Water Resources Department-WRD has published Renovation And Modification Work Of Laboratory Building Material Testing Division Id And R Sinchai Bhawan Jln Marg , Jaipur Renovation And Modification Work Of Laboratory Building , Material Testing Division , Id And R , Sinchai Bhawan Jln Marg , J. Submission Date for this Tender is 26-11-2019. Building Repair Tenders in Sinchai Bhawan, Jaipur Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work: Renovation and modification work of laboratory building, Material Testing Division, ID&R, Sinchai Bhawan, JLN Marg, Jaipur | |||||
---|---|---|---|---|---|
Sl. No. | Perticulars of Item | Item Code / Make | Quantity | Units | |
1 | 0.9 | Civil work | BI01010001010000000000000515BI0100001112 | ||
2 | 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. | BI01010001010000000000000515BI0100001113 | 450 | Sqm |
3 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed: \n(a) All kind of soils | BI01010001010000000000000515BI0100001114 | 270 | Cum |
4 | 3 | Add extra for carriage of material upto 100m beyond initial carriage \n(a) earth ,sand ,lime, morrume,manure or sludge | 270 | Cum | |
5 | 3.1 | (b) building rubbish stone material(grit and ballast etc.) | 2 | Cum | |
6 | 4 | Making the opening in masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground.\nFor door/windows/clerestory windows | 5.1 | Sqm | |
7 | 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. | 2 | Cum | |
8 | 6 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to linth level. M10 grade Nominal Mix\n1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). | 3 | Cum | |
9 | 7 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to linth level. M15 grade Nominal Mix\n1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). | 16.2 | Cum | |
10 | 8 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 4 (1 cement : 4 coarse sand) | 4 | Cum | |
11 | 9 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 . Cement mortar 1 : 4 (1 cement : 4 coarse sand) | 60 | Sqm | |
12 | 10 | Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc complete fine finish: 12 mm thick | 175 | Sqm | |
13 | 11 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and lastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : With cement mortar 1 :4 ( 1 cement : 4 coarse sand) | 50 | Sqm | |
14 | 12 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :\n(a) Sand or other approved stone 25mm thick. | 9.3 | Sqm | |
15 | 12.1 | (b) Sand or other approved stone 50mm thick. | 2.34 | Sqm | |
16 | 13 | Supplying and fixing stone lintels/bed plates of approved quarry rough dressed in cement mortar 1:4 : Upto 15 cm. thick. | 0.17 | Cum | |
17 | 14 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm | 27 | Sqm | |
18 | 15 | P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm | 75 | Sqm | |
19 | 16 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : 35 mm thick . Commercial Veneer both side | 7.2 | Sqm | |
20 | 17 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured)\nOver item no. 16 | 7.2 | Sqm | |
21 | 18 | Extra for providing vision panel not exceeding 0.1 Sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : | 2 | Each | |
22 | 19 | Providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutter 25 mm to 40 mm thick SS wire gauge 14 mesh x 24 gauge | 4.8 | Sqm | |
23 | 20 | Providing and fixing in CM 1 : 4 double paitam (rebated) stone door window and ventilator frames of approved quarry : Size 125 x 100mm | 16.2 | Mtr | |
24 | 21 | Renewing glass panes with putty and nails wherever necessary Float glass panes of thickness 4mm | 16 | Sqm | |
25 | 22 | Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete | 4 | Sqm | |
26 | 23 | Repair of rolling shutter with replacement of shutter spring incl. removal of old spring in the existing rolling shutter incld. Cost of new spring | 1 | Each | |
27 | 24 | Refebrication work with existing steel work including cutting, welding & refebrication as per requirement with fixing at site complete as per direction of Engineer In charge | 100 | Kg | |
28 | 25 | Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. | 12 | Sqm | |
29 | 26 | Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx 1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge | 22 | Sqm | |
30 | 27 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) | 3 | Sqm | |
31 | 28 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: \n(a) Old work (one or more coats) | 4500 | Sqm | |
32 | 28.1 | (b) New work (Two or more coats applied @ 3.84 kg/10 sqm). | 176 | Sqm | |
33 | 29 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding \nOld work (One or more coats ) | 700 | Sqm | |
34 | 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :\n(a) Two or more coats on new work | 75 | Sqm | |
35 | 30.1 | (b)One or more coats on old work. | 525 | Sqm | |
36 | 31 | Structural steel work riveted, bolted or welded in built up section, trusses and framed work, including cutting, hoisting( height upto 10m) fixing in position and applying a priming coat of approved steel primer all complete. | 250 | Kg | |
37 | 32 | Providing & fixing calcium silicate ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( alvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main 6 mm thick | 25 | Sqm | |
38 | 33 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. | 550 | Kg | |
39 | 34 | Supply of 6 mm thick tapered edge calcium silicate board/tile | 47.5 | Sqm | |
40 | 35 | Supply of Carpenter 1st class | 10 | Per Day | |
41 | 36 | Supply of Beldar | 10 | Per Day | |
42 | 37 | Supply of Enamel paint | 5 | Ltr. | |
43 | 38 | Supply of Painter | 10 | Per Day | |
44 | 39 | Supply of Mason/ Painter/ Carpenter/ Electrician/ Black smith/ Plumber | 20 | Per Day | |
45 | 40 | Construction of Open Surface Drain with 112mm thick brick masonry in CM 1:4,110mm thick base concrete 1:5:10, 37mm thick M-15 grade C.C. flooring ,12mm 1:4 cement plaster on all exposed faces of walls including top surface excavation & disposal of earth complete as per approved design/drawing: 250mm drain,300mm Av. depth | 175 | Mtr. | |
46 | 41 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 110 mm dia | 120 | Mtr. | |
47 | 42 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : WVC Lab sink (IS:2556 mark) size 530 x 430 x 180 mm | 5 | Each | |
48 | 43 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: P.V.C.heavy duty, 15mm nominal bore. | 8 | Each | |
49 | 44 | P&F GI pipes (internal work) with GI fittings excluding union (IS 1239 mark) & MS claps including cutting and making good the walls and floors exposed on wall 15 mm dia nominal bore "B" class | 30 | Mtr. | |
50 | 44.1 | Electrical work | BI01010001010000000000000515BI0100001124 | ||
51 | 45 | P&F of Heavy duty capacitor start, Double ball bearing 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required. 300mm sweep (900/1400 RPM) | BI01010001010000000000000515BI0100001125 | 5 | Each |
52 | 46 | P & F double ball bearing capacitor start, aluminium body & blade ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 1200 mm sweep | 14 | Each | |
53 | 47 | P & F of capacitor start, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required. 400 mm sweep(Oscillating type) | 8 | Each | |
54 | 48 | P & F box type fluorescent tube fitting fabricated from CRCA sheet and finished with powder coating / stove enamelled paint complete with accessories (Low Loss Copper Choke, starter, starter seat) / Electronic Choke with terminal block duly prewired with copper conductor including making connection, testing etc. as required( without tube). 1 X 28 Watts with EB | 20 | Each | |
55 | 49 | P & F Fluorscent tube rod in existing fixtures as required, T5 lamps 28 watts | 20 | Each | |
56 | 50 | SITC of Air Cooled split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 4 Mtr (IDU to ODU), R-22/R-410 Refrigerant, Remote, suitable for 400/230V +10% of 50 Hz ,1 /3 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / reciprocating / rotary compressor as specified. Hi Wall/Ceiling Wall Split 1.5 TR with 5 star rating of BEE | 2 | Each | |
57 | 51 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.\n(a)1x1.5 sqmm | 3000 | Mtr. | |
58 | 51.1 | (b)1x2.5 sqmm | 1500 | Mtr. | |
59 | 52 | P & F 18 SWG Sheet steel boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surface or in recessed as required.\n(a) 175mm x 100mm x 60mm | 25 | Each | |
60 | 52.1 | (b) 250mm x 100mm x 60mm | 40 | Each | |
61 | 53 | Labour charges for dismantling of surface PVC/ Steel conduit including wiring in conduit, conduit fittings and depositing the same with listing of material in store. | 400 | R.Mtr | |
62 | 54 | Labour charges for dismantling of surface/ recessed switch board of any size and depositing the same with listing of material in store. | 100 | Each | |
63 | 55 | Labour charges for dismantling of switch accessories like switch, socket, ceiling rose, holder and depositing the same with listing of material in store. | 50 | Each | |
64 | 56 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. 4.8 mm thick | 4 | Sqm | |
65 | 57 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required.\na) 20mm | 450 | R.Mtr | |
66 | 57.1 | b) 25mm | 225 | R.Mtr | |
67 | 58 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. Single pole MCB 6 A to 32 A rating | 40 | Each | |
68 | 59 | P&F 240/415 V isolator conforming to IS:13947-III/ IEC 60947-3 on existing board / sheet including making connections, testing etc. as required.\na) Triple pole isolator 63A rating | 2 | Each | |
69 | 59.1 | b)Triple pole isolator 100A rating | 2 | Each | |
70 | 60 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. Single door (Three phase) Per phase isolation 2+12 Way | 4 | Each | |
71 | 61 | P & F ISI marked (IS :3854) 6 amp. flush type switch including cutting hole in tile and making connection testing etc. as required. | 150 | Each | |
72 | 62 | P & F ISI marked (IS :3854) 16 amp. flush type switch including cutting hole in tile and making connection testing etc. as required. | 50 | Each | |
73 | 63 | P & F of 3 pin 6 amp. flush type socket including cutting hole in tile and making connection testing etc. as required. | 50 | Each | |
74 | 64 | P & F 3/6 pin 16 amp flush type socket including cutting hole in tile and making connection testing etc. as required. | 50 | Each | |
75 | 65 | P & F socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. | 20 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy