Floor | |||
| 89 | 63 | S/F of step type Modular electronic fan regulator of Anchor/Deluxe/Cona make | 8 | Nos | |
| 90 | 64 | First Floor | |||
| 91 | 65 | S/F of step type Modular electronic fan regulator of Anchor/Deluxe/Cona make | 8 | Nos | |
| 92 | 66 | Ground Floor | |||
| 93 | 67 | S/F. of 8Way double door D.Box with 25A DP of C series + 6x6A B series SP MCB of Havels/ L&T/HPL make. | 2 | Nos | |
| 94 | 68 | First Floor | |||
| 95 | 69 | S/F. of 8Way double door D.Box with 25A DP of C series + 6x6A B series SP MCB of Havels/ L&T/HPL make. | 2 | Nos | |
| 96 | 70 | Ground Floor | |||
| 97 | 71 | S/F of (4+12) way double door TPN distribution Box for single phase out going of Havels make Cutlog no-DHDQTHCSRWOY incoming- 63Amp TPN MCB of havells make, outgoing-4x 32 Amp and 2x25amp C series DP MCB of Havels make. | 2 | Nos | |
| 98 | 72 | First Floor | |||
| 99 | 73 | S/F of (4+12) way double door TPN distribution Box for single phase out going of Havels make Cutlog no-DHDQTHCSRWOY incoming- 63Amp TPN MCB of havells make, outgoing-4x 32 Amp and 2x25amp C series DP MCB of Havels make. | 1 | Nos | |
| 100 | 74 | Ground Floor | |||
| 101 | 75 | S/F of Standard Earthing with G.I. earth pipe of 3mtr.Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. | 3 | Nos | |
| 102 | 76 | First Floor | |||
| 103 | 77 | S/F of Standard Earthing with G.I. earth pipe of 3mtr.Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. | 3 | Nos | |
| 104 | 78 | Ground Floor | |||
| 105 | 79 | S/F of Call bell/ Buzzer and Bell push and flexible cord . | 1 | No | |
| 106 | 80 | First Floor | |||
| 107 | 81 | S/F of Call bell/ Buzzer and Bell push and flexible cord . | 1 | No | |
| 108 | 82 | Ground Floor | |||
| 109 | 83 | S/F of BEE 5 star rated 48\" Ac ceilling Fan of model usha ergo 5 star (beige brown/royal green colour)/ bajaj regal star(ivory/white)/crompton greaves aura plus (white/titanium) w/o Regulator of ISI marked. | 8 | Nos | |
| 110 | 84 | First Floor | |||
| 111 | 85 | S/F of BEE 5 star rated 48\" Ac ceilling Fan of model usha ergo 5 star (beige brown/royal green colour)/ bajaj regal star(ivory/white)/crompton greaves aura plus (white/titanium) w/o Regulator of ISI marked. | 8 | Nos | |
| 112 | 86 | Ground floor | |||
| 113 | 87 | S/F of 15watt Surface mounted LED down light complete of Havells/Bajaj/HPL make. | 5 | Nos | |
| 114 | 88 | First Floor | |||
| 115 | 89 | S/F of 15watt Surface mounted LED down light complete of Havells/Bajaj/HPL make. | 5 | Nos | |
| 116 | 90 | Ground floor | |||
| 117 | 91 | S/F of 18wt LED T.L fitting of Phillips/ Bajaj/Havels make | 8 | Nos | |
| 118 | 92 | First Floor | |||
| 119 | 93 | S/F of 18wt LED T.L fitting of Phillips/ Bajaj/Havels make | 8 | Nos | |
| 120 | 94 | Ground floor | |||
| 121 | 95 | S/F of 12wt LED ceilling down light complete with lamp of Havels/HPL/Bajaj make. | 16 | Nos | |
| 122 | 96 | First Floor | |||
| 123 | 97 | S/F of 12wt LED ceilling down light complete with lamp of Havels/HPL/Bajaj make. | 16 | Nos | |
| 124 | 98 | Ground floor | |||
| 125 | 99 | S/F of Ultra modern surface mounted Decorative oval Bulk head edge LED Luminaire complete with 10watt LED lamp. (Make Havells/Endura Rugby model) | 2 | Nos | |
| 126 | 100 | Ground floor | |||
| 127 | 101 | S/F of B.K Angle Holder. | 9 | Nos | |
| 128 | 102 | First Floor | |||
| 129 | 103 | S/F of B.K Angle Holder. | 9 | Nos | |
| 130 | 104 | Ground floor. | |||
| 131 | 105 | S/F of 10wt LED Bulb of Havels/HPL/Bajaj make. | 9 | Nos | |
| 132 | 106 | First Floor | |||
| 133 | 107 | S/F of 10wt LED Bulb of Havels/HPL/Bajaj make. | 9 | Nos | |
| 134 | 108 | Ground floor. | |||
| 135 | 109 | S/F of 300mm Exhaust Fan of model Usha turbo jet /Bajaj freshee with louvers i.e safe guard . | 4 | Nos | |
| 136 | 110 | First Floor | |||
| 137 | 111 | S/F of 300mm Exhaust Fan of model Usha turbo jet /Bajaj freshee with louvers i.e safe guard . | 4 | Nos | |
| 138 | 112 | Ground floor. | |||
| 139 | 113 | S/F of 90wt LED Street light of Havels/HPL/Bajaj make. | 2 | Nos | |
| 140 | 114 | Ground floor. | |||
| 141 | 115 | Supply and Fixing of GI bend pipe for street light including all accessories i.e clamp or jam lock etc | 2 | Nos | |
| 142 | 116 | First Floor | |||
| 143 | 117 | Supply and laying of 25mmx5 mm GI Earth Strip of ISI marked including soldering etc. | 27 | Mtrs | |
| 144 | 118 | Ground floor. | |||
| 145 | 119 | S/F of 25Amp AC Starter of Anchor/Havells make. | 4 | Nos | |
| 146 | 120 | First Floor | |||
| 147 | 121 | S/F of 25Amp AC Starter of Anchor/Havells make. | 4 | Nos | |
| 148 | 122 | First Floor | |||
| 149 | 123 | Provision of lightning arrester with 85mm dia 3mm thick copper base pate and copper tape 20x3mmthick including all accessories. | 2 | Nos | |
| 150 | 124 | First Floor | |||
| 151 | 125 | S/F of Special Earthing complete with provision of 600x600x3.15mm thick copper plate along with 25x5mm copper strip in 40mm dia GI pipe including soldering of strip if necessary and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.(For lightning Arrester) | 1 | Nos | |
| 152 | 126 | Ground floor. | |||
| 153 | 127 | S/F of New Minimax\" 4kg ABC Dry power (S/P) Type Fire Extinguisher pressurized with dry Nitrozen gas at 15 bar.as per IS 15683 with fire rating 2A,21B,at 35 bar,operating temperature-30 C to + 55 C,supplied with standard accessories. | 2 | Nos | |
| 154 | 128 | First Floor | |||
| 155 | 129 | S/F of New Minimax\" 4kg ABC Dry power (S/P) Type Fire Extinguisher pressurized with dry Nitrozen gas at 15 bar.as per IS 15683 with fire rating 2A,21B,at 35 bar,operating temperature-30 C to + 55 C,supplied with standard accessories. | 2 | Nos | |
| 156 | 130 | Ground floor. | |||
| 157 | 131 | S/F of 4 Nos of Fire Bucket with Fire Bucket Stand made up of Galvanized mild steel conforming to IS-2546-1974. | 1 | Nos | |
| 158 | 132 | First Floor | |||
| 159 | 133 | S/F of 4 Nos of Fire Bucket with Fire Bucket Stand made up of Galvanized mild steel conforming to IS-2546-1974. | 1 | Nos | |
| 160 | 134 | Ground floor. | |||
| 161 | 135 | S/F of Copper 3 Star Rated (With EER 3.5) 1.5 Ton Split type AC.Machine make of Carrier(Octra-X)/Voltas (185ZYJ) | 4 | Nos | |
| 162 | 136 | First Floor | |||
| 163 | 137 | S/F of Copper 3 Star Rated (With EER 3.5) 1.5 Ton Split type AC.Machine make of Carrier(Octra-X)/Voltas (185ZYJ) | 4 | Nos | |
| 164 | 138 | Ground floor. | |||
| 165 | 139 | S/F of 4KVA Voltage stabiliser having digital display ,intial time delay system i.e certified with ISO 9001:2008 with working range of (90-300)V of make V.guard/Autotake | 4 | Nos | |
| 166 | 140 | First Floor | |||
| 167 | 141 | S/F of 4KVA Voltage stabiliser having digital display ,intial time delay system i.e certified with ISO 9001:2008 with working range of (90-300)V of make V.guard/Autotake | 4 | Nos | |
| 168 | 142 | Ground floor. | |||
| 169 | 143 | Installation charges of 1.5 ton AC.machine. | 4 | Nos | |
| 170 | 144 | First Floor | |||
| 171 | 145 | Installation charges of 1.5 ton AC.machine. | 4 | Nos | |
| 172 | 146 | Ground floor. | |||
| 173 | 147 | S/F of Extra long copper pipe for indoor unit to out door unit. | 8 | Mtrs | |
| 174 | 148 | First Floor | |||
| 175 | 149 | S/F of Extra long copper pipe for indoor unit to out door unit. | 8 | Mtrs | |
| 176 | 150 | Ground floor. | |||
| 177 | 151 | Supply & Laying of Class-C Rubber Mat of ISI marked conforming to IS- 15652/2006 having Di-electric strength of 65KV and size-(1mtr.x2mtr.x8mm). | 1 | Nos | |
| 178 | 152 | Ground floor. | |||
| 179 | 153 | Fabrication of 100A panel board of size 770mmx930mmx310mm with powder coat made out of 18 SWG CR sheet with provn of Incoming 100 Amp 35KA 4-pole MCCB of Havels make-1no,200Amp copper Bus bar 25mmx12mm copper flat-1No,Fixed magnetic setting with Ics=100% 63Amp 16KA 4-pole MCCB of L&T make-2 Nos,100A onload change over of Havels make-1no ,32Amp DP MCB of havells/L&T/ make-6 Nos complete with pre-wired digital Volt meter,Ammeter,selector switch,C.P.Coil and Indicator lamp RYB includingTransporation and fixing charges. | 1 | Nos | |
| 180 | 154 | Forst Floor | |||
| 181 | 155 | Fabrication of 100A panel board of size 770mmx930mmx310mm with powder coat made out of 18 SWG CR sheet with provn of Incoming 100 Amp 35KA 4-pole MCCB of Havels make-1no,200Amp copper Bus bar 25mmx12mm copper flat-1No32Amp DP MCB of havells/L&T/ make-10 Nos complete with pre-wired digital Volt meter,Ammeter,selector switch,C.P.Coil and Indicator lamp RYB includingTransporation and fixing charges. | 1 | Nos | |
| 182 | 156 | Ground floor. | |||
| 183 | 157 | S/F 3 1/2 core x 25 mm2 PVC Al Armoured Cable Of ISI Marked (Polycab/Nicco/Havels) | 63 | Mtrs | |
| 184 | 158 | Cable Treanching in all type os Soil including excavation of earth,laying of cable upto25mm2 & filling of loose soil upto ground level . | 52 | Mtrs | |
| 185 | 159 | S/F 4 x 16 mm2 PVC Al Armoured Cable Of ISI Marked (Polycab/Nicco/Havels) | 63 | Mtrs | |
| 186 | 160 | Laying of cable on wall surface by clamping. | 58 | Mtrs | |
| 187 | 161 | G.P.H Works:- Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. | |||
| 188 | 162 | 15mm dia PVC Pipe | |||
| 189 | 163 | Ground Floor | 20 | Mtrs. | |
| 190 | 164 | First Floor | 15 | Mtrs. | |
| 191 | 165 | 25mm dia PVC Pipe | |||
| 192 | 166 | Ground Floor | 60 | Mtrs. | |
| 193 | 167 | First Floor | 40 | Mtrs. | |
| 194 | 168 | 32mm dia PVC Pipe | 55 | Mtrs. | |
| 195 | 169 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | |||
| 196 | 170 | 15mm dia CP angle stop cock (Jaquar)CON-CHR-059KN | 12 | Each | |
| 197 | 171 | 15mm dia CP two way bib cock (Jaquar)CON-041KN | 4 | Each | |
| 198 | 172 | 15mm dia CP short body bib cock (Jaquar)CON-CHR-047KN | 4 | Each | |
| 199 | 173 | 15mm dia CP long body bib cock (Jaquar Make)CON-107KN | 4 | Each | |
| 200 | 174 | 25mm dia brass full way valve (Shakti make) | 2 | Each | |
| 201 | 175 | 32mm dia brass full way valve (Shakti make) | 3 | Each | |
| 202 | 176 | 25mm dia CP Health Faucet (Jaquar Make)ALD - CHR - 565 | 4 | Each | |
| 203 | 177 | Flush cock with wall flange (Jaquar make) (APR - ESS - 101081) | 2 | Each | |
| 204 | 178 | 15mm CP Extension piece | 24 | Each | |
| 205 | 179 | 125mm CP grating | 14 | Each | |
| 206 | 180 | 15mm size C.P. flange | 24 | Each | |
| 207 | 181 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge | |||
| 208 | 182 | 2000 liters capacity PVC water storage tank roof of 1st floor | 2 | Each | |
| 209 | 183 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. | |||
| 210 | 184 | Ground Floor | 6 | Each | |
| 211 | 185 | First Floor | 2 | Each | |
| 212 | 186 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge | |||
| 213 | 187 | Ground Floor | 4 | Each | |
| 214 | 188 | First Floor | 4 | Each | |
| 215 | 189 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. | |||
| 216 | 190 | Ground Floor | 45 | Mtr | |
| 217 | 191 | First Floor | 30 | Mtr | |
| 218 | 192 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | |||
| 219 | 193 | 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) | 65 | Mtr. | |
| 220 | 194 | 75mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) | 50 | Mtr. | |
| 221 | 195 | 110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make) | 14 | Each | |
| 222 | 196 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) | 4 | Each | |
| 223 | 197 | 75mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) | 6 | Each | |
| 224 | 198 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) | 8 | Each | |
| 225 | 199 | 75mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) | 12 | Each | |
| 226 | 200 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) | 4 | Each | |
| 227 | 201 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) | 4 | Each | |
| 228 | 202 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) | 8 | Each | |
| 229 | 203 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) | 14 | Each | |
| 230 | 204 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) | 22 | Each | |
| 231 | 205 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | |||
| 232 | 206 | 580mm size Orissa pan (Hindware/Parryware/Neycer make) | 2 | Each | |
| 233 | 207 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge | |||
| 234 | 208 | 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) | 6 | Each | |
| 235 | 209 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge | 2 | Each | |
| 236 | 210 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal | 2 | Each | |
| 237 | 211 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge | |||
| 238 | 212 | European water closet with 'p' trap plain(Hindware/Parryware/Neycer make) | 4 | Each | |
| 239 | 213 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge | |||
| 240 | 214 | 550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with pedestal\n | 2 | Each | |
| 241 | 215 | Counter Top Basin (560x455) (Perryware/Hindware/nycer Make) white with 15mm C.P. Pillar cock (jaquar/essco) | 2 | Each | |
| 242 | 216 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge | |||
| 243 | 217 | 25mmx600mm long CP towel rail CAN - ACR - 1111BNM | 6 | Each | |
| 244 | 218 | Towel ring CAN - BCH - 1121 | 4 | Each | |
| 245 | 219 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. | |||
| 246 | 220 | 600mmx125mm plate glass shelf (Jaquar) CAN - BCH - 1171N | 4 | Each | |
| 247 | 221 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. | |||
| 248 | 222 | 600mmx450mm size B.E mirror (swivelled type) | 4 | Each | |
| 249 | 223 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge | |||
| 250 | 224 | CP soap holder (Jaquar)CAN - MCH - 1131N | 6 | Each | |
| 251 | 225 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge | 16 | Each | |
| 252 | 226 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge | 8 | Each | |
| 253 | 227 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge | |||
| 254 | 228 | Inside size 76cmx76cmx46cm with 18” dia RCC MH cover | 4 | Each | |
| 255 | 229 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge | 3 | Each | |
| 256 | 230 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge | 1.76 | Cum | |
| 257 | 231 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge | |||
| 258 | 232 | Ground Floor | 1.76 | Cum | |
| 259 | 233 | First Floor | 1.67 | Cum | |
| 260 | 234 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge ) | |||
| 261 | 235 | Ceramic tile 30cmx30cm | |||
| 262 | 236 | Ground Floor | 18.5 | Sqm | |
| 263 | 237 | First Floor | 11.57 | Sqm | |
| 264 | 238 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | |||
| 265 | 239 | Ground Floor | 81.67 | Sqm | |
| 266 | 240 | First Floor | 50.57 | Sqm | |
| 267 | 241 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge ) | |||
| 268 | 242 | Glazed tile 30cmx20cm | |||
| 269 | 243 | Ground Floor | 81.67 | Sqm | |
| 270 | 244 | First Floor | 50.57 | Sqm | |
| 271 | 245 | Granite tiles | 2.7 | Sqm | |
| 272 | 246 | Providing fitting, fixing of Aluminium door with anodized AL. door section of 9202 as vertical member,9201 as top and 9200 as middle bottom member with frame section No. 9221 and tapered clip no. 4660 and the frame to be completed by means of jointing angle No. 1855 Including all Cost of Labour. T&P hire charges of drilling machine. labour charges etc. complete. Ref : OBI10 | 9.71 | Sqm | |
| 273 | 247 | Supplying all materials, labour, T&P and providing brick work in super structure with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge | 1 | Cum. | |
| 274 | 248 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 120 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 120 liter's along with 3 noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge | |||
| 275 | 249 | Aqua guard pure Chill 120 PSS UV | 2 | Each | |
| 276 | 250 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge | |||
| 277 | 251 | 100mm dia P.V.C. pipe | 30 | Mtr. | |
| 278 | 252 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. | |||
| 279 | 253 | MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover ) | 1 | Each | |
| 280 | 254 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. | 2 | Each | |
| 281 | 255 | 1 no 50 Users septic tank | |||
| 282 | 256 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. | 29.2 | Cum. | |
| 283 | 257 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. | 19.47 | Cum. | |
| 284 | 258 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. | 33 | Cum. | |
| 285 | 259 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge | 4.38 | Cum. | |
| 286 | 260 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. | 1.53 | Cum. | |
| 287 | 261 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. | 1.55 | Qntl. | |
| 288 | 262 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge | |||
| 289 | 263 | RCC floor, roof slab chhaja up to 4.430 m height | 7.7 | Sqm. | |
| 290 | 264 | Supplying all materials.labour.T&P and providing brick work in foundation and plinth with KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:3 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. | 15.84 | Cum. | |
| 291 | 265 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | 35 | Sqm. | |
| 292 | 266 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:6) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | 55 | Sqm. | |
| 293 | 267 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge | 35 | Sqm. | |
| 294 | 268 | Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. | 10 | Each | |
| 295 | 269 | Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. | 2 | Each | |
| 296 | 270 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. | 5.84 | Cum. | |
| 297 | 271 | Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories | |||
| 298 | 272 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only | |||
| 299 | 273 | Drilling of 200mm dia bore | |||
| 300 | 274 | 00 mtr to 30mtr | 30 | mtr | |
| 301 | 275 | 30 mtr to 45mtr | 5 | mtr | |
| 302 | 276 | Drilling of 150mm dia bore | |||
| 303 | 277 | 45 mtr to 215.00mtr | 100 | mtr | |
| 304 | 278 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. | |||
| 305 | 279 | Lowering of 200mm dia P.V.C casing pipes | |||
| 306 | 280 | 00 mtr to 30 mtrs | 30 | mtr | |
| 307 | 281 | 30 mtr to 60mtr | 5 | mtr | |
| 308 | 282 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. | |||
| 309 | 283 | 200mm dia PVC (sch-80) pipe | 35.5 | mtr | |
| 310 | 284 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) | 1 | Each | |
| 311 | 285 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge | |||
| 312 | 286 | By DTH Rig | 1 | Each | |
| 313 | 287 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: | |||
| 314 | 288 | Rocky terrain with boulder formation for 300m depth | 2 | Each site | |
| 315 | 289 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) | |||
| 316 | 290 | 1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) | 1 | Each | |
| 317 | 291 | DOL Control panel | 1 | Each | |
| 318 | 292 | 40mm dia steel short piece | 1 | Each | |
| 319 | 293 | Well cap | 1 | Each | |
| 320 | 294 | 50mm size CI bracket | 1 | Pair | |
| 321 | 295 | 2.50sqmm flat cable | 90 | Mtr | |
| 322 | 296 | 20mm dia rigid UPVC pipes | 30 | Mtr | |
| 323 | 297 | Steel rope with cover | 55 | Mtr | |
| 324 | 298 | Labour charges for lowering including transportation | 1 | Each | |
| 325 | 299 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge | |||
| 326 | 300 | 32mm HDPE pipes (Finolex/Supreme make) | 55 | mtr |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy