| 1 | 1 | Supply of various types of Chemical for testing namely \nCRM of sulphae (merk) | 1 | 1 | Each |
|---|
| 2 | 2 | CRM of iron | 2 | 1 | Each |
|---|
| 3 | 3 | CRM of nitrate | 3 | 1 | Each |
|---|
| 4 | 4 | Supply of CRM of sodium fluoride | 4 | 1 | Each |
|---|
| 5 | 5 | Supply of CRM of potassium dichromate | 5 | 1 | Each |
|---|
| 6 | 6 | Supply of CRM of potassium chloride | 6 | 1 | Each |
|---|
| 7 | 7 | Supply of CRM of calcium carbonate | 7 | 1 | Each |
|---|
| 8 | 8 | Supply of CRM of sodium chloride | 8 | 1 | Each |
|---|
| 9 | 9 | Supply of CRM of PH buffer-7 | 9 | 1 | Each |
|---|
| 10 | 10 | Supply of CRM of PH buffer - 4 | 10 | 1 | Each |
|---|
| 11 | 11 | Supply of CRM of PH buffer - 10 | 11 | 1 | Each |
|---|
| 12 | 12 | Supply of Silver Sulphate | 12 | 1 | Each |
|---|
| 13 | 13 | Silver nitrate | 13 | 1 | Each |
|---|
| 14 | 14 | Spands for fluoride (hach) | 14 | 2 | Each |
|---|
| 15 | 15 | Ferrover of iron (hach) | 15 | 2 | Each |
|---|
| 16 | 16 | Nitraver for nitrate (hach) | 16 | 2 | Each |
|---|
| 17 | 17 | Sulfaver for sulphate (hach) | 17 | 2 | Each |
|---|
| 18 | 18 | Supply of Digital Electronic Balance Make: Ohaus/Shimazo/ Mettler Toledo Capacity 220gm., Readability 0.1mg, Pan Size(mm) : 85-91 mm dia High Contrast, Large Backlite LCD display for easy viewing with A.E.P. (Advanced Eye Protection) Standard RS 232 C interface. Automatic Internal calibration Various weighing units like gm, mg, ct, oz, dwt, mom, GN User selectable stability and filter level. Calibration: Calibration certificate from any NABL certified Laboratory required with validity of at least 1 Year. Calibration Certifiate From NABL Certified Lab Required | 18 | 1 | Each |
|---|
| 19 | 19 | Bench Top-pH Meter-Make Eutech/Hach/Others specifications\n* pH Range - 2.00 to 16.00 pH\n* Resolution 0.01 pH\n* Accuracy +- 0.01 pH\n* Cal. Points up to 5\nBuffer Sets USA (1.68, 4.01, 7.00, 10.01, 12.45)\nNIST (1.68, 4.01, 6.86, 9.18 , 12.45)\nORP\n* Range ? 2000 m V\n* Rel. mV Range ?????? mV\n* Resolution 0.1 m V (? 199.9 mV)/ 1 m V (beyond)\n* Accuracy ? 0.2 m V (? 199.9 mV) / ? 2mV (beyond) Temperature\n* Range (Meter) 0.0 to 100.00 C/ 32.0 to 21.20 0F\n* Resolution 0.10C/0.10F\n* Accuracy ? 0.30 C/? 0.50F 0 to 700C)\n* Compensation ATC/ MTC (0 to 1000C ) (pH only)\n* Calibration offset in 0.10 increments\n* offset range : ? 5.00 C/ ? 9.00 F\n* Power Requirements 9 V DC adapter, 1.3 A (100/240 VAC, SMPS)\n | 19 | 1 | Each |
|---|
| 20 | 20 | Supply of Benchtop TDS/Conductivity meter (Specification)\nMake:- Eutech, Singapore, Patsio, Conductivity , Mettler Toledo \nRange 6 auto-selected from 0 to 19.99S* \nResolution 0.01µS -0.01S \nAccuracy ±0.5% ±2 digits \nAutomatic std. recognition 10µS, 84µS, 1413µS, 12.88mS \nCell constant 0.010 to 19.999 \nTDS 6 auto selected ranges \nRanges 0-1999g/l*\nResolution 0.01mg/l -1g/l \nAccuracy ±0.5% ±2 digits \nEC ratio 0.50 to 0.80 \nResistivity \nRange 0-20Mohm Resolution 0.01Mohm \nAccuracy ±0.5% ±2 digits Salinity Range 0-99.9g/l \nResolution 0.1g/l Accuracy 0-35 ±1g/l, 35-99.9 ±3g/l \nTemperature \nRange -10 to 105°C \nResolution 0.1°C \nAccuracy ±0.5°C \nATC and manual 0 to 100°C \nTemperature coefficient 0.00% to 4.00%/ºC \nReference temperature 18, 20 or 25°C \nGLP Calibration reminder interval, alarm outputs and security code protected data \nOutputs Analogue, RS232 and IrDA interface \nConnector 7-pin DIN \nCalibration Certifiate From NABL Certified Lab Required\n | 20 | 1 | Each |
|---|
| 21 | 21 | Benchtop Ion meter (ISE) along with\nFluoride, Nitrate Electorde Make\nOrion/Hach/Others\nSpecifications\nPh. Range-2.000 to 20.000\nResolution 0.1,0.01, 0.001\nRelative Accuracy? 0.002 \nCalibration Points Up to 5\nCalibration Editing Yes m V/RmV\nRange ?2000.0 mV Resolution 0.1\nRelative Accuracy ?0.2 mV or ?0.05 % of reading whichever is greater \nEH ORP Modes Yes ISE\nRange 0 to 19999 \nResolution Up to 3 significatn digits\nRelative Accuracy ? 0.2 mV or ?0.05% of reading whichever is greater.\nUnits ppm, M, mg/L%,ppb, none \nCalibration Feature Timed end point, linerar point to point ,\nNon linear selectable auto blank, low\nconcentration range stability\nTemparature \nRange -5 to 105? C, 23 to 221 ?F\n Resolution 0.1 \nRelative Accuracy ?0.1 \nOffset Calibration 1 point \nDatagogging\nMemory 2000 with time and date stamp\nLog Funtion Manuala, ready (include AUTO-READYtm) timed. Log Edit Delete individual points, group of points or all\nInputs pH Electrode BNC, reference pin\nATC Probe 8-pin mini –DIN Output\nRS232, USB Power \nAC Adapter Included- universal, 100-240 VAC\nBattery Power Optional- 4 AAs\nBattery Life 800 hrs.\nInputs Ph Electrode BNC, reference pin ATC Probe 9 –pin Output RS232, USB\n | 21 | 1 | Each |
|---|
| 22 | 22 | Supply of Dessicator with cover & porcelin plate (250 mm) | 22 | 1 | Each |
|---|
| 23 | 23 | Supply of Eye Washer and Shower | 23 | 1 | each |
|---|
| 24 | 24 | Supply of Fire Extinguisher Cap. 6 Kg with Filling Date & date of Expiry | 24 | 1 | each |
|---|
| 25 | 25 | Supply of Weight Box Standard Make Grade F 1 with calibration certificate from NABL Certified laboratory. | 25 | 1 | Each |
|---|
| 26 | 26 | Supply of Digital Thermometer Standard Make with NABL Certified Calibration Certificate | 26 | 1 | Each |
|---|
| 27 | 27 | Supply of Digital Hygrometer Standard Make with NABL Certified Calibration Certificate | 27 | 1 | Each |
|---|
| 28 | 28 | Supply of Cool Box with ice Pack (8 ltr.) | 28 | 2 | Each |
|---|
| 29 | 29 | Supply of First Aid Box | 29 | 1 | Each |
|---|
| 30 | 30 | Supply of Pipette Controller (Genaxy) | 30 | 2 | Each |
|---|
| 31 | 31 | Supply of Auto pipetteMake:- BorosilSupply of Range:- 0.5-10 ml | 31 | 2 | Each |
|---|
| 32 | 32 | Supply of Funnel | 32 | 5 | No. |
|---|
| 33 | 33 | Supply of Pipette (A Grade) (10 ML) | 33 | 2 | No. |
|---|
| 34 | 34 | Supply of Beaker (A Grade) - 50 Ml | 34 | 10 | Each |
|---|
| 35 | 35 | 100 Ml | 35 | 10 | Each |
|---|
| 36 | 36 | 500 Ml | 36 | 2 | Each |
|---|
| 37 | 37 | Supply of Burette A Grade (25 Ml) | 37 | 1 | Each |
|---|
| 38 | 38 | Supply of Burette Digital | 38 | 1 | Each |
|---|
| 39 | 39 | Supply of Measuring Cylinder - 10 Ml | 39 | 2 | Each |
|---|
| 40 | 40 | 50 Ml | 40 | 2 | Each |
|---|
| 41 | 41 | 100 Ml | 41 | 2 | Each |
|---|
| 42 | 42 | Supply of China Dish Silika Gucibiles | 42 | 1 | Each |
|---|
| 43 | 43 | Supply of Watch Glass | 43 | 2 | Each |
|---|
| 44 | 44 | Supply of What man filter papers | 44 | 20 | Each |
|---|