Tamil Nadu Trade Promotion Organisation has published Construction Of Additional Exibhition And Convention Hall, Multilevel Carparking And Utility Building For The Expansion Of Chennai Trade Centre, Nandambakkam, Mount Poonamalle. Submission Date for this Tender is 03-12-2019. Building Work Tenders in Nandambakkam, Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.
Name of Work:Construction of Additional Exibhition and Convention Hall, Multilevel Carparking and Utility Building for the Expansion of Chennai Trade Centre, Nandambakkam, Mount Poonamalle Road, Chennai - 600 089 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | MAIN BUILDING | BI01010001010000000000000515BI0100001112 | ||
2 | 1.001 | STRUCTURAL WORKS | |||
3 | 1.002 | FOUNDATION PILE | |||
4 | 1.003 | Charges Towards Mobilization & Demobilization of Rotary type Mait HR 180 / equivalent or Higher capacity Hydraulic rigs shall be mobilized with necessary Equipments. | 3 | Nos | |
5 | 1.004 | \n650mm dia Pile Boring:- \nProviding and Installation bored Cast-in-situ reinforced cement concrete Piles of Grade M-30 Ready Mix Concrete having Minimum Cement Content as per IS 456 with necessary admixtures and plasticiser. Piles are end bearing piles of basic length 5.00 Mtr and additionally anchoring in the rock at bottom by 1.5 times dia of the piles in all types of soil with driving 8mm thickness of temporary steel casing with necessary stiffener bands and sharp edge at bottom; casing shall be provided up to non-collapsible strata from the existing ground level (as per Site condition), boring in over-burden and through all type of strata encountered up to the founding level as described in the drawing, socketing in approved strata, using bentonite slurry, including disposal of all bored materials etc.complete as per drawings and specifications. Rate is inclusive of Pile boring in all types of soil, Bentonite flushing, Cage lowering, Supplying and installation of concrete, Pile head chipping, Plant installation, collection of sub soil samples in each pile, etc., ( Length of pile for payment shall be measured from toe of pile to bottom of pile cap, Reinforcement will be paid separately ) In all types of soil such as Brownish Clay, Sandy Silty, Clayey sand, Very Dense Completely Weathered Rock etc., (Kindly refer soil report) \n | 7249 | Mtr | |
6 | 1.005 | \nInitial Load Test - 2.5 Times of the Safe load (650mm dia Pile- 200 MT):- \nVertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer incharge. \n | 3 | Nos | |
7 | 1.006 | Routine Load Test - 1.5 Times of the Safe load ( 650mm dia Pile - 200 MT) | 6 | Nos | |
8 | 1.007 | \n650mm dia Pile Integrity testing:-\nPile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.\n | 705 | Nos | |
9 | 1.008 | \nPile Reinforcement Works:-\nProviding, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as Pile, walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786. ( Note: Helical Reinforcement should be welded as per IS Standards, Authorized Laps, Spacer Bars and Chairs shall be measured for payment. )\n | 210769 | Kgs | |
10 | 1.009 | CEMENT CONCRETE WORKS:- | |||
11 | 1.01 | \nProviding, machine mixing and laying Plain cement concrete (PCC) 1:4:8 ( 1 Cement : 4 sand : 8 graded stone aggregate 20mm nominal size ) of required thickness for foundation, rafts, plinth beams, levelling course and all locations, etc. (minimum cementitious content shall be as specified in the IS Code and as approved); including compacting, curing, required shuttering and its removal, dewatering where required and vibrating, cleaning, preparing surfaces, junctions, etc.; complete at all depths and leads as per the drawing and to entire satisfaction of the PMC/Employer. (Note: Using M - sand)\n | |||
12 | 1.011 | Pilecap & Tie beam | 199 | Cum | |
13 | 1.012 | Below Grade slab ( Front Lobby & Rearside services ) | 534 | Cum | |
14 | 1.013 | REINFORCED CONCRETE WORKS:- | |||
15 | 1.014 | \nProviding, transporting, pumping and laying batched design mixed, controlled concrete of different grade ( as specified in the Structural drawings ) conforming to ( IS 456 ) with minimum cement content and maximum water cement ratio as per IS or as specified by Structural Consultant including using approved quality admixtures and placed either with pump / manual / lift for following grades of concrete including compacting, vibrating, curing and protecting etc., complete at all lead, lift & heights as per the drawing and to entire satisfaction of the PMC / Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. ( No separate payment will be made by the Employer towards wastage ). ( Note: Using M - sand )\n | |||
16 | 1.015 | M30 Grade Concrete - ( Sl. No 1.016 to 1.020 ) | |||
17 | 1.016 | Pilecap | 2029 | Cum | |
18 | 1.017 | Tie beam | 486 | Cum | |
19 | 1.018 | Grade slab | 567 | Cum | |
20 | 1.019 | Rainwater sump | 552 | Cum | |
21 | 1.02 | Pedastals | 148 | Cum | |
22 | 1.021 | M35 Grade Concrete - ( Sl. No 1.022 to 1.049 ) | |||
23 | 1.022 | Shear walls | |||
24 | 1.023 | Ground floor | 799 | Cum | |
25 | 1.024 | Ground floor Mezzanine | 163 | Cum | |
26 | 1.025 | First floor | 163 | Cum | |
27 | 1.026 | First floor Mezzanine | 163 | Cum | |
28 | 1.027 | Terrace floor | 41 | Cum | |
29 | 1.028 | Columns | |||
30 | 1.029 | Ground floor | 333 | Cum | |
31 | 1.03 | Ground floor Mezzanine | 278 | Cum | |
32 | 1.031 | First floor | 228 | Cum | |
33 | 1.032 | First floor Mezzanine | 211 | Cum | |
34 | 1.033 | Terrace floor | 43 | Cum | |
35 | 1.034 | Floor Slabs | |||
36 | 1.035 | Ground floor Mezzanine | 1067 | Cum | |
37 | 1.036 | First floor | 2746 | Cum | |
38 | 1.037 | First floor Mezzanine | 693 | Cum | |
39 | 1.038 | Terrace floor | 693 | Cum | |
40 | 1.039 | Floor Beams | |||
41 | 1.04 | Ground floor Mezzanine | 498 | Cum | |
42 | 1.041 | First floor | 435 | Cum | |
43 | 1.042 | First floor Mezzanine | 278 | Cum | |
44 | 1.043 | Terrace floor | 278 | Cum | |
45 | 1.044 | Staircase | |||
46 | 1.045 | Ground floor | 117 | Cum | |
47 | 1.046 | Ground floor Mezzanine | 104 | Cum | |
48 | 1.047 | First floor | 96 | Cum | |
49 | 1.048 | First floor Mezzanine | 51 | Cum | |
50 | 1.049 | Rainwater gutter walls at Terrace floor | 216 | Cum | |
51 | 1.05 | FORMWORK:- | |||
52 | 1.051 | \nProviding, fabricating, erecting form work and deshuttering at all levels and places wherever needed / specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles.\n | |||
53 | 1.052 | Pilecap | 2752 | Sqm | |
54 | 1.053 | Tie Beam | 2632 | Sqm | |
55 | 1.054 | Shear wall at all levels | 10094 | Sqm | |
56 | 1.055 | Columns at all levels | 7419 | Sqm | |
57 | 1.056 | Floor Slab at all levels | 13567 | Sqm | |
58 | 1.057 | Floor Beam at all levels | 8789 | Sqm | |
59 | 1.058 | Staircase at all levels | 2241 | Sqm | |
60 | 1.059 | Rainwater gutter walls | 2874 | Sqm | |
61 | 1.06 | REINFORCEMENT WORKS:- | |||
62 | 1.061 | \nProviding, transporting to site, storing, de-coiling ( if required ), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete ( of same grade of concrete ) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786. ( Note:- Authorized Laps, Spacer Bars and Chairs shall be measured for payment )\n | 2.04828e+06 | Kgs | |
63 | 1.062 | STRUCTURAL STEEL WORKS | |||
64 | 1.063 | \na) Primary Sections with Miniumum 5mm Thick plate Providing, fabricating, painting, transporting & erection in position of steel structure using parallel Built-up sections of structural steel plate of thickness as per design conforming to IS 2062 Grade E350 BR, and as per latest IS code with HSFG bolts 8.8 Grade. Surface preparation with SA2.5 blasting & Epoxy primer/paint with minimum 120 Microns DFT of approved make (Factory applied). This items also include preparation of shop drawings, erection drawings, scaffolding & staging, all labour, tools & required equipment’s etc. Required to complete the job as per drawing & specification. This items also includes all tests on material and weld fabricated parts as per specification.\nb) Secondary Sections:- Providing, fabricating, painting, transporting & erection in position of steel structure using Rolled sections of thickness as per design conforming to IS 2062 Grade E250 like angles, pipes, bracings etc. as per latest IS codes with HSFG bolts. Surface preparation with SA2.5 blasting & Epoxy primer/paint with minimum 120 Microns DFT of approved make. This items also include preparation of shop drawings, erection drawings, scaffolding & staging, all labour, tools & required equipment’s etc. required to complete the job as per drawing & specification. This items also includes all tests on material and fabricated parts as per specification.\nc) Cold formed sections with Minimum 1.75mm Thick sheet Providing, fabricating, transporting & erection in position of steel structure using Cold Formed sections of thickness as per design conforming to IS 2062 Grade E350 BR. as per latest IS codes with HSFG bolts. This items also include preparation of shop drawings, erection drawings, scaffolding & staging, all labour, tools & required equipment’s etc. required to complete the job as per drawing & specification. This items also includes all test on material and fabricated parts as per specification.\nd) Anchor Bolts:- Providing, fabricating, transporting of Anchor bolts Gr 4.6 with IS : 2062 Gr A standard & Minimum Yield strength of bolt shall be 250 MPa \ne) Connection Bolts:- Providing, fabricating, transporting of Connection bolt Gr 8.8 with ASTM A 325 M standard & minimum yield strength of bolt shall be 345 MPa\nf) Anchor bolts and connection bolts shall be measured under relevant items of structural steel work in kilograms. \nHowever touchup / patch Painting if necessary will permitted at site.\n | |||
65 | 1.064 | Columns | 852012 | Kgs | |
66 | 1.065 | Main Truss | 251988 | Kgs | |
67 | 1.066 | Rafter | 376871 | Kgs | |
68 | 1.067 | Floor Beams | 1.84538e+06 | Kgs | |
69 | 1.068 | Pipe Bracings | 106167 | Kgs | |
70 | 1.069 | UC Bracings | 63157 | Kgs | |
71 | 1.07 | \nDecking Sheet - 1mm thick: Providing and fixing Galvanized MS troughed metal sheet decking plate ( Galvanized to grade 275 minimum as per IS :277) for cast-in-situ RCC slab as per specification. Total coated thickness (TCT) of deck sheet shall be 1mm of trough depth of 52mm and minimum yield strength of 240 MPa of approved make. ( Note: Methodology of fixing details should be got approved from the Enginneering Consultant / Employer )\n | 18133 | Sqm | |
72 | 1.071 | \n50mm thick PUF Panel - Roofing:- Providing, Transporting & erection of Pre fabricated & colour coated Galvalume 50mm thick PUF Panel (40 + 2Kgs/Cum) layed in Roofing by Tongue and Groove system locking, with Ribs, With Camlock and Nylon guard film on Both side.\nSheet Thickness: CCGL 0.47mm TCT; AZ 150 GSM/ 0.40mm TCT\nFire Resistance: Class B3 as per DIN 4102\nCompressive Strength: >120 kpa\nTensile Strength: >150 kpa\nShear Strength: >100 kpa\nThermal Conductivity (‘k’ Value): 0.019 w/m deg C\nClosed cells: >90%\nWater Absorption by volume (after 24 hrs): 1%\n | 9815 | Sqm | |
73 | 1.072 | JOINTLESS STEEL FIBRE REINFORCED CEMENT CONCRETE | |||
74 | 1.073 | Separation Membrane:- Providing and Laying of 2 layers 200 Micron thick LDPE sheet over compacted soil. | 10312 | Sqm | |
75 | 1.074 | Supplying and laying of M25 grade concrete as per approved mix design, mixed homogenously and supplied at appropriate workability as per the specification ( Average 150 mm thickness ) ( Note: Rate to be inclusive of tolearance limit for finishing ) | 1599 | Cum | |
76 | 1.075 | Steel Fibre: Providing & mixing Hooked End and Glued Non balling Steel fibres Aspect ratio 65, Length 60mm and dia 0.95mm as per CE Label Mark System 1 ( Steel fibres for structural use ) at Dosage : 25kgs/m3, Dramix 4D 65/60 BG manunfactured by BEKAERT or equivalent | 39975 | Kgs | |
77 | 1.076 | Reinforcement:- Providing and Fixing of 8mm dia @ 150mm c/c on both ways at top including of chairs, covers as per the drawings. | 51560 | Kgs | |
78 | 1.077 | Finishing:- FM3 Levelling, Vibrating by using Laser Screed and Finishing Concrete, removing the surface undulation by Electrical Skim Floater, Special Tools and Final finishing with Ride-On- trowel to get Smooth finish to the requirement of Surface. | 10312 | Sqm | |
79 | 1.078 | Floor Hardener ( AR Class 2 ):- Supplying and laying of Wear resistant topping of 4 - 5 mm by Non metallic floor hardener of Abrasion Class AR 2 as per BS 8204 - Part 2 at the recommended dosage of 10kgs/m2 applied on, wet on wet concrete surface of Rocland make or equivalent ( Colour : Grey ) | 10312 | Sqm | |
80 | 1.079 | Joint Profile:- Supplying and fixing of Signature joint protection with prefabricated galvanised steel joint profile of 150 mm depth of Signature joint manufactured by Permaban UK or equivalent | 183 | Mtr | |
81 | 1.08 | Isolation Joint: Providing Isolation Joint in floor with PU pad of 12 mm thick and Saw cutting the Joint for a width of 12 mm and Depth of 20 mm and filling the gap 12 mm X 20 mm with Polysulphide sealant, backer rod, labours, materials etc., all complete . | 808 | Mtr | |
82 | 1.081 | Column Auxillary Reinforcement:- Providing and fixing of reinforcement around the columns with 5 Nos of 1.20Mtr length 8 mm dia @ 100mm c/c as per the drawing. | 690 | Kgs | |
83 | 1.082 | Polishing & Densifications:- Using Polishing machine with different grit of diamond tools to get Smooth finish and Densifiying the floor with approved chemicals. Surface Hardening ( Concrete Densification ) using Lithium Densifier in uniform quantity ( 6 Sqm Per liter approx.) including preparation of surface by removing dirt, layer of curing compound by wet ( water ) grinding, cleaning with a mechanical scrubber or soft broom to allow maximum penetration of the liquid and get non porous dust free surface etc complete" | 10312 | Sqm | |
84 | 1.083 | \nToilet Waterproofing\nSupplying and installation of two component, Polymer modified waterproof coating Fosroc Brushbond RFX seamless, elastomeric water-proof coating.\na) Surface Preparation:- The cleaning and preparation of the substrate to which Fosroc Brushbond RFX is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Greese, oil and other contaminants which may impair adhesion must be removed prior to the application. Surface shall be maintained in SSD condition before applying waterproof coating.\nb) Coving at Right Angle Junctions:- All the right angle junctions between floor and wall shall be provided with coving of size 75mm x 75mm minimum 15mm thickness in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with Nitobond SBR.\nc) Down Take Pipe Packing:- The pipes to be fixed should be filed in order to provided a proper bond and the same to be alligned by the respective agency. The annular space around the drain pipe shall be packed using Conbextra GP2, a high strength free flow non shrink grout mixed with water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR on the core surface fixing leak free form work as per manufacturer's specification. \nd) Pressure Grouting at Leaking points:-Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg of cement including joints packing using polymer modified mortar. Fixing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification\ne) Waterproof coating:- Providing and applying waterproof coating using Brushbond RFX at 1mm thick in 2 coats at a coverage rate of 12 - 14 sqm per 20.88kg bag with interval period of 6 hours over a substrate with Saturated Surface Dry condition. Termination to be done on wall extending the coating to min.300mm height above the finished floor level and sealed in the termination groove of 20mm wide and 10mm deep flushed with polymer modified mortar as per vendor recommendation. The applied material of Brushbond RFX should have a weight loss of less than 1gm when tested for abrasion resistance according to ASTM-D4060,Tensile strength as per ASTM D638 is 2N/mm² Adhesion to concrete is greater than 1N/mm² and static crack accommodation of 1mm according to ASTM-C836.\n | 2484 | Sqm | |
85 | 1.084 | \nProtective Plastering for the above item:- Fine sand shall be sprinkled while the coating is in tacky condition. Providing and laying plastering of 12mm thickness in CM 1:4 mixed with integral waterproofing compound Conplast WL @ 150ml per bag of cement. System include necessary preparation, curing with water, chemicals used, labour, etc as per specification complete\n | 2484 | Sqm | |
86 | 1.085 | \nRainwater Collection pit Waterproofing \nSupplying and installation of two component, Polymer modified waterproof coating Fosroc Nitocote CM 210 seamless, elastomeric water-proof coating.\na) Surface Preparation:- The cleaning and preparation of the substrate to which Fosroc Nitocote CM 210 is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application. Surface shall be maintained in SSD condition before applying waterproof coating.\nb) Coving at Right Angle Junctions:- All the right angle junctions between floor and wall shall be provided with coving of size 75mm x 75mm minimum 15mm thickness in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with Nitobond SBR.\nc) Down Take Pipe Packing:- The pipes to be fixed should be filed in order to provided a proper bond and the same to be alligned by the respective agency. The annular space around the Rain water pipe shall be packed using Conbextra GP2, a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR on the core surface fixing leak free form work as per manufacturer's specification. \nd) Pressure Grouting at Leaking points:- Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. FIxing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification\ne) Waterproof coating:- Providing and applying Fosroc Nitocote CM210, an elastomeric cementitious coating. System shall consist of two-component polymer modified cementitious coating mixed on site using a slow speed drill fitted with a mixing paddle and then applied to the substrate using a trowel for best results. The product shall be applied in 2 layers to achieve the DFT of 2mm. Coating shall be applied to the entire surface of floor and wall. The cured coating, after immersion, shall be capable of withstanding cracked substrate cyclic movement from 0 - 300 - 0 microns at 15°C for 6,000 cycles without failure. It shall have the capability to resist a positive water pressure of 5 bar and a negative water pressure of 3 bar when tested to European standard CEN/TC 67-67072:2003 part A-7.complete as per manufacturer's specification, approved drawings, as specified and as directed by Engineer, at all levels\n | 7557 | Sqm | |
87 | 1.086 | \nProtective Plastering for the above item:- Fine sand shall be sprinkled while the coating is in tacky condition. Providing and laying plastering of 12mm thickness in CM 1:4 mixed with integral waterproofing compound Conplast WL @ 150ml per bag of cement. System include necessary preparation, curing with water, chemicals used, labour, etc as per specification complete\n | 7557 | Sqm | |
88 | 1.087 | \nARCHITECTURAL WORKS\n | |||
89 | 1.088 | \nMASONRY WORKS\n | |||
90 | 1.089 | \nProviding and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar using 30kgs/cum of masonry all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). \n | |||
91 | 1.09 | Ground Floor | 1051 | Cum | |
92 | 1.091 | Ground floor Mezzanine | 708 | Cum | |
93 | 1.092 | First floor | 919 | Cum | |
94 | 1.093 | First floor Mezzanine | 714 | Cum | |
95 | 1.094 | Terrace floor | 79 | Cum | |
96 | 1.095 | \nExtra rate over & above Solid Masonry wall for providing RCC Binder 80 mm thick with M20 Grade reinforced cement concrete using coarse graded aggregate of 12 mm and downsize, reinforced with 4 Nos of 8 mm dia Fe500 grade steel and 6 mm dia Mild steel stirrups at 200 mm c/c and binders placed at intervals not more than 1000 mm, including cost of reinforcements and tying in position using binding wire made out of 18 gauge GI annealed, form work, scaffolding, all labour, hire and fuel charges for all tools and plants employed and all other incidental charges etc. all complete, as directed, in 150mm thick walls.\n | |||
97 | 1.096 | Ground Floor | 1220 | Mtr | |
98 | 1.097 | Ground floor Mezzanine | 806 | Mtr | |
99 | 1.098 | First floor | 1169 | Mtr | |
100 | 1.099 | First floor Mezzanine | 800 | Mtr | |
101 | 1.1 | \nProviding and applying 10mm thick ceiling plaster including Staircase waist slab in cement mortar mix ratio CM 1:3 (1 cement : 3 River sand), to internal surfaces of concrete work; including hacking concrete surfaces then applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate, preparing grooves, pattas, wattas, rounding of corners, etc. all complete as per architectural drawings, specifications and finished smooth with wooden rundha etc. or as specified; at all leads, depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces, curing, etc. complete as per specification and to the approval of the PMC/Employer.\n | |||
102 | 1.101 | Ground floor | 2218 | Sqm | |
103 | 1.102 | Ground floor Mezzanine | 273 | Sqm | |
104 | 1.103 | First floor | 703 | Sqm | |
105 | 1.104 | First floor Mezzanine | 273 | Sqm | |
106 | 1.105 | \nInternal Plastering:- Providing and applying 15mm thick plaster in cement mortar mix ratio CM 1:4 ( 1 cement : 4 River sand ), to internal surfaces of concrete and masonry work; including raking out joints, hacking concrete surfaces and applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate; also providing and fixing 20 gauge GI chicken mesh @ 150 mm wide to junctions of concrete and masonry, preparing jambs, sills, grooves, bands, wattas, rounding of corners, etc. all complete as per architectural drawings, specifications and finished smooth with wooden rundha etc. or as specified by the PMC/Employer at all leads, depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces, curing, etc. complete as per specification and to the approval of the PMC/Employer. ( Location: Internal wall surfaces and behind wall dado )\n | |||
107 | 1.106 | Ground floor | 13597 | Sqm | |
108 | 1.107 | Ground floor Mezzanine | 10618 | Sqm | |
109 | 1.108 | First floor | 9674 | Sqm | |
110 | 1.109 | First floor Mezzanine | 10618 | Sqm | |
111 | 1.11 | Terrace floor | 1003 | Sqm | |
112 | 1.111 | \nExternal Plastering:- Providing and applying minimum 18mm thick double coat cement sand plaster; first coat to be 12mm thick cement sand mortar of mix ratio CM 1:5 (1 cement : 5 River sand) including adding 2% by weight of cement approved waterproofing compound of approved manufacturer, second coat to be 6mm thick in cement sand mortar of mix ratio CM 1:3 ( 1 cement : 3 River sand ), finished sand face or as required to receive specified architectural external finish to correct line, plumb and level to external faces of walls, sofits/ceiling if any, including hacking concrete surfaces then applying chemical adhesive coating and a scratch/dash coat as a positive bond, curing the same, racking out junctions of masonry and concrete, then pointing and grouting using non-shrinking compound, joints grouted by pressing square crushed stone, further providing 150mm wide 20 gauge GI chicken mesh at junctions of concrete and masonry work, doing independent double legged scaffolding etc.\nItem also include necessary scafolding, plastering to window sills, RCC cornices, making wattas, drip-moulds, bands, grooves etc., doing curing, cleaning, etc. all complete to the approval of the PMC/Employer. ( To External Surfaces )\n | 13921 | Sqm | |
113 | 1.112 | \nMarble Flooring:- Supplying and laying 18mm ( + )1mm thick approved Italian marble flooring of specified size and pattern laid over 20mm thick Cement sand mortar ( M-Sand )1:4 bed with a layer of White cement slurry topping over mortar. Marble floor joints shall be filled using epoxy based grouting material of matching colour including all other necessary related works, cleaning, all leads & lifts, etc complete and as specified in the drawings, specifications and as directed by Engineer-in-charge. Rate shall include wastages, necessary coats of polishing to the satisfaction of PMC/Employre and necessary floor protection with 400 micron transparent polythene sheet with 10mm thk POP over lay till hand over. ( Basic price Rs.260/Sft ) Location:- Ground floor & First floor Air-Conditioned Lobby \n | 3418 | Sqm | |
114 | 1.113 | \nGranite Flooring:- Providing and laying 18mm ( + )1mm thick approved machine cut, machine polished Granite stone flooring in pattern and size as detailed in drawing or as directed by the PMC/Employer. Stone to be bedded over minimum 20mm thick cement sand mortar mix ratio 1:6 (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, joints to be cleaned and grouted with matching colour approved quality polymer based readymade grout (Bal or Laticrete or equivalent approved), wastages, curing, cleaning, polishing to required line, level, protecting till handing over etc. all complete at all heights and leads to the satisfaction of the PMC/Employer. (Note: Supplying of Granite should be from Tamil Nadu Mines and Minerals approved Licensed quarry) ( Basic Price Rs.140/Sft ) Location:- Ground floor & First floor Non - Condioned Lobby, Pre-function lobby, Business Centre \n | 4543 | Sqm | |
115 | 1.114 | \nCarpet Flooring:- Providing and laying of Carpet Tile over the specified area with following specification. The floor which recieves the carpet to be thourougly cleaned as per manufacturer's specification. The carpet is to be laid over a bed of manufacturer's approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include Supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns thickness, held together with scotch tape. The laid carpet to be vacuumed after the removal of protective cover/on commissioning. If after the protective layer is removed and stains observed in the carpet because of in adequate protection, the same shall be shampooed and made good to the satisfaction of the project managers. The measurements of carpet will be the actual laid area. ( Basic Price Rs.140/Sft ) Location:- First floor Convention Hall & Conference Hall \n | 5447 | Sqm | |
116 | 1.115 | \nVitrified Tile Flooring:- Providing and laying approved first quality, colour, design and shade Vitrified Tiles 600mm x 600 x 10mm of approved make (conforming to IS 15622, water absorption less than 0.05%) flooring in pattern as detailed in drawing or as directed by the PMC/Employer. Tile to be bedded over minimum 20mm thick cement sand mortar mix ratio 1:6 (1 cement : 6 coarse sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 Kg/Sqm over cleaned surface and spreading neat cement paste using minimum cement about 4.5 Kg/Sqm over cement mortar bed, joints to be cleaned and grouted with matching colour approved quality ploymer based readymade grout, curing, cleaning, to required line, level, protecting till handing over including wastages all complete at all leads, lifts and heights to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.60/Sft ) Location:- Toilets, Disaster Management, Medical centre, AV room, Pantry\n | 7140 | Sqm | |
117 | 1.116 | \nProviding and laying Granolithic flooring (Cement Flooring) of 80mm thick with cement concrete 1:1.5:3 ( 1 cement : 1.5 M- sand : 3 graded stone aggregate ) using 20mm hard broken stone aggregate laid to level or slope in bays not exceeding 3 sqm per panel including providing metal/glass strips to the full depth of the flooring and finishing the top with rubbed, smooth with power trowel, thread lining, curing, including all leads and lifts in all levels etc; complete all as per standard specifications. (The rate is inclusive of necessary planking for panelling wherever necessary as directed by the PMC / Employer) Location:- Electrical room, Furniture storage, Compressor, AHU room, Convention & Conference Halls\n | |||
118 | 1.117 | Ground floor | 1349 | Sqm | |
119 | 1.118 | Ground floor Mezzanine | 3107 | Sqm | |
120 | 1.119 | First floor | 8234 | Sqm | |
121 | 1.12 | First floor Mezzanine | 3092 | Sqm | |
122 | 1.121 | \nProviding and laying 18mm ( + )1mm thick approved machine cut, machine polished Granite stone flooring in Treads & Riser as per drawing or as directed by the PMC/Employer. Treads in one piece or as directed to full length of step to be rounded at front and all exposed edges machine polished. Further treads to have 2 nos of 5mm x 5mm deep grooves on top at front or as detailed in drawing. Treads & Riser to be bedded in cement mortar minimum 20 mm thick mix ratio 1:6 (1 cement : 6 M-sand) including preparing and cleaning surfaces, spreading cement slurry using minimum cement 2 kg/sqm over prepared surface and 4.5 kg/sq m over bedding, joints to be cleaned and grouted with matching colour approved readymade grout, curing, cleaning, polishing (machine/hand polishing again if required by PMC/Employer) all complete at all heights and leads to the approval of the PMC/Employer. (Note: Supplying of Granite should be from Tamil Nadu Mines and Minerals approved Licensed quarry) ( Basic Price Rs.180/Sft ) Location:- Entrance Steps & Fronside Staircase\n | 1148 | Sqm | |
123 | 1.122 | \nProviding and laying 25mm thick machine cut, machine polished approved Kota stone flooring in Treads & Riser pattern and size as detailed in drawing or as directed by the PMC/Employer. Stone to be bedded in 20mm thick cement mortar 1:6 (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, to required line, level; joints to be cleaned and grouted with matching colour approved quality readymade grout, curing, cleaning, polishing, protecting etc. all complete at all heights and leads to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.35/Sft) Location: Service Staircase Tread, Riser & landings)\n | 1141 | Sqm | |
124 | 1.123 | \nProviding and fixing of Aerocon Panels (Exterior Grade) of size 3000 x 600 x 75mm thick installed on 0.8mm thick GI Channels fixed at top and bottom with necessary accessories panels fixed on to it with tongue and groove joint locking and finished with USG Boral jointing compound & tape etc., including trasportation, loading, unloading, leads and lifts at all levels complete., all as per approved drawings. ( Note: Rate is inclusive of one Coat Primer & Wherever Putty Required )\n | 8019 | Sqm | |
125 | 1.124 | \nProviding and fixing of Aerocon Panels (Exterior Grade) of size 3000 x 600 x 50mm thick installed on 0.8mm thick GI Channels fixed at top and bottom with necessary accessories panels fixed on to it with tongue and groove joint locking and finished with USG Boral jointing compound & tape etc., including trasportation, loading, unloading, leads and lifts at all levels complete., all as per approved drawings. ( Note: Rate is inclusive of one Coat Primer & Wherever Putty Required )\n | 2757 | Sqm | |
126 | 1.125 | \nProviding and cladding of Italian marble slab of thickness 20mm ( + 1mm) thick best quality marble of size as per drg. using dry fixing method. Each slab is to be individually supported using 4nos of stainless steel clamps, two each at top and bottom with SS clamp will be of size as per site condition to achieve on overall depth of 40 to 45mm (Including thickness of stone. Each SS clamp will be fixed to the wall using two numbers of MS oxidized non-corrosive expansion anchor fasteners of size 10mm head, 6mm dia, 100mm length for masonry work and 10mm head, 6mm dia, 50mm length for RCC areas. Each marble slab will have two SS clamps at the bottom with the lipping of 12mm height embedded in the groove cut in the marble and the groove depth being 20mm and width being 5mm.The Bottom row of slabs shall be packed with cement mortar additionally. Structural steel support work wherever required shall be measured seperately. ( Basic Price Rs.260/Sft ) Location: Main Lobby Lift, Column and Prefunction lobby\n | 1040 | Sqm | |
127 | 1.126 | \nProviding and fixing 6mm thick Mirror of approved make with 12mm thick marine grade plywood (conforming to IS 710) backing and teakwood beading (anti-termite treated, kiln seasoned) on four sides, including necessary SS (304) studs, beading to be finished with melamine polish in approved shade, etc. complete to entire satisfaction of the PMC/Employer. Location:- Main Lift Lobby\n | 61 | Sqm | |
128 | 1.127 | \nVitrified Tile Cladding:- Providing and fixing approved first quality, colour, design and shade Vitrified Tiles 600mm x 600mm x 10mm of approved make (conforming to IS 15622 and EN 176 and water absorption less than 0.05%) dado to walls/columns, as shown in drawing or as directed by the PMC/Employer. Tile fixed over pre-plastered (12mm thick) masonry / RCC surfaces by using approved compatible adhesive (Bal / Laticrete or equivalent approved) over plastered surface to correct line, level and plumb. Joints are well cleaned and grouted with matching colour polymer based approved quality readymade grout and cured, cleaned, junctions with plaster finished smooth, etc. all complete at all heights and leads to the satisfaction of the PMC/Employer. ( Basic Price Rs.60/Sft ) Location:- Toilets, Pantry\n | 2411 | Sqm | |
129 | 1.128 | \nVitrified Tile Cladding:- Providing and fixing approved first quality, colour, design and shade Vitrified Tiles 600 x 600mm x 10mm of approved make (conforming to IS 15622 and EN 176 and water absorption less than 0.05%) dado to walls/columns, as shown in drawing or as directed by the PMC/Employer. Tile fixed over pre-plastered (12mm thick) masonry / RCC surfaces by using approved compatible adhesive (Bal / Laticrete or equivalent approved) over plastered surface to correct line, level and plumb. Joints are well cleaned and grouted with matching colour polymer based approved quality readymade grout and cured, cleaned, junctions with plaster finished smooth, etc. all complete at all heights and leads to the satisfaction of the PMC/Employer. ( Basic Price Rs.90/Sft ) Location:- Hall Entry at Ground & First floor\n | 3167 | Sqm | |
130 | 1.129 | \nProviding and fixing Toilet cubicle Classsique Floater Cubicles are toilor-made for restrooms. These Cubicles shall have a clear floor concept which shall be very friendly as far as the maintenance is concerned. These cubicles shall be easily install due to their contemporary designs. To enhance the exquisiteness, all doors are 12mm thick and their stainless steel hardware fittings of approved makes. \nColour of Cubicles : As Per the Greenlam Sturdo Shade Card - Suede Finish \nSize of the Cubicles : 1000mm (Width) * 1500mm (Depth)\nDoor Size : 600mm * 1785mm\nDivider Height : 1820mm\nThickness of Compact Laminate : 12mm\nOverall Height of Cubicle : 1995mm (Including Bottom Gap 150 mm)\nAccessories: Standard – Aluminium, Nylon accessories\na) Nylon Adjustable foot\nb) Nylon Thumb Turm Indicator\nc) Nylon Gravity hinges\nd) Nylon Coat Hook\ne) Nylon Door Knob\nf) Aluminum U Channel\ng) Aluminium Door Stopper Channel\nh) Aluminium Top Rail \ni) Screws, Wall Plugs & Noise Tape\n | 126 | Nos | |
131 | 1.13 | \nSTACKABLE PARTITION:- Supplying and fixing of Stackable Partition of approved make System with standard Vertical Panels and 2 Adjustable telescopic Panel. Frames & Tracks are made of clear anodized aluminium. The frame must be cladded either side with 16mm thick quality MDF board panels hung in acoustic isolation from the frame and allowed to vibrate independently of the frame. The face panels must be easily removable. The panels must be filled with Acoustic Material Rockwool of High density 45Kgs / Cum and Damping material fo 4mm 8Kgs/Sqm to achieve acoustic sound insulation of 45DB. Each panel to have top and bottom rubber retractable seal with concave/convex vertical interlocking profiles. Each panels to be suspended (Single suspension) by Counter Rotating roller carriers to allow panel for the suitable stacking. The rollers must be connected to the element via a shock absorbing mechanism. The individual element must be adjustable in height without opening of the ceiling. Rate is inclusive of 1mm thick laminate of VIR/Merino or equivalent as approved shade as directed by Architect. (Note: Contractor should study the structural Beam drawing and should submit the shop drawing. Rate to include Necessary MS Support structures for suspension and Gypsum Baffeling charges for Side covering and 1mm thick laminate as approved by Architect). The item shall be generally executed as detailed in Drg. No. TMA / CTC / GFC / ARCH / A-18A / R0.\n | 1749 | Sqm | |
132 | 1.131 | \nHALL ACOUSTIC:- Providing and Fixing Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by the Architect/ approving engineer, made of a high density fibre board with minimum 725 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.52. The panels shall be mounted on special aluminium splines using clips provided by Manufacturer and approved by the Architect/ Engineer-in-Charge.\nInstall wooden battens of section 50x50mm or as approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks provided by manufacturer over the lowest and second wooden batten at an on-centre distance of 600mm. Install the Skirting of width 50mm or more as required by the Architect/ Engineer-in-Charge and insert the tongue end of the panel in the skirting. Place the inside clip on the groove end of the panel along the Al keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour. Installation to be carried out by approved Vendor Trained Installation team & Installation should be carried out as per manufactuer recommended procedure. Location: Exibhition Hall and Convention hall inner cladding\n | 4172 | Sqm | |
133 | 1.132 | \nSupplying and fixing of 50mm thick glass wool of 16kgs/cum density wrapped in white tissue and placed in the cavity of the Anodized Aluminium frame work and wood works panel for sound absorbtion.\n | 4172 | Sqm | |
134 | 1.133 | \nSupplying and fixing of un anodized Aluminium frame work using 50x25mm of 1.2mm thick Aluminium box section @ 900mm interval vertically and 600mm interval horizontaly.\n | 4172 | Sqm | |
135 | 1.134 | \nSupplying and fixing of Aluminium anodised 'T' Profile in all Horizontal joints matching wall panel colour.\n | 1070 | Mtr | |
136 | 1.135 | \nSupplying and fixing of wooden beading of size 35mm x35mm polished with Mellamine Matt finish matching to the wall panel colour.\n | 2086 | Mtr | |
137 | 1.136 | \nSupplying and fixing of 9mm thick acoustic (Ecopanel) panelling formed and to be fixed using adhesives as per the manufacturer specificaiton of weight 2Kgs/Sqm and composition of 100% PET (60% Recycled) with B1 FR Rating of size 1200mm x 2400mm ( + 2mm) with sound absorption rating 0.84NRC Location: Exhibhition and Conference Hall inner cladding\n | 5433 | Sqm | |
138 | 1.137 | \nProviding and Fixing of Multi cell Polycarbonate Panels 10 mm thick with 3 cells - 4 walls structure over MS Supporting structures. Panel Width shall be 600 mm to ensure best performance for wind uplift.\nPanels having Vertical Standing Seam 15mm at both sides; snap-on Aluminium connector to interlock the panels shall have a grip-lock 2 tooth locking mechanism to ensure maximum uplift capability. Panels shall be fixed on the structure using Aluminum connector. The panels shall be uniform in color with an integral Multi-Cell core. In a cross section, the core shall be constructed of Microcell of max 4.5mm x 4.5mm. Panels shall be manufactured with approved quality assurance as per ISO 9001 & ISO 14001 and manufactures should have successful project reference having minimum 1500 sq mtr in Indian subcontinent at least for 15 years old. Location:- Main lobby front wall and Pre-function lobby cladding\n | 1199 | Sqm | |
139 | 1.138 | \nProviding and fixing 1mm thick laminate panelling using 12mm thick waterproof marine plywood boards of approved make and conforming to IS 3087; fixed on Aluminium framing of size 50mm x 38mm at every 900mm c/c vertically and 600mm c/c horizontally. Aluminium framing to be fixed and anchored to walls at top and bottom using SS anchor fasteners. Pattern of panelling shall be as indicated in drawings with extra bands as required thickness to be provided so as to produce dubbed / raised panel as required all complete as per Architectural drawings and to the entire satisfaction of PMC/Employer. ( Location: Pre-funtion Lobby Cladding )\n | 120 | Sqm | |
140 | 1.139 | \nProviding and fixing 12mm thick Toughened Glass partition Glazing of height 6.50mtr using SS Spider Point fixing system ( DORMA or equivalent ) with . 21.52mm thick Laminated Glass Fins 450mm wide to be provided from ground floor to ceiling to support 6.50mt high glazing. The system to be designed to withstand wind pressure of 1.5kpa. Provision to be made to provide 2400 x 2400mm Door in the glazing system. Total height of the system to be divided in 3 panels of size 2700mm + 1900mm + 1900mm with width of panel upto 1510mm. Bottom glass panel to be supported in U channel grouted in ground floor. The complete glazing to be aligned and levelled. The gaps between two glass to be filled with silicon weather sealant (DC 789 or equivalent).\n | 457 | Sqm | |
141 | 1.14 | \nGypsum Partition at Conference Hall:- Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.\n75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum board conforming to IS:2095: part I\n | 1742 | Sqm | |
142 | 1.141 | \nFALSE CEILING BAFFLE CEILING SYSTEM – 0.7 MM GI PLAIN, WOOD GRAIN FINISH Providing and Fixing Suspended Metal Baffle Ceilings manufactured in Hook-on system (V-P 500) with Rectangular vertical panel blades made out of 0.7mm thick GI in height of 150mm, widths of 50mm, length of 2400mm. General Specifications:Entire system to be designed in accordance with EN 13964 and TAIM e.V. quality guidelines suitable for Green Building Application for exterior applications, with visible Grid, and connected panels with approved on-centre spacing.\nPanel Specifications: The V-P 500 rectangular Hook-On vertical baffle panels to be made of Galvanized Iron (GI), minimum thickness 0.7mm, 120gsm hot dipped galvanization (both sides), and recycled content of 25%. The panel Length to be 2400mm, panel Widths of 50mm, panel Heights of 150mm, with straight vertical edge having hairline visuals with adjoining panel. The panel surface to be powder coated (post coat) to 60-80µ on visible side after mechanical production, low gloss (degree of gloss approx. 20%). Scrubbable, architectural-quality, electrostatically applied polyester powder coat paint applied to entire panel after forming (post coat). Panel coated on both sides for exterior application. The color to be approved Wood Grain finish (Epoxy Polyester for Interior). The panels to be unperforated plain finish, without having any acoustical Inlay. The panels to be Non-accessible, with system height of 42mm+blade height, and would require a plenum height of a minimum 450mm clear space from bare ceiling / rigid structure.\n | |||
143 | 1.142 | \nThe Fire performance to be Material class A2-s1.d0 according to EN 13501-1 for the metal ceiling panel made of Galvanized Iron, with a powder coating on one side (visible side) with or without inlays. Suspension System Specifications: Primary Runners would be GI U-Profile (black) of 30mm(H) x 3746mm(L) x 20mm(W) x 1.5mm(T), roll formed slotted profile. Accessories would include Hanger for vertical baffle (black, GI), U-Profile Splice (GI), Universal Wall Anchor (GI), Plug-in Clip (spring steel), Distance Holder (spring steel), Connector for vertical baffle (GI), Clamping Bracket (GI). Suspension (normal) would be M6 GI threaded rod (2000mm L) / 2.5mm GI hanger wire (2000mm L). Suspension (wind load) would include compression struts (GI), 38mm deep, 16Ga., cold rolled steel C-channels, 2.68mm GI hanger, splay wire (2000mm L).\nInstallation Specifications: Primary runners Installation: U-Profiles (black), spaced at 1200mm, to be suspended from ceiling using clamping brackets and threaded rods OR hanger wires. Hanger wires must be wrapped tightly with 3 full wraps. The Hanger for vertical baffle shall be located and fastened to the U-profile to the matching square slots at the required on-centre spacing, using plug-in clips. If the pitch distance of the Baffles doesn’t fit with the modulation of the U-Profile (steps of 25mm), the Locking Clip needs to be inserted into a long hole, and the hanger position should be fixed by using a pop-rivet or self-drilling screw. The U-profiles to be fastened to two adjacent walls using the wall anchor and bolts. U-Profiles to be at a maximum distance of 450mm (max.) to a perimeter wall or outside edge of a floating module. To join two pieces of continuous U-profiles, a U-Profile splice to be used. Panel Installation: The V-P 500 rectangular Hook-On vertical baffle panels to be slightly opened and hooked on to the Hangers for vertical baffles (in accordance with the shop drawings). Two panels to be joined together using Connector for vertical baffle. Field-cut Panels: Perimeter panels that require field cutting to create openings / voids for services, must be done in accordance with the cutting instructions provided by the manufacturer. All mechanical services to be independently suspended. For an Interval of 200mm C/c of each baffle - Location:- Hall Entrance lobby Non Air conditioned\n | 2690 | Sqm | |
144 | 1.143 | \nProviding and fixing in true horizontal level Open cell GI lay-in ceiling tiles with border panels forming flush-tegular edge of size 600mmx600mmx38mm having Fire Performance CLASS A1 (EN13964). The tile of ‘Global white’ color with cell size 200mm X 200mm shall be laid on white painted XL15mm profile grid system comprising Main runners (3000mm), 1200mm and 600mm cross tees with 15mm white flanges and 32mm web height. The grid should be make with 15mm wide T - section flanges color white having rotary stitching on all T sections i.e. the Main Runner with C3 coupling, 1200 mm & 600 mm Cross Tees with Hardened XL2 Clip having a web height of 38 mm and a load carrying capacity of 7 Kgs/M. The T Sections have a Galvanizing of 90 grams per M2 with pull out strength of 100 Kgs. To comprise main runner spaced at 1200mm centers securely fixed to the structural soffit by approved hangers at 1200mm maximum centre & not more than 150mm from spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from the adjacent wall. 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long cross tees centrally between the 1200 mm cross tees. Perimeter trim wall angles secured to walls at 450 mm maximum centers. Accessories should consists of M6 Anchor Fasteners with Vertical Hangers made of Galvanized steel Galvanized Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.65 mm of 1.8 m length., thickness of 80gsm and a tensile strength of 344-413 MPa Location:- Exhibition Hall\n | 11914 | Sqm | |
145 | 1.144 | \nProviding and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and directionof the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I ( Location: Main Lobby, Convention Hall & Conference Hall )\n | 13939 | Sqm | |
146 | 1.145 | \nProviding and installing suspended ceiling system at all levels with interlocking grid of size 595x595mm ceiling module of size (600x600) consisting of demountable infill units (size 600 x 600 X 0.6 or 0.7mm) having 50mm gap at every 1200mm, gap covered with 82mm wide channel having flanges to hold ceiling panels. The ceiling shall be powder coated (PVDFPPC,80micron) one xposed and unexposed surface with approved colour. in true horizontal level suspended on interlocking metal grid of hot dipped galvanised steel sections consisting of main 'T' runner suitably spaced atjoints to get required length and of size24x38mm made from 0.33mm thick sheet, spaced1200mm centre to centre, and cross "T" of size 24x28mm made out of 0.33mm sheet, 1200mm long spaced between main 'T' at 600mm centre to centre to form a grid of 1200 x 600mm and secondary cross 'T' of length 600mm and size 24x28mm made of 0.33mm thick sheet to be interlocked at middle of the 1200x600mm panel to from grid of size 600x600mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size (24x24X3000mmmade o f0.40mm thick sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval. \nProviding and laying 6mm thick calcium silicate ceiling tiles of plain in the grid including, cutting/making opening for services liked iffusers, grills, lightfittings, fixtures, smokedetectorsetc. wherever required, Main 'T' runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I.adjustable rods with galvanised steel level clips of size 85x30x0.8mm, spaced at 1200mm centre to centre along main 'T', bottom exposed with 24mm of all T-sections shall be pre-painted, for all heights, drawings and as directed by engineer-in-charge. Location:- Toilets, Disaster Management, Medical centre, AV room, Pantry\n | 1753 | Sqm | |
147 | 1.146 | \nSupplying and fixing of 10mm thick Danpolan Multicell Paneling of size 11980mm x 900mm with standard Accessories like PC Connectors, Spacer, screws, end cap, UPD and Tape( Colour:- Clear + PRL LOW E (IR) Location:- Pre-function lobby (Rate is inclusive of Ceiling suspension system )\n | 72 | Sqm | |
148 | 1.147 | \nJOINERIES\n | |||
149 | 1.148 | \nWooden Acoustic Door: \nProviding and fixing approved make Wooden acoustic Main door of Single/Double leaf, 86 mm thick sandwich type composite sound reducing flush door shutter including Hardwood door frame, comprising as per following details:\n(a) Door frame shall be of hard wood of size - 150 mm X 125 mm, including making necessary grooves for fixing of hollow bulb type EDPM gaskets on rebates / Or Corner seal to block noise leakage from gap in between door frame and shutter. The frame shall be properly finished, sanded and polished with 3 or more coats of melamine polish as per\napproved shade, finish and specifications.\n(b) The frame of door shutter shall be made from 24 mm thick hardwood wood stiles at top & bottom rails , Lock rail 100 mm wide and 24 mm thick and three additional strips 50 mm wide and 24 mm thick (minimum)\n(c) The core of door shutter shall be filled with resin bonded Rockwool of a minimum density of 96 kg/cum conforming to IS 8183 and BS 476 Part-II and one sound damping sheet 03 mm thick to increase STC rating of door shutter.\n(d) Face panels shall be of 12 mm thick Commercial ply boards conforming to relevant IS codes on both sides of the core of the shutter.\n(e) The final finish will be 1.0 mm thick laminate /4mm Veneer as per Architect’s choice / approval on both sides . All edges shall be provided with teak wood lipping, margins etc., including melamine polish as per approved specs, finish and shade.\n(f) An Internal Automatic Dropdown Seal of excellent quality of approved make should be provided. This seal should offer resistance to sound up to 45db, air, insects, smoke, daylight; and should be designed for timber (wooden) doors.\n(g) All Supplying of hardware shall be exclusive and fixing of hardware deemed to be included\n(h) Performance :- The design of door will be as per test conduct from CSIR NPL lab , STC Value will be 45 as per IS:9901( Part III)-1981, DIN:52210 Part- VI-1989, ISO:140 (part III) – 1995. Higher STC 56 at 4000hz\nThe Panels filled with Acoustic material Glass wool of 96 Kg/m3 density , 6 MM thick anti donning layer having Thermal Conductivity 0.037 @ 20 C as per EN ISO 8497 (DIN 52613) and 2 mm thick Sound Damping layer MTS 05-303 to achieve higher Sound STC as per site condition.\nDouble Door size - 2400 x 3000mm\n | 48 | Nos | |
150 | 1.149 | \nProviding, making and fixing wooden door frames made out of approved first quality teak wood chemicaly treated, Seasoned, antitermite treated, shaped, grooved, mitered joint arrangement, mouldings, rebates, including use of approved water repellent adhesive, GI screws, pins, etc. all exposed surfaces to be melamine polished in approved colour and shade, surfaces of frame in contact with masonry / concrete surfaces shall be painted with one coat of hot bitumen of approved quality, 3 nos. GI holdfast (split and 225 x 75 x 2 mm thick) on each side of frame well-grouted with cement concrete mix in a ratio of 1:2:4 (1 cement : 2 sand : 4 aggregate), etc. complete to the entire satisfaction of the PMC/Employer.\n | 7 | Cum | |
151 | 1.15 | \nProviding and fixing factory made 35mm thick solid core flush shutter conforming to IS 2202 (Part - I); Shutter shall be manufactured with exterior quality synthetic adhesive forming marine ply surfaces, internally lipped as manufactured by approved vendor. Further shutter shall be finished both side with 1 mm thick laminated in approved shade and design with hot pressed at factory, edges of shutter shall be provided with 6mm thick teakwood beadings using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with melamine polish, etc. as directed by the PMC/Employer. ( Rate is exclusive of hardware Supplying and inclusive of hardware fixing )\n | 201 | Sqm | |
152 | 1.151 | \nABS DOOR / Equivalent\nProviding and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw. The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated. ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm. PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of Stainless steel ball bearing butterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work Design Pre-laminated door\n | 68 | Sqm | |
153 | 1.152 | \nProviding and fixing of frameless glass door using approved Make, fittings of top and bottom patch, corner lock, Floor spring, Handle 450mm long 'H' type, glazed with 12mm thick clear toughened glass with necessary items to finish the job. (Rate is exclusive of hardware Supplying and inclusive of hardware fixing) GDD1 - 2400mm x 3000mm\n | 86.4 | Sqm | |
154 | 1.153 | \nFD120 Fire rated doors - Painted\nProviding and fixing of Hollow metal Insulated fire rated doors as per IS 3614 part-1, for stability, integrity & insulation. Pressed galvanized steel conforming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire or third party certified or equivavelent lab, for maximum rating of 120mins with 30minutes of insulation, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label conforming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent.\nDoor frame shall be single rebate grooved profile of size 125 x 60mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff.\nDoor leaf shall be 46mm thick fully flush double skin door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density insulation material. Intumescent seals 15x2mm to be provided all around the door in addition to the grooved smoke seal. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door All doors and frames shall be finished Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include Supplying and installation of door, inclusive of Hardware fixing and exclusive of hardware Supplying as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer. Application: Staircase Exit / Lobby Entry / Exhibhition Hall Exit / Electrical rooms / Compressor rooms\n | |||
155 | 1.154 | 120Mins Fire Rated Door Double leaf of size : 1500 x 2100 with vision panel (200 x 300)with hardware set # | 44 | Nos | |
156 | 1.155 | 120Mins Fire Rated Door Single leaf of size : 1200 x 2100 with vision panel (200 x 300)with hardware set # | 6 | Nos | |
157 | 1.156 | 120Mins Fire Rated Door Double leaf of size : 1500 x 2100 with vision panel (200 x 300)with hardware set # | 18 | Nos | |
158 | 1.157 | \nSingle skin automated rolling shutter\nProviding and fixing of single skin rolling shutter. Slats shall be made from galvanised steel 0.8mm (22 guage) as per IS 277 of size 109mm of approved make Hormann or approved equivalent Construction of the slats shall be of 0.8mm thick GI sheet forming to the door height, the bottom edge of the door shall be sturdy aluminum profile for curtain reinforcement, Weather-resistant, flexible EPDM tubular seal for prevention and penetration of dirt and rain. The side guides will be 2mm thick single piece GI guide rail for superior strentch, rubber seals to be provided for smooth and noise free movement. The shutter box shall be Welded standard steel pipe with double flange steel shafts supported by enclosed bearings. Box cover shall be minimum 0.8mm thick steel box casing cover and side guides painted in soft grey color. Motor capacity shall be 1hp for size upto 5000mm x 5000mm, and 3hp for sizes above 5000mm x 5000mm. Connecting volt shall be 220Volt 50Hz 1 phase up to 5000mm x 5000mm, and 415V 50Hz 3 phase for bigger sizes. One unit Push Button Switch (Up, Stop, Down), IP 65. Current rating will be 5 Amp for sizes less than 5000mm x 5000mm, 9 Amp for more than 5000mm x 5000mm size. Vendor should Supplying 16A, 3 pin, industrial male socket with 1Mtr cable along with controller Rolling shutter finish shall be Galvanized and painted in RAL 9002 outside and soft grey from inside Minimum head room shall be 700mm to 1000mm based on door sizes, including motor side 200mm and bearing side 150mm. Rate shall include Supplying and installation of Single skin rolling shutter for Size - 2000mm x 2100mm as per the architectural drawing\n | 7 | Nos | |
159 | 1.158 | \nProviding and fixing of double skin Sectional door SPU F42 as per EN Standard Slats Door made of double-skinned, PU-foamed steel sections of 42 mm cross section,100 % CFC-free & made of hot galvanized steel. Door section heights of 625 or 750 mm. Performance characteristics in accordance to EN 13241-1. EN 12424 Resistance to wind: Class 3. EN 12426 Air permeability: Class 2 (without wicket door). EN 13241 Thermal insulation U = 1.0 W/m²K (without wicket door). EN 717-1 Acoustic rating: R= 25 dB (without wicket door). Frame shall be enclosed, moulded angle frame, made of hot galvanised steel with safety track, secured with screws. For application below 3500mm height VU track shall be used and for higher heights H,N type track to be provided. Space of 300mm shall be provided on the motor side and 150mm on the bearing side of the door. The door shall be counter balanced by coated torsion springs, with carrying cables on the side. Safety feature shall include manually operated door using a torsion spring with approved catch safety device and finger trap protection inside and outside as per DIN EN 12604. Sensor controlled safety devices to monitor the bottom edge of the door, instant stoppage and reversing on encountering any obstruction while closing. Complete ready-to-fit shaft operator with cable slack device. Power input (3-phase current: 0.37 kw) with a protection IP rating of 65. Electronic absolute encoder (AWG) for determining the door position shall be provided. Microprocessor control in separate housing with Open-stop-Close membrane push button integrated in housing, miniature lock, adjustable force limit. Self monitoring closing edge safety device (SKS) with optosensors. Connecting cable with CEE male plug in protection category IP44. Emergency hand chain to be provided in case of power failure. Door leaf shall be polyester-primer coated Grey white exterior and interior, based on RAL 9002. Frame and glazing made of anodized aluminium extrusions with a natural finish in accordance with DIN 17611. All further steel parts manufactured from hot galvanized steel Minimum head room shall be N track - 440mm, H track - 700mm and VU track (Door Height + 780) based on door sizes, including motor side 300mm and be aring side 150mm. Rate shall include Supplying and installation of sectional door\n | |||
160 | 1.159 | RS1 - 5000mm x 6000mm | 4 | Nos | |
161 | 1.16 | RS2 - 5000mm x 4000mm | 2 | Nos | |
162 | 1.161 | \nUPVC Window: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work\n | 438 | Sqm | |
163 | 1.162 | \nUPVC Ventilator: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work\n | 57 | Sqm | |
164 | 1.163 | \nSupplying of the following Iron Mongeries items\n | |||
165 | 1.164 | Accessories | |||
166 | 1.165 | Lockwood Tubular Lever on Rose with Escutcheons SSS | 70 | Nos | |
167 | 1.166 | Lockwood Euro Profile Cylinder Escutcheons SSS | 99 | Nos | |
168 | 1.167 | Lockwood 457mm Recessed Timber Flush Bolts SSS | 28 | Nos | |
169 | 1.168 | Lockwood Mortice Universal Flush Bolt Ferrule SC | 68 | Nos | |
170 | 1.169 | Lockwood 450mm Recessed Aluminium Flush Bolts SSS | 108 | Nos | |
171 | 1.17 | Lockwood dia32x1500(C)x1700mm/dia25x45mmS/S | 120 | Nos | |
172 | 1.171 | Lockwood Bottom Door Patch to suit Floor Springs SSS | 30 | Nos | |
173 | 1.172 | Lockwood Top Door Patch to suit 15 mm pivot SSS | 30 | Nos | |
174 | 1.173 | Lockwood Top Patch with 15mm Pivot SSS | 20 | Nos | |
175 | 1.174 | Lockwood Adjustable Top Pivot with Cover | 10 | Nos | |
176 | 1.175 | Lockwood 150mm x 50mm Rectangular Concealed Fix Flush Pull SSS | 81 | Nos | |
177 | 1.176 | Lockwood dia32x1200(C)x1400mm/dia25x45mmS/S | 32 | Nos | |
178 | 1.177 | Floor Spring Wooden Door Accessories, Top Pivot & Bottom Arm | 122 | Nos | |
179 | 1.178 | Lockwood 200mm x 19mm Standard D Pull back to back in SSS | 42 | Nos | |
180 | 1.179 | Lockwood 120mm x 50mm Rectangular Concealed Fix Flush Pull SSS | 24 | Nos | |
181 | 1.18 | Enox Sliding Door Kit Max.Door Panel Weight 90kg | 12 | Nos | |
182 | 1.181 | Enox Aluminium Inodised Single Top track Non drilled size 3600mm | 12 | Nos | |
183 | 1.182 | Rockwood 2660 Door Co-Ordinator in Black Primed Finish | 17 | Nos | |
184 | 1.183 | Cylinders | |||
185 | 1.184 | Lockwood 6 Pin - 30 x 30 Cyl / Thumbturn - 70mm Total Length - MK | 21 | Nos | |
186 | 1.185 | Lockwood 6 Pin - 30 x 30 Double Cylinder - 70mm Total Length - MK | 130 | Nos | |
187 | 1.186 | Lockwood 5 Pin Single Cylinder C4 Profile - 45mm - MK | 71 | Nos | |
188 | 1.187 | Lockwood 6 Pin - 30 x 30 Privacy - 70mm Total Length | 18 | Nos | |
189 | 1.188 | Door Closers | |||
190 | 1.189 | King Surface Mounted Power Adjustable Door Closer STA-01 HO | 18 | Nos | |
191 | 1.19 | Lockwood Surface Mounted Door Closer Power Selectable 2 - 4 (20kg - 80kg) | 179 | Nos | |
192 | 1.191 | King Surface Mounted Power Adjustable Door Closer | 7 | Nos | |
193 | 1.192 | Exit Devices and Outside Trims | |||
194 | 1.193 | Lockwood Rimlatch Type Panic Exit Device - one point steel with power coating | 71 | Nos | |
195 | 1.194 | Lockwood Vertical Rod Type Panic Exit Device - two point - steel with power coating | 17 | Nos | |
196 | 1.195 | Lockwood Panic Exit Device Outside Access Device (Lever - No Cylinder) | 71 | Nos | |
197 | 1.196 | Lockwood Panic Exit Double Door Strike | 35 | Nos | |
198 | 1.197 | Floor Springs | |||
199 | 1.198 | EN SIZE 3-6 300 Kg.((machinewith cover plate & spindle)(AC360+AC269) | 100 | Nos | |
200 | 1.199 | EN SIZE 2-4 (machinewith cover plate & spindle)(AC360+AC534) | 22 | Nos | |
201 | 1.2 | EN SIZE 2-4 (machinewith cover plate & spindle) | 30 | Nos | |
202 | 1.201 | Hinges | |||
203 | 1.202 | Lockwood 4.0 X 3.0 X 3.0- 2 Ball Bearing Button Tipped SSS 304 with Wooden Screws | 462 | Nos | |
204 | 1.203 | Lockwood 4.0 X 3.0 X 3.0- 2 Ball Bearing Button Tipped SSS 304 with Metal Screws | 537 | Nos | |
205 | 1.204 | Locks | |||
206 | 1.205 | Lockwood Euro Mortice Lock 60mm Backset - Entrance SSS | 70 | Nos | |
207 | 1.206 | Lockwood Euro Mortice Lock 60mm Backset - Deadlock SSS | 87 | Nos | |
208 | 1.207 | Lockwood Corner Lock suits Euro Profile Cylinder SSS | 30 | Nos | |
209 | 1.208 | Lockwood/ ASSA ABLOY Hex Key Security Door Bolt SC | 81 | Nos | |
210 | 1.209 | Lockwood Euro Mortice Sliding Door Lockset No Funiture SSS | 12 | Nos | |
211 | 1.21 | Keying | |||
212 | 1.211 | Grand Master Keys - Grid Layout will be issued at the time of issue of LOA along with GFC drawing before commencement of work. | 5 | Nos | |
213 | 1.212 | Master Keys - Grid Layout will be issued at the time of issue of LOA along with GFC drawing before commencement of work. | 30 | Nos | |
214 | 1.213 | Blank Keys | 50 | Nos | |
215 | 1.214 | \nSupplyinging, Fabrication and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete ( Location: Main Staircase ) Refer Drawing Nos: TMA / CTC / GFC / ARCH / A - 22A, B&C / R0\n | 6040 | Kgs | |
216 | 1.215 | \nProviding, fabricating and fixing M.S. railing work as per drawing out of square bars / class ‘C’ pipes / tees / angles / flats / I sections / channels etc. including providing and fixing GI hold fast as necessary to the of RCC members / brick work, electric welding the joints and grinding smooth the welded joints to give one piece appearance including taking site measurements and preparing shop drawing, getting approval of shop drawing prior to fabrication from the PMC/Employ er, assembly finish with two coats of zinc phosphate primer and two coats of approved make and shade epoxy paint all complete to entire satisfaction of the PMC/Employer. ( Location: Rear Staircase )\n | 4932 | Kgs | |
217 | 1.216 | \nProviding and fixing of 13.52mm Thick ( 6mm + 1.52Pvb + 6mm ) Clear Laminated Toughned Glass Handrail using SS Leg with necessary screws, anchor fasteners with Top 50mm Round Handrail with End Cap with necessary hardware's Refer Drawing No: TMA / CTC / GFC / ARCH / A19-AR0\n | 70 | Mtr | |
218 | 1.217 | Providing and fixing signages as per Drg. No. TMA / CTC / GFC / ARCH - A10 R0 & A10A R0 as directed by the Engineer in-charge | |||
219 | 1.218 | ST 03 - External Signage with Sheet Metal with LED Lights | 1 | Nos | |
220 | 1.219 | ST 04 - Internal Signage Hall ( Nos & Text ) | 6 | Nos | |
221 | 1.22 | ST 05 - Lobby Entry ( Nos & Text ) | 6 | Nos | |
222 | 1.221 | ST 06 - Internal Welcome Sign | 1 | Nos | |
223 | 1.222 | ST 07 - Internal Toilet | 7 | Nos | |
224 | 1.223 | ST 08 - Internal Conference Hall ( Nos & Text ) | 10 | Nos | |
225 | 1.224 | ST 09 - Internal Conference Hall ( Double Text & Double Nos ) | 4 | Nos | |
226 | 1.225 | \nCEILING PAINT:- Providing and applying oil bound distemper of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels. (Rate is inclusive of Scrapping the existing RCC Surface and finishing joints smoothly with putty).\n | 13312 | Sqm | |
227 | 1.226 | \nINTERNAL EMULSION PAINT:- Providing and applying Acrylic emulsion paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); over 2 coats of suitable 1mm thick putty of approved manufacturer including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels.\n | 43098 | Sqm | |
228 | 1.227 | \nEXTERNAL PAINT:- Providing and applying Exterior Emulsion Paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor) of newly plastered wall surface with ready mixed paint of first class quality and approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., required scaffolding, leads and lifts at all levels.\n | 13921 | Sqm | |
229 | 1.228 | \nProviding and fixing Structural glazing (hybrid-semi unitised system) using 15microns electro colour anodised main frame comprising of mullions, transoms, head and cill section, etc) of size 100x55x2mm approximate or equivalent designed to withstand wind pressure upto 150km/hr fixed to RCC slabs using necessary Aluminium / GI angle cleats for slots for adjusting plumb fixed to the RCC/steel member with suitable fasteners, the main frames verticals to span unsupported length of maximum 3m to 4m. The glazed panel is to be made using suitable subframe / glazing section on which galss of approved make, all as per architectural drawing is to be fixed using a combination of double side cross linked polythene spacer tape and structural sealent (GE ultraglaze SSG 4000 or Dow corning 995). The glazed panels after suitable curing in dust free environment is to be fixed on to the main frame from the exterior ( to enable replacement of glass in future) The grooves (12 to 16mm) to be closed with weather grade silicon sealent / EPDM gaskets. The whole system is to be ensured that corrision resistant hardware is used. It should be totally weather proof and permit necessary thermal expansion and contraction and should be able to withstand specified wind loads. The rate should include cost of filler between the floors to have air tight systems. The design should ensure that no Aluminium frame is seen from outside all complete as directed\n | 2527 | Sqm | |
230 | 1.229 | Single glass: Using Single Glass 6mm thick ST 136 Reflective HS Glass | 2527 | Sqm | |
231 | 1.23 | \nTop Hung Window: Extra rate over & aboe the #item no.1 window item for designing, providing and fixing hardwares for top hung open able outward shutter having Heavy duty point lock with required points based on the window panel size and handle of mccoy make, SS friction hinges of mccoy make or approved equivalent make and as per particular specfication. Rate shall exclude cost for supplying and fixing of galzz and main frame, but include cost of hardwares and sub frame for shutter. System to be designed to with stand design wind pressure and other load parameters specified.\n | 22 | Sqm | |
232 | 1.231 | \nProviding and cladding of Granite Cladding of thickness 20mm ( + 1mm) thick best quality granite of size as per drg. using dry fixing method. Each slab is to be individually supported using 4nos of stainless steel clamps, two each at top and bottom with SS clamp will be of size as per site condition to achieve on overall depth of 40 to 45mm (Including thickness of stone. Each SS clamp will be fixed to the wall using two numbers of MS oxidized non-corrosive expansion anchor fasteners of size 10mm head, 6mm dia, 100mm length for masonry work and 10mm head, 6mm dia, 50mm length for RCC areas. Each marble slab will have two SS clamps at the bottom with the lipping of 12mm height embedded in the groove cut in the marble and the groove depth being 20mm and width being 5mm.The Bottom row of slabs shall be packed with cement mortar additionally. ( Basic Price Rs.260/Sft )\n | 304 | Sqm | |
233 | 1.232 | \nProviding and Fixing of GRC - Glass Reinforced Cement Concrete elements Screens in approved size, pattern, design shade and thickness of 15mm to 20mm thick as per drawing No:- TMA / CTC / GFC / ARCH / A-17A / R0. The GRC elements shall be made as follow as:-\na) 53 Grade White Portland Cement - J.K/Brila/RKC\nb) The Silica Sand [1.2mm Size Passing Through 150micron Sieve]\nc) Alkali Resistant Roving Fibre from Nippon (ARG-Fibre)\nd) Acyralic Polimer e) Mould Made by FRP/GRP\nTest Reports: Flexural strength Test should be carried out at approved Laboratary by Engineering consultant and to be submitted to the Employer\nThe GRC Screen Flexural strength average L.O.P shall be above or equivalent to 6N/mm2 & M.O.P should be above or equivalent to 15 N/mm2 for tests done on 28 days cured samples.\nManufacturing Process: a) Using Spray Technology Fixing details:\nb) Using Hilti anchor fastners, 125mm depth, 10mm dia thickness.\nStructural steel work supports wherever required shall be measured seperatley.\n | |||
234 | 1.233 | Supplying and Installation of GRC Column as per drawing No:- TMA / CTC / GFC / ARCH / A-17A / R0. | 2030 | Sqm | |
235 | 1.234 | Supplying and Installation of GRP / FRP Mural as per drawing No:- TMA / CTC / GFC / ARCH / A-17A / R0. | 296 | Sqm | |
236 | 1.235 | \nExternal Works:- Filling including backfilling with approved good quality earth brought under item 1.236 in plinths, area leveling etc. in layers each not exceeding 200mm in depth, breaking clods, watering, compacting each layer with vibratory compactor and at inaccessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content; dressing up embankments; if required, bailing/pumping out of water to keep site dry while back filling complete as per direction and entire satisfaction of the PMC / Employer. \n | 55365 | Cum | |
237 | 1.236 | Coveyance Charges towards including loading & unloading for the above item as per the approved source by the Employer within 10 to 20 Kms in radius | 55365 | Cum | |
238 | 1.237 | UTILITY BUILDING | |||
239 | 1.238 | STRUCTURAL WORKS | |||
240 | 1.239 | \nExcavation in all kinds of soil, wet or dry (such as clay, Silty Clay, Sandy clay with Medium/High Plasticity and Soft disintegrated rock etc.,) in loose and slushy condition, including demolition of any existing concrete portion with suitable mechanical excavators like Poclain, JCB etc., and manually wherever required, to the required level for foundations, trenches, rafts, plinths, area levelling, etc., to required depth from existing ground level including disposing off surplus excavated material within the site and levelling as per directed by the PMC/Employer if required disposal outside the campus at location designated by Employer. \nCovering the carting/loaded vehicle with plastic / tarpauline so as to avoid fall and spread of any excavated material on road, cleaning vehicle tyres before moving out of site etc complete, maintaining all the related records, bailing/pumping out water to keep the site dry at all times until completion of backfilling; making temporary stepping / sloping, shoring with planking, strutting, sectioning, trimming, dressing of sides, levelling or grading, cleaning, removing and excavating loose pockets and consolidating them by backfilling as directed etc., all complete to all depths, to the satisfaction of the PMC/Employer. All pits shall be properly barricaded at any point of time.\n | |||
241 | 1.24 | All kind of Soil - (Upto 1.50Mtr depth from EGL) | 2672 | Cum | |
242 | 1.241 | All kind of Soil - (1.50Mtr to 3.00Mtr Depth) | 1336 | Cum | |
243 | 1.242 | All kind of Soil - (3.00Mtr to 4.50Mtr Depth) | 1336 | Cum | |
244 | 1.243 | All kind of Soil - (4.50Mtr to 6.00Mtr Depth) | 1336 | Cum | |
245 | 1.244 | All kind of Soil - (6.00Mtr to 7.50Mtr Depth) | 1336 | Cum | |
246 | 1.245 | All kind of Soil - (7.50Mtr to 9.00Mtr Depth) | 790 | Cum | |
247 | 1.246 | \nFilling including backfilling with approved good quality earth in plinths, area leveling etc. in layers each not exceeding 200mm in depth, breaking clods, watering, compacting each layer with vibratory compactor and at inaccessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content; dressing up embankments; if required, bailing/pumping out of water to keep site dry while back filling; costs includes transportation of all materials, labour, machinery etc. complete as per direction and entire satisfaction of the PMC/Employer.\n | 1659 | Cum | |
248 | 1.247 | CEMENT CONCRETE WORKS:- | |||
249 | 1.248 | \nProviding, machine mixing and laying Plain cement concrete (PCC) 1:4:8 ( 1 Cement : 4 sand : 8 graded stone aggregate 20mm nominal size ) of required thickness for foundation, rafts, plinth beams, levelling course and all locations, etc. (minimum cementitious content shall be as specified in the IS Code and as approved); including compacting, curing, required shuttering and its removal, dewatering where required and vibrating, cleaning, preparing surfaces, junctions, etc.; complete at all depths and leads as per the drawing and to entire satisfaction of the PMC/Employer. (Note: Using M - sand)\n | |||
250 | 1.249 | Below Raft | 123 | Cum | |
251 | 1.25 | REINFORCED CONCRETE WORKS:- | |||
252 | 1.251 | \nProviding, transporting, pumping and laying batched design mixed, controlled concrete of different grade (as specified in the Structural drawings) conforming to (IS 456) with minimum cement content and maximum water cement ratio as per IS or as specified by Structural Consultant including using approved quality admixtures and placed either with pump / manual / lift for following grades of concrete including compacting, vibrating, curing and protecting etc., complete at all lead, lift & heights as per the drawing and to entire satisfaction of the PMC / Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. ( No separate payment will be made by the Employer towards wastage ). ( Note: Using M - sand )\n | |||
253 | 1.252 | M30 Grade Concrete | |||
254 | 1.253 | Raft | 1086 | Cum | |
255 | 1.254 | M35 Grade Concrete - ( Sl. No 1.255 to 1.276 ) | |||
256 | 1.255 | Shear walls | 795 | Cum | |
257 | 1.256 | Columns | |||
258 | 1.257 | Basement floor | 59 | Cum | |
259 | 1.258 | Ground floor | 121 | Cum | |
260 | 1.259 | First floor | 87 | Cum | |
261 | 1.26 | Terrace floor | 26 | Cum | |
262 | 1.261 | Post Tensioning Floor Slabs | |||
263 | 1.262 | Ground floor | 174 | Cum | |
264 | 1.263 | First floor | 158 | Cum | |
265 | 1.264 | Terrace floor | 158 | Cum | |
266 | 1.265 | Post Tensioning Floor Beams | |||
267 | 1.266 | Ground floor | 106 | Cum | |
268 | 1.267 | First floor | 106 | Cum | |
269 | 1.268 | Terrace floor | 106 | Cum | |
270 | 1.269 | Non Post Tensioning Floor Beams | |||
271 | 1.27 | Ground floor | 38 | Cum | |
272 | 1.271 | First floor | 50 | Cum | |
273 | 1.272 | Terrace floor | 50 | Cum | |
274 | 1.273 | Staircase | |||
275 | 1.274 | Basement Floor | 11 | Cum | |
276 | 1.275 | Ground floor | 11 | Cum | |
277 | 1.276 | First floor | 11 | Cum | |
278 | 1.277 | FORMWORK:- | |||
279 | 1.278 | \nProviding, fabricating, erecting form work and deshuttering at all levels and places wherever needed/specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles. \n | |||
280 | 1.279 | Raft | 131 | Sqm | |
281 | 1.28 | Shear wall at all levels | 2936 | Sqm | |
282 | 1.281 | Columns at all levels | 1372 | Sqm | |
283 | 1.282 | PT Slabs at all levels | 2435 | Sqm | |
284 | 1.283 | PT Beams at all levels | 764 | Sqm | |
285 | 1.284 | Non PT Beams at all levels | 686 | Sqm | |
286 | 1.285 | Staircase at all levels | 193 | Sqm | |
287 | 1.286 | REINFORCEMENT WORKS:- | |||
288 | 1.287 | \nProviding, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786. ( Note:- Authorized Laps, Spacer Bars and Chairs shall be measured for payment )\n | 495428 | Kgs | |
289 | 1.288 | POST TENSIONING WORKS:- | |||
290 | 1.289 | \nDesign and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, Supplyinging, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including Supplying of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the PMC / Employer. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Engineer-in-charge \nSupplying & execution of post tensioning work shall be carried out by approved specialized agency, with their own design, equipment, accessories & skilled manpower for satisfactory completion of work as per approved drawings. The contractor shall have minimum 5 years experienced technical staff for proper monitoring, ensuring & certifying the correctness of entire prestressing operations. Prestressing work shall be duly tabulated and report shall be submitted. Item also to include the required scaffolding etc. including marking the PT strand path locations for easy identification etc. all complete to the entire satisfaction of PMC / Employer. Refer Structural Drawing Nos:- 1920002-CTC-SUBSTATION-12 / 13 & 14\n | 15 | MT | |
291 | 1.29 | \nRaft Slab Waterproofing:- Supplying and installation of Pre applied Pressure sensitive based HDPE membrane for Raft slab waterproofing\ni. All PCC surface should be free from cavities and projecting nibs. Concrete shall be fairly smooth finished, dry and free from frost, surface laitance and contamination. Surface shall be thoroughly washed with water jet to make the surface dust free. Standing water must be removed to prevent contamination of overlaps and subsequent compromise of waterproof properties.\nii) Providing and laying FOSROC HDPE-P membrane 1.2mm thick over the PCC area.The system should be fully bonded to cast in situ RCC under pressure sensitive property including overlapping of the membrane at corners & laps 75mm along selvedge adhesive and end laps, various tie-ins using double sided adhesive tapes - Fosroc Membrane HDPE Sealaed Tape of 100mm wide. Longitudinal joints, Intermediate, repairing and accidental joints shall be showeled and provided with sanded tapes, complete as per the vendors specification. \niii) All vertical surfaces on pile caps shall be fixed to the internal face of the shuttering sheet fixed with aid of spot bonding or in support with cover block as per manufacturer specification \niv) Termination of the membrane shall be done by extending the membrane to the thickness of the raft concrete by sticking the membrane to the form work using sealed tapes.\nv) Intersection point of raft and retaining slab waterproofing to be provided with HDPE sealed tape which is over laid with Retaining wall waterproofing as per manufacturer specification. \nvi) Fosroc Membrane HDPE - P doesn't demand any protection layer. Hence main reinforcement shall be carried directly upon the waterproofing membrane The system shall be able to withstand all site conditions including flooding, slush formation, temperature variation, alternate heat and cold variations in a day etc. complete and the bonding system shall exhibit complete properties during and post concreting works. The membrane shall be capable of UV exposure without additional protection for a maximum of 56 days prior to concrete pouring. Cost to include necessary protections during construction and mechanical anchorages as required. The termination of the system shall be able to receive another type of waterproofing with necessary junction details compatible with all other systems available in the market.\nThe pressure sensitive HDPE membrane shall have punctureresistance of > 950 N (as per ASTM E 154), hydrostatic head resistance not less than 70m head of water (ASTM D 751), unaffected thermal flexibility < 25°C no crack, elongation min 400%, Tensile strength 27 Mpa (ASTM D412), Peel strength 880N/m (ASTM D903), Puncture resistance >950N. \n | 1206 | Sqm | |
292 | 1.291 | \nRetaining Wall Waterproofing\nSupplying and installation of single component, Pitch free polyurethane based Fosroc Nitoproof 600 PF - seamless, elastomeric water-proof coating.\ni. Retaining wall surface shall be made dry, clean, even and checked for soundness. Removal of oil, dirt, laitance and other contaminants by manually and surface shall be fairly smooth finish. \nii. Filling of tie rod holes if any using Conbextra GP2 mixed with water in ratio 0.16 \niii. Injection grouting of construction joints and honey combs with cementitious pressure grouting with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. \niv. Shamfering the floor wall junctions with cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement.\nv. Providing and applying waterproof coating using Nitoproof 600 PF, Pitch free Elastomeric Polyurethane coating over dry sruface at 1.5mm thick in 2 coats with interval period of 6 hours using spray / squeegee / roller / brush. The product shall be near zero-VOC, eco-friendly, single component liquid membrane.\nvi. Termination to be done on wall extending the coating to min.300mm height above the finished road level as per vendor recommendation.\n | 1227 | Sqm | |
293 | 1.292 | \nProtection board for Waterproofing - On completion of membrane application, providing and fixing of High compressive strength (not less 200Mpa) Dimple Board of 8mm thick as protective medium before soil filling.\n | 1227 | Sqm | |
294 | 1.293 | \nConstruction Joint / Starter Joint Treatment - Providing, Supplyinging, fixing and treating of construction joints/control joints, settlement joints etc as specified using single component, self sealing water swelling bars Supercast SW 20 made up of flexible polymer composites at joints of retaining walls and water retaining structures,foundations,floor slabs etc and wherever specified with proper overlaps at joints and over adhesive layer of Supercast SWX as per consultants approval at all levels as per drawings.\n | 2370 | Mtr | |
295 | 1.294 | \nWaterproofing of Fire Water, Raw Water, Treated Water, RO Tank, etc\nSupplying and installation of two component, Polymer modified waterproof coating Fosroc Nitocote CM 210 seamless, elastomeric water-proof coating.\ni. RCC floor and wall surfaces must be clean, even and sound. Remove all oil, dirt, laitance and other Contaminants by manually and surface shall be fairly smooth finish.\nii. Shamfering the floor wall joints in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement.\niii. Inlet and Outlet pipe - Annular space packing shall be done with Conbextra GP2 mixed with water and providing Supercast SWX as per manufacturerspecification.\niv. Water ponding for minimum 48 hours and injection grouting of construction joints, leaking spots and honey combs with cementitious pressure grouting with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar.\nv.Providing and applying waterproof coat using Nitocote CM210, an elastomeric cementitious coating at 2mm thickness using brush, trowel, squeegee in two coats at coverate of 3.8 Kgs / Sqm. Waterproofing product shall qualify the properties of withstanding cracked substrate cyclic movement from 0 - 300 - 0 microns at 15°C for 6,000 cycles without failure. It shall have the capability to resist a positive water pressure of 5 bar & a negative water pressure of 3 bar when tested to European standard CEN/TC 67-67072:2003 part A-7.\n | 2370 | Sqm | |
296 | 1.295 | \nProtective Coating for STP, Aeration, Filtered, Decant, Collection Tank, etc\nSupplying and installation of two component, solvent free coal tar modified epoxy Nitocote ET 402 for floor, wall and ceiling application\ni. RCC surface shall be made dry, clean, even and checked for soundness. Removal of oil, dirt, laitance and other contaminants by manually and surface shall be fairly smooth finish. ii. Filling of tie rod holes if any using Conbextra GP2 mixed with water in ratio:0.16 \niii. Injection grouting of construction joints and honey combs with cementitious pressure grouting with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. iv. Shamfering the floor wall junctions with cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement.\nv. Inlet Outlet Pipe Annular space packing using Conbextra GP2 mixed water and filling as per manufacturer's specification.\nvi. Imperfections and pin holes on the wall surfaces shall be smoothly renderd using Renderoc FC mixed with water in ratio 3:1\nvii. Floor shall be provided with 35mm average screed to slope in CC 1:2:4 mixed with Conplast WL @ 150ml per 50kg bag of cement by main contractor\nviii. Providing and applying high chemical and abrasion resistant coating Nitocote ET402 @ 400microns thickness in two coats using brush or squegee over epoxy primer layer of Nitoprime25.\n | 2370 | Sqm | |
297 | 1.296 | ARCHITECTURAL WORKS | |||
298 | 1.297 | MASONRYWORKS | |||
299 | 1.298 | \nProviding and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar using 30kgs/cum of masonry all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). \n | |||
300 | 1.299 | Basement Floor | 18 | Cum | |
301 | 1.3 | Ground Floor | 94 | Cum | |
302 | 1.301 | First floor | 113 | Cum | |
303 | 1.302 | Terrace floor | 35 | Cum | |
304 | 1.303 | \nExtra rate over & above Solid Masonry wall for providing RCC Binder 80 mm thick with M20 Grade reinforced cement concrete using coarse graded aggregate of 12 mm and downsize, reinforced with 4 Nos of 8 mm dia Fe500 grade steel and 6 mm dia Mild steel stirrups at 200 mm c/c and binders placed at intervals not more than 1000 mm, including cost of reinforcements and tying in position using binding wire made out of 18 gauge GI annealed, form work, scaffolding, all labour, hire and fuel charges for all tools and plants employed and all other incidental charges etc. all complete, as directed, in 150mm thick walls.\n | |||
305 | 1.304 | Basement Floor | 23 | Mtr | |
306 | 1.305 | Ground Floor | 97 | Mtr | |
307 | 1.306 | First floor | 128 | Mtr | |
308 | 1.307 | \nProviding and applying 10mm thick ceiling plaster including Staircase waist slab in cement mortar mix ratio CM 1:3 (1 Cement : 3 River sand), to internal surfaces of concrete work; including hacking concrete surfaces then applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate, preparing grooves, pattas, wattas, rounding of corners, etc. all complete as per architectural drawings, specifications and finished smooth with wooden rundha etc. or as specified; at all leads, depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces, curing, etc. complete as per specification and to the approval of the PMC/Employer.\n | |||
309 | 1.308 | Ground Floor | 1042 | Sqm | |
310 | 1.309 | First floor | 1043 | Sqm | |
311 | 1.31 | \nProviding and applying 15mm thick plaster in cement mortar mix ratio CM 1:4 (1 Cement : 4 River sand), to internal surfaces of concrete and masonry work; including raking out joints, hacking concrete surfaces and applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate \n | |||
312 | 1.311 | \nBasement Floor\n | 468 | Sqm | |
313 | 1.312 | Ground Floor | 1139 | Sqm | |
314 | 1.313 | First floor | 1302 | Sqm | |
315 | 1.314 | Terrace floor | 476 | Sqm | |
316 | 1.315 | \nProviding and applying minimum 18mm thick double coat cement sand plaster; first coat to be 12mm thick cement sand mortar of mix ratio CM 1:5 (1 Cement : 5 River sand) including adding 2% by weight of cement approved waterproofing compound of approved manufacturer, second coat to be 6mm thick in cement sand mortar of mix ratio CM 1:3 (1 Cement : 3 River sand), finished sand face or as required to receive specified architectural external finish to correct line, plumb and level to external faces of walls, sofits/ceiling if any, including hacking concrete surfaces then applying chemical adhesive coating and a scratch/dash coat as a positive bond, curing the same, racking out junctions of masonry and concrete, then pointing and grouting using non-shrinking compound, joints grouted by pressing square crushed stone, further providing 150mm wide 20 gauge GI chicken mesh at junctions of concrete and masonry work, doing independent double legged scaffolding etc.\nItem also include necessary scafolding, plastering to window sills, RCC cornices, making wattas, drip-moulds, bands, grooves etc., doing curing, cleaning, etc. all complete to the approval of the PMC/Employer. (To External Surfaces)\n | 1602 | Sqm | |
317 | 1.316 | \nFLOORING WORKS:- Providing and laying Granolithic flooring (Cement Flooring) of 80mm thick with cement concrete 1:1.5:3 ( 1 cement : 1.5 M- sand : 3 graded stone aggregate ) using 20mm hard broken stone aggregate laid to level or slope in bays not exceeding 3 sqm per panel including providing metal/glass strips to the full depth of the flooring and finishing the top with rubbed, smooth with power trowel, thread lining, curing, including all leads and lifts in all levels etc; complete all as per standard specifications. (The rate is inclusive of necessary planking for panelling wherever necessary as directed by the PMC / Employer Location:- Electrical room, Furniture storage, Compressor, AHU room, Convention & Conference Halls\n | |||
318 | 1.317 | Basement Floor | 499 | Sqm | |
319 | 1.318 | Ground floor | 866 | Sqm | |
320 | 1.319 | First floor | 957 | Sqm | |
321 | 1.32 | Terrace floor | 963 | Sqm | |
322 | 1.321 | \nProviding and laying 25mm thick machine cut, machine polished approved Kota stone flooring in pattern and size as detailed in drawing or as directed by the PMC/Employer. Stone to be bedded in 20mm thick cement mortar 1:6 (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, to required line, level; joints to be cleaned and grouted with matching colour approved quality readymade grout, curing, cleaning, polishing, protecting etc. all complete at all heights and leads to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.35/Sft) Location: Service Staircase Tread, Riser & landings\n | 229 | Sqm | |
323 | 1.322 | \nJOINERIES \nFD120 Fire rated doors - Painted Providing and fixing of Hollow metal Insulated fire rated doors as per IS 3614 part-1, for stability, integrity & insulation. Pressed galvanized steel conforming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire or third party certified or equivavelent lab, for maximum rating of 120mins with 30minutes of insulation, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label conforming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent.\nDoor frame shall be single rebate grooved profile of size 125 x 60mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff.\nDoor leaf shall be 46mm thick fully flush double skin door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density insulation material. Intumescent seals 15x2mm to be provided all around the door in addition to the grooved smoke seal. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include Supplying and installation of door, inclusive of Hardware fixing and exclusive of hardware Supplying as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.\nApplication: Staircase Exit 120Mins Fire Rated Door Double leaf of size : 1500 x 2100 with vision panel (200 x 300)with hardware set # \n\n | 7 | Nos | |
324 | 1.323 | \nSupplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of mechanical device chain and crank operation, providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters, 80x1.25 mm M.S. laths with 1.25 mm thick top cover as per Drawing No: TMA / CTC / GFC / ARCH / A55-C-R0 ( Size of the shutter - 4.0Mtr x 4.50Mtr )\n | 4 | Nos | |
325 | 1.324 | \nProviding, fabricating and fixing M.S. railing work as per drawing out of square bars / class ‘C’ pipes / tees / angles / flats / I sections / channels etc. including providing and fixing GI hold fast as necessary to the of RCC members / brick work, electric welding the joints and grinding smooth the welded joints to give one piece appearance including taking site measurements and preparing shop drawing, getting approval of shop drawing prior to fabrication from the PMC/Employ er, assembly finish with two coats of zinc phosphate primer and two coats of approved make and shade epoxy paint all complete to entire satisfaction of the PMC/Employer. (Location: Rear Staircase)\n | 946 | Kgs | |
326 | 1.325 | \nCEILING PAINT:- Providing and applying oil bound distemper of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels. (Rate is inclusive of Scrapping the existing RCC Surface and finishing joints smoothly with putty).\n | 1042 | Sqm | |
327 | 1.326 | \nINTERNAL EMULSION:- Providing and applying Acrylic emulsion paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); over 2 coats of suitable 1mm thick putty of approved manufacturer including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels.\n | 3383 | Sqm | |
328 | 1.327 | \nEXTERNAL PAINT:- Providing and applying Exterior Emulsion Paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor) of newly plastered wall surface with ready mixed paint of first class quality and approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., required scaffolding, leads and lifts at all levels.\n | 1602 | Sqm | |
329 | 2 | \nMULTILEVEL CARPARKING \n | |||
330 | 2.001 | \nSTRUCTURAL WORKS\n | |||
331 | 2.002 | \nFOUNDATION PILING:\n | |||
332 | 2.003 | \n650mm dia Pile Boring:- \nProviding and Installation bored Cast-in-situ reinforced cement concrete Piles of Grade M-30 Ready Mix Concrete having Minimum Cement Content as per IS 456 with necessary admixtures and plasticiser. Piles are end bearing piles of basic length 5.00 Mtr and additionally anchoring in the rock at bottom by 1.5 times dia of the piles in all types of soil with driving 8mm thickness of temporary steel casing with necessary stiffener bands and sharp edge at bottom; casing shall be provided up to non-collapsible strata from the existing ground level (as per Site condition), boring in over-burden and through all type of strata encountered up to the founding level as described in the drawing, socketing in approved strata, using bentonite slurry, including disposal of all bored materials etc.complete as per drawings and specifications. Rate is inclusive of Pile boring in all types of soil, Bentonite flushing, Cage lowering, Supplying and installation of concrete, Pile head chipping, Plant installation, collection of sub soil samples in each pile, etc., ( Length of pile for payment shall be measured from toe of pile to bottom of pile cap, Reinforcement will be paid separately ) In all types of soil such as Brownish Clay, Sandy Silty, Clayey sand, Very Dense Completely Weathered Rock etc., (Kindly refer soil report) \n | 4209 | Mtr | |
333 | 2.004 | \n650mm dia Pile Integrity testing:-\nPile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.\n | 443 | Nos | |
334 | 2.005 | \nPile Reinforcement works:- \nProviding, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as Pile, walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786. ( Note: Helical Reinforcement should be welded as per IS Standards, Authorized Laps, Spacer Bars and Chairs shall be measured for payment )\n | 132441 | Kgs | |
335 | 2.006 | \nCEMENT CONCRETE WORKS:- \n | |||
336 | 2.007 | \nProviding, machine mixing and laying Plain cement concrete (PCC) 1:4:8 ( 1 Cement : 4 sand : 8 graded stone aggregate 20mm nominal size ) of required thickness for foundation, rafts, plinth beams, levelling course and all locations, etc. (minimum cementitious content shall be as specified in the IS Code and as approved); including compacting, curing, required shuttering and its removal, dewatering where required and vibrating, cleaning, preparing surfaces, junctions, etc.; complete at all depths and leads as per the drawing and to entire satisfaction of the PMC/Employer. (Note: Using M - sand)\n | |||
337 | 2.008 | \nPilecap & Tie beam\n | 138 | Cum | |
338 | 2.009 | \nBelow Grade slab \n | 518 | Cum | |
339 | 2.01 | \nREINFORCED CONCRETE WORKS:- \n | |||
340 | 2.011 | \nProviding, transporting, pumping and laying batched design mixed, controlled concrete of different grade (as specified in the Structural drawings) conforming to (IS 456) with minimum cement content and maximum water cement ratio as per IS or as specified by Structural Consultant including using approved quality admixtures and placed either with pump / manual / lift for following grades of concrete including compacting, vibrating, curing and protecting etc., complete at all lead, lift & heights as per the drawing and to entire satisfaction of the PMC / Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. ( No separate payment will be made by the Employer towards wastage ). ( Note: Using M - sand )\n | |||
341 | 2.012 | M30 Grade Concrete - ( Sl. No 2.013 to 2.015 ) | |||
342 | 2.013 | Pilecap | 1318 | Cum | |
343 | 2.014 | Tie beam | 382 | Cum | |
344 | 2.015 | Grade slab | 647 | Cum | |
345 | 2.016 | M35 Grade Concrete - ( Sl. No 2.017 to 2.043 ) | |||
346 | 2.017 | Shear wall | |||
347 | 2.018 | Ground floor | 193 | Cum | |
348 | 2.019 | First floor | 150 | Cum | |
349 | 2.02 | Second floor | 150 | Cum | |
350 | 2.021 | Third floor | 150 | Cum | |
351 | 2.022 | Fourth floor | 150 | Cum | |
352 | 2.023 | Fifth floor | 150 | Cum | |
353 | 2.024 | Sixth floor | 150 | Cum | |
354 | 2.025 | Terrace floor | 136 | Cum | |
355 | 2.026 | Columns | |||
356 | 2.027 | Ground floor | 197 | Cum | |
357 | 2.028 | First floor | 159 | Cum | |
358 | 2.029 | Second floor | 159 | Cum | |
359 | 2.03 | Third floor | 159 | Cum | |
360 | 2.031 | Fourth floor | 159 | Cum | |
361 | 2.032 | Fifth floor | 159 | Cum | |
362 | 2.033 | Sixth floor | 159 | Cum | |
363 | 2.034 | Terrace floor | 80 | Cum | |
364 | 2.035 | Floor Slabs, Beams & Staircase | |||
365 | 2.036 | Ground floor | 1296 | Cum | |
366 | 2.037 | First floor | 1296 | Cum | |
367 | 2.038 | Second floor | 1296 | Cum | |
368 | 2.039 | Third floor | 1197 | Cum | |
369 | 2.04 | Fourth floor | 1197 | Cum | |
370 | 2.041 | Fifth floor | 1197 | Cum | |
371 | 2.042 | Sixth floor | 1197 | Cum | |
372 | 2.043 | Terrace floor | 165 | Cum | |
373 | 2.044 | FORMWORK:- | |||
374 | 2.045 | \nProviding, fabricating, erecting form work and deshuttering at all levels and places wherever needed/specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles.\n | |||
375 | 2.046 | Pile cap | 1862 | Sqm | |
376 | 2.047 | Pilecap tie beam | 1827 | Sqm | |
377 | 2.048 | Shear wall | 9483 | Sqm | |
378 | 2.049 | Columns | 6227 | Sqm | |
379 | 2.05 | Typical Floor Slab | 35613 | Sqm | |
380 | 2.051 | Typical Floor Beam | 5737 | Sqm | |
381 | 2.052 | Staircase | 986 | Sqm | |
382 | 2.053 | REINFORCEMENT WORKS:- | |||
383 | 2.054 | \nProviding, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786 ( Note:- Authorized Laps, Spacer Bars and Chairs shall be measured for payment )\n | 1.93801e+06 | Kgs | |
384 | 2.055 | POST TENSIONING WORKS:- | |||
385 | 2.056 | \nDesign and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, Supplyinging, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including Supplying of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the PMC / Employer. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Engineer-in-charge \nSupplying & execution of post tensioning work shall be carried out by approved specialized agency, with their own design, equipment, accessories & skilled manpower for satisfactory completion of work as per approved drawings. The contractor shall have minimum 5 years experienced technical staff for proper monitoring, ensuring & certifying the correctness of entire prestressing operations. Prestressing work shall be duly tabulated and report shall be submitted. Item also to include the required scaffolding etc. including marking the PT strand path locations for easy identification etc. all complete to the entire satisfaction of PMC / Employer. Refer Structural Drawing Nos. 1920002-CTC-MLCP-17 / 18 / 19 / 20 & 21\n | 142 | MT | |
386 | 2.057 | \nTerrace Waterproofing\nSupplying and installation of single component, Pitch modified polyurethane based Fosroc Nitoproof 600 Std - seamless, elastomeric water-proof coating\na) Surface Preparation- The cleaning and preparation of the substrate to which the Fosroc Nitoproof 600 Std is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application. Surface shall be maintained in dry condition before applying waterproof coating.\nb) Coving at Right Angle Junctions- All the right angle junctions between floor and wall shall be provided with coving of size 75mm x 75mm minimum 15mm thickness in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with Nitobond SBR.\nc) Down Take Pipe Packing- The pipes to be fixed should be filed in order to provided a proper bond and the same to be alligned by the respective agency. The annular space around the Rain water pipe shall be packed using Conbextra GP2, a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR on the core surface fixing leak free form work as per manufacturer's specification.\n | |||
387 | 2.058 | \nd) Pressure Grouting at Leaking points-Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. FIxing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification \ne) Waterproof coating-Providing and applying Fosroc Nitoproof 600 Std a single component pitch modified polyurethane based coating that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane. It is elastomeric, seamless waterproof membrane applied in 2 coats to DFT not less than 1.3 mm thick having a elongation capacity of over 600% . Termination to be done on wall extending the coating to min.300mm height above the finished floor level and sealed inside the groove of 20mm wide x 10mm thick flushed with polymer modified mortar as per vendor recommendation. Laying 200gsm non woven geo textile membrane over Nitoproof 600 Std coating with overlap sealed using synthetic rubber adhesive before providing screed concrete. The material shall comply to – ASTM C 836. Typical cured membrane properties (at 28 days), Elongation (ASTM D412) : 620 %,Specific gravity : 1.5 to 1.55 g/cc, Modulus @ 100% elongation (ASTM D412) : 0.62 N/mm²,Tear resistance (ASTM D624) : 15 N, Water vapour transmission(ASTM E96) : 9.7 g/m2/24 hrs., Permeability (ASTM E96) : 0.063 ng/m/sec/Pa*, Shore A hardness (ASTM D2240) : 50,Artificial weathering : No loss of flexibility after 4000 hours exposure, Extensibility after heat aging (min. requirement -extended to 6.4mm,without cracking) : No cracking or tearing, Service temperature (continuous ambient) : -40°C to 70°C.\n | 5219 | Sqm | |
388 | 2.059 | \nScreed Concrete to Slope\nFixing 3mm dia, 75mm square weld mesh over the geo textile surface followed by providing and laying screed concrete of M20 grade of average 75mm thickness with a minimum thickness of 50mm at drain points and a slope of 1:150 or required as per the site condition at all levels by admixing necessary admixtures Conplast WL @ 150ml per bag of cement and mixing Graded fibrillated 100% virgin poly propylene fibres in concrete at the rate of 0.90 kg/cum as per manufacturers specifications. Treatment to continue along the vertical surface for 300mm height in shape of round wata, curing etc. The concrete shall be provided with groove cutting of 6mm x 10mm at every 5m x 5m area, the joints shall be treated with elastomeric sealants Nitoseal PU 40. \n | 385 | Cum | |
389 | 2.06 | \nToilet Waterproofing\nSupplying and installation of two component, Polymer modified waterproof coating Fosroc Brushbond RFX seamless, elastomeric water-proof coating.\na) Surface Preparation-The cleaning and preparation of the substrate to which Fosroc Brushbond RFX is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application. Surface shall be maintained in SSD condition before applying waterproof coating.\nb) Coving at Right Angle Junctions-All the right angle junctions between floor and wall shall be provided with coving of size 75mm x 75mm minimum 15mm thickness in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with Nitobond SBR.\nc) Down Take Pipe Packing-The pipes to be fixed should be filed in order to provided a proper bond and the same to be alligned by the respective agency. The annular space around the drain pipe shall be packed using Conbextra GP2, a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR on the core surface fixing leak free form work as per manufacturer's specification.\n | |||
390 | 2.061 | \nd) Pressure Grouting at Leaking points-Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. Fixing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification\ne) Waterproof coating-Providing and applying waterproof coating using Brushbond RFX at 1mm thick in 2 coats at a coverage rate of 12 - 14 sqm per 20.88kg bag with interval period of 6 hours over a substrate with Saturated Surface Dry condition. Termination to be done on wall extending the coating to min.300mm height above the finished floor level and sealed in the termination groove of 20mm wide and 10mm deep flushed with polymer modified mortar as per vendor recommendation. The applied material of Brushbond RFX should have a weight loss of less than 1gm when tested for abrasion resistance according to ASTM-D4060,Tensile strength as per ASTM D638 is 2N/mm² Adhesion to concrete is greater than 1N/mm² and static crack accommodation of 1mm according to ASTM-C836. \n | 190 | Sqm | |
391 | 2.062 | \nProtective Plastering\nFine sand shall be sprinkled while the coating is in tacky condition. Providing and laying plastering of 12mm thickness in CM 1:4 mixed with integral waterproofing compound Conplast WL @ 150ml per bag of cement. System include necessary preparation, curing with water, chemicals used, labour, etc as per specification complete\n | 190 | Sqm | |
392 | 2.063 | ARCHITECTURAL WORKS | |||
393 | 2.064 | \nMASONRY WORKS\n\n | |||
394 | 2.065 | \nProviding and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar using 30kgs/cum of masonry all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).\n | |||
395 | 2.066 | Ground floor | 65 | Cum | |
396 | 2.067 | First floor | 66 | Cum | |
397 | 2.068 | Second floor | 66 | Cum | |
398 | 2.069 | Third floor | 66 | Cum | |
399 | 2.07 | Fourth floor | 65 | Cum | |
400 | 2.071 | Fifth floor | 65 | Cum | |
401 | 2.072 | Sixth floor | 65 | Cum | |
402 | 2.073 | Terrace floor | 83 | Cum | |
403 | 2.074 | \nProviding and applying 15mm thick plaster in cement mortar mix ratio CM 1:4 (1 cement : 4 River sand), to internal surfaces of concrete and masonry work; including raking out joints, hacking concrete surfaces and applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate; In All levels\n | 8680 | Sqm | |
404 | 2.075 | \nProviding and applying minimum 18mm thick double coat cement sand plaster; first coat to be 12mm thick cement sand mortar of mix ratio CM 1:5 (1 cement : 5 River sand) including adding 2% by weight of cement approved waterproofing compound of approved manufacturer, second coat to be 6mm thick in cement sand mortar of mix ratio CM 1:3 (1 cement : 3 River sand), finished sand face or as required to receive specified architectural external finish to correct line, plumb and level to external faces of walls, sofits/ceiling if any, including hacking concrete surfaces then applying chemical adhesive coating and a scratch/dash coat as a positive bond, curing the same, racking out junctions of masonry and concrete, then pointing and grouting using non-shrinking compound, joints grouted by pressing square crushed stone, further providing 150mm wide 20 gauge GI chicken mesh at junctions of concrete and masonry work, doing independent double legged scaffolding etc.\nItem also include necessary scafolding, plastering to window sills, RCC cornices, making wattas, drip-moulds, bands, grooves etc., doing curing, cleaning, etc. all complete to the approval of the PMC/Employer. (To External Surfaces)\n | 3514 | Sqm | |
405 | 2.076 | \nFLOORING WORKS:- Providing and laying approved first quality, colour, design and shade Vitrified Tiles 600mm x 600 mm x 10mm of approved make (conforming to IS 15622, water absorption less than 0.05%) flooring in pattern as detailed in drawing or as directed by the PMC/Employer. Tile to be bedded over minimum 20mm thick cement sand mortar mix ratio 1:6 (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 Kg/Sqm over cleaned surface and spreading neat cement paste using minimum cement about 4.5 Kg/Sqm over cement mortar bed, joints to be cleaned and grouted with matching colour approved quality ploymer based readymade grout, curing, cleaning, to required line, level, protecting till handing over including wastages all complete at all leads, lifts and heights to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.60/Sft ) Location:- Toilets\n | 431 | Sqm | |
406 | 2.077 | \nProviding and laying Granolithic flooring (Cement Flooring) of 80mm thick with cement concrete 1:1.5:3 ( 1 cement : 1.5 M- sand : 3 graded stone aggregate ) using 20mm hard broken stone aggregate laid to level or slope in bays not exceeding 3 sqm per panel including providing metal/glass strips to the full depth of the flooring and finishing the top with rubbed, smooth with power trowel, thread lining, curing, including all leads and lifts in all levels etc; complete all as per standard specifications. (The rate is inclusive of necessary planking for panelling wherever necessary as directed by the PMC / Employer. (The rate is inclusive of necessary planking for panelling wherever necessary as directed by the PMC / Employer Location:- Carpark\n | |||
407 | 2.078 | Ground floor | 5220 | Sqm | |
408 | 2.079 | First floor | 5312 | Sqm | |
409 | 2.08 | Second floor | 5555 | Sqm | |
410 | 2.081 | Third floor | 5162 | Sqm | |
411 | 2.082 | Fourth floor | 5162 | Sqm | |
412 | 2.083 | Fifth floor | 5162 | Sqm | |
413 | 2.084 | Sixth floor | 5162 | Sqm | |
414 | 2.085 | Terrace floor | 4685 | Sqm | |
415 | 2.086 | \nProviding and laying 25mm thick machine cut, machine polished approved Kota stone flooring in pattern and size as detailed in drawing or as directed by the PMC/Employer. Stone to be bedded in 20mm thick cement mortar (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, to required line, level; joints to be cleaned and grouted with matching colour approved quality readymade grout, curing, cleaning, polishing, protecting etc. all complete at all heights and leads to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.35/Sft) Location: Service Staircase Tread, Riser & landings)\n | 1990 | Sqm | |
416 | 2.087 | \nCLADDING WORKS:- Providing and fixing approved first quality, colour, design and shade Vitrified Tiles 600 x 600mm x 10mm of approved make (conforming to IS 15622 and EN 176 and water absorption less than 0.05%) dado to walls/columns, as shown in drawing or as directed by the PMC/Employer. Tile fixed over pre-plastered (12mm thick) masonry / RCC surfaces by using approved compatible adhesive (Bal / Laticrete or equivalent approved) over plastered surface to correct line, level and plumb. Joints are well cleaned and grouted with matching colour polymer based approved quality readymade grout and cured, cleaned, junctions with plaster finished smooth, etc. all complete at all heights and leads to the satisfaction of the PMC/Employer. ( Basic Price Rs.60/Sft ) Location:- Toilets\n | 910 | Sqm | |
417 | 2.088 | JOINERIES | |||
418 | 2.089 | \nABS DOOR / Equivalent\nProviding and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw. The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated. ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm. PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of ball bearing butterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work Design Pre-laminated door\n | 26 | Sqm | |
419 | 2.09 | \nFD120 Fire rated doors - Painted Providing and fixing of Hollow metal Insulated fire rated doors as per IS 3614 part-1, for stability, integrity & insulation. Pressed galvanized steel conforming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire or third party certified or equivavelent lab, for maximum rating of 120mins with 30minutes of insulation, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label conforming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent.\nDoor frame shall be single rebate grooved profile of size 125 x 60mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff.\nDoor leaf shall be 46mm thick fully flush double skin door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density insulation material. Intumescent seals 15x2mm to be provided all around the door in addition to the grooved smoke seal. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include Supplying and installation of door, inclusive of Hardware fixing and exclusive of hardware Supplying as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.\nApplication: Staircase Exit / Electrical rooms 120Mins Fire Rated Door Double leaf of size : 1500 x 2100 with vision panel (200 x 300)with hardware set # \n | 36 | Nos | |
420 | 2.091 | \nUPVC Window: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work\n | 84 | Sqm | |
421 | 2.092 | \nUPVC Ventilator: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work\n | 8 | Sqm | |
422 | 2.093 | \nProviding, fabricating and fixing M.S. railing work as per drawing out of square bars / class ‘C’ pipes / tees / angles / flats / I sections / channels etc. including providing and fixing GI hold fast as necessary to the of RCC members / brick work, electric welding the joints and grinding smooth the welded joints to give one piece appearance including taking site measurements and preparing shop drawing, getting approval of shop drawing prior to fabrication from the PMC/Employ er, assembly finish with two coats of zinc phosphate primer and two coats of approved make and shade epoxy paint all complete to entire satisfaction of the PMC/Employer. (Location: Staircase)\n | 4920 | Kgs | |
423 | 2.094 | \nCEILING PAINT:- Providing and applying oil bound distemper of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels. (Rate is inclusive of Scrapping the existing RCC Surface and finishing joints smoothly with putty).\n | 48611 | Sqm | |
424 | 2.095 | \nINTERNAL PAINT:- Providing and applying Acrylic emulsion paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); over 2 coats of suitable 1mm thick putty of approved manufacturer including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels.\n | 8690 | Sqm | |
425 | 2.096 | \nEXTERNAL PAINT:- Providing and applying Exterior Emulsion Paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor) of newly plastered wall surface with ready mixed paint of first class quality and approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., required scaffolding, leads and lifts at all levels.\n | 3514 | Sqm | |
426 | 2.097 | \nEXTERNAL FAÇADE:- Supplying & Installation of Aluminum Composite Panels for external wall cladding . The system shall be fixed using annodised aluminum box section for mullions, transform, galvanized steel bolts and nuts complete., all other necessary accessories. The bracket support shall be designed as per manufacturers specification. Fixing shall be done using powder coated rivets.\nNote: Cost includes, Aluminium profiles, Aluminium L-angles, GI brackets, self tapped screws, GI bolts & nuts, rivets, CNC Cutting, spacer tapes, sealants, labour, transport and Scafolding Charges.\nModel: Wood Series ACP from Aludecor ( 4mm thick with 0.5mm skin )\nAluminium Channel for framework 38mm x 25mm x 3mm L angles 50mm x 50mm x 2mm square tubes of Jindal or Equivalent\nHot Dip Galvanised Brackets 50mm x 50mm x 3mm Galvanised metal screws, Non rusting self tapping screws Spacer tapes - 3mm x 10mm (NORTON TAPES) DOWSEAL Weather Sealant 789\n | 389 | Sqm | |
427 | 3 | PLUMBING AND SANITARY WORKS | |||
428 | 3.001 | \nSANITARY FIXURES:-\nProviding and fixing in position White colour vitreous china European type Water Closet ( Wall Hung ) of approved make with 110 mm "P" or "S" trap connected with PVC pipe of 110mm dia with Polypropylene soft closed seat cover with CP brass hinges including cost of white cement for packing, spun yarn, teak wood plugs, brass screws, etc., Rate is inclusive of providing and fixing Single Piece Slim Concealed Cistern of 9 litre capacity tank, 40mm dia flush bend connected to tank and closet, necessary accessories, together with cutting and making good the walls, floors wherever required as directed by the Engineer-in-charge. ( Note: Model of EWC and flushing tank with all accessories should be got approved by the Employer ) \na) EWC - Wall-hung closet with seat cover of size ( L=361mm; H=365mm; W=535mm )\nb) Droplet faceplate polished \nc) Connector accessory pack \nd) M12 Rack bolts for wh installation\ne) Insta flush mech tank 3/6L w/o frame \nf) Angle Stop Valve\n | 152 | Nos | |
429 | 3.002 | \nProviding and fixing in position White colour vitreous china European Floor mounted Water Closet for Physically Challenged of approved make with 220 mm "P" or "S" trap connected with PVC pipe of 110mm dia with Polypropylene soft closed seat cover with CP brass hinges including cost of white cement for packing, spun yarn, teak wood plugs, brass screws, etc., Rate is inclusive of providing and fixing of Plastic Cistern of 9 litre capactiy tank, 40mm dia flush bend connected to tank and closet, Elbow operated knob, Foldable hinged arm, grab bar, down rails, C.P bolts, nuts, necessary accessories, together with cutting and making good the walls, floors wherever required as directed by the Engineer-in-charge. ( Note: Model of EWC and flushing tank with all accessories should be got approved by the Employer ) \na) EWC - Floor mounted closet 2 piece with seat cover of size ( L=365mm; H=765mm; W=673mm )\nb) Connector, rubber \nc) Cruz bath entry grip \nd) Angle Stop Valve\n | 7 | Nos | |
430 | 3.003 | \nProviding and fixing white colour vitreous china flat back half stall urinal with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps ( all in C.P. brass ) with waste fitting as per IS: 2556, PVC trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required ( Note: Model of Urinal & Sensor Kit with all accessories should be got approved by the Employer )\na) Urinal with rear inlet of size ( L=284mm; H=575mm; W=378mm; D=284mm )\nb) Standard Bottle Trap 300mm\nc) Urinal Sensor\n | 294 | Nos | |
431 | 3.004 | Providing and fixing of Ceramic White Urinal partition of approved make with necessary supports, bolts, nuts, etc., \nSize ( W=365mm; H=750mm; T=165mm ) | 273 | Nos | |
432 | 3.005 | \nProviding and fixing of white colour Under Counter wash Basin of approved make with basin piller cock, Bottle Trap, fully Casted Body, 32 mm dia pvc drain pipe of height 190 mm and 125 mm long Connecting Pipes & Wall Flange, Waste Coupling 32mm Size Half Thread with 130mm height and rubber adaptor for waste connection. Supplying of 1 no approved make CP angle cock together with 15mm brass nipple, 15mm dia nylone connection, including fixing of wash basin using CI brackets on the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water Supplying connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the Engineer-in-charge. ( Note: Model of wash basin with all accessories should be got approved by the Employer )\na) Ovel Shaped Under Counter Basin ( L=536mm; W=435mm )\nb) Piller Tap \nc) Angle Stop Valve\nd) Grid Drain With Over Flow Hole\ne) Standard Bottle Trap 300mm\n | 120 | Nos | |
433 | 3.006 | \nProviding & Fixing of Stainless steel Double bowl sink of approved make (48"x20"x8") with drain points for connect the waste couplers, with necessary supports, CI brackets, bolts, nuts at equal intervals, etc., Fixing of Double bowl sink, wall hook and angle valve, including wall chasing, making good the same, complete with standard specification and as directed by the Engineer-in-charge. ( Note: Model of Sink with all accessories should be got approved by the Employer )\na) Sink Folded edge gloss finish\nb) sink cock \nc) Angle Stop Valve\nd) Standard Bottle Trap 300mm\n | 4 | Nos | |
434 | 3.007 | Providing and fixing CP brass Paper holder roller in polished chrome of approved make complete with CP brackets fixed to wooden cleats with CP brass screws. | 159 | Nos | |
435 | 3.008 | Providing and fixing CP brass towel rail size of 600x20 mm of approved make complete with CP brackets fixed to wooden cleats with CP brass screws and washers complete. | 45 | Nos | |
436 | 3.009 | Supply & Fixing of approved make, no touch operting, fully hygienic hand drier of approved shade with single/double blower, with time delay, including providing necessary brackets, cable from drier to Plug, Plug top key and lock etc, complete as directed by the Engineer-incharge. | 31 | Nos | |
437 | 3.01 | Providing and fixing of approved make C.P. brass bib cock of approved quality conforming to IS:8931,18.49 15mm nominal bore | 32 | Nos | |
438 | 3.011 | Providing and fixing of approved make C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms,18.50 15 mm nominal bore | 4 | Nos | |
439 | 3.012 | Providing and fixing of superior quality of approved type and design of pedal operated Waste Bin in all Toilets. | 43 | Nos | |
440 | 3.013 | Providing and fixing of c.p. brass twin headed Double coat hook with all necessary screw fitting to complete | 159 | Nos | |
441 | 3.014 | Supply & fixing of approved make, matt finish Cockroach trap 125 x 125 mm SS floor grating with Hinge | 295 | Nos | |
442 | 3.015 | Providing and fixing of approved make, SS floor clean out | 96 | Nos | |
443 | 3.016 | Supply & Fixing of soap dispenser, push-button type, white/smoked with necessary fittings, etc., complete. | 45 | Nos | |
444 | 3.017 | Providing and fixing Health faucet along with wall fixing bracket, 1 m long flexible tube, making good the same, complete. | 159 | Nos | |
445 | 3.018 | WATER Supplying PIPES AND FITTNGS (INTERNAL AND EXTERNAL: | |||
446 | 3.019 | \nINTERNAL EXPOSED TO WALL:- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to ASTM D-2846, SDR11 upto 50mm dia & Sch 40 for above 50mm dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings that is Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings connection between CPVC & metal pipe/GI) ie. Brass Adaptors (both Male & Female threaded), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement conforming to ASTM F493 and testing of joints complete as per direction of Engineer in Charge. Rate Quoted shall be inclusive of cost of other consumables like hacksaw blade, solvent for CPVC pipe, etc. The work shall include Providing and fixing of necessary angles/channels for supports, chasing of walls, grouting of supports, painting of supports etc., complete.\n | |||
447 | 3.02 | 25 mm dia | 800 | Rmt | |
448 | 3.021 | 32 mm dia | 112 | Rmt | |
449 | 3.022 | 40 mm dia | 1237 | Rmt | |
450 | 3.023 | 50 mm dia | 83 | Rmt | |
451 | 3.024 | 65 mm dia | 95 | Rmt | |
452 | 3.025 | \nINTERNAL - CONCEALED WORK:- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to ASTM D-2846, SDR11 upto 50mm dia & Sch 40 for above 50mm dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings that is Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings connection between CPVC & metal pipe/GI) ie. Brass Adaptors (both Male & Female threaded), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement conforming to ASTM F493 and the cost of cutting chases, making good the same including testing of joints complete as per direction of Engineer in Charge. Rate Quoted shall be inclusive of cost of other consumables like hacksaw blade, solvent for CPVC pipe, etc.\n | |||
453 | 3.026 | 20 mm dia | 5307 | Rmt | |
454 | 3.027 | Providing and fixing male/ female screwed end full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated ball & teflon seat tested to a pressure 15 Kg / sqcm with (threaded joints) complete as required and as complete, as directed by Engineer-Incharge | |||
455 | 3.028 | 20 mm dia | 63 | Nos | |
456 | 3.029 | 25 mm dia | 354 | Nos | |
457 | 3.03 | 32 mm dia | 23 | Nos | |
458 | 3.031 | 40 mm dia | 11 | Nos | |
459 | 3.032 | 50 mm dia | 14 | Nos | |
460 | 3.033 | Providing and fixing of approved make C.I. body, EPDM seat, SS disc, Butterfly valve PN 16, SGI Hand lever operated, wafer ends conforming to BS:5155. The scope of work includes requried flanges to connect the pipes, etc.,as directed by Engineer-Incharge. | |||
461 | 3.034 | 65 mm dia | 48 | Nos | |
462 | 3.035 | 80 mm dia | 40 | Nos | |
463 | 3.036 | 100 mm dia | 23 | Nos | |
464 | 3.037 | 150 mm dia | 2 | Nos | |
465 | 3.038 | \nProviding and fixing of approved make of GM Non return valve, suitable for both horizontal & vertical application conforming to BS 1982 tested to a pressure of 15 Kg/sqcm. Including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required, shutter of brass/SS304 conforming to ASTM B159. as directed by Engineer-Incharge.\n | |||
466 | 3.039 | 50 mm dia | 2 | Nos | |
467 | 3.04 | 65 mm dia | 20 | Nos | |
468 | 3.041 | 80 mm dia | 15 | Nos | |
469 | 3.042 | 100 mm dia | 13 | Nos | |
470 | 3.043 | \nProviding and fixing Diapghram type, approved make pressure reducing station for cold water supply comprising of 3 nos CI butterfly valves on inlet, outlet, and bye-pass, conforming to BS5155, 1 Nos Gun metal pressure reducing valve with flanged connection, The complete system is tested to a pressure of 10 Kg/Sq.cm and suitable to reduce the pressure up to 2 Kg/Sq.cm) Including flanges, unions, nuts, bolts and washers complete as as directed by Engineer-Incharge.\n | |||
471 | 3.044 | 40 mm dia | 2 | Nos | |
472 | 3.045 | 50 mm dia | 2 | Nos | |
473 | 3.046 | 65 mm dia | 2 | Nos | |
474 | 3.047 | 80 mm dia | 2 | Nos | |
475 | 3.048 | Providing and fixing of of approved make automatic air release valve with 1/2 ball valve as directed by Engineer-Incharge. | 28 | Nos | |
476 | 3.049 | Providing and fixing of approved make 50mm dia, Brass float valve, complete brass body contruction, PN6 rating, with SS ball. The scope of work includes terminating the OHT inlet pipe and positioning for smooth operation. | 5 | Nos | |
477 | 3.05 | \nProviding and fixing GI. puddle flanges (IS 1239) fabricated out of 6 mm thick M.S. plate of size 300 x 300mm plus dia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.\n | |||
478 | 3.051 | 40 mm dia | 10 | Nos | |
479 | 3.052 | 50 mm dia | 10 | Nos | |
480 | 3.053 | 65 mm dia | 10 | Nos | |
481 | 3.054 | 80 mm dia | 10 | Nos | |
482 | 3.055 | 100 mm dia | 10 | Nos | |
483 | 3.056 | 150 mm dia | 10 | Nos | |
484 | 3.057 | EXTERNAL WATER Supplying & INTERNAL DRAINAGE | |||
485 | 3.058 | \nSOIL, WASTE & VENT: Providing and fixing of UPVC as per IS-13592, Type B with solvent 'weld type joints together UPVC pipes with necessary reducers if required, together uPVC pipe specials, vent cowls, of approved make, The pipes shall be duly fixed at site, with necessary cutting & jointing of pipe with approved quality jointing lubricant. The pipe shall be fixed properly aligned vertical with suitable MS pipe clamps. Work to include making necessary holes in the masonary walls etc.. and making good the damaged portions with mortar filling with 1:4 mix. Before handing over, leak test shall be carried out and any defects found shall be rectified. The work shall include Providing and fixing of necessary angles/ channels for supports, chasing of walls, grouting of supports, painting of supports etc., complete. Rate Quoted shall be inclusive of cost of cement, sand and other consumables like hacksaw blade etc.\n | |||
486 | 3.059 | 75 mm O.D pipe Type - B | 644 | Rmt | |
487 | 3.06 | 110 mm O.D pipe Type - B | 1117 | Rmt | |
488 | 3.061 | \nSupply of rigid PVC pipes as per IS 4985, 6Kg/Cm2 complete with necessary solvent cement joint fittings IS 7834 for drain piping between the bottle traps and up to the floor traps. Erection of the above pipe including cutting, jointing of the pipes with necessary fittings, encasings, erection of the pipes in wall chasing with necessary clamps and making good the chasings. Rate Quoted shall be inclusive of cost of cement, sand and other consumables like hacksaw blade etc.\n | |||
489 | 3.062 | 40 mm dia | 220 | Rmt | |
490 | 3.063 | 50 mm dia | 2076 | Rmt | |
491 | 3.064 | 75 mm dia | 600 | Rmt | |
492 | 3.065 | 110 mm dia | 300 | Rmt | |
493 | 3.066 | \nProviding and fixing in position deep seal multiway PVC floor Trap with cockroach trap and PVC extension piece of required length depth of following size to suit site conditions and multiple inlets, to suit site conditions with inlet sizes ranging from 40 mm to 75 mm. The bottom of the sump shall be dummied water tight. Wherever, sumps are shown to have water seal, the seal depth shall be minimum 40 mm. The sump shall be laid in cement concrete bed with 1:3:6 mix with 20 mm brick jelly bed all around. Providing and fixing heavy class C.P. brass mosquito proof grating with frame of approved design including setting in floor with cement mortar to match with floor finish. The scope of work includes making necessary sleeve arrangement in the slab.\n | 295 | Nos | |
494 | 3.067 | \nProviding, fixing, jointing and testing in position the spun cast iron pipe conforming to I.S. : 3989 cut to required lengths including all necessary fittings and specials such as Bends, Tees, junctions, offsets, access pieces (plain or door) & vent cowl. Fixing at wall/ceiling level supported by clamps & hangers etc. Making proper connection with refined pig lead joint of required depth including cutting, chases/holes in floors /walls/ slab etc and making good the same after pipe have been duly laid and testing complete. The scope work includes neccessary heavy clamps, Angles, supports etc., 17.35.1.2 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989\n | |||
495 | 3.068 | 100mm C.I Spun Pipe | 256 | Rmt | |
496 | 3.069 | 150 mm C.I Spun Pipe | 124 | Rmt | |
497 | 3.07 | \nProviding, fixing, jointing and testing of CI floor traps, making opening and neat core paking & water proofing around the floor trap without water leakage, necessary supports for holding the floor traps, with outlet 100mm\n | 36 | Nos | |
498 | 3.071 | \nProviding and fixing of approved make SS304 frame & removable 300x300x300 square frame & grating, making sleeve arrangement in the slab, core packings, water leak arrests, etc., chasing in the floor, fixing the grating support in the concrete, and making connection to the CI floor trap for kitchen area.\n | 36 | Nos | |
499 | 3.072 | \nRAINWATER PIPES & FITTINGS:- Providing and fixing of rigid PVC pipes as per IS 4985, 6Kg/Cm2, Class III, complete with necessary solvent cement joint fittings IS 7834 for drain piping between the bottle traps and up to the floor traps. Erection of the above pipe including cutting, jointing of the pipes with necessary fittings, encasings, erection of the pipes in wall chasing with necessary clamps and making good the chasings.\n | |||
500 | 3.073 | 200 mm OD pipes | 2762 | Rmt | |
501 | 3.074 | \nProviding and fixing of Approved 'make or Equivalent make roof drains, CI body with aluminium ring, with SS flat grate and screws including making necessary sleeve arrangement in the slab, core packings, water leak arrests, etc., chasing in the floor, fixing the grating support in the concrete, fixing the grating in the support and making connection to the rain water down coming pipe without any leak, painting the grating with one coat of primer and two coats of black enamel paint.\nRoof drains outlet 200mm Dia\n | 87 | Nos | |
502 | 3.075 | \nDesigning and constructing brick masonry inspection chamber of the following sizes in brick work of class 75 in cement mortar 1:5 (1 cement:5 fine sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm. nominal size) embeded with frame for manhole, RCC foundation slab. 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone aggregate 40 mm nominal size) both inside and outside of plastering 12 mm thick with cement motar 1:3 (1 cement : 3 coarse sand) with a floating coat of neat cement on inside face, proper water proofing to ensure no ground water seepage in the manhole, Poly propylene (conforming to ASTMD - 4101) foot rests (meeting the 224 kg load requirement as per IS 5455) at 300 mm spacing, benching and making channels with 1:2:4 cement concrete neatly finished, including necessary centering and shuttering, reinforcement, excavation, in all kind of soil, dewatering, refilling, watering, ramming and removing the surplus excavated earth, making good the same complete as required with 600x600 approved make Heavy duty cover and frame not less than 208kg, (Weight of cover 108kg and weight of frame 100kg). 120Cm x 75Cm size upto 90Cm\n | 30 | Nos | |
503 | 3.076 | \nConstruction of percolation well / rain water harvest pit of of required internal dimension of 1.2mtr Dia upto 2.5 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement, With perforated RCC cover, fixed over 100 mm P.C.C, Rungs, etc. The work shall include necessary exacavation and backfilling placing 2 nos of 200mm dia slotted pie for 5mtr from the bottom of the catch pit, 25mm coarse aggregate (black pebbles) for filteration.\n | 64 | Nos | |
504 | 3.077 | EXTERNAL DRAINAGE | |||
505 | 3.078 | \nSEWERAGE LINE:- Providing, fixing, jointing and testing in position the following UPVC pipes confirming to IS:4985 of 10 Kg / Sq.cm for drainage system cut to required length. The pipes shall be duly laid at site, with necessary cutting & jointing of pipe with approved quality jointing lubricant. The pipes shall be fixed properly aligned and laid to slope. Before handing over, leak test shall be carried out and any defects found shall be rectified. Work shall also include necessary excavation and back filling 'with compaction etc, as directed by Engineer- Incharge (For sewer and Sullage line)\n | |||
506 | 3.079 | 75mm dia | 13 | Rmt | |
507 | 3.08 | 110mm dia | 83 | Rmt | |
508 | 3.081 | 160mm dia | 64 | Rmt | |
509 | 3.082 | 200mm dia | 94 | Rmt | |
510 | 3.083 | 250 mm dia | 103 | Rmt | |
511 | 3.084 | \nSupply of Glazed stoneware gully trap of size 150 x 100 mm with 100 mm outlet, CI grating to suit the size of the gully mouth, CI cover & frame of 300 x 300 mm clear opening of 7 kg weight, complete. Laying in position the above glazed stone ware gully trap including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm inside clear in brick masonry, 15 mm thick plaster with cement mortar (1:3) on both internal and external surfaces, inside finished with floating coat of neat cement. Fixing C.I frame and cover 300 x 300 mmX7 kgs wt (clear opening), cover painted with 2 coats of anti-corrosive black bitumastic paint etc., complete. The work shall include necessary excavation and backfilling. ( Air tight heavy duty covers for gully traps which falls in parking area )\n | 10 | Nos | |
512 | 3.085 | \nConstruction of sewer chambers of required internal dimension of 600x600mm depth upto 0.8 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement. Neco make Heavy duty DI manhole cover with hinged frame. fixed over 100 mm P.C.C. including painting of the frame, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include top slab of aroungd 150mm concrete structure for the mentioned size & making arrangement for manhole cover seating, necessary exacavation and backfilling.\n | 10 | Nos. | |
513 | 3.086 | \nConstruction of sewer chambers of required internal dimension of 600x750mm depth upto 1.0 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement. Neco make Heavy duty DI manhole cover with hinged frame. fixed over 100 mm P.C.C. including painting of the frame, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include necessary exacavation and backfilling.\n | 5 | Nos. | |
514 | 3.087 | \nConstruction of sewer chambers of required internal dimension of 600x900mm upto 1.2 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement. With 600X600 Neco make Heavy duty DI manhole cover with hinged frame. fixed over 100 mm P.C.C. including painting of the frame, rugs for accessing, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include top slab of aroungd 150mm concrete structure for the mentioned size & making arrangement for manhole cover seating, necessary exacavation and backfilling.\n | 4 | Nos. | |
515 | 3.088 | \nConstruction of sewer chambers of required internal dimension of 1200x1200mm upto 2.0 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement. Neco make 600X600 Medium duty DI manhole cover with hinged frame. fixed over 100 mm P.C.C. including painting of the frame, rugs for accessing, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include top slab of aroungd 150mm concrete structure for the mentioned size & making arrangement for manhole cover seating, necessary exacavation and backfilling.\n | 6 | Nos. | |
516 | 3.089 | \nDesigning and constructing brick masonry inspection chamber of the following sizes in brick work of class 75 in cement mortar 1:5 (1 cement:5 fine sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm. nominal size) embeded with frame for manhole, RCC foundation slab. 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone aggregate 40 mm nominal size) both inside and outside of plastering 12 mm thick with cement motar 1:3 (1 cement : 3 coarse sand) with a floating coat of neat cement on inside face, proper water proofing to ensure no ground water seepage in the manhole, Poly propylene (conforming to ASTMD - 4101) foot rests (meeting the 224 kg load requirement as per IS 5455) at 300 mm spacing, benching and making channels with 1:2:4 cement concrete neatly finished, including necessary centering and shuttering, reinforcement, excavation, in all kind of soil, dewatering, refilling, watering, ramming and removing the surplus excavated earth, making good the same complete as required with 600x600 approved make Heavy duty cover and frame not less than 208kg, (Weight of cover 108kg and weight of frame 100kg).\n | |||
517 | 3.09 | 120Cm x 75Cm size upto 90Cm | 25 | Nos | |
518 | 3.091 | 120Cm x 75Cm size upto 90Cm | 25 | Nos | |
519 | 3.092 | Extra for depth for manholes for 100Cm | 20 | Rmt | |
520 | 3.093 | \nProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to ASTM D-2846, SDR11 upto 50mm dia & Sch 40 for above 50mm dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings that is Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings connection between CPVC & metal pipe/GI) ie. Brass Adaptors (both Male & Female threaded), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement conforming to ASTM F493 and testing of joints complete as per direction of Engineer in Charge. Rate Quoted shall be inclusive of cost of other consumables like hacksaw blade, solvent for CPVC pipe, etc.\n | |||
521 | 3.094 | 50 mm dia - SDR 11 | 269 | Rmt | |
522 | 3.095 | 65 mm dia - Sch 40 | 334 | Rmt | |
523 | 3.096 | 80 mm dia - Sch 40 | 387 | Rmt | |
524 | 3.097 | \nSupply and installation of approved make CI manhole cover size 600x600 with theft proof hinged frame. fixed over 100 mm P.C.C. including painting of the frame, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include necessary exacavation and backfilling.\n | |||
525 | 3.098 | Medium duty, Grade B-125, 600mm x 600mm | 20 | Nos | |
526 | 3.099 | Light duty Grade A-15, 600mm x 600mm | 8 | Nos | |
527 | 3.1 | UTILITY PUMPS | |||
528 | 3.101 | \nSupply & Fixing of Water supply Hydro Pneumatic System Pumps, approved make Variable flow 2 Pump system, 2 working + 1 stand by, For pumping the Domestic water from sump to proposed campus. The cost shall include necessary Control Valves, pressure vessel, pressure switch, Non-Return Valves, interconnecting pipes in the system, foot valves, etc., 20m3/Hr@ not less than 46mtr Head, Each Pumps shall deliver 10m3/hr @ head of 46mtr with necessary starter, starter panel and cabling With required Pressure vessel of welmet make, The electrical contractor will leave the cable near the pump room with MCB or MCCB. The PHE contractor shall consider the cabling from the MCB or MCCB to individual pumps and starters. apprx length of cable shall be 20 RMT.\n | 1 | Set | |
529 | 3.102 | \nSupply & Fixing of Water supply Hydro Pneumatic System Pumps, of approved make Variable flow 2 Pump system, 2 working + 1 stand by, For pumping the Flush water from sump to proposed campus. The cost shall include necessary Control Valves, pressure vessel, pressure switch, Non-Return Valves, interconnecting pipes in the system, foot valves, etc., 20m3/Hr@ not less than 46mtr Head, Each Pumps shall deliver 10m3/hr @ head of 46mtr with necessary starter, starter panel and cabling With required Pressure vessel of welmet make, The electrical contractor will leave the cable near the pump room with MCB or MCCB. The PHE contractor shall consider the cabling from the MCB or MCCB to individual pumps and starters. apprx length of cable shall be 20 RMT.\n | 1 | Set | |
530 | 3.103 | \nSupply & Fixing of Water supply Hydro Pneumatic System Pumps, of approved make Variable flow 1 Pump system, 1 working + 1 stand by, For pumping the RO water from sump to proposed campus. The cost shall include necessary Control Valves, pressure vessel, pressure switch, Non-Return Valves, interconnecting pipes in the system, foot valves, etc., 10m3/Hr@ not less than 40mtr Head, Each Pumps shall deliver 10m3/hr @ head of 46mtr with necessary starter, starter panel and cabling With required Pressure vessel of welmet make, The electrical contractor will leave the cable near the pump room with MCB or MCCB. The PHE contractor shall consider the cabling from the MCB or MCCB to individual pumps and starters. apprx length of cable shall be 20 RMT.\n | 1 | Set | |
531 | 3.104 | \nSupply and installation of approved make, sewage submersible transfer cutter version pump with solid handling capacity of 40mm, Head Vertical height of 25Mtr, Flow 15m3/Hr, (1W+1S) with complete connections, float switches, drain points, required coupling valves,non return valves, control panel, required wiring between panel and motors, required pump supports - Sewage & Waste Disposal collection pit.\n | 1 | Set | |
532 | 3.105 | \nSupply and installation of approved make, submersible Dewatering non clog pump (1working + 1 stand by), 75m3/Hr vertical height of 15 mtr, with complete connections, float switches, drain points, required couplings, valves, non return valves, stater panel, required cabling between panel and motors, required pump supports and pulling threads, etc., - Rain Water storage Area.\n | 2 | Set | |
533 | 3.106 | \nSupply and installation of approved make, submersible water transfer pump, Head Vertical height of 25Mtr, Flow 15m3/Hr, (1W+1S) with complete connections, float switches, drain points, required coupling valves,non return valves, control panel, required wiring between panel and motors, required pump supports - Rain Water Storage.\n | 3 | Set | |
534 | 3.107 | \nProviding and fixing Position in MS angles/channels for supports, grouting of supports, for laying pipes at terrace floor, Pump rooms, service corridor, painting of supports etc., complete. The work shall also include painting of the entire supports, with one coat of Zinc Chromate primer & Two coats of approved make enamel paint the color shade shall be recommended by the client to suit the wall background. \n | 3940 | Kgs | |
535 | 3.108 | \nDrilling of Borewells anywhere in TamilNadu including transportation from one place to another with in TamilNadu in alluvial soil sedimentary strata of clay and sand stone shale pennles boulders etc. By first taking a pilot bore of 140mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drilling at site.- Up to 60m depth ending below ground level. (2 Nos borewells each 120 RM).\n | |||
536 | 3.109 | Up to 60m depth ending below ground level. | 120 | Rmt | |
537 | 3.11 | From 60m upto 90m Depth ending from ground level | 60 | Rmt | |
538 | 3.111 | From 90m upto 120 m Depth ending from ground level | 60 | Rmt | |
539 | 3.112 | Up to 60m depth ending below ground level. | 120 | Rmt | |
540 | 3.113 | From 60m upto 90m Depth ending from ground level | 60 | Rmt | |
541 | 3.114 | From 90m upto 120 m Depth ending from ground level | 60 | Rmt | |
542 | 3.115 | \nLabour Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor.\n | 16 | Hour | |
543 | 3.116 | \nLabour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer.\n | 240 | Rmt | |
544 | 3.117 | Supply and fixing of 160mm dia PVC special Blue pipes for Borewells | |||
545 | 3.118 | Plain pipes | 120 | Rmt | |
546 | 3.119 | Slotted special blue pipes | 120 | Rmt | |
547 | 3.12 | Suply and erection of 3HP Submerssible pumpset suitable for 150mm dia Borewell with ISI mark IS8034 with Panel board DOL with two level Guard and Auto start. The cost including all taxes and the panel board should be provided as per specification given with erection charges. | 2 | Nos. | |
548 | 3.121 | Supply and run of 4 sq.mm 3 core flat type copper cable | 340 | Rmt | |
549 | 4 | \nPROVIDING ELECTRICAL WORKS \n\nHT Panel Installation & Transformer \n | |||
550 | 4.001 | \nEstablisment of 33kv receiving station \nOut door type- 33kv ring main gear unit\nSupply, Erection, Testing and commissioning of 1 set of totally enclosed, floor standing, sheet steel clad cubicle pattern Outdoor type RMG Panel 33 KV HT Switch Board, consist 2nos of 33KV 1250A VCB as incomer and 1 no of 33KV 1250A VCB as outgoing panel with one set of 1500 amps coloured PVC sleeved copper bus bars and accessories as per detailed specification , Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 and TANGEDCO latest norms.\n | 1 | Set | |
551 | 4.002 | \nout door type- 33kv single VCB metering panel \nSupply, Erection, Testing and commissioning of 1 set of totally enclosed, outdoor type floor standing, sheet steel clad cubicle pattern 1 Panel 33 KV (Metering Panel) HT Switch Board, 1 no of 33KV 1250A VCB as Incomer one set of 1500 amps coloured PVC sleeved copper bus bars and accessories as below and as per detailed specification , Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 | 1 | Set | |
552 | 4.003 | Establisment of 33kv sub station \nIndoor type- 33kv HT 7 panel \nSupply, Erection, Testing and commissioning of 1 set of totally enclosed, indoor type floor standing, sheet steel clad cubicle pattern 7 Panel 33 KV HT Switch Board, 1 no of 33KV 1250A VCB as Incomer and 4Nos of 33KV 630A VCB as outgoing panel and 2Nos of 33KV 1250A VCB as buscoupler panel with Mechanical + Electrical interlock and provide one set of 1500 amps coloured PVC sleeved copper bus bars and accessories including (BATTERY CHARGER –BATTERY – DC PANEL SYSTEMS)\nSupply & fixing of Battery charger should be 110VDC/60Amps output capacity and input should 415VAC with auto/Manual control, Triple/boost charging mode with fully automatic control.\nBattery should be 110V/200AH battery tubular battery.\nDC panel with 10 output and 100Amps MCB with input, Overvoltage /under voltage, Earth leakage protection and dc cable as required,etc..should be provide as per revised technical specification and Refer Revised Single line diagram, Drawing no TM-082-CH-CTC-GFC-EL-SLD-E-01-R0 | 1 | Set | |
553 | 4.004 | \nOut door type-4 MVA Power TR-1,2&3:\nSupply, Erection, Testing & commissioning of Outdoor type 4 MVA ,3 phase , 50Hz, 33KV/11KV, DYn 11, Impedance 7.5%(Suitable operation of Parallel Concept) , 3 Phase ONAF type copper wound transformer with ON LOAD TAP CHANGER without AVR &with RTTC Panel as per IS 2026, with all standard accessories. The transformer shall be having cable end box capable of receiving 1 No. 3 X 300 sq. mm. XLPE HT 33 KV Cable on HV side and 1 No. 3 X 300 sq. mm. XLPE HT 11 KV Cable on LV side, complete with all accessories as per specification , Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 | 3 | Each | |
554 | 4.005 | \nINDOOR TYPE- 11KV HT 9 PANEL :- Supply, Erection, Testing and commissioning of 1 set of totally enclosed, Indoor type floor standing, sheet steel clad cubicle pattern 9 Panel 11 KV HT Switch Board consistsing of 3 nos of 11KV 630A VCB as Incomer and 4 Nos of 11KV 630A VCB as outgoing panel and 2no. of 11KV 630A VCB as Bus coupler with Mechanical + Electrical interlock and provide one set of 1500 amps coloured PVC sleeved copper bus bars, Surge arrester , accessories and as per detailed specification and Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 | 1 | Set | |
555 | 4.006 | \nEstablisment of 11kv sub station \nIndoor type- 11kv HT 8 panel :- Supply, Erection, Testing and commissioning of 1 set of totally enclosed, Indoor type floor standing, sheet steel clad cubicle pattern 8 Panel 11 KV HT Switch Board consistsing of 2 nos of 11KV 630A VCB as Incomer and 5 Nos of 11KV 630A VCB as outgoing panel and 1 no. of 11KV 630A VCB as Bus coupler with Mechanical + Electrical interlock and provide one set of 1500 amps coloured PVC sleeved copper bus bars, Surge arrester , accessories and as per detailed specification and Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 | 1 | Set | |
556 | 4.007 | \nOut door type-2000 KVA TR:-\nSupply, Erection, Testing & commissioning of Outdoor type 2000KVA ,3 phase , 50Hz, 11 KV/433 V, DYn 11, Impedance 6.25% (Suitable operation of NON Parallel Concept) , 3 Phase ONAN type copper wound transformer with ON LOAD TAP CHANGER with AVR & with RTTC Panel as per IS 1180, Level-II, with all standard accessories. The transformer shall be having cable end box capable of receiving 1 No. 3C X 240 sq. mm. XLPE HT 11 KV Cable on HV side and Flanges on LT side suitable for bus duct arramgement, complete with all accessories as per detailed specification and Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 . | 4 | Each | |
557 | 4.008 | \nHT Cable & End Termination\nSupply and laying of following sizes of Aluminium conductor cable, 33 KV (E) and 11 KV (E) grade, XLPE, Single steel tape armoured, HV cable 3 core cable direct in ground including excavation, sand cushioning, protective covering, refilling the trench and provide the hume pipe where ever required road crossing etc. and as per specification\n | |||
558 | 4.009 | 33 KV 3C 300 sq.mm. XLPE Armoured Cable .from RMG to metering panel & Metering panel to 33KV HT 5 panel. | 295 | Metre | |
559 | 4.01 | 33 KV 3C 300 sq.mm. XLPE Armoured Cable form 33KV HT 5 panel to Primary side of 4MVA power transformers. | 222 | Metre | |
560 | 4.011 | 11 KV 3C 300sq.mm. XLPE Armoured Cable. From 4MVA secondary side to 11KV HT 9 panel. | 178 | Metre | |
561 | 4.012 | 11 KV 3C 300sq.mm. XLPE Armoured Cable. From HT 9 Panel to 11KV HT 8 panel . | 926 | Metre | |
562 | 4.013 | 11 KV 3C 300sq.mm. XLPE Armoured Cable. From HT 9 Panel to 11KV HT 6 panel at Existing Utility building . | 35 | Metre | |
563 | 4.014 | 11 KV 3C 240sq.mm. XLPE Armoured Cable. From 11KV HT 8 panel to 11KV/0.433KV Distribution transformer. | 156 | Metre | |
564 | 4.015 | \nSupplying and making end cable termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 33KV XLPE aluminuim conductor of 3 core, 300 sqmm cable. \n | 12 | Each | |
565 | 4.016 | \nSupplying and making end cable termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 11KV XLPE aluminuim conductor of 3 core, 300 sqmm cable. \n | 12 | Each | |
566 | 4.017 | \nSupplying and making end cable termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 11KV XLPE aluminuim conductor of 3 core, 240 sqmm cable. \n | 8 | Each | |
567 | 4.018 | \nSupplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for 33KV XLPE aluminuim conductor of 3 core,300 sqmm cable. \n | 2 | Each | |
568 | 4.019 | \nSupplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for 11KV XLPE aluminuim conductor of 3 core,240 sqmm cable. \n | 4 | Each | |
569 | 4.02 | \nSupply,laying,testing and commissioning of control cable size 24 core 2.5 sqmm PVC insulated, PVC sheathed armoured copper conductor cable. \n | 120 | Metre | |
570 | 4.021 | Supply, terminations,testing and commissioning of control cable size 24 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. | 8 | Each | |
571 | 4.022 | Supply,laying,testing and commissioning of control cable size 16 core 2.5 sqmm PVC insulated, PVC sheathed armoured copper conductor cable. | 30 | Metre | |
572 | 4.023 | Supply, terminations,testing and commissioning of control cable size 16 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. | 6 | Each | |
573 | 4.024 | Supply,laying,testing and commissioning of control cable size 12 core 2.5 sqmm PVC insulated, PVC sheathed armoured copper conductor cable. | 40 | Metre | |
574 | 4.025 | Supply, terminations,testing and commissioning of control cable size 12 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. | 8 | Each | |
575 | 4.026 | Supply,laying, testing and commissioning of control cable size 7 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. | 120 | Metre | |
576 | 4.027 | Supply, terminations,testing and commissioning of control cable size 7 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. | 8 | Each | |
577 | 4.028 | Supply,laying, testing and commissioning of control cable size 3 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. | 60 | Metre | |
578 | 4.029 | Supply, terminations,testing and commissioning of control cable size 3 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. | 6 | Each | |
579 | 4.03 | Electrical cables, LT panels ,Wiring & Light fixtures ,Earthing etc. | |||
580 | 4.031 | \nLT panel board\nMain MV panel -3\nSupply, Installation, Testing and Commissioning of Medium Voltage floor mounting Cubicle Type Single bus bar system Panel Board suitable for 415 V, 3 Phase, 50 Hz Power Distribution System with the following mounting complete as per specifications attached.\nA) Incomer - 2Nos. For Transformer 5 & 6 : \n3200 AMPS ACB, 65 KA (Ics) AC Motor operated Draw Out ( EDO ) Type Four Pole Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:- 1No - Class 1.0, Digital Maximum Demand Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc.\n1No - Multi control relay for contorl of Under voltage, Over voltage, Single phase preventor, Phase rotation, with control fuses wiring etc.\n3Nos. - 3200/5A CL-1, 15VA current transformer with CT short link terminal block for Maximum demand Meter.\n1 No. - CDG11 Earth Fault relay \n4 No. 3200/5A 5P10 15VA Current transformer with CT short link terminal block for Earth fault relay\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\n3 No. 3200/5A CL-1, 15VA Current transformer with CT short link terminal block for APFCR relay.\n | |||
581 | 4.032 | Continue above\nB) Bus Coupler - 1Nos. :\n3200 AMPS , 65 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole ACB with out protection 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications. 1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse. TNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\nC) Outgoing - Part - A \n1 Nos. of 1600 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n4 Nos. of 1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications. | |||
582 | 4.033 | \nContinue above\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\nD) Outgoing - Part - B\n1Nos. of 1600 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. -1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n | |||
583 | 4.034 | Continue above\n4 Nos. of 1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n1Nos 400 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 400/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\n | 1 | Each. | |
584 | 4.035 | \nMain MV panel - 4\nSupply, Installation, Testing and Commissioning of Medium Voltage floor mounting Cubicle Type Single bus bar system Panel Board suitable for 415 V, 3 Phase, 50 Hz Power Distribution System with the following mounting complete as per specifications attached.\nA) Incomer - Transformer 7 & 8 :\n3200 AMPS ACB, 65 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping . as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Maximum Demand Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n1No - Multi control relay for contorl of Under voltage, Over voltage, Single phase preventor, Phase rotation, Reverse Power with control fuses wiring etc.\n3Nos. - 3200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1 No. - CDG11 Earth Fault relay \n4 No. 3200/5A 5P10 15VA Current transformer with CT short link terminal block for Earth fault relay\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\n3 No. 3200/5A CL-1, 15VA Current transformer with CT short link terminal block for APFCR relay.\n | |||
585 | 4.036 | \nContinue above\nB) DG Incomer 1 & 2 :\n2500 AMPS ACB, 65 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,ShutterAssembly,Racking interlock Manual /Electrical closing& tripping . as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 2500/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1 No. - CDG11 Earth Fault relay \n1No - Multi control relay for contorl of Under voltage, Over voltage, Single phase preventor, Phase rotation, Reverse Power with control fuses wiring etc.\n4 No. 2500/5A 5P10 15VA Current transformer with CT short link terminal block for Earth fault relay\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\nC) Bus Coupler - 1Nos. :\n3200 AMPS , 65 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole ACB with out protection 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\n | |||
586 | 4.037 | \nContinue above\nD) Outgoing - Part - A\n1Nos. of 1600 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1 No. of 1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n2 No. of 1000 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1000/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n\n | |||
587 | 4.038 | \nContinue above\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 630/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\n2 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\nE) Outgoing - Part - B\n1Nos. of 1600 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n | |||
588 | 4.039 | \nContinue above\n3Nos. - 1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1Nos. of 1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1Nos. of 800 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 800/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n4Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n | |||
589 | 4.04 | \nContinue above\n4 Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 630/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\n2 Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\nG) Busbar :\n3200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves.\nNote: To be provide 1No+1Nc potential free contact terminal block with wiring for all incoming and outgoing breakers for BMS.Electrical & Mechanical Interlock to be provide for all incomer and buscoupler.PLC Automatic EB and DG changeover system to be provide as per the logic ref.main SLD.\nAutomatic Fire extinguiser arrangement to be provide for all incomer and outgoing feeder compartment as per the CEA & CEIG norms.\n | 1 | Each | |
590 | 4.041 | \nMLSB \nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protect\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 630/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n630A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
591 | 4.042 | \nMPSB \nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 630/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n5Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n630A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. | 1 | Each | |
592 | 4.043 | \nMain feeder piller-1 \nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer:\n1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n12 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n1250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
593 | 4.044 | \nMain feeder piller-2\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer:\n800 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 800/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n8 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n800A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
594 | 4.045 | \nMain AHU panel-1 ( for hall 1,2,3&4)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1000 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1000/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n2 Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n8 Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n1000A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
595 | 4.046 | \nMain AHU panel - 2 (for exhibition hall - 5 & conventional hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1000 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1000/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lam ps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n2 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n6 Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n1000A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
596 | 4.047 | \nMain AHU panel - 3 (conference hall & pre function lobby)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 400 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 400/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n400A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
597 | 4.048 | \nAHU Panel - 1 (Exhibition hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
598 | 4.049 | \nAHU panel - 4,6 (Exhibition hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n5Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 2 | Each | |
599 | 4.05 | \nAHU panel - 2,3,5,7,8 (Exhibition hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 5 | Each | |
600 | 4.051 | \nAHU panel - 1,2 (Exhibition hall-5)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n6Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 2 | Each | |
601 | 4.052 | \nAHU panel - 3,4 ,5 6(convention hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 4 | Each | |
602 | 4.053 | \nAHU panel - 1 (pre function lobby & conference hall-1)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n4Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
603 | 4.054 | \nAHU panel - 2 (conference hall - 2&3)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n5Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
604 | 4.055 | \nMain AHU & ventilation panel -5 (Utility block)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n8Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n400A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
605 | 4.056 | \nMain ventilation panel\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer 1 & 2 \n1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type Four Pole Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n2 Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2 Nos 400 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n1250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n\n | 1 | Each | |
606 | 4.057 | \nSub main ventilation panel - 1 (GF exhibition hall-1,2,3&4)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 630/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n5Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n630A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n | 1 | Each | |
607 | 4.058 | \nSub main ventilation panel - 2 (ff exhibition hall-5, convention hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 315 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 315/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n4Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n315A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
608 | 4.059 | \nSub main ventilation panel - 3 (terrace)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n2Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
609 | 4.06 | \nVentilation panel - 1,2,3&4 (exhibition hall-1,2,3&4)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n9Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 4 | Each | |
610 | 4.061 | \nVentilation panel - 5 (exhibition hall-5 )\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n6Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n\n | 1 | Each | |
611 | 4.062 | \nVentilation panel - 6 (convention hall )\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n11Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
612 | 4.063 | \nVentilation panel - 7 (conference hall )\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n9Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n | 1 | Each | |
613 | 4.064 | \nTerrace ventilation panel - 1 & 2 (terrace floor )\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n11Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n | 2 | Each | |
614 | 4.065 | \nMLCP ventilation panel - 1 (GF): Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.\nB) Outgoing :\n10Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 2 | Each | |
615 | 4.066 | \nMLCP ventilation panel - 2 (4f): Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\nB) Outgoing :\n8Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n | 2 | Each | |
616 | 4.067 | \nMain lift panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 630/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.B) \nOutgoing :\n8Nos. 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n630A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n | 1 | Each | |
617 | 4.068 | \nMain pump panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer :\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.\nB) Outgoing :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n5Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n4Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
618 | 4.069 | \nPump panel -2 (rain water storage & harwesting)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 63/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n8Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n63A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
619 | 4.07 | \nPrimary pump panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : \n1Nos 125 Amps 4P Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n9Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
620 | 4.071 | \nSecondary pump panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : \n1Nos 400 Amps 4P Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. -400/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n5Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar : \n400A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
621 | 4.072 | \nUPS outgoing panel-1: Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : \n1Nos 100 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection. \nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set. - of Digital Volt meter (0-10V) with protection fuse for potential circuit connected with neutral busbar to earth bar.\nB) Outgoing :\n6Nos 32 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :100A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
622 | 4.073 | \nUPS outgoing panel-2 : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : \n1Nos 63 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 63/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set. - of Digital Volt meter (0-10V) with protection fuse for potential circuit connected with neutral busbar to earth bar.\nB) Outgoing :\n6 Nos 32 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n | 1 | Each | |
623 | 4.074 | \nEmergency lighting panel-1 : \nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : 1Nos 63 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nB) Outgoing :\n8Nos 32 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n63A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
624 | 4.075 | \nEmergency lighting panel-2 : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : \n1Nos 32 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nB) Outgoing :\n6Nos 16 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n32A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
625 | 4.076 | \nEmergency lighting panel-3 : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : \n1Nos 25 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nB) Outgoing :\n4Nos 16 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n32A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
626 | 4.077 | \nUtility panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : \n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n | 1 | Each | |
627 | 4.078 | LSSB- 1 (ground floor hall - 1,2,3&4)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\nB) Outgoing :\n12Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n | 1 | Each | |
628 | 4.079 | LSSB- 2 (FF HAall-5, CONVENTION HALL, CONFERENCE HALL-1,2&3)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\nB) Outgoing :\n14Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
629 | 4.08 | \nLSSB- 3 (Multi level car parking) : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n9Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 1 | Each | |
630 | 4.081 | \nPSSB- 1 (GF. hall 1,2,3&4) : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n7Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status\n | 1 | Each | |
631 | 4.082 | \nPSSB- 2 (ff hall-5, convention hall, conference hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection. \nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n7Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status\n | 1 | Each | |
632 | 4.083 | \nSub feeder piller - for hall - 1, 2 & 3,4,5 & convention hall\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : 1 & 2\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n10Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n | 16 | Each | |
633 | 4.084 | \nChangeover panel 1250A (indoor type) (ACOS-1,2,3,4,5,6)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : EB & DG\n2 Nos. of 1250 AMPS ACB, 50 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole TM relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:- \n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.. \n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\nb) Busbar :\n1250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\nNote: Electrical & Mechanical interlock to be provied for two incomer and Auto changeover system to be provided for the same.\n\n | 6 | Each | |
634 | 4.085 | \nSFU with enclosure\nDesign, supply, fixing, testing and commissioning of following switch gear with suitable metal enclosure, adopter box to receive suitable rating of incoming and outgoing cable, fixing angle frame, anchor fastner all accossories etc.\n | |||
635 | 4.086 | 100Amps TPN SFU. | 4 | Each | |
636 | 4.087 | 63Amps TPN SFU. | 4 | Nos. | |
637 | 4.088 | 32Amps TPN SFU. | 4 | Nos. | |
638 | 4.089 | 600KVAR CAPACITOR PANEL 1, 2, 3 & 4 FOR 2000KVA TRANSFORMER :\nSupply, Installation, Testing and Commissioning of Medium Voltage floor mounting Cubicle Type Distribution Board suitable for 415 V, 3 Phase, 50 Hz Power Distribution System with the following mounting complete as per specifications attached including necessary control wiring for automatic correction of capacitors ( 16 Stage ) and as specification.\nIncomer:\n1600 AMPS ACB, 50 KA (Ics) AC Motor operated Draw Out ( EDO )Type ,TP&N, Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technical Specifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1 Set of R Y B LED Type Indicating Lamps with HRC fuses and toggle switches .\n1 No 16 Stage Automatic Power factor correction relay for automatic correction of Power factor.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\nBusbars\n1600A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves.\nOUTGOING:\n3 sets of 100 KVAR capacitor bank each comprising of:\ni) 1 no. 400 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 100KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 100 KVAR MPP-H based capacitor\niv) 1 No. 100 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps.\n | 4 | Nos. | |
639 | 4.09 | Continue above\n3 sets of 50 KVAR capacitor bank each comprising of: \ni) 1 no. 200 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 50KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 50 KVAR MPP-H based capacitor\niv) 1 No. 50 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps. \n2 sets of 25 KVAR capacitor bank each comprising of:\ni) 1 no. 100 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 25KVAR 3 Pole Capacitory Duty contactor \niii) 1 No. 25 KVAR MPP-H based capacitor \niv) 1 No. 25 KVAR 7% Detuned Reactor.\n v) 1 Set of ON/ OFF push button and indicating lamps. \n2 sets of 20 KVAR capacitor bank each comprising of:\ni) 1 no. 100 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 20KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 20 KVAR MPP-H based capacitor\niv) 1 No. 20 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps. \n2 sets of 15 KVAR capacitor bank each comprising of:\ni) 1 no. 63 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection\nii) 1 No 15KVAR 3 Pole Capacitory Duty contactor \niii) 1 No. 15 KVAR MPP-H based capacitor | |||
640 | 4.091 | Continue above\n2 sets of 10 KVAR capacitor bank each comprising of:\ni) 1 no. 40 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 10KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 10 KVAR MPP-H based capacitor\niv) 1 No. 10 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps.\n2 sets of 5 KVAR capacitor bank each comprising of:\ni) 1 no. 32 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 5KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 5 KVAR MPP-H based capacitor\niv) 1 No. 5 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps. | |||
641 | 4.092 | Bus duct\nSupply,Erection,Testing and Commissioning of 3200 A TPN 433v, 50HZ, Air cooled insulated LV BUS duct comprising of TPN Aluminium Busbar, necessary right angle bends, Adapter chambers, 25 x 6mm twin copper earth bus for the entire length of the bus duct. The busduct shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc., from 2000KVATransformer secondary side to MV panel 3&4. (As per the detailed Technical Specification enclosed.) OUTDOOR | 18 | Meter | |
642 | 4.093 | Supply,Erection,Testing and Commissioning of 3200 A TPN 433v, 50HZ, Air cooled insulated LV BUS duct comprising of TPN Aluminium Busbar, necessary right angle bends, Adapter chambers, 25 x 6mm twin copper earth bus for the entire length of the bus duct. The busduct shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc., from 2000KVATransformer secondary side to MV panel 3&4. (As per the detailed Technical Specification enclosed.) INDOOR | 42 | Meter | |
643 | 4.094 | Supply,Erection,Testing and Commissioning of 1600 A TPN 433v, 50HZ, Air cooled insulated LV BUS duct comprising of TPN Aluminium Busbar, necessary right angle bends, Adapter chambers, 25 x 6mm twin copper earth bus for the entire length of the bus duct. The busduct shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc., from MV panel 3&4 to APFC panel 600KVAR(As per the detailed Technical Specification enclosed.) INDOOR. | 53 | Meter | |
644 | 4.095 | Supply,Erection,Testing and Commissioning of 3200A Aluminium Flexible expansion joints ( Air cooled insulated ) at the Transformer side and MV panel side with required Standard Accessories etc., complete as required for one set. | 8 | Set | |
645 | 4.096 | Supply,Erection,Testing and Commissioning of 1600A Aluminium Flexible expansion joints ( Air cooled insulated ) at the Transformer side and MV panel side with required Standard Accessories etc., complete as required for one set. | 8 | Set | |
646 | 4.097 | Distribution boards\nMain building LDB & ELDB :\n8W TPN MCB LDB for main endrance & lobby :Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 24 Nos 6 A SP MCB . \n | 1 | Each | |
647 | 4.098 | 6W TPN MCB LDB FOR service area GF, GF mf ahu room, exhibition hall-1,2,3 : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 18 Nos 6 A SP MCB . \n | 8 | Each | |
648 | 4.099 | 4W TPN MCB LDB FOR GF EXHIBITION HALL - 4 : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB . \n | 1 | Each | |
649 | 4.1 | 4W TPN MCB ELDB for ff service area : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB Outgoing : 12 Nos 6 A SP MCB .\n | 5 | Each | |
650 | 4.101 | 12W TPN MCB LDB for ff main endrance & lobby, conference hall-1 : \nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 12 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 36 Nos 6 A SP MCB . \n | 2 | Each | |
651 | 4.102 | 8W TPN MCB ELDB for ff convention hall, conference hall-2 :\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 24 Nos 6 A SP MCB. \n | 2 | Each | |
652 | 4.103 | 6W TPN mcb LDB for ff exhibition hall 5, convention hall & ff ahu room :Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 18 Nos 6 A SP MCB . \n | 3 | Each | |
653 | 4.104 | 4W TPN MCB LDB for ff service area : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB\n | 4 | Each | |
654 | 4.105 | 6W TPN MCB ELDB for GF conference hall: Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 18 Nos 6 A SP MCB. \n | 3 | Each | |
655 | 4.106 | 4W TPN MCB ELDB for ff service area, exhibition hall-5, convention hall :\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB\n. | 3 | Each | |
656 | 4.107 | MLCP LDB & ELDB: \n12W TPN MCB LDB for GF MLCP : \nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 12 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 36 Nos 6 A SP MCB .\n | 1 | Each | |
657 | 4.108 | 8W TPN MCB LDB for ff to 6th fl. MLCP : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 24 Nos 6 A SP MCB. \n | 6 | Each | |
658 | 4.109 | 12W TPN MCB ELDB for MLCP : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 12 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 36 Nos 6 A SP MCB | 1 | Each | |
659 | 4.11 | Utility building LDB & ELDB\n8W TPN MCB LDB for GF & ff Utility building\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 24 Nos 6 A SP MCB. | 2 | Each | |
660 | 4.111 | 4W TPN MCB ELDB for GF & ff Utility building : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB. | 1 | Each | |
661 | 4.112 | Distribution Boards-power distribution board\n4W TPN MCB PDB for GF service area & main lobby : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs with 100mA ELCB\nOutgoing : 12 Nos 16/20 A SP MCB.\n | 5 | Each | |
662 | 4.113 | 4W TPN MCB PDB for 1f service area & main lobby : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs with 100mA ELCB\nOutgoing : 12 Nos 16/20 A SP MCB. \n | 4 | Each | |
663 | 4.114 | 6W TPN MCB PDB for 1f service area & main lobby : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs with 100mA ELCB\nOutgoing : 18 Nos 16/20 A SP MCB . \n | 1 | Each | |
664 | 4.115 | Distribution Boards-UPS : \n8W TPN MCB UPSDB GF service area\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'D' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs \nOutgoing : 24 Nos 16/20 A SP MCB. \n | |||
665 | 4.116 | 6W TPN MCB UPSDB GF service area, GF exhibition hall, ff convention hall, ff conference hall, ff service area \nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'D' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs \nOutgoing : 18 Nos 16/20 A SP MCB. \n | 2 | Each | |
666 | 4.117 | 4W TPN MCB UPSDB GF service area, GF exhibition hall, ff convention hall, ff conference hall, ff service area :\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'D' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs \nOutgoing : 12 Nos 16/20 A SP MCB.\n | 4 | Each | |
667 | 4.118 | Utility building UPS DB :\n4W TPN MCB UPSDB GF utility building :\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'D' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs \nOutgoing : 12 Nos 16/20 A SP MCB. \n | 1 | Each | |
668 | 4.119 | VTPN ventilation distribution boards:\n12W VTPN ventilation db for exhibition hall-1,2,3,4 & 5 :\nFabrication, Supply, Installation, Testing and Commissioning of Vertical type 12 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB \nOutgoing : 12Nos 6/10 A TP MCB. \n | 5 | Each | |
669 | 4.12 | 8W VTPN ventilation db for ff convention hall & conference hall : Fabrication, Supply, Installation, Testing and Commissioning of Vertical type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB \nOutgoing : 8Nos 6/10 A TP MCB. \n | 3 | Each | |
670 | 4.121 | 8W VTPN MCB PDB for utility : Fabrication, Supply, Installation, Testing and Commissioning of Vertical type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB \nOutgoing : 8Nos 6 A TP MCB. \n | 2 | Each | |
671 | 4.122 | VTPN distribution boards : \nLIFT DB : Supplying and fixing of sheet steel, MCB distribution board, 415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. for LIFT DB for Main Hall, MLCP, Restaurant.comprising of the following : \nIncoming : 1No 63 A, 4P MCB \nOutgoing : 1Nos 40 A TP MCB \nOutgoing : 2Nos 16 A TP MCB. \n \n | 15 | Each | |
672 | 4.123 | UPS & Inverter :\nSupply and Erection of 80 KVA UPS Systems with 3-phase input and Three phase output. Maintanance free batteies suitable for backup system should have Half an hour continous rating.The scope includes providing neccesary battery stand , inter connecting cables from UPS battery.The scope also includes providing neccesary by-pass arrangement and all other requirements. The capacity of the battery shall be of 12V DC with a minimum of Suitable ampere hour and as per specification. \n | 1 | Each | |
673 | 4.124 | Supply and Erection of 60 KVA UPS Systems with 3-phase input and Three phase output. Maintanance free batteies suitable for backup system should have Half an hour continous rating.The scope includes providing neccesary battery stand , inter connecting cables from UPS battery.The scope also includes providing neccesary by-pass arrangement and all other requirements. The capacity of the battery shall be of 12V DC with a minimum of Suitable ampere hour and as per specification. \n | 1 | Each | |
674 | 4.125 | Supply and Erection of 50 KVA Inverter Systems with 3-phase input and Three phase output. Maintanance free batteies suitable for backup system should have Half an hours continous rating.The scope includes providing neccesary battery stand , inter connecting cables from Inverter battery.The scope also includes providing neccesary by-pass arrangement and all other requirements. The capacity of the battery shall be of 12V DC with a minimum ofSuitable ampere hour and as per specification. \n \n | 1 | Each | |
675 | 4.126 | Supply and Erection of 15 KVA Inverter Systems with 3-phase input and Three phase output. Maintanance free batteies suitable for backup system should have Half an hours continous rating.The scope includes providing neccesary battery stand , inter connecting cables from Inverter battery.The scope also includes providing neccesary by-pass arrangement and all other requirements. The capacity of the battery shall be of 12V DC with a minimum of Suitable ampere hour and as per specification. \n | 1 | Each | |
676 | 4.127 | LT cabling & end termination :\nSupply and Laying of PVC insulated,XLPE, aluminium conductor, 1.1 KV grade armoured, MV cable of the following sizes as required, generally conforming to IS:7098 Part-I\n | |||
677 | 4.128 | 3 1/2 X 400 sqmm. | 1495 | Metre | |
678 | 4.129 | 3 1/2 X 300 sqmm. | 5021 | Metre | |
679 | 4.13 | 3 1/2 X 240 sqmm. | 4743 | Metre | |
680 | 4.131 | 3 1/2 X 185 sqmm. | 738 | Metre | |
681 | 4.132 | 3 1/2 X 150 sqmm. | 1392 | Metre | |
682 | 4.133 | 3 1/2 X 120 sqmm. | 855 | Metre | |
683 | 4.134 | 3 1/2 X 95 sqmm. | 1465 | Metre | |
684 | 4.135 | 3 1/2 X 70 sqmm. | 1493 | Metre | |
685 | 4.136 | 3 1/2 X 50 sqmm. | 421 | Metre | |
686 | 4.137 | 4 x 25 sqmm. | 5733 | Metre | |
687 | 4.138 | 4 x 16 sqmm . | 4368 | Metre | |
688 | 4.139 | 4 x 10 sqmm . | 154 | Metre | |
689 | 4.14 | 4 x 2.5 sqmm . | 685 | Metre | |
690 | 4.141 | 5Runs of 25Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 10 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA INVERTER GF) and (45 KVA INVERTER 1F)\n | 40 | Metre | |
691 | 4.142 | 5Runs of 10Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 6 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA AND 45KVA UPS UPS O/G DBs)\n | 516 | Metre | |
692 | 4.143 | 5Runs of 6Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 4 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA AND 45KVA UPS UPS O/G DBs)\n | 1307 | Metre | |
693 | 4.144 | TERMINATION :\nSupplying and making end termination with brass Double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV\n | |||
694 | 4.145 | 3 1/2 X 400 sqmm. | 22 | Set | |
695 | 4.146 | 3 1/2 X 300 sqmm. | 168 | Set | |
696 | 4.147 | 3 1/2 X 240 sqmm. | 68 | Set | |
697 | 4.148 | 3 1/2 X 185 sqmm. | 16 | Set | |
698 | 4.149 | 3 1/2 X 150 sqmm. | 18 | Set | |
699 | 4.15 | 3 1/2 X 120 sqmm. | 16 | Set | |
700 | 4.151 | 3 1/2 X 95 sqmm. | 20 | Set | |
701 | 4.152 | 3 1/2 X 70 sqmm. | 16 | Set | |
702 | 4.153 | 3 1/2 X 50 sqmm. | 10 | Set | |
703 | 4.154 | 4 x 25 sqmm. | 66 | Set | |
704 | 4.155 | 4 x 16 sqmm . | 86 | Set | |
705 | 4.156 | 4 x 10 sqmm . | 4 | Set | |
706 | 4.157 | 4 x 2.5 sqmm . | 16 | Set | |
707 | 4.158 | 5Runs of 25Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 10 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA INVERTER GF) and (45 KVA INVERTER 1F) | 4 | Set | |
708 | 4.159 | 5Runs of 10Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 6 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA AND 45KVA UPS UPS O/G DBs) | 12 | Set | |
709 | 4.16 | 5Runs of 6Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 4 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA AND 45KVA UPS UPS O/G DBs) | 20 | Set | |
710 | 4.161 | Perforated cable tray &M.S items : \nSupply, erection of following sizes GI ladder type cable rack system made out of sheet steel folded to required shape with adequate number of supports. (Cable tray support price is not required in this Items).\nThe cable tray shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable tray shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc. The tray shall have suitable cable clamping arrangements etc. | |||
711 | 4.162 | 150 mm Width X 75mm Height X 3mm Thick. | 710 | Metre | |
712 | 4.163 | 300 mm Width X 75mm Height X 3mm Thick. | 795 | Metre | |
713 | 4.164 | 450 mm width X 75mm Height X 3mm Thick. | 650 | Metre | |
714 | 4.165 | 600 mm.width X 75mm Height X 3mm Thick. | 160 | Metre | |
715 | 4.166 | 900 mm width X 100mm Height X 3mm Thick. | 1455 | Metre | |
716 | 4.167 | 1000 mm width X 100mm Height X 3mm Thick. | 690 | Metre | |
717 | 4.168 | Supply and erection of M.S. Material for ladder type cable trays, cable supports, SB, DB's supports, iron embeded in the wall, steel structure in open Area painted with two coats of primer and two coats of enamel paint. Substation to main panel room , ahu room and lighting conduit trays and suspensions of lighting conduit . \n | 16305 | kgs | |
718 | 4.169 | MS chequer plate : \nDesign, cutting, and fixing of 6 mm thick chequered plate with required MS angles for closing around the cable tray shafts and communication shafts. It should be covered with neatly without any gap around the cable tray as per IE Regulation. The gap between cable tray and the chequred plate shall be covered with insulating materials. \n | 120 | sqm | |
719 | 4.17 | Internal wiring for main building : \nWiring for dependent 6 A, 3 Pin Socket outlet with 2 x 1.5 sqmm FRLS PVC insulated Stranded Copper conductor Cable and 1 x 1.5 sqmm FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire, in the lighting switch board, 6 Amps modular type Single Way Switch, 6 A 5 pin, modular type shuttered socket outlet including making connections etc., as per specification \n | 11 | Each | |
720 | 4.171 | \nWiring for Lift Well Light Point and socket oulet with 2 x 1.5 sqmm FRLS PVC insulated Stranded Copper Conductor Cable along with 1 x 1.5 sqmm FRLS PVC insulated Stranded copper conductor cable as earth wire in surface MS conduit including providing and fixing Galvanised / Cadmium plated MS switch box, 2 no 6A Single Way Modular Switch for (controlling light point and socket Outlet) , 1 No 6 A 5 Pin shuttered modular socket outlet with modular switch plate and making necessary connections etc., as per specification (6 Meters shall be considered for Wires & conduit per point.)\n | 80 | Point | |
721 | 4.172 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required. (Raw Power)\n | 58 | Each | |
722 | 4.173 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2/3 pin 5/6 A modular Shuttered socket outlet and 5/6 A modular switch, connections etc. as required. (Raw Power)\n | 2 | Each | |
723 | 4.174 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required for Hand Dryer. (Raw Power)\n | 17 | Each | |
724 | 4.175 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required for Napkin Vending Machine. (Raw Power)\n | 11 | Each | |
725 | 4.176 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2/3 pin 5/6 A modular Shuttered socket outlet and 5/6 A modular switch, connections etc. as required. (UPS Power)\n | 30 | Each | |
726 | 4.177 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and 3 no of fixing 2/3 pin 5/6 A modular Shuttered socket outlet and 1 no of 16 A modular switch, connections etc. as required.(UPS Power)\n | 35 | Each | |
727 | 4.178 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required for (UPS Power)\n | 44 | Each | |
728 | 4.179 | Wiring for power :\nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.\n | |||
729 | 4.18 | 2 x 2.5 sqmm +1 x 1.5 sqmm (E) | 9081 | Metre | |
730 | 4.181 | 2 x 4 sqmm +1 x 2.5 sqmm (E) | 1385 | Metre | |
731 | 4.182 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | |||
732 | 4.183 | 25 mm | 9240 | Metre | |
733 | 4.184 | Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: | |||
734 | 4.185 | 25 mm | 1500 | Metre | |
735 | 4.186 | MS conduit wiring (for lighting): \nWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel\nconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.\n | |||
736 | 4.187 | Group A (One light controlled by one switch - 6mtrs ) | 46 | Each | |
737 | 4.188 | Group B (Two light controlled by one switch - 9mtrs) | 66 | Each | |
738 | 4.189 | Group C (Three light controlled by one switch - 12mtrs) | 132 | Each | |
739 | 4.19 | Run of main wiring for circuit / power / sub main etc :\nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification. | |||
740 | 4.191 | 2 x2.5 sqmm + 1 x 1.5 sqmm (E) | 7208 | Metre | |
741 | 4.192 | Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required: | |||
742 | 4.193 | 25 mm. | 4753 | Metre | |
743 | 4.194 | (LDB to Group controlled Light & ELDB to Group controlled Light) : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification. | |||
744 | 4.195 | 2 x2.5 sqmm + 1 x 1.5 sqmm (E) | 34984 | Metre | |
745 | 4.196 | Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required: | |||
746 | 4.197 | 25 mm. | 22962 | Metre | |
747 | 4.198 | Internal wiring for MLCP : \nWiring for dependent 6 A, 3 Pin Socket outlet with 2 x 1.5 sqmm FRLS PVC insulated Stranded Copper conductor Cable and 1 x 1.5 sqmm FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire, in the lighting switch board, 6 Amps modular type Single Way Switch, 6 A 5 pin, modular type shuttered socket outlet including making connections etc., as per specification.\n | 4 | Each | |
748 | 4.199 | \nWiring for Lift Well Light Point and socket oulet with 2 x 1.5 sqmm FRLS PVC insulated Stranded Copper Conductor Cable along with 1 x 1.5 sqmm FRLS PVC insulated Stranded copper conductor cable as earth wire in surface MS conduit including providing and fixing Galvanised / Cadmium plated MS switch box, 2 no 6A Single Way Modular Switch for (controlling light point and socket Outlet) , 1 No 6 A 5 Pin shuttered modular socket outlet with modular switch plate and making necessary connections etc., as per specification. (3 Meters shall be considered for Wires & conduit per point.)\n \n | 32 | Point | |
749 | 4.2 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required. (Raw Power)\n | 1 | Each | |
750 | 4.201 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no of 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 2 nos of 16 A modular switch, connections etc. as required for BMS (UPS Power)\n | 1 | Each | |
751 | 4.202 | MS CONDUIT WIRING (for Lighting) :\nWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel\nconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | |||
752 | 4.203 | Group A (One light controlled by one switch - 6mtrs ) | 43 | Each | |
753 | 4.204 | Group B (Two light controlled by one switch - 9mtrs) | 5 | Each | |
754 | 4.205 | Group C (Three light controlled by one switch - 12mtrs) | 1 | Each | |
755 | 4.206 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.\n | 4 | Each | |
756 | 4.207 | Run of main wiring for circuit /power / sub main etc : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification. | |||
757 | 4.208 | 2 x2.5 sqmm + 1 x 1.5 sqmm (E) | 6036 | Metre | |
758 | 4.209 | Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required: | |||
759 | 4.21 | 25 mm. | 4435 | Metre | |
760 | 4.211 | (LDB to Group controlled Light &ELDB to Group controlled Light) :\nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification. | |||
761 | 4.212 | 2 x2.5 sqmm + 1 x 1.5 sqmm (E) | 18352 | Metre | |
762 | 4.213 | Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required: | |||
763 | 4.214 | 25 mm. | 10888 | Metre | |
764 | 4.215 | Internal wiring for Utility building :\nSupplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required. (Raw Power) | 41 | Each | |
765 | 4.216 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no of 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 2 nos of 16 A modular switch, connections etc. as required for BMS (UPS Power)\n | 2 | Each | |
766 | 4.217 | Wiring for power : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.\n | |||
767 | 4.218 | 2 x2.5 sqmm + 1 x 1.5 sqmm (E) | 1180 | Metre | |
768 | 4.219 | 2 x 4 sqmm + 1 x 2.5 sqmm (E) | 335 | Metre | |
769 | 4.22 | Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required: | |||
770 | 4.221 | 25 mm. | 1510 | Metre | |
771 | 4.222 | MS conduit wiring (for lighting) :\nWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. \n | |||
772 | 4.223 | Group B (Two light controlled by one switch - 9mtrs) | 41 | Each | |
773 | 4.224 | Group C (Three light controlled by one switch - 12mtrs) | 45 | Each | |
774 | 4.225 | Run of main wiring for circuit /power / sub main etc : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.\n | |||
775 | 4.226 | 2 x2.5 sqmm + 1 x 1.5 sqmm (E) | 3235 | Metre | |
776 | 4.227 | Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required: | |||
777 | 4.228 | 25 mm. | 3015 | Metre | |
778 | 4.229 | (LDB to Group controlled Light &ELDB to Group controlled Light) : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.\n | |||
779 | 4.23 | 2 x2.5 sqmm + 1 x 1.5 sqmm (E) | 213 | Metre | |
780 | 4.231 | Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required: | |||
781 | 4.232 | 25 mm. | 213 | Metre | |
782 | 4.233 | LIGHT FIXTURES FOR MAIN BUILDING:\nSupply, Installation, testing and commissioning of prewired, 40W LED batten fittings, of all types complete with all accessories etc. directly on ceiling / wall, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For Service room, Service corridor, Electrical Room. \nModel No: Bajaj- BLTRU 40W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 223 | Each | |
783 | 4.234 | Supply, Installation, testing and commissioning of prewired, IP65 40W LED batten weather proof fittings, of all types complete with all accessories etc. directly on ceiling / wall, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For AHU room, Electrical Room. \nModel no :BAJAJ-BIPC 40W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 471 | Each | |
784 | 4.235 | Supply, Installation, testing and commissioning of round type high power recess mounting 32W LED down light fixture with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For Lobby & location room. \nModel no:BAJAJ- BCDLR 32 WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 134 | Each | |
785 | 4.236 | Supply, Erection, Testing and commissioning of recessed mounting LED step light fixture with driver (each 5mtrs / 1 driver) on to wall as per site requirement with necessary interconnecting wires & fixing hardwares etc. all complete as required. \nModel no: BAJAJ-75W PROFESSIONAL LED STRIP IP65 WW (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 1774 | Metre | |
786 | 4.237 | Supply, Installation, testing and commissioning of sleek round recess mounting 18W LED down light with all accessories etc.,directly on to the false ceiling (including modifying the false ceiling openings and making good the same) and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For corridor, & Toilet, \nModel no: BAJAJ- BGSLO 18 W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 235 | Each | |
787 | 4.238 | Supply, Installation, testing and commissioning of recessed mounting 120W LED Hige Bay linear light fixture with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For toilet cubicle. \nModel no: BAJAJ-BTHBX 120W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 444 | Each | |
788 | 4.239 | Supply, Installation, testing and commissioning of recess mounting linear with minimalistic shape 72w - 8Ft. LED down light with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. \nModel no: BAJAJ-BRTX 2-40W LED 8F WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 81 | Each | |
789 | 4.24 | Supply, Installation, testing and commissioning of sleek round recess mounting 18W LED down light with all accessories etc.,directly on to the false ceiling (including modifying the false ceiling openings and making good the same) and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For corridor, & Toilet, \nModel no: BAJAJ-BZSLO 18 W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 36 | Each | |
790 | 4.241 | Supply, Installation, Testing and commissioning of recessed mounted white powder coated CRCA sheet LED 600 x 600mm square light fixture directly mounted on the false ceiling including modifying the falseceiling opening and making good the same including stay wire, anchor fastner,interconnection with 2.5 sq. mm, FRLS PVC insulated copper conductor single core cable etc. complete as required. For Exhibition Hall area \nModel no: BAJAJ- BZRSQL 36W GZI WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 218 | Each | |
791 | 4.242 | Supply, Installation, testing and commissioning of 40W recessed down light fixture and accessories etc.,directly fixed on the false ceiling including modifying the false ceiling openings and making good the same and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. \nModel No: PhilipS-RS391 LED30S 5000 PSU (or) Equivalent in Bajaj make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent Model no in Crompton make\n | 88 | Each | |
792 | 4.243 | Supply, Installation, testing and commissioning of 36W recessed down light fixture and accessories etc.,directly fixed on the false ceiling including modifying the false ceiling openings and making good the same and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. \nModel no: BAJAJ-BAJAJ BRWSQ 36W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 113 | Each | |
793 | 4.244 | Supply, Installation, testing and commissioning of 7W recessed down light fixture and accessories etc.,directly fixed on the false ceiling including modifying the false ceiling openings and making good the same and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required\nModel no: BAJAJ-BGSLO Sleek 6W WH RD (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 139 | Each | |
794 | 4.245 | Supply, Installation, testing and commissioning of 3W suspended light fixture and accessories etc.,directly hanging on the true ceiling including wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required.\nModel no:PhilipS-58074 WITH 3W LED BULB (or) Equivalent in Bajaj make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 14 | Each | |
795 | 4.246 | Supply, Installation, testing and commissioning of 36W LED lamp suspended tecorative chandlier light fixture, supporting stay wire from the true ceiling, anchor fastner, and accessories etc.,and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required.\nModel no :PhilipS-36898 treasure ceiling lamp led Gold (or) Equivalent in Bajaj make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make \n | 41 | Each | |
796 | 4.247 | Supply, Installation, testing and commissioning of 80 Led lamp suspended tecorative chandlier light fixture, supporting stay wire from the true ceiling, anchor fastner, and accessories etc.,and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper Conductor, single core cable as required.\nModel no :PhilipS-mimosa 45116 (or) Equivalent in Bajaj make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make | 9 | Each | |
797 | 4.248 | Supply, Installation, testing and commissioning of Die Cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket Bulk head Light fittings with 10W CFL lamp and accessories etc.,directly fixed on the wall and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For Lift Well. \nModel no: BAJAJ- BJDB 10 CFL RF(or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make | 80 | Each | |
798 | 4.249 | LIGHT FIXTURES FOR MLCP:\nSupply, Installation, testing and commissioning of prewired, 40W LED batten fittings, of all types complete with all accessories etc. directly on ceiling / wall, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For car park area.\nModel no: BAJAJ-BAJAJ 14026 BLTRU 40W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 900 | Each | |
799 | 4.25 | Supply, Installation, testing and commissioning of round type high power surface mounting 32W LED down light fixture with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For lift Lobby\nModel no: BAJAJ- BCDLR 32 WH(or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make | 186 | Each | |
800 | 4.251 | Supply, Installation, testing and commissioning of sleek round recess mounting 18W LED down light with all accessories etc.,directly on to the false ceiling (including modifying the false ceiling openings and making good the same) and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For corridor, & Toilet.\nModel no: BAJAJ- BGSLO 18 W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make | 35 | Each | |
801 | 4.252 | Supply, Installation, Testing and commissioning of 1200mm ceiling fan with suspended rod bolt nut with all accessories. Etc. | 4 | Each | |
802 | 4.253 | LIGHT FIXTURES FOR UTILITY BUILDING:\nSupply, Installation, testing and commissioning of prewired, IP65 40W LED batten weather proof fittings, of all types complete with all accessories etc. directly on ceiling / wall, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For AHU room, Electrical Room. \nModel no: BAJAJ-BIPC 40W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 197 | Each | |
803 | 4.254 | Supply, Installation, testing and commissioning of round type high power Surface mounting 32W LED down light fixture with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For Lobby & location room. \nModel no: BAJAJ-BCDLR 32 WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 8 | Each | |
804 | 4.255 | Supply, Installation, testing and commissioning of suspended type 150W Highbay LED down light complete with all accessories etc. directly suspended on true ceiling, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For Stairecase areas. \nModel no: BAJAJ- BGHB 150W WH (or) Equivalent Model no in Philips make (or) Equivalent Model no in wipro make (or) Equivalent Model no in Havells make (or) Equivalent Model no in Crompton make\n | 12 | Each | |
805 | 4.256 | Supply, Installation, testing and commissioning of Die Cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket Bulk head Light fittings with 10W CFL lamp and accessories etc.,directly fixed on the wall and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For terrace area. \nModel no: BAJAJ-BJDB 10 CFL RF (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 28 | Each | |
806 | 4.257 | Supply, Installation, testing and commissioning of LED street light with pressure die cast housin alon with prismatic polycarbonate di user and with secondary optics and IP 65 protection.directly fixed on the wall including wall bracket and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. \nModel no: BAJAJ-BRLEP 25W WH (or) Equivalent Model no in Philips make (or) Equivalent Model no in wipro make (or) Equivalent Model no in Havells make (or) Equivalent Model no in Crompton make | 4 | Each | |
807 | 4.258 | Earthing : \nEarthing with copper earth plate 600X600X3 mm including accessories, and providing masonry enclosure (Chamber size of 1050X1050X700) with fabricated MS Chequre plate of 600X600X6 cover with frame & keel arangement, and watering pipe 3.0 Metre long etc. with charcoal/ coke and salt as required. \nTransformer Neutral Earthing 14 Nos\nDG Neutral Earthing 0 Nos\nUPS 4 Nos: | 18 | NOS. | |
808 | 4.259 | Earthing with C.I. earth pipe 3.0 metre long, 100 mm dia including accessories, and providing masonry enclosure (Chamber size of 1050X1050X700) with fabricated MS Chequre plate of 600X600X6 cover with frame & keel arangement, and watering pipe etc. with charcoal/ coke and salt as required. \nHT VCB Body Earthing 10 Nos \nLT panel Body Earthing 14 Nos \nTransformer Body Earthing 14 Nos\nDG set Body Earthing 0 Nos\nEPABX Earthing 2 Nos\nServer Earthing 2 Nos\nLift Earthing 36 Nos\nChiller Earthing 4 Nos \n | 82 | NOS. | |
809 | 4.26 | Providing and fixing 25mm X 5 mm copper strip on surface or in recess for connections etc. as required. | 10 | Metre | |
810 | 4.261 | Providing and fixing 60 mm x 10 mm copper strip on surface or in recess for connections etc. as required. | 300 | Metre | |
811 | 4.262 | Providing and fixing 25 mm x 6 mm copper strip on surface or in recess for connections etc. as required. | 1908 | Metre | |
812 | 4.263 | Providing and fixing 50 mm x 6 mm GI strip on surface or in recess for connections etc. as required. | 6658 | Metre | |
813 | 4.264 | Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required. | 3316 | Metre | |
814 | 4.265 | Providing and fixing 8 Swg cu wire on surface or in recess for connections etc. as required. | 85 | Metre | |
815 | 4.266 | Providing and fixing 10 Swg cu wire on surface or in recess for connections etc. as required. | 85 | Metre | |
816 | 4.267 | Lightning arrestor : \nSupply, Erection, Testing and Commissioning of lightning arrestor enchanching type designed to attract lightning from a predetermined volume and to safety convey the lightning current to the earth and complaint UL-96 (Under writers labouratories-96) and complete with following principle components. | |||
817 | 4.268 | Air Terminal:\nSupply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) \n : | 3520 | Metre | |
818 | 4.269 | Folding clamp :To hold 8 mm Al conductor at every 1m dist on the top roof without any drilling on roof , Installation can be made through simple fastening system ,mainly used for seaming sheet roof application, Holds good upto \nseaming thickness of upto 20mm . | 2328 | Nos. | |
819 | 4.27 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:\nWith M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance\n | 752 | Nos. | |
820 | 4.271 | Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. \n | 350 | Nos. | |
821 | 4.272 | Providing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . \n | 140 | Nos. | |
822 | 4.273 | Providing of expansion piece with connector: For equalising temperature related length changes.Necessary on conductors length over 20 meters.For round conductor Rd 8/ALU. \n | 101 | Nos. | |
823 | 4.274 | Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ).\n | 202 | Nos. | |
824 | 4.275 | Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC 62305 part-3 16mm rod tapered to 10 mm aluminium rod : \nMeets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) \n4Metre Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. | 4 | Nos. | |
825 | 4.276 | Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC 62305 part-3 16mm rod tapered to 10 mm aluminium rod : \nMeets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) \n 2Metre Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. | 13 | Nos. | |
826 | 4.277 | Accessories : System consist of Fang Fix with base and clamp, on the top air terminal is erected. | 4 | Nos. | |
827 | 4.278 | Accessories : System consist of Fang Fix with base and clamp, on the top air terminal is erected. | 8 | Nos. | |
828 | 4.279 | Down Conductor :\nSupply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185- 305 (IS/IEC 62305) \n | 1135 | Metre | |
829 | 4.28 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:\nWith M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance | 1135 | Nos. | |
830 | 4.281 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:\nWith M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance \n | 40 | Metre | |
831 | 4.282 | Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6.\n | 2 | Nos. | |
832 | 4.283 | Earthing Pit :\nSupply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directlyin ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx:70 micron\ncoating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding. \n | 850 | Metre | |
833 | 4.284 | Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. | 70 | Nos. | |
834 | 4.285 | Providing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts. | 40 | Nos. | |
835 | 4.286 | Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. | 5 | Nos. | |
836 | 4.287 | Supply of CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 | 40 | Metre | |
837 | 4.288 | Providing The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system | 40 | Nos. | |
838 | 4.289 | provided with universal clamp made of SS to connect rod with flat conductor | 40 | Nos. | |
839 | 4.29 | Providing the above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system | 40 | Nos. | |
840 | 4.291 | Street / yard lighting:\nSupply , fixing, testing and commissioning of .8M height Hot dip galvanized poles, with integral control box, MCB and cable termination arrangement with top bracket. \n | 68 | Each | |
841 | 4.292 | Supply , fixing, testing and commissioning of street light EDGE Series of LED street light luminaire | 68 | Each | |
842 | 4.293 | Supply , fixing, testing and commissioning of street light EDGE Series of LED street light luminaire \nModel no :BAJAJ-BRTFG Series of Lights (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 54 | Each | |
843 | 4.294 | Supply , fixing, testing and commissioning of Bollard light luminaire \nModel no: BAJAJ-BGBOL 605 9W LED (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 1 | Each | |
844 | 4.295 | Supply , fixing, testing and commissioning of Recessed Ramp light luminaire \nModel no: Havells-LHESABPBUN6E008 8 W (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n | 70 | Each | |
845 | 4.296 | Supply, Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4Cx25sqmm Aluminium armoured cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requried. | 3350 | Metre | |
846 | 4.297 | Supply, Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4Cx4sqmm copper armoured cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requried. | 2120 | Metre | |
847 | 4.298 | Safety equipments :\nSupply and installing the following items as per local Electrical Inspectorate's requirement. | |||
848 | 4.299 | 12 mm thick rubber mat. | 384 | Sq. Mt. | |
849 | 4.3 | Fire Buckets stand suitable for 4 Nos. fire buckets with Fire Buckets filled with stand.. | 10 | Each | |
850 | 4.301 | First Aid Box with stand. | 10 | Each | |
851 | 4.302 | Shock Treatment Chart in 2 Language (Local Language and English) | 5 | Each | |
852 | 4.303 | Supply & Fixing HT cable route marker with 10cm. x 10cm. 5mm thick G.I.plate with inscription thereon, bolted/ welded to 35mm x 35mm x 6mm angle iron, 60 cm. long and fixing the same in ground as required. | 10 | Each | |
853 | 4.304 | Supply and fixing of 11KV Al Danger Boards of size 12" x 8" both in Tamil and English | 5 | Each | |
854 | 4.305 | Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English | 5 | Each | |
855 | 4.306 | Supply of 11 KV Tested Gloves with Box filled with chalk powder. | 2 | Set | |
856 | 4.307 | Supply and erection of fire extinguisher Co2 4.5 Kg. confirm to IS norms. | 2 | Each | |
857 | 4.308 | TNEB AND CEA APPROVALS :\nCEA : \nPreparation of drawings and submission to the statutory authorities such as Chief Electrical Inspectorate/Central Electricity Authority, obtaining approval from all statutory authorities including energizing the Installation for Electrical Installation and for commissioning the system including arranging inspection and also necessary approval / safety certificate from authorities etc. \nThe necessary statutory fees will be paid by the client against proof of demand.\n | 1 | job | |
858 | 4.309 | Preparation of drawings and submission to the statutory authorities such as obtaining approval from TNEB authorities including energizing the Installation for Electrical Installation and for commissioning the system. \nThe necessary statutory fees will be paid by the client against proof of demand. \n | 1 | job | |
859 | 4.31 | MISCELLANEOUS ITEMS :\nTowards Preparation of Drawings, Getting Approval Arranging Inspection and Obtaining load sanction and from Local EB Authorities inclusive of all incidental charges. | 1 | job | |
860 | 4.311 | Towards Preparation of Drawings, Getting Approval Arranging Inspection and Obtaining Safety Certificate from Central Electricity Authority - Chennai. | 1 | job | |
861 | 4.312 | Preparation of AS BUILT Drawings -3 SET | 1 | job | |
862 | 5 | ACMV WORKS | |||
863 | 5.001 | PLANT ROOM WITH ELECTRICAL WORKS | |||
864 | 5.002 | Supplying, installation, testing and commissioning of minimum capacity of 340 TR and above Air cooled screw chillers,1.25 KW/TR +/- 5% Tolerance at design condition including fans as per AHRI 550/590 standard. temperature: 6 deg C leaving and 13 deg C entering condition, at chennai ambient condition 104deg F and 83 Deg F, vibration Isolator and required adaptor box for cable termination, main disconnect switch, Plant manager integerator (consider provision for 8Nos chillers), required pressure differential sensor,incoming cable adaptor box, flow switch, Flange end coupling for inlet and outlet connection, Black Epoxy coated fins, Condenser fins covered with 12 guage SS316 mesh for mechanical protection. compressor sound jacket using Armasound material required thickness of 75mm thick with 22G Al cladding with suitable vibration isolator / Suitable sound jackets shall be provided to meet the tender conditions. \n(i) Suitable cable entry adaptor box with isolater and weather protection outdoor type panel(IP65)\n(ii) differential pressor sensor\n(iii) Vibration isolator \n(iv) Flow switch\n(v) Compressor sound jocket\n(vi) Plant Manager\n(vii) Flange end connection | 6 | Nos | |
865 | 5.003 | Supplying,installation, testing and commissioning of Endsuction long coupled base mounted for primary pumps with bronze impeller, capacity of 649 US gpm@14m head with suitable insulation and 24g AL cladding.\nSupplying and installation of Suitable Inertia frame with Vibration mounting for the above selection of pumps.RCC M20grade pedestal to be casted as per the drawing.\nSupplying and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) and required capacity of by pass star delta starter ,Cubical type indoor panel with single incommer with Main isolator and disconnect switch for all pumps and indoor type encloser box and required BMS compatable for the above operation-7Nos of working Pumps +1 stand by pumps.\n(i) Supplying and installation of insulation for Pump casing using 30mm thick nitrile rubber insulation with 22G al cladding for the above mentioned pumps\n(ii) Supplying and applying of Enamel paint for pump base and water flow sticker. | 7 | Nos | |
866 | 5.004 | Supplying,installation and commissioning of double suction top discharge, long coupled base mounted for Secondary pumps with bronze impeller, capacity of 1299 Usgpm@28m head,3 Sets of DPT with suitable insulation and 24g AL cladding.\nSupplying and installation of Suitable Inertia frame with Vibration mounting for the above selection of pumps.RCC M20grade pedestal to be casted as per the drawing.\nSupplying and installation for Secondary Pump with Pump logic controller for pump operation and Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) and capacity of by pass star delta starter, Cubical type Indoor panel with single incommer with suitable Main isolator, disconnect for all pumps,encloser box and BMS compatable for the above operation-4Nos of working Pumps +1 stand by pumps.\n(i) Supplying and installation of insulation for Pump casing using 30mm thick nitrile rubber insulation with 22G al cladding for the above mentioned pumps.\n(ii) Supplying and applying of Enamel paint for pump base and water flow sticker.\n(iii) Supplying and installation of 3Nos of DP sensor for pump operation with amplifier and necessary support and copper tubing between dp sensor to chilled water line.\n\n | 5 | Nos | |
867 | 5.005 | InSulated Valves | |||
868 | 5.006 | Supplying,installation and commissioning of NON - Return Valve with dual plate of CI body SS plates Vulcanised NBR sea; flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. | |||
869 | 5.007 | 250 mm dia | 5 | Nos | |
870 | 5.008 | 200 mm dia | 7 | Nos | |
871 | 5.009 | Supplying, installation and commissioning of Metallic bellows suitable for pipes, pressure rating of PN16 | |||
872 | 5.01 | 250 mm dia | 10 | Nos | |
873 | 5.011 | 200 mm dia | 26 | Nos | |
874 | 5.012 | Supplying, installation and commissioning of Suction Guide suitable for pipes with pressure rating of PN16-with insulation and 24g AL cladding | |||
875 | 5.013 | 250 mm dia | 5 | Nos | |
876 | 5.014 | 200 mm dia | 7 | Nos | |
877 | 5.015 | Motorized Butterfly Valves with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating ,conforming to BS 5155, IS 13095, with IP-55 actuator as specified. | |||
878 | 5.016 | 250 mm dia | 7 | Nos | |
879 | 5.017 | 200 mm dia | 13 | Nos | |
880 | 5.018 | Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. | |||
881 | 5.019 | 450 mm dia | 2 | Nos | |
882 | 5.02 | 400 mm dia | 1 | Nos | |
883 | 5.021 | 350 mm dia | 2 | Nos | |
884 | 5.022 | 300 mm dia | 4 | Nos | |
885 | 5.023 | 250 mm dia | 5 | Nos | |
886 | 5.024 | 200 mm dia | 13 | Nos | |
887 | 5.025 | Supplying,installation of pressurised closed expansion tank with stand by motor and bms compatible -capacity of 3000 lit. for water. 100mm thick rigid puff insulation with 20G GI cladding with float valve arrangement | 1 | Nos | |
888 | 5.026 | Supplying and installation of ms angle support for plant room. | 8000 | kg | |
889 | 5.027 | Supplying and installation of 12mm thick Ms Checkered plate for shaft/chiller service platform closings etc. | 2280 | kg | |
890 | 5.028 | Supplying,Laying and commissioing of PVC insulated, copper conductor FRLS 1.1kv grade, Armoured copper cable | |||
891 | 5.029 | 1C x 240 sqmm xlpe | 295 | Rmt | |
892 | 5.03 | 4C X70 sqmm xlpe | 235 | Rmt | |
893 | 5.031 | 4c X35 sqmm xlpe | 4200 | Rmt | |
894 | 5.032 | 4C x 16sqmm xlpe | 2480 | Rmt | |
895 | 5.033 | 4C x 10sqmm xlpe | 1890 | Rmt | |
896 | 5.034 | 4C x 6sqmm xlpe | 3420 | Rmt | |
897 | 5.035 | 4C x 4sqmm xlpe | 2340 | Rmt | |
898 | 5.036 | 4C x 2.5sqmm xlpe | 3330 | Rmt | |
899 | 5.037 | 4c x 1.5sqmm | 3060 | Rmt | |
900 | 5.038 | Screened cable 4c x 1.5sqmm | 2100 | Rmt | |
901 | 5.039 | Supplying and Installation of cable end termination with Double brass compression gland and Copper lugs for the following sizes of PVC Insulated XLPE armoured conductor cable of 1.1KV grade complete as required.. | |||
902 | 5.04 | 1C x 240 sqmm xlpe | 102 | Nos | |
903 | 5.041 | 4C X70 sqmm xlpe | 240 | Nos | |
904 | 5.042 | 4c X35 sqmm xlpe | 190 | Nos | |
905 | 5.043 | 4C x 16sqmm xlpe | 320 | Nos | |
906 | 5.044 | 4C x 10sqmm xlpe | 390 | Nos | |
907 | 5.045 | 4c x 2.5sqmm | 420 | Nos | |
908 | 5.046 | 4c x1.5sqmm | 20 | Nos | |
909 | 5.047 | Supplying and installation of Copper earth plate | |||
910 | 5.048 | 25 x3 mm x 2 run | 2800 | Rmt | |
911 | 5.049 | Supplying and installation of following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. | |||
912 | 5.05 | 600mm width x 100mm height x 3mm thickness | 632 | Rmt | |
913 | 5.051 | 450mm width x 100mm height x 3mm thickness | 298 | Rmt | |
914 | 5.052 | 300mm width x 100mm height x 3mm thickness | 102 | Rmt | |
915 | 5.053 | 225mm width x 100mm height x 3mm thickness | 400 | Rmt | |
916 | 5.054 | 150mm width x 100mm height x 3mm thickness | 540 | Rmt | |
917 | 5.055 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required | 180 | Nos | |
918 | 5.056 | Providing & fixing in position the mercury in glass industrial type thermometers. | 180 | Nos | |
919 | 5.057 | Supplying and installation of 25mm Ball valves with flange end, pressure rating PN 16 with insulation and 24g AL cladding | 103 | Nos | |
920 | 5.058 | Supplying and installation of Auto air vent size 25mm dia with 9 Rmt 20mm copper pipe. | 125 | Nos | |
921 | 5.059 | Supplying,installation,testing and commissioning of Electromagnetic Descaler for Chilled water flow suitable capacity of 500 mm dia. | 1 | Nos | |
922 | 5.06 | Supplying,installation,testing and commissioning of Centrifugal, Side Stream Filter for Chilled water, 500mm dia- 9600 gpm. | 1 | Nos | |
923 | 5.061 | Supplying, installation and commissioning of trible duty valves for pumps, pressure rating of PN16 -with insulation and 24g AL cladding | |||
924 | 5.062 | 450 mm dia | 4 | Nos | |
925 | 5.063 | 400 mm dia | 3 | Nos | |
926 | 5.064 | 250 mm dia | 5 | Nos | |
927 | 5.065 | 200 mm dia | 13 | Nos | |
928 | 5.066 | Supply, installation and commissioning of following nominal sizes of chilled water piping (with necessary clamps, vibration isolators and fitting but excluding valves, stainers, gauges etc.)duly insulated with fire retardant quality expanded polystrene moulded pipe section of densidy 20kg/cu.m after a thick coat of cold setting adhestive (CPRX compound) wraping with 500g polythene fced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date)at joints repairing of damage to building etc. as per specifications and as required complete in all respect.\nNote :- The pipes of sizes 150mm & below shall be M.S 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from mnimum 6.35 mm thick M.S sheet for pipes upto 350mm dia. and minimum 7mm thick MS sheet for pipes of 400mm dia and above. 75mm Insulation for pipe above 150mm to 650mm and 50 mm for pipe\nbelow 150mm. | |||
929 | 5.067 | 500mm dia | 420 | Rmt | |
930 | 5.068 | 450mm dia | 90 | Rmt | |
931 | 5.069 | 400mm dia | 85 | Rmt | |
932 | 5.07 | 300mm dia | 90 | Rmt | |
933 | 5.071 | Supply,installation and commissioning of Butterfly value with C I body ss disc. Nitrille rubber seal & o-Ring PN 16 pressure rating for chilled water/hot heater circulation as specified. | |||
934 | 5.072 | 500 mm dia | 1 | Nos | |
935 | 5.073 | 450 mm dia | 1 | Nos | |
936 | 5.074 | 400 mm dia | 1 | Nos | |
937 | 5.075 | 350 mm dia | 2 | Nos | |
938 | 5.076 | Air Handling Units | |||
939 | 5.077 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density, inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 57 TR- 30000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch,enclosed box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n | 10 | Nos | |
940 | 5.078 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density, inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 50 TR- 30000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal.\nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages.\nd) Charges for Air balancing works for the above with low side.\ne) charges for Water balancing for the above mentioned. \nf) Supplying and installation charges for fire rated canvas connection for the above.\n | 3 | Nos | |
941 | 5.079 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density, inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thich nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 50 TR- 25000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above | 32 | Nos | |
942 | 5.08 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 39 TR- 21000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s.Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n | 2 | Nos | |
943 | 5.081 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 30 TR- 16000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n | 8 | Nos | |
944 | 5.082 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/Cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 30 TR- 14000CFM, 80mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n | 5 | Nos | |
945 | 5.083 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above- Capacity of 20 TR- 10000CFM, 70mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n | 1 | Nos | |
946 | 5.084 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commisoing filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above- Capacity of 20 TR- 9500CFM, 65mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconect switch encloser box and required BMS compatable for the above operation\nb) Supplying and instaltion of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and instaltion of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and instaltion charges for fire rated canvas conection for the above\n | 2 | Nos | |
947 | 5.085 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commisoing filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above- Capacity of 16 TR- 8000CFM, 65mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconect switch encloser box and required BMS compatable for the above operation\nb) Supplying and instaltion of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and instaltion of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and instaltion charges for fire rated canvas conection for the above\n | 1 | Nos | |
948 | 5.086 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commisoing filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above-Capacity of 16 TR- 7000CFM, 50mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconect switch encloser box and required BMS compatable for the above operation\nb) Supplying and instaltion of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and instaltion of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and instaltion charges for fire rated canvas conection for the above\n | 2 | Nos | |
949 | 5.087 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commisoing filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above- Capacity of 12TR- 6500CFM, 50mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconect switch encloser box and required BMS compatable for the above operation\nb) Supplying and instaltion of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and instaltion of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and instaltion charges for fire rated canvas conection for the above\n | 1 | Nos | |
950 | 5.088 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 6 TR- 2500CFM, 50mm total Static and fan outlet velocity shall be less than 9m/s.Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nc) Charges for Air balancing works for the above with low side \nd) charges for Water balancing for the above mentioned \ne) Supplying and installation charges for fire rated canvas connection for the above\n | 2 | Nos | |
951 | 5.089 | Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 4 TR- 2700CFM, 50mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nc) Charges for Air balancing works for the above with low side \nd) charges for Water balancing for the above mentioned \ne) Supplying and installation charges for fire rated canvas connection for the above\n | 1 | Nos | |
952 | 5.09 | HEAT RECOVERY UNITS | |||
953 | 5.091 | Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick . Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, 450 mm depth enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 10300cfm@ external static 80mm and exhast air fan shall be 8755cfm, 76% of efficieny for sensibel and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides, Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch,enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhaust and Supply air fan suitable vfd and b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n\n | 2 | Nos | |
954 | 5.092 | Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick . Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, with enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 8900cfm@ external static 80mm and exhast air fan shall be 7565cfm, 76% of efficieny for sensibel and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides.Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhast and Supply air fan suitable vfd b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n | 8 | Nos | |
955 | 5.093 | Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick . Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, with enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 14700cfm@ external static 80mm and exhast air fan shall be 12495cfm, 76% of efficieny for sensibel and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides.Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhaust and Supplying air fan suitable vfd b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n | 2 | Nos | |
956 | 5.094 | Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick. Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, with enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 4700cfm@ external static 80mm and exhast air fan shall be 3995cfm, 75% of efficieny for sensibel and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhaust and Supplying air fan suitable vfd b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n | 1 | Nos | |
957 | 5.095 | Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick . Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, with enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 8200cfm@ external static 80mm and exhast air fan shall be 6970cfm, 75% of efficiency for sensible and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhaust and Supply air fan suitable vfd b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supplying and installation charges for fire rated canvas connection for the above\n\n | 1 | Nos | |
958 | 5.096 | Fan coil Units | |||
959 | 5.097 | 1.5 TR Capacity - 850 CFM 25mm Static,complete with isolation valve,Strainer,modulation type valve with actuators, inclusive of 30mm thick nitrlie rubber insulation and 26g Al cladding and 22G SS drain tray with 25mm nipple provision for drain connection , 5 m copper 4 core flexible wire with flexible Gi house with plug top | 1 | Nos | |
960 | 5.098 | 2.0 TR Capacity - 900 CFM 25mm Static,complete with isolation valve, Stainer,modulation type valve with actuators, inclusive of 30mm thick nitrlie rubber insulation and 26g Al cladding and 22G SS drain tray with 25mm nipple provision for drain connection , 5 m copper 4 core flexible wire with flexible Gi house with plug top | 1 | Nos | |
961 | 5.099 | 2.5 TR Capacity - 1000CFM 25mm Static,complete with isolation valve, strainer, modulation type valve with actuators, inclusive of 30mm thick nitrlie rubber insulation and 26g Al cladding and 22G SS drain tray with 25mm nipple provision for drain connection , 5 m copper 4 core flexible wire with flexible Gi house with plug top | 3 | Nos | |
962 | 5.1 | PIPING | |||
963 | 5.101 | Supply, installation and commissioning of following nominal sizes of chilled water piping (with necessary clamps, vibration isolators and fitting but excluding valves, stainers, gauges etc.)duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20kg/cum after thick coat of cold setting adhestive (CPRX compound) wraping with 500gauge polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date)at joints repairing of damage to building etc. as per specifications and as required complete in all respect.\nNote :- The pipes of sizes 150mm & below shall be M.S 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from mnimum 6.35 mm thick M.S sheet for pipes upto 350mm dia. and from minimum 7mm thick MS sheet for pipes of 400mm dia and above.\n75mm Insulation for pipe above 150mm to 650mm and 50 mm for pipe below 150mm. | |||
964 | 5.102 | 350 mm dia | 132 | Rmt | |
965 | 5.103 | 300 mm dia | 350 | Rmt | |
966 | 5.104 | 250 mm dia | 1356 | Rmt | |
967 | 5.105 | 200 mm dia | 456 | Rmt | |
968 | 5.106 | 150 mm dia | 672 | Rmt | |
969 | 5.107 | 125 mm dia | 154 | Rmt | |
970 | 5.108 | 100 mm dia | 940 | Rmt | |
971 | 5.109 | 80 mm dia | 360 | Rmt | |
972 | 5.11 | 65 mm dia | 106 | Rmt | |
973 | 5.111 | 50 mm dia | 150 | Rmt | |
974 | 5.112 | 40 mm dia | 30 | Rmt | |
975 | 5.113 | 32 mm dia | 120 | Rmt | |
976 | 5.114 | 25 mm dia | 312 | Rmt | |
977 | 5.115 | Supply and installation of ms Class C pipe with Insulated Condensate Drain pipe-25mm thick rigid puff density 48 Kg/m3, 24G AL. cladding | |||
978 | 5.116 | 65 mm dia | 820 | Rmt | |
979 | 5.117 | 50 mm dia | 900 | Rmt | |
980 | 5.118 | 40 mm dia | 740 | Rmt | |
981 | 5.119 | 32 mm dia | 390 | Rmt | |
982 | 5.12 | 25 mm dia | 170 | Rmt | |
983 | 5.121 | Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected outside pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. | |||
984 | 5.122 | 350 mm dia | 2 | Nos | |
985 | 5.123 | 300 mm dia | 2 | Nos | |
986 | 5.124 | 250 mm dia | 2 | Nos | |
987 | 5.125 | 200 mm dia | 2 | Nos | |
988 | 5.126 | 150 mm dia | 2 | Nos | |
989 | 5.127 | 125 mm dia | 2 | Nos | |
990 | 5.128 | Supply, installation and commissioning of Butterfly Valve with extended stem of 100mm length, pressure rating of PN16, SS wafer/stem with insulation and 24g Al cladding | |||
991 | 5.129 | 250 mm dia | 6 | Nos | |
992 | 5.13 | 200 mm dia | 4 | Nos | |
993 | 5.131 | 150 mm dia | 6 | Nos | |
994 | 5.132 | 125 mm dia | 4 | Nos | |
995 | 5.133 | 100 mm dia | 70 | Nos | |
996 | 5.134 | 80 mm dia | 36 | Nos | |
997 | 5.135 | 65 mm dia | 12 | Nos | |
998 | 5.136 | 50 mm dia | 2 | Nos | |
999 | 5.137 | 40 mm dia | 6 | Nos | |
1000 | 5.138 | 32 mm dia | 4 | Nos | |
1001 | 5.139 | Supply, Installation, Testing and Commissioning of following sizes electronic, self balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 10V DC and 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. | |||
1002 | 5.14 | 100 mm dia | 35 | Nos | |
1003 | 5.141 | 80 mm dia | 18 | Nos | |
1004 | 5.142 | 65 mm dia | 6 | Nos | |
1005 | 5.143 | 50 mm dia | 1 | Nos | |
1006 | 5.144 | 40 mm dia | 1 | Nos | |
1007 | 5.145 | 32 mm dia | 12 | Nos | |
1008 | 5.146 | 25 mm dia | 3 | Nos | |
1009 | 5.147 | Supply,installation and commissioning of Ball valve with flange end, pressure rating of PN25-with insulation and 24G al cladding | |||
1010 | 5.148 | 32 mm dia | 40 | Nos | |
1011 | 5.149 | 25 mm dia | 50 | Nos | |
1012 | 5.15 | Supply,installation and commissioning of Ball valve with strainer flange end, pressure rating of PN25-with insulation and 24G al cladding | |||
1013 | 5.151 | 32 mm dia | 10 | Nos | |
1014 | 5.152 | 25 mm dia | 5 | Nos | |
1015 | 5.153 | Supply,installation and commissioning of Y Stainer of Ductile C I body ends with stainless steel strainer for chiller / hot water circulation including insulation as specified. | |||
1016 | 5.154 | 100 mm dia | 35 | Nos | |
1017 | 5.155 | 80 mm dia | 18 | Nos | |
1018 | 5.156 | 65 mm dia | 6 | Nos | |
1019 | 5.157 | 50 mm dia | 1 | Nos | |
1020 | 5.158 | 40 mm dia | 1 | Nos | |
1021 | 5.159 | 32 mm dia | 12 | Nos | |
1022 | 5.16 | 25 mm dia | 3 | Nos | |
1023 | 5.161 | Supply, installation and commissioning of BTU meter with ultrosonic type, required sensor, display unit ,pressure rating of PN16, SS wafer/stem with insulation and 24g AL cladding,suitable for 230v power | |||
1024 | 5.162 | 100 mm dia | 35 | Nos | |
1025 | 5.163 | 80 mm dia | 18 | Nos | |
1026 | 5.164 | 65 mm dia | 6 | Nos | |
1027 | 5.165 | 50 mm dia | 1 | Nos | |
1028 | 5.166 | 40 mm dia | 1 | Nos | |
1029 | 5.167 | 32 mm dia | 12 | Nos | |
1030 | 5.168 | 25 mm dia | 8 | Nos | |
1031 | 5.169 | Supply and installation of test point of size 25mm dia | 134 | Nos | |
1032 | 5.17 | LOW SIDE WORKS | |||
1033 | 5.171 | Supply, installation,balancing and commissioning of factory fabricated(180GSM) GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,splitter damper, vanes,hangers, supports etc. as per approved drawings and specifications of following complete as required. | |||
1034 | 5.172 | 18G (1.25mm) | 11895 | Sqmt | |
1035 | 5.173 | 20G (1.00mm) | 1423 | Sqmt | |
1036 | 5.174 | 22G (0.80mm) | 11002 | Sqmt | |
1037 | 5.175 | 24G (0.63mm) | 25783 | Sqmt | |
1038 | 5.176 | Supply & fixing of powder coated extruded aluminium Supply air grilles | 459 | Sqmt | |
1039 | 5.177 | Supply and installation of Drum type diffuser with collar control damper with heavy duty type aluminium anodized profile materials. | 257 | Sqmt | |
1040 | 5.178 | Supply and installation of al.powdered coated round diffusers with damper (450 to 600 ext dia) | 149 | Nos | |
1041 | 5.179 | Supply, installation, testing and commisioning of GI voulme control damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, | 459 | Sqmt | |
1042 | 5.18 | Supply and installation of (S/R )adjustable vane Swril type diffuser size 600mm x 600 mm, Handling of air volume of 600cfm to 650cfm | 80 | Nos | |
1043 | 5.181 | Supply, fixing,testing and commissioning of the dampers in suply air duct / main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorised and spring return so as to close the damper in the event of power failure auromatically and open the same in case of power being restrored. the spring return action shall be inbuilt machanism and not externally mounted.The damper shall alos be closed in the event of fire signal complete as required and as per specification. | 87 | Sqmt | |
1044 | 5.182 | Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. | |||
1045 | 5.183 | 300 mm dia | 210 | Sqmt | |
1046 | 5.184 | 250 mm dia | 179 | Sqmt | |
1047 | 5.185 | 200/150/100 mm dia | 193 | Sqmt | |
1048 | 5.186 | Supply and installation of Plenum boxes 24G with inside 6mm thick nitrile rubber insulation (525x525x450 mm) | 212 | Nos | |
1049 | 5.187 | Supply and installation of Butterfly dampers dia 300 mm | 210 | Nos | |
1050 | 5.188 | Supply and installation of Butterfly dampers dia 250 mm | 179 | Nos | |
1051 | 5.189 | Supply and installation of Butterfly dampers dia 100/150/200 mm | 193 | Nos | |
1052 | 5.19 | Supply and installation of toilet exhast disc valves (size 100 to 150mm ) with control damper | 1457 | Nos | |
1053 | 5.191 | Supply and fixing of following thickness duly laminated aluminium foil of mat finish closed cell nitrille rubber (class "O")insulation on existing duct after applyinh suitable adhesive for nitrille rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrille rubber tape insulation complete as per specifications and as required. | |||
1054 | 5.192 | 25mm | 26986 | Sqmt | |
1055 | 5.193 | 19mm | 14425 | Sqmt | |
1056 | 5.194 | Supply, installation and commissioning of Duct Accoustic (Nitrile rubber base, Open cell material 25mm thick, Thermal conductivity 0.047w/m.k@20deg C, excellent absorption, 99.9% reduction of bacterial growth, class1 fire performance, with a density of 140-180Kg/cubicmeter) | 4047 | Sqmt | |
1057 | 5.195 | Supply and installation of Non return air dampers low leakage type with spring loaded | 22 | Sqmt | |
1058 | 5.196 | Supply, installation of gripple hanger system for ducts instalation -hanging weight 60 -120kg | 5315 | Nos | |
1059 | 5.197 | Supply and installation of drain pump (1.5m lift of water)with motor for FCUs and CSUs, required 5Rmt cable between motor and isolater with 5amps plu top | 5 | Nos | |
1060 | 5.198 | Supply, installation, testing and commissioning of Double skin plennum section of 50mm thick puff 48 kg/cum density , inner and outer skin shall be 0.64mm thick with required GI Base , inner shall be 25mm thick armosound accoustic insulation to be attached suitable suitable | 370 | Sqmt | |
1061 | 5.199 | VENTILATION WORKS | |||
1062 | 5.2 | Supply, installation, testing and commissioning of Double skin cabinet type liftwell pressurization ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 50000cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n | 2 | Nos | |
1063 | 5.201 | Supply, installation, testing and commissioning of Double skin cabinet type liftwell pressurization ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 42500 cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n | 4 | Nos | |
1064 | 5.202 | Supply, installation, testing and commissioning of Double skin cabinet type liftwell/Stair pressurization ,inner skin and outer skin shallbe 0.64 mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 23500cfm-36 mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n\n | 2 | Nos | |
1065 | 5.203 | Supply, installation, testing and commissioning of Double skin cabinet type liftwell pressurization ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 19000cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n\n | 1 | Nos | |
1066 | 5.204 | Supply, installation, testing and commissioning of Double skin cabinet type Fresh /exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 16150cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n\n | 1 | Nos | |
1067 | 5.205 | Supply, installation, testing and commissioning of Double skin cabinet type Fresh air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 11500cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n | 14 | Nos | |
1068 | 5.206 | Supply, installation, testing and commissioning of Double skin cabinet type fresh/exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter , limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 6200cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n | 8 | Nos | |
1069 | 5.207 | Supply, installation, testing and commissioning of Double skin cabinet type Fresh air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 5800cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 5 | Nos | |
1070 | 5.208 | Supply, installation, testing and commissioning of Double skin cabinet type exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 5300cfm-30mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 8 | Nos | |
1071 | 5.209 | Supply, installation, testing and commissioning of Double skin cabinet type Fresh air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 4900cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 5 | Nos | |
1072 | 5.21 | Supply, installation, testing and commissioning of SISW exhast air fan,Aerofoil backward curve fan with high eff. motor of IE2 type,outlet damper needs to be provoided, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 50000cfm-105mm total static \na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 1 | Nos | |
1073 | 5.211 | Supply, installation, testing and commissioning of Double skin cabinet type Fresh/exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 4700cfm-30mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 7 | Nos | |
1074 | 5.212 | Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 4300cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 24 | Nos | |
1075 | 5.213 | Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 3600cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 12 | Nos | |
1076 | 5.214 | Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 2800cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 3 | Nos | |
1077 | 5.215 | Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 2500cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 5 | Nos | |
1078 | 5.216 | Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 2200cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 6 | Nos | |
1079 | 5.217 | Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 1500cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above | 3 | Nos | |
1080 | 5.218 | Supply, installation, testing and commissioning of Inline fans, The casing shall be single skin 0.64mm thick, internally acoustically lined and constructed of galvanized steel sheet. The fan shall be forward curve impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 3 phase 50 cycles AC Supplying. Low sound level exceeding Nost more than 39 dBA at three meter distance. All necessary standard accessories like flexible connectors,vibration isolaters etc.- 1000 cfm -25mm of total static\na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above | 10 | Nos | |
1081 | 5.219 | Supply, installation, testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 1200cfm-25mm total static \na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above | 2 | Nos | |
1082 | 5.22 | Supply, installation, testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 1000cfm-25mm total static \na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above | 8 | Lot | |
1083 | 5.221 | Supply, installation, testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 800cfm-25mm total static\na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above | 1 | Lot | |
1084 | 5.222 | Supply, installation,testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 300cfm-25mm total static\na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above | 1 | Lot | |
1085 | 5.223 | Supply, installation, testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe .8mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 76000cfm-50mm total static\na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above | 7 | Lot | |
1086 | 5.224 | CAR PARK/FUME EXTRACT VENTILATION SYSTEM | |||
1087 | 5.225 | System shall be based on current NBC standards and meet the requirements of local Fire Authority \nSupply and installation of Exhaust air Vane axial fan 17000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination, \na) Supply and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supply and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supply and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supply and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper, GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supply and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supply and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supply and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supply and installation for Emergency Push button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing\n\n | 14 | Nos | |
1088 | 5.226 | Supply and installation of Exhaust air Vane axial fan 34000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination,\na) Supply and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supply and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supply and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supply and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper , GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supply and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supply and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supply and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supply and installation for Emergency Push button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing \n\n | 36 | Nos | |
1089 | 5.227 | Supply and installation of Exhaust air Vane axial fan 32000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination, \na) Supplying and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supplying and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supplying and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supplying and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper , GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supplying and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supplying and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supplying and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supplying and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supplying and installation for Emergency Pusb button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing \n\n | 2 | Nos | |
1090 | 5.228 | Supply and installation of Exhaust air Vane axial fan 27000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination, \na) Supply and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supply and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supply and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supply and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper, GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supply and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supply and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supply and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supply and installation for Emergency Push button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing \n\n | 3 | Nos | |
1091 | 5.229 | Supply and installation of Exhaust air Vane axial fan 90000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination, \na) Supply and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supply and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supply and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supply and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper, GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supply and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supply and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supply and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supply and installation for Emergency Push button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing \n | 6 | Nos | |
1092 | 5.23 | Supply and fixing of following 25mm sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | 8320 | Rmt | |
1093 | 5.231 | Supply and installation of Push button station for emergency stop | 192 | Nos | |
1094 | 5.232 | Supplying and installation of Exhaust Air Grilles/Louvers with flange shall be 40mm wide heavy duty type | 191 | Sqmt | |
1095 | 6 | FIRE FIGHTING WORKS PUMP HOUSE | |||
1096 | 6.001 | Supplying, Installation, Testing and Commissioning of 171 Cum/hr. TEFC type electrically driven horizontal centrifugal (End Suction type) Main pumpset with class F insulation & IP 55 protection for Fire Hydrant & Sprinkler system at 100 Mtrs. Head and 2900 rpm with all necessary accessories like providing and fixing bronze impeller, stainless steel shaft coupling, coupling guard, mechanical seal, Cast Iron pump casing & baseplate for pump, fabricated mild steel channel with foundation bolts, etc Pump shall have electrical motor of adequate H.P. suitable for electric Supplying of 415V, 50 Hz, 3Ph Star/Delta Starter connection. | 2 | Sets | |
1097 | 6.002 | Supplying, Installation, Testing and Commissioning of 171Cum/hr. diesel engine driven horizontal centrifugal pumpset (End Suction type) Standby pumpset for Fire Hydrant & Sprinkler system at 100 Mtrs. Head & 1800/2100 rpm with all necessary accessories like providing & fixing bronze impeller, stainless steel shaft, Direct coupling, Mechanical seal, Cast Iron pump casing, base plate for pump, fabricated mild steel channel with foundation bolts etc., It includes providing & fixing fuel 200 litres elevated tank with Supplying and return piping, steel supports for diesel tank, valves, fill and vent lines, flexible connections, 2 sets of battery with charging arrangement, alternator & instrument panel suitable for 24 volt DC including starting switches to be connected to control panel of diesel engine and exhaust silencer including necessary pipework and lagging, etc., Batteries, cooling water line for engine with required pipes, valves, fittings, exhaust fittings, etc., | 1 | Set | |
1098 | 6.003 | Supplying, Installation, Testing and Commissioning of 10.8 Cum/hr. TEFC type Vertical In line pump Jockey pumpset with class F inulation & IP 55 protection for Fire Hydrant & Sprinkler system at 100 Mtrs. Head and 2900 rpm with all necessary accessories like providing and fixing SS304 impeller & stage casing, stainless steel shaft, Mechanical seal, coupling guard & CI base for pump, fabricated mild steel channel with foundation bolts, etc. Pump shall have electrical motor of adequate H.P. suitable for electric Supplying of 415V, 50 Hz, 3Ph for DOL Starter connection. | 2 | Set | |
1099 | 6.004 | Supplying, Installation, Testing and Commissioning of C.I. body, EPDM seat, SGI disc, Butterfly valve PN 16, SGI Hand lever operated, wafer ends conforming to BS:5155. | |||
1100 | 6.005 | 300 mm NB. | 2 | Nos. | |
1101 | 6.006 | 200 mm NB. | 6 | Nos. | |
1102 | 6.007 | 150 mm NB. | 6 | Nos. | |
1103 | 6.008 | 80 mm NB. | 6 | Nos. | |
1104 | 6.009 | Supplying, Installation, Testing and Commissioning of Flanged Ball type Non return Valve PN 16, SGI body & reinforced rubber coat ball, conforming to IS 5312, Vertical installation. | |||
1105 | 6.01 | 300 mm NB | 1 | Nos. | |
1106 | 6.011 | 200 mm NB. | 4 | Nos. | |
1107 | 6.012 | 80 mm NB | 1 | Nos. | |
1108 | 6.013 | Supplying, Installation, Testing and Commissioning of gunmetal gate valve having screwed ends as per specification with necessary flanges, nut, bolts & washers, etc. complete as required conforming to IS 778. | |||
1109 | 6.014 | 32 mm NB Gate valve | 4 | Nos. | |
1110 | 6.015 | 25 mm NB Gate valve | 64 | Nos. | |
1111 | 6.016 | Supplying, Installation, Testing and Commissioning of C.I body & cover, SS304 strainer & carbon steel bolts & nuts. - Pot type Strainer. | |||
1112 | 6.017 | 300 mm NB. | 1 | Nos. | |
1113 | 6.018 | 250 mm NB. | 3 | Nos. | |
1114 | 6.019 | 100 mm NB. | 1 | Nos. | |
1115 | 6.02 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : | |||
1116 | 6.021 | 300 mm NB Pipes. | 27 | RMT | |
1117 | 6.022 | 200 mm NB Pipes. | 57 | RMT | |
1118 | 6.023 | 80 mm NB Pipes. | 46 | RMT | |
1119 | 6.024 | 25 mm NB Pipes. | 52 | RMT | |
1120 | 6.025 | Supplying, Installation, Testing and Commissioning of Dial type pressure guage with 150mm dial and a range of 0-10 Kg./sq.cm. together with siphon and pet cock. | 6 | Nos. | |
1121 | 6.026 | Supplying, Installation, Testing and Commissioning of pressure switches together with accessories. | 4 | Nos. | |
1122 | 6.027 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. | 1 | Set. | |
1123 | 6.028 | Supplying, Installation, Testing and Commissioning of Sheet steel fabricated cubicle type, MCC with Star-Delta starter IP55 panel for the electrical motor driven pumpset, DOL starter for Jockey pumpset complete with isolator switch, voltmeter, ammeter manual / auto mode switch, indicating lamps etc., Potential free contacts pumps, for third party integeration for Fire alarm system, BMS, etc., for identifying the on/off status, trip status for all pumps and lube oil level status for diesel driven pump. \nIncomer shall be with mechanical interlock with 2 lock & 1 Key \nINCOMING : 2 Nos, 400A 4 Pole 35KA MCCB, 400A TP&N copper Busbars with colour coded heat shrinkable PVC sleeves. 1 Set of RYB indicating lamps with individual HRC control fuses. 1 Nos. 96 sq.mm, 0-630 Amps, Ammeter with selector switch and suitable rated current transformers. 1 Nos. 0-400 96sq.mm, Voltmeter with selector switch.\nOUTGOING : Feeder for main pumps - 2nos. 250 A TP&N 35KA MCCB and Star & Delta Starter with overload relay, single phase preventor and indicating lamps with ON/OFF push buttons. \nFeeder for Jokey Pump - 2nos. 1 No 63A 25 KA TP&N MCCB without releases DOL starterwith over load relay, single phase preventor and indicating lamps with ON/OFF push buttons, 1 No . Automanual selector switch. \n1no Dummy provision. and 1no 16A TP MCCB for battery charger and control panel.\n\n\n | 1 | Set | |
1124 | 6.029 | Supplying, Installation, Testing and Commissioning of PVC insulated, XLPE, aluminium conductor, 1.1 KV grade armoured, MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970 | |||
1125 | 6.03 | 3 1/2 X 95 sqmm | 90 | Mtr. | |
1126 | 6.031 | 4C X 16 sqmm | 24 | Mtr. | |
1127 | 6.032 | 12 C X 2.5 sqmm copper aromoured cable for Diesel engines. | 48 | Mtr. | |
1128 | 6.033 | 2 C X 2.5 sqmm copper aromoured cable for instrumentation | 90 | Mtr. | |
1129 | 6.034 | Supplying, Installation, Testing and Commissioning of cable end termination with brass compression gland and Aluminium lugs for the following sizes of PVC Insulated XLPE Aluminium armoured conductor cable of 1.1KV grade complete as required.. | |||
1130 | 6.035 | 3 1/2 X 95 sqmm | 8 | Set | |
1131 | 6.036 | 4C X 16 sqmm | 2 | Set | |
1132 | 6.037 | 12 C X 2.5 sqmm copper aromoured cable for Diesel engines. | 2 | Set | |
1133 | 6.038 | 2 C X 2.5 sqmm copper aromoured cable for instrumentation | 20 | Set | |
1134 | 6.039 | Providing and fixing 25 mm x 3 mm copper strip on surface or in recess for connections etc. as required. | 45 | Mtr. | |
1135 | 6.04 | Providing and fixing following sizes of copper wire on surface or in recess for connections etc. as required. | |||
1136 | 6.041 | 8 SWG Copper | 45 | Mtr. | |
1137 | 6.042 | Supplying, Installation, Testing and Commissioning of perforated G.I.sheet cable tray with neccessory angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size of the tray shall be as mentioned below for laying the above mentioned cables. | |||
1138 | 6.043 | 600mm | 30 | Mtr. | |
1139 | 6.044 | 300mm | 30 | Mtr. | |
1140 | 6.045 | 150mm | 30 | Mtr. | |
1141 | 6.046 | Supplying, Installation, Testing and Commissioning of diesel pump exhaust, 100mm Dia MS pipe with residential type silencer, mineral wool thermal insulation and 24G aluminium cladding, with necessary supports, clamps, bolts, nuts, etc., | 45 | Mtr. | |
1142 | 6.047 | Supplying and Erection Structural Supports like MS Angle / Channel / 'U' clamps, etc., | 750 | Kgs. | |
1143 | 6.048 | GRAND TOTAL | |||
1144 | 6.049 | HYDRANT & SPRINKLAR | |||
1145 | 6.05 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. | |||
1146 | 6.051 | 200 mm NB | 1355 | RMT | |
1147 | 6.052 | 80 mm NB | 50 | RMT | |
1148 | 6.053 | Work will include painting for the above ground piping with one coat of primer and two coat of enamel paint of approved colour. Work will include cleaning of pipe, degreasing, necessary supports, clamps, bolts, nuts,etc. Headers shall be worded indicating the direction of the pipe and its purpose. | |||
1149 | 6.054 | 200 mm NB | 1070 | RMT | |
1150 | 6.055 | 150 mm NB | 337 | RMT | |
1151 | 6.056 | 100 mm NB | 36 | RMT | |
1152 | 6.057 | 80 mm NB | 184 | RMT | |
1153 | 6.058 | Supplying, Installation, Testing and Commissioning of C.I. body, EPDM seat, SGI disc, Butterfly valve PN 16, SGI Hand lever operated, wafer ends conforming to BS:5155. | |||
1154 | 6.059 | 200 mm NB. | 5 | Nos. | |
1155 | 6.06 | 150 mm NB. | 16 | Nos. | |
1156 | 6.061 | 100 mm NB. | 33 | Nos. | |
1157 | 6.062 | Supplying and installation of RCC Hume pipes of 600 mm dia with collars for road / below floor crossing of Fire water pipes as per IS 458. The rate shall includes excavation, soil levelling for bed and ends shall be closed with Brick masonry work as directed by site engineer. | 180 | RMT | |
1158 | 6.063 | Supplying, Installation, Testing and Commissioning of Air Release Valve with Ball Valve - 25 mm dia to all wet risers all complete. | 32 | Nos. | |
1159 | 6.064 | Supplying, Installation, Testing and Commissioning of Internal hydrants including landing valve stations hose reels, etc., comprising of the following. | |||
1160 | 6.065 | 63mm dia Twin outlet landing valve as per IS : 5290 together with cap and chain. | 48 | Nos. | |
1161 | 6.066 | Hose reel drum assembly with swinging and rolling arrangement together with 19mm dia x 45.0 mtrs. long hose, cnc machined Single rod IS standard Bright Material with Special “O” rings & Grooved Nozzle. and 6.25mm nozzle durable Nylon material, Jet spray & shut by hand revolving., 19mm NB ball valve at tap-off etc., as per IS : 884. | 48 | Nos. | |
1162 | 6.067 | 2 nos - 65 mm dia R.R.L Hose of 15 Mtrs. Length, together with heavy GM couplings combined with 2 nos nozzle & branch pipe as per IS2871. | 48 | Nos. | |
1163 | 6.068 | Supplying, Erection, Testing and Commissioning of MS hose cabinet stand mounted type, fabricated out of M.S sheet of 16 swg, with glass fronted (4mm thick glass with rubber beeding) door and size of the cabinet shall be 900mm x1200 mm x 250 mm, Qouted rate shall be includes suitable stand for mounting as fastners etc., and cabinet shall be powder coated of approved colour both inside and outside. | 48 | Nos. | |
1164 | 6.069 | Supplying, Installation, Testing and Commissioning of External standpost type Yard hydrants comprising of the following. | |||
1165 | 6.07 | 63mm dia Single hydrant valve as per IS : 5290 together with cap and chain. | 33 | Nos. | |
1166 | 6.071 | 2 nos - 65 mm dia R.R.L Hose of 15 Mtrs. Length, together with heavy GM couplings combined with 1 nos nozzle & branch pipe. | 33 | Nos. | |
1167 | 6.072 | Supplying, Installation, Testing and Commissioning of MS hose cabinet stand mounted type, fabricated out of M.S sheet of 16 swg, with glass fronted (4mm thick glass with rubber beeding) door and size of the cabinet shall be 600mm x750 mm x 250 mm, Qouted rate shall be includes suitable stand for mounting as fastners etc., and cabinet shall be powder coated of approved colour both inside and outside. | 33 | Nos. | |
1168 | 6.073 | Supplying, Installation, Testing and Commissioning of Fire brigade inlet siamese connection (4way) manifold in including valves and check valve of size 150mm size along with 4 nos. 63mm dia instantaneous inlet arrangements to the main header with cap and chain etc., for external hydrants. | 1 | No. | |
1169 | 6.074 | Supplying, Installation, Testing and Commissioning of Fire brigade inlet siamese connection (4way) manifold in including valves and check valve of size 150mm size along with 4 nos. 63mm dia instantaneous inlet arrangements to the main header with cap and chain etc., for fire sump. | 1 | No. | |
1170 | 6.075 | Construction of Valve Pits Size of 1000 x 1000 mm outer dimension and to be required. internal dimension as under, upto 1.5 Mtr depth with brick masonry in cement mortor 1:5, with thickness of masonry 225mm, 1:3:6 cement concrete foundation 150mm thick over 150mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface & finished with floating coat of neat cement. Fixing of 600*600 including precasting D.I. manhole heavy duty grade C-250,weight of cover must be 90kg theft proof cover and frame including painting of the frame & cover .The work shall include all necessary excavation and back filling. | 38 | Nos. | |
1171 | 6.076 | SPRINKLER SYSTEM | |||
1172 | 6.077 | Supplying, Installation, Testing and Commissioning of FM approved & UL listed Control Valve consisting of - 1 no. Alarm valve(Clapper check type, Vertical mount), 1 no. Main stop valve, 1 no. water motor with alarm gong (light weight non metallic material), with strainer, Pressure guage drain valve and proper drain piping etc., as per specification. | |||
1173 | 6.078 | i) 200 mm dia. | 1 | Set | |
1174 | 6.079 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : | |||
1175 | 6.08 | 200 mm NB | 1070 | RMT | |
1176 | 6.081 | 150 mm NB | 1338 | RMT | |
1177 | 6.082 | 100 mm NB | 628 | RMT | |
1178 | 6.083 | 80 mm NB | 1415 | RMT | |
1179 | 6.084 | 65 mm NB | 1813 | RMT | |
1180 | 6.085 | 50 mm NB | 2916 | RMT | |
1181 | 6.086 | 40 mm NB | 5454 | RMT | |
1182 | 6.087 | 32 mm NB | 2246 | RMT | |
1183 | 6.088 | 25 mm NB | 10962 | RMT | |
1184 | 6.089 | Supplying, Installation, Testing and Commissioning of C.I. Butterfly valve PN 16 Hand lever operated, wafer ends conforming to BS:5155. | |||
1185 | 6.09 | 200 mm NB | 4 | Nos. | |
1186 | 6.091 | 150 mm NB | 52 | Nos. | |
1187 | 6.092 | 100 mm NB. | 6 | Nos. | |
1188 | 6.093 | 80 mm NB. | 44 | Nos. | |
1189 | 6.094 | Supplying, installation, testing and commissioning of FM approved make vane type flow switches (flow sensors) suitable to be fixed directly on line of the following diameters, with 1 NO & 1 NC potential free contacts (suitable provision for IBMS system) | |||
1190 | 6.095 | 150mm dia | 44 | Nos. | |
1191 | 6.096 | 100mm dia | |||
1192 | 6.097 | Supplying, Installation, Testing and Commissioning of chromium finish, 15mm size Upright / Pendent type sprinkler suitable to operate at 68/79 deg.C temperature(K=80). | 7727 | No | |
1193 | 6.098 | Supplying, Installation, Testing and Commissioning of chromium finish, 15mm size side wall type sprinkler suitable to operate at 68/79 deg.C temperature(K=80). | |||
1194 | 6.099 | Supplying, Installation, Testing and Commissioning of braided SS 304 flexi hose dropper 1.2mtr length with standard support accessories, neat finish, withstand system test and working pressure. | 2051 | No | |
1195 | 6.1 | Supplying, Installation, Testing and Commissioning of Rosette plates for sprinklers at False ceiling level. | 2051 | Nos. | |
1196 | 6.101 | Supplying and Erection Structural Supports like MS Angle / Channels, etc., for Pump room. | 2750 | Kgs. | |
1197 | 6.102 | Supplying and installation of hot dip GI puddle flanges, as per IS-1239, fabricated out of 6mm MS Plate, fixed at the RCC walls of the fire tanks & Over head tanks, work includes paiting with 2 coats of primer complete as required, refer tender dwgs for details. | |||
1198 | 6.103 | 300mm Dia GI flange | 1 | Nos | |
1199 | 6.104 | 250mm Dia GI flange | 3 | Nos | |
1200 | 6.105 | 200mm Dia GI flange | |||
1201 | 6.106 | 150mm Dia GI flange | 2 | Nos | |
1202 | 6.107 | 100mm Dia GI flange | 8 | Nos | |
1203 | 6.108 | 80mm Dia GI flange | 24 | Nos | |
1204 | 6.109 | Liasoning work for Obtaining Local Fire Authority NOC/Approvals for complete systyem & miscellaneous work etc. | 1 | Lot | |
1205 | 6.11 | EXTINGUISHER | |||
1206 | 6.111 | Supplying and fixing of Minimax or approved equivalent make 4.5kg CO2 Type Fire Extinguisher with fire rating 21B. Design, construction and testing as per IS 15683, supplied with Body bearing IS 7285 mark, operating temperature -30°C to +55°C, external double PU paint coating with PO shade No 538 of IS 5, Packing 7ply thick corrugated, co2 purity IS 15222, Valve IS 3224, supplied with standard accessories. | 129 | Nos | |
1207 | 6.112 | Supplying and fixing of Minimax or approved equivalent make 6kg DCP Powder type fire extinguisher, IS 15683 Gas cartridge type with fire rating 21B. Design, construction and testing as per IS 15683, Body hydro tested at 35bar, operating temperature -30°C to +55°C, external epoxy powder coating with PO shade No 538 of IS 5, supplied with standard accessories. Supplied with ISI marked gas cartridge as per IS 4947 and DCP (Sodium Bicarbonate base as per IS 4308) Cylinder must be subjected to Anti-corrosive treatment of 7 tank process. | 218 | Nos | |
1208 | 6.113 | Supplying and fixing of Minimax or approved equivalent make HFC236fa Instaprotect (modular type), 10kg ceiling mounted fire extinguisher. Body hydro tested at 35bar, operating temperature -30°C to +55°C, external epoxy powder coating with PO shade No 538 of IS 5, supplied with standard accessories.Charged pressure 8kg/cm2. Cylinder must be subjected to Anti-corrosive treatment of 7 tank process. a. Firespot-Room Protection system-Clean Agent-HFC236fa- Modular-10 kg with solenoid valve,2 nos smoke detector ,fire alarm panel,Gunnebo control unit(SMS alert for Leak alarm), Hooter. a. Firespot-Room Protection system-Clean Agent-HFC236fa- Modular-10 kg with solenoid valve,2 nos smoke detector, fire alarm panel, Gunnebo or approved equalent make control unit(SMS alert for Leak alarm),Hooter.(FOR IBMS ROOM) | 1 | Set | |
1209 | 7 | PROVIDING LIFT WORKS | |||
1210 | 7.001 | PASSENGER LIFT:- (MAIN BUILDING) Design, Supplying, Erection, Testing and commissioning of Machine room less Passenger lift with Stainless Steel finish to carry 24 passengers of 1632 Kgs as per following details\nSpeed = 1.25 Mtr / Sec; Travel Distance = 12 Mtrs, Number of Floors = G + 1, Positing of Machinery = Machine Roomless, Design of Lift Car = Stainless steel Hailine Finish, Car Ceiling - Car Floor = Sleek (small circular lights) - SS hairline finish -pvc, Type Of Car Front Entrance Protection - Power operated centre opening sliding door - stainless steel -, Land Entrance Protection (0,1 ) - Centre Opening Sliding door - Stainless Steel - Hairline Finish, Landing Door Frame (0,1 ) - Stainless steel - Hairline Finish, Type Of Control System - Microprocessor based Quadraplex Selective Collective control With / Without attendant, Special Inclusion, Battery Operated Emergency Light And Alarm Bell, Call Register Signal And Vf Door Operator, Landing Push Button In Landing Door Frames, Automatic Rescue Device, Stainless Steel Button With S.S. Cover, Full Car Operating Panel, Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour, Floor Annunciator With Music, Firemans Switch, False Ceiling In Car, Fire Rating Of Landing Doors - Two Hours, Infra Red Door Screen, Overload Warning Indicator, Scaffolding, 3 Way Intercom / Press And Speak Phone, Free Service For One Year, Pit Ladder, Ss Handrail, Lift License\nThe rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift.\nNote: Tenderer should be given options for car Interiors. The final Approval given by Client/ Engineering Consultant \nNote: Control of Operation ( Simplex /Duplex ) should follow as per Technical Specification | 4 | Nos | |
1211 | 7.002 | GOODS LIFT:- ( MAIN BUILDING ) Design, Supplying, Erection, Testing and commissioning of Machine room less Service lift with Pre Coated Steel Grey and Blue finish to carry 2000 Kgs as per following details\nSpeed = 1.00 Mtr / Sec, Travel Distance = 24 Mtrs, Number of Floors = G + 3, Positing of Machinery = Machine Roomless, Design of Lift Car = Pre-Coated steel (Grey & Blue), Car Ceiling - Car Floor = standard - standard -m.s. cheq. plate flooring, Car Fittings - Indirect LED Tubelight & Regular (Circular) - Fan\nType Of Car Front Entrance Protection - Power Operated Centre Opening 4 panel sliding door - Precoated Steel - Blue, Type Of Control System - Microprocessor Based Simplex selective collective control With / Without attendent, Special Inclusion, Battery Operated Emergency Light And Alarm Bell\nCall Register Signal And Vf Door Operator, Landing Push Button In Landing Door Frames, Automatic Rescue Device, Full Car Operating Panel, Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour, Floor Annunciator, Firemans Switch, Fire Rating Of Landing Doors - Two Hours, Infra Red Door Screen, Overload Warning Indicator, Scaffolding, Pit Ladder\nThe rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift. | 6 | Nos | |
1212 | 7.003 | ESCALATOR:- Design, Supplying, Erection, Testing and commissioning of 1000mm width Commercial Type Escalator with 0.50Mtr/Sec as per the following details Standards - EN 115, Horizontal steps - 3 Nos, Vertical Rise - 6000mm, Horizontal Span - 15951mm, Inclination - 30 degree, Gear Box - Worm Gear, Intermediate support - 1 No, Handrail Colour - Black, Balustrade Profile - Hairline Stainless steel, Balustrade Panel - 10mm thick Tempered safety Glass, Balustrade Height - 1000mm, Step - Die Cast aluminium Grey Colour with Yellow Demarcation, Combs - Die cast Aluminium, Led Traffic Light - Fixed Arrow Sign - One Each at Top & Bottom, Outside Tuss Cladding - Hairline Stainless steel on Left, Right & Bottom, Auto Start - Diffuse / Radar Sensor Type The rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift. | 4 | Nos | |
1213 | 7.004 | PASSENGER LIFT:- ( MULTILEVEL CARPARKING ) Design, Supplying, Erection, Testing and commissioning of Machine room less Passenger lift with Stainless Steel finish to carry 16 passengers of \n1088 Kgs; Speed = 1.25 Mtr / Sec, Travel Distance = 24 Mtrs, Number of Floors = G + 6, Positing of Machinery = Machine Roomless, Design of Lift Car = Pre-Coated steel (Grey & Blue), Car Ceiling - Car Floor = standard - standard -m.s. cheq. plate flooring, Car Fittings - LED Lights & Cross Flow fan, Type Of Car Front Entrance Protection - Power Operated Centre Opening 4 panel sliding door - Precoated Steel - Blue, Type Of Control System - Microprocessor Based Simplex selective collective control With / Without attendent, Special Inclusion, Battery Operated Emergency Light And Alarm Bell\nCall Register Signal And Vf Door Operator, Landing Push Button In Landing Door Frames, Automatic Rescue Device, Stainless Steel Button With S.S. Cover, Full Car Operating Panel, Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour, Floor Annunciator With Music, Firemans Switch, False Ceiling In Car, Fire Rating Of Landing Doors - Two Hours, Infra Red Door Screen, Overload Warning Indicator, Scaffolding, 3 Way Intercom / Press And Speak Phone, Pit Ladder, Ss Handrail\nThe rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift. | 4 | Nos | |
1214 | 8 | BUILDING MANAGEMENT SYSTEM - ACMV | |||
1215 | 8.001 | CENTRAL WORK STATION SYSTEM | |||
1216 | 8.002 | Supplying, Installation, Testing & Commissioning of Intel core i7 processors with min 3.4 Ghz or later configuration, 8 GB RAM expandable to 16 GB, 512 KB Pipeline burst cache, 256 Flash ROM, Can be upgraded from a diskette, 3 PCI Slots, 4 ISA slots (3 slot shared), On-board Graphics, PCI-e card with at least 1280 x, 1024 res., 1TB, 350 W switchable/50 Hz Power Supplying, 104 keys window 98 keyboard, PS/2 Compatible, wireless, RAID 5configuration, Raid 5 with Hot swap Spare, Min 4 USB and 2 nos. of 100 Mbit/s Ethernet port, Windows 8.1 professional, Office, Current Java Runtime environment, .NET Framework 1.1, 2.0, 3.51, EPA compliant Power Manager, Integrated / external speaker with audio card, Based on SNMP protocol Desk Manager, PC-Cilin or equivalent pre-loaded Anti Virus Software (minimum for 2 years), PAQ 95 or equivalent pre-loaded Diagnostic Software, 100 Mbps Network Interface Card with wake on LAN support, Built in 16X DVD Writer, 24” LED Monitor SVGA 1024 X 768 min. Resolution with A4 Size Laser Jet colour Printer. | 2 | Set | |
1217 | 8.003 | SOFTWARE & NETWORK CONTROLLER - 8000 IO POINTS | |||
1218 | 8.004 | Supplying, Installation, Testing & Commissioning of BMS System Software : Graphical Software meeting the requirements in the Given I/O Summary and technical specifications including configuration and facility to create / provide the graphic mapping for all I/O Summary points , animate the Graphics, Navigation between pages, display of logs, changing the time zones, pop up alarms, configurable password protection for Building Management System as per Specifications. Software shall be able to communicate with Lon works, Bacnet, Mod bus devices simultaneously, open protocol, with unlimited point capacity | 1 | Nos | |
1219 | 8.005 | Supplying, Installation, Testing & Commissioning of Interface Network controller (Router) Supplying , installing, testing and commissioning of Network Supervisory Controller unit for connecting all controllers to it and transferring data to PC platform.& Soft Integration with HVAC equipments and all other 3rd party equipments | 1 | Lot | |
1220 | 8.006 | Supplying, Installation, Testing & Commissioning of Network Controller Access: Multiple Operator Access with Max support for User Access Level with passwords with various configuration privileges for monitoring and control of DDC Controllers - using with Open protocol(for integeration controllers) All Integeration controllers should be enclosed in Rittal Panels with Proper power Supplying and Connections | |||
1221 | 8.007 | Chiller plant manager integration - 240 points | 1 | Lot | |
1222 | 8.008 | Chiller pump panel integeration - 200 points | 1 | Lot | |
1223 | 8.009 | Energy meters - 150 Points | 1 | Lot | |
1224 | 8.01 | LIFT integration - 200 points | 1 | Lot | |
1225 | 8.011 | DG Integration - 200 points | 1 | Lot | |
1226 | 8.012 | FAS Integration - 1500 points | 1 | Lot | |
1227 | 8.013 | VFD Integration - 2000 points | 1 | Lot | |
1228 | 8.014 | Solar Panel Integration - 250 points | 1 | Lot | |
1229 | 8.015 | STP Integration - 200 points | 1 | Lot | |
1230 | 8.016 | UPS Integration - 200 points | 1 | Lot | |
1231 | 8.017 | Portable operator terminal kit for stand alone programming. | 1 | Set | |
1232 | 8.018 | DDC CONTROLLERS | |||
1233 | 8.019 | Supplying, Installation, Testing & Commissioning of Automation stations / DDC Controller with I/O module etc., The controllers shall be microprocessor based standalone and net workable type with real time clock and historical database of min 1 MB. The DDC's shall be capable of peer to peer communication without help of system interface controller or PC. with locable mounting cabinets duly powder coated connector strip, internal wiring and space to house controller & relays, connector strip current transformer, MCB, internal wiring. (Contractor shall confirm his I/O provision w.r.t requirement on basis of data point) on BACnet /IP. Ref IO Summary | |||
1234 | 8.02 | DDC Controller with Rittal enclosures for Chiller , Pumps etc | 1 | nos | |
1235 | 8.021 | DDC Controller with Rittal Enclosures for Tank Levels 2 nos Rain Water Tank | 1 | nos | |
1236 | 8.022 | DDC Controller with Rittal Enclosures for Tank Levels Raw Water Tank -2 nos. 2. Treated Water Tank -2nos 3. Fire Tank Water - 1no, 4. RO Tank - 1 no. | 1 | nos | |
1237 | 8.023 | DDC for HSD Tank | 1 | nos | |
1238 | 8.024 | DDC for Ventilation Fans (132 Fans, 12 Carpark Ventilation) | 1 | LOT | |
1239 | 8.025 | Supplying, Installation, Testing & Commissioning of below Field Devices | |||
1240 | 8.026 | Outside Air Temperature , RH Sensor & CO2 sensor | 1 | nos | |
1241 | 8.027 | Immersion Temp Sensor - 200 mm Length | 16 | nos | |
1242 | 8.028 | Duct Temp Sensor | 180 | nos | |
1243 | 8.029 | Water Level Switch including with High & Low Level | 11 | nos | |
1244 | 8.03 | Flame proof Level Switch with High & Low Level | 2 | nos | |
1245 | 8.031 | BTU meter - 250 mm dia | 3 | nos | |
1246 | 8.032 | Supplying, Installation, Testing & Commissioning of below cables, conduits & trays | |||
1247 | 8.033 | Signal cable for analog input & outputs : 2 Core X 1.5 mm PVC sheathed shilded copper unarmored cable. | 15000 | Rmt | |
1248 | 8.034 | Signal cable for digital input & outputs : 4 Core X 1.0 mm PVC sheathed unshilded copper unarmored cable | 10000 | Rmt | |
1249 | 8.035 | 25mm dia PVC Conduit with Accessories | 15000 | Rmt | |
1250 | 8.036 | 25mm dia GI Conduit with Accessories | 3500 | Rmt | |
1251 | 8.037 | Supplying and Erection of perforated 300mm cable tray with cover, neccesary supports, bolts, nuts, etc | 500 | Rmt | |
1252 | 8.038 | FIRE ALARM SYSTEM | |||
1253 | 8.039 | Supplying, Installation, Testing, and Commissioning of Intelligent Addressable Panel. The Panel should have LCD Display with a minimum 640 Characters, Battery supervision, flash EPROM memory, walk test, 4 operator access levels, 1000 historical event log, zone and individual selectable settings and programme features. The panel should be configured for 48 hours normal working conditions and operate for a minimum of 2Hrs during emergency. The Panel should have all features and functions mandated by NFA, BIS. The Panel should be configured for a minimum of 3000 devices with additional capacity to spare 10% devices. The panel should be supplied inclusive of Battery, Programming Interface board, Communication Board, Programming Software, Monitoring Software, and requisite number of loop cards. Each loop card should be able to connect atleast 159 devices. The panel should be UL or FM Listed. The panel shall be in single enclosure panel with expandable provisions. The panel shoul suppport Bacnet Over IP, for BMS integeration. | |||
1254 | 8.04 | 10 Loop panel with 5 Loop Cards | 1 | Set | |
1255 | 8.041 | Supplying, Installation, Testing, and Commissioning of Passive Repeater Panel with LCD Display, 640 Characters for monitoring the Fire Alarm System. The display should provide events and messages as displayed on the main fire alarm system panel. Should be UL or FM Listed. | 1 | Set | |
1256 | 8.042 | Supplying, Installation, Testing, and Commissioning of Addressable Heat Detector with Rate of Rise detection of 15 degree F to 20 degree F per minute, and detect Fixed Temperature of 100 degree F. The detector will have LED indicatoors with 360 degree view with indetifiable indications for fault, normal, communication, emergency operation modes. Should be supplied with Base & Junction Box complete with all accessories. Should be UL or FM Listed. | 50 | Nos | |
1257 | 8.043 | Supplying, Installation, Testing, and Commissioning of Addressable Multi Sensor Detector with Optical Smoke detection, Rate of Rise detection of 15 degree F to 20 degree F per minute, and detect Fixed Temperature of 100 degree F. The detector will have LED indicatoors with 360 degree view with indetifiable indications for fault, normal, communication, emergency operation modes. Should be supplied with Base & Junction Box complete with all accessories. Should be UL or FM Listed. Below Ceiling | 539 | Nos | |
1258 | 8.044 | Supplying, Installation, Testing, and Commissioning of Addressable Multi Sensor Detector with Optical Smoke detection, Rate of Rise detection of 15 degree F to 20 degree F per minute, and detect Fixed Temperature of 100 degree F. The detector will have LED indicatoors with 360 degree view with indetifiable indications for fault, normal, communication, emergency operation modes. Should be supplied with Base. Should be UL or FM Listed. Above Ceiling | 172 | Nos | |
1259 | 8.045 | Supplying, Installation, Testing, and Commissioning of Response/Remote Indicators | 172 | Nos | |
1260 | 8.046 | Supplying, Installation, Testing, and Commissioning of Addressable Beam Detector. Should be a UL or EN approved device capable of electronically addressable, compensation ageing, capable of alerting slow accumulation of dust particles after a threshhold level. Should be effective for optical distances of 8 to 100 meters. Should be supplied along with Reciever. with Zone control | 26 | Nos | |
1261 | 8.047 | Supplying, Installation, Testing, and Commissioning of Addressable Manual Calling Point. Manual Calling point should be loop powered type and resettable with lock & Key. Manual Calling Point should be of hard ABS plastic or metal construction colored in RED with instructions to operate clearly like "Press Here". Should be supplied with suitable back Boxes and bases. The Manual Calling Point should be mounted at 1.4m, easily reachable and convenient location as marked in the drawings. Should be UL or FM Listed. | 97 | Nos | |
1262 | 8.048 | Supplying, Installation, Testing, and Commissioning of Addressable Loop operated combined sounder and strobe. The Sounder should be programmable for controlling the sound level like 65dB, 75dB, 85dB etc. Sounder Tone and Strobe blink rate should be programmable. The Sounder with Strobe should be loop powered, and mounted at 2.1m height. Should be UL or FM Listed. | 86 | Nos | |
1263 | 8.049 | Supplying, Installation, Testing, and Commissioning of Addressable Isolators. Should isolate the affected loop portion in case of fault or shortcircuit. Should be able to reste once the fault is removed. Should be capable of monitoring upto 30 or more devices. Should be UL or FM Certified. Should be supplied with base. | 39 | Nos | |
1264 | 8.05 | Supplying, Installation, Testing, and Commissioning of Addressable Monitor Module. Should be able interface non addressable devices and communicate with the panel. Should be UL or FM certified. | 74 | Nos | |
1265 | 8.051 | Supplying, Installation, Testing, and Commissioning of Addressable Control Relay module, Tripping of Third Party Equipment, MS Powder coated Junction Box for mouting on Surface. The CR will be connected to Deactivating AHUs, Lifts & activating the Public Address system, Control Relay Modules in suitable ABS Plastic glossy Box. | 136 | Nos | |
1266 | 8.052 | Supplying and laying, connecting & commissioning of 2C x 1.5 sq.mm, Armoured Stranded Copper conductor, FRLS Cable 650 V as per IS 1554. | 13990 | Rmt | |
1267 | 8.053 | 25mm dia GI Conduit with Accessories | 4500 | Rmt | |
1268 | 8.054 | GI perforated tray of 300mm width with 1.5mm thickness | 500 | Rmt | |
1269 | 8.055 | PUBLIC ADDRESS MANAGEMENT SYSTEM | |||
1270 | 8.056 | Supplying, Installation, Testing and commissioning of 20 Zone Call Station, Stem Type Microphone, 2 mm thick CRCA Sheet Powder Coated Rack, Dual Tone Control for Speech & Music, integration facility with Fire Alarm System, tone generator & Speech Processor with relays for activating tone & per-recorded fire alarm messages, facility to integrate with the base builder P.A System as specified in the Tender Specifications . The rate inclusive of Priority module, selector switch etc. | 1 | Nos | |
1271 | 8.057 | Supplying, Installation, Testing and Commissioning of Rack Mounted minimum 480 W mixer Amplifier | 9 | Set | |
1272 | 8.058 | Supplying, Installation, Testing and Commissioning of Rack Mounted minimum 240 W mixer Amplifier | 6 | Nos | |
1273 | 8.059 | Supplying, Installation, Testing and Commissioning of Rack Mounted minimum 120 W mixer Amplifier | 1 | Nos | |
1274 | 8.06 | Supplying, Installation, Testing and Commissioning Voice Alarm Controller with router | 1 | Set | |
1275 | 8.061 | Supplying, Installation, Testing and commissioning of Wireless Mic | 1 | Set | |
1276 | 8.062 | Supplying, Installation, Testing and commissioning of Gooseneck Mic | 1 | Nos | |
1277 | 8.063 | Supplying, Installation, Testing and commissioning of auto dialer for Fire Alarm System. | 1 | Nos | |
1278 | 8.064 | Supplyinging, installing, testing and commissioning of 1 No. each of AM/FM Tuner with World space receiver , DVD player with overriding facility, Music Source Selector, with assignable priority on each channel to accept Music, Telephone, Microphone, Recorded message from Voice recorder etc., with in-built compressor and limiter. - License for World space receiver also need to be included for 6 years | 1 | Set | |
1279 | 8.065 | Speakers | |||
1280 | 8.066 | Supplying, Installation, Testing and commissioning of 6 Watt Wall Mounted Metal Speakers with line matching transformers & selectable tap setting | 136 | Nos | |
1281 | 8.067 | Supplying, Installation, Testing and commissioning of 15 Watt Wall Mounted Metal Speakers with line matching transformers & selectable tap setting | 176 | Nos | |
1282 | 8.068 | Supplying, Installation, Testing and commissioning of 30 Watt Wall Mounted Metal Speakers with line matching transformers & selectable tap setting | 53 | Nos | |
1283 | 8.069 | Cabling and Accessories | |||
1284 | 8.07 | Supplying, Installation, Testing and commissioning of 19", 48 U Floor mount Rack to mount the Amplifiers. | 2 | Set | |
1285 | 8.071 | Supplying and laying of 2 Core 1.5 Sq.mm Armoured unshielded Cable | 8278 | Rmt | |
1286 | 8.072 | 25mm dia GI Conduit with Accessories | 3400 | Rmt | |
1287 | 8.073 | CCTV SYSTEM | |||
1288 | 8.074 | Supplying, Installation, Testing and commissioning of Workstation: Supplying, Installation, Testing and commissioning of IBM PC compatible system minimum of i5, 8GB RAM, 1TB Hard Disk, Optical Reader/Writer Drive, Wired Keyboard, Display with 2 or more PCI Expansion Slots, 2 or more USB 2.0 or later ports, 1 RS232 or RS485 port, Windows 7 Professional or later, Antivirus Software with Licenses. | 2 | Set | |
1289 | 8.075 | Supplying, Installation, Testing and commissioning of LED Monitors, 40” 1,920 x 1,080 (16:9) | 2 | Nos | |
1290 | 8.076 | Supplying, Installation, Testing and commissioning of NVR, Embedded System with LCD Display, 2GB or more memory, Support Raid 0, 1, 5, Multiple Ethernet ports with aggregate/trunk multiple ports capabilities. Should support minimum bandwidth of 192Mbps. Should be capable of Recording 64Ch @1080p and storage capacity of storing for 15 days of 64Cameras@1080p, 30fps. | 5 | Nos | |
1291 | 8.077 | Supplying, Installation, Testing and commissioning of Surveillance Grade 6Gbps, 3.5" Hard disks, 4TB, 7200rpm | 40 | Nos | |
1292 | 8.078 | Supplying, Installation, Testing and commissioning of IP 2MP Dome Cameras, IR Range 20m Supplying, Installation, Testing and commissioning of IP IR Dome Cameras, 1/2.7” Image Sensor, 3.6mm 1080P(1920×1080) @25FPS, with Dual Stream H.264 Main Profile and MJPEG. Should support PoE Power (802.af Type 1). Should support Smart Detection, DWDR, Day/Night (ICR), 3DNR, AWB, AGC, BLC features. 0.01Lux/F2.0 (Color), 0Lux/F2.0(IR on). IR Range should be 30m or more. Camera should be IP65 rated or more. | 79 | Nos | |
1293 | 8.079 | Supplying, Installation, Testing and commissioning of IP 2MP Bullet Cameras, IR Range 50m Supplying, Installation, Testing and commissioning of IP IR Dome Cameras, 1/2.7” Image Sensor, 3.6mm 1080P(1920×1080) @25FPS, with Dual Stream H.264 Main Profile and MJPEG. Should support PoE Power (802.af Type 1). Should support Smart Detection, DWDR, Day/Night (ICR), 3DNR, AWB, AGC, BLC features. 0.01Lux/F2.0 (Color), 0Lux/F2.0(IR on). IR Range should be 30m or more. Camera should be IP65 rated or more. | 37 | Nos | |
1294 | 8.08 | Supplying, Installation, Testing and commissioning of IP 2MP Bullet Camera, IR Range 30m Supplying, Installation, Testing and commissioning of IP IR Bullet Cameras, 1/2.7” Image Sensor, 3.6mm 1080P(1920×1080) @25FPS, with Dual Stream H.264 Main Profile and MJPEG. Should support PoE Power (802.af Type 1). Should support Smart Detection, DWDR, Day/Night (ICR), 3DNR, AWB, AGC, BLC features. 0.01Lux/F2.0 (Color), 0Lux/F2.0(IR on). IR Range should be 30m or more. Camera should be IP65 rated or more. | 73 | Nos | |
1295 | 8.081 | Supplying, Installation, Testing and commissioning of PTZ cameras | 5 | Nos | |
1296 | 8.082 | L3 Manageable Gigabit Switches Supplying, Installation, Testing and commissioning of L2/L3 Manageable switches with VLAN, QoS, Stackable, and Rack Mountable, 24 Ports. Switch should be capable of switching 55+ Gbps and forwarding 40+ Million packets/second. Should have separate Uplink ports and Stacking ports. Should have VLAN, QOS Features. Should support 4K VLANS. Should support Link Aggregation, STP, Port Grouping. Should have Web and CLI based Management interface and support RADIUS, SNMP, MIBs (Standard and Private). Switch should have minimum 24 Ports PoE. Should be supplied inclusive of Patch Panels. | 23 | Nos | |
1297 | 8.083 | Supplying, Installation, Testing and commissioning of Network Racks, 6U, Floor Mount Supplying, Installation, Testing and commissioning of 6U Network Rack inclusive of Mounting Accessories, Cable Manager, Fixtures, 1x24 Port Patch Panels. | 30 | Set | |
1298 | 8.084 | Supplying, Installation, Testing and commissioning of Network Racks, 42U, Floor Mount Supplying, Installation, Testing and commissioning 42U Network Rack Accessories, Fixtures, Power Managers, Ventilation Fans, Cable Managers and Organizers, Castor Wheels. Side and Back Doors should be removable with Front side door. | 2 | Set | |
1299 | 8.085 | Supplying, Installation, Testing and commissioning of Gigabit Media Converters or SFP Modules inclusive of LJU, Splicing, Patch Cables, Pigtails | 60 | Set | |
1300 | 8.086 | Supplying, laying, Testing and commissioning of CAT6 cable from Network Switches to End Devices (Cameras, Access Controllers) | 10539 | Rmt | |
1301 | 8.087 | Supplying, laying, Testing and commissioning of Cabling of 6 Cores, Armored SM Optical Fiber Optic Cable from Switches, to CMS Room | 990 | Rmt | |
1302 | 8.088 | Supplying, laying, Testing and commissioning of 25mm PVC Conduit with necessary accessories | 7500 | Rmt | |
1303 | 8.089 | Supplying, laying, Testing and commissioning of 25mm GI Conduit with necessary accessories | 3900 | Rmt | |
1304 | 8.09 | Supplying and Erection of perforated 300mm G.I.cable tray with cover, neccesary supports, bolts, nuts, etc | 400 | Rmt | |
1305 | 8.091 | Supplying and Erection of perforated 450mm G.I cable tray with cover, neccesary supports, bolts, nuts, etc | 300 | Rmt | |
1306 | 8.092 | ACCESS CONTROL SYSTEM - Access & Attendance Management System | |||
1307 | 8.093 | Access Management Workstation: Supplying, Installation, Testing, and commissiong of IBM PC compatible system minimum of i5, 8GB RAM, 1TB Hard Disk, Optical Reader/Writer Drive with 21” or more LED Display Panel, Wired Keyboard, Display with 2 or more PCI Expansion Slots, 2 or more USB 2.0 or later ports, 1 RS232 or RS485 port, Windows 7 Professional or later, Antivirus Software with Licenses. | 1 | Nos | |
1308 | 8.094 | Network Management Controller: Supplying, Installation, Testing, and commissiong of Network Management Controller with Access Management Software, requisite Software User License for 1000 users, 65000 Door Access Controllers. Should support 255 Door Access Controllers, work in Independant and Network Modes. Aux In, and Out forts for integration with Fire Alarm System. Controller should support 25,000 Users and 500,000 Events log or more. | 1 | Set | |
1309 | 8.095 | Biomteric Attendance System: Supplying, Installation, Testing, and commissiong of Biomteric Attendance System with Finger Print Recognition, Support for 1:1, and 1:N recognitions modes. Should be able to work offline and online. Should have capacity to store 3000 fingerprints or more, and 50,000 log transactions. Software should have user security and Dialy, Weekly, Monthly attendance reports with facility to export data. Software should be user friendly, and work on Windows 7 or later systems | 3 | Nos | |
1310 | 8.096 | Door Access Controller: Supplying, Installation, Testing, and commissiong of of Door Access Controller with built-in Mifare Contactless Card Reader, 50,000 Events Storage, EM Lock interface, Exit Reader interface, Exit Switch i/p. Should be able to communicate over RS-485 or Network Interfaces. Should be rated for IP65, and have visual led indicators. Should draw power from PoE port, Accept cards conforming to ISO 7810 ID1 size, and ISO/IEC14443. Optionally it may have 12v DC input. Supplying should be inclusive of Backboxes and Accessories | 10 | Nos | |
1311 | 8.097 | Exit Readers: Supplying, Installation, Testing, and commissiong of Mifare Contactless Readers. Should accept cards conforming to ISO 7810 ID1 size, and ISO/IEC14443 mifare standards. Should IP65 rated, visula led indicators. Power should be drawn from Door Access Controller and may have 12v DC input. Should have RS232/RS485/Wiegand or suitable interface to communicate with Door Access Controller. Supplying should be inclusive of Backboxes and Accessories | 10 | Nos | |
1312 | 8.098 | Emergency Door Release Switch (Glass Break type) Supplying, Installation, Testing, and commissiong of Glass break type Emergency Door Release Switch. Material may be plastic, color Green. Should be able to work minimum 3A at 36V DC or 50V AC. Should be clearly marked with ‘Emergency Exit Release’, ‘Break Glass’ and ‘Press to Exit’ or similar. | 10 | Nos | |
1313 | 8.099 | Exit Switches Supplying and Installation of SS Exit Switches with back boxes. Should be clearly marked with ‘Press to Exit’ or ‘Exit Switch’ or suitable. Supplying should be inclusive of Backboxes. Should be able to handle 3A, 230vAC, Contact to have SPST with push to latch and release, mechanical life of 50000 cycles. | 10 | Nos | |
1314 | 8.1 | Door Locks, Single Leaf Supplying, Installation, Testing, and commissiong of Single EM Lock with built-in Magnetic Contacts, Door Open signal. Should work with either 12v or 24v power Supplying and a holding force not less than 600Lbs. Should be supplied with suitable L, Z, U Brackets. | 7 | Nos | |
1315 | 8.101 | Door Locks, Double Leaf Supplying, Installation, Testing, and commissiong of Double EM Lock with built-in Magnetic Contacts, Door Open signal. Should work with either 12v or 24v power Supplying and a holding force not less than 2x600Lbs Should be supplied with suitable L, Z, U Brackets. | 3 | Nos | |
1316 | 8.102 | Mifare Contactless Cards: Supplying and Printing of cards conforming to ISO 7810 ID1 size, and ISO/IEC14443. | 1200 | Nos | |
1317 | 8.103 | Supplying and Cabling of CAT6 from Network Switches to Door Controllers | 1700 | Rmt | |
1318 | 8.104 | Supplying and Laying of 25mm PVC Conduit with necessary accessories | 350 | Rmt | |
1319 | 8.105 | 25mm dia GI Conduit with Accessories | 2500 | Rmt | |
1320 | 8.106 | Supplying and Cabling of Un-Armored 4 Core 1.0sqmm from EM Lock to Door Access Controllers | 350 | Rmt | |
1321 | 8.107 | Supplying and Laying of 20mm PVC Conduit with necessary accessories | 350 | Rmt | |
1322 | 8.108 | Supplying and Cabling of Un-Armored 2 Core 1.0sqmm from Door Access Controller to Exit Switch / Emergency Release Switch | 350 | Rmt | |
1323 | 8.109 | Supplying and Laying of 20mm PVC Conduit with necessary accessories | 350 | Rmt | |
1324 | 9 | SEWAGE TREATMENT PLANT\nSupplying, installation, Testing and Commissioning of 250KLD Capacity SBR ( Sequence Batch Reactor) including all equipment / machinaries with following components & process:-\n( Process - Airlift arrangement and functional mechanisms, technology from Germany 4 Charging / 4 Discharge / 4 Sludge Transfer )\n1. Fine Bar Screen made up of SS 304 with 6mm spacing. Size L=800mm; W=1000mm = 1 No;\n2. Controller with Panel board ( Class IP 55/65 ) for the enclosure of controller and necessary electrical equipment’s (phase failure relay, MPCB, Contactors) = 1 No; \n3. Air Compressor of approved Germany make 340 cum / Hr ( Capacity 12.5HP operating Pressure @ 0.8 bar with 3phase Supply ) = 2 Nos; \n4. EPDM Fine bubble tubular diffusers 90 mm Dia,1m Long with SOTE>10.5% / m = 42 Nos;\n5. Diffusion system in SS 304 ( 6 outputs ) stands = 14 Nos;\n6. Hose, PVC braided from Polyhose at 10 kg / sqcm at temperature rating of 115 deg. C = 200Mtr;\n7. Clamps and fittings for wall mounting in SS 304 = 150Nos;\n8. Solenoid valves for airlift arrangement (Aira / Equivalent) (1.5”-2”) = 8 Nos;\n9. Submersible Monobloc Pump with 16 Cum / Hr Flow = 2 Nos \n10. MS Vessel with Multiport Valve 1200 mm dia, 1800mm height HOS Vessel Filter Media Sand, carbon and Supporting Media = 1 No;\n | 1 | LOT | |
1325 | 9.001 | COMPRESSOR SYSTEM | |||
1326 | 9.002 | Supplying, Installation, testing and commissioning of Kaeser or equivalent make, Oil Flooded, Twin Rotary, Positive displacement, SCREW AIR COMPRESSOR, Motor Driven, With all necessary accessories, with built in Star Delta Starter, with neccessary integeration between both the drives, antivibration pads, Fittings having the following specifications, 55 KW, having FAD of 356 CFM at 7 bar working pressure and it shall be max of 8.5bar pressure. The scope Supplying includes Siemens IE3 premium efficeincy, Sq.Cage Induction Motor, TEFC type, suitable for operation on 400 V± 10%, 3 Phase, 50 Hz, AC Supplying, and for ambient temperature 45deg F Class insulation conforming to IS 1271, & drain arrangements. Scope of work includes cabling end terminations. The compressor controller shall be secured and RFID accessible and recovery of data shall be made possible with inbuilt SD card to track the data and history of equipment., The system should be IBMS compatiable. Performance adherence of equipment shall be made with respect to ISO 1217:2009, Annexure C. The capacity must be not less than the cited above. The scope of work includes neccessary cabling apprx 15rmts, glands, termination works between the control panel and the compressor. | 2 | Nos | |
1327 | 9.003 | Installation, testing and commissioning of Kaeser or approved equivalent make, REFRIGERATED TYPE AIR DRYER, auto ON & OFF type and high COP of scroll compressor shall be placed inside With all necessary accessories, antivibration pads, Fitting & auto drain arrangement, having the following specifications, pressure dew point 3 deg, & having dryer capacity FAD of 1200 CFM with respect to design conditions, max. operating pressure 16KG/Cm2, 100% power consumption within 2.75KW with 10% tolerance, pressure drop shall be lies within 0.15 bar. The dryer shall be sized to handle max ambient temperature 40 deg C, max inlet temperature 45 deg C, Refrigerant 134A, 415V, 50Hz, 3Ph, Noise Level - less than 70 dBA. Scope of work includes, isolator, end terminations, electrical cabling between dryer and isolator apprx 15rmt. It shall contain fluorinated greenhouse gases covered by Kyoto protocol. The system should be IBMS compatiable. The capacity must be not less than the cited above. The scope of work includes neccessary cabling apprx 15rmts, glands, termination works between the control panel and the compressor. | 1 | Nos | |
1328 | 9.004 | Installation, testing and commissioning of Kaesser or approved equivalent make Pre filter which ensures compressed air quality and remove particles equivalent to 1 µm meter. It shall be sized to handle both mentioned compressor capacities. | 2 | Nos | |
1329 | 9.005 | Installation, testing and commissioning of Kaesser or approved equivalent make Pre filter which ensures compressed air quality and remove particles equivalent to 0.1 µm meter. It shall be sized to handle both mentioned compressor capacities. | 2 | Nos | |
1330 | 9.006 | Installation, testing and commissioning of receiver, working temperature 60deg C, maximum working pressure 11 Kg/cm2, all internal surfaces shall be cleaned and one coat of black bituminous paint applied. Scopoe of work includes necessary,auto condensate drain - PRESSURE LOSS Electronic Condensate Drain Valve, it shall be splash proof and works on the principle of float based as accumulated condensates can be discharged very safely without single loss of compressed air and without intervention of maneuvres), mouting bolts nuts, flanges, drain arrangement Safety valve, Syphon Pipe, Pressure Gauge & Drain Valve. - 5 Cu.M | 1 | Nos | |
1331 | 9.007 | Supplying, Installation, testing and commissioning of Overground PPR pipes -PN16 conforming to IS 15801 with All necessary fittings, such has couplers, elblows, reducers, tees, FTAs, MTAs,flanges, Unions, etc., including, clamping, bolts, nuts, angles, supports, etc. | |||
1332 | 9.008 | 80 ID | 51 | Rmt | |
1333 | 9.009 | 65 ID | 1126 | Rmt | |
1334 | 9.01 | 36 ID | 478 | Rmt | |
1335 | 9.011 | 23 ID | 67 | Rmt | |
1336 | 9.012 | Supplying of Leader/Audco make or equivalent approved make of C.I. body, EPDM seat, SS disc, Butterfly valve PN 16, SGI Hand lever operated, wafer ends conforming to BS:5155. The scope of work includes requried flanges to connect the pipes, etc., | |||
1337 | 9.013 | 80 NB (threaded connection type) | 2 | Nos | |
1338 | 9.014 | 65 NB (threaded connection type) | 2 | Nos | |
1339 | 9.015 | 50 NB (threaded connection type) | 2 | Nos | |
1340 | 9.016 | Supplying of Leader/Audco make or equivalent approved make of Brass Ball valve PN25 with lever operated chromium plated brass ball suitable for threaded end connection. | |||
1341 | 9.017 | 40 NB (threaded connection type) | 30 | Nos | |
1342 | 9.018 | 25 NB (threaded connection type) | 12 | Nos | |
1343 | 9.019 | Supplying and construction MS Structure Work including Angels, 'C'- Channels, I- Beams with primer & painting etc. in compressor room. | 450 | Kgs | |
1344 | 9.02 | Supplying and installation of double Earthing Strip for motor body earth, scope of work includes running the earthing strip / wire from the body to main earth strips. | |||
1345 | 9.021 | GI flat 50mmx6mm | 50 | Rmt | |
1346 | 9.022 | 10SWG copper wire | 50 | Rmt |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail