Sales : +91-777 804 8217
| Name of Work: Construction of Drug ware House at Rayagada(Barijhola) (Civil, E.I. and GPH) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | In Ground Floor\nEarth work in excavation of foundation in all kinds of soil within all lead and lifts including dressing the sides, shoring (if nacessary), bailing out water and leveling the bed and depositing the excavated materials away from the work site including all costs of labour,sundries, tools & plants required for the work etc. complete as per direction of Engineer-in-Charge.\n | 268.62 | Cum | |
| 2 | 2 | In Ground Floor\nSupplying, filling in foundation & plinth with sand of approved quality from approved quarry in 23.5cm (9\") thick layers including watering and ramming with cost, conveyance royalties, taxes of all the materials and labour with T&P required for the work etc. complete as per drawing and Technical specification and as directed by the Engineer-in-Charge (Measurement shall be taken on finished compacted section only). | 485.57 | cum | |
| 3 | 3 | In Ground Floor\nCement Concrete of proportion (1:3:6) in foundation and floors using 40mm size hard black Crusher broken granite stone metal of approved quality from approved quarry, free from skin, including hosting, lowering and laying compacting concrete in layers not exceeding 15 cm (6\") thick to required level ramming watering curing etc. including cost, conveyance, royalty and taxes of all materials with all labour with T&P required for the work etc. complete including dewatering if required as per drawing and Technical specification and as directed by the per direction of Engineer-in-Charge. | 105.24 | cum | |
| 4 | 4 | In Ground Floor\nCement Concrete of proportion (1:2:4) using 12mm size hard black broken granite stone chips crusher broken of approved quality from approved quarry including hosting, lowering and laying concrete in layers not exceeding 22cm (9\") thick to required level ramming watering curing, centering & shuttering etc. including cost & conveyance of all materials with all taxes and royality and all labour with T&P required for the work etc. including dewatering if required as per drawing and technical specification and as per direction of Engineer-in-Charge. | 13.84 | cum | |
| 5 | 5 | In Ground Floor\nR.R. H.G. stone masonry in C.M. (1:6) foundation using Hard Black Granite stones of approved size and quality free from weathered skin and from approved quarry including splays cutting, circular molding chamfering & all similar such type of operations with necessary projections, chamfering & corbelling watering and curing etc including cost & conveyance , royalties and taxes of all materials with all labour with T&P required for the work etc. complete as per drawing and Technical specification and as per direction of Engineer-in-Charge. | 65.9 | cum | |
| 6 | 6 | In Ground Floor (Foundation base & footing)\nRCC work of M-20 grade in the following Structural building works using 20mm down graded hard black granite Crusher broken aggregates of approved quality from approved quarry including mixing hoisting lowering laying compacting concrete using concrete mixer, vibrator watering and curing for four weeks centering and shuttering and finishing the exposed surfaces smooth as per relevant clauses of section 1700 of MORT&H specification for Road & Bridge works (4th Revision) including hire and running charges of all machineries including cost, conveyance, royalty and taxes of all materials and labour with T&P required for the work etc. complete as per drawing and Technical Specification and as directed by the Engineer-in- Charge.(Excluding cost of reinforcement & binding wires to be used in the work) | 42.59 | cum | |
| 7 | 6.01 | In Ground Floor\nRCC work of M-20 grade concrete in Grade Beam | 17.61 | cum | |
| 8 | 6.02 | In Ground Floor\nRCC work of M-20 grade concrete in-Column Below Plinth Level | 11.34 | cum | |
| 9 | 6.03 | In Ground Floor\nRCC work of M-20 grade concrete in Column AbovePlinth Level | 15.32 | cum | |
| 10 | 6.04 | In First floor\nRCC work of M-20 grade concrete in Column | 4.75 | cum | |
| 11 | 6.05 | In 2nd Floor\nRCC work of M-20 grade concrete in Column | 1.36 | cum | |
| 12 | 6.06 | In Ground Floor\nRCC work of M-20 grade concrete in Lintel in | 4.62 | cum | |
| 13 | 6.07 | In First floor\nRCC work of M-20 grade concrete in Lintel | 3.04 | cum | |
| 14 | 6.08 | In 2nd Floor\nRCC work of M-20 grade concrete in Lintel | 0.6 | cum | |
| 15 | 6.09 | In Ground Floor\nRCC work of M-20 grade concrete in Chajja | 28.24 | Sqm | |
| 16 | 6.1 | In First floor\nRCC work of M-20 grade concrete in Chajja | 8.92 | Sqm | |
| 17 | 6.11 | In 2nd Floor\nRCC work of M-20 grade concrete in Chajja | 0.93 | Sqm | |
| 18 | 6.12 | In Ground Floor\nRCC work of M-20 grade concrete in Stair Case | 2.55 | cum | |
| 19 | 6.13 | In First floor\nRCC work of M-20 grade concrete in Staircase | 2.55 | cum | |
| 20 | 6.14 | In Ground Floor\nRCC work of M-20 grade concrete in Beams | 17.61 | cum | |
| 21 | 6.15 | In First floor\nRCC work of M-20 grade concrete in Beams | 6.56 | cum | |
| 22 | 6.16 | In 2nd Floor\nRCC work of M-20 grade concrete in Beam | 1.2 | cum | |
| 23 | 6.17 | In Ground floor\nRCC work of M-20 grade concrete in Roof Slab | 59.6 | cum | |
| 24 | 6.18 | In First floor\nRCC work of M-20 grade concrete in Roof slab | 16.75 | cum | |
| 25 | 6.19 | In 2nd Floor\nRCC work of M-20 grade concrete in Roof Slab | 2.47 | cum | |
| 26 | 7 | In Ground Floor\nSupplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-500) (SAIL Only) steel of approved manufacturer as per section 1600 §ion 1900 of MORT&H specification for Road and Bridge works ( 4th revision) including cost, conveyance and taxes of all materials, binding wires 18 to 20 gauge and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. (weight of reinforcement sall be calculated on the basis of IS 1732. wastage, overlaps, couplings, welded joints, space bars, chairs, stays, hangers and annealed steel wires or other method of binding & placing shall not be considered for payment) | 189.61 | Qntl. | |
| 27 | 7.01 | In First Floor\nSupplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-500) (SAIL Only) steel | 38.73 | Qntl. | |
| 28 | 7.02 | In 2nd Floor\nSupplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-500) (SAIL Only) steel | 6.71 | Qntl. | |
| 29 | 8 | In Ground Floor\nFly ash brick masonry in cement mortar (1:6) in Superstructure using bricks of “23cmx11cmx8cm\" size having a crushing strength of not less than 75 Kg. Per Sq. Cm. including immersing in water till saturation before use, Including splays cutting, circular molding, chamfering and corbelling and all similar type of operations with all necessary projections watering and curing etc. complete including cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors as per drawing and Technical specification and as directed by the Engineer-in-Charge. | 88.93 | cum | |
| 30 | 8.01 | In First Floor\nFly ash brick masonry in cement mortar (1:6) in Superstructure using bricks of “23cmx11cmx8cm\" size | 52.97 | cum | |
| 31 | 8.02 | In 2nd Floor\nFly ash brick masonry in cement mortar (1:6) in Superstructure using bricks of “23cmx11cmx8cm\" size | 26.72 | cum | |
| 32 | 9 | In Ground Floor\n2.5 cm (1\") thick grading Concrete in proportion (1:2:2) using 6mm size c.b.h.g chips approved quality from approved quarry over roof slab including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. | 343.07 | sqm | |
| 33 | 9.01 | In First Floor\n2.5 cm (1\") thick grading Concrete in proportion (1:2:2) using 6mm size Crusher Broken hard granite chips approved quality from approved quarry over roof slab…………. | 130.49 | sqm | |
| 34 | 9.02 | In 2nd Floor\n2.5 cm (1\") thick grading Concrete in proportion (1:2:2) using 6mm size Crusher Broken hard granite chips approved quality from approved quarry over roof slab…………. | 19.74 | sqm | |
| 35 | 10 | In Ground Floor\n12 mm (1/2\") thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge. \n | 512.16 | sqm | |
| 36 | 10.01 | In First Floor\n12 mm (1/2\") thick Cement Plaster (1:6) finished smooth to masonry brick walls …...\n | 269.63 | sqm | |
| 37 | 10.02 | In 2nd Floor\n12 mm (1/2\") thick Cement Plaster (1:6) finished smooth to masonry brick walls…..\n | 89.88 | sqm | |
| 38 | 11 | In Ground Floor\n16 mm thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge. \n | 512.16 | sqm | |
| 39 | 11.01 | In First Floor\n16 mm thick Cement Plaster (1:6) finished smooth to masonry brick walls …..\n | 269.63 | sqm | |
| 40 | 11.02 | In 2nd Floor\n16 mm thick Cement Plaster (1:6) finished smooth to masonry brick walls …..\n | 89.88 | sqm | |
| 41 | 12 | In Ground Floor\n6mm thick cement plaster (1:4) over RCC works including deep chipping, finished smooth with proper thickness, watering, curing for required days with cost, conveyance, royality, taxes of all materials and labour with T&P required or the work etc. complete in all respect as per drawing and technical specification and as directed by the Engineer-in-Charge. \n | 400.26 | sqm | |
| 42 | 12.01 | In First Floor\n6mm thick cement plaster (1:4) over RCC works……….\n | 98 | sqm | |
| 43 | 12.02 | In 2nd Floor\n6mm thick cement plaster (1:4) over RCC works……….\n | 13.17 | sqm | |
| 44 | 13 | In Ground Floor\n20mm thick cement plaster (1:6) finished smooth to masonry Stone works with mixture of water proofing compound after raking out joints including watering and curing, cost , conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge. \n | 111.85 | sqm | |
| 45 | 14 | In Ground Floor\nSupplying, fitting, fixing of all types of MS Grills / Gates made of ISI marked standard MS Angles of approved thickness and quality of approved Manufacturers with all required iron and aluminum fittings, including mending to sizes supplying and fixing hinged cleats, sand blocks and fixing of oxidized iron or chromium plated iron aldrops, tower bolts, knobs or rings or handles, hinges, screws and other fittings, etc. complete as per requirement including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge. \n | 1817 | Kg | |
| 46 | 14.01 | In First Floor\nSupplying, fitting, fixing of all types of MS Grills / Gates made of ISI marked standard MS Angles of approved thickness and quality of approved Manufacturers with all required iron and aluminum fittings, ----- | 885 | Kg | |
| 47 | 14.02 | In 2nd Floor\nSupplying, fitting, fixing of all types of MS Door / Shutter made of ISI marked standard MS Angles of approved thickness and quality of approved Manufacturers with all required iron and aluminum fittings…. | 68 | Kg | |
| 48 | 15 | In Ground Floor\nSupplying, fitting and fixing in position well dressed and well seasoned sal wood work framed and fixed (wrought and put up) in choukaths for doors, windows and ventilators including cost of iron works and coal traing 2 coats to wall side faces of choukaths including cost of coaltar, cutting grooves and mending sizes where necessary with cost and conveyance royalities and taxes of all materials and labour with T&P required for the work etc complete in all respect in all floors. | 0.28 | cum | |
| 49 | 15.01 | In First Floor\nSupplying, fitting and fixing in position well dressed and well seasoned sal wood work framed and fixed (wrought and put up) in choukaths for doors, windows and ventilators ---- | 0.21 | cum | |
| 50 | 16 | In Ground Floor\nsupplying,fitting and fixing in position well dressed and well seasoned 32 mm thick piasal wood or local teak wood fully glazed shutters and fixing (wrought and put up) in door windows including cost of iron works and coaltaring two coat wall side faces of chowkhats including costof coaltar cutting grooves and mending size where necessary with cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and technical specification and as directed by the Engineer-in-Charge. \n | 18.38 | sqm | |
| 51 | 16.01 | In First Floor\nsupplying,fitting and fixing in position well dressed and well seasoned 32 mm thick piasal wood or local teak wood fully glazed shutters and fixing (wrought and put up) in door windows incl. cost of iron works & coaltaring two coat wall side faces of chowkhats....... | 14.21 | sqm | |
| 52 | 17 | In Ground Floor\nSupplying, fitting , fixing up window (sliding type) made up aluminum section 9778 as windows frame section No.4095,4096 and 9777,3994 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P excluding cost of glass etc. complete in all respect as per drawing and technical specification and as directed by the Engineer-in-Charge. \n | 46.87 | sqm | |
| 53 | 17.01 | In First Floor\nSupplying, fitting , fixing up window (sliding type) made up aluminum section 9778 as windows frame……. | 32.89 | sqm | |
| 54 | 18 | In Ground Floor\nProviding fitting, fixing of Al. door with OEL anodized Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member with section as 9221 with tapered clip No. 4660 and 12mm thick pre-laminated board fixed on door frame by means the frame to be completed by means of jointing angle No. 1855 including all cost of labour, T&P , hire charges of drilling machine, labour charges etc. complete. including cost of all labour, T&P, hire charges of drilling mechine labour charges etc.complete in all respect as per drawing and technical specification and as directed by the Engineer-in-Charge. \n | 4.74 | sqm | |
| 55 | 18.01 | In First Floor\nProviding fitting, fixing of Al. door with OEL anodized Al. door ……………. | 14.21 | sqm | |
| 56 | 19 | In Ground Floor \nPainting Two coat with any approved S/E paint over a coat of primer to wood / iron works including sand papering, polishing the surface including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge. | 73.16 | sqm | |
| 57 | 19.01 | In First Floor\nPainting Two coat with any approved S/E paint over a coat of primer to wood / iron works including sand papering, polishing the surface …………. | 48.42 | sqm | |
| 58 | 19.02 | In 2nd Floor\nPainting Two coat with any approved S/E paint over a coat of primer to wood / iron works including sand papering, polishing the surface …………. | 4.08 | sqm | |
| 59 | 20 | In Ground Floor \nProviding supplying fitting and fixing Marble tiles flooring on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slurry mixed with pigment to match the shades of tiles including fixing tiles to proper slope / level mending to sizes including cost, conveyance, taxes and royality of all materials with all labour and T&P required for the work etc. complete in all respect as per drawing and technical specification and as directed by the Engineer-in-Charge. | 121.34 | sqm | |
| 60 | 20.01 | In First Floor\nProviding supplying fitting and fixing Marble tiles flooring on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand)………… | 119.75 | sqm | |
| 61 | 21 | In Ground Floor \nProviding supplying fitting and fixing Marble tiles Dadoes on 12mm thick bed of cement mortar 1:3 (1 cement : 3 sand) jointed with neat cement slurry mixed with pigment to match the shades of tiles including fixing tiles to proper slope / level mending to sizes including cost, conveyance, taxes and royality of all materials with all labour and T&P required for the work etc. complete in all respect as per drawing and technical specification and as directed by the Engineer-in-Charge. | 22.94 | sqm | |
| 62 | 21.01 | In First Floor\nProviding supplying fitting and fixing Marble tiles Dadoes on 12mm thick bed of cement mortar 1:3 (1 cement : 3 sand) …………….. | 21 | sqm | |
| 63 | 22 | In Ground Floor\nProviding supplying fitting and fixing Vetrified Industrial tiles flooring on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slurry using premium grade of size 600mmx600mm I.S. standard confirming to IS 13756 having thickness 8mm to 10mm mixed with pigment to match the shade of tiles including rubbing and polishing including fixing tiles to proper slope and level mending to sizes including cost, conveyance, royality, taxes all materials all labopur and T&P required for the work etc. complete in all floors as per standard specification and as directed by the Engineer-in-Charge. | 125.69 | sqm | |
| 64 | 23 | In Ground Floor\n2.5 cm thick A.S flooring with Cement Concrete of proportion (1:2:4) in foundation and floors using 12mm size hard black hand broken granite stone chips of approved quality from approved quarry, free from skin, including hosting, lowering and laying compacting concrete in layers not exceeding 15 cm (6\") thick to required level ramming watering curing etc. including cost, conveyance, royalty and taxes of all materials with all labour with T&P required for the work etc. complete including dewatering if required as per drawing and Technical specification and as directed by the Engineer-in-Charge. | 262.53 | sqm | |
| 65 | 24 | In Ground Floor\nFinishing wall surfaces with cement based putty (water based) of approved quality for making smooth uneven surface to receive painting including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge | 104.45 | sqm | |
| 66 | 24.01 | In First Floor\nFinishing wall surfaces with cement based putty (water based) of approved quality………. | 52.23 | sqm | |
| 67 | 25 | In Ground Floor\nProviding, fitting and fixing of false ceiling with aluminium . anodized T Section No. 3215 with the 2'-00\" center to center, L section No. 1705 upto 15micron on 4 walls to be fixed by means of steel screw and PVC plug & the aluminium grid 2\" x 2\" expanded from ceiling etc. complte including cost of all materials all labopur and T&P required for the work etc. complete as per standard specification and direction of Engineer-in-charge. | 37.18 | sqm | |
| 68 | 25.01 | In First Floor\nProviding, fitting and fixing of false ceiling with aluminium . anodized T Section……….. | 18.59 | sqm | |
| 69 | 26 | In Ground Floor\nProviding, Fixing and fitting of design carnis , including cost, conveyance of all materials with labour and T&P required for the work etc.complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. | 35.15 | Rmt | |
| 70 | 26.01 | In First Floor\nProviding, Fixing and fitting of design carnis……….. | 17.57 | Rmt | |
| 71 | 27 | In Ground Floor \nDistempering Two coats to walls over a coat of primer with distemper of approved shade on prepared surface of new works to give a even shade with cost conveyance royalties and taxes of all the materials and all labour with T&P required for the work etc. (Including cost of distemper) complete in all respect in all floors as per drawing and Technical Specification and as directed by the Engineer-in- Charge | 1075.77 | sqm | |
| 72 | 27.01 | In First Floor \nDistempering Two coats to walls over a coat of primer with distemper of approved shade on prepared surface of new works……. | 400.86 | sqm | |
| 73 | 27.02 | In 2nd Floor \nDistempering Two coats to walls over a coat of primer with distemper of approved shade on prepared surface of new works……. | 47.69 | sqm | |
| 74 | 28 | In Ground Floor \nFinishing wall surfaces with Weather coat of two coats over a coat of Primer of approved shade on new works two coats to give an even shade over the prepared surfaces including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge. | 433.31 | sqm | |
| 75 | 28.01 | In First Floor \nFinishing wall surfaces with Weather coat of two coats over a coat of Primer of approved shade on new works two coats to give an even shade over the prepared surfaces….. | 219.95 | sqm | |
| 76 | 28.02 | In 2nd Floor \nFinishing wall surfaces with Weather coat of two coats over a coat of Primer of approved shade on new works two coats to give an even shade over the prepared surfaces…… | 144.33 | sqm | |
| 77 | 29 | In Ground Floor \nSupplying fitting and fixing of Stainless Steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mmx32mmx 2mm @ 0.90mtr C/C and Stainless square pipe bracing of size 32mmx 32mmx 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing,etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. | 6.1 | Rmt | |
| 78 | 29.01 | In First Floor \nSupplying fitting and fixing of Stainless Steel of 304 grade in hand railing………………. | 12.19 | Rmt | |
| 79 | 30 | Int.PH Section\nSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC pipes conforming to ASTM-D-1785/89 of the following nominal bore, tube fittings and clamps including making the wall good. ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.---------- \n(20mm dia PVC ASTM Pipe (Sch-80)) In Ground Floor | 20 | Mtrs | |
| 80 | 30.01 | (20mm dia PVC ASTM Pipe (Sch-80)) in First Floor | 20 | Mtrs | |
| 81 | 30.02 | 25mm dia PVC ASTM Pipe (Sch-80) ----- In Ground Floor | 50 | Mtrs | |
| 82 | 30.03 | 25mm dia PVC ASTM Pipe (Sch-80)Ground Floor ------ In First Floor | 20 | Mtrs | |
| 83 | 31 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.\n15mm dia CP angle stop cock (Jaquar)CON-CHR-059KN | 8 | Each | |
| 84 | 31.01 | 15mm dia CP short body bib cock (Jaquar)CON-CHR-047KN | 2 | Each | |
| 85 | 31.02 | 15mm dia CP long body bib cock (Jaquar Make)CON-107KN | 2 | Each | |
| 86 | 31.03 | 15mm dia CP two way bib cock (Jaquar)CON-041KN | 2 | Each | |
| 87 | 31.04 | 20mm dia CP concealed stop cock (Jaquar Make)CON-089KN | 1 | Each | |
| 88 | 31.05 | Wall mixer with coinnector for hand shower arrangement with connecting legs,wall flavnges & wall bracket for hand shower(Con-267KN) | 1 | Each | |
| 89 | 31.06 | 25mm dia brass full way valve (Shakti make) | 4 | Each | |
| 90 | 31.07 | 25mm dia CP Health Faucet (Jaquar Make)ALD - CHR - 565 | 2 | Each | |
| 91 | 31.08 | 15mm CP Extension piece | 14 | Each | |
| 92 | 31.09 | 125mm CP grating | 7 | Each | |
| 93 | 31.1 | 15mm size C.P. flange | 14 | Each | |
| 94 | 32 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width Fly ash Bricks in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge\n2000 liters capacity PVC water storage tank (Roof of First Floor) | 1 | Each | |
| 95 | 33 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. -------------- \nIn Ground Floor | 6 | Each | |
| 96 | 33.01 | In First Floor | 4 | Each | |
| 97 | 34 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and as per direction of Engineer-in-charge.\nIn Ground Floor | 2 | Each | |
| 98 | 34.01 | In First Floor | 2 | Each | |
| 99 | 35 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of Engineer-in-charge.\nIn Ground Floor | 15 | Mtrs | |
| 100 | 35.01 | In First Floor | 10 | Mtrs | |
| 101 | 36 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) | 30 | Mtrs | |
| 102 | 36.01 | 75mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) | 15 | Mtrs | |
| 103 | 36.02 | 110mm U-PVC ' P ' Trap(Ori Plast/Finolex/Supreme Make) | 3 | Each | |
| 104 | 36.03 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) | 4 | Each | |
| 105 | 36.04 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) | 4 | Each | |
| 106 | 36.05 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) | 4 | Each | |
| 107 | 36.06 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) | 4 | Each | |
| 108 | 36.07 | 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) | 4 | Each | |
| 109 | 36.08 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) | 10 | Each | |
| 110 | 37 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge European water closet with 'p' trap plain(Hindware/Parryware/Neycer make) | 2 | Each | |
| 111 | 38 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 580mm size Orissa pan (Hindware/Parryware/Neycer make) | 1 | Each | |
| 112 | 39 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) | 3 | Each | |
| 113 | 40 | Supplying all materials,labour,T&P and fixing Flat back lipped wall ( Bowl Type ) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge. | 1 | Each | |
| 114 | 41 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge \n550mmx400mm W.H.basin (Hindware /Parryware /Neycer make) with 15mm dia C.P.pillar cock (Plaza make) with Pedestal\n | 3 | Each | |
| 115 | 42 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge\n25mm X 600mm long CP Towel Rail | 3 | Each | |
| 116 | 42.01 | Towel ring | 3 | Each | |
| 117 | 43 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge\nCP soap holder | 6 | Each | |
| 118 | 44 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge.\n½” x 5” CP Shower (Plaza Deluxe Make) | 1 | Each | |
| 119 | 45 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails. | 3 | Each | |
| 120 | 46 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. 600mmx450mm size B.E mirror (swivelled type) | 3 | Each | |
| 121 | 47 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge | 2 | Each | |
| 122 | 48 | Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge. | 2 | Each | |
| 123 | 49 | Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. | 1.25 | Cum | |
| 124 | 50 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. Ground Floor | 1.25 | Cum | |
| 125 | 51 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ----------------- Ground Floor | 0.83 | Cum | |
| 126 | 51.01 | In First Floor | 0.51 | Cum | |
| 127 | 52 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 30cmx30cm special printed series to be pre-approved by the Engineer-in-charge ) Kajaria tile 40cmx40cm Ground Floor | 8.35 | Sqm | |
| 128 | 52.01 | First Floor | 5.14 | Sqm | |
| 129 | 53 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.------------ Ground Floor | 39.68 | Sqm | |
| 130 | 53.01 | In First Floor | 19.93 | Sqm | |
| 131 | 54 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 30cmx45cm special plain / printed series to be pre-approved by the Engineer-in-charge ) Kajaria tile 40cmx25cm ------------ In Ground Floor | 39.68 | Sqm | |
| 132 | 54.01 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) …\nIn First Floor | 19.93 | Sqm | |
| 133 | 55 | Factory made single leaf rigid FRP(alternately called GRP) sanwhch composite door shutter of 32mm thick laminated ith two GRP skins with wood grain finish fabricated using UV-stabilised Isothealica Gelcoat and one layer of 450 gsm E-glass chopped starand mat (CSM) impregnated with orthopthalic palyester resin. The thikness of the skins shall not be less that 1.50mm expanded polyestyrone(EPS) stuctural foam panel of 29 mm thickness and a density of 20Kg/cu.mtr shall be used as core material .Wooden reinforcements made of seasoned sal wood reinforements for fitting the metal fittings such as tower bolts ,aldrops,handles etc. shall be provided .A Strictira; adehsive compatible with(EPS) foam shall be used for bending the core material,the sal wood reiforcements and the skins.The materials and process for manufacturing the door shutters shall conform to RC-TIFAC composites Design centre's standars and specifications and the door shutters tested in conformation to IS:40250-1998.The finish of door shutter will be plain colour white/Lvory/beige/Light grey/Mahogany/Teak wood of any other colour using high quality pigments .Three heavy whight mild steel butt hinges typpe-I(ISI-marked) size 100 mm are to be fitted on one side of shutter. --------- Door | 7.88 | Sqm | |
| 134 | 56 | Factory made FRP (alternately called GRP) door frame of sixe75mmX100 mm fabricated using E-Glass chopped strand Mat(CSM) U.V stabilised inopthalic Gelcoat and impregnated with inopthalic resin.The thickness of the GRP sikns shall no be less that 2.00 mm .The door frame consist of foru segments which are provided with plug-in-socket arrangement in-site in the ,ould .The segments are plugged in and are joined together by means of screw . The GRP frame shall be provided with wooedn rainforcement of six locations for high screw holding capacity for fixing metallic hold fast and shall be consolidated by filling with medium destity foam/Plaster of paris with fibre reinforcement,Six numbers of 260mm X 25mm X 5 mm size 'S' shaped M.S flat hold fast shall be provided with the frame .The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design centre's stanards and specifications.The finish of door rrame will be plain colour white/Lvory/Beige/Light grey Golden brown Mahogany/Teak wood sand stone/Champagne /Pastel blue or any other colour using high quality pigments cimplete in all respect as per specification and direction of the Engineer in Charge. | 30 | Rmt | |
| 135 | 57 | Supplying all materials labor T&P and fitting & fixing 40mm to 50mm thick marble partition tile including cutting grooves and mending good the damages with cement plaster (1:3) jointed with neat cement slury mixed with pigments to match the shades of the tile including rubbing and polishing all complete as per specification and direction of the Engineer in charge. | 0.72 | Sqm | |
| 136 | 58 | Ext. PH Works\nSupplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 110mm dia P.V.C. pipe | 15 | Mtrs. | |
| 137 | 59 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge | 1 | Each | |
| 138 | 60 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , Fly ash Bricks in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge Inside size 76cmx76cmx46cm with 18” dia RCC MH cover | 2 | Each | |
| 139 | 61 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover ) | 1 | Each | |
| 140 | 62 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. | 1 | Each | |
| 141 | 63 | 1 No 20 Users septic tank of size 2.30m x 1.10m x 2.10m Internal size\nEarth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge | 11.73 | Cum. | |
| 142 | 64 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. | 4.69 | Cum. | |
| 143 | 65 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. | 2.92 | Cum. | |
| 144 | 66 | Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete. | 1.17 | Cum. | |
| 145 | 67 | Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete. | 0.91 | Cum. | |
| 146 | 68 | Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site. | 0.45 | Cum. | |
| 147 | 69 | Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. | 0.4 | Qntl. | |
| 148 | 70 | Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor. RCC floor, roof slab chhaja up to 4.430 m height | 4.29 | Sqm. | |
| 149 | 71 | Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:4) in foundation and plinth including watering and curing and lead of materials to site. | 6.07 | Cum. | |
| 150 | 72 | Supplying all materials labour T&P and providing 12mm thick C.P (1:4) including watering curing and conveyance of all materials to site. | 22.09 | Sqm. | |
| 151 | 73 | Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site. Same as plastering | 22.09 | Sqm. | |
| 152 | 74 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. | 1.17 | Cum. | |
| 153 | 75 | Roof Top Rain Water Harvesting System\nSupplying all materials, labour, T&P and fitting and fixing U-PVC rain water pipe /ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge 110mm dia U-PVC Rain water pipe (Finolex/Supreme/Ori Plast Make) Type A\n | 65 | Mtr | |
| 154 | 75.01 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) | 6 | Each | |
| 155 | 75.02 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) | 6 | Each | |
| 156 | 75.03 | 110mm dia GI clamp | 30 | Each | |
| 157 | 75.04 | 125mm dia CP grating | 6 | Each | |
| 158 | 75.05 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) | 10 | Each | |
| 159 | 76 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 100mm dia P.V.C. pipe | 10 | Mtr. | |
| 160 | 77 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , fly ash brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge \nInside size 760mmx760mmx460mm with 18” dia RCC MH cover | 2 | Each | |
| 161 | 78 | Filter Media\nSupplying all materials, labour, T&P and providing 15cm thick layer of coarse sand, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. | 0.17 | Cum | |
| 162 | 79 | Supplying all materials, labour, T&P and providing 15cm thick layer of 2 to 4mm pea sized boulders/gravels other than granite including watering, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. | 0.17 | Cum | |
| 163 | 80 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. | 2 | Each | |
| 164 | 81 | Electrical\nRecessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with S.P 5/6Amp, one way modular switch ISI marked(L&T/crabtree/ Havells/ ROMA/ SIEMENS/ Finolex) and ceiling rose ISI marked mounted on Modular GI box of 18SWG having modular base & cover of suitable size with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) Group-A. L.P.-17 F.P.- C.B.- Grnd floor | 17 | Nos. | |
| 165 | 82 | Group-B. L.P.- 40 F.P.-24 C.B.- Grnd floor | 64 | Nos. | |
| 166 | 83 | Group-C L.P.- 23 F.P.-20 C.B.- Grnd floor | 43 | Nos. | |
| 167 | 84 | Group-A. L.P.-10 F.P.- C.B.- 1st floor | 10 | Nos. | |
| 168 | 85 | Group-B. L.P.-22 F.P.-05 C.B.- 1st floor | 27 | Nos. | |
| 169 | 86 | Group-C L.P.- 16 F.P.-06 C.B.- 1st floor | 22 | Nos. | |
| 170 | 87 | Recessed wiring for 5/6Amp modular Socket outlet with 2x1.5mm2 FR PVC insualted single core multistand copper conductor of ISI marked in recess 20mm dia Non-metalic PVC flexible conduit with piano type switch,phenolic laminated sheet suitable size ISI marked on modular GI box and earthing point with 1x1.5sqmm FR PVC insulated single core multistand copper conductor for loap earthing etc.as required(make of wire-Finolex/L&T/Anchor/ Havels/V-Guard) Ground Floor | 2 | Nos. | |
| 171 | 88 | On Existing board. Ground Floor | 10 | Nos | |
| 172 | 89 | Group-A. 1st floor | 4 | Nos | |
| 173 | 90 | On Existing board. 1st floor | 8 | Nos | |
| 174 | 91 | Recessed submain wiring along with earth wire with the following sizes of PVC insualted single core multistand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non-metalic heavy duty flexible conduit 1.6mm in recess PVC conduit as required (make of wire-Finolex /L&T/ Anchor/ Havels/ V.Guard) \na)1x1.5mm2 (1.19.2.SOR-17) Inverter wiring Ground Floor | 160 | Mtrs. | |
| 175 | 92 | b)2x2.5mm2+1x1.5mm2(1.8.2.SOR-17) Ground Floor | 192 | Mtrs. | |
| 176 | 93 | c)2x4mm2+1x1.5mm2 (1.8.3.SOR-17) Ground Floor | 298 | Mtrs. | |
| 177 | 94 | e)4x6mm2+ 2x2.5mm2(1.8.11.SOR-17) Ground Floor | 62 | Mtrs. | |
| 178 | 95 | a)1x1.5mm2(1.19.2.SOR-17) Inverter wiring 1st floor | 96 | Mtrs. | |
| 179 | 96 | b)2x2.5mm2+1x1.5mm2(1.8.2.SOR-17) 1st floor | 135 | Mtrs. | |
| 180 | 97 | c)2x4mm2+1x1.5mm2 (1.8.3.SOR-17) 1st floor | 75 | Mtrs. | |
| 181 | 98 | d)4x6mm2 +2x2.5mm2(1.8.11 SOR-17) 1st floor | 61 | Mtrs. | |
| 182 | 99 | Supplying and fixing Modular G.l. box of 18 SWG on surface or in recess with Modular base & cover for module in front including providing and fixing 6pin 15/16Amp modular socket outlet and SP 15/16Amp oneway modular switch (Power Plug) with indicator connection, painting etc as required. Ground Floor | 24 | Nos | |
| 183 | 100 | Supplying and fixing Modular G.l. box of 18 SWG on surface or in recess with Modular base & cover for module in front including providing and fixing 6pin 15/16Amp modular socket outlet and SP 15/16Amp oneway modular switch (Power Plug) with indicator connection, painting etc as required. ----------1st Floor | 4 | Nos | |
| 184 | 101 | Supplying and fixing of stepped type modular regulator of ISI marked(ROMA/Crabtree/L&T/ Legrand) on Modular G.l. box of 18 SWG on surface or in recess with suitable size Modular base & cover module in front including providing and fixing connection, painting etc as required.(For light plugs to be used in non residential buildings) Ground Floor | 42 | Nos. | |
| 185 | 102 | Supplying and fixing of stepped type modular regulator of ISI marked(ROMA/Crabtree/L&T/ Legrand) on Modular G.l. box of 18 SWG on surface or in recess with suitable size Modular base & cover module in front including providing and fixing connection, painting etc as required.(For light plugs to be used in non residential buildings) ------------- 1st Floor | 10 | Nos. | |
| 186 | 103 | S/F of 20W/18W LED batten light of Crompton/Havells make. Ground Floor | 39 | Nos. | |
| 187 | 104 | S/F of 20W/18W LED batten light of Crompton/Havells make. -------- 1st Floor | 20 | Nos. | |
| 188 | 105 | S/F.of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of Ceiling rose. Ground Floor | 1 | Nos. | |
| 189 | 106 | S/F.of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of Ceiling rose. --------- 1st Floor | 2 | Nos. | |
| 190 | 107 | S/F of 9W/10W LED lamp of havells/Crompton Ground Floor | 1 | Nos. | |
| 191 | 108 | S/F of 9W/10W LED lamp of havells/Crompton ------- 1st Floor | 2 | Nos. | |
| 192 | 109 | S/F.of 48\"A.C.Ceiling fans complete with ISI marked (Usha Ergo/Usha vetra plus/ /Bajaj-Elegance (Ivory)/ crompton Aura plus(ivory) make including all accessories & connection as per direction of Engineer-in-charge. Ground Floor | 42 | Nos. | |
| 193 | 110 | S/F.of 48\"A.C.Ceiling fans complete with ISI marked (Usha Ergo/Usha vetra plus/ /Bajaj-Elegance (Ivory)/ crompton Aura plus(ivory) make including all accessories & connection as per direction of Engineer-in-charge. ---------- 1st floor | 10 | Nos. | |
| 194 | 111 | S/F of 300mm metal exhaust fan with wall cutting masonary work including all accessories of USHA(Jet Dix)/ Bajaj (Bahar)/ Crompton make & connection as per direction of Engineer-in-charge. Ground Floor | 2 | Nos. | |
| 195 | 112 | S/F of 300mm metal exhaust fan with wall cutting masonary work including all accessories of USHA(Jet Dix)/ Bajaj (Bahar)/ Crompton make & connection as per direction of E.I.C ---- 1st floor | 1 | Nos. | |
| 196 | 113 | S/F of 20AMP 240V SPN Industrial type socket outlet with two pole and earth metal enclosed top along with 20amp \"C\" series SP MCB in sheet steel enclosedn on surface or in recess with chained metal cover for the circuit oulet and complete connection as per direction of Engineer-in-charge. Ground Floor | 26 | Nos. | |
| 197 | 114 | S/F of 20AMP 240V SPN Industrial type socket outlet with two pole and earth metal enclosed top along with 20amp \"C\" series SP MCB in sheet steel enclosedn on surface or in recess with chained metal cover for the circuit oulet and complete connection as per direction of Engineer-in-charge. ----------- 1st floor | 2 | Nos. | |
| 198 | 115 | Supplying and fixing of Modular G.l. box for suitable module on surface or in recess with Modular base & cover and blanking plate ( if required) in front including providing and fixing of 25AMP DOL starter (ROMA/ Crabtree/Havells make) of modular type switch, connection, painting etc as required as per the direction of E.I.C. Ground Floor | 26 | Nos. | |
| 199 | 116 | Supplying and fixing of Modular G.l. box for suitable module on surface or in recess with Modular base & cover and blanking plate ( if required) in front including providing and fixing of 25AMP DOL starter (ROMA/ Crabtree/Havells make) of modular type switch, connection, painting etc as required as per the direction of E.I.C.. --- 1st floor | 2 | Nos. | |
| 200 | 117 | S/F.of Computer board consisting of 2Nos 5/6AMP modular socket & modular switch including suitable size of GI modular box and modular base &cover (ROMA/ Crabtree/ Havells/L&T)complete with connection as per the direction of Engineer-in-Charge. Ground Floor | 6 | Nos. | |
| 201 | 118 | S/F.of Computer board consisting of 2Nos 5/6AMP modular socket & modular switch including suitable size of GI modular box and modular base &cover (ROMA/ Crabtree/ Havells/L&T)complete with connection as per the direction of Engineer-in-Charge ----- 1st floor | 2 | Nos. | |
| 202 | 119 | S/F 1x60W 5700K LED street light made up of pressure die cast housing with toughned glassindividual high powered LEDs with secondary optics ,IP66 protection Havells make(ENDURA PEARL PLUS )/Crompton NEXUS+ as per direction of Engineer in charge.( 3 nos. for other building) 1st floor | 1 | Nos. | |
| 203 | 120 | S/F 1x45W 5700K LED street light made up of pressure die cast housing with toughned glassindividual high powered LEDs with secondary optics ,IP66 protection Havells make(ENDURA PEARL PLUS )/Crompton NEXUS+ as per direction of Engineer in charge. 1st floor | 13 | Nos. | |
| 204 | 121 | S/F of 4way TPN(4+12) Double door D. Box (Havells/ L&T/Hager) with 50Amp TPN, 3x40Amp DP MCB & 6x(6-32)A SP MCB of Havells/ L&T/Hager make including all accessories and connection As aper direction Engineer-in-Charge. Ground Floor | 3 | Nos | |
| 205 | 122 | S/F of 12 way Double door D. Box (Hager/L&T/Havells) with 40Amp TP,9x(6-32Amp)SP MCB of Hager/L&T/ Legrand make including all accessories and connection. as per direction Engineer-in-Charge. 1st floor | 1 | Nos. | |
| 206 | 123 | S/F of 1x15W surface celing LED light made up of pressure die cast housing with secondary optics ,IP66 protection with fixing on ceiling of Havells make(ENDURA NEO DL SURFACE) or Equivalent of Crompton/Philips.as per direction of Engineer-in-charge. Ground Floor | 89 | Nos. | |
| 207 | 124 | S/F of 1x15W surface celing LED light made up of pressure die cast housing with secondary optics ,IP66 protection with fixing on ceiling of Havells make(ENDURA NEO DL SURFACE) or Equivalent of Crompton/Philips.as per direction of En.I.C ------ 1st Floor | 10 | Nos. | |
| 208 | 125 | S/F1x15W LED of 3700K Warm white/6000K coolday white recess mounted downlighter made up of pressure die cast Al. heat sink and PC diffuser in white powder coated finish with integrated driver with ceiling cutting and fixing, Havells make(TRIM LED LED PANEL ROUND/BLAZE ROUND)/ Crompton(CROM ROUND) OR Equivalent model of Philips make as per direction of E.I.C ------ Ground Floor | 12 | Nos. | |
| 209 | 126 | S/F1x15W LED of 3700K Warm white/6000K coolday white recess mounted downlighter made up of pressure die cast Al. heat sink and PC diffuser in white powder coated finish with integrated driver with ceiling cutting and fixing, Havells make(TRIM LED LED PANEL ROUND/BLAZE ROUND)/ Crompton(CROM ROUND) OR Equivalent model of Philips make as per direction of E.I.C ------ 1st Floor | 6 | Nos. | |
| 210 | 127 | S/F.of Special earthing complete with provision of 600x600x3mmthick or (2ft x 2ft) copper plate, 38/40mm dia 3mtr long G.I.pipe , 25x3mm thick Cu.flat charcoal and salt,funel,earthpit chamber with masonary work including all accessories and connection as per direction of Engineer-in-charge. Ground Floor | 1 | Nos. | |
| 211 | 128 | Supply and laying of 25mmx5mm copper strip on surface or in recess for connection etc as required.(Connection to be made from special earth electrode to Main panel )as per direction of Engineer-in-charge. Ground Floor | 10 | Mtrs. | |
| 212 | 129 | S/f.of Standard earthing with G.I.earth pipe(With charcoal and salt) (Sl.No.3.2.of SOR-2017) as per direction of Engineer-in-charge. Ground Floor | 2 | Nos. | |
| 213 | 130 | Extra for using salt and charcoal for G.I or copper pipe earth electrode as required as per direction of Engineer-in-charge. Ground Floor | 2 | Nos | |
| 214 | 131 | P/F of 6 SWG G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/ submain wiring/cable as required( Ground Floor | 10 | mtrs | |
| 215 | 132 | S/F of 16 sq.mm 4 Core Alluminium, armoured LT power Cable of XLPE insulated 650/1100 grade(make-Havells/ Polycab) Ground Floor | 80 | mtrs | |
| 216 | 133 | S/F of 50 sq.mm 3&1/2 Core Alluminium, armoured LT power Cable of XLPE insulated 650/1100 grade(make-Havells/ Polycab) Ground Floor | 60 | mtrs | |
| 217 | 134 | Electrical Inspection charges for Building Ground Floor | 1 | Each | |
| 218 | 135 | S/F of 200Amp Panel Board size 36\"×24\"×12\" with powder coat made of SWG Sheet with designing (i)200A, 36KA, 4pole MCCB of Adjustable thermal and fixed magnetic setting of L&T/Hager/Legrand-1 nos (ii)200 Amp TPN Alluminium bus bar, (iii)63A TPN MCB(L&T/Hager/Havells)-4nos. (iv)40A DP MCB (L&T/Hager/Havells)-2nos. . (v)Digital Voltmeter, Ammeter, Selector switch as per direction of Engineer-in-charge. (vii) 200Amp,415V Kitkat rewirable (porcelain Fuse carrier &Base) -3 Nos. (viii)250AMp 4 pole Changeover of L&T/Hager/Legrand make; Ground Floor | 1 | Each |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail