Construction Of Additional Exibhition And Convention Hall, Multilevel Carparking And Utility Building For The Expansion Of Chennai Trade Centre, Nandambakkam, Mount Poonamalle, Nandambakkam, Chennai-Tamil Nadu

Tamil Nadu Trade Promotion Organisation has published Construction Of Additional Exibhition And Convention Hall, Multilevel Carparking And Utility Building For The Expansion Of Chennai Trade Centre, Nandambakkam, Mount Poonamalle. Submission Date for this Tender is 03-12-2019. Building Work Tenders in Nandambakkam, Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

22384407
Construction Of Additional Exibhition And Convention Hall, Multilevel Carparking And Utility Building For The Expansion Of Chennai Trade Centre, Nandambakkam, Mount Poonamalle
Open Tender
Indian
Tamil Nadu
Nandambakkam, Chennai
03-12-2019

Tender Details

Construction Of Additional Exibhition And Convention Hall, Multilevel Carparking And Utility Building For The Expansion Of Chennai Trade Centre, Nandambakkam, Mount Poonamalle

Key Value

Document Fees
INR 59000 /-
EMD
INR 30000000.0 /-
Tender Value
INR 254.29 Crore /-

BOQ Items

Name of Work:Construction of Additional Exibhition and Convention Hall, Multilevel Carparking and Utility Building for the Expansion of Chennai Trade Centre, Nandambakkam, Mount Poonamalle Road, Chennai - 600 089
Sl. No. Item Description Item Code / Make Quantity Units
1 1 MAIN BUILDING BI01010001010000000000000515BI0100001112
2 1.001 STRUCTURAL WORKS
3 1.002 FOUNDATION PILE
4 1.003 Charges Towards Mobilization & Demobilization of Rotary type Mait HR 180 / equivalent or Higher capacity Hydraulic rigs shall be mobilized with necessary Equipments. 3 Nos
5 1.004 \n650mm dia Pile Boring:- \nProviding and Installation bored Cast-in-situ reinforced cement concrete Piles of Grade M-30 Ready Mix Concrete having Minimum Cement Content as per IS 456 with necessary admixtures and plasticiser. Piles are end bearing piles of basic length 5.00 Mtr and additionally anchoring in the rock at bottom by 1.5 times dia of the piles in all types of soil with driving 8mm thickness of temporary steel casing with necessary stiffener bands and sharp edge at bottom; casing shall be provided up to non-collapsible strata from the existing ground level (as per Site condition), boring in over-burden and through all type of strata encountered up to the founding level as described in the drawing, socketing in approved strata, using bentonite slurry, including disposal of all bored materials etc.complete as per drawings and specifications. Rate is inclusive of Pile boring in all types of soil, Bentonite flushing, Cage lowering, Supplying and installation of concrete, Pile head chipping, Plant installation, collection of sub soil samples in each pile, etc., ( Length of pile for payment shall be measured from toe of pile to bottom of pile cap, Reinforcement will be paid separately ) In all types of soil such as Brownish Clay, Sandy Silty, Clayey sand, Very Dense Completely Weathered Rock etc., (Kindly refer soil report) \n 7249 Mtr
6 1.005 \nInitial Load Test - 2.5 Times of the Safe load (650mm dia Pile- 200 MT):- \nVertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer incharge. \n 3 Nos
7 1.006 Routine Load Test - 1.5 Times of the Safe load ( 650mm dia Pile - 200 MT) 6 Nos
8 1.007 \n650mm dia Pile Integrity testing:-\nPile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.\n 705 Nos
9 1.008 \nPile Reinforcement Works:-\nProviding, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as Pile, walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786. ( Note: Helical Reinforcement should be welded as per IS Standards, Authorized Laps, Spacer Bars and Chairs shall be measured for payment. )\n 210769 Kgs
10 1.009 CEMENT CONCRETE WORKS:-
11 1.01 \nProviding, machine mixing and laying Plain cement concrete (PCC) 1:4:8 ( 1 Cement : 4 sand : 8 graded stone aggregate 20mm nominal size ) of required thickness for foundation, rafts, plinth beams, levelling course and all locations, etc. (minimum cementitious content shall be as specified in the IS Code and as approved); including compacting, curing, required shuttering and its removal, dewatering where required and vibrating, cleaning, preparing surfaces, junctions, etc.; complete at all depths and leads as per the drawing and to entire satisfaction of the PMC/Employer. (Note: Using M - sand)\n
12 1.011 Pilecap & Tie beam 199 Cum
13 1.012 Below Grade slab ( Front Lobby & Rearside services ) 534 Cum
14 1.013 REINFORCED CONCRETE WORKS:-
15 1.014 \nProviding, transporting, pumping and laying batched design mixed, controlled concrete of different grade ( as specified in the Structural drawings ) conforming to ( IS 456 ) with minimum cement content and maximum water cement ratio as per IS or as specified by Structural Consultant including using approved quality admixtures and placed either with pump / manual / lift for following grades of concrete including compacting, vibrating, curing and protecting etc., complete at all lead, lift & heights as per the drawing and to entire satisfaction of the PMC / Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. ( No separate payment will be made by the Employer towards wastage ). ( Note: Using M - sand )\n
16 1.015 M30 Grade Concrete - ( Sl. No 1.016 to 1.020 )
17 1.016 Pilecap 2029 Cum
18 1.017 Tie beam 486 Cum
19 1.018 Grade slab 567 Cum
20 1.019 Rainwater sump 552 Cum
21 1.02 Pedastals 148 Cum
22 1.021 M35 Grade Concrete - ( Sl. No 1.022 to 1.049 )
23 1.022 Shear walls
24 1.023 Ground floor 799 Cum
25 1.024 Ground floor Mezzanine 163 Cum
26 1.025 First floor 163 Cum
27 1.026 First floor Mezzanine 163 Cum
28 1.027 Terrace floor 41 Cum
29 1.028 Columns
30 1.029 Ground floor 333 Cum
31 1.03 Ground floor Mezzanine 278 Cum
32 1.031 First floor 228 Cum
33 1.032 First floor Mezzanine 211 Cum
34 1.033 Terrace floor 43 Cum
35 1.034 Floor Slabs
36 1.035 Ground floor Mezzanine 1067 Cum
37 1.036 First floor 2746 Cum
38 1.037 First floor Mezzanine 693 Cum
39 1.038 Terrace floor 693 Cum
40 1.039 Floor Beams
41 1.04 Ground floor Mezzanine 498 Cum
42 1.041 First floor 435 Cum
43 1.042 First floor Mezzanine 278 Cum
44 1.043 Terrace floor 278 Cum
45 1.044 Staircase
46 1.045 Ground floor 117 Cum
47 1.046 Ground floor Mezzanine 104 Cum
48 1.047 First floor 96 Cum
49 1.048 First floor Mezzanine 51 Cum
50 1.049 Rainwater gutter walls at Terrace floor 216 Cum
51 1.05 FORMWORK:-
52 1.051 \nProviding, fabricating, erecting form work and deshuttering at all levels and places wherever needed / specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles.\n
53 1.052 Pilecap 2752 Sqm
54 1.053 Tie Beam 2632 Sqm
55 1.054 Shear wall at all levels 10094 Sqm
56 1.055 Columns at all levels 7419 Sqm
57 1.056 Floor Slab at all levels 13567 Sqm
58 1.057 Floor Beam at all levels 8789 Sqm
59 1.058 Staircase at all levels 2241 Sqm
60 1.059 Rainwater gutter walls 2874 Sqm
61 1.06 REINFORCEMENT WORKS:-
62 1.061 \nProviding, transporting to site, storing, de-coiling ( if required ), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete ( of same grade of concrete ) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786. ( Note:- Authorized Laps, Spacer Bars and Chairs shall be measured for payment )\n 2.04828e+06 Kgs
63 1.062 STRUCTURAL STEEL WORKS
64 1.063 \na) Primary Sections with Miniumum 5mm Thick plate Providing, fabricating, painting, transporting & erection in position of steel structure using parallel Built-up sections of structural steel plate of thickness as per design conforming to IS 2062 Grade E350 BR, and as per latest IS code with HSFG bolts 8.8 Grade. Surface preparation with SA2.5 blasting & Epoxy primer/paint with minimum 120 Microns DFT of approved make (Factory applied). This items also include preparation of shop drawings, erection drawings, scaffolding & staging, all labour, tools & required equipment’s etc. Required to complete the job as per drawing & specification. This items also includes all tests on material and weld fabricated parts as per specification.\nb) Secondary Sections:- Providing, fabricating, painting, transporting & erection in position of steel structure using Rolled sections of thickness as per design conforming to IS 2062 Grade E250 like angles, pipes, bracings etc. as per latest IS codes with HSFG bolts. Surface preparation with SA2.5 blasting & Epoxy primer/paint with minimum 120 Microns DFT of approved make. This items also include preparation of shop drawings, erection drawings, scaffolding & staging, all labour, tools & required equipment’s etc. required to complete the job as per drawing & specification. This items also includes all tests on material and fabricated parts as per specification.\nc) Cold formed sections with Minimum 1.75mm Thick sheet Providing, fabricating, transporting & erection in position of steel structure using Cold Formed sections of thickness as per design conforming to IS 2062 Grade E350 BR. as per latest IS codes with HSFG bolts. This items also include preparation of shop drawings, erection drawings, scaffolding & staging, all labour, tools & required equipment’s etc. required to complete the job as per drawing & specification. This items also includes all test on material and fabricated parts as per specification.\nd) Anchor Bolts:- Providing, fabricating, transporting of Anchor bolts Gr 4.6 with IS : 2062 Gr A standard & Minimum Yield strength of bolt shall be 250 MPa \ne) Connection Bolts:- Providing, fabricating, transporting of Connection bolt Gr 8.8 with ASTM A 325 M standard & minimum yield strength of bolt shall be 345 MPa\nf) Anchor bolts and connection bolts shall be measured under relevant items of structural steel work in kilograms. \nHowever touchup / patch Painting if necessary will permitted at site.\n
65 1.064 Columns 852012 Kgs
66 1.065 Main Truss 251988 Kgs
67 1.066 Rafter 376871 Kgs
68 1.067 Floor Beams 1.84538e+06 Kgs
69 1.068 Pipe Bracings 106167 Kgs
70 1.069 UC Bracings 63157 Kgs
71 1.07 \nDecking Sheet - 1mm thick: Providing and fixing Galvanized MS troughed metal sheet decking plate ( Galvanized to grade 275 minimum as per IS :277) for cast-in-situ RCC slab as per specification. Total coated thickness (TCT) of deck sheet shall be 1mm of trough depth of 52mm and minimum yield strength of 240 MPa of approved make. ( Note: Methodology of fixing details should be got approved from the Enginneering Consultant / Employer )\n 18133 Sqm
72 1.071 \n50mm thick PUF Panel - Roofing:- Providing, Transporting & erection of Pre fabricated & colour coated Galvalume 50mm thick PUF Panel (40 + 2Kgs/Cum) layed in Roofing by Tongue and Groove system locking, with Ribs, With Camlock and Nylon guard film on Both side.\nSheet Thickness: CCGL 0.47mm TCT; AZ 150 GSM/ 0.40mm TCT\nFire Resistance: Class B3 as per DIN 4102\nCompressive Strength: >120 kpa\nTensile Strength: >150 kpa\nShear Strength: >100 kpa\nThermal Conductivity (‘k’ Value): 0.019 w/m deg C\nClosed cells: >90%\nWater Absorption by volume (after 24 hrs): 1%\n 9815 Sqm
73 1.072 JOINTLESS STEEL FIBRE REINFORCED CEMENT CONCRETE
74 1.073 Separation Membrane:- Providing and Laying of 2 layers 200 Micron thick LDPE sheet over compacted soil. 10312 Sqm
75 1.074 Supplying and laying of M25 grade concrete as per approved mix design, mixed homogenously and supplied at appropriate workability as per the specification ( Average 150 mm thickness ) ( Note: Rate to be inclusive of tolearance limit for finishing ) 1599 Cum
76 1.075 Steel Fibre: Providing & mixing Hooked End and Glued Non balling Steel fibres Aspect ratio 65, Length 60mm and dia 0.95mm as per CE Label Mark System 1 ( Steel fibres for structural use ) at Dosage : 25kgs/m3, Dramix 4D 65/60 BG manunfactured by BEKAERT or equivalent 39975 Kgs
77 1.076 Reinforcement:- Providing and Fixing of 8mm dia @ 150mm c/c on both ways at top including of chairs, covers as per the drawings. 51560 Kgs
78 1.077 Finishing:- FM3 Levelling, Vibrating by using Laser Screed and Finishing Concrete, removing the surface undulation by Electrical Skim Floater, Special Tools and Final finishing with Ride-On- trowel to get Smooth finish to the requirement of Surface. 10312 Sqm
79 1.078 Floor Hardener ( AR Class 2 ):- Supplying and laying of Wear resistant topping of 4 - 5 mm by Non metallic floor hardener of Abrasion Class AR 2 as per BS 8204 - Part 2 at the recommended dosage of 10kgs/m2 applied on, wet on wet concrete surface of Rocland make or equivalent ( Colour : Grey ) 10312 Sqm
80 1.079 Joint Profile:- Supplying and fixing of Signature joint protection with prefabricated galvanised steel joint profile of 150 mm depth of Signature joint manufactured by Permaban UK or equivalent 183 Mtr
81 1.08 Isolation Joint: Providing Isolation Joint in floor with PU pad of 12 mm thick and Saw cutting the Joint for a width of 12 mm and Depth of 20 mm and filling the gap 12 mm X 20 mm with Polysulphide sealant, backer rod, labours, materials etc., all complete . 808 Mtr
82 1.081 Column Auxillary Reinforcement:- Providing and fixing of reinforcement around the columns with 5 Nos of 1.20Mtr length 8 mm dia @ 100mm c/c as per the drawing. 690 Kgs
83 1.082 Polishing & Densifications:- Using Polishing machine with different grit of diamond tools to get Smooth finish and Densifiying the floor with approved chemicals. Surface Hardening ( Concrete Densification ) using Lithium Densifier in uniform quantity ( 6 Sqm Per liter approx.) including preparation of surface by removing dirt, layer of curing compound by wet ( water ) grinding, cleaning with a mechanical scrubber or soft broom to allow maximum penetration of the liquid and get non porous dust free surface etc complete" 10312 Sqm
84 1.083 \nToilet Waterproofing\nSupplying and installation of two component, Polymer modified waterproof coating Fosroc Brushbond RFX seamless, elastomeric water-proof coating.\na) Surface Preparation:- The cleaning and preparation of the substrate to which Fosroc Brushbond RFX is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Greese, oil and other contaminants which may impair adhesion must be removed prior to the application. Surface shall be maintained in SSD condition before applying waterproof coating.\nb) Coving at Right Angle Junctions:- All the right angle junctions between floor and wall shall be provided with coving of size 75mm x 75mm minimum 15mm thickness in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with Nitobond SBR.\nc) Down Take Pipe Packing:- The pipes to be fixed should be filed in order to provided a proper bond and the same to be alligned by the respective agency. The annular space around the drain pipe shall be packed using Conbextra GP2, a high strength free flow non shrink grout mixed with water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR on the core surface fixing leak free form work as per manufacturer's specification. \nd) Pressure Grouting at Leaking points:-Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg of cement including joints packing using polymer modified mortar. Fixing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification\ne) Waterproof coating:- Providing and applying waterproof coating using Brushbond RFX at 1mm thick in 2 coats at a coverage rate of 12 - 14 sqm per 20.88kg bag with interval period of 6 hours over a substrate with Saturated Surface Dry condition. Termination to be done on wall extending the coating to min.300mm height above the finished floor level and sealed in the termination groove of 20mm wide and 10mm deep flushed with polymer modified mortar as per vendor recommendation. The applied material of Brushbond RFX should have a weight loss of less than 1gm when tested for abrasion resistance according to ASTM-D4060,Tensile strength as per ASTM D638 is 2N/mm² Adhesion to concrete is greater than 1N/mm² and static crack accommodation of 1mm according to ASTM-C836.\n 2484 Sqm
85 1.084 \nProtective Plastering for the above item:- Fine sand shall be sprinkled while the coating is in tacky condition. Providing and laying plastering of 12mm thickness in CM 1:4 mixed with integral waterproofing compound Conplast WL @ 150ml per bag of cement. System include necessary preparation, curing with water, chemicals used, labour, etc as per specification complete\n 2484 Sqm
86 1.085 \nRainwater Collection pit Waterproofing \nSupplying and installation of two component, Polymer modified waterproof coating Fosroc Nitocote CM 210 seamless, elastomeric water-proof coating.\na) Surface Preparation:- The cleaning and preparation of the substrate to which Fosroc Nitocote CM 210 is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application. Surface shall be maintained in SSD condition before applying waterproof coating.\nb) Coving at Right Angle Junctions:- All the right angle junctions between floor and wall shall be provided with coving of size 75mm x 75mm minimum 15mm thickness in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with Nitobond SBR.\nc) Down Take Pipe Packing:- The pipes to be fixed should be filed in order to provided a proper bond and the same to be alligned by the respective agency. The annular space around the Rain water pipe shall be packed using Conbextra GP2, a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR on the core surface fixing leak free form work as per manufacturer's specification. \nd) Pressure Grouting at Leaking points:- Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. FIxing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification\ne) Waterproof coating:- Providing and applying Fosroc Nitocote CM210, an elastomeric cementitious coating. System shall consist of two-component polymer modified cementitious coating mixed on site using a slow speed drill fitted with a mixing paddle and then applied to the substrate using a trowel for best results. The product shall be applied in 2 layers to achieve the DFT of 2mm. Coating shall be applied to the entire surface of floor and wall. The cured coating, after immersion, shall be capable of withstanding cracked substrate cyclic movement from 0 - 300 - 0 microns at 15°C for 6,000 cycles without failure. It shall have the capability to resist a positive water pressure of 5 bar and a negative water pressure of 3 bar when tested to European standard CEN/TC 67-67072:2003 part A-7.complete as per manufacturer's specification, approved drawings, as specified and as directed by Engineer, at all levels\n 7557 Sqm
87 1.086 \nProtective Plastering for the above item:- Fine sand shall be sprinkled while the coating is in tacky condition. Providing and laying plastering of 12mm thickness in CM 1:4 mixed with integral waterproofing compound Conplast WL @ 150ml per bag of cement. System include necessary preparation, curing with water, chemicals used, labour, etc as per specification complete\n 7557 Sqm
88 1.087 \nARCHITECTURAL WORKS\n
89 1.088 \nMASONRY WORKS\n
90 1.089 \nProviding and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar using 30kgs/cum of masonry all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). \n
91 1.09 Ground Floor 1051 Cum
92 1.091 Ground floor Mezzanine 708 Cum
93 1.092 First floor 919 Cum
94 1.093 First floor Mezzanine 714 Cum
95 1.094 Terrace floor 79 Cum
96 1.095 \nExtra rate over & above Solid Masonry wall for providing RCC Binder 80 mm thick with M20 Grade reinforced cement concrete using coarse graded aggregate of 12 mm and downsize, reinforced with 4 Nos of 8 mm dia Fe500 grade steel and 6 mm dia Mild steel stirrups at 200 mm c/c and binders placed at intervals not more than 1000 mm, including cost of reinforcements and tying in position using binding wire made out of 18 gauge GI annealed, form work, scaffolding, all labour, hire and fuel charges for all tools and plants employed and all other incidental charges etc. all complete, as directed, in 150mm thick walls.\n
97 1.096 Ground Floor 1220 Mtr
98 1.097 Ground floor Mezzanine 806 Mtr
99 1.098 First floor 1169 Mtr
100 1.099 First floor Mezzanine 800 Mtr
101 1.1 \nProviding and applying 10mm thick ceiling plaster including Staircase waist slab in cement mortar mix ratio CM 1:3 (1 cement : 3 River sand), to internal surfaces of concrete work; including hacking concrete surfaces then applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate, preparing grooves, pattas, wattas, rounding of corners, etc. all complete as per architectural drawings, specifications and finished smooth with wooden rundha etc. or as specified; at all leads, depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces, curing, etc. complete as per specification and to the approval of the PMC/Employer.\n
102 1.101 Ground floor 2218 Sqm
103 1.102 Ground floor Mezzanine 273 Sqm
104 1.103 First floor 703 Sqm
105 1.104 First floor Mezzanine 273 Sqm
106 1.105 \nInternal Plastering:- Providing and applying 15mm thick plaster in cement mortar mix ratio CM 1:4 ( 1 cement : 4 River sand ), to internal surfaces of concrete and masonry work; including raking out joints, hacking concrete surfaces and applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate; also providing and fixing 20 gauge GI chicken mesh @ 150 mm wide to junctions of concrete and masonry, preparing jambs, sills, grooves, bands, wattas, rounding of corners, etc. all complete as per architectural drawings, specifications and finished smooth with wooden rundha etc. or as specified by the PMC/Employer at all leads, depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces, curing, etc. complete as per specification and to the approval of the PMC/Employer. ( Location: Internal wall surfaces and behind wall dado )\n
107 1.106 Ground floor 13597 Sqm
108 1.107 Ground floor Mezzanine 10618 Sqm
109 1.108 First floor 9674 Sqm
110 1.109 First floor Mezzanine 10618 Sqm
111 1.11 Terrace floor 1003 Sqm
112 1.111 \nExternal Plastering:- Providing and applying minimum 18mm thick double coat cement sand plaster; first coat to be 12mm thick cement sand mortar of mix ratio CM 1:5 (1 cement : 5 River sand) including adding 2% by weight of cement approved waterproofing compound of approved manufacturer, second coat to be 6mm thick in cement sand mortar of mix ratio CM 1:3 ( 1 cement : 3 River sand ), finished sand face or as required to receive specified architectural external finish to correct line, plumb and level to external faces of walls, sofits/ceiling if any, including hacking concrete surfaces then applying chemical adhesive coating and a scratch/dash coat as a positive bond, curing the same, racking out junctions of masonry and concrete, then pointing and grouting using non-shrinking compound, joints grouted by pressing square crushed stone, further providing 150mm wide 20 gauge GI chicken mesh at junctions of concrete and masonry work, doing independent double legged scaffolding etc.\nItem also include necessary scafolding, plastering to window sills, RCC cornices, making wattas, drip-moulds, bands, grooves etc., doing curing, cleaning, etc. all complete to the approval of the PMC/Employer. ( To External Surfaces )\n 13921 Sqm
113 1.112 \nMarble Flooring:- Supplying and laying 18mm ( + )1mm thick approved Italian marble flooring of specified size and pattern laid over 20mm thick Cement sand mortar ( M-Sand )1:4 bed with a layer of White cement slurry topping over mortar. Marble floor joints shall be filled using epoxy based grouting material of matching colour including all other necessary related works, cleaning, all leads & lifts, etc complete and as specified in the drawings, specifications and as directed by Engineer-in-charge. Rate shall include wastages, necessary coats of polishing to the satisfaction of PMC/Employre and necessary floor protection with 400 micron transparent polythene sheet with 10mm thk POP over lay till hand over. ( Basic price Rs.260/Sft ) Location:- Ground floor & First floor Air-Conditioned Lobby \n 3418 Sqm
114 1.113 \nGranite Flooring:- Providing and laying 18mm ( + )1mm thick approved machine cut, machine polished Granite stone flooring in pattern and size as detailed in drawing or as directed by the PMC/Employer. Stone to be bedded over minimum 20mm thick cement sand mortar mix ratio 1:6 (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, joints to be cleaned and grouted with matching colour approved quality polymer based readymade grout (Bal or Laticrete or equivalent approved), wastages, curing, cleaning, polishing to required line, level, protecting till handing over etc. all complete at all heights and leads to the satisfaction of the PMC/Employer. (Note: Supplying of Granite should be from Tamil Nadu Mines and Minerals approved Licensed quarry) ( Basic Price Rs.140/Sft ) Location:- Ground floor & First floor Non - Condioned Lobby, Pre-function lobby, Business Centre \n 4543 Sqm
115 1.114 \nCarpet Flooring:- Providing and laying of Carpet Tile over the specified area with following specification. The floor which recieves the carpet to be thourougly cleaned as per manufacturer's specification. The carpet is to be laid over a bed of manufacturer's approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include Supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns thickness, held together with scotch tape. The laid carpet to be vacuumed after the removal of protective cover/on commissioning. If after the protective layer is removed and stains observed in the carpet because of in adequate protection, the same shall be shampooed and made good to the satisfaction of the project managers. The measurements of carpet will be the actual laid area. ( Basic Price Rs.140/Sft ) Location:- First floor Convention Hall & Conference Hall \n 5447 Sqm
116 1.115 \nVitrified Tile Flooring:- Providing and laying approved first quality, colour, design and shade Vitrified Tiles 600mm x 600 x 10mm of approved make (conforming to IS 15622, water absorption less than 0.05%) flooring in pattern as detailed in drawing or as directed by the PMC/Employer. Tile to be bedded over minimum 20mm thick cement sand mortar mix ratio 1:6 (1 cement : 6 coarse sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 Kg/Sqm over cleaned surface and spreading neat cement paste using minimum cement about 4.5 Kg/Sqm over cement mortar bed, joints to be cleaned and grouted with matching colour approved quality ploymer based readymade grout, curing, cleaning, to required line, level, protecting till handing over including wastages all complete at all leads, lifts and heights to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.60/Sft ) Location:- Toilets, Disaster Management, Medical centre, AV room, Pantry\n 7140 Sqm
117 1.116 \nProviding and laying Granolithic flooring (Cement Flooring) of 80mm thick with cement concrete 1:1.5:3 ( 1 cement : 1.5 M- sand : 3 graded stone aggregate ) using 20mm hard broken stone aggregate laid to level or slope in bays not exceeding 3 sqm per panel including providing metal/glass strips to the full depth of the flooring and finishing the top with rubbed, smooth with power trowel, thread lining, curing, including all leads and lifts in all levels etc; complete all as per standard specifications. (The rate is inclusive of necessary planking for panelling wherever necessary as directed by the PMC / Employer) Location:- Electrical room, Furniture storage, Compressor, AHU room, Convention & Conference Halls\n
118 1.117 Ground floor 1349 Sqm
119 1.118 Ground floor Mezzanine 3107 Sqm
120 1.119 First floor 8234 Sqm
121 1.12 First floor Mezzanine 3092 Sqm
122 1.121 \nProviding and laying 18mm ( + )1mm thick approved machine cut, machine polished Granite stone flooring in Treads & Riser as per drawing or as directed by the PMC/Employer. Treads in one piece or as directed to full length of step to be rounded at front and all exposed edges machine polished. Further treads to have 2 nos of 5mm x 5mm deep grooves on top at front or as detailed in drawing. Treads & Riser to be bedded in cement mortar minimum 20 mm thick mix ratio 1:6 (1 cement : 6 M-sand) including preparing and cleaning surfaces, spreading cement slurry using minimum cement 2 kg/sqm over prepared surface and 4.5 kg/sq m over bedding, joints to be cleaned and grouted with matching colour approved readymade grout, curing, cleaning, polishing (machine/hand polishing again if required by PMC/Employer) all complete at all heights and leads to the approval of the PMC/Employer. (Note: Supplying of Granite should be from Tamil Nadu Mines and Minerals approved Licensed quarry) ( Basic Price Rs.180/Sft ) Location:- Entrance Steps & Fronside Staircase\n 1148 Sqm
123 1.122 \nProviding and laying 25mm thick machine cut, machine polished approved Kota stone flooring in Treads & Riser pattern and size as detailed in drawing or as directed by the PMC/Employer. Stone to be bedded in 20mm thick cement mortar 1:6 (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, to required line, level; joints to be cleaned and grouted with matching colour approved quality readymade grout, curing, cleaning, polishing, protecting etc. all complete at all heights and leads to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.35/Sft) Location: Service Staircase Tread, Riser & landings)\n 1141 Sqm
124 1.123 \nProviding and fixing of Aerocon Panels (Exterior Grade) of size 3000 x 600 x 75mm thick installed on 0.8mm thick GI Channels fixed at top and bottom with necessary accessories panels fixed on to it with tongue and groove joint locking and finished with USG Boral jointing compound & tape etc., including trasportation, loading, unloading, leads and lifts at all levels complete., all as per approved drawings. ( Note: Rate is inclusive of one Coat Primer & Wherever Putty Required )\n 8019 Sqm
125 1.124 \nProviding and fixing of Aerocon Panels (Exterior Grade) of size 3000 x 600 x 50mm thick installed on 0.8mm thick GI Channels fixed at top and bottom with necessary accessories panels fixed on to it with tongue and groove joint locking and finished with USG Boral jointing compound & tape etc., including trasportation, loading, unloading, leads and lifts at all levels complete., all as per approved drawings. ( Note: Rate is inclusive of one Coat Primer & Wherever Putty Required )\n 2757 Sqm
126 1.125 \nProviding and cladding of Italian marble slab of thickness 20mm ( + 1mm) thick best quality marble of size as per drg. using dry fixing method. Each slab is to be individually supported using 4nos of stainless steel clamps, two each at top and bottom with SS clamp will be of size as per site condition to achieve on overall depth of 40 to 45mm (Including thickness of stone. Each SS clamp will be fixed to the wall using two numbers of MS oxidized non-corrosive expansion anchor fasteners of size 10mm head, 6mm dia, 100mm length for masonry work and 10mm head, 6mm dia, 50mm length for RCC areas. Each marble slab will have two SS clamps at the bottom with the lipping of 12mm height embedded in the groove cut in the marble and the groove depth being 20mm and width being 5mm.The Bottom row of slabs shall be packed with cement mortar additionally. Structural steel support work wherever required shall be measured seperately. ( Basic Price Rs.260/Sft ) Location: Main Lobby Lift, Column and Prefunction lobby\n 1040 Sqm
127 1.126 \nProviding and fixing 6mm thick Mirror of approved make with 12mm thick marine grade plywood (conforming to IS 710) backing and teakwood beading (anti-termite treated, kiln seasoned) on four sides, including necessary SS (304) studs, beading to be finished with melamine polish in approved shade, etc. complete to entire satisfaction of the PMC/Employer. Location:- Main Lift Lobby\n 61 Sqm
128 1.127 \nVitrified Tile Cladding:- Providing and fixing approved first quality, colour, design and shade Vitrified Tiles 600mm x 600mm x 10mm of approved make (conforming to IS 15622 and EN 176 and water absorption less than 0.05%) dado to walls/columns, as shown in drawing or as directed by the PMC/Employer. Tile fixed over pre-plastered (12mm thick) masonry / RCC surfaces by using approved compatible adhesive (Bal / Laticrete or equivalent approved) over plastered surface to correct line, level and plumb. Joints are well cleaned and grouted with matching colour polymer based approved quality readymade grout and cured, cleaned, junctions with plaster finished smooth, etc. all complete at all heights and leads to the satisfaction of the PMC/Employer. ( Basic Price Rs.60/Sft ) Location:- Toilets, Pantry\n 2411 Sqm
129 1.128 \nVitrified Tile Cladding:- Providing and fixing approved first quality, colour, design and shade Vitrified Tiles 600 x 600mm x 10mm of approved make (conforming to IS 15622 and EN 176 and water absorption less than 0.05%) dado to walls/columns, as shown in drawing or as directed by the PMC/Employer. Tile fixed over pre-plastered (12mm thick) masonry / RCC surfaces by using approved compatible adhesive (Bal / Laticrete or equivalent approved) over plastered surface to correct line, level and plumb. Joints are well cleaned and grouted with matching colour polymer based approved quality readymade grout and cured, cleaned, junctions with plaster finished smooth, etc. all complete at all heights and leads to the satisfaction of the PMC/Employer. ( Basic Price Rs.90/Sft ) Location:- Hall Entry at Ground & First floor\n 3167 Sqm
130 1.129 \nProviding and fixing Toilet cubicle Classsique Floater Cubicles are toilor-made for restrooms. These Cubicles shall have a clear floor concept which shall be very friendly as far as the maintenance is concerned. These cubicles shall be easily install due to their contemporary designs. To enhance the exquisiteness, all doors are 12mm thick and their stainless steel hardware fittings of approved makes. \nColour of Cubicles : As Per the Greenlam Sturdo Shade Card - Suede Finish \nSize of the Cubicles : 1000mm (Width) * 1500mm (Depth)\nDoor Size : 600mm * 1785mm\nDivider Height : 1820mm\nThickness of Compact Laminate : 12mm\nOverall Height of Cubicle : 1995mm (Including Bottom Gap 150 mm)\nAccessories: Standard – Aluminium, Nylon accessories\na) Nylon Adjustable foot\nb) Nylon Thumb Turm Indicator\nc) Nylon Gravity hinges\nd) Nylon Coat Hook\ne) Nylon Door Knob\nf) Aluminum U Channel\ng) Aluminium Door Stopper Channel\nh) Aluminium Top Rail \ni) Screws, Wall Plugs & Noise Tape\n 126 Nos
131 1.13 \nSTACKABLE PARTITION:- Supplying and fixing of Stackable Partition of approved make System with standard Vertical Panels and 2 Adjustable telescopic Panel. Frames & Tracks are made of clear anodized aluminium. The frame must be cladded either side with 16mm thick quality MDF board panels hung in acoustic isolation from the frame and allowed to vibrate independently of the frame. The face panels must be easily removable. The panels must be filled with Acoustic Material Rockwool of High density 45Kgs / Cum and Damping material fo 4mm 8Kgs/Sqm to achieve acoustic sound insulation of 45DB. Each panel to have top and bottom rubber retractable seal with concave/convex vertical interlocking profiles. Each panels to be suspended (Single suspension) by Counter Rotating roller carriers to allow panel for the suitable stacking. The rollers must be connected to the element via a shock absorbing mechanism. The individual element must be adjustable in height without opening of the ceiling. Rate is inclusive of 1mm thick laminate of VIR/Merino or equivalent as approved shade as directed by Architect. (Note: Contractor should study the structural Beam drawing and should submit the shop drawing. Rate to include Necessary MS Support structures for suspension and Gypsum Baffeling charges for Side covering and 1mm thick laminate as approved by Architect). The item shall be generally executed as detailed in Drg. No. TMA / CTC / GFC / ARCH / A-18A / R0.\n 1749 Sqm
132 1.131 \nHALL ACOUSTIC:- Providing and Fixing Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by the Architect/ approving engineer, made of a high density fibre board with minimum 725 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.52. The panels shall be mounted on special aluminium splines using clips provided by Manufacturer and approved by the Architect/ Engineer-in-Charge.\nInstall wooden battens of section 50x50mm or as approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks provided by manufacturer over the lowest and second wooden batten at an on-centre distance of 600mm. Install the Skirting of width 50mm or more as required by the Architect/ Engineer-in-Charge and insert the tongue end of the panel in the skirting. Place the inside clip on the groove end of the panel along the Al keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour. Installation to be carried out by approved Vendor Trained Installation team & Installation should be carried out as per manufactuer recommended procedure. Location: Exibhition Hall and Convention hall inner cladding\n 4172 Sqm
133 1.132 \nSupplying and fixing of 50mm thick glass wool of 16kgs/cum density wrapped in white tissue and placed in the cavity of the Anodized Aluminium frame work and wood works panel for sound absorbtion.\n 4172 Sqm
134 1.133 \nSupplying and fixing of un anodized Aluminium frame work using 50x25mm of 1.2mm thick Aluminium box section @ 900mm interval vertically and 600mm interval horizontaly.\n 4172 Sqm
135 1.134 \nSupplying and fixing of Aluminium anodised 'T' Profile in all Horizontal joints matching wall panel colour.\n 1070 Mtr
136 1.135 \nSupplying and fixing of wooden beading of size 35mm x35mm polished with Mellamine Matt finish matching to the wall panel colour.\n 2086 Mtr
137 1.136 \nSupplying and fixing of 9mm thick acoustic (Ecopanel) panelling formed and to be fixed using adhesives as per the manufacturer specificaiton of weight 2Kgs/Sqm and composition of 100% PET (60% Recycled) with B1 FR Rating of size 1200mm x 2400mm ( + 2mm) with sound absorption rating 0.84NRC Location: Exhibhition and Conference Hall inner cladding\n 5433 Sqm
138 1.137 \nProviding and Fixing of Multi cell Polycarbonate Panels 10 mm thick with 3 cells - 4 walls structure over MS Supporting structures. Panel Width shall be 600 mm to ensure best performance for wind uplift.\nPanels having Vertical Standing Seam 15mm at both sides; snap-on Aluminium connector to interlock the panels shall have a grip-lock 2 tooth locking mechanism to ensure maximum uplift capability. Panels shall be fixed on the structure using Aluminum connector. The panels shall be uniform in color with an integral Multi-Cell core. In a cross section, the core shall be constructed of Microcell of max 4.5mm x 4.5mm. Panels shall be manufactured with approved quality assurance as per ISO 9001 & ISO 14001 and manufactures should have successful project reference having minimum 1500 sq mtr in Indian subcontinent at least for 15 years old. Location:- Main lobby front wall and Pre-function lobby cladding\n 1199 Sqm
139 1.138 \nProviding and fixing 1mm thick laminate panelling using 12mm thick waterproof marine plywood boards of approved make and conforming to IS 3087; fixed on Aluminium framing of size 50mm x 38mm at every 900mm c/c vertically and 600mm c/c horizontally. Aluminium framing to be fixed and anchored to walls at top and bottom using SS anchor fasteners. Pattern of panelling shall be as indicated in drawings with extra bands as required thickness to be provided so as to produce dubbed / raised panel as required all complete as per Architectural drawings and to the entire satisfaction of PMC/Employer. ( Location: Pre-funtion Lobby Cladding )\n 120 Sqm
140 1.139 \nProviding and fixing 12mm thick Toughened Glass partition Glazing of height 6.50mtr using SS Spider Point fixing system ( DORMA or equivalent ) with . 21.52mm thick Laminated Glass Fins 450mm wide to be provided from ground floor to ceiling to support 6.50mt high glazing. The system to be designed to withstand wind pressure of 1.5kpa. Provision to be made to provide 2400 x 2400mm Door in the glazing system. Total height of the system to be divided in 3 panels of size 2700mm + 1900mm + 1900mm with width of panel upto 1510mm. Bottom glass panel to be supported in U channel grouted in ground floor. The complete glazing to be aligned and levelled. The gaps between two glass to be filled with silicon weather sealant (DC 789 or equivalent).\n 457 Sqm
141 1.14 \nGypsum Partition at Conference Hall:- Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.\n75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum board conforming to IS:2095: part I\n 1742 Sqm
142 1.141 \nFALSE CEILING BAFFLE CEILING SYSTEM – 0.7 MM GI PLAIN, WOOD GRAIN FINISH Providing and Fixing Suspended Metal Baffle Ceilings manufactured in Hook-on system (V-P 500) with Rectangular vertical panel blades made out of 0.7mm thick GI in height of 150mm, widths of 50mm, length of 2400mm. General Specifications:Entire system to be designed in accordance with EN 13964 and TAIM e.V. quality guidelines suitable for Green Building Application for exterior applications, with visible Grid, and connected panels with approved on-centre spacing.\nPanel Specifications: The V-P 500 rectangular Hook-On vertical baffle panels to be made of Galvanized Iron (GI), minimum thickness 0.7mm, 120gsm hot dipped galvanization (both sides), and recycled content of 25%. The panel Length to be 2400mm, panel Widths of 50mm, panel Heights of 150mm, with straight vertical edge having hairline visuals with adjoining panel. The panel surface to be powder coated (post coat) to 60-80µ on visible side after mechanical production, low gloss (degree of gloss approx. 20%). Scrubbable, architectural-quality, electrostatically applied polyester powder coat paint applied to entire panel after forming (post coat). Panel coated on both sides for exterior application. The color to be approved Wood Grain finish (Epoxy Polyester for Interior). The panels to be unperforated plain finish, without having any acoustical Inlay. The panels to be Non-accessible, with system height of 42mm+blade height, and would require a plenum height of a minimum 450mm clear space from bare ceiling / rigid structure.\n
143 1.142 \nThe Fire performance to be Material class A2-s1.d0 according to EN 13501-1 for the metal ceiling panel made of Galvanized Iron, with a powder coating on one side (visible side) with or without inlays. Suspension System Specifications: Primary Runners would be GI U-Profile (black) of 30mm(H) x 3746mm(L) x 20mm(W) x 1.5mm(T), roll formed slotted profile. Accessories would include Hanger for vertical baffle (black, GI), U-Profile Splice (GI), Universal Wall Anchor (GI), Plug-in Clip (spring steel), Distance Holder (spring steel), Connector for vertical baffle (GI), Clamping Bracket (GI). Suspension (normal) would be M6 GI threaded rod (2000mm L) / 2.5mm GI hanger wire (2000mm L). Suspension (wind load) would include compression struts (GI), 38mm deep, 16Ga., cold rolled steel C-channels, 2.68mm GI hanger, splay wire (2000mm L).\nInstallation Specifications: Primary runners Installation: U-Profiles (black), spaced at 1200mm, to be suspended from ceiling using clamping brackets and threaded rods OR hanger wires. Hanger wires must be wrapped tightly with 3 full wraps. The Hanger for vertical baffle shall be located and fastened to the U-profile to the matching square slots at the required on-centre spacing, using plug-in clips. If the pitch distance of the Baffles doesn’t fit with the modulation of the U-Profile (steps of 25mm), the Locking Clip needs to be inserted into a long hole, and the hanger position should be fixed by using a pop-rivet or self-drilling screw. The U-profiles to be fastened to two adjacent walls using the wall anchor and bolts. U-Profiles to be at a maximum distance of 450mm (max.) to a perimeter wall or outside edge of a floating module. To join two pieces of continuous U-profiles, a U-Profile splice to be used. Panel Installation: The V-P 500 rectangular Hook-On vertical baffle panels to be slightly opened and hooked on to the Hangers for vertical baffles (in accordance with the shop drawings). Two panels to be joined together using Connector for vertical baffle. Field-cut Panels: Perimeter panels that require field cutting to create openings / voids for services, must be done in accordance with the cutting instructions provided by the manufacturer. All mechanical services to be independently suspended. For an Interval of 200mm C/c of each baffle - Location:- Hall Entrance lobby Non Air conditioned\n 2690 Sqm
144 1.143 \nProviding and fixing in true horizontal level Open cell GI lay-in ceiling tiles with border panels forming flush-tegular edge of size 600mmx600mmx38mm having Fire Performance CLASS A1 (EN13964). The tile of ‘Global white’ color with cell size 200mm X 200mm shall be laid on white painted XL15mm profile grid system comprising Main runners (3000mm), 1200mm and 600mm cross tees with 15mm white flanges and 32mm web height. The grid should be make with 15mm wide T - section flanges color white having rotary stitching on all T sections i.e. the Main Runner with C3 coupling, 1200 mm & 600 mm Cross Tees with Hardened XL2 Clip having a web height of 38 mm and a load carrying capacity of 7 Kgs/M. The T Sections have a Galvanizing of 90 grams per M2 with pull out strength of 100 Kgs. To comprise main runner spaced at 1200mm centers securely fixed to the structural soffit by approved hangers at 1200mm maximum centre & not more than 150mm from spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from the adjacent wall. 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long cross tees centrally between the 1200 mm cross tees. Perimeter trim wall angles secured to walls at 450 mm maximum centers. Accessories should consists of M6 Anchor Fasteners with Vertical Hangers made of Galvanized steel Galvanized Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.65 mm of 1.8 m length., thickness of 80gsm and a tensile strength of 344-413 MPa Location:- Exhibition Hall\n 11914 Sqm
145 1.144 \nProviding and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and directionof the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I ( Location: Main Lobby, Convention Hall & Conference Hall )\n 13939 Sqm
146 1.145 \nProviding and installing suspended ceiling system at all levels with interlocking grid of size 595x595mm ceiling module of size (600x600) consisting of demountable infill units (size 600 x 600 X 0.6 or 0.7mm) having 50mm gap at every 1200mm, gap covered with 82mm wide channel having flanges to hold ceiling panels. The ceiling shall be powder coated (PVDFPPC,80micron) one xposed and unexposed surface with approved colour. in true horizontal level suspended on interlocking metal grid of hot dipped galvanised steel sections consisting of main 'T' runner suitably spaced atjoints to get required length and of size24x38mm made from 0.33mm thick sheet, spaced1200mm centre to centre, and cross "T" of size 24x28mm made out of 0.33mm sheet, 1200mm long spaced between main 'T' at 600mm centre to centre to form a grid of 1200 x 600mm and secondary cross 'T' of length 600mm and size 24x28mm made of 0.33mm thick sheet to be interlocked at middle of the 1200x600mm panel to from grid of size 600x600mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size (24x24X3000mmmade o f0.40mm thick sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval. \nProviding and laying 6mm thick calcium silicate ceiling tiles of plain in the grid including, cutting/making opening for services liked iffusers, grills, lightfittings, fixtures, smokedetectorsetc. wherever required, Main 'T' runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I.adjustable rods with galvanised steel level clips of size 85x30x0.8mm, spaced at 1200mm centre to centre along main 'T', bottom exposed with 24mm of all T-sections shall be pre-painted, for all heights, drawings and as directed by engineer-in-charge. Location:- Toilets, Disaster Management, Medical centre, AV room, Pantry\n 1753 Sqm
147 1.146 \nSupplying and fixing of 10mm thick Danpolan Multicell Paneling of size 11980mm x 900mm with standard Accessories like PC Connectors, Spacer, screws, end cap, UPD and Tape( Colour:- Clear + PRL LOW E (IR) Location:- Pre-function lobby (Rate is inclusive of Ceiling suspension system )\n 72 Sqm
148 1.147 \nJOINERIES\n
149 1.148 \nWooden Acoustic Door: \nProviding and fixing approved make Wooden acoustic Main door of Single/Double leaf, 86 mm thick sandwich type composite sound reducing flush door shutter including Hardwood door frame, comprising as per following details:\n(a) Door frame shall be of hard wood of size - 150 mm X 125 mm, including making necessary grooves for fixing of hollow bulb type EDPM gaskets on rebates / Or Corner seal to block noise leakage from gap in between door frame and shutter. The frame shall be properly finished, sanded and polished with 3 or more coats of melamine polish as per\napproved shade, finish and specifications.\n(b) The frame of door shutter shall be made from 24 mm thick hardwood wood stiles at top & bottom rails , Lock rail 100 mm wide and 24 mm thick and three additional strips 50 mm wide and 24 mm thick (minimum)\n(c) The core of door shutter shall be filled with resin bonded Rockwool of a minimum density of 96 kg/cum conforming to IS 8183 and BS 476 Part-II and one sound damping sheet 03 mm thick to increase STC rating of door shutter.\n(d) Face panels shall be of 12 mm thick Commercial ply boards conforming to relevant IS codes on both sides of the core of the shutter.\n(e) The final finish will be 1.0 mm thick laminate /4mm Veneer as per Architect’s choice / approval on both sides . All edges shall be provided with teak wood lipping, margins etc., including melamine polish as per approved specs, finish and shade.\n(f) An Internal Automatic Dropdown Seal of excellent quality of approved make should be provided. This seal should offer resistance to sound up to 45db, air, insects, smoke, daylight; and should be designed for timber (wooden) doors.\n(g) All Supplying of hardware shall be exclusive and fixing of hardware deemed to be included\n(h) Performance :- The design of door will be as per test conduct from CSIR NPL lab , STC Value will be 45 as per IS:9901( Part III)-1981, DIN:52210 Part- VI-1989, ISO:140 (part III) – 1995. Higher STC 56 at 4000hz\nThe Panels filled with Acoustic material Glass wool of 96 Kg/m3 density , 6 MM thick anti donning layer having Thermal Conductivity 0.037 @ 20 C as per EN ISO 8497 (DIN 52613) and 2 mm thick Sound Damping layer MTS 05-303 to achieve higher Sound STC as per site condition.\nDouble Door size - 2400 x 3000mm\n 48 Nos
150 1.149 \nProviding, making and fixing wooden door frames made out of approved first quality teak wood chemicaly treated, Seasoned, antitermite treated, shaped, grooved, mitered joint arrangement, mouldings, rebates, including use of approved water repellent adhesive, GI screws, pins, etc. all exposed surfaces to be melamine polished in approved colour and shade, surfaces of frame in contact with masonry / concrete surfaces shall be painted with one coat of hot bitumen of approved quality, 3 nos. GI holdfast (split and 225 x 75 x 2 mm thick) on each side of frame well-grouted with cement concrete mix in a ratio of 1:2:4 (1 cement : 2 sand : 4 aggregate), etc. complete to the entire satisfaction of the PMC/Employer.\n 7 Cum
151 1.15 \nProviding and fixing factory made 35mm thick solid core flush shutter conforming to IS 2202 (Part - I); Shutter shall be manufactured with exterior quality synthetic adhesive forming marine ply surfaces, internally lipped as manufactured by approved vendor. Further shutter shall be finished both side with 1 mm thick laminated in approved shade and design with hot pressed at factory, edges of shutter shall be provided with 6mm thick teakwood beadings using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with melamine polish, etc. as directed by the PMC/Employer. ( Rate is exclusive of hardware Supplying and inclusive of hardware fixing )\n 201 Sqm
152 1.151 \nABS DOOR / Equivalent\nProviding and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw. The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated. ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm. PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of Stainless steel ball bearing butterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work Design Pre-laminated door\n 68 Sqm
153 1.152 \nProviding and fixing of frameless glass door using approved Make, fittings of top and bottom patch, corner lock, Floor spring, Handle 450mm long 'H' type, glazed with 12mm thick clear toughened glass with necessary items to finish the job. (Rate is exclusive of hardware Supplying and inclusive of hardware fixing) GDD1 - 2400mm x 3000mm\n 86.4 Sqm
154 1.153 \nFD120 Fire rated doors - Painted\nProviding and fixing of Hollow metal Insulated fire rated doors as per IS 3614 part-1, for stability, integrity & insulation. Pressed galvanized steel conforming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire or third party certified or equivavelent lab, for maximum rating of 120mins with 30minutes of insulation, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label conforming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent.\nDoor frame shall be single rebate grooved profile of size 125 x 60mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff.\nDoor leaf shall be 46mm thick fully flush double skin door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density insulation material. Intumescent seals 15x2mm to be provided all around the door in addition to the grooved smoke seal. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door All doors and frames shall be finished Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include Supplying and installation of door, inclusive of Hardware fixing and exclusive of hardware Supplying as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer. Application: Staircase Exit / Lobby Entry / Exhibhition Hall Exit / Electrical rooms / Compressor rooms\n
155 1.154 120Mins Fire Rated Door Double leaf of size : 1500 x 2100 with vision panel (200 x 300)with hardware set # 44 Nos
156 1.155 120Mins Fire Rated Door Single leaf of size : 1200 x 2100 with vision panel (200 x 300)with hardware set # 6 Nos
157 1.156 120Mins Fire Rated Door Double leaf of size : 1500 x 2100 with vision panel (200 x 300)with hardware set # 18 Nos
158 1.157 \nSingle skin automated rolling shutter\nProviding and fixing of single skin rolling shutter. Slats shall be made from galvanised steel 0.8mm (22 guage) as per IS 277 of size 109mm of approved make Hormann or approved equivalent Construction of the slats shall be of 0.8mm thick GI sheet forming to the door height, the bottom edge of the door shall be sturdy aluminum profile for curtain reinforcement, Weather-resistant, flexible EPDM tubular seal for prevention and penetration of dirt and rain. The side guides will be 2mm thick single piece GI guide rail for superior strentch, rubber seals to be provided for smooth and noise free movement. The shutter box shall be Welded standard steel pipe with double flange steel shafts supported by enclosed bearings. Box cover shall be minimum 0.8mm thick steel box casing cover and side guides painted in soft grey color. Motor capacity shall be 1hp for size upto 5000mm x 5000mm, and 3hp for sizes above 5000mm x 5000mm. Connecting volt shall be 220Volt 50Hz 1 phase up to 5000mm x 5000mm, and 415V 50Hz 3 phase for bigger sizes. One unit Push Button Switch (Up, Stop, Down), IP 65. Current rating will be 5 Amp for sizes less than 5000mm x 5000mm, 9 Amp for more than 5000mm x 5000mm size. Vendor should Supplying 16A, 3 pin, industrial male socket with 1Mtr cable along with controller Rolling shutter finish shall be Galvanized and painted in RAL 9002 outside and soft grey from inside Minimum head room shall be 700mm to 1000mm based on door sizes, including motor side 200mm and bearing side 150mm. Rate shall include Supplying and installation of Single skin rolling shutter for Size - 2000mm x 2100mm as per the architectural drawing\n 7 Nos
159 1.158 \nProviding and fixing of double skin Sectional door SPU F42 as per EN Standard Slats Door made of double-skinned, PU-foamed steel sections of 42 mm cross section,100 % CFC-free & made of hot galvanized steel. Door section heights of 625 or 750 mm. Performance characteristics in accordance to EN 13241-1. EN 12424 Resistance to wind: Class 3. EN 12426 Air permeability: Class 2 (without wicket door). EN 13241 Thermal insulation U = 1.0 W/m²K (without wicket door). EN 717-1 Acoustic rating: R= 25 dB (without wicket door). Frame shall be enclosed, moulded angle frame, made of hot galvanised steel with safety track, secured with screws. For application below 3500mm height VU track shall be used and for higher heights H,N type track to be provided. Space of 300mm shall be provided on the motor side and 150mm on the bearing side of the door. The door shall be counter balanced by coated torsion springs, with carrying cables on the side. Safety feature shall include manually operated door using a torsion spring with approved catch safety device and finger trap protection inside and outside as per DIN EN 12604. Sensor controlled safety devices to monitor the bottom edge of the door, instant stoppage and reversing on encountering any obstruction while closing. Complete ready-to-fit shaft operator with cable slack device. Power input (3-phase current: 0.37 kw) with a protection IP rating of 65. Electronic absolute encoder (AWG) for determining the door position shall be provided. Microprocessor control in separate housing with Open-stop-Close membrane push button integrated in housing, miniature lock, adjustable force limit. Self monitoring closing edge safety device (SKS) with optosensors. Connecting cable with CEE male plug in protection category IP44. Emergency hand chain to be provided in case of power failure. Door leaf shall be polyester-primer coated Grey white exterior and interior, based on RAL 9002. Frame and glazing made of anodized aluminium extrusions with a natural finish in accordance with DIN 17611. All further steel parts manufactured from hot galvanized steel Minimum head room shall be N track - 440mm, H track - 700mm and VU track (Door Height + 780) based on door sizes, including motor side 300mm and be aring side 150mm. Rate shall include Supplying and installation of sectional door\n
160 1.159 RS1 - 5000mm x 6000mm 4 Nos
161 1.16 RS2 - 5000mm x 4000mm 2 Nos
162 1.161 \nUPVC Window: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work\n 438 Sqm
163 1.162 \nUPVC Ventilator: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work\n 57 Sqm
164 1.163 \nSupplying of the following Iron Mongeries items\n
165 1.164 Accessories
166 1.165 Lockwood Tubular Lever on Rose with Escutcheons SSS 70 Nos
167 1.166 Lockwood Euro Profile Cylinder Escutcheons SSS 99 Nos
168 1.167 Lockwood 457mm Recessed Timber Flush Bolts SSS 28 Nos
169 1.168 Lockwood Mortice Universal Flush Bolt Ferrule SC 68 Nos
170 1.169 Lockwood 450mm Recessed Aluminium Flush Bolts SSS 108 Nos
171 1.17 Lockwood dia32x1500(C)x1700mm/dia25x45mmS/S 120 Nos
172 1.171 Lockwood Bottom Door Patch to suit Floor Springs SSS 30 Nos
173 1.172 Lockwood Top Door Patch to suit 15 mm pivot SSS 30 Nos
174 1.173 Lockwood Top Patch with 15mm Pivot SSS 20 Nos
175 1.174 Lockwood Adjustable Top Pivot with Cover 10 Nos
176 1.175 Lockwood 150mm x 50mm Rectangular Concealed Fix Flush Pull SSS 81 Nos
177 1.176 Lockwood dia32x1200(C)x1400mm/dia25x45mmS/S 32 Nos
178 1.177 Floor Spring Wooden Door Accessories, Top Pivot & Bottom Arm 122 Nos
179 1.178 Lockwood 200mm x 19mm Standard D Pull back to back in SSS 42 Nos
180 1.179 Lockwood 120mm x 50mm Rectangular Concealed Fix Flush Pull SSS 24 Nos
181 1.18 Enox Sliding Door Kit Max.Door Panel Weight 90kg 12 Nos
182 1.181 Enox Aluminium Inodised Single Top track Non drilled size 3600mm 12 Nos
183 1.182 Rockwood 2660 Door Co-Ordinator in Black Primed Finish 17 Nos
184 1.183 Cylinders
185 1.184 Lockwood 6 Pin - 30 x 30 Cyl / Thumbturn - 70mm Total Length - MK 21 Nos
186 1.185 Lockwood 6 Pin - 30 x 30 Double Cylinder - 70mm Total Length - MK 130 Nos
187 1.186 Lockwood 5 Pin Single Cylinder C4 Profile - 45mm - MK 71 Nos
188 1.187 Lockwood 6 Pin - 30 x 30 Privacy - 70mm Total Length 18 Nos
189 1.188 Door Closers
190 1.189 King Surface Mounted Power Adjustable Door Closer STA-01 HO 18 Nos
191 1.19 Lockwood Surface Mounted Door Closer Power Selectable 2 - 4 (20kg - 80kg) 179 Nos
192 1.191 King Surface Mounted Power Adjustable Door Closer 7 Nos
193 1.192 Exit Devices and Outside Trims
194 1.193 Lockwood Rimlatch Type Panic Exit Device - one point steel with power coating 71 Nos
195 1.194 Lockwood Vertical Rod Type Panic Exit Device - two point - steel with power coating 17 Nos
196 1.195 Lockwood Panic Exit Device Outside Access Device (Lever - No Cylinder) 71 Nos
197 1.196 Lockwood Panic Exit Double Door Strike 35 Nos
198 1.197 Floor Springs
199 1.198 EN SIZE 3-6 300 Kg.((machinewith cover plate & spindle)(AC360+AC269) 100 Nos
200 1.199 EN SIZE 2-4 (machinewith cover plate & spindle)(AC360+AC534) 22 Nos
201 1.2 EN SIZE 2-4 (machinewith cover plate & spindle) 30 Nos
202 1.201 Hinges
203 1.202 Lockwood 4.0 X 3.0 X 3.0- 2 Ball Bearing Button Tipped SSS 304 with Wooden Screws 462 Nos
204 1.203 Lockwood 4.0 X 3.0 X 3.0- 2 Ball Bearing Button Tipped SSS 304 with Metal Screws 537 Nos
205 1.204 Locks
206 1.205 Lockwood Euro Mortice Lock 60mm Backset - Entrance SSS 70 Nos
207 1.206 Lockwood Euro Mortice Lock 60mm Backset - Deadlock SSS 87 Nos
208 1.207 Lockwood Corner Lock suits Euro Profile Cylinder SSS 30 Nos
209 1.208 Lockwood/ ASSA ABLOY Hex Key Security Door Bolt SC 81 Nos
210 1.209 Lockwood Euro Mortice Sliding Door Lockset No Funiture SSS 12 Nos
211 1.21 Keying
212 1.211 Grand Master Keys - Grid Layout will be issued at the time of issue of LOA along with GFC drawing before commencement of work. 5 Nos
213 1.212 Master Keys - Grid Layout will be issued at the time of issue of LOA along with GFC drawing before commencement of work. 30 Nos
214 1.213 Blank Keys 50 Nos
215 1.214 \nSupplyinging, Fabrication and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete ( Location: Main Staircase ) Refer Drawing Nos: TMA / CTC / GFC / ARCH / A - 22A, B&C / R0\n 6040 Kgs
216 1.215 \nProviding, fabricating and fixing M.S. railing work as per drawing out of square bars / class ‘C’ pipes / tees / angles / flats / I sections / channels etc. including providing and fixing GI hold fast as necessary to the of RCC members / brick work, electric welding the joints and grinding smooth the welded joints to give one piece appearance including taking site measurements and preparing shop drawing, getting approval of shop drawing prior to fabrication from the PMC/Employ er, assembly finish with two coats of zinc phosphate primer and two coats of approved make and shade epoxy paint all complete to entire satisfaction of the PMC/Employer. ( Location: Rear Staircase )\n 4932 Kgs
217 1.216 \nProviding and fixing of 13.52mm Thick ( 6mm + 1.52Pvb + 6mm ) Clear Laminated Toughned Glass Handrail using SS Leg with necessary screws, anchor fasteners with Top 50mm Round Handrail with End Cap with necessary hardware's Refer Drawing No: TMA / CTC / GFC / ARCH / A19-AR0\n 70 Mtr
218 1.217 Providing and fixing signages as per Drg. No. TMA / CTC / GFC / ARCH - A10 R0 & A10A R0 as directed by the Engineer in-charge
219 1.218 ST 03 - External Signage with Sheet Metal with LED Lights 1 Nos
220 1.219 ST 04 - Internal Signage Hall ( Nos & Text ) 6 Nos
221 1.22 ST 05 - Lobby Entry ( Nos & Text ) 6 Nos
222 1.221 ST 06 - Internal Welcome Sign 1 Nos
223 1.222 ST 07 - Internal Toilet 7 Nos
224 1.223 ST 08 - Internal Conference Hall ( Nos & Text ) 10 Nos
225 1.224 ST 09 - Internal Conference Hall ( Double Text & Double Nos ) 4 Nos
226 1.225 \nCEILING PAINT:- Providing and applying oil bound distemper of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels. (Rate is inclusive of Scrapping the existing RCC Surface and finishing joints smoothly with putty).\n 13312 Sqm
227 1.226 \nINTERNAL EMULSION PAINT:- Providing and applying Acrylic emulsion paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); over 2 coats of suitable 1mm thick putty of approved manufacturer including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels.\n 43098 Sqm
228 1.227 \nEXTERNAL PAINT:- Providing and applying Exterior Emulsion Paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor) of newly plastered wall surface with ready mixed paint of first class quality and approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., required scaffolding, leads and lifts at all levels.\n 13921 Sqm
229 1.228 \nProviding and fixing Structural glazing (hybrid-semi unitised system) using 15microns electro colour anodised main frame comprising of mullions, transoms, head and cill section, etc) of size 100x55x2mm approximate or equivalent designed to withstand wind pressure upto 150km/hr fixed to RCC slabs using necessary Aluminium / GI angle cleats for slots for adjusting plumb fixed to the RCC/steel member with suitable fasteners, the main frames verticals to span unsupported length of maximum 3m to 4m. The glazed panel is to be made using suitable subframe / glazing section on which galss of approved make, all as per architectural drawing is to be fixed using a combination of double side cross linked polythene spacer tape and structural sealent (GE ultraglaze SSG 4000 or Dow corning 995). The glazed panels after suitable curing in dust free environment is to be fixed on to the main frame from the exterior ( to enable replacement of glass in future) The grooves (12 to 16mm) to be closed with weather grade silicon sealent / EPDM gaskets. The whole system is to be ensured that corrision resistant hardware is used. It should be totally weather proof and permit necessary thermal expansion and contraction and should be able to withstand specified wind loads. The rate should include cost of filler between the floors to have air tight systems. The design should ensure that no Aluminium frame is seen from outside all complete as directed\n 2527 Sqm
230 1.229 Single glass: Using Single Glass 6mm thick ST 136 Reflective HS Glass 2527 Sqm
231 1.23 \nTop Hung Window: Extra rate over & aboe the #item no.1 window item for designing, providing and fixing hardwares for top hung open able outward shutter having Heavy duty point lock with required points based on the window panel size and handle of mccoy make, SS friction hinges of mccoy make or approved equivalent make and as per particular specfication. Rate shall exclude cost for supplying and fixing of galzz and main frame, but include cost of hardwares and sub frame for shutter. System to be designed to with stand design wind pressure and other load parameters specified.\n 22 Sqm
232 1.231 \nProviding and cladding of Granite Cladding of thickness 20mm ( + 1mm) thick best quality granite of size as per drg. using dry fixing method. Each slab is to be individually supported using 4nos of stainless steel clamps, two each at top and bottom with SS clamp will be of size as per site condition to achieve on overall depth of 40 to 45mm (Including thickness of stone. Each SS clamp will be fixed to the wall using two numbers of MS oxidized non-corrosive expansion anchor fasteners of size 10mm head, 6mm dia, 100mm length for masonry work and 10mm head, 6mm dia, 50mm length for RCC areas. Each marble slab will have two SS clamps at the bottom with the lipping of 12mm height embedded in the groove cut in the marble and the groove depth being 20mm and width being 5mm.The Bottom row of slabs shall be packed with cement mortar additionally. ( Basic Price Rs.260/Sft )\n 304 Sqm
233 1.232 \nProviding and Fixing of GRC - Glass Reinforced Cement Concrete elements Screens in approved size, pattern, design shade and thickness of 15mm to 20mm thick as per drawing No:- TMA / CTC / GFC / ARCH / A-17A / R0. The GRC elements shall be made as follow as:-\na) 53 Grade White Portland Cement - J.K/Brila/RKC\nb) The Silica Sand [1.2mm Size Passing Through 150micron Sieve]\nc) Alkali Resistant Roving Fibre from Nippon (ARG-Fibre)\nd) Acyralic Polimer e) Mould Made by FRP/GRP\nTest Reports: Flexural strength Test should be carried out at approved Laboratary by Engineering consultant and to be submitted to the Employer\nThe GRC Screen Flexural strength average L.O.P shall be above or equivalent to 6N/mm2 & M.O.P should be above or equivalent to 15 N/mm2 for tests done on 28 days cured samples.\nManufacturing Process: a) Using Spray Technology Fixing details:\nb) Using Hilti anchor fastners, 125mm depth, 10mm dia thickness.\nStructural steel work supports wherever required shall be measured seperatley.\n
234 1.233 Supplying and Installation of GRC Column as per drawing No:- TMA / CTC / GFC / ARCH / A-17A / R0. 2030 Sqm
235 1.234 Supplying and Installation of GRP / FRP Mural as per drawing No:- TMA / CTC / GFC / ARCH / A-17A / R0. 296 Sqm
236 1.235 \nExternal Works:- Filling including backfilling with approved good quality earth brought under item 1.236 in plinths, area leveling etc. in layers each not exceeding 200mm in depth, breaking clods, watering, compacting each layer with vibratory compactor and at inaccessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content; dressing up embankments; if required, bailing/pumping out of water to keep site dry while back filling complete as per direction and entire satisfaction of the PMC / Employer. \n 55365 Cum
237 1.236 Coveyance Charges towards including loading & unloading for the above item as per the approved source by the Employer within 10 to 20 Kms in radius 55365 Cum
238 1.237 UTILITY BUILDING
239 1.238 STRUCTURAL WORKS
240 1.239 \nExcavation in all kinds of soil, wet or dry (such as clay, Silty Clay, Sandy clay with Medium/High Plasticity and Soft disintegrated rock etc.,) in loose and slushy condition, including demolition of any existing concrete portion with suitable mechanical excavators like Poclain, JCB etc., and manually wherever required, to the required level for foundations, trenches, rafts, plinths, area levelling, etc., to required depth from existing ground level including disposing off surplus excavated material within the site and levelling as per directed by the PMC/Employer if required disposal outside the campus at location designated by Employer. \nCovering the carting/loaded vehicle with plastic / tarpauline so as to avoid fall and spread of any excavated material on road, cleaning vehicle tyres before moving out of site etc complete, maintaining all the related records, bailing/pumping out water to keep the site dry at all times until completion of backfilling; making temporary stepping / sloping, shoring with planking, strutting, sectioning, trimming, dressing of sides, levelling or grading, cleaning, removing and excavating loose pockets and consolidating them by backfilling as directed etc., all complete to all depths, to the satisfaction of the PMC/Employer. All pits shall be properly barricaded at any point of time.\n
241 1.24 All kind of Soil - (Upto 1.50Mtr depth from EGL) 2672 Cum
242 1.241 All kind of Soil - (1.50Mtr to 3.00Mtr Depth) 1336 Cum
243 1.242 All kind of Soil - (3.00Mtr to 4.50Mtr Depth) 1336 Cum
244 1.243 All kind of Soil - (4.50Mtr to 6.00Mtr Depth) 1336 Cum
245 1.244 All kind of Soil - (6.00Mtr to 7.50Mtr Depth) 1336 Cum
246 1.245 All kind of Soil - (7.50Mtr to 9.00Mtr Depth) 790 Cum
247 1.246 \nFilling including backfilling with approved good quality earth in plinths, area leveling etc. in layers each not exceeding 200mm in depth, breaking clods, watering, compacting each layer with vibratory compactor and at inaccessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content; dressing up embankments; if required, bailing/pumping out of water to keep site dry while back filling; costs includes transportation of all materials, labour, machinery etc. complete as per direction and entire satisfaction of the PMC/Employer.\n 1659 Cum
248 1.247 CEMENT CONCRETE WORKS:-
249 1.248 \nProviding, machine mixing and laying Plain cement concrete (PCC) 1:4:8 ( 1 Cement : 4 sand : 8 graded stone aggregate 20mm nominal size ) of required thickness for foundation, rafts, plinth beams, levelling course and all locations, etc. (minimum cementitious content shall be as specified in the IS Code and as approved); including compacting, curing, required shuttering and its removal, dewatering where required and vibrating, cleaning, preparing surfaces, junctions, etc.; complete at all depths and leads as per the drawing and to entire satisfaction of the PMC/Employer. (Note: Using M - sand)\n
250 1.249 Below Raft 123 Cum
251 1.25 REINFORCED CONCRETE WORKS:-
252 1.251 \nProviding, transporting, pumping and laying batched design mixed, controlled concrete of different grade (as specified in the Structural drawings) conforming to (IS 456) with minimum cement content and maximum water cement ratio as per IS or as specified by Structural Consultant including using approved quality admixtures and placed either with pump / manual / lift for following grades of concrete including compacting, vibrating, curing and protecting etc., complete at all lead, lift & heights as per the drawing and to entire satisfaction of the PMC / Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. ( No separate payment will be made by the Employer towards wastage ). ( Note: Using M - sand )\n
253 1.252 M30 Grade Concrete
254 1.253 Raft 1086 Cum
255 1.254 M35 Grade Concrete - ( Sl. No 1.255 to 1.276 )
256 1.255 Shear walls 795 Cum
257 1.256 Columns
258 1.257 Basement floor 59 Cum
259 1.258 Ground floor 121 Cum
260 1.259 First floor 87 Cum
261 1.26 Terrace floor 26 Cum
262 1.261 Post Tensioning Floor Slabs
263 1.262 Ground floor 174 Cum
264 1.263 First floor 158 Cum
265 1.264 Terrace floor 158 Cum
266 1.265 Post Tensioning Floor Beams
267 1.266 Ground floor 106 Cum
268 1.267 First floor 106 Cum
269 1.268 Terrace floor 106 Cum
270 1.269 Non Post Tensioning Floor Beams
271 1.27 Ground floor 38 Cum
272 1.271 First floor 50 Cum
273 1.272 Terrace floor 50 Cum
274 1.273 Staircase
275 1.274 Basement Floor 11 Cum
276 1.275 Ground floor 11 Cum
277 1.276 First floor 11 Cum
278 1.277 FORMWORK:-
279 1.278 \nProviding, fabricating, erecting form work and deshuttering at all levels and places wherever needed/specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles. \n
280 1.279 Raft 131 Sqm
281 1.28 Shear wall at all levels 2936 Sqm
282 1.281 Columns at all levels 1372 Sqm
283 1.282 PT Slabs at all levels 2435 Sqm
284 1.283 PT Beams at all levels 764 Sqm
285 1.284 Non PT Beams at all levels 686 Sqm
286 1.285 Staircase at all levels 193 Sqm
287 1.286 REINFORCEMENT WORKS:-
288 1.287 \nProviding, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786. ( Note:- Authorized Laps, Spacer Bars and Chairs shall be measured for payment )\n 495428 Kgs
289 1.288 POST TENSIONING WORKS:-
290 1.289 \nDesign and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, Supplyinging, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including Supplying of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the PMC / Employer. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Engineer-in-charge \nSupplying & execution of post tensioning work shall be carried out by approved specialized agency, with their own design, equipment, accessories & skilled manpower for satisfactory completion of work as per approved drawings. The contractor shall have minimum 5 years experienced technical staff for proper monitoring, ensuring & certifying the correctness of entire prestressing operations. Prestressing work shall be duly tabulated and report shall be submitted. Item also to include the required scaffolding etc. including marking the PT strand path locations for easy identification etc. all complete to the entire satisfaction of PMC / Employer. Refer Structural Drawing Nos:- 1920002-CTC-SUBSTATION-12 / 13 & 14\n 15 MT
291 1.29 \nRaft Slab Waterproofing:- Supplying and installation of Pre applied Pressure sensitive based HDPE membrane for Raft slab waterproofing\ni. All PCC surface should be free from cavities and projecting nibs. Concrete shall be fairly smooth finished, dry and free from frost, surface laitance and contamination. Surface shall be thoroughly washed with water jet to make the surface dust free. Standing water must be removed to prevent contamination of overlaps and subsequent compromise of waterproof properties.\nii) Providing and laying FOSROC HDPE-P membrane 1.2mm thick over the PCC area.The system should be fully bonded to cast in situ RCC under pressure sensitive property including overlapping of the membrane at corners & laps 75mm along selvedge adhesive and end laps, various tie-ins using double sided adhesive tapes - Fosroc Membrane HDPE Sealaed Tape of 100mm wide. Longitudinal joints, Intermediate, repairing and accidental joints shall be showeled and provided with sanded tapes, complete as per the vendors specification. \niii) All vertical surfaces on pile caps shall be fixed to the internal face of the shuttering sheet fixed with aid of spot bonding or in support with cover block as per manufacturer specification \niv) Termination of the membrane shall be done by extending the membrane to the thickness of the raft concrete by sticking the membrane to the form work using sealed tapes.\nv) Intersection point of raft and retaining slab waterproofing to be provided with HDPE sealed tape which is over laid with Retaining wall waterproofing as per manufacturer specification. \nvi) Fosroc Membrane HDPE - P doesn't demand any protection layer. Hence main reinforcement shall be carried directly upon the waterproofing membrane The system shall be able to withstand all site conditions including flooding, slush formation, temperature variation, alternate heat and cold variations in a day etc. complete and the bonding system shall exhibit complete properties during and post concreting works. The membrane shall be capable of UV exposure without additional protection for a maximum of 56 days prior to concrete pouring. Cost to include necessary protections during construction and mechanical anchorages as required. The termination of the system shall be able to receive another type of waterproofing with necessary junction details compatible with all other systems available in the market.\nThe pressure sensitive HDPE membrane shall have punctureresistance of > 950 N (as per ASTM E 154), hydrostatic head resistance not less than 70m head of water (ASTM D 751), unaffected thermal flexibility < 25°C no crack, elongation min 400%, Tensile strength 27 Mpa (ASTM D412), Peel strength 880N/m (ASTM D903), Puncture resistance >950N. \n 1206 Sqm
292 1.291 \nRetaining Wall Waterproofing\nSupplying and installation of single component, Pitch free polyurethane based Fosroc Nitoproof 600 PF - seamless, elastomeric water-proof coating.\ni. Retaining wall surface shall be made dry, clean, even and checked for soundness. Removal of oil, dirt, laitance and other contaminants by manually and surface shall be fairly smooth finish. \nii. Filling of tie rod holes if any using Conbextra GP2 mixed with water in ratio 0.16 \niii. Injection grouting of construction joints and honey combs with cementitious pressure grouting with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. \niv. Shamfering the floor wall junctions with cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement.\nv. Providing and applying waterproof coating using Nitoproof 600 PF, Pitch free Elastomeric Polyurethane coating over dry sruface at 1.5mm thick in 2 coats with interval period of 6 hours using spray / squeegee / roller / brush. The product shall be near zero-VOC, eco-friendly, single component liquid membrane.\nvi. Termination to be done on wall extending the coating to min.300mm height above the finished road level as per vendor recommendation.\n 1227 Sqm
293 1.292 \nProtection board for Waterproofing - On completion of membrane application, providing and fixing of High compressive strength (not less 200Mpa) Dimple Board of 8mm thick as protective medium before soil filling.\n 1227 Sqm
294 1.293 \nConstruction Joint / Starter Joint Treatment - Providing, Supplyinging, fixing and treating of construction joints/control joints, settlement joints etc as specified using single component, self sealing water swelling bars Supercast SW 20 made up of flexible polymer composites at joints of retaining walls and water retaining structures,foundations,floor slabs etc and wherever specified with proper overlaps at joints and over adhesive layer of Supercast SWX as per consultants approval at all levels as per drawings.\n 2370 Mtr
295 1.294 \nWaterproofing of Fire Water, Raw Water, Treated Water, RO Tank, etc\nSupplying and installation of two component, Polymer modified waterproof coating Fosroc Nitocote CM 210 seamless, elastomeric water-proof coating.\ni. RCC floor and wall surfaces must be clean, even and sound. Remove all oil, dirt, laitance and other Contaminants by manually and surface shall be fairly smooth finish.\nii. Shamfering the floor wall joints in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement.\niii. Inlet and Outlet pipe - Annular space packing shall be done with Conbextra GP2 mixed with water and providing Supercast SWX as per manufacturerspecification.\niv. Water ponding for minimum 48 hours and injection grouting of construction joints, leaking spots and honey combs with cementitious pressure grouting with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar.\nv.Providing and applying waterproof coat using Nitocote CM210, an elastomeric cementitious coating at 2mm thickness using brush, trowel, squeegee in two coats at coverate of 3.8 Kgs / Sqm. Waterproofing product shall qualify the properties of withstanding cracked substrate cyclic movement from 0 - 300 - 0 microns at 15°C for 6,000 cycles without failure. It shall have the capability to resist a positive water pressure of 5 bar & a negative water pressure of 3 bar when tested to European standard CEN/TC 67-67072:2003 part A-7.\n 2370 Sqm
296 1.295 \nProtective Coating for STP, Aeration, Filtered, Decant, Collection Tank, etc\nSupplying and installation of two component, solvent free coal tar modified epoxy Nitocote ET 402 for floor, wall and ceiling application\ni. RCC surface shall be made dry, clean, even and checked for soundness. Removal of oil, dirt, laitance and other contaminants by manually and surface shall be fairly smooth finish. ii. Filling of tie rod holes if any using Conbextra GP2 mixed with water in ratio:0.16 \niii. Injection grouting of construction joints and honey combs with cementitious pressure grouting with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. iv. Shamfering the floor wall junctions with cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement.\nv. Inlet Outlet Pipe Annular space packing using Conbextra GP2 mixed water and filling as per manufacturer's specification.\nvi. Imperfections and pin holes on the wall surfaces shall be smoothly renderd using Renderoc FC mixed with water in ratio 3:1\nvii. Floor shall be provided with 35mm average screed to slope in CC 1:2:4 mixed with Conplast WL @ 150ml per 50kg bag of cement by main contractor\nviii. Providing and applying high chemical and abrasion resistant coating Nitocote ET402 @ 400microns thickness in two coats using brush or squegee over epoxy primer layer of Nitoprime25.\n 2370 Sqm
297 1.296 ARCHITECTURAL WORKS
298 1.297 MASONRYWORKS
299 1.298 \nProviding and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar using 30kgs/cum of masonry all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). \n
300 1.299 Basement Floor 18 Cum
301 1.3 Ground Floor 94 Cum
302 1.301 First floor 113 Cum
303 1.302 Terrace floor 35 Cum
304 1.303 \nExtra rate over & above Solid Masonry wall for providing RCC Binder 80 mm thick with M20 Grade reinforced cement concrete using coarse graded aggregate of 12 mm and downsize, reinforced with 4 Nos of 8 mm dia Fe500 grade steel and 6 mm dia Mild steel stirrups at 200 mm c/c and binders placed at intervals not more than 1000 mm, including cost of reinforcements and tying in position using binding wire made out of 18 gauge GI annealed, form work, scaffolding, all labour, hire and fuel charges for all tools and plants employed and all other incidental charges etc. all complete, as directed, in 150mm thick walls.\n
305 1.304 Basement Floor 23 Mtr
306 1.305 Ground Floor 97 Mtr
307 1.306 First floor 128 Mtr
308 1.307 \nProviding and applying 10mm thick ceiling plaster including Staircase waist slab in cement mortar mix ratio CM 1:3 (1 Cement : 3 River sand), to internal surfaces of concrete work; including hacking concrete surfaces then applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate, preparing grooves, pattas, wattas, rounding of corners, etc. all complete as per architectural drawings, specifications and finished smooth with wooden rundha etc. or as specified; at all leads, depth and lifts, doing independent double-legged scaffolding, cleaning of surfaces, curing, etc. complete as per specification and to the approval of the PMC/Employer.\n
309 1.308 Ground Floor 1042 Sqm
310 1.309 First floor 1043 Sqm
311 1.31 \nProviding and applying 15mm thick plaster in cement mortar mix ratio CM 1:4 (1 Cement : 4 River sand), to internal surfaces of concrete and masonry work; including raking out joints, hacking concrete surfaces and applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate \n
312 1.311 \nBasement Floor\n 468 Sqm
313 1.312 Ground Floor 1139 Sqm
314 1.313 First floor 1302 Sqm
315 1.314 Terrace floor 476 Sqm
316 1.315 \nProviding and applying minimum 18mm thick double coat cement sand plaster; first coat to be 12mm thick cement sand mortar of mix ratio CM 1:5 (1 Cement : 5 River sand) including adding 2% by weight of cement approved waterproofing compound of approved manufacturer, second coat to be 6mm thick in cement sand mortar of mix ratio CM 1:3 (1 Cement : 3 River sand), finished sand face or as required to receive specified architectural external finish to correct line, plumb and level to external faces of walls, sofits/ceiling if any, including hacking concrete surfaces then applying chemical adhesive coating and a scratch/dash coat as a positive bond, curing the same, racking out junctions of masonry and concrete, then pointing and grouting using non-shrinking compound, joints grouted by pressing square crushed stone, further providing 150mm wide 20 gauge GI chicken mesh at junctions of concrete and masonry work, doing independent double legged scaffolding etc.\nItem also include necessary scafolding, plastering to window sills, RCC cornices, making wattas, drip-moulds, bands, grooves etc., doing curing, cleaning, etc. all complete to the approval of the PMC/Employer. (To External Surfaces)\n 1602 Sqm
317 1.316 \nFLOORING WORKS:- Providing and laying Granolithic flooring (Cement Flooring) of 80mm thick with cement concrete 1:1.5:3 ( 1 cement : 1.5 M- sand : 3 graded stone aggregate ) using 20mm hard broken stone aggregate laid to level or slope in bays not exceeding 3 sqm per panel including providing metal/glass strips to the full depth of the flooring and finishing the top with rubbed, smooth with power trowel, thread lining, curing, including all leads and lifts in all levels etc; complete all as per standard specifications. (The rate is inclusive of necessary planking for panelling wherever necessary as directed by the PMC / Employer Location:- Electrical room, Furniture storage, Compressor, AHU room, Convention & Conference Halls\n
318 1.317 Basement Floor 499 Sqm
319 1.318 Ground floor 866 Sqm
320 1.319 First floor 957 Sqm
321 1.32 Terrace floor 963 Sqm
322 1.321 \nProviding and laying 25mm thick machine cut, machine polished approved Kota stone flooring in pattern and size as detailed in drawing or as directed by the PMC/Employer. Stone to be bedded in 20mm thick cement mortar 1:6 (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, to required line, level; joints to be cleaned and grouted with matching colour approved quality readymade grout, curing, cleaning, polishing, protecting etc. all complete at all heights and leads to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.35/Sft) Location: Service Staircase Tread, Riser & landings\n 229 Sqm
323 1.322 \nJOINERIES \nFD120 Fire rated doors - Painted Providing and fixing of Hollow metal Insulated fire rated doors as per IS 3614 part-1, for stability, integrity & insulation. Pressed galvanized steel conforming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire or third party certified or equivavelent lab, for maximum rating of 120mins with 30minutes of insulation, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label conforming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent.\nDoor frame shall be single rebate grooved profile of size 125 x 60mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff.\nDoor leaf shall be 46mm thick fully flush double skin door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density insulation material. Intumescent seals 15x2mm to be provided all around the door in addition to the grooved smoke seal. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include Supplying and installation of door, inclusive of Hardware fixing and exclusive of hardware Supplying as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.\nApplication: Staircase Exit 120Mins Fire Rated Door Double leaf of size : 1500 x 2100 with vision panel (200 x 300)with hardware set # \n\n 7 Nos
324 1.323 \nSupplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of mechanical device chain and crank operation, providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters, 80x1.25 mm M.S. laths with 1.25 mm thick top cover as per Drawing No: TMA / CTC / GFC / ARCH / A55-C-R0 ( Size of the shutter - 4.0Mtr x 4.50Mtr )\n 4 Nos
325 1.324 \nProviding, fabricating and fixing M.S. railing work as per drawing out of square bars / class ‘C’ pipes / tees / angles / flats / I sections / channels etc. including providing and fixing GI hold fast as necessary to the of RCC members / brick work, electric welding the joints and grinding smooth the welded joints to give one piece appearance including taking site measurements and preparing shop drawing, getting approval of shop drawing prior to fabrication from the PMC/Employ er, assembly finish with two coats of zinc phosphate primer and two coats of approved make and shade epoxy paint all complete to entire satisfaction of the PMC/Employer. (Location: Rear Staircase)\n 946 Kgs
326 1.325 \nCEILING PAINT:- Providing and applying oil bound distemper of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels. (Rate is inclusive of Scrapping the existing RCC Surface and finishing joints smoothly with putty).\n 1042 Sqm
327 1.326 \nINTERNAL EMULSION:- Providing and applying Acrylic emulsion paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); over 2 coats of suitable 1mm thick putty of approved manufacturer including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels.\n 3383 Sqm
328 1.327 \nEXTERNAL PAINT:- Providing and applying Exterior Emulsion Paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor) of newly plastered wall surface with ready mixed paint of first class quality and approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., required scaffolding, leads and lifts at all levels.\n 1602 Sqm
329 2 \nMULTILEVEL CARPARKING \n
330 2.001 \nSTRUCTURAL WORKS\n
331 2.002 \nFOUNDATION PILING:\n
332 2.003 \n650mm dia Pile Boring:- \nProviding and Installation bored Cast-in-situ reinforced cement concrete Piles of Grade M-30 Ready Mix Concrete having Minimum Cement Content as per IS 456 with necessary admixtures and plasticiser. Piles are end bearing piles of basic length 5.00 Mtr and additionally anchoring in the rock at bottom by 1.5 times dia of the piles in all types of soil with driving 8mm thickness of temporary steel casing with necessary stiffener bands and sharp edge at bottom; casing shall be provided up to non-collapsible strata from the existing ground level (as per Site condition), boring in over-burden and through all type of strata encountered up to the founding level as described in the drawing, socketing in approved strata, using bentonite slurry, including disposal of all bored materials etc.complete as per drawings and specifications. Rate is inclusive of Pile boring in all types of soil, Bentonite flushing, Cage lowering, Supplying and installation of concrete, Pile head chipping, Plant installation, collection of sub soil samples in each pile, etc., ( Length of pile for payment shall be measured from toe of pile to bottom of pile cap, Reinforcement will be paid separately ) In all types of soil such as Brownish Clay, Sandy Silty, Clayey sand, Very Dense Completely Weathered Rock etc., (Kindly refer soil report) \n 4209 Mtr
333 2.004 \n650mm dia Pile Integrity testing:-\nPile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.\n 443 Nos
334 2.005 \nPile Reinforcement works:- \nProviding, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as Pile, walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786. ( Note: Helical Reinforcement should be welded as per IS Standards, Authorized Laps, Spacer Bars and Chairs shall be measured for payment )\n 132441 Kgs
335 2.006 \nCEMENT CONCRETE WORKS:- \n
336 2.007 \nProviding, machine mixing and laying Plain cement concrete (PCC) 1:4:8 ( 1 Cement : 4 sand : 8 graded stone aggregate 20mm nominal size ) of required thickness for foundation, rafts, plinth beams, levelling course and all locations, etc. (minimum cementitious content shall be as specified in the IS Code and as approved); including compacting, curing, required shuttering and its removal, dewatering where required and vibrating, cleaning, preparing surfaces, junctions, etc.; complete at all depths and leads as per the drawing and to entire satisfaction of the PMC/Employer. (Note: Using M - sand)\n
337 2.008 \nPilecap & Tie beam\n 138 Cum
338 2.009 \nBelow Grade slab \n 518 Cum
339 2.01 \nREINFORCED CONCRETE WORKS:- \n
340 2.011 \nProviding, transporting, pumping and laying batched design mixed, controlled concrete of different grade (as specified in the Structural drawings) conforming to (IS 456) with minimum cement content and maximum water cement ratio as per IS or as specified by Structural Consultant including using approved quality admixtures and placed either with pump / manual / lift for following grades of concrete including compacting, vibrating, curing and protecting etc., complete at all lead, lift & heights as per the drawing and to entire satisfaction of the PMC / Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. ( No separate payment will be made by the Employer towards wastage ). ( Note: Using M - sand )\n
341 2.012 M30 Grade Concrete - ( Sl. No 2.013 to 2.015 )
342 2.013 Pilecap 1318 Cum
343 2.014 Tie beam 382 Cum
344 2.015 Grade slab 647 Cum
345 2.016 M35 Grade Concrete - ( Sl. No 2.017 to 2.043 )
346 2.017 Shear wall
347 2.018 Ground floor 193 Cum
348 2.019 First floor 150 Cum
349 2.02 Second floor 150 Cum
350 2.021 Third floor 150 Cum
351 2.022 Fourth floor 150 Cum
352 2.023 Fifth floor 150 Cum
353 2.024 Sixth floor 150 Cum
354 2.025 Terrace floor 136 Cum
355 2.026 Columns
356 2.027 Ground floor 197 Cum
357 2.028 First floor 159 Cum
358 2.029 Second floor 159 Cum
359 2.03 Third floor 159 Cum
360 2.031 Fourth floor 159 Cum
361 2.032 Fifth floor 159 Cum
362 2.033 Sixth floor 159 Cum
363 2.034 Terrace floor 80 Cum
364 2.035 Floor Slabs, Beams & Staircase
365 2.036 Ground floor 1296 Cum
366 2.037 First floor 1296 Cum
367 2.038 Second floor 1296 Cum
368 2.039 Third floor 1197 Cum
369 2.04 Fourth floor 1197 Cum
370 2.041 Fifth floor 1197 Cum
371 2.042 Sixth floor 1197 Cum
372 2.043 Terrace floor 165 Cum
373 2.044 FORMWORK:-
374 2.045 \nProviding, fabricating, erecting form work and deshuttering at all levels and places wherever needed/specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles.\n
375 2.046 Pile cap 1862 Sqm
376 2.047 Pilecap tie beam 1827 Sqm
377 2.048 Shear wall 9483 Sqm
378 2.049 Columns 6227 Sqm
379 2.05 Typical Floor Slab 35613 Sqm
380 2.051 Typical Floor Beam 5737 Sqm
381 2.052 Staircase 986 Sqm
382 2.053 REINFORCEMENT WORKS:-
383 2.054 \nProviding, transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as walls, columns / stub columns, beams, slabs, staircase etc.; with correct size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding, etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. TMT bars - Fe-500 grade conforming to IS 1786 ( Note:- Authorized Laps, Spacer Bars and Chairs shall be measured for payment )\n 1.93801e+06 Kgs
384 2.055 POST TENSIONING WORKS:-
385 2.056 \nDesign and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, Supplyinging, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including Supplying of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the PMC / Employer. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Engineer-in-charge \nSupplying & execution of post tensioning work shall be carried out by approved specialized agency, with their own design, equipment, accessories & skilled manpower for satisfactory completion of work as per approved drawings. The contractor shall have minimum 5 years experienced technical staff for proper monitoring, ensuring & certifying the correctness of entire prestressing operations. Prestressing work shall be duly tabulated and report shall be submitted. Item also to include the required scaffolding etc. including marking the PT strand path locations for easy identification etc. all complete to the entire satisfaction of PMC / Employer. Refer Structural Drawing Nos. 1920002-CTC-MLCP-17 / 18 / 19 / 20 & 21\n 142 MT
386 2.057 \nTerrace Waterproofing\nSupplying and installation of single component, Pitch modified polyurethane based Fosroc Nitoproof 600 Std - seamless, elastomeric water-proof coating\na) Surface Preparation- The cleaning and preparation of the substrate to which the Fosroc Nitoproof 600 Std is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application. Surface shall be maintained in dry condition before applying waterproof coating.\nb) Coving at Right Angle Junctions- All the right angle junctions between floor and wall shall be provided with coving of size 75mm x 75mm minimum 15mm thickness in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with Nitobond SBR.\nc) Down Take Pipe Packing- The pipes to be fixed should be filed in order to provided a proper bond and the same to be alligned by the respective agency. The annular space around the Rain water pipe shall be packed using Conbextra GP2, a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR on the core surface fixing leak free form work as per manufacturer's specification.\n
387 2.058 \nd) Pressure Grouting at Leaking points-Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. FIxing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification \ne) Waterproof coating-Providing and applying Fosroc Nitoproof 600 Std a single component pitch modified polyurethane based coating that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane. It is elastomeric, seamless waterproof membrane applied in 2 coats to DFT not less than 1.3 mm thick having a elongation capacity of over 600% . Termination to be done on wall extending the coating to min.300mm height above the finished floor level and sealed inside the groove of 20mm wide x 10mm thick flushed with polymer modified mortar as per vendor recommendation. Laying 200gsm non woven geo textile membrane over Nitoproof 600 Std coating with overlap sealed using synthetic rubber adhesive before providing screed concrete. The material shall comply to – ASTM C 836. Typical cured membrane properties (at 28 days), Elongation (ASTM D412) : 620 %,Specific gravity : 1.5 to 1.55 g/cc, Modulus @ 100% elongation (ASTM D412) : 0.62 N/mm²,Tear resistance (ASTM D624) : 15 N, Water vapour transmission(ASTM E96) : 9.7 g/m2/24 hrs., Permeability (ASTM E96) : 0.063 ng/m/sec/Pa*, Shore A hardness (ASTM D2240) : 50,Artificial weathering : No loss of flexibility after 4000 hours exposure, Extensibility after heat aging (min. requirement -extended to 6.4mm,without cracking) : No cracking or tearing, Service temperature (continuous ambient) : -40°C to 70°C.\n 5219 Sqm
388 2.059 \nScreed Concrete to Slope\nFixing 3mm dia, 75mm square weld mesh over the geo textile surface followed by providing and laying screed concrete of M20 grade of average 75mm thickness with a minimum thickness of 50mm at drain points and a slope of 1:150 or required as per the site condition at all levels by admixing necessary admixtures Conplast WL @ 150ml per bag of cement and mixing Graded fibrillated 100% virgin poly propylene fibres in concrete at the rate of 0.90 kg/cum as per manufacturers specifications. Treatment to continue along the vertical surface for 300mm height in shape of round wata, curing etc. The concrete shall be provided with groove cutting of 6mm x 10mm at every 5m x 5m area, the joints shall be treated with elastomeric sealants Nitoseal PU 40. \n 385 Cum
389 2.06 \nToilet Waterproofing\nSupplying and installation of two component, Polymer modified waterproof coating Fosroc Brushbond RFX seamless, elastomeric water-proof coating.\na) Surface Preparation-The cleaning and preparation of the substrate to which Fosroc Brushbond RFX is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application. Surface shall be maintained in SSD condition before applying waterproof coating.\nb) Coving at Right Angle Junctions-All the right angle junctions between floor and wall shall be provided with coving of size 75mm x 75mm minimum 15mm thickness in cement mortar 1:4 admixed with Nitobond SBR @ 1 litre per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with Nitobond SBR.\nc) Down Take Pipe Packing-The pipes to be fixed should be filed in order to provided a proper bond and the same to be alligned by the respective agency. The annular space around the drain pipe shall be packed using Conbextra GP2, a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR on the core surface fixing leak free form work as per manufacturer's specification.\n
390 2.061 \nd) Pressure Grouting at Leaking points-Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. Fixing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification\ne) Waterproof coating-Providing and applying waterproof coating using Brushbond RFX at 1mm thick in 2 coats at a coverage rate of 12 - 14 sqm per 20.88kg bag with interval period of 6 hours over a substrate with Saturated Surface Dry condition. Termination to be done on wall extending the coating to min.300mm height above the finished floor level and sealed in the termination groove of 20mm wide and 10mm deep flushed with polymer modified mortar as per vendor recommendation. The applied material of Brushbond RFX should have a weight loss of less than 1gm when tested for abrasion resistance according to ASTM-D4060,Tensile strength as per ASTM D638 is 2N/mm² Adhesion to concrete is greater than 1N/mm² and static crack accommodation of 1mm according to ASTM-C836. \n 190 Sqm
391 2.062 \nProtective Plastering\nFine sand shall be sprinkled while the coating is in tacky condition. Providing and laying plastering of 12mm thickness in CM 1:4 mixed with integral waterproofing compound Conplast WL @ 150ml per bag of cement. System include necessary preparation, curing with water, chemicals used, labour, etc as per specification complete\n 190 Sqm
392 2.063 ARCHITECTURAL WORKS
393 2.064 \nMASONRY WORKS\n\n
394 2.065 \nProviding and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar using 30kgs/cum of masonry all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).\n
395 2.066 Ground floor 65 Cum
396 2.067 First floor 66 Cum
397 2.068 Second floor 66 Cum
398 2.069 Third floor 66 Cum
399 2.07 Fourth floor 65 Cum
400 2.071 Fifth floor 65 Cum
401 2.072 Sixth floor 65 Cum
402 2.073 Terrace floor 83 Cum
403 2.074 \nProviding and applying 15mm thick plaster in cement mortar mix ratio CM 1:4 (1 cement : 4 River sand), to internal surfaces of concrete and masonry work; including raking out joints, hacking concrete surfaces and applying approved chemical bonding agent and applying a scratch coat over concrete surfaces by bonding / adhesive chemical coat as directed by approved manufacturer to create a key, cleaning / grooving deep junctions of concrete & masonry, grouting then back by mortar mixed with non-shrinking compound along with packing of clean, fresh square cut aggregate; In All levels\n 8680 Sqm
404 2.075 \nProviding and applying minimum 18mm thick double coat cement sand plaster; first coat to be 12mm thick cement sand mortar of mix ratio CM 1:5 (1 cement : 5 River sand) including adding 2% by weight of cement approved waterproofing compound of approved manufacturer, second coat to be 6mm thick in cement sand mortar of mix ratio CM 1:3 (1 cement : 3 River sand), finished sand face or as required to receive specified architectural external finish to correct line, plumb and level to external faces of walls, sofits/ceiling if any, including hacking concrete surfaces then applying chemical adhesive coating and a scratch/dash coat as a positive bond, curing the same, racking out junctions of masonry and concrete, then pointing and grouting using non-shrinking compound, joints grouted by pressing square crushed stone, further providing 150mm wide 20 gauge GI chicken mesh at junctions of concrete and masonry work, doing independent double legged scaffolding etc.\nItem also include necessary scafolding, plastering to window sills, RCC cornices, making wattas, drip-moulds, bands, grooves etc., doing curing, cleaning, etc. all complete to the approval of the PMC/Employer. (To External Surfaces)\n 3514 Sqm
405 2.076 \nFLOORING WORKS:- Providing and laying approved first quality, colour, design and shade Vitrified Tiles 600mm x 600 mm x 10mm of approved make (conforming to IS 15622, water absorption less than 0.05%) flooring in pattern as detailed in drawing or as directed by the PMC/Employer. Tile to be bedded over minimum 20mm thick cement sand mortar mix ratio 1:6 (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 Kg/Sqm over cleaned surface and spreading neat cement paste using minimum cement about 4.5 Kg/Sqm over cement mortar bed, joints to be cleaned and grouted with matching colour approved quality ploymer based readymade grout, curing, cleaning, to required line, level, protecting till handing over including wastages all complete at all leads, lifts and heights to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.60/Sft ) Location:- Toilets\n 431 Sqm
406 2.077 \nProviding and laying Granolithic flooring (Cement Flooring) of 80mm thick with cement concrete 1:1.5:3 ( 1 cement : 1.5 M- sand : 3 graded stone aggregate ) using 20mm hard broken stone aggregate laid to level or slope in bays not exceeding 3 sqm per panel including providing metal/glass strips to the full depth of the flooring and finishing the top with rubbed, smooth with power trowel, thread lining, curing, including all leads and lifts in all levels etc; complete all as per standard specifications. (The rate is inclusive of necessary planking for panelling wherever necessary as directed by the PMC / Employer. (The rate is inclusive of necessary planking for panelling wherever necessary as directed by the PMC / Employer Location:- Carpark\n
407 2.078 Ground floor 5220 Sqm
408 2.079 First floor 5312 Sqm
409 2.08 Second floor 5555 Sqm
410 2.081 Third floor 5162 Sqm
411 2.082 Fourth floor 5162 Sqm
412 2.083 Fifth floor 5162 Sqm
413 2.084 Sixth floor 5162 Sqm
414 2.085 Terrace floor 4685 Sqm
415 2.086 \nProviding and laying 25mm thick machine cut, machine polished approved Kota stone flooring in pattern and size as detailed in drawing or as directed by the PMC/Employer. Stone to be bedded in 20mm thick cement mortar (1 cement : 6 M-sand) including cleaning and preparing the surface for bedding, spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement about 4.5 kg/sqm over bedding, to required line, level; joints to be cleaned and grouted with matching colour approved quality readymade grout, curing, cleaning, polishing, protecting etc. all complete at all heights and leads to the entire satisfaction of the PMC/Employer. ( Basic Price Rs.35/Sft) Location: Service Staircase Tread, Riser & landings)\n 1990 Sqm
416 2.087 \nCLADDING WORKS:- Providing and fixing approved first quality, colour, design and shade Vitrified Tiles 600 x 600mm x 10mm of approved make (conforming to IS 15622 and EN 176 and water absorption less than 0.05%) dado to walls/columns, as shown in drawing or as directed by the PMC/Employer. Tile fixed over pre-plastered (12mm thick) masonry / RCC surfaces by using approved compatible adhesive (Bal / Laticrete or equivalent approved) over plastered surface to correct line, level and plumb. Joints are well cleaned and grouted with matching colour polymer based approved quality readymade grout and cured, cleaned, junctions with plaster finished smooth, etc. all complete at all heights and leads to the satisfaction of the PMC/Employer. ( Basic Price Rs.60/Sft ) Location:- Toilets\n 910 Sqm
417 2.088 JOINERIES
418 2.089 \nABS DOOR / Equivalent\nProviding and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw. The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated. ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm. PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of ball bearing butterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work Design Pre-laminated door\n 26 Sqm
419 2.09 \nFD120 Fire rated doors - Painted Providing and fixing of Hollow metal Insulated fire rated doors as per IS 3614 part-1, for stability, integrity & insulation. Pressed galvanized steel conforming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire or third party certified or equivavelent lab, for maximum rating of 120mins with 30minutes of insulation, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label conforming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent.\nDoor frame shall be single rebate grooved profile of size 125 x 60mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff.\nDoor leaf shall be 46mm thick fully flush double skin door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density insulation material. Intumescent seals 15x2mm to be provided all around the door in addition to the grooved smoke seal. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include Supplying and installation of door, inclusive of Hardware fixing and exclusive of hardware Supplying as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.\nApplication: Staircase Exit / Electrical rooms 120Mins Fire Rated Door Double leaf of size : 1500 x 2100 with vision panel (200 x 300)with hardware set # \n 36 Nos
420 2.091 \nUPVC Window: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work\n 84 Sqm
421 2.092 \nUPVC Ventilator: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work\n 8 Sqm
422 2.093 \nProviding, fabricating and fixing M.S. railing work as per drawing out of square bars / class ‘C’ pipes / tees / angles / flats / I sections / channels etc. including providing and fixing GI hold fast as necessary to the of RCC members / brick work, electric welding the joints and grinding smooth the welded joints to give one piece appearance including taking site measurements and preparing shop drawing, getting approval of shop drawing prior to fabrication from the PMC/Employ er, assembly finish with two coats of zinc phosphate primer and two coats of approved make and shade epoxy paint all complete to entire satisfaction of the PMC/Employer. (Location: Staircase)\n 4920 Kgs
423 2.094 \nCEILING PAINT:- Providing and applying oil bound distemper of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels. (Rate is inclusive of Scrapping the existing RCC Surface and finishing joints smoothly with putty).\n 48611 Sqm
424 2.095 \nINTERNAL PAINT:- Providing and applying Acrylic emulsion paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor); over 2 coats of suitable 1mm thick putty of approved manufacturer including preparing surfaces, filling up with white cement based putty, binder; cleaning and making the surface dust-free, applying a sealer or primer coat of paint as recommended by approved paint manufacturer, applying two coats of paint (of approved make and shade), required scaffolding, cleaning and protecting till the handing over of site to the employer all complete to entire satisfaction of the PMC/Employer with required scaffolding, leads and lifts at all levels.\n 8690 Sqm
425 2.096 \nEXTERNAL PAINT:- Providing and applying Exterior Emulsion Paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the PMC/Employer must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor) of newly plastered wall surface with ready mixed paint of first class quality and approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., required scaffolding, leads and lifts at all levels.\n 3514 Sqm
426 2.097 \nEXTERNAL FAÇADE:- Supplying & Installation of Aluminum Composite Panels for external wall cladding . The system shall be fixed using annodised aluminum box section for mullions, transform, galvanized steel bolts and nuts complete., all other necessary accessories. The bracket support shall be designed as per manufacturers specification. Fixing shall be done using powder coated rivets.\nNote: Cost includes, Aluminium profiles, Aluminium L-angles, GI brackets, self tapped screws, GI bolts & nuts, rivets, CNC Cutting, spacer tapes, sealants, labour, transport and Scafolding Charges.\nModel: Wood Series ACP from Aludecor ( 4mm thick with 0.5mm skin )\nAluminium Channel for framework 38mm x 25mm x 3mm L angles 50mm x 50mm x 2mm square tubes of Jindal or Equivalent\nHot Dip Galvanised Brackets 50mm x 50mm x 3mm Galvanised metal screws, Non rusting self tapping screws Spacer tapes - 3mm x 10mm (NORTON TAPES) DOWSEAL Weather Sealant 789\n 389 Sqm
427 3 PLUMBING AND SANITARY WORKS
428 3.001 \nSANITARY FIXURES:-\nProviding and fixing in position White colour vitreous china European type Water Closet ( Wall Hung ) of approved make with 110 mm "P" or "S" trap connected with PVC pipe of 110mm dia with Polypropylene soft closed seat cover with CP brass hinges including cost of white cement for packing, spun yarn, teak wood plugs, brass screws, etc., Rate is inclusive of providing and fixing Single Piece Slim Concealed Cistern of 9 litre capacity tank, 40mm dia flush bend connected to tank and closet, necessary accessories, together with cutting and making good the walls, floors wherever required as directed by the Engineer-in-charge. ( Note: Model of EWC and flushing tank with all accessories should be got approved by the Employer ) \na) EWC - Wall-hung closet with seat cover of size ( L=361mm; H=365mm; W=535mm )\nb) Droplet faceplate polished \nc) Connector accessory pack \nd) M12 Rack bolts for wh installation\ne) Insta flush mech tank 3/6L w/o frame \nf) Angle Stop Valve\n 152 Nos
429 3.002 \nProviding and fixing in position White colour vitreous china European Floor mounted Water Closet for Physically Challenged of approved make with 220 mm "P" or "S" trap connected with PVC pipe of 110mm dia with Polypropylene soft closed seat cover with CP brass hinges including cost of white cement for packing, spun yarn, teak wood plugs, brass screws, etc., Rate is inclusive of providing and fixing of Plastic Cistern of 9 litre capactiy tank, 40mm dia flush bend connected to tank and closet, Elbow operated knob, Foldable hinged arm, grab bar, down rails, C.P bolts, nuts, necessary accessories, together with cutting and making good the walls, floors wherever required as directed by the Engineer-in-charge. ( Note: Model of EWC and flushing tank with all accessories should be got approved by the Employer ) \na) EWC - Floor mounted closet 2 piece with seat cover of size ( L=365mm; H=765mm; W=673mm )\nb) Connector, rubber \nc) Cruz bath entry grip \nd) Angle Stop Valve\n 7 Nos
430 3.003 \nProviding and fixing white colour vitreous china flat back half stall urinal with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps ( all in C.P. brass ) with waste fitting as per IS: 2556, PVC trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required ( Note: Model of Urinal & Sensor Kit with all accessories should be got approved by the Employer )\na) Urinal with rear inlet of size ( L=284mm; H=575mm; W=378mm; D=284mm )\nb) Standard Bottle Trap 300mm\nc) Urinal Sensor\n 294 Nos
431 3.004 Providing and fixing of Ceramic White Urinal partition of approved make with necessary supports, bolts, nuts, etc., \nSize ( W=365mm; H=750mm; T=165mm ) 273 Nos
432 3.005 \nProviding and fixing of white colour Under Counter wash Basin of approved make with basin piller cock, Bottle Trap, fully Casted Body, 32 mm dia pvc drain pipe of height 190 mm and 125 mm long Connecting Pipes & Wall Flange, Waste Coupling 32mm Size Half Thread with 130mm height and rubber adaptor for waste connection. Supplying of 1 no approved make CP angle cock together with 15mm brass nipple, 15mm dia nylone connection, including fixing of wash basin using CI brackets on the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water Supplying connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the Engineer-in-charge. ( Note: Model of wash basin with all accessories should be got approved by the Employer )\na) Ovel Shaped Under Counter Basin ( L=536mm; W=435mm )\nb) Piller Tap \nc) Angle Stop Valve\nd) Grid Drain With Over Flow Hole\ne) Standard Bottle Trap 300mm\n 120 Nos
433 3.006 \nProviding & Fixing of Stainless steel Double bowl sink of approved make (48"x20"x8") with drain points for connect the waste couplers, with necessary supports, CI brackets, bolts, nuts at equal intervals, etc., Fixing of Double bowl sink, wall hook and angle valve, including wall chasing, making good the same, complete with standard specification and as directed by the Engineer-in-charge. ( Note: Model of Sink with all accessories should be got approved by the Employer )\na) Sink Folded edge gloss finish\nb) sink cock \nc) Angle Stop Valve\nd) Standard Bottle Trap 300mm\n 4 Nos
434 3.007 Providing and fixing CP brass Paper holder roller in polished chrome of approved make complete with CP brackets fixed to wooden cleats with CP brass screws. 159 Nos
435 3.008 Providing and fixing CP brass towel rail size of 600x20 mm of approved make complete with CP brackets fixed to wooden cleats with CP brass screws and washers complete. 45 Nos
436 3.009 Supply & Fixing of approved make, no touch operting, fully hygienic hand drier of approved shade with single/double blower, with time delay, including providing necessary brackets, cable from drier to Plug, Plug top key and lock etc, complete as directed by the Engineer-incharge. 31 Nos
437 3.01 Providing and fixing of approved make C.P. brass bib cock of approved quality conforming to IS:8931,18.49 15mm nominal bore 32 Nos
438 3.011 Providing and fixing of approved make C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms,18.50 15 mm nominal bore 4 Nos
439 3.012 Providing and fixing of superior quality of approved type and design of pedal operated Waste Bin in all Toilets. 43 Nos
440 3.013 Providing and fixing of c.p. brass twin headed Double coat hook with all necessary screw fitting to complete 159 Nos
441 3.014 Supply & fixing of approved make, matt finish Cockroach trap 125 x 125 mm SS floor grating with Hinge 295 Nos
442 3.015 Providing and fixing of approved make, SS floor clean out 96 Nos
443 3.016 Supply & Fixing of soap dispenser, push-button type, white/smoked with necessary fittings, etc., complete. 45 Nos
444 3.017 Providing and fixing Health faucet along with wall fixing bracket, 1 m long flexible tube, making good the same, complete. 159 Nos
445 3.018 WATER Supplying PIPES AND FITTNGS (INTERNAL AND EXTERNAL:
446 3.019 \nINTERNAL EXPOSED TO WALL:- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to ASTM D-2846, SDR11 upto 50mm dia & Sch 40 for above 50mm dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings that is Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings connection between CPVC & metal pipe/GI) ie. Brass Adaptors (both Male & Female threaded), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement conforming to ASTM F493 and testing of joints complete as per direction of Engineer in Charge. Rate Quoted shall be inclusive of cost of other consumables like hacksaw blade, solvent for CPVC pipe, etc. The work shall include Providing and fixing of necessary angles/channels for supports, chasing of walls, grouting of supports, painting of supports etc., complete.\n
447 3.02 25 mm dia 800 Rmt
448 3.021 32 mm dia 112 Rmt
449 3.022 40 mm dia 1237 Rmt
450 3.023 50 mm dia 83 Rmt
451 3.024 65 mm dia 95 Rmt
452 3.025 \nINTERNAL - CONCEALED WORK:- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to ASTM D-2846, SDR11 upto 50mm dia & Sch 40 for above 50mm dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings that is Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings connection between CPVC & metal pipe/GI) ie. Brass Adaptors (both Male & Female threaded), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement conforming to ASTM F493 and the cost of cutting chases, making good the same including testing of joints complete as per direction of Engineer in Charge. Rate Quoted shall be inclusive of cost of other consumables like hacksaw blade, solvent for CPVC pipe, etc.\n
453 3.026 20 mm dia 5307 Rmt
454 3.027 Providing and fixing male/ female screwed end full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated ball & teflon seat tested to a pressure 15 Kg / sqcm with (threaded joints) complete as required and as complete, as directed by Engineer-Incharge
455 3.028 20 mm dia 63 Nos
456 3.029 25 mm dia 354 Nos
457 3.03 32 mm dia 23 Nos
458 3.031 40 mm dia 11 Nos
459 3.032 50 mm dia 14 Nos
460 3.033 Providing and fixing of approved make C.I. body, EPDM seat, SS disc, Butterfly valve PN 16, SGI Hand lever operated, wafer ends conforming to BS:5155. The scope of work includes requried flanges to connect the pipes, etc.,as directed by Engineer-Incharge.
461 3.034 65 mm dia 48 Nos
462 3.035 80 mm dia 40 Nos
463 3.036 100 mm dia 23 Nos
464 3.037 150 mm dia 2 Nos
465 3.038 \nProviding and fixing of approved make of GM Non return valve, suitable for both horizontal & vertical application conforming to BS 1982 tested to a pressure of 15 Kg/sqcm. Including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required, shutter of brass/SS304 conforming to ASTM B159. as directed by Engineer-Incharge.\n
466 3.039 50 mm dia 2 Nos
467 3.04 65 mm dia 20 Nos
468 3.041 80 mm dia 15 Nos
469 3.042 100 mm dia 13 Nos
470 3.043 \nProviding and fixing Diapghram type, approved make pressure reducing station for cold water supply comprising of 3 nos CI butterfly valves on inlet, outlet, and bye-pass, conforming to BS5155, 1 Nos Gun metal pressure reducing valve with flanged connection, The complete system is tested to a pressure of 10 Kg/Sq.cm and suitable to reduce the pressure up to 2 Kg/Sq.cm) Including flanges, unions, nuts, bolts and washers complete as as directed by Engineer-Incharge.\n
471 3.044 40 mm dia 2 Nos
472 3.045 50 mm dia 2 Nos
473 3.046 65 mm dia 2 Nos
474 3.047 80 mm dia 2 Nos
475 3.048 Providing and fixing of of approved make automatic air release valve with 1/2 ball valve as directed by Engineer-Incharge. 28 Nos
476 3.049 Providing and fixing of approved make 50mm dia, Brass float valve, complete brass body contruction, PN6 rating, with SS ball. The scope of work includes terminating the OHT inlet pipe and positioning for smooth operation. 5 Nos
477 3.05 \nProviding and fixing GI. puddle flanges (IS 1239) fabricated out of 6 mm thick M.S. plate of size 300 x 300mm plus dia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.\n
478 3.051 40 mm dia 10 Nos
479 3.052 50 mm dia 10 Nos
480 3.053 65 mm dia 10 Nos
481 3.054 80 mm dia 10 Nos
482 3.055 100 mm dia 10 Nos
483 3.056 150 mm dia 10 Nos
484 3.057 EXTERNAL WATER Supplying & INTERNAL DRAINAGE
485 3.058 \nSOIL, WASTE & VENT: Providing and fixing of UPVC as per IS-13592, Type B with solvent 'weld type joints together UPVC pipes with necessary reducers if required, together uPVC pipe specials, vent cowls, of approved make, The pipes shall be duly fixed at site, with necessary cutting & jointing of pipe with approved quality jointing lubricant. The pipe shall be fixed properly aligned vertical with suitable MS pipe clamps. Work to include making necessary holes in the masonary walls etc.. and making good the damaged portions with mortar filling with 1:4 mix. Before handing over, leak test shall be carried out and any defects found shall be rectified. The work shall include Providing and fixing of necessary angles/ channels for supports, chasing of walls, grouting of supports, painting of supports etc., complete. Rate Quoted shall be inclusive of cost of cement, sand and other consumables like hacksaw blade etc.\n
486 3.059 75 mm O.D pipe Type - B 644 Rmt
487 3.06 110 mm O.D pipe Type - B 1117 Rmt
488 3.061 \nSupply of rigid PVC pipes as per IS 4985, 6Kg/Cm2 complete with necessary solvent cement joint fittings IS 7834 for drain piping between the bottle traps and up to the floor traps. Erection of the above pipe including cutting, jointing of the pipes with necessary fittings, encasings, erection of the pipes in wall chasing with necessary clamps and making good the chasings. Rate Quoted shall be inclusive of cost of cement, sand and other consumables like hacksaw blade etc.\n
489 3.062 40 mm dia 220 Rmt
490 3.063 50 mm dia 2076 Rmt
491 3.064 75 mm dia 600 Rmt
492 3.065 110 mm dia 300 Rmt
493 3.066 \nProviding and fixing in position deep seal multiway PVC floor Trap with cockroach trap and PVC extension piece of required length depth of following size to suit site conditions and multiple inlets, to suit site conditions with inlet sizes ranging from 40 mm to 75 mm. The bottom of the sump shall be dummied water tight. Wherever, sumps are shown to have water seal, the seal depth shall be minimum 40 mm. The sump shall be laid in cement concrete bed with 1:3:6 mix with 20 mm brick jelly bed all around. Providing and fixing heavy class C.P. brass mosquito proof grating with frame of approved design including setting in floor with cement mortar to match with floor finish. The scope of work includes making necessary sleeve arrangement in the slab.\n 295 Nos
494 3.067 \nProviding, fixing, jointing and testing in position the spun cast iron pipe conforming to I.S. : 3989 cut to required lengths including all necessary fittings and specials such as Bends, Tees, junctions, offsets, access pieces (plain or door) & vent cowl. Fixing at wall/ceiling level supported by clamps & hangers etc. Making proper connection with refined pig lead joint of required depth including cutting, chases/holes in floors /walls/ slab etc and making good the same after pipe have been duly laid and testing complete. The scope work includes neccessary heavy clamps, Angles, supports etc., 17.35.1.2 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989\n
495 3.068 100mm C.I Spun Pipe 256 Rmt
496 3.069 150 mm C.I Spun Pipe 124 Rmt
497 3.07 \nProviding, fixing, jointing and testing of CI floor traps, making opening and neat core paking & water proofing around the floor trap without water leakage, necessary supports for holding the floor traps, with outlet 100mm\n 36 Nos
498 3.071 \nProviding and fixing of approved make SS304 frame & removable 300x300x300 square frame & grating, making sleeve arrangement in the slab, core packings, water leak arrests, etc., chasing in the floor, fixing the grating support in the concrete, and making connection to the CI floor trap for kitchen area.\n 36 Nos
499 3.072 \nRAINWATER PIPES & FITTINGS:- Providing and fixing of rigid PVC pipes as per IS 4985, 6Kg/Cm2, Class III, complete with necessary solvent cement joint fittings IS 7834 for drain piping between the bottle traps and up to the floor traps. Erection of the above pipe including cutting, jointing of the pipes with necessary fittings, encasings, erection of the pipes in wall chasing with necessary clamps and making good the chasings.\n
500 3.073 200 mm OD pipes 2762 Rmt
501 3.074 \nProviding and fixing of Approved 'make or Equivalent make roof drains, CI body with aluminium ring, with SS flat grate and screws including making necessary sleeve arrangement in the slab, core packings, water leak arrests, etc., chasing in the floor, fixing the grating support in the concrete, fixing the grating in the support and making connection to the rain water down coming pipe without any leak, painting the grating with one coat of primer and two coats of black enamel paint.\nRoof drains outlet 200mm Dia\n 87 Nos
502 3.075 \nDesigning and constructing brick masonry inspection chamber of the following sizes in brick work of class 75 in cement mortar 1:5 (1 cement:5 fine sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm. nominal size) embeded with frame for manhole, RCC foundation slab. 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone aggregate 40 mm nominal size) both inside and outside of plastering 12 mm thick with cement motar 1:3 (1 cement : 3 coarse sand) with a floating coat of neat cement on inside face, proper water proofing to ensure no ground water seepage in the manhole, Poly propylene (conforming to ASTMD - 4101) foot rests (meeting the 224 kg load requirement as per IS 5455) at 300 mm spacing, benching and making channels with 1:2:4 cement concrete neatly finished, including necessary centering and shuttering, reinforcement, excavation, in all kind of soil, dewatering, refilling, watering, ramming and removing the surplus excavated earth, making good the same complete as required with 600x600 approved make Heavy duty cover and frame not less than 208kg, (Weight of cover 108kg and weight of frame 100kg). 120Cm x 75Cm size upto 90Cm\n 30 Nos
503 3.076 \nConstruction of percolation well / rain water harvest pit of of required internal dimension of 1.2mtr Dia upto 2.5 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement, With perforated RCC cover, fixed over 100 mm P.C.C, Rungs, etc. The work shall include necessary exacavation and backfilling placing 2 nos of 200mm dia slotted pie for 5mtr from the bottom of the catch pit, 25mm coarse aggregate (black pebbles) for filteration.\n 64 Nos
504 3.077 EXTERNAL DRAINAGE
505 3.078 \nSEWERAGE LINE:- Providing, fixing, jointing and testing in position the following UPVC pipes confirming to IS:4985 of 10 Kg / Sq.cm for drainage system cut to required length. The pipes shall be duly laid at site, with necessary cutting & jointing of pipe with approved quality jointing lubricant. The pipes shall be fixed properly aligned and laid to slope. Before handing over, leak test shall be carried out and any defects found shall be rectified. Work shall also include necessary excavation and back filling 'with compaction etc, as directed by Engineer- Incharge (For sewer and Sullage line)\n
506 3.079 75mm dia 13 Rmt
507 3.08 110mm dia 83 Rmt
508 3.081 160mm dia 64 Rmt
509 3.082 200mm dia 94 Rmt
510 3.083 250 mm dia 103 Rmt
511 3.084 \nSupply of Glazed stoneware gully trap of size 150 x 100 mm with 100 mm outlet, CI grating to suit the size of the gully mouth, CI cover & frame of 300 x 300 mm clear opening of 7 kg weight, complete. Laying in position the above glazed stone ware gully trap including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm inside clear in brick masonry, 15 mm thick plaster with cement mortar (1:3) on both internal and external surfaces, inside finished with floating coat of neat cement. Fixing C.I frame and cover 300 x 300 mmX7 kgs wt (clear opening), cover painted with 2 coats of anti-corrosive black bitumastic paint etc., complete. The work shall include necessary excavation and backfilling. ( Air tight heavy duty covers for gully traps which falls in parking area )\n 10 Nos
512 3.085 \nConstruction of sewer chambers of required internal dimension of 600x600mm depth upto 0.8 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement. Neco make Heavy duty DI manhole cover with hinged frame. fixed over 100 mm P.C.C. including painting of the frame, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include top slab of aroungd 150mm concrete structure for the mentioned size & making arrangement for manhole cover seating, necessary exacavation and backfilling.\n 10 Nos.
513 3.086 \nConstruction of sewer chambers of required internal dimension of 600x750mm depth upto 1.0 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement. Neco make Heavy duty DI manhole cover with hinged frame. fixed over 100 mm P.C.C. including painting of the frame, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include necessary exacavation and backfilling.\n 5 Nos.
514 3.087 \nConstruction of sewer chambers of required internal dimension of 600x900mm upto 1.2 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement. With 600X600 Neco make Heavy duty DI manhole cover with hinged frame. fixed over 100 mm P.C.C. including painting of the frame, rugs for accessing, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include top slab of aroungd 150mm concrete structure for the mentioned size & making arrangement for manhole cover seating, necessary exacavation and backfilling.\n 4 Nos.
515 3.088 \nConstruction of sewer chambers of required internal dimension of 1200x1200mm upto 2.0 Mtr depth with brick masonry in cement mortor 1:5 thickness of masonry 225 mm, 1:3:6 cement concrete foundation 150 mm thick over 150 mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface finished with floating coat of neat cement. Neco make 600X600 Medium duty DI manhole cover with hinged frame. fixed over 100 mm P.C.C. including painting of the frame, rugs for accessing, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include top slab of aroungd 150mm concrete structure for the mentioned size & making arrangement for manhole cover seating, necessary exacavation and backfilling.\n 6 Nos.
516 3.089 \nDesigning and constructing brick masonry inspection chamber of the following sizes in brick work of class 75 in cement mortar 1:5 (1 cement:5 fine sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm. nominal size) embeded with frame for manhole, RCC foundation slab. 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone aggregate 40 mm nominal size) both inside and outside of plastering 12 mm thick with cement motar 1:3 (1 cement : 3 coarse sand) with a floating coat of neat cement on inside face, proper water proofing to ensure no ground water seepage in the manhole, Poly propylene (conforming to ASTMD - 4101) foot rests (meeting the 224 kg load requirement as per IS 5455) at 300 mm spacing, benching and making channels with 1:2:4 cement concrete neatly finished, including necessary centering and shuttering, reinforcement, excavation, in all kind of soil, dewatering, refilling, watering, ramming and removing the surplus excavated earth, making good the same complete as required with 600x600 approved make Heavy duty cover and frame not less than 208kg, (Weight of cover 108kg and weight of frame 100kg).\n
517 3.09 120Cm x 75Cm size upto 90Cm 25 Nos
518 3.091 120Cm x 75Cm size upto 90Cm 25 Nos
519 3.092 Extra for depth for manholes for 100Cm 20 Rmt
520 3.093 \nProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to ASTM D-2846, SDR11 upto 50mm dia & Sch 40 for above 50mm dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings that is Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings connection between CPVC & metal pipe/GI) ie. Brass Adaptors (both Male & Female threaded), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement conforming to ASTM F493 and testing of joints complete as per direction of Engineer in Charge. Rate Quoted shall be inclusive of cost of other consumables like hacksaw blade, solvent for CPVC pipe, etc.\n
521 3.094 50 mm dia - SDR 11 269 Rmt
522 3.095 65 mm dia - Sch 40 334 Rmt
523 3.096 80 mm dia - Sch 40 387 Rmt
524 3.097 \nSupply and installation of approved make CI manhole cover size 600x600 with theft proof hinged frame. fixed over 100 mm P.C.C. including painting of the frame, cover with 2 coats of anti- corrosive bitumastic paint over a coat of primer all as per specifications. The work shall include necessary exacavation and backfilling.\n
525 3.098 Medium duty, Grade B-125, 600mm x 600mm 20 Nos
526 3.099 Light duty Grade A-15, 600mm x 600mm 8 Nos
527 3.1 UTILITY PUMPS
528 3.101 \nSupply & Fixing of Water supply Hydro Pneumatic System Pumps, approved make Variable flow 2 Pump system, 2 working + 1 stand by, For pumping the Domestic water from sump to proposed campus. The cost shall include necessary Control Valves, pressure vessel, pressure switch, Non-Return Valves, interconnecting pipes in the system, foot valves, etc., 20m3/Hr@ not less than 46mtr Head, Each Pumps shall deliver 10m3/hr @ head of 46mtr with necessary starter, starter panel and cabling With required Pressure vessel of welmet make, The electrical contractor will leave the cable near the pump room with MCB or MCCB. The PHE contractor shall consider the cabling from the MCB or MCCB to individual pumps and starters. apprx length of cable shall be 20 RMT.\n 1 Set
529 3.102 \nSupply & Fixing of Water supply Hydro Pneumatic System Pumps, of approved make Variable flow 2 Pump system, 2 working + 1 stand by, For pumping the Flush water from sump to proposed campus. The cost shall include necessary Control Valves, pressure vessel, pressure switch, Non-Return Valves, interconnecting pipes in the system, foot valves, etc., 20m3/Hr@ not less than 46mtr Head, Each Pumps shall deliver 10m3/hr @ head of 46mtr with necessary starter, starter panel and cabling With required Pressure vessel of welmet make, The electrical contractor will leave the cable near the pump room with MCB or MCCB. The PHE contractor shall consider the cabling from the MCB or MCCB to individual pumps and starters. apprx length of cable shall be 20 RMT.\n 1 Set
530 3.103 \nSupply & Fixing of Water supply Hydro Pneumatic System Pumps, of approved make Variable flow 1 Pump system, 1 working + 1 stand by, For pumping the RO water from sump to proposed campus. The cost shall include necessary Control Valves, pressure vessel, pressure switch, Non-Return Valves, interconnecting pipes in the system, foot valves, etc., 10m3/Hr@ not less than 40mtr Head, Each Pumps shall deliver 10m3/hr @ head of 46mtr with necessary starter, starter panel and cabling With required Pressure vessel of welmet make, The electrical contractor will leave the cable near the pump room with MCB or MCCB. The PHE contractor shall consider the cabling from the MCB or MCCB to individual pumps and starters. apprx length of cable shall be 20 RMT.\n 1 Set
531 3.104 \nSupply and installation of approved make, sewage submersible transfer cutter version pump with solid handling capacity of 40mm, Head Vertical height of 25Mtr, Flow 15m3/Hr, (1W+1S) with complete connections, float switches, drain points, required coupling valves,non return valves, control panel, required wiring between panel and motors, required pump supports - Sewage & Waste Disposal collection pit.\n 1 Set
532 3.105 \nSupply and installation of approved make, submersible Dewatering non clog pump (1working + 1 stand by), 75m3/Hr vertical height of 15 mtr, with complete connections, float switches, drain points, required couplings, valves, non return valves, stater panel, required cabling between panel and motors, required pump supports and pulling threads, etc., - Rain Water storage Area.\n 2 Set
533 3.106 \nSupply and installation of approved make, submersible water transfer pump, Head Vertical height of 25Mtr, Flow 15m3/Hr, (1W+1S) with complete connections, float switches, drain points, required coupling valves,non return valves, control panel, required wiring between panel and motors, required pump supports - Rain Water Storage.\n 3 Set
534 3.107 \nProviding and fixing Position in MS angles/channels for supports, grouting of supports, for laying pipes at terrace floor, Pump rooms, service corridor, painting of supports etc., complete. The work shall also include painting of the entire supports, with one coat of Zinc Chromate primer & Two coats of approved make enamel paint the color shade shall be recommended by the client to suit the wall background. \n 3940 Kgs
535 3.108 \nDrilling of Borewells anywhere in TamilNadu including transportation from one place to another with in TamilNadu in alluvial soil sedimentary strata of clay and sand stone shale pennles boulders etc. By first taking a pilot bore of 140mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drilling at site.- Up to 60m depth ending below ground level. (2 Nos borewells each 120 RM).\n
536 3.109 Up to 60m depth ending below ground level. 120 Rmt
537 3.11 From 60m upto 90m Depth ending from ground level 60 Rmt
538 3.111 From 90m upto 120 m Depth ending from ground level 60 Rmt
539 3.112 Up to 60m depth ending below ground level. 120 Rmt
540 3.113 From 60m upto 90m Depth ending from ground level 60 Rmt
541 3.114 From 90m upto 120 m Depth ending from ground level 60 Rmt
542 3.115 \nLabour Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor.\n 16 Hour
543 3.116 \nLabour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer.\n 240 Rmt
544 3.117 Supply and fixing of 160mm dia PVC special Blue pipes for Borewells
545 3.118 Plain pipes 120 Rmt
546 3.119 Slotted special blue pipes 120 Rmt
547 3.12 Suply and erection of 3HP Submerssible pumpset suitable for 150mm dia Borewell with ISI mark IS8034 with Panel board DOL with two level Guard and Auto start. The cost including all taxes and the panel board should be provided as per specification given with erection charges. 2 Nos.
548 3.121 Supply and run of 4 sq.mm 3 core flat type copper cable 340 Rmt
549 4 \nPROVIDING ELECTRICAL WORKS \n\nHT Panel Installation & Transformer \n
550 4.001 \nEstablisment of 33kv receiving station \nOut door type- 33kv ring main gear unit\nSupply, Erection, Testing and commissioning of 1 set of totally enclosed, floor standing, sheet steel clad cubicle pattern Outdoor type RMG Panel 33 KV HT Switch Board, consist 2nos of 33KV 1250A VCB as incomer and 1 no of 33KV 1250A VCB as outgoing panel with one set of 1500 amps coloured PVC sleeved copper bus bars and accessories as per detailed specification , Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 and TANGEDCO latest norms.\n 1 Set
551 4.002 \nout door type- 33kv single VCB metering panel \nSupply, Erection, Testing and commissioning of 1 set of totally enclosed, outdoor type floor standing, sheet steel clad cubicle pattern 1 Panel 33 KV (Metering Panel) HT Switch Board, 1 no of 33KV 1250A VCB as Incomer one set of 1500 amps coloured PVC sleeved copper bus bars and accessories as below and as per detailed specification , Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 1 Set
552 4.003 Establisment of 33kv sub station \nIndoor type- 33kv HT 7 panel \nSupply, Erection, Testing and commissioning of 1 set of totally enclosed, indoor type floor standing, sheet steel clad cubicle pattern 7 Panel 33 KV HT Switch Board, 1 no of 33KV 1250A VCB as Incomer and 4Nos of 33KV 630A VCB as outgoing panel and 2Nos of 33KV 1250A VCB as buscoupler panel with Mechanical + Electrical interlock and provide one set of 1500 amps coloured PVC sleeved copper bus bars and accessories including (BATTERY CHARGER –BATTERY – DC PANEL SYSTEMS)\nSupply & fixing of Battery charger should be 110VDC/60Amps output capacity and input should 415VAC with auto/Manual control, Triple/boost charging mode with fully automatic control.\nBattery should be 110V/200AH battery tubular battery.\nDC panel with 10 output and 100Amps MCB with input, Overvoltage /under voltage, Earth leakage protection and dc cable as required,etc..should be provide as per revised technical specification and Refer Revised Single line diagram, Drawing no TM-082-CH-CTC-GFC-EL-SLD-E-01-R0 1 Set
553 4.004 \nOut door type-4 MVA Power TR-1,2&3:\nSupply, Erection, Testing & commissioning of Outdoor type 4 MVA ,3 phase , 50Hz, 33KV/11KV, DYn 11, Impedance 7.5%(Suitable operation of Parallel Concept) , 3 Phase ONAF type copper wound transformer with ON LOAD TAP CHANGER without AVR &with RTTC Panel as per IS 2026, with all standard accessories. The transformer shall be having cable end box capable of receiving 1 No. 3 X 300 sq. mm. XLPE HT 33 KV Cable on HV side and 1 No. 3 X 300 sq. mm. XLPE HT 11 KV Cable on LV side, complete with all accessories as per specification , Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 3 Each
554 4.005 \nINDOOR TYPE- 11KV HT 9 PANEL :- Supply, Erection, Testing and commissioning of 1 set of totally enclosed, Indoor type floor standing, sheet steel clad cubicle pattern 9 Panel 11 KV HT Switch Board consistsing of 3 nos of 11KV 630A VCB as Incomer and 4 Nos of 11KV 630A VCB as outgoing panel and 2no. of 11KV 630A VCB as Bus coupler with Mechanical + Electrical interlock and provide one set of 1500 amps coloured PVC sleeved copper bus bars, Surge arrester , accessories and as per detailed specification and Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 1 Set
555 4.006 \nEstablisment of 11kv sub station \nIndoor type- 11kv HT 8 panel :- Supply, Erection, Testing and commissioning of 1 set of totally enclosed, Indoor type floor standing, sheet steel clad cubicle pattern 8 Panel 11 KV HT Switch Board consistsing of 2 nos of 11KV 630A VCB as Incomer and 5 Nos of 11KV 630A VCB as outgoing panel and 1 no. of 11KV 630A VCB as Bus coupler with Mechanical + Electrical interlock and provide one set of 1500 amps coloured PVC sleeved copper bus bars, Surge arrester , accessories and as per detailed specification and Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 1 Set
556 4.007 \nOut door type-2000 KVA TR:-\nSupply, Erection, Testing & commissioning of Outdoor type 2000KVA ,3 phase , 50Hz, 11 KV/433 V, DYn 11, Impedance 6.25% (Suitable operation of NON Parallel Concept) , 3 Phase ONAN type copper wound transformer with ON LOAD TAP CHANGER with AVR & with RTTC Panel as per IS 1180, Level-II, with all standard accessories. The transformer shall be having cable end box capable of receiving 1 No. 3C X 240 sq. mm. XLPE HT 11 KV Cable on HV side and Flanges on LT side suitable for bus duct arramgement, complete with all accessories as per detailed specification and Single line diagram TMA-82 / CH / CTC / GFC / E-SLD / E-01 / R0 . 4 Each
557 4.008 \nHT Cable & End Termination\nSupply and laying of following sizes of Aluminium conductor cable, 33 KV (E) and 11 KV (E) grade, XLPE, Single steel tape armoured, HV cable 3 core cable direct in ground including excavation, sand cushioning, protective covering, refilling the trench and provide the hume pipe where ever required road crossing etc. and as per specification\n
558 4.009 33 KV 3C 300 sq.mm. XLPE Armoured Cable .from RMG to metering panel & Metering panel to 33KV HT 5 panel. 295 Metre
559 4.01 33 KV 3C 300 sq.mm. XLPE Armoured Cable form 33KV HT 5 panel to Primary side of 4MVA power transformers. 222 Metre
560 4.011 11 KV 3C 300sq.mm. XLPE Armoured Cable. From 4MVA secondary side to 11KV HT 9 panel. 178 Metre
561 4.012 11 KV 3C 300sq.mm. XLPE Armoured Cable. From HT 9 Panel to 11KV HT 8 panel . 926 Metre
562 4.013 11 KV 3C 300sq.mm. XLPE Armoured Cable. From HT 9 Panel to 11KV HT 6 panel at Existing Utility building . 35 Metre
563 4.014 11 KV 3C 240sq.mm. XLPE Armoured Cable. From 11KV HT 8 panel to 11KV/0.433KV Distribution transformer. 156 Metre
564 4.015 \nSupplying and making end cable termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 33KV XLPE aluminuim conductor of 3 core, 300 sqmm cable. \n 12 Each
565 4.016 \nSupplying and making end cable termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 11KV XLPE aluminuim conductor of 3 core, 300 sqmm cable. \n 12 Each
566 4.017 \nSupplying and making end cable termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 11KV XLPE aluminuim conductor of 3 core, 240 sqmm cable. \n 8 Each
567 4.018 \nSupplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for 33KV XLPE aluminuim conductor of 3 core,300 sqmm cable. \n 2 Each
568 4.019 \nSupplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for 11KV XLPE aluminuim conductor of 3 core,240 sqmm cable. \n 4 Each
569 4.02 \nSupply,laying,testing and commissioning of control cable size 24 core 2.5 sqmm PVC insulated, PVC sheathed armoured copper conductor cable. \n 120 Metre
570 4.021 Supply, terminations,testing and commissioning of control cable size 24 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. 8 Each
571 4.022 Supply,laying,testing and commissioning of control cable size 16 core 2.5 sqmm PVC insulated, PVC sheathed armoured copper conductor cable. 30 Metre
572 4.023 Supply, terminations,testing and commissioning of control cable size 16 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. 6 Each
573 4.024 Supply,laying,testing and commissioning of control cable size 12 core 2.5 sqmm PVC insulated, PVC sheathed armoured copper conductor cable. 40 Metre
574 4.025 Supply, terminations,testing and commissioning of control cable size 12 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. 8 Each
575 4.026 Supply,laying, testing and commissioning of control cable size 7 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. 120 Metre
576 4.027 Supply, terminations,testing and commissioning of control cable size 7 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. 8 Each
577 4.028 Supply,laying, testing and commissioning of control cable size 3 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. 60 Metre
578 4.029 Supply, terminations,testing and commissioning of control cable size 3 core 2.5 sqmm PVC insulated, PVC sheathed copper conductor cable. 6 Each
579 4.03 Electrical cables, LT panels ,Wiring & Light fixtures ,Earthing etc.
580 4.031 \nLT panel board\nMain MV panel -3\nSupply, Installation, Testing and Commissioning of Medium Voltage floor mounting Cubicle Type Single bus bar system Panel Board suitable for 415 V, 3 Phase, 50 Hz Power Distribution System with the following mounting complete as per specifications attached.\nA) Incomer - 2Nos. For Transformer 5 & 6 : \n3200 AMPS ACB, 65 KA (Ics) AC Motor operated Draw Out ( EDO ) Type Four Pole Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:- 1No - Class 1.0, Digital Maximum Demand Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fuses etc.\n1No - Multi control relay for contorl of Under voltage, Over voltage, Single phase preventor, Phase rotation, with control fuses wiring etc.\n3Nos. - 3200/5A CL-1, 15VA current transformer with CT short link terminal block for Maximum demand Meter.\n1 No. - CDG11 Earth Fault relay \n4 No. 3200/5A 5P10 15VA Current transformer with CT short link terminal block for Earth fault relay\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\n3 No. 3200/5A CL-1, 15VA Current transformer with CT short link terminal block for APFCR relay.\n
581 4.032 Continue above\nB) Bus Coupler - 1Nos. :\n3200 AMPS , 65 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole ACB with out protection 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications. 1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse. TNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\nC) Outgoing - Part - A \n1 Nos. of 1600 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n4 Nos. of 1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.
582 4.033 \nContinue above\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\nD) Outgoing - Part - B\n1Nos. of 1600 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. -1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n
583 4.034 Continue above\n4 Nos. of 1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n1Nos 400 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 400/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\n 1 Each.
584 4.035 \nMain MV panel - 4\nSupply, Installation, Testing and Commissioning of Medium Voltage floor mounting Cubicle Type Single bus bar system Panel Board suitable for 415 V, 3 Phase, 50 Hz Power Distribution System with the following mounting complete as per specifications attached.\nA) Incomer - Transformer 7 & 8 :\n3200 AMPS ACB, 65 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping . as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Maximum Demand Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n1No - Multi control relay for contorl of Under voltage, Over voltage, Single phase preventor, Phase rotation, Reverse Power with control fuses wiring etc.\n3Nos. - 3200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1 No. - CDG11 Earth Fault relay \n4 No. 3200/5A 5P10 15VA Current transformer with CT short link terminal block for Earth fault relay\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\n3 No. 3200/5A CL-1, 15VA Current transformer with CT short link terminal block for APFCR relay.\n
585 4.036 \nContinue above\nB) DG Incomer 1 & 2 :\n2500 AMPS ACB, 65 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,ShutterAssembly,Racking interlock Manual /Electrical closing& tripping . as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 2500/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1 No. - CDG11 Earth Fault relay \n1No - Multi control relay for contorl of Under voltage, Over voltage, Single phase preventor, Phase rotation, Reverse Power with control fuses wiring etc.\n4 No. 2500/5A 5P10 15VA Current transformer with CT short link terminal block for Earth fault relay\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\nC) Bus Coupler - 1Nos. :\n3200 AMPS , 65 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole ACB with out protection 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\n
586 4.037 \nContinue above\nD) Outgoing - Part - A\n1Nos. of 1600 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1 No. of 1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n2 No. of 1000 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1000/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n\n
587 4.038 \nContinue above\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 630/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\n2 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\nE) Outgoing - Part - B\n1Nos. of 1600 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n
588 4.039 \nContinue above\n3Nos. - 1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1Nos. of 1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n1Nos. of 800 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 800/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\n4Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n
589 4.04 \nContinue above\n4 Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 630/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\n2 Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, with communication port RS 485 having MODBUS Protocol with control fusese etc for each feeder\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for each feeder Multi function Meter.\nG) Busbar :\n3200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves.\nNote: To be provide 1No+1Nc potential free contact terminal block with wiring for all incoming and outgoing breakers for BMS.Electrical & Mechanical Interlock to be provide for all incomer and buscoupler.PLC Automatic EB and DG changeover system to be provide as per the logic ref.main SLD.\nAutomatic Fire extinguiser arrangement to be provide for all incomer and outgoing feeder compartment as per the CEA & CEIG norms.\n 1 Each
590 4.041 \nMLSB \nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protect\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 630/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n630A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
591 4.042 \nMPSB \nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 630/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n5Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n630A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. 1 Each
592 4.043 \nMain feeder piller-1 \nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer:\n1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n12 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n1250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
593 4.044 \nMain feeder piller-2\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer:\n800 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 800/5A CL-1 ,15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n8 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n800A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
594 4.045 \nMain AHU panel-1 ( for hall 1,2,3&4)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1000 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1000/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter.\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n2 Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n8 Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n1000A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
595 4.046 \nMain AHU panel - 2 (for exhibition hall - 5 & conventional hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1000 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type , TP&N , Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1000/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lam ps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n2 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n6 Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n1000A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
596 4.047 \nMain AHU panel - 3 (conference hall & pre function lobby)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 400 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 50 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 400/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n400A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
597 4.048 \nAHU Panel - 1 (Exhibition hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
598 4.049 \nAHU panel - 4,6 (Exhibition hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n5Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 2 Each
599 4.05 \nAHU panel - 2,3,5,7,8 (Exhibition hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 5 Each
600 4.051 \nAHU panel - 1,2 (Exhibition hall-5)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n6Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 2 Each
601 4.052 \nAHU panel - 3,4 ,5 6(convention hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 4 Each
602 4.053 \nAHU panel - 1 (pre function lobby & conference hall-1)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n4Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
603 4.054 \nAHU panel - 2 (conference hall - 2&3)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n5Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
604 4.055 \nMain AHU & ventilation panel -5 (Utility block)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n8Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n400A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
605 4.056 \nMain ventilation panel\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer 1 & 2 \n1250 AMPS ACB, 50 KA (Ics) Manual operated Draw Out ( MDO )Type Four Pole Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nB) Outgoing :\n2 Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2 Nos 400 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n2 Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n1250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n\n 1 Each
606 4.057 \nSub main ventilation panel - 1 (GF exhibition hall-1,2,3&4)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 630/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n5Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n630A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n 1 Each
607 4.058 \nSub main ventilation panel - 2 (ff exhibition hall-5, convention hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 315 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 315/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n4Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n315A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
608 4.059 \nSub main ventilation panel - 3 (terrace)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n2Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
609 4.06 \nVentilation panel - 1,2,3&4 (exhibition hall-1,2,3&4)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n9Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 4 Each
610 4.061 \nVentilation panel - 5 (exhibition hall-5 )\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n6Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n\n 1 Each
611 4.062 \nVentilation panel - 6 (convention hall )\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n11Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
612 4.063 \nVentilation panel - 7 (conference hall )\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n9Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n 1 Each
613 4.064 \nTerrace ventilation panel - 1 & 2 (terrace floor )\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n11Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n 2 Each
614 4.065 \nMLCP ventilation panel - 1 (GF): Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.\nB) Outgoing :\n10Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 2 Each
615 4.066 \nMLCP ventilation panel - 2 (4f): Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\nB) Outgoing :\n8Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n 2 Each
616 4.067 \nMain lift panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 630 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 630/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.B) \nOutgoing :\n8Nos. 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n630A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n 1 Each
617 4.068 \nMain pump panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer :\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.\nB) Outgoing :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n5Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n4Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
618 4.069 \nPump panel -2 (rain water storage & harwesting)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 63/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n8Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n63A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
619 4.07 \nPrimary pump panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : \n1Nos 125 Amps 4P Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n9Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
620 4.071 \nSecondary pump panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : \n1Nos 400 Amps 4P Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. -400/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n5Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar : \n400A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
621 4.072 \nUPS outgoing panel-1: Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : \n1Nos 100 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection. \nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set. - of Digital Volt meter (0-10V) with protection fuse for potential circuit connected with neutral busbar to earth bar.\nB) Outgoing :\n6Nos 32 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :100A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
622 4.073 \nUPS outgoing panel-2 : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : \n1Nos 63 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 63/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\n1Set. - of Digital Volt meter (0-10V) with protection fuse for potential circuit connected with neutral busbar to earth bar.\nB) Outgoing :\n6 Nos 32 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n 1 Each
623 4.074 \nEmergency lighting panel-1 : \nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : 1Nos 63 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nB) Outgoing :\n8Nos 32 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n63A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
624 4.075 \nEmergency lighting panel-2 : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : \n1Nos 32 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nB) Outgoing :\n6Nos 16 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n32A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
625 4.076 \nEmergency lighting panel-3 : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : \n1Nos 25 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nB) Outgoing :\n4Nos 16 Amps TP+2N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n32A TP+2N Copper Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
626 4.077 \nUtility panel : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : \n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 125/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n4Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n3Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n125A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n 1 Each
627 4.078 LSSB- 1 (ground floor hall - 1,2,3&4)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\nB) Outgoing :\n12Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\n 1 Each
628 4.079 LSSB- 2 (FF HAall-5, CONVENTION HALL, CONFERENCE HALL-1,2&3)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\nB) Outgoing :\n14Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
629 4.08 \nLSSB- 3 (Multi level car parking) : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 100/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n9Nos 32 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n100A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 1 Each
630 4.081 \nPSSB- 1 (GF. hall 1,2,3&4) : Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer :\n1Nos 160 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 160/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n7Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n160A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status\n 1 Each
631 4.082 \nPSSB- 2 (ff hall-5, convention hall, conference hall)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer :\n1Nos 200 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection. \nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 200/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n7Nos 63 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\n1Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n200A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status\n 1 Each
632 4.083 \nSub feeder piller - for hall - 1, 2 & 3,4,5 & convention hall\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed \nA) Incomer : 1 & 2\n1Nos 250 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 35 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 250/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit..\nB) Outgoing :\n10Nos 125 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA Short Circuit Rating with Thermal O/L and Magnetic S/C Protection.\nC) Busbar :\n250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status. \n 16 Each
633 4.084 \nChangeover panel 1250A (indoor type) (ACOS-1,2,3,4,5,6)\nDesign, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed\nA) Incomer : EB & DG\n2 Nos. of 1250 AMPS ACB, 50 KA (Ics) AC Motor operated Draw Out ( EDO )Type Four Pole TM relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications,closing& tripping as specified in the technicalSpecifications.\nThere shall be one set of Metering Compartment incorporated with the following:- \n1Set. - 3Nos. of R,Y,B phase indicating lamps with protection fuse for potential circuit.. \n1Set.- ON, OFF, Trip indication lamp for breaker status with protection fuse.\nTNC switch for breaker ON, OFF, Trip & Auto Manual Selector switch for selection of auto and manual mode.\nb) Busbar :\n1250A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves and provide 1NO+1NC contact in the incomer feeder for BMS status.\nNote: Electrical & Mechanical interlock to be provied for two incomer and Auto changeover system to be provided for the same.\n\n 6 Each
634 4.085 \nSFU with enclosure\nDesign, supply, fixing, testing and commissioning of following switch gear with suitable metal enclosure, adopter box to receive suitable rating of incoming and outgoing cable, fixing angle frame, anchor fastner all accossories etc.\n
635 4.086 100Amps TPN SFU. 4 Each
636 4.087 63Amps TPN SFU. 4 Nos.
637 4.088 32Amps TPN SFU. 4 Nos.
638 4.089 600KVAR CAPACITOR PANEL 1, 2, 3 & 4 FOR 2000KVA TRANSFORMER :\nSupply, Installation, Testing and Commissioning of Medium Voltage floor mounting Cubicle Type Distribution Board suitable for 415 V, 3 Phase, 50 Hz Power Distribution System with the following mounting complete as per specifications attached including necessary control wiring for automatic correction of capacitors ( 16 Stage ) and as specification.\nIncomer:\n1600 AMPS ACB, 50 KA (Ics) AC Motor operated Draw Out ( EDO )Type ,TP&N, Microprocessor based relay having Over current, short circuit with time setting and 6NO + 6 NC,indication for test,service,isolated ON/OFF tripindications, ShutterAssembly,Racking interlock Manual /Electrical closing& tripping as specified in the technical Specifications.\nThere shall be one set of Metering Compartment incorporated with the following:-\n1 Set of R Y B LED Type Indicating Lamps with HRC fuses and toggle switches .\n1 No 16 Stage Automatic Power factor correction relay for automatic correction of Power factor.\n1No - Class 1.0, Digital Multifunction Meter with Inbuilt Selector Switch, communication port RS 485 having MODBUS Protocol with control fusese etc.\n3Nos. - 1600/5A CL-1, 15VA current transformer with CT short link terminal block for Multi function Meter\nBusbars\n1600A TPN Aluminium Busbar with heat shrinkable colour insulated PVC sleeves.\nOUTGOING:\n3 sets of 100 KVAR capacitor bank each comprising of:\ni) 1 no. 400 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 100KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 100 KVAR MPP-H based capacitor\niv) 1 No. 100 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps.\n 4 Nos.
639 4.09 Continue above\n3 sets of 50 KVAR capacitor bank each comprising of: \ni) 1 no. 200 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 50KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 50 KVAR MPP-H based capacitor\niv) 1 No. 50 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps. \n2 sets of 25 KVAR capacitor bank each comprising of:\ni) 1 no. 100 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 25KVAR 3 Pole Capacitory Duty contactor \niii) 1 No. 25 KVAR MPP-H based capacitor \niv) 1 No. 25 KVAR 7% Detuned Reactor.\n v) 1 Set of ON/ OFF push button and indicating lamps. \n2 sets of 20 KVAR capacitor bank each comprising of:\ni) 1 no. 100 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 20KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 20 KVAR MPP-H based capacitor\niv) 1 No. 20 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps. \n2 sets of 15 KVAR capacitor bank each comprising of:\ni) 1 no. 63 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection\nii) 1 No 15KVAR 3 Pole Capacitory Duty contactor \niii) 1 No. 15 KVAR MPP-H based capacitor
640 4.091 Continue above\n2 sets of 10 KVAR capacitor bank each comprising of:\ni) 1 no. 40 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 10KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 10 KVAR MPP-H based capacitor\niv) 1 No. 10 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps.\n2 sets of 5 KVAR capacitor bank each comprising of:\ni) 1 no. 32 A TP Fixed Type MCCB with manual closing mechnism of 35 kA rating with Thermal and Magnetic Short Circuit Protection \nii) 1 No 5KVAR 3 Pole Capacitory Duty contactor\niii) 1 No. 5 KVAR MPP-H based capacitor\niv) 1 No. 5 KVAR 7% Detuned Reactor.\nv) 1 Set of ON/ OFF push button and indicating lamps.
641 4.092 Bus duct\nSupply,Erection,Testing and Commissioning of 3200 A TPN 433v, 50HZ, Air cooled insulated LV BUS duct comprising of TPN Aluminium Busbar, necessary right angle bends, Adapter chambers, 25 x 6mm twin copper earth bus for the entire length of the bus duct. The busduct shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc., from 2000KVATransformer secondary side to MV panel 3&4. (As per the detailed Technical Specification enclosed.) OUTDOOR 18 Meter
642 4.093 Supply,Erection,Testing and Commissioning of 3200 A TPN 433v, 50HZ, Air cooled insulated LV BUS duct comprising of TPN Aluminium Busbar, necessary right angle bends, Adapter chambers, 25 x 6mm twin copper earth bus for the entire length of the bus duct. The busduct shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc., from 2000KVATransformer secondary side to MV panel 3&4. (As per the detailed Technical Specification enclosed.) INDOOR 42 Meter
643 4.094 Supply,Erection,Testing and Commissioning of 1600 A TPN 433v, 50HZ, Air cooled insulated LV BUS duct comprising of TPN Aluminium Busbar, necessary right angle bends, Adapter chambers, 25 x 6mm twin copper earth bus for the entire length of the bus duct. The busduct shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc., from MV panel 3&4 to APFC panel 600KVAR(As per the detailed Technical Specification enclosed.) INDOOR. 53 Meter
644 4.095 Supply,Erection,Testing and Commissioning of 3200A Aluminium Flexible expansion joints ( Air cooled insulated ) at the Transformer side and MV panel side with required Standard Accessories etc., complete as required for one set. 8 Set
645 4.096 Supply,Erection,Testing and Commissioning of 1600A Aluminium Flexible expansion joints ( Air cooled insulated ) at the Transformer side and MV panel side with required Standard Accessories etc., complete as required for one set. 8 Set
646 4.097 Distribution boards\nMain building LDB & ELDB :\n8W TPN MCB LDB for main endrance & lobby :Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 24 Nos 6 A SP MCB . \n 1 Each
647 4.098 6W TPN MCB LDB FOR service area GF, GF mf ahu room, exhibition hall-1,2,3 : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 18 Nos 6 A SP MCB . \n 8 Each
648 4.099 4W TPN MCB LDB FOR GF EXHIBITION HALL - 4 : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB . \n 1 Each
649 4.1 4W TPN MCB ELDB for ff service area : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB Outgoing : 12 Nos 6 A SP MCB .\n 5 Each
650 4.101 12W TPN MCB LDB for ff main endrance & lobby, conference hall-1 : \nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 12 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 36 Nos 6 A SP MCB . \n 2 Each
651 4.102 8W TPN MCB ELDB for ff convention hall, conference hall-2 :\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 24 Nos 6 A SP MCB. \n 2 Each
652 4.103 6W TPN mcb LDB for ff exhibition hall 5, convention hall & ff ahu room :Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 18 Nos 6 A SP MCB . \n 3 Each
653 4.104 4W TPN MCB LDB for ff service area : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB\n 4 Each
654 4.105 6W TPN MCB ELDB for GF conference hall: Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 18 Nos 6 A SP MCB. \n 3 Each
655 4.106 4W TPN MCB ELDB for ff service area, exhibition hall-5, convention hall :\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB\n. 3 Each
656 4.107 MLCP LDB & ELDB: \n12W TPN MCB LDB for GF MLCP : \nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 12 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 36 Nos 6 A SP MCB .\n 1 Each
657 4.108 8W TPN MCB LDB for ff to 6th fl. MLCP : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 24 Nos 6 A SP MCB. \n 6 Each
658 4.109 12W TPN MCB ELDB for MLCP : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 12 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer : 3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 36 Nos 6 A SP MCB 1 Each
659 4.11 Utility building LDB & ELDB\n8W TPN MCB LDB for GF & ff Utility building\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 24 Nos 6 A SP MCB. 2 Each
660 4.111 4W TPN MCB ELDB for GF & ff Utility building : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 32 A, 4P MCB\nSub Incomer :3 Nos 32 A DP MCBs with 30mA ELCB\nOutgoing : 12 Nos 6 A SP MCB. 1 Each
661 4.112 Distribution Boards-power distribution board\n4W TPN MCB PDB for GF service area & main lobby : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs with 100mA ELCB\nOutgoing : 12 Nos 16/20 A SP MCB.\n 5 Each
662 4.113 4W TPN MCB PDB for 1f service area & main lobby : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs with 100mA ELCB\nOutgoing : 12 Nos 16/20 A SP MCB. \n 4 Each
663 4.114 6W TPN MCB PDB for 1f service area & main lobby : Fabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs with 100mA ELCB\nOutgoing : 18 Nos 16/20 A SP MCB . \n 1 Each
664 4.115 Distribution Boards-UPS : \n8W TPN MCB UPSDB GF service area\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 8 WAY TP & N MCB Distribution Board with 'D' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs \nOutgoing : 24 Nos 16/20 A SP MCB. \n
665 4.116 6W TPN MCB UPSDB GF service area, GF exhibition hall, ff convention hall, ff conference hall, ff service area \nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 6 WAY TP & N MCB Distribution Board with 'D' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs \nOutgoing : 18 Nos 16/20 A SP MCB. \n 2 Each
666 4.117 4W TPN MCB UPSDB GF service area, GF exhibition hall, ff convention hall, ff conference hall, ff service area :\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'D' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs \nOutgoing : 12 Nos 16/20 A SP MCB.\n 4 Each
667 4.118 Utility building UPS DB :\n4W TPN MCB UPSDB GF utility building :\nFabrication, Supply, Installation, Testing and Commissioning of Phase Segregated Type 4 WAY TP & N MCB Distribution Board with 'D' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB\nSub Incomer :3 Nos 63 A DP MCBs \nOutgoing : 12 Nos 16/20 A SP MCB. \n 1 Each
668 4.119 VTPN ventilation distribution boards:\n12W VTPN ventilation db for exhibition hall-1,2,3,4 & 5 :\nFabrication, Supply, Installation, Testing and Commissioning of Vertical type 12 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB \nOutgoing : 12Nos 6/10 A TP MCB. \n 5 Each
669 4.12 8W VTPN ventilation db for ff convention hall & conference hall : Fabrication, Supply, Installation, Testing and Commissioning of Vertical type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB \nOutgoing : 8Nos 6/10 A TP MCB. \n 3 Each
670 4.121 8W VTPN MCB PDB for utility : Fabrication, Supply, Installation, Testing and Commissioning of Vertical type 8 WAY TP & N MCB Distribution Board with 'C' curve MCB's and double door, dust & vermin proof and copper bus bar comprising of the following : \nIncoming : 1No 63 A, 4P MCB \nOutgoing : 8Nos 6 A TP MCB. \n 2 Each
671 4.122 VTPN distribution boards : \nLIFT DB : Supplying and fixing of sheet steel, MCB distribution board, 415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. for LIFT DB for Main Hall, MLCP, Restaurant.comprising of the following : \nIncoming : 1No 63 A, 4P MCB \nOutgoing : 1Nos 40 A TP MCB \nOutgoing : 2Nos 16 A TP MCB. \n \n 15 Each
672 4.123 UPS & Inverter :\nSupply and Erection of 80 KVA UPS Systems with 3-phase input and Three phase output. Maintanance free batteies suitable for backup system should have Half an hour continous rating.The scope includes providing neccesary battery stand , inter connecting cables from UPS battery.The scope also includes providing neccesary by-pass arrangement and all other requirements. The capacity of the battery shall be of 12V DC with a minimum of Suitable ampere hour and as per specification. \n 1 Each
673 4.124 Supply and Erection of 60 KVA UPS Systems with 3-phase input and Three phase output. Maintanance free batteies suitable for backup system should have Half an hour continous rating.The scope includes providing neccesary battery stand , inter connecting cables from UPS battery.The scope also includes providing neccesary by-pass arrangement and all other requirements. The capacity of the battery shall be of 12V DC with a minimum of Suitable ampere hour and as per specification. \n 1 Each
674 4.125 Supply and Erection of 50 KVA Inverter Systems with 3-phase input and Three phase output. Maintanance free batteies suitable for backup system should have Half an hours continous rating.The scope includes providing neccesary battery stand , inter connecting cables from Inverter battery.The scope also includes providing neccesary by-pass arrangement and all other requirements. The capacity of the battery shall be of 12V DC with a minimum ofSuitable ampere hour and as per specification. \n \n 1 Each
675 4.126 Supply and Erection of 15 KVA Inverter Systems with 3-phase input and Three phase output. Maintanance free batteies suitable for backup system should have Half an hours continous rating.The scope includes providing neccesary battery stand , inter connecting cables from Inverter battery.The scope also includes providing neccesary by-pass arrangement and all other requirements. The capacity of the battery shall be of 12V DC with a minimum of Suitable ampere hour and as per specification. \n 1 Each
676 4.127 LT cabling & end termination :\nSupply and Laying of PVC insulated,XLPE, aluminium conductor, 1.1 KV grade armoured, MV cable of the following sizes as required, generally conforming to IS:7098 Part-I\n
677 4.128 3 1/2 X 400 sqmm. 1495 Metre
678 4.129 3 1/2 X 300 sqmm. 5021 Metre
679 4.13 3 1/2 X 240 sqmm. 4743 Metre
680 4.131 3 1/2 X 185 sqmm. 738 Metre
681 4.132 3 1/2 X 150 sqmm. 1392 Metre
682 4.133 3 1/2 X 120 sqmm. 855 Metre
683 4.134 3 1/2 X 95 sqmm. 1465 Metre
684 4.135 3 1/2 X 70 sqmm. 1493 Metre
685 4.136 3 1/2 X 50 sqmm. 421 Metre
686 4.137 4 x 25 sqmm. 5733 Metre
687 4.138 4 x 16 sqmm . 4368 Metre
688 4.139 4 x 10 sqmm . 154 Metre
689 4.14 4 x 2.5 sqmm . 685 Metre
690 4.141 5Runs of 25Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 10 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA INVERTER GF) and (45 KVA INVERTER 1F)\n 40 Metre
691 4.142 5Runs of 10Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 6 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA AND 45KVA UPS UPS O/G DBs)\n 516 Metre
692 4.143 5Runs of 6Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 4 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA AND 45KVA UPS UPS O/G DBs)\n 1307 Metre
693 4.144 TERMINATION :\nSupplying and making end termination with brass Double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV\n
694 4.145 3 1/2 X 400 sqmm. 22 Set
695 4.146 3 1/2 X 300 sqmm. 168 Set
696 4.147 3 1/2 X 240 sqmm. 68 Set
697 4.148 3 1/2 X 185 sqmm. 16 Set
698 4.149 3 1/2 X 150 sqmm. 18 Set
699 4.15 3 1/2 X 120 sqmm. 16 Set
700 4.151 3 1/2 X 95 sqmm. 20 Set
701 4.152 3 1/2 X 70 sqmm. 16 Set
702 4.153 3 1/2 X 50 sqmm. 10 Set
703 4.154 4 x 25 sqmm. 66 Set
704 4.155 4 x 16 sqmm . 86 Set
705 4.156 4 x 10 sqmm . 4 Set
706 4.157 4 x 2.5 sqmm . 16 Set
707 4.158 5Runs of 25Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 10 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA INVERTER GF) and (45 KVA INVERTER 1F) 4 Set
708 4.159 5Runs of 10Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 6 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA AND 45KVA UPS UPS O/G DBs) 12 Set
709 4.16 5Runs of 6Sq.mm. PVC Insulated stranded copper conductor wires ( One each for Phase, 2 Neutral ) with 1Run of 4 Sq.mm. PVC Insulated multi stranded copper conductor wires for continuous earthing in 2.0 mm. thick MS Conduits laid in surface conduits (15KVA AND 45KVA UPS UPS O/G DBs) 20 Set
710 4.161 Perforated cable tray &M.S items : \nSupply, erection of following sizes GI ladder type cable rack system made out of sheet steel folded to required shape with adequate number of supports. (Cable tray support price is not required in this Items).\nThe cable tray shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable tray shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc. The tray shall have suitable cable clamping arrangements etc.
711 4.162 150 mm Width X 75mm Height X 3mm Thick. 710 Metre
712 4.163 300 mm Width X 75mm Height X 3mm Thick. 795 Metre
713 4.164 450 mm width X 75mm Height X 3mm Thick. 650 Metre
714 4.165 600 mm.width X 75mm Height X 3mm Thick. 160 Metre
715 4.166 900 mm width X 100mm Height X 3mm Thick. 1455 Metre
716 4.167 1000 mm width X 100mm Height X 3mm Thick. 690 Metre
717 4.168 Supply and erection of M.S. Material for ladder type cable trays, cable supports, SB, DB's supports, iron embeded in the wall, steel structure in open Area painted with two coats of primer and two coats of enamel paint. Substation to main panel room , ahu room and lighting conduit trays and suspensions of lighting conduit . \n 16305 kgs
718 4.169 MS chequer plate : \nDesign, cutting, and fixing of 6 mm thick chequered plate with required MS angles for closing around the cable tray shafts and communication shafts. It should be covered with neatly without any gap around the cable tray as per IE Regulation. The gap between cable tray and the chequred plate shall be covered with insulating materials. \n 120 sqm
719 4.17 Internal wiring for main building : \nWiring for dependent 6 A, 3 Pin Socket outlet with 2 x 1.5 sqmm FRLS PVC insulated Stranded Copper conductor Cable and 1 x 1.5 sqmm FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire, in the lighting switch board, 6 Amps modular type Single Way Switch, 6 A 5 pin, modular type shuttered socket outlet including making connections etc., as per specification \n 11 Each
720 4.171 \nWiring for Lift Well Light Point and socket oulet with 2 x 1.5 sqmm FRLS PVC insulated Stranded Copper Conductor Cable along with 1 x 1.5 sqmm FRLS PVC insulated Stranded copper conductor cable as earth wire in surface MS conduit including providing and fixing Galvanised / Cadmium plated MS switch box, 2 no 6A Single Way Modular Switch for (controlling light point and socket Outlet) , 1 No 6 A 5 Pin shuttered modular socket outlet with modular switch plate and making necessary connections etc., as per specification (6 Meters shall be considered for Wires & conduit per point.)\n 80 Point
721 4.172 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required. (Raw Power)\n 58 Each
722 4.173 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2/3 pin 5/6 A modular Shuttered socket outlet and 5/6 A modular switch, connections etc. as required. (Raw Power)\n 2 Each
723 4.174 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required for Hand Dryer. (Raw Power)\n 17 Each
724 4.175 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required for Napkin Vending Machine. (Raw Power)\n 11 Each
725 4.176 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2/3 pin 5/6 A modular Shuttered socket outlet and 5/6 A modular switch, connections etc. as required. (UPS Power)\n 30 Each
726 4.177 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and 3 no of fixing 2/3 pin 5/6 A modular Shuttered socket outlet and 1 no of 16 A modular switch, connections etc. as required.(UPS Power)\n 35 Each
727 4.178 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required for (UPS Power)\n 44 Each
728 4.179 Wiring for power :\nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.\n
729 4.18 2 x 2.5 sqmm +1 x 1.5 sqmm (E) 9081 Metre
730 4.181 2 x 4 sqmm +1 x 2.5 sqmm (E) 1385 Metre
731 4.182 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
732 4.183 25 mm 9240 Metre
733 4.184 Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required:
734 4.185 25 mm 1500 Metre
735 4.186 MS conduit wiring (for lighting): \nWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel\nconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.\n
736 4.187 Group A (One light controlled by one switch - 6mtrs ) 46 Each
737 4.188 Group B (Two light controlled by one switch - 9mtrs) 66 Each
738 4.189 Group C (Three light controlled by one switch - 12mtrs) 132 Each
739 4.19 Run of main wiring for circuit / power / sub main etc :\nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.
740 4.191 2 x2.5 sqmm + 1 x 1.5 sqmm (E) 7208 Metre
741 4.192 Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required:
742 4.193 25 mm. 4753 Metre
743 4.194 (LDB to Group controlled Light & ELDB to Group controlled Light) : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.
744 4.195 2 x2.5 sqmm + 1 x 1.5 sqmm (E) 34984 Metre
745 4.196 Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required:
746 4.197 25 mm. 22962 Metre
747 4.198 Internal wiring for MLCP : \nWiring for dependent 6 A, 3 Pin Socket outlet with 2 x 1.5 sqmm FRLS PVC insulated Stranded Copper conductor Cable and 1 x 1.5 sqmm FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire, in the lighting switch board, 6 Amps modular type Single Way Switch, 6 A 5 pin, modular type shuttered socket outlet including making connections etc., as per specification.\n 4 Each
748 4.199 \nWiring for Lift Well Light Point and socket oulet with 2 x 1.5 sqmm FRLS PVC insulated Stranded Copper Conductor Cable along with 1 x 1.5 sqmm FRLS PVC insulated Stranded copper conductor cable as earth wire in surface MS conduit including providing and fixing Galvanised / Cadmium plated MS switch box, 2 no 6A Single Way Modular Switch for (controlling light point and socket Outlet) , 1 No 6 A 5 Pin shuttered modular socket outlet with modular switch plate and making necessary connections etc., as per specification. (3 Meters shall be considered for Wires & conduit per point.)\n \n 32 Point
749 4.2 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required. (Raw Power)\n 1 Each
750 4.201 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no of 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 2 nos of 16 A modular switch, connections etc. as required for BMS (UPS Power)\n 1 Each
751 4.202 MS CONDUIT WIRING (for Lighting) :\nWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel\nconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
752 4.203 Group A (One light controlled by one switch - 6mtrs ) 43 Each
753 4.204 Group B (Two light controlled by one switch - 9mtrs) 5 Each
754 4.205 Group C (Three light controlled by one switch - 12mtrs) 1 Each
755 4.206 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.\n 4 Each
756 4.207 Run of main wiring for circuit /power / sub main etc : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.
757 4.208 2 x2.5 sqmm + 1 x 1.5 sqmm (E) 6036 Metre
758 4.209 Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required:
759 4.21 25 mm. 4435 Metre
760 4.211 (LDB to Group controlled Light &ELDB to Group controlled Light) :\nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.
761 4.212 2 x2.5 sqmm + 1 x 1.5 sqmm (E) 18352 Metre
762 4.213 Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required:
763 4.214 25 mm. 10888 Metre
764 4.215 Internal wiring for Utility building :\nSupplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular Shuttered socket outlet and 15/16 A modular switch, connections etc. as required. (Raw Power) 41 Each
765 4.216 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no of 6 pin 5/6 & 15/16 A modular Shuttered socket outlet and 2 nos of 16 A modular switch, connections etc. as required for BMS (UPS Power)\n 2 Each
766 4.217 Wiring for power : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.\n
767 4.218 2 x2.5 sqmm + 1 x 1.5 sqmm (E) 1180 Metre
768 4.219 2 x 4 sqmm + 1 x 2.5 sqmm (E) 335 Metre
769 4.22 Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required:
770 4.221 25 mm. 1510 Metre
771 4.222 MS conduit wiring (for lighting) :\nWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. \n
772 4.223 Group B (Two light controlled by one switch - 9mtrs) 41 Each
773 4.224 Group C (Three light controlled by one switch - 12mtrs) 45 Each
774 4.225 Run of main wiring for circuit /power / sub main etc : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.\n
775 4.226 2 x2.5 sqmm + 1 x 1.5 sqmm (E) 3235 Metre
776 4.227 Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required:
777 4.228 25 mm. 3015 Metre
778 4.229 (LDB to Group controlled Light &ELDB to Group controlled Light) : \nWiring with following sizes of FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS PVC insulated Stranded Cu. Conductor Cable as earth wire in Existing MS Conduit in recess/surface including making connection etc., as per specification.\n
779 4.23 2 x2.5 sqmm + 1 x 1.5 sqmm (E) 213 Metre
780 4.231 Supplying and fixing of following sizes of MS conduit along with the accessories in surface including cutting the wall and making good the same in case of recessed conduit as required:
781 4.232 25 mm. 213 Metre
782 4.233 LIGHT FIXTURES FOR MAIN BUILDING:\nSupply, Installation, testing and commissioning of prewired, 40W LED batten fittings, of all types complete with all accessories etc. directly on ceiling / wall, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For Service room, Service corridor, Electrical Room. \nModel No: Bajaj- BLTRU 40W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 223 Each
783 4.234 Supply, Installation, testing and commissioning of prewired, IP65 40W LED batten weather proof fittings, of all types complete with all accessories etc. directly on ceiling / wall, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For AHU room, Electrical Room. \nModel no :BAJAJ-BIPC 40W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 471 Each
784 4.235 Supply, Installation, testing and commissioning of round type high power recess mounting 32W LED down light fixture with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For Lobby & location room. \nModel no:BAJAJ- BCDLR 32 WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 134 Each
785 4.236 Supply, Erection, Testing and commissioning of recessed mounting LED step light fixture with driver (each 5mtrs / 1 driver) on to wall as per site requirement with necessary interconnecting wires & fixing hardwares etc. all complete as required. \nModel no: BAJAJ-75W PROFESSIONAL LED STRIP IP65 WW (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 1774 Metre
786 4.237 Supply, Installation, testing and commissioning of sleek round recess mounting 18W LED down light with all accessories etc.,directly on to the false ceiling (including modifying the false ceiling openings and making good the same) and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For corridor, & Toilet, \nModel no: BAJAJ- BGSLO 18 W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 235 Each
787 4.238 Supply, Installation, testing and commissioning of recessed mounting 120W LED Hige Bay linear light fixture with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For toilet cubicle. \nModel no: BAJAJ-BTHBX 120W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 444 Each
788 4.239 Supply, Installation, testing and commissioning of recess mounting linear with minimalistic shape 72w - 8Ft. LED down light with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. \nModel no: BAJAJ-BRTX 2-40W LED 8F WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 81 Each
789 4.24 Supply, Installation, testing and commissioning of sleek round recess mounting 18W LED down light with all accessories etc.,directly on to the false ceiling (including modifying the false ceiling openings and making good the same) and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For corridor, & Toilet, \nModel no: BAJAJ-BZSLO 18 W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 36 Each
790 4.241 Supply, Installation, Testing and commissioning of recessed mounted white powder coated CRCA sheet LED 600 x 600mm square light fixture directly mounted on the false ceiling including modifying the falseceiling opening and making good the same including stay wire, anchor fastner,interconnection with 2.5 sq. mm, FRLS PVC insulated copper conductor single core cable etc. complete as required. For Exhibition Hall area \nModel no: BAJAJ- BZRSQL 36W GZI WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 218 Each
791 4.242 Supply, Installation, testing and commissioning of 40W recessed down light fixture and accessories etc.,directly fixed on the false ceiling including modifying the false ceiling openings and making good the same and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. \nModel No: PhilipS-RS391 LED30S 5000 PSU (or) Equivalent in Bajaj make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent Model no in Crompton make\n 88 Each
792 4.243 Supply, Installation, testing and commissioning of 36W recessed down light fixture and accessories etc.,directly fixed on the false ceiling including modifying the false ceiling openings and making good the same and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. \nModel no: BAJAJ-BAJAJ BRWSQ 36W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 113 Each
793 4.244 Supply, Installation, testing and commissioning of 7W recessed down light fixture and accessories etc.,directly fixed on the false ceiling including modifying the false ceiling openings and making good the same and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required\nModel no: BAJAJ-BGSLO Sleek 6W WH RD (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 139 Each
794 4.245 Supply, Installation, testing and commissioning of 3W suspended light fixture and accessories etc.,directly hanging on the true ceiling including wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required.\nModel no:PhilipS-58074 WITH 3W LED BULB (or) Equivalent in Bajaj make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 14 Each
795 4.246 Supply, Installation, testing and commissioning of 36W LED lamp suspended tecorative chandlier light fixture, supporting stay wire from the true ceiling, anchor fastner, and accessories etc.,and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required.\nModel no :PhilipS-36898 treasure ceiling lamp led Gold (or) Equivalent in Bajaj make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make \n 41 Each
796 4.247 Supply, Installation, testing and commissioning of 80 Led lamp suspended tecorative chandlier light fixture, supporting stay wire from the true ceiling, anchor fastner, and accessories etc.,and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper Conductor, single core cable as required.\nModel no :PhilipS-mimosa 45116 (or) Equivalent in Bajaj make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make 9 Each
797 4.248 Supply, Installation, testing and commissioning of Die Cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket Bulk head Light fittings with 10W CFL lamp and accessories etc.,directly fixed on the wall and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For Lift Well. \nModel no: BAJAJ- BJDB 10 CFL RF(or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make 80 Each
798 4.249 LIGHT FIXTURES FOR MLCP:\nSupply, Installation, testing and commissioning of prewired, 40W LED batten fittings, of all types complete with all accessories etc. directly on ceiling / wall, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For car park area.\nModel no: BAJAJ-BAJAJ 14026 BLTRU 40W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 900 Each
799 4.25 Supply, Installation, testing and commissioning of round type high power surface mounting 32W LED down light fixture with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For lift Lobby\nModel no: BAJAJ- BCDLR 32 WH(or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make 186 Each
800 4.251 Supply, Installation, testing and commissioning of sleek round recess mounting 18W LED down light with all accessories etc.,directly on to the false ceiling (including modifying the false ceiling openings and making good the same) and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For corridor, & Toilet.\nModel no: BAJAJ- BGSLO 18 W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make 35 Each
801 4.252 Supply, Installation, Testing and commissioning of 1200mm ceiling fan with suspended rod bolt nut with all accessories. Etc. 4 Each
802 4.253 LIGHT FIXTURES FOR UTILITY BUILDING:\nSupply, Installation, testing and commissioning of prewired, IP65 40W LED batten weather proof fittings, of all types complete with all accessories etc. directly on ceiling / wall, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For AHU room, Electrical Room. \nModel no: BAJAJ-BIPC 40W WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 197 Each
803 4.254 Supply, Installation, testing and commissioning of round type high power Surface mounting 32W LED down light fixture with all accessories etc.,directly on to the false ceiling including modifying the false ceiling openings and making good the same and wiring and connections with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For Lobby & location room. \nModel no: BAJAJ-BCDLR 32 WH (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 8 Each
804 4.255 Supply, Installation, testing and commissioning of suspended type 150W Highbay LED down light complete with all accessories etc. directly suspended on true ceiling, including connections with 2.5 sq.mm. FRLS PVC insulated, copper conductor, single core cable etc. as required. For Stairecase areas. \nModel no: BAJAJ- BGHB 150W WH (or) Equivalent Model no in Philips make (or) Equivalent Model no in wipro make (or) Equivalent Model no in Havells make (or) Equivalent Model no in Crompton make\n 12 Each
805 4.256 Supply, Installation, testing and commissioning of Die Cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket Bulk head Light fittings with 10W CFL lamp and accessories etc.,directly fixed on the wall and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. For terrace area. \nModel no: BAJAJ-BJDB 10 CFL RF (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 28 Each
806 4.257 Supply, Installation, testing and commissioning of LED street light with pressure die cast housin alon with prismatic polycarbonate di user and with secondary optics and IP 65 protection.directly fixed on the wall including wall bracket and wiring with 2.5 sq.mm. FRLS PVC insulated, Copper conductor, single core cable as required. \nModel no: BAJAJ-BRLEP 25W WH (or) Equivalent Model no in Philips make (or) Equivalent Model no in wipro make (or) Equivalent Model no in Havells make (or) Equivalent Model no in Crompton make 4 Each
807 4.258 Earthing : \nEarthing with copper earth plate 600X600X3 mm including accessories, and providing masonry enclosure (Chamber size of 1050X1050X700) with fabricated MS Chequre plate of 600X600X6 cover with frame & keel arangement, and watering pipe 3.0 Metre long etc. with charcoal/ coke and salt as required. \nTransformer Neutral Earthing 14 Nos\nDG Neutral Earthing 0 Nos\nUPS 4 Nos: 18 NOS.
808 4.259 Earthing with C.I. earth pipe 3.0 metre long, 100 mm dia including accessories, and providing masonry enclosure (Chamber size of 1050X1050X700) with fabricated MS Chequre plate of 600X600X6 cover with frame & keel arangement, and watering pipe etc. with charcoal/ coke and salt as required. \nHT VCB Body Earthing 10 Nos \nLT panel Body Earthing 14 Nos \nTransformer Body Earthing 14 Nos\nDG set Body Earthing 0 Nos\nEPABX Earthing 2 Nos\nServer Earthing 2 Nos\nLift Earthing 36 Nos\nChiller Earthing 4 Nos \n 82 NOS.
809 4.26 Providing and fixing 25mm X 5 mm copper strip on surface or in recess for connections etc. as required. 10 Metre
810 4.261 Providing and fixing 60 mm x 10 mm copper strip on surface or in recess for connections etc. as required. 300 Metre
811 4.262 Providing and fixing 25 mm x 6 mm copper strip on surface or in recess for connections etc. as required. 1908 Metre
812 4.263 Providing and fixing 50 mm x 6 mm GI strip on surface or in recess for connections etc. as required. 6658 Metre
813 4.264 Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required. 3316 Metre
814 4.265 Providing and fixing 8 Swg cu wire on surface or in recess for connections etc. as required. 85 Metre
815 4.266 Providing and fixing 10 Swg cu wire on surface or in recess for connections etc. as required. 85 Metre
816 4.267 Lightning arrestor : \nSupply, Erection, Testing and Commissioning of lightning arrestor enchanching type designed to attract lightning from a predetermined volume and to safety convey the lightning current to the earth and complaint UL-96 (Under writers labouratories-96) and complete with following principle components.
817 4.268 Air Terminal:\nSupply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) \n : 3520 Metre
818 4.269 Folding clamp :To hold 8 mm Al conductor at every 1m dist on the top roof without any drilling on roof , Installation can be made through simple fastening system ,mainly used for seaming sheet roof application, Holds good upto \nseaming thickness of upto 20mm . 2328 Nos.
819 4.27 Supply of Roof conductor holder for parapet- Polyamide Conductor holder:\nWith M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance\n 752 Nos.
820 4.271 Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. \n 350 Nos.
821 4.272 Providing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . \n 140 Nos.
822 4.273 Providing of expansion piece with connector: For equalising temperature related length changes.Necessary on conductors length over 20 meters.For round conductor Rd 8/ALU. \n 101 Nos.
823 4.274 Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ).\n 202 Nos.
824 4.275 Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC 62305 part-3 16mm rod tapered to 10 mm aluminium rod : \nMeets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) \n4Metre Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. 4 Nos.
825 4.276 Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC 62305 part-3 16mm rod tapered to 10 mm aluminium rod : \nMeets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) \n 2Metre Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. 13 Nos.
826 4.277 Accessories : System consist of Fang Fix with base and clamp, on the top air terminal is erected. 4 Nos.
827 4.278 Accessories : System consist of Fang Fix with base and clamp, on the top air terminal is erected. 8 Nos.
828 4.279 Down Conductor :\nSupply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185- 305 (IS/IEC 62305) \n 1135 Metre
829 4.28 Supply of Roof conductor holder for parapet- Polyamide Conductor holder:\nWith M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance 1135 Nos.
830 4.281 Supply of Roof conductor holder for parapet- Polyamide Conductor holder:\nWith M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance \n 40 Metre
831 4.282 Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6.\n 2 Nos.
832 4.283 Earthing Pit :\nSupply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directlyin ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx:70 micron\ncoating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding. \n 850 Metre
833 4.284 Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. 70 Nos.
834 4.285 Providing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts. 40 Nos.
835 4.286 Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. 5 Nos.
836 4.287 Supply of CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 40 Metre
837 4.288 Providing The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system 40 Nos.
838 4.289 provided with universal clamp made of SS to connect rod with flat conductor 40 Nos.
839 4.29 Providing the above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system 40 Nos.
840 4.291 Street / yard lighting:\nSupply , fixing, testing and commissioning of .8M height Hot dip galvanized poles, with integral control box, MCB and cable termination arrangement with top bracket. \n 68 Each
841 4.292 Supply , fixing, testing and commissioning of street light EDGE Series of LED street light luminaire 68 Each
842 4.293 Supply , fixing, testing and commissioning of street light EDGE Series of LED street light luminaire \nModel no :BAJAJ-BRTFG Series of Lights (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 54 Each
843 4.294 Supply , fixing, testing and commissioning of Bollard light luminaire \nModel no: BAJAJ-BGBOL 605 9W LED (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 1 Each
844 4.295 Supply , fixing, testing and commissioning of Recessed Ramp light luminaire \nModel no: Havells-LHESABPBUN6E008 8 W (or) Equivalent in Philips make (or) Equivalent in wipro make (or) Equivalent in Havells make (or) Equivalent in Crompton make\n 70 Each
845 4.296 Supply, Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4Cx25sqmm Aluminium armoured cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requried. 3350 Metre
846 4.297 Supply, Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4Cx4sqmm copper armoured cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requried. 2120 Metre
847 4.298 Safety equipments :\nSupply and installing the following items as per local Electrical Inspectorate's requirement.
848 4.299 12 mm thick rubber mat. 384 Sq. Mt.
849 4.3 Fire Buckets stand suitable for 4 Nos. fire buckets with Fire Buckets filled with stand.. 10 Each
850 4.301 First Aid Box with stand. 10 Each
851 4.302 Shock Treatment Chart in 2 Language (Local Language and English) 5 Each
852 4.303 Supply & Fixing HT cable route marker with 10cm. x 10cm. 5mm thick G.I.plate with inscription thereon, bolted/ welded to 35mm x 35mm x 6mm angle iron, 60 cm. long and fixing the same in ground as required. 10 Each
853 4.304 Supply and fixing of 11KV Al Danger Boards of size 12" x 8" both in Tamil and English 5 Each
854 4.305 Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English 5 Each
855 4.306 Supply of 11 KV Tested Gloves with Box filled with chalk powder. 2 Set
856 4.307 Supply and erection of fire extinguisher Co2 4.5 Kg. confirm to IS norms. 2 Each
857 4.308 TNEB AND CEA APPROVALS :\nCEA : \nPreparation of drawings and submission to the statutory authorities such as Chief Electrical Inspectorate/Central Electricity Authority, obtaining approval from all statutory authorities including energizing the Installation for Electrical Installation and for commissioning the system including arranging inspection and also necessary approval / safety certificate from authorities etc. \nThe necessary statutory fees will be paid by the client against proof of demand.\n 1 job
858 4.309 Preparation of drawings and submission to the statutory authorities such as obtaining approval from TNEB authorities including energizing the Installation for Electrical Installation and for commissioning the system. \nThe necessary statutory fees will be paid by the client against proof of demand. \n 1 job
859 4.31 MISCELLANEOUS ITEMS :\nTowards Preparation of Drawings, Getting Approval Arranging Inspection and Obtaining load sanction and from Local EB Authorities inclusive of all incidental charges. 1 job
860 4.311 Towards Preparation of Drawings, Getting Approval Arranging Inspection and Obtaining Safety Certificate from Central Electricity Authority - Chennai. 1 job
861 4.312 Preparation of AS BUILT Drawings -3 SET 1 job
862 5 ACMV WORKS
863 5.001 PLANT ROOM WITH ELECTRICAL WORKS
864 5.002 Supplying, installation, testing and commissioning of minimum capacity of 340 TR and above Air cooled screw chillers,1.25 KW/TR +/- 5% Tolerance at design condition including fans as per AHRI 550/590 standard. temperature: 6 deg C leaving and 13 deg C entering condition, at chennai ambient condition 104deg F and 83 Deg F, vibration Isolator and required adaptor box for cable termination, main disconnect switch, Plant manager integerator (consider provision for 8Nos chillers), required pressure differential sensor,incoming cable adaptor box, flow switch, Flange end coupling for inlet and outlet connection, Black Epoxy coated fins, Condenser fins covered with 12 guage SS316 mesh for mechanical protection. compressor sound jacket using Armasound material required thickness of 75mm thick with 22G Al cladding with suitable vibration isolator / Suitable sound jackets shall be provided to meet the tender conditions. \n(i) Suitable cable entry adaptor box with isolater and weather protection outdoor type panel(IP65)\n(ii) differential pressor sensor\n(iii) Vibration isolator \n(iv) Flow switch\n(v) Compressor sound jocket\n(vi) Plant Manager\n(vii) Flange end connection 6 Nos
865 5.003 Supplying,installation, testing and commissioning of Endsuction long coupled base mounted for primary pumps with bronze impeller, capacity of 649 US gpm@14m head with suitable insulation and 24g AL cladding.\nSupplying and installation of Suitable Inertia frame with Vibration mounting for the above selection of pumps.RCC M20grade pedestal to be casted as per the drawing.\nSupplying and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) and required capacity of by pass star delta starter ,Cubical type indoor panel with single incommer with Main isolator and disconnect switch for all pumps and indoor type encloser box and required BMS compatable for the above operation-7Nos of working Pumps +1 stand by pumps.\n(i) Supplying and installation of insulation for Pump casing using 30mm thick nitrile rubber insulation with 22G al cladding for the above mentioned pumps\n(ii) Supplying and applying of Enamel paint for pump base and water flow sticker. 7 Nos
866 5.004 Supplying,installation and commissioning of double suction top discharge, long coupled base mounted for Secondary pumps with bronze impeller, capacity of 1299 Usgpm@28m head,3 Sets of DPT with suitable insulation and 24g AL cladding.\nSupplying and installation of Suitable Inertia frame with Vibration mounting for the above selection of pumps.RCC M20grade pedestal to be casted as per the drawing.\nSupplying and installation for Secondary Pump with Pump logic controller for pump operation and Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) and capacity of by pass star delta starter, Cubical type Indoor panel with single incommer with suitable Main isolator, disconnect for all pumps,encloser box and BMS compatable for the above operation-4Nos of working Pumps +1 stand by pumps.\n(i) Supplying and installation of insulation for Pump casing using 30mm thick nitrile rubber insulation with 22G al cladding for the above mentioned pumps.\n(ii) Supplying and applying of Enamel paint for pump base and water flow sticker.\n(iii) Supplying and installation of 3Nos of DP sensor for pump operation with amplifier and necessary support and copper tubing between dp sensor to chilled water line.\n\n 5 Nos
867 5.005 InSulated Valves
868 5.006 Supplying,installation and commissioning of NON - Return Valve with dual plate of CI body SS plates Vulcanised NBR sea; flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.
869 5.007 250 mm dia 5 Nos
870 5.008 200 mm dia 7 Nos
871 5.009 Supplying, installation and commissioning of Metallic bellows suitable for pipes, pressure rating of PN16
872 5.01 250 mm dia 10 Nos
873 5.011 200 mm dia 26 Nos
874 5.012 Supplying, installation and commissioning of Suction Guide suitable for pipes with pressure rating of PN16-with insulation and 24g AL cladding
875 5.013 250 mm dia 5 Nos
876 5.014 200 mm dia 7 Nos
877 5.015 Motorized Butterfly Valves with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating ,conforming to BS 5155, IS 13095, with IP-55 actuator as specified.
878 5.016 250 mm dia 7 Nos
879 5.017 200 mm dia 13 Nos
880 5.018 Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
881 5.019 450 mm dia 2 Nos
882 5.02 400 mm dia 1 Nos
883 5.021 350 mm dia 2 Nos
884 5.022 300 mm dia 4 Nos
885 5.023 250 mm dia 5 Nos
886 5.024 200 mm dia 13 Nos
887 5.025 Supplying,installation of pressurised closed expansion tank with stand by motor and bms compatible -capacity of 3000 lit. for water. 100mm thick rigid puff insulation with 20G GI cladding with float valve arrangement 1 Nos
888 5.026 Supplying and installation of ms angle support for plant room. 8000 kg
889 5.027 Supplying and installation of 12mm thick Ms Checkered plate for shaft/chiller service platform closings etc. 2280 kg
890 5.028 Supplying,Laying and commissioing of PVC insulated, copper conductor FRLS 1.1kv grade, Armoured copper cable
891 5.029 1C x 240 sqmm xlpe 295 Rmt
892 5.03 4C X70 sqmm xlpe 235 Rmt
893 5.031 4c X35 sqmm xlpe 4200 Rmt
894 5.032 4C x 16sqmm xlpe 2480 Rmt
895 5.033 4C x 10sqmm xlpe 1890 Rmt
896 5.034 4C x 6sqmm xlpe 3420 Rmt
897 5.035 4C x 4sqmm xlpe 2340 Rmt
898 5.036 4C x 2.5sqmm xlpe 3330 Rmt
899 5.037 4c x 1.5sqmm 3060 Rmt
900 5.038 Screened cable 4c x 1.5sqmm 2100 Rmt
901 5.039 Supplying and Installation of cable end termination with Double brass compression gland and Copper lugs for the following sizes of PVC Insulated XLPE armoured conductor cable of 1.1KV grade complete as required..
902 5.04 1C x 240 sqmm xlpe 102 Nos
903 5.041 4C X70 sqmm xlpe 240 Nos
904 5.042 4c X35 sqmm xlpe 190 Nos
905 5.043 4C x 16sqmm xlpe 320 Nos
906 5.044 4C x 10sqmm xlpe 390 Nos
907 5.045 4c x 2.5sqmm 420 Nos
908 5.046 4c x1.5sqmm 20 Nos
909 5.047 Supplying and installation of Copper earth plate
910 5.048 25 x3 mm x 2 run 2800 Rmt
911 5.049 Supplying and installation of following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
912 5.05 600mm width x 100mm height x 3mm thickness 632 Rmt
913 5.051 450mm width x 100mm height x 3mm thickness 298 Rmt
914 5.052 300mm width x 100mm height x 3mm thickness 102 Rmt
915 5.053 225mm width x 100mm height x 3mm thickness 400 Rmt
916 5.054 150mm width x 100mm height x 3mm thickness 540 Rmt
917 5.055 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 180 Nos
918 5.056 Providing & fixing in position the mercury in glass industrial type thermometers. 180 Nos
919 5.057 Supplying and installation of 25mm Ball valves with flange end, pressure rating PN 16 with insulation and 24g AL cladding 103 Nos
920 5.058 Supplying and installation of Auto air vent size 25mm dia with 9 Rmt 20mm copper pipe. 125 Nos
921 5.059 Supplying,installation,testing and commissioning of Electromagnetic Descaler for Chilled water flow suitable capacity of 500 mm dia. 1 Nos
922 5.06 Supplying,installation,testing and commissioning of Centrifugal, Side Stream Filter for Chilled water, 500mm dia- 9600 gpm. 1 Nos
923 5.061 Supplying, installation and commissioning of trible duty valves for pumps, pressure rating of PN16 -with insulation and 24g AL cladding
924 5.062 450 mm dia 4 Nos
925 5.063 400 mm dia 3 Nos
926 5.064 250 mm dia 5 Nos
927 5.065 200 mm dia 13 Nos
928 5.066 Supply, installation and commissioning of following nominal sizes of chilled water piping (with necessary clamps, vibration isolators and fitting but excluding valves, stainers, gauges etc.)duly insulated with fire retardant quality expanded polystrene moulded pipe section of densidy 20kg/cu.m after a thick coat of cold setting adhestive (CPRX compound) wraping with 500g polythene fced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date)at joints repairing of damage to building etc. as per specifications and as required complete in all respect.\nNote :- The pipes of sizes 150mm & below shall be M.S 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from mnimum 6.35 mm thick M.S sheet for pipes upto 350mm dia. and minimum 7mm thick MS sheet for pipes of 400mm dia and above. 75mm Insulation for pipe above 150mm to 650mm and 50 mm for pipe\nbelow 150mm.
929 5.067 500mm dia 420 Rmt
930 5.068 450mm dia 90 Rmt
931 5.069 400mm dia 85 Rmt
932 5.07 300mm dia 90 Rmt
933 5.071 Supply,installation and commissioning of Butterfly value with C I body ss disc. Nitrille rubber seal & o-Ring PN 16 pressure rating for chilled water/hot heater circulation as specified.
934 5.072 500 mm dia 1 Nos
935 5.073 450 mm dia 1 Nos
936 5.074 400 mm dia 1 Nos
937 5.075 350 mm dia 2 Nos
938 5.076 Air Handling Units
939 5.077 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density, inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 57 TR- 30000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch,enclosed box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n 10 Nos
940 5.078 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density, inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 50 TR- 30000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal.\nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages.\nd) Charges for Air balancing works for the above with low side.\ne) charges for Water balancing for the above mentioned. \nf) Supplying and installation charges for fire rated canvas connection for the above.\n 3 Nos
941 5.079 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density, inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thich nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 50 TR- 25000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above 32 Nos
942 5.08 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 39 TR- 21000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s.Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n 2 Nos
943 5.081 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 30 TR- 16000CFM, 100mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n 8 Nos
944 5.082 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/Cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 30 TR- 14000CFM, 80mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n 5 Nos
945 5.083 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10micron pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above- Capacity of 20 TR- 10000CFM, 70mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and installation charges for fire rated canvas connection for the above\n 1 Nos
946 5.084 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commisoing filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above- Capacity of 20 TR- 9500CFM, 65mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconect switch encloser box and required BMS compatable for the above operation\nb) Supplying and instaltion of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and instaltion of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and instaltion charges for fire rated canvas conection for the above\n 2 Nos
947 5.085 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commisoing filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above- Capacity of 16 TR- 8000CFM, 65mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconect switch encloser box and required BMS compatable for the above operation\nb) Supplying and instaltion of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and instaltion of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and instaltion charges for fire rated canvas conection for the above\n 1 Nos
948 5.086 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commisoing filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above-Capacity of 16 TR- 7000CFM, 50mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconect switch encloser box and required BMS compatable for the above operation\nb) Supplying and instaltion of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and instaltion of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and instaltion charges for fire rated canvas conection for the above\n 2 Nos
949 5.087 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordgingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commisoing filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminium damper and outlet aluminium damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and saftey guard, view panel, required spring mounted vibration isolater for the above- Capacity of 12TR- 6500CFM, 50mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and instaltion for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconect switch encloser box and required BMS compatable for the above operation\nb) Supplying and instaltion of PCC pedestal 6Nos of 300X300X200mm H with 2 Nos of 12mm Thick Rubber pads for each pedestal \nc) Supplying and instaltion of Rigid MS supports with Enamel painting for valve packages\nd) Charges for Air balancing works for the above with low side \ne) charges for Water balancing for the above mentioned \nf) Supplying and instaltion charges for fire rated canvas conection for the above\n 1 Nos
950 5.088 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plenum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 6 TR- 2500CFM, 50mm total Static and fan outlet velocity shall be less than 9m/s.Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nc) Charges for Air balancing works for the above with low side \nd) charges for Water balancing for the above mentioned \ne) Supplying and installation charges for fire rated canvas connection for the above\n 2 Nos
951 5.089 Supply,installation, testing and commissioning of Double skin air handling unit with 48+-3mm thick puff 48 Kg/cum density , inner and outer skin shall be 0.64+-0.04mm thick,6 ROW deep coil having 13 FPI with coil face velocity 500 FPM, Filter face velocity 350 fpm(there should not be pressure drop at bag filter face area selection should be made accordingly for maximum efficiency),direct coupled high efficiency of Plug typ fan ,IE2 -TEFC Squirrel gauge induction motor,Commissioning filter ,10microm pre filter and 5micron back filter washable type, 900mm depth Return air plennum section with fresh air and return air aluminum damper and outlet aluminum damper , SS 304- 18G drain pan with 32mm thick nitrile insulation, limit switch and safety guard, view panel, required spring mounted vibration isolater for the above- Capacity of 4 TR- 2700CFM, 50mm total Static and fan outlet velocity shall be less than 9m/s. Each model AHU Should be tested as per AHRI 430 in third party test lab\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch encloser box and required BMS compatable for the above operation\nb) Supplying and installation of Rigid MS supports with Enamel painting for valve packages\nc) Charges for Air balancing works for the above with low side \nd) charges for Water balancing for the above mentioned \ne) Supplying and installation charges for fire rated canvas connection for the above\n 1 Nos
952 5.09 HEAT RECOVERY UNITS
953 5.091 Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick . Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, 450 mm depth enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 10300cfm@ external static 80mm and exhast air fan shall be 8755cfm, 76% of efficieny for sensibel and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides, Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch,enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhaust and Supply air fan suitable vfd and b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n\n 2 Nos
954 5.092 Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick . Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, with enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 8900cfm@ external static 80mm and exhast air fan shall be 7565cfm, 76% of efficieny for sensibel and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides.Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhast and Supply air fan suitable vfd b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n 8 Nos
955 5.093 Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick . Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, with enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 14700cfm@ external static 80mm and exhast air fan shall be 12495cfm, 76% of efficieny for sensibel and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides.Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhaust and Supplying air fan suitable vfd b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n 2 Nos
956 5.094 Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick. Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, with enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 4700cfm@ external static 80mm and exhast air fan shall be 3995cfm, 75% of efficieny for sensibel and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhaust and Supplying air fan suitable vfd b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n 1 Nos
957 5.095 Supply, installation, testing and commissioning of HEAT RECOVERY WHEEL UNIT with assembled condition all Sheet metal cabinet type double skin HRU, the inner and outer sheets of the double skin shall be 0.64 mm thick pre-coated and pre plasticized sheets with 50 mm thick . Backward aero foil curve fan, fan motor,fan casing insulation for acoustic, with enthalpy recovery, Filter section with Pre Filter, Bag Filter, Hepa filter ( Box type 450mm length ) & UVGI lamp on both sides, sound level shall be 60dbA from 1 mtr for both sides of air stream.Units shall be complete with opposed blade volume control dampers at both oulets, Duct flexible connector (fire proof) shall be provided at outlets.Limit switches for the doors with necessary cabling works for the proper function.Bulk head fitting including necessary electrical and control cabling for its proper operation, Fresh air temp DB:103F, WB: 82F, Exhaust air temp DB:76F, RH:60-66%, duct static pressure sensor (range 100-150pa). capacity of Supplying air fan 8200cfm@ external static 80mm and exhast air fan shall be 6970cfm, 75% of efficiency for sensible and latent heat, exhaust/fresh air side consist of EU3,EU9 , with Ultra violet germicidal irradiation Lamp on both sides Energy wheel velicity shall be less as per coil face velocity\na) Supplying and installation for Suitable IP21 VFD & PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, enclosed box and required BMS compatible for the above operation - panel shall have cubical type with exhaust and Supply air fan suitable vfd b) Single phase power rotor motor\nc) Charges for Air balancing works for the above with low side \nd) Supplying and installation charges for fire rated canvas connection for the above\n\n 1 Nos
958 5.096 Fan coil Units
959 5.097 1.5 TR Capacity - 850 CFM 25mm Static,complete with isolation valve,Strainer,modulation type valve with actuators, inclusive of 30mm thick nitrlie rubber insulation and 26g Al cladding and 22G SS drain tray with 25mm nipple provision for drain connection , 5 m copper 4 core flexible wire with flexible Gi house with plug top 1 Nos
960 5.098 2.0 TR Capacity - 900 CFM 25mm Static,complete with isolation valve, Stainer,modulation type valve with actuators, inclusive of 30mm thick nitrlie rubber insulation and 26g Al cladding and 22G SS drain tray with 25mm nipple provision for drain connection , 5 m copper 4 core flexible wire with flexible Gi house with plug top 1 Nos
961 5.099 2.5 TR Capacity - 1000CFM 25mm Static,complete with isolation valve, strainer, modulation type valve with actuators, inclusive of 30mm thick nitrlie rubber insulation and 26g Al cladding and 22G SS drain tray with 25mm nipple provision for drain connection , 5 m copper 4 core flexible wire with flexible Gi house with plug top 3 Nos
962 5.1 PIPING
963 5.101 Supply, installation and commissioning of following nominal sizes of chilled water piping (with necessary clamps, vibration isolators and fitting but excluding valves, stainers, gauges etc.)duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20kg/cum after thick coat of cold setting adhestive (CPRX compound) wraping with 500gauge polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date)at joints repairing of damage to building etc. as per specifications and as required complete in all respect.\nNote :- The pipes of sizes 150mm & below shall be M.S 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from mnimum 6.35 mm thick M.S sheet for pipes upto 350mm dia. and from minimum 7mm thick MS sheet for pipes of 400mm dia and above.\n75mm Insulation for pipe above 150mm to 650mm and 50 mm for pipe below 150mm.
964 5.102 350 mm dia 132 Rmt
965 5.103 300 mm dia 350 Rmt
966 5.104 250 mm dia 1356 Rmt
967 5.105 200 mm dia 456 Rmt
968 5.106 150 mm dia 672 Rmt
969 5.107 125 mm dia 154 Rmt
970 5.108 100 mm dia 940 Rmt
971 5.109 80 mm dia 360 Rmt
972 5.11 65 mm dia 106 Rmt
973 5.111 50 mm dia 150 Rmt
974 5.112 40 mm dia 30 Rmt
975 5.113 32 mm dia 120 Rmt
976 5.114 25 mm dia 312 Rmt
977 5.115 Supply and installation of ms Class C pipe with Insulated Condensate Drain pipe-25mm thick rigid puff density 48 Kg/m3, 24G AL. cladding
978 5.116 65 mm dia 820 Rmt
979 5.117 50 mm dia 900 Rmt
980 5.118 40 mm dia 740 Rmt
981 5.119 32 mm dia 390 Rmt
982 5.12 25 mm dia 170 Rmt
983 5.121 Balancing Valve with built in measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected outside pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
984 5.122 350 mm dia 2 Nos
985 5.123 300 mm dia 2 Nos
986 5.124 250 mm dia 2 Nos
987 5.125 200 mm dia 2 Nos
988 5.126 150 mm dia 2 Nos
989 5.127 125 mm dia 2 Nos
990 5.128 Supply, installation and commissioning of Butterfly Valve with extended stem of 100mm length, pressure rating of PN16, SS wafer/stem with insulation and 24g Al cladding
991 5.129 250 mm dia 6 Nos
992 5.13 200 mm dia 4 Nos
993 5.131 150 mm dia 6 Nos
994 5.132 125 mm dia 4 Nos
995 5.133 100 mm dia 70 Nos
996 5.134 80 mm dia 36 Nos
997 5.135 65 mm dia 12 Nos
998 5.136 50 mm dia 2 Nos
999 5.137 40 mm dia 6 Nos
1000 5.138 32 mm dia 4 Nos
1001 5.139 Supply, Installation, Testing and Commissioning of following sizes electronic, self balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 10V DC and 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.
1002 5.14 100 mm dia 35 Nos
1003 5.141 80 mm dia 18 Nos
1004 5.142 65 mm dia 6 Nos
1005 5.143 50 mm dia 1 Nos
1006 5.144 40 mm dia 1 Nos
1007 5.145 32 mm dia 12 Nos
1008 5.146 25 mm dia 3 Nos
1009 5.147 Supply,installation and commissioning of Ball valve with flange end, pressure rating of PN25-with insulation and 24G al cladding
1010 5.148 32 mm dia 40 Nos
1011 5.149 25 mm dia 50 Nos
1012 5.15 Supply,installation and commissioning of Ball valve with strainer flange end, pressure rating of PN25-with insulation and 24G al cladding
1013 5.151 32 mm dia 10 Nos
1014 5.152 25 mm dia 5 Nos
1015 5.153 Supply,installation and commissioning of Y Stainer of Ductile C I body ends with stainless steel strainer for chiller / hot water circulation including insulation as specified.
1016 5.154 100 mm dia 35 Nos
1017 5.155 80 mm dia 18 Nos
1018 5.156 65 mm dia 6 Nos
1019 5.157 50 mm dia 1 Nos
1020 5.158 40 mm dia 1 Nos
1021 5.159 32 mm dia 12 Nos
1022 5.16 25 mm dia 3 Nos
1023 5.161 Supply, installation and commissioning of BTU meter with ultrosonic type, required sensor, display unit ,pressure rating of PN16, SS wafer/stem with insulation and 24g AL cladding,suitable for 230v power
1024 5.162 100 mm dia 35 Nos
1025 5.163 80 mm dia 18 Nos
1026 5.164 65 mm dia 6 Nos
1027 5.165 50 mm dia 1 Nos
1028 5.166 40 mm dia 1 Nos
1029 5.167 32 mm dia 12 Nos
1030 5.168 25 mm dia 8 Nos
1031 5.169 Supply and installation of test point of size 25mm dia 134 Nos
1032 5.17 LOW SIDE WORKS
1033 5.171 Supply, installation,balancing and commissioning of factory fabricated(180GSM) GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,splitter damper, vanes,hangers, supports etc. as per approved drawings and specifications of following complete as required.
1034 5.172 18G (1.25mm) 11895 Sqmt
1035 5.173 20G (1.00mm) 1423 Sqmt
1036 5.174 22G (0.80mm) 11002 Sqmt
1037 5.175 24G (0.63mm) 25783 Sqmt
1038 5.176 Supply & fixing of powder coated extruded aluminium Supply air grilles 459 Sqmt
1039 5.177 Supply and installation of Drum type diffuser with collar control damper with heavy duty type aluminium anodized profile materials. 257 Sqmt
1040 5.178 Supply and installation of al.powdered coated round diffusers with damper (450 to 600 ext dia) 149 Nos
1041 5.179 Supply, installation, testing and commisioning of GI voulme control damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, 459 Sqmt
1042 5.18 Supply and installation of (S/R )adjustable vane Swril type diffuser size 600mm x 600 mm, Handling of air volume of 600cfm to 650cfm 80 Nos
1043 5.181 Supply, fixing,testing and commissioning of the dampers in suply air duct / main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorised and spring return so as to close the damper in the event of power failure auromatically and open the same in case of power being restrored. the spring return action shall be inbuilt machanism and not externally mounted.The damper shall alos be closed in the event of fire signal complete as required and as per specification. 87 Sqmt
1044 5.182 Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications.
1045 5.183 300 mm dia 210 Sqmt
1046 5.184 250 mm dia 179 Sqmt
1047 5.185 200/150/100 mm dia 193 Sqmt
1048 5.186 Supply and installation of Plenum boxes 24G with inside 6mm thick nitrile rubber insulation (525x525x450 mm) 212 Nos
1049 5.187 Supply and installation of Butterfly dampers dia 300 mm 210 Nos
1050 5.188 Supply and installation of Butterfly dampers dia 250 mm 179 Nos
1051 5.189 Supply and installation of Butterfly dampers dia 100/150/200 mm 193 Nos
1052 5.19 Supply and installation of toilet exhast disc valves (size 100 to 150mm ) with control damper 1457 Nos
1053 5.191 Supply and fixing of following thickness duly laminated aluminium foil of mat finish closed cell nitrille rubber (class "O")insulation on existing duct after applyinh suitable adhesive for nitrille rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrille rubber tape insulation complete as per specifications and as required.
1054 5.192 25mm 26986 Sqmt
1055 5.193 19mm 14425 Sqmt
1056 5.194 Supply, installation and commissioning of Duct Accoustic (Nitrile rubber base, Open cell material 25mm thick, Thermal conductivity 0.047w/m.k@20deg C, excellent absorption, 99.9% reduction of bacterial growth, class1 fire performance, with a density of 140-180Kg/cubicmeter) 4047 Sqmt
1057 5.195 Supply and installation of Non return air dampers low leakage type with spring loaded 22 Sqmt
1058 5.196 Supply, installation of gripple hanger system for ducts instalation -hanging weight 60 -120kg 5315 Nos
1059 5.197 Supply and installation of drain pump (1.5m lift of water)with motor for FCUs and CSUs, required 5Rmt cable between motor and isolater with 5amps plu top 5 Nos
1060 5.198 Supply, installation, testing and commissioning of Double skin plennum section of 50mm thick puff 48 kg/cum density , inner and outer skin shall be 0.64mm thick with required GI Base , inner shall be 25mm thick armosound accoustic insulation to be attached suitable suitable 370 Sqmt
1061 5.199 VENTILATION WORKS
1062 5.2 Supply, installation, testing and commissioning of Double skin cabinet type liftwell pressurization ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 50000cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n 2 Nos
1063 5.201 Supply, installation, testing and commissioning of Double skin cabinet type liftwell pressurization ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 42500 cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n 4 Nos
1064 5.202 Supply, installation, testing and commissioning of Double skin cabinet type liftwell/Stair pressurization ,inner skin and outer skin shallbe 0.64 mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 23500cfm-36 mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n\n 2 Nos
1065 5.203 Supply, installation, testing and commissioning of Double skin cabinet type liftwell pressurization ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 19000cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n\n 1 Nos
1066 5.204 Supply, installation, testing and commissioning of Double skin cabinet type Fresh /exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 16150cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n\n 1 Nos
1067 5.205 Supply, installation, testing and commissioning of Double skin cabinet type Fresh air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 11500cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\ne) Supply and installation of outdoor type Rigid mounted canopy for the above\n 14 Nos
1068 5.206 Supply, installation, testing and commissioning of Double skin cabinet type fresh/exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter , limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 6200cfm-36mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above\n\n 8 Nos
1069 5.207 Supply, installation, testing and commissioning of Double skin cabinet type Fresh air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 5800cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 5 Nos
1070 5.208 Supply, installation, testing and commissioning of Double skin cabinet type exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 5300cfm-30mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 8 Nos
1071 5.209 Supply, installation, testing and commissioning of Double skin cabinet type Fresh air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 4900cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 5 Nos
1072 5.21 Supply, installation, testing and commissioning of SISW exhast air fan,Aerofoil backward curve fan with high eff. motor of IE2 type,outlet damper needs to be provoided, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 50000cfm-105mm total static \na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 1 Nos
1073 5.211 Supply, installation, testing and commissioning of Double skin cabinet type Fresh/exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 4700cfm-30mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 7 Nos
1074 5.212 Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 4300cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 24 Nos
1075 5.213 Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 3600cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 12 Nos
1076 5.214 Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 2800cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 3 Nos
1077 5.215 Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 2500cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 5 Nos
1078 5.216 Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 2200cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 6 Nos
1079 5.217 Supply, installation, testing and commissioning of Single skin cabinet type Fresh/exhast air fan , skin shallbe 1.6mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, inlet section having 900mm wide plenum section with 10micron filter, limit swicth and view glass and etc, cabin shall be outdoor type - Capacity of 1500cfm-25mm total static\na) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch, suitable type indoor panel and required BMS compatable for the above operation\nb) Supply and installation of PCC pedestal 300X300X200mm H with 2 Nos of 12mm thick Rubber pads for the each fan Supports\nc) Charges for Air balancing works for the above with low side \nd) Supply and installation charges for fire rated canvas connection for the above 3 Nos
1080 5.218 Supply, installation, testing and commissioning of Inline fans, The casing shall be single skin 0.64mm thick, internally acoustically lined and constructed of galvanized steel sheet. The fan shall be forward curve impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 3 phase 50 cycles AC Supplying. Low sound level exceeding Nost more than 39 dBA at three meter distance. All necessary standard accessories like flexible connectors,vibration isolaters etc.- 1000 cfm -25mm of total static\na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above 10 Nos
1081 5.219 Supply, installation, testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 1200cfm-25mm total static \na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above 2 Nos
1082 5.22 Supply, installation, testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 1000cfm-25mm total static \na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above 8 Lot
1083 5.221 Supply, installation, testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 800cfm-25mm total static\na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above 1 Lot
1084 5.222 Supply, installation,testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe 0.64mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 300cfm-25mm total static\na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above 1 Lot
1085 5.223 Supply, installation, testing and commissioning of cabinet type single skin cabinet exhast air fan ,inner skin and outer skin shallbe .8mm thick,Aerofoil backward curve fan with high eff. motor of IE2 type,inlet and outlet damper needs to be provoided, - Capacity of 76000cfm-50mm total static\na) Supply and installation for disconnect switch, suitable type indoor panel \nb) Charges for Air balancing works for the above with low side \nc) Supply and installation charges for fire rated canvas connection for the above 7 Lot
1086 5.224 CAR PARK/FUME EXTRACT VENTILATION SYSTEM
1087 5.225 System shall be based on current NBC standards and meet the requirements of local Fire Authority \nSupply and installation of Exhaust air Vane axial fan 17000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination, \na) Supply and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supply and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supply and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supply and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper, GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supply and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supply and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supply and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supply and installation for Emergency Push button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing\n\n 14 Nos
1088 5.226 Supply and installation of Exhaust air Vane axial fan 34000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination,\na) Supply and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supply and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supply and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supply and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper , GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supply and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supply and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supply and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supply and installation for Emergency Push button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing \n\n 36 Nos
1089 5.227 Supply and installation of Exhaust air Vane axial fan 32000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination, \na) Supplying and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supplying and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supplying and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supplying and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper , GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supplying and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supplying and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supplying and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supplying and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supplying and installation for Emergency Pusb button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing \n\n 2 Nos
1090 5.228 Supply and installation of Exhaust air Vane axial fan 27000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination, \na) Supply and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supply and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supply and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supply and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper, GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supply and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supply and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supply and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supply and installation for Emergency Push button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing \n\n 3 Nos
1091 5.229 Supply and installation of Exhaust air Vane axial fan 90000CFM @ 25 mm wg Static Pressure, Fan with Single Speed Motor Rating shall be 960 to 1450 RPM, DB level shall be less than 65 db. at 1.5m distance for both the side , Rigid Mounting frame for ceiling/floor and required terminal box with suitable rating and suitable for cable termination, \na) Supply and installation of Axial Fan Silencer for both fresh air exhaust air - Silencer having round diameter as per the suitable selection of fan diameter and outer casing thickness shall be 1.2mm thick 120GSM Gi Sheet, 150mm thick fiber glass with the density of 48kg/cum, required RP tissue and 20G Al Perforated sheet for the above suitable size fan dia , Silencer length shall be minimum of 1200mm\nb) Supply and installation of Bird / Wire Mesh 16 G.I Material it has suitable for the above fan selection and it should be removable type, \nc) Supply and installation of Sleeve type (600mm depth) Fire damper with suitable Fire rated activator it should be UL 555 Rated\nd) Supply and installation for GI Round to square Duct for mouth connection for the above silencer to Fire damper, GI duct length shall be minimum of 1.5meter, Duct flange shall be Hot dipped Ms. angle Iron for the both the side of the ducts\ne) Supply and installation for Suitable Vibration mounting for the selection of fans for 4Nos/fan\nf) Supply and installation for Suitable IP55 VFD with PID controller (A0-2.Ai-4,DO-5,DI -5) with disconnect switch and encloser box and required BMS compatible for the above operation\ng) Supply and installation of Fire rated canvas for duct connection for the above, Fire rating range shall be 300deg C 2hr rating\nh) Supply and installation for Hot dip gal vanished MS channel Fabrication for Fan erection, fan may erection ceiling hanging or floor mounting type , support height shall be minimum of 2m, Required anchor faster included\ni) Supply and installation for Emergency Push button station for the above , Fire rated type\nj) CO/CO2 detector head (Analog sensor-Should match the specifications),0- 250 ppm, with necessary arrangement of suitable fixing \n 6 Nos
1092 5.23 Supply and fixing of following 25mm sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 8320 Rmt
1093 5.231 Supply and installation of Push button station for emergency stop 192 Nos
1094 5.232 Supplying and installation of Exhaust Air Grilles/Louvers with flange shall be 40mm wide heavy duty type 191 Sqmt
1095 6 FIRE FIGHTING WORKS PUMP HOUSE
1096 6.001 Supplying, Installation, Testing and Commissioning of 171 Cum/hr. TEFC type electrically driven horizontal centrifugal (End Suction type) Main pumpset with class F insulation & IP 55 protection for Fire Hydrant & Sprinkler system at 100 Mtrs. Head and 2900 rpm with all necessary accessories like providing and fixing bronze impeller, stainless steel shaft coupling, coupling guard, mechanical seal, Cast Iron pump casing & baseplate for pump, fabricated mild steel channel with foundation bolts, etc Pump shall have electrical motor of adequate H.P. suitable for electric Supplying of 415V, 50 Hz, 3Ph Star/Delta Starter connection. 2 Sets
1097 6.002 Supplying, Installation, Testing and Commissioning of 171Cum/hr. diesel engine driven horizontal centrifugal pumpset (End Suction type) Standby pumpset for Fire Hydrant & Sprinkler system at 100 Mtrs. Head & 1800/2100 rpm with all necessary accessories like providing & fixing bronze impeller, stainless steel shaft, Direct coupling, Mechanical seal, Cast Iron pump casing, base plate for pump, fabricated mild steel channel with foundation bolts etc., It includes providing & fixing fuel 200 litres elevated tank with Supplying and return piping, steel supports for diesel tank, valves, fill and vent lines, flexible connections, 2 sets of battery with charging arrangement, alternator & instrument panel suitable for 24 volt DC including starting switches to be connected to control panel of diesel engine and exhaust silencer including necessary pipework and lagging, etc., Batteries, cooling water line for engine with required pipes, valves, fittings, exhaust fittings, etc., 1 Set
1098 6.003 Supplying, Installation, Testing and Commissioning of 10.8 Cum/hr. TEFC type Vertical In line pump Jockey pumpset with class F inulation & IP 55 protection for Fire Hydrant & Sprinkler system at 100 Mtrs. Head and 2900 rpm with all necessary accessories like providing and fixing SS304 impeller & stage casing, stainless steel shaft, Mechanical seal, coupling guard & CI base for pump, fabricated mild steel channel with foundation bolts, etc. Pump shall have electrical motor of adequate H.P. suitable for electric Supplying of 415V, 50 Hz, 3Ph for DOL Starter connection. 2 Set
1099 6.004 Supplying, Installation, Testing and Commissioning of C.I. body, EPDM seat, SGI disc, Butterfly valve PN 16, SGI Hand lever operated, wafer ends conforming to BS:5155.
1100 6.005 300 mm NB. 2 Nos.
1101 6.006 200 mm NB. 6 Nos.
1102 6.007 150 mm NB. 6 Nos.
1103 6.008 80 mm NB. 6 Nos.
1104 6.009 Supplying, Installation, Testing and Commissioning of Flanged Ball type Non return Valve PN 16, SGI body & reinforced rubber coat ball, conforming to IS 5312, Vertical installation.
1105 6.01 300 mm NB 1 Nos.
1106 6.011 200 mm NB. 4 Nos.
1107 6.012 80 mm NB 1 Nos.
1108 6.013 Supplying, Installation, Testing and Commissioning of gunmetal gate valve having screwed ends as per specification with necessary flanges, nut, bolts & washers, etc. complete as required conforming to IS 778.
1109 6.014 32 mm NB Gate valve 4 Nos.
1110 6.015 25 mm NB Gate valve 64 Nos.
1111 6.016 Supplying, Installation, Testing and Commissioning of C.I body & cover, SS304 strainer & carbon steel bolts & nuts. - Pot type Strainer.
1112 6.017 300 mm NB. 1 Nos.
1113 6.018 250 mm NB. 3 Nos.
1114 6.019 100 mm NB. 1 Nos.
1115 6.02 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
1116 6.021 300 mm NB Pipes. 27 RMT
1117 6.022 200 mm NB Pipes. 57 RMT
1118 6.023 80 mm NB Pipes. 46 RMT
1119 6.024 25 mm NB Pipes. 52 RMT
1120 6.025 Supplying, Installation, Testing and Commissioning of Dial type pressure guage with 150mm dial and a range of 0-10 Kg./sq.cm. together with siphon and pet cock. 6 Nos.
1121 6.026 Supplying, Installation, Testing and Commissioning of pressure switches together with accessories. 4 Nos.
1122 6.027 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 1 Set.
1123 6.028 Supplying, Installation, Testing and Commissioning of Sheet steel fabricated cubicle type, MCC with Star-Delta starter IP55 panel for the electrical motor driven pumpset, DOL starter for Jockey pumpset complete with isolator switch, voltmeter, ammeter manual / auto mode switch, indicating lamps etc., Potential free contacts pumps, for third party integeration for Fire alarm system, BMS, etc., for identifying the on/off status, trip status for all pumps and lube oil level status for diesel driven pump. \nIncomer shall be with mechanical interlock with 2 lock & 1 Key \nINCOMING : 2 Nos, 400A 4 Pole 35KA MCCB, 400A TP&N copper Busbars with colour coded heat shrinkable PVC sleeves. 1 Set of RYB indicating lamps with individual HRC control fuses. 1 Nos. 96 sq.mm, 0-630 Amps, Ammeter with selector switch and suitable rated current transformers. 1 Nos. 0-400 96sq.mm, Voltmeter with selector switch.\nOUTGOING : Feeder for main pumps - 2nos. 250 A TP&N 35KA MCCB and Star & Delta Starter with overload relay, single phase preventor and indicating lamps with ON/OFF push buttons. \nFeeder for Jokey Pump - 2nos. 1 No 63A 25 KA TP&N MCCB without releases DOL starterwith over load relay, single phase preventor and indicating lamps with ON/OFF push buttons, 1 No . Automanual selector switch. \n1no Dummy provision. and 1no 16A TP MCCB for battery charger and control panel.\n\n\n 1 Set
1124 6.029 Supplying, Installation, Testing and Commissioning of PVC insulated, XLPE, aluminium conductor, 1.1 KV grade armoured, MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970
1125 6.03 3 1/2 X 95 sqmm 90 Mtr.
1126 6.031 4C X 16 sqmm 24 Mtr.
1127 6.032 12 C X 2.5 sqmm copper aromoured cable for Diesel engines. 48 Mtr.
1128 6.033 2 C X 2.5 sqmm copper aromoured cable for instrumentation 90 Mtr.
1129 6.034 Supplying, Installation, Testing and Commissioning of cable end termination with brass compression gland and Aluminium lugs for the following sizes of PVC Insulated XLPE Aluminium armoured conductor cable of 1.1KV grade complete as required..
1130 6.035 3 1/2 X 95 sqmm 8 Set
1131 6.036 4C X 16 sqmm 2 Set
1132 6.037 12 C X 2.5 sqmm copper aromoured cable for Diesel engines. 2 Set
1133 6.038 2 C X 2.5 sqmm copper aromoured cable for instrumentation 20 Set
1134 6.039 Providing and fixing 25 mm x 3 mm copper strip on surface or in recess for connections etc. as required. 45 Mtr.
1135 6.04 Providing and fixing following sizes of copper wire on surface or in recess for connections etc. as required.
1136 6.041 8 SWG Copper 45 Mtr.
1137 6.042 Supplying, Installation, Testing and Commissioning of perforated G.I.sheet cable tray with neccessory angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size of the tray shall be as mentioned below for laying the above mentioned cables.
1138 6.043 600mm 30 Mtr.
1139 6.044 300mm 30 Mtr.
1140 6.045 150mm 30 Mtr.
1141 6.046 Supplying, Installation, Testing and Commissioning of diesel pump exhaust, 100mm Dia MS pipe with residential type silencer, mineral wool thermal insulation and 24G aluminium cladding, with necessary supports, clamps, bolts, nuts, etc., 45 Mtr.
1142 6.047 Supplying and Erection Structural Supports like MS Angle / Channel / 'U' clamps, etc., 750 Kgs.
1143 6.048 GRAND TOTAL
1144 6.049 HYDRANT & SPRINKLAR
1145 6.05 Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
1146 6.051 200 mm NB 1355 RMT
1147 6.052 80 mm NB 50 RMT
1148 6.053 Work will include painting for the above ground piping with one coat of primer and two coat of enamel paint of approved colour. Work will include cleaning of pipe, degreasing, necessary supports, clamps, bolts, nuts,etc. Headers shall be worded indicating the direction of the pipe and its purpose.
1149 6.054 200 mm NB 1070 RMT
1150 6.055 150 mm NB 337 RMT
1151 6.056 100 mm NB 36 RMT
1152 6.057 80 mm NB 184 RMT
1153 6.058 Supplying, Installation, Testing and Commissioning of C.I. body, EPDM seat, SGI disc, Butterfly valve PN 16, SGI Hand lever operated, wafer ends conforming to BS:5155.
1154 6.059 200 mm NB. 5 Nos.
1155 6.06 150 mm NB. 16 Nos.
1156 6.061 100 mm NB. 33 Nos.
1157 6.062 Supplying and installation of RCC Hume pipes of 600 mm dia with collars for road / below floor crossing of Fire water pipes as per IS 458. The rate shall includes excavation, soil levelling for bed and ends shall be closed with Brick masonry work as directed by site engineer. 180 RMT
1158 6.063 Supplying, Installation, Testing and Commissioning of Air Release Valve with Ball Valve - 25 mm dia to all wet risers all complete. 32 Nos.
1159 6.064 Supplying, Installation, Testing and Commissioning of Internal hydrants including landing valve stations hose reels, etc., comprising of the following.
1160 6.065 63mm dia Twin outlet landing valve as per IS : 5290 together with cap and chain. 48 Nos.
1161 6.066 Hose reel drum assembly with swinging and rolling arrangement together with 19mm dia x 45.0 mtrs. long hose, cnc machined Single rod IS standard Bright Material with Special “O” rings & Grooved Nozzle. and 6.25mm nozzle durable Nylon material, Jet spray & shut by hand revolving., 19mm NB ball valve at tap-off etc., as per IS : 884. 48 Nos.
1162 6.067 2 nos - 65 mm dia R.R.L Hose of 15 Mtrs. Length, together with heavy GM couplings combined with 2 nos nozzle & branch pipe as per IS2871. 48 Nos.
1163 6.068 Supplying, Erection, Testing and Commissioning of MS hose cabinet stand mounted type, fabricated out of M.S sheet of 16 swg, with glass fronted (4mm thick glass with rubber beeding) door and size of the cabinet shall be 900mm x1200 mm x 250 mm, Qouted rate shall be includes suitable stand for mounting as fastners etc., and cabinet shall be powder coated of approved colour both inside and outside. 48 Nos.
1164 6.069 Supplying, Installation, Testing and Commissioning of External standpost type Yard hydrants comprising of the following.
1165 6.07 63mm dia Single hydrant valve as per IS : 5290 together with cap and chain. 33 Nos.
1166 6.071 2 nos - 65 mm dia R.R.L Hose of 15 Mtrs. Length, together with heavy GM couplings combined with 1 nos nozzle & branch pipe. 33 Nos.
1167 6.072 Supplying, Installation, Testing and Commissioning of MS hose cabinet stand mounted type, fabricated out of M.S sheet of 16 swg, with glass fronted (4mm thick glass with rubber beeding) door and size of the cabinet shall be 600mm x750 mm x 250 mm, Qouted rate shall be includes suitable stand for mounting as fastners etc., and cabinet shall be powder coated of approved colour both inside and outside. 33 Nos.
1168 6.073 Supplying, Installation, Testing and Commissioning of Fire brigade inlet siamese connection (4way) manifold in including valves and check valve of size 150mm size along with 4 nos. 63mm dia instantaneous inlet arrangements to the main header with cap and chain etc., for external hydrants. 1 No.
1169 6.074 Supplying, Installation, Testing and Commissioning of Fire brigade inlet siamese connection (4way) manifold in including valves and check valve of size 150mm size along with 4 nos. 63mm dia instantaneous inlet arrangements to the main header with cap and chain etc., for fire sump. 1 No.
1170 6.075 Construction of Valve Pits Size of 1000 x 1000 mm outer dimension and to be required. internal dimension as under, upto 1.5 Mtr depth with brick masonry in cement mortor 1:5, with thickness of masonry 225mm, 1:3:6 cement concrete foundation 150mm thick over 150mm sand bed, channelling in 1:2:4 cement concrete, plastering in 1:3 cement mortor for internal and external surface & finished with floating coat of neat cement. Fixing of 600*600 including precasting D.I. manhole heavy duty grade C-250,weight of cover must be 90kg theft proof cover and frame including painting of the frame & cover .The work shall include all necessary excavation and back filling. 38 Nos.
1171 6.076 SPRINKLER SYSTEM
1172 6.077 Supplying, Installation, Testing and Commissioning of FM approved & UL listed Control Valve consisting of - 1 no. Alarm valve(Clapper check type, Vertical mount), 1 no. Main stop valve, 1 no. water motor with alarm gong (light weight non metallic material), with strainer, Pressure guage drain valve and proper drain piping etc., as per specification.
1173 6.078 i) 200 mm dia. 1 Set
1174 6.079 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
1175 6.08 200 mm NB 1070 RMT
1176 6.081 150 mm NB 1338 RMT
1177 6.082 100 mm NB 628 RMT
1178 6.083 80 mm NB 1415 RMT
1179 6.084 65 mm NB 1813 RMT
1180 6.085 50 mm NB 2916 RMT
1181 6.086 40 mm NB 5454 RMT
1182 6.087 32 mm NB 2246 RMT
1183 6.088 25 mm NB 10962 RMT
1184 6.089 Supplying, Installation, Testing and Commissioning of C.I. Butterfly valve PN 16 Hand lever operated, wafer ends conforming to BS:5155.
1185 6.09 200 mm NB 4 Nos.
1186 6.091 150 mm NB 52 Nos.
1187 6.092 100 mm NB. 6 Nos.
1188 6.093 80 mm NB. 44 Nos.
1189 6.094 Supplying, installation, testing and commissioning of FM approved make vane type flow switches (flow sensors) suitable to be fixed directly on line of the following diameters, with 1 NO & 1 NC potential free contacts (suitable provision for IBMS system)
1190 6.095 150mm dia 44 Nos.
1191 6.096 100mm dia
1192 6.097 Supplying, Installation, Testing and Commissioning of chromium finish, 15mm size Upright / Pendent type sprinkler suitable to operate at 68/79 deg.C temperature(K=80). 7727 No
1193 6.098 Supplying, Installation, Testing and Commissioning of chromium finish, 15mm size side wall type sprinkler suitable to operate at 68/79 deg.C temperature(K=80).
1194 6.099 Supplying, Installation, Testing and Commissioning of braided SS 304 flexi hose dropper 1.2mtr length with standard support accessories, neat finish, withstand system test and working pressure. 2051 No
1195 6.1 Supplying, Installation, Testing and Commissioning of Rosette plates for sprinklers at False ceiling level. 2051 Nos.
1196 6.101 Supplying and Erection Structural Supports like MS Angle / Channels, etc., for Pump room. 2750 Kgs.
1197 6.102 Supplying and installation of hot dip GI puddle flanges, as per IS-1239, fabricated out of 6mm MS Plate, fixed at the RCC walls of the fire tanks & Over head tanks, work includes paiting with 2 coats of primer complete as required, refer tender dwgs for details.
1198 6.103 300mm Dia GI flange 1 Nos
1199 6.104 250mm Dia GI flange 3 Nos
1200 6.105 200mm Dia GI flange
1201 6.106 150mm Dia GI flange 2 Nos
1202 6.107 100mm Dia GI flange 8 Nos
1203 6.108 80mm Dia GI flange 24 Nos
1204 6.109 Liasoning work for Obtaining Local Fire Authority NOC/Approvals for complete systyem & miscellaneous work etc. 1 Lot
1205 6.11 EXTINGUISHER
1206 6.111 Supplying and fixing of Minimax or approved equivalent make 4.5kg CO2 Type Fire Extinguisher with fire rating 21B. Design, construction and testing as per IS 15683, supplied with Body bearing IS 7285 mark, operating temperature -30°C to +55°C, external double PU paint coating with PO shade No 538 of IS 5, Packing 7ply thick corrugated, co2 purity IS 15222, Valve IS 3224, supplied with standard accessories. 129 Nos
1207 6.112 Supplying and fixing of Minimax or approved equivalent make 6kg DCP Powder type fire extinguisher, IS 15683 Gas cartridge type with fire rating 21B. Design, construction and testing as per IS 15683, Body hydro tested at 35bar, operating temperature -30°C to +55°C, external epoxy powder coating with PO shade No 538 of IS 5, supplied with standard accessories. Supplied with ISI marked gas cartridge as per IS 4947 and DCP (Sodium Bicarbonate base as per IS 4308) Cylinder must be subjected to Anti-corrosive treatment of 7 tank process. 218 Nos
1208 6.113 Supplying and fixing of Minimax or approved equivalent make HFC236fa Instaprotect (modular type), 10kg ceiling mounted fire extinguisher. Body hydro tested at 35bar, operating temperature -30°C to +55°C, external epoxy powder coating with PO shade No 538 of IS 5, supplied with standard accessories.Charged pressure 8kg/cm2. Cylinder must be subjected to Anti-corrosive treatment of 7 tank process. a. Firespot-Room Protection system-Clean Agent-HFC236fa- Modular-10 kg with solenoid valve,2 nos smoke detector ,fire alarm panel,Gunnebo control unit(SMS alert for Leak alarm), Hooter. a. Firespot-Room Protection system-Clean Agent-HFC236fa- Modular-10 kg with solenoid valve,2 nos smoke detector, fire alarm panel, Gunnebo or approved equalent make control unit(SMS alert for Leak alarm),Hooter.(FOR IBMS ROOM) 1 Set
1209 7 PROVIDING LIFT WORKS
1210 7.001 PASSENGER LIFT:- (MAIN BUILDING) Design, Supplying, Erection, Testing and commissioning of Machine room less Passenger lift with Stainless Steel finish to carry 24 passengers of 1632 Kgs as per following details\nSpeed = 1.25 Mtr / Sec; Travel Distance = 12 Mtrs, Number of Floors = G + 1, Positing of Machinery = Machine Roomless, Design of Lift Car = Stainless steel Hailine Finish, Car Ceiling - Car Floor = Sleek (small circular lights) - SS hairline finish -pvc, Type Of Car Front Entrance Protection - Power operated centre opening sliding door - stainless steel -, Land Entrance Protection (0,1 ) - Centre Opening Sliding door - Stainless Steel - Hairline Finish, Landing Door Frame (0,1 ) - Stainless steel - Hairline Finish, Type Of Control System - Microprocessor based Quadraplex Selective Collective control With / Without attendant, Special Inclusion, Battery Operated Emergency Light And Alarm Bell, Call Register Signal And Vf Door Operator, Landing Push Button In Landing Door Frames, Automatic Rescue Device, Stainless Steel Button With S.S. Cover, Full Car Operating Panel, Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour, Floor Annunciator With Music, Firemans Switch, False Ceiling In Car, Fire Rating Of Landing Doors - Two Hours, Infra Red Door Screen, Overload Warning Indicator, Scaffolding, 3 Way Intercom / Press And Speak Phone, Free Service For One Year, Pit Ladder, Ss Handrail, Lift License\nThe rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift.\nNote: Tenderer should be given options for car Interiors. The final Approval given by Client/ Engineering Consultant \nNote: Control of Operation ( Simplex /Duplex ) should follow as per Technical Specification 4 Nos
1211 7.002 GOODS LIFT:- ( MAIN BUILDING ) Design, Supplying, Erection, Testing and commissioning of Machine room less Service lift with Pre Coated Steel Grey and Blue finish to carry 2000 Kgs as per following details\nSpeed = 1.00 Mtr / Sec, Travel Distance = 24 Mtrs, Number of Floors = G + 3, Positing of Machinery = Machine Roomless, Design of Lift Car = Pre-Coated steel (Grey & Blue), Car Ceiling - Car Floor = standard - standard -m.s. cheq. plate flooring, Car Fittings - Indirect LED Tubelight & Regular (Circular) - Fan\nType Of Car Front Entrance Protection - Power Operated Centre Opening 4 panel sliding door - Precoated Steel - Blue, Type Of Control System - Microprocessor Based Simplex selective collective control With / Without attendent, Special Inclusion, Battery Operated Emergency Light And Alarm Bell\nCall Register Signal And Vf Door Operator, Landing Push Button In Landing Door Frames, Automatic Rescue Device, Full Car Operating Panel, Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour, Floor Annunciator, Firemans Switch, Fire Rating Of Landing Doors - Two Hours, Infra Red Door Screen, Overload Warning Indicator, Scaffolding, Pit Ladder\nThe rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift. 6 Nos
1212 7.003 ESCALATOR:- Design, Supplying, Erection, Testing and commissioning of 1000mm width Commercial Type Escalator with 0.50Mtr/Sec as per the following details Standards - EN 115, Horizontal steps - 3 Nos, Vertical Rise - 6000mm, Horizontal Span - 15951mm, Inclination - 30 degree, Gear Box - Worm Gear, Intermediate support - 1 No, Handrail Colour - Black, Balustrade Profile - Hairline Stainless steel, Balustrade Panel - 10mm thick Tempered safety Glass, Balustrade Height - 1000mm, Step - Die Cast aluminium Grey Colour with Yellow Demarcation, Combs - Die cast Aluminium, Led Traffic Light - Fixed Arrow Sign - One Each at Top & Bottom, Outside Tuss Cladding - Hairline Stainless steel on Left, Right & Bottom, Auto Start - Diffuse / Radar Sensor Type The rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift. 4 Nos
1213 7.004 PASSENGER LIFT:- ( MULTILEVEL CARPARKING ) Design, Supplying, Erection, Testing and commissioning of Machine room less Passenger lift with Stainless Steel finish to carry 16 passengers of \n1088 Kgs; Speed = 1.25 Mtr / Sec, Travel Distance = 24 Mtrs, Number of Floors = G + 6, Positing of Machinery = Machine Roomless, Design of Lift Car = Pre-Coated steel (Grey & Blue), Car Ceiling - Car Floor = standard - standard -m.s. cheq. plate flooring, Car Fittings - LED Lights & Cross Flow fan, Type Of Car Front Entrance Protection - Power Operated Centre Opening 4 panel sliding door - Precoated Steel - Blue, Type Of Control System - Microprocessor Based Simplex selective collective control With / Without attendent, Special Inclusion, Battery Operated Emergency Light And Alarm Bell\nCall Register Signal And Vf Door Operator, Landing Push Button In Landing Door Frames, Automatic Rescue Device, Stainless Steel Button With S.S. Cover, Full Car Operating Panel, Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour, Floor Annunciator With Music, Firemans Switch, False Ceiling In Car, Fire Rating Of Landing Doors - Two Hours, Infra Red Door Screen, Overload Warning Indicator, Scaffolding, 3 Way Intercom / Press And Speak Phone, Pit Ladder, Ss Handrail\nThe rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift. 4 Nos
1214 8 BUILDING MANAGEMENT SYSTEM - ACMV
1215 8.001 CENTRAL WORK STATION SYSTEM
1216 8.002 Supplying, Installation, Testing & Commissioning of Intel core i7 processors with min 3.4 Ghz or later configuration, 8 GB RAM expandable to 16 GB, 512 KB Pipeline burst cache, 256 Flash ROM, Can be upgraded from a diskette, 3 PCI Slots, 4 ISA slots (3 slot shared), On-board Graphics, PCI-e card with at least 1280 x, 1024 res., 1TB, 350 W switchable/50 Hz Power Supplying, 104 keys window 98 keyboard, PS/2 Compatible, wireless, RAID 5configuration, Raid 5 with Hot swap Spare, Min 4 USB and 2 nos. of 100 Mbit/s Ethernet port, Windows 8.1 professional, Office, Current Java Runtime environment, .NET Framework 1.1, 2.0, 3.51, EPA compliant Power Manager, Integrated / external speaker with audio card, Based on SNMP protocol Desk Manager, PC-Cilin or equivalent pre-loaded Anti Virus Software (minimum for 2 years), PAQ 95 or equivalent pre-loaded Diagnostic Software, 100 Mbps Network Interface Card with wake on LAN support, Built in 16X DVD Writer, 24” LED Monitor SVGA 1024 X 768 min. Resolution with A4 Size Laser Jet colour Printer. 2 Set
1217 8.003 SOFTWARE & NETWORK CONTROLLER - 8000 IO POINTS
1218 8.004 Supplying, Installation, Testing & Commissioning of BMS System Software : Graphical Software meeting the requirements in the Given I/O Summary and technical specifications including configuration and facility to create / provide the graphic mapping for all I/O Summary points , animate the Graphics, Navigation between pages, display of logs, changing the time zones, pop up alarms, configurable password protection for Building Management System as per Specifications. Software shall be able to communicate with Lon works, Bacnet, Mod bus devices simultaneously, open protocol, with unlimited point capacity 1 Nos
1219 8.005 Supplying, Installation, Testing & Commissioning of Interface Network controller (Router) Supplying , installing, testing and commissioning of Network Supervisory Controller unit for connecting all controllers to it and transferring data to PC platform.& Soft Integration with HVAC equipments and all other 3rd party equipments 1 Lot
1220 8.006 Supplying, Installation, Testing & Commissioning of Network Controller Access: Multiple Operator Access with Max support for User Access Level with passwords with various configuration privileges for monitoring and control of DDC Controllers - using with Open protocol(for integeration controllers) All Integeration controllers should be enclosed in Rittal Panels with Proper power Supplying and Connections
1221 8.007 Chiller plant manager integration - 240 points 1 Lot
1222 8.008 Chiller pump panel integeration - 200 points 1 Lot
1223 8.009 Energy meters - 150 Points 1 Lot
1224 8.01 LIFT integration - 200 points 1 Lot
1225 8.011 DG Integration - 200 points 1 Lot
1226 8.012 FAS Integration - 1500 points 1 Lot
1227 8.013 VFD Integration - 2000 points 1 Lot
1228 8.014 Solar Panel Integration - 250 points 1 Lot
1229 8.015 STP Integration - 200 points 1 Lot
1230 8.016 UPS Integration - 200 points 1 Lot
1231 8.017 Portable operator terminal kit for stand alone programming. 1 Set
1232 8.018 DDC CONTROLLERS
1233 8.019 Supplying, Installation, Testing & Commissioning of Automation stations / DDC Controller with I/O module etc., The controllers shall be microprocessor based standalone and net workable type with real time clock and historical database of min 1 MB. The DDC's shall be capable of peer to peer communication without help of system interface controller or PC. with locable mounting cabinets duly powder coated connector strip, internal wiring and space to house controller & relays, connector strip current transformer, MCB, internal wiring. (Contractor shall confirm his I/O provision w.r.t requirement on basis of data point) on BACnet /IP. Ref IO Summary
1234 8.02 DDC Controller with Rittal enclosures for Chiller , Pumps etc 1 nos
1235 8.021 DDC Controller with Rittal Enclosures for Tank Levels 2 nos Rain Water Tank 1 nos
1236 8.022 DDC Controller with Rittal Enclosures for Tank Levels Raw Water Tank -2 nos. 2. Treated Water Tank -2nos 3. Fire Tank Water - 1no, 4. RO Tank - 1 no. 1 nos
1237 8.023 DDC for HSD Tank 1 nos
1238 8.024 DDC for Ventilation Fans (132 Fans, 12 Carpark Ventilation) 1 LOT
1239 8.025 Supplying, Installation, Testing & Commissioning of below Field Devices
1240 8.026 Outside Air Temperature , RH Sensor & CO2 sensor 1 nos
1241 8.027 Immersion Temp Sensor - 200 mm Length 16 nos
1242 8.028 Duct Temp Sensor 180 nos
1243 8.029 Water Level Switch including with High & Low Level 11 nos
1244 8.03 Flame proof Level Switch with High & Low Level 2 nos
1245 8.031 BTU meter - 250 mm dia 3 nos
1246 8.032 Supplying, Installation, Testing & Commissioning of below cables, conduits & trays
1247 8.033 Signal cable for analog input & outputs : 2 Core X 1.5 mm PVC sheathed shilded copper unarmored cable. 15000 Rmt
1248 8.034 Signal cable for digital input & outputs : 4 Core X 1.0 mm PVC sheathed unshilded copper unarmored cable 10000 Rmt
1249 8.035 25mm dia PVC Conduit with Accessories 15000 Rmt
1250 8.036 25mm dia GI Conduit with Accessories 3500 Rmt
1251 8.037 Supplying and Erection of perforated 300mm cable tray with cover, neccesary supports, bolts, nuts, etc 500 Rmt
1252 8.038 FIRE ALARM SYSTEM
1253 8.039 Supplying, Installation, Testing, and Commissioning of Intelligent Addressable Panel. The Panel should have LCD Display with a minimum 640 Characters, Battery supervision, flash EPROM memory, walk test, 4 operator access levels, 1000 historical event log, zone and individual selectable settings and programme features. The panel should be configured for 48 hours normal working conditions and operate for a minimum of 2Hrs during emergency. The Panel should have all features and functions mandated by NFA, BIS. The Panel should be configured for a minimum of 3000 devices with additional capacity to spare 10% devices. The panel should be supplied inclusive of Battery, Programming Interface board, Communication Board, Programming Software, Monitoring Software, and requisite number of loop cards. Each loop card should be able to connect atleast 159 devices. The panel should be UL or FM Listed. The panel shall be in single enclosure panel with expandable provisions. The panel shoul suppport Bacnet Over IP, for BMS integeration.
1254 8.04 10 Loop panel with 5 Loop Cards 1 Set
1255 8.041 Supplying, Installation, Testing, and Commissioning of Passive Repeater Panel with LCD Display, 640 Characters for monitoring the Fire Alarm System. The display should provide events and messages as displayed on the main fire alarm system panel. Should be UL or FM Listed. 1 Set
1256 8.042 Supplying, Installation, Testing, and Commissioning of Addressable Heat Detector with Rate of Rise detection of 15 degree F to 20 degree F per minute, and detect Fixed Temperature of 100 degree F. The detector will have LED indicatoors with 360 degree view with indetifiable indications for fault, normal, communication, emergency operation modes. Should be supplied with Base & Junction Box complete with all accessories. Should be UL or FM Listed. 50 Nos
1257 8.043 Supplying, Installation, Testing, and Commissioning of Addressable Multi Sensor Detector with Optical Smoke detection, Rate of Rise detection of 15 degree F to 20 degree F per minute, and detect Fixed Temperature of 100 degree F. The detector will have LED indicatoors with 360 degree view with indetifiable indications for fault, normal, communication, emergency operation modes. Should be supplied with Base & Junction Box complete with all accessories. Should be UL or FM Listed. Below Ceiling 539 Nos
1258 8.044 Supplying, Installation, Testing, and Commissioning of Addressable Multi Sensor Detector with Optical Smoke detection, Rate of Rise detection of 15 degree F to 20 degree F per minute, and detect Fixed Temperature of 100 degree F. The detector will have LED indicatoors with 360 degree view with indetifiable indications for fault, normal, communication, emergency operation modes. Should be supplied with Base. Should be UL or FM Listed. Above Ceiling 172 Nos
1259 8.045 Supplying, Installation, Testing, and Commissioning of Response/Remote Indicators 172 Nos
1260 8.046 Supplying, Installation, Testing, and Commissioning of Addressable Beam Detector. Should be a UL or EN approved device capable of electronically addressable, compensation ageing, capable of alerting slow accumulation of dust particles after a threshhold level. Should be effective for optical distances of 8 to 100 meters. Should be supplied along with Reciever. with Zone control 26 Nos
1261 8.047 Supplying, Installation, Testing, and Commissioning of Addressable Manual Calling Point. Manual Calling point should be loop powered type and resettable with lock & Key. Manual Calling Point should be of hard ABS plastic or metal construction colored in RED with instructions to operate clearly like "Press Here". Should be supplied with suitable back Boxes and bases. The Manual Calling Point should be mounted at 1.4m, easily reachable and convenient location as marked in the drawings. Should be UL or FM Listed. 97 Nos
1262 8.048 Supplying, Installation, Testing, and Commissioning of Addressable Loop operated combined sounder and strobe. The Sounder should be programmable for controlling the sound level like 65dB, 75dB, 85dB etc. Sounder Tone and Strobe blink rate should be programmable. The Sounder with Strobe should be loop powered, and mounted at 2.1m height. Should be UL or FM Listed. 86 Nos
1263 8.049 Supplying, Installation, Testing, and Commissioning of Addressable Isolators. Should isolate the affected loop portion in case of fault or shortcircuit. Should be able to reste once the fault is removed. Should be capable of monitoring upto 30 or more devices. Should be UL or FM Certified. Should be supplied with base. 39 Nos
1264 8.05 Supplying, Installation, Testing, and Commissioning of Addressable Monitor Module. Should be able interface non addressable devices and communicate with the panel. Should be UL or FM certified. 74 Nos
1265 8.051 Supplying, Installation, Testing, and Commissioning of Addressable Control Relay module, Tripping of Third Party Equipment, MS Powder coated Junction Box for mouting on Surface. The CR will be connected to Deactivating AHUs, Lifts & activating the Public Address system, Control Relay Modules in suitable ABS Plastic glossy Box. 136 Nos
1266 8.052 Supplying and laying, connecting & commissioning of 2C x 1.5 sq.mm, Armoured Stranded Copper conductor, FRLS Cable 650 V as per IS 1554. 13990 Rmt
1267 8.053 25mm dia GI Conduit with Accessories 4500 Rmt
1268 8.054 GI perforated tray of 300mm width with 1.5mm thickness 500 Rmt
1269 8.055 PUBLIC ADDRESS MANAGEMENT SYSTEM
1270 8.056 Supplying, Installation, Testing and commissioning of 20 Zone Call Station, Stem Type Microphone, 2 mm thick CRCA Sheet Powder Coated Rack, Dual Tone Control for Speech & Music, integration facility with Fire Alarm System, tone generator & Speech Processor with relays for activating tone & per-recorded fire alarm messages, facility to integrate with the base builder P.A System as specified in the Tender Specifications . The rate inclusive of Priority module, selector switch etc. 1 Nos
1271 8.057 Supplying, Installation, Testing and Commissioning of Rack Mounted minimum 480 W mixer Amplifier 9 Set
1272 8.058 Supplying, Installation, Testing and Commissioning of Rack Mounted minimum 240 W mixer Amplifier 6 Nos
1273 8.059 Supplying, Installation, Testing and Commissioning of Rack Mounted minimum 120 W mixer Amplifier 1 Nos
1274 8.06 Supplying, Installation, Testing and Commissioning Voice Alarm Controller with router 1 Set
1275 8.061 Supplying, Installation, Testing and commissioning of Wireless Mic 1 Set
1276 8.062 Supplying, Installation, Testing and commissioning of Gooseneck Mic 1 Nos
1277 8.063 Supplying, Installation, Testing and commissioning of auto dialer for Fire Alarm System. 1 Nos
1278 8.064 Supplyinging, installing, testing and commissioning of 1 No. each of AM/FM Tuner with World space receiver , DVD player with overriding facility, Music Source Selector, with assignable priority on each channel to accept Music, Telephone, Microphone, Recorded message from Voice recorder etc., with in-built compressor and limiter. - License for World space receiver also need to be included for 6 years 1 Set
1279 8.065 Speakers
1280 8.066 Supplying, Installation, Testing and commissioning of 6 Watt Wall Mounted Metal Speakers with line matching transformers & selectable tap setting 136 Nos
1281 8.067 Supplying, Installation, Testing and commissioning of 15 Watt Wall Mounted Metal Speakers with line matching transformers & selectable tap setting 176 Nos
1282 8.068 Supplying, Installation, Testing and commissioning of 30 Watt Wall Mounted Metal Speakers with line matching transformers & selectable tap setting 53 Nos
1283 8.069 Cabling and Accessories
1284 8.07 Supplying, Installation, Testing and commissioning of 19", 48 U Floor mount Rack to mount the Amplifiers. 2 Set
1285 8.071 Supplying and laying of 2 Core 1.5 Sq.mm Armoured unshielded Cable 8278 Rmt
1286 8.072 25mm dia GI Conduit with Accessories 3400 Rmt
1287 8.073 CCTV SYSTEM
1288 8.074 Supplying, Installation, Testing and commissioning of Workstation: Supplying, Installation, Testing and commissioning of IBM PC compatible system minimum of i5, 8GB RAM, 1TB Hard Disk, Optical Reader/Writer Drive, Wired Keyboard, Display with 2 or more PCI Expansion Slots, 2 or more USB 2.0 or later ports, 1 RS232 or RS485 port, Windows 7 Professional or later, Antivirus Software with Licenses. 2 Set
1289 8.075 Supplying, Installation, Testing and commissioning of LED Monitors, 40” 1,920 x 1,080 (16:9) 2 Nos
1290 8.076 Supplying, Installation, Testing and commissioning of NVR, Embedded System with LCD Display, 2GB or more memory, Support Raid 0, 1, 5, Multiple Ethernet ports with aggregate/trunk multiple ports capabilities. Should support minimum bandwidth of 192Mbps. Should be capable of Recording 64Ch @1080p and storage capacity of storing for 15 days of 64Cameras@1080p, 30fps. 5 Nos
1291 8.077 Supplying, Installation, Testing and commissioning of Surveillance Grade 6Gbps, 3.5" Hard disks, 4TB, 7200rpm 40 Nos
1292 8.078 Supplying, Installation, Testing and commissioning of IP 2MP Dome Cameras, IR Range 20m Supplying, Installation, Testing and commissioning of IP IR Dome Cameras, 1/2.7” Image Sensor, 3.6mm 1080P(1920×1080) @25FPS, with Dual Stream H.264 Main Profile and MJPEG. Should support PoE Power (802.af Type 1). Should support Smart Detection, DWDR, Day/Night (ICR), 3DNR, AWB, AGC, BLC features. 0.01Lux/F2.0 (Color), 0Lux/F2.0(IR on). IR Range should be 30m or more. Camera should be IP65 rated or more. 79 Nos
1293 8.079 Supplying, Installation, Testing and commissioning of IP 2MP Bullet Cameras, IR Range 50m Supplying, Installation, Testing and commissioning of IP IR Dome Cameras, 1/2.7” Image Sensor, 3.6mm 1080P(1920×1080) @25FPS, with Dual Stream H.264 Main Profile and MJPEG. Should support PoE Power (802.af Type 1). Should support Smart Detection, DWDR, Day/Night (ICR), 3DNR, AWB, AGC, BLC features. 0.01Lux/F2.0 (Color), 0Lux/F2.0(IR on). IR Range should be 30m or more. Camera should be IP65 rated or more. 37 Nos
1294 8.08 Supplying, Installation, Testing and commissioning of IP 2MP Bullet Camera, IR Range 30m Supplying, Installation, Testing and commissioning of IP IR Bullet Cameras, 1/2.7” Image Sensor, 3.6mm 1080P(1920×1080) @25FPS, with Dual Stream H.264 Main Profile and MJPEG. Should support PoE Power (802.af Type 1). Should support Smart Detection, DWDR, Day/Night (ICR), 3DNR, AWB, AGC, BLC features. 0.01Lux/F2.0 (Color), 0Lux/F2.0(IR on). IR Range should be 30m or more. Camera should be IP65 rated or more. 73 Nos
1295 8.081 Supplying, Installation, Testing and commissioning of PTZ cameras 5 Nos
1296 8.082 L3 Manageable Gigabit Switches Supplying, Installation, Testing and commissioning of L2/L3 Manageable switches with VLAN, QoS, Stackable, and Rack Mountable, 24 Ports. Switch should be capable of switching 55+ Gbps and forwarding 40+ Million packets/second. Should have separate Uplink ports and Stacking ports. Should have VLAN, QOS Features. Should support 4K VLANS. Should support Link Aggregation, STP, Port Grouping. Should have Web and CLI based Management interface and support RADIUS, SNMP, MIBs (Standard and Private). Switch should have minimum 24 Ports PoE. Should be supplied inclusive of Patch Panels. 23 Nos
1297 8.083 Supplying, Installation, Testing and commissioning of Network Racks, 6U, Floor Mount Supplying, Installation, Testing and commissioning of 6U Network Rack inclusive of Mounting Accessories, Cable Manager, Fixtures, 1x24 Port Patch Panels. 30 Set
1298 8.084 Supplying, Installation, Testing and commissioning of Network Racks, 42U, Floor Mount Supplying, Installation, Testing and commissioning 42U Network Rack Accessories, Fixtures, Power Managers, Ventilation Fans, Cable Managers and Organizers, Castor Wheels. Side and Back Doors should be removable with Front side door. 2 Set
1299 8.085 Supplying, Installation, Testing and commissioning of Gigabit Media Converters or SFP Modules inclusive of LJU, Splicing, Patch Cables, Pigtails 60 Set
1300 8.086 Supplying, laying, Testing and commissioning of CAT6 cable from Network Switches to End Devices (Cameras, Access Controllers) 10539 Rmt
1301 8.087 Supplying, laying, Testing and commissioning of Cabling of 6 Cores, Armored SM Optical Fiber Optic Cable from Switches, to CMS Room 990 Rmt
1302 8.088 Supplying, laying, Testing and commissioning of 25mm PVC Conduit with necessary accessories 7500 Rmt
1303 8.089 Supplying, laying, Testing and commissioning of 25mm GI Conduit with necessary accessories 3900 Rmt
1304 8.09 Supplying and Erection of perforated 300mm G.I.cable tray with cover, neccesary supports, bolts, nuts, etc 400 Rmt
1305 8.091 Supplying and Erection of perforated 450mm G.I cable tray with cover, neccesary supports, bolts, nuts, etc 300 Rmt
1306 8.092 ACCESS CONTROL SYSTEM - Access & Attendance Management System
1307 8.093 Access Management Workstation: Supplying, Installation, Testing, and commissiong of IBM PC compatible system minimum of i5, 8GB RAM, 1TB Hard Disk, Optical Reader/Writer Drive with 21” or more LED Display Panel, Wired Keyboard, Display with 2 or more PCI Expansion Slots, 2 or more USB 2.0 or later ports, 1 RS232 or RS485 port, Windows 7 Professional or later, Antivirus Software with Licenses. 1 Nos
1308 8.094 Network Management Controller: Supplying, Installation, Testing, and commissiong of Network Management Controller with Access Management Software, requisite Software User License for 1000 users, 65000 Door Access Controllers. Should support 255 Door Access Controllers, work in Independant and Network Modes. Aux In, and Out forts for integration with Fire Alarm System. Controller should support 25,000 Users and 500,000 Events log or more. 1 Set
1309 8.095 Biomteric Attendance System: Supplying, Installation, Testing, and commissiong of Biomteric Attendance System with Finger Print Recognition, Support for 1:1, and 1:N recognitions modes. Should be able to work offline and online. Should have capacity to store 3000 fingerprints or more, and 50,000 log transactions. Software should have user security and Dialy, Weekly, Monthly attendance reports with facility to export data. Software should be user friendly, and work on Windows 7 or later systems 3 Nos
1310 8.096 Door Access Controller: Supplying, Installation, Testing, and commissiong of of Door Access Controller with built-in Mifare Contactless Card Reader, 50,000 Events Storage, EM Lock interface, Exit Reader interface, Exit Switch i/p. Should be able to communicate over RS-485 or Network Interfaces. Should be rated for IP65, and have visual led indicators. Should draw power from PoE port, Accept cards conforming to ISO 7810 ID1 size, and ISO/IEC14443. Optionally it may have 12v DC input. Supplying should be inclusive of Backboxes and Accessories 10 Nos
1311 8.097 Exit Readers: Supplying, Installation, Testing, and commissiong of Mifare Contactless Readers. Should accept cards conforming to ISO 7810 ID1 size, and ISO/IEC14443 mifare standards. Should IP65 rated, visula led indicators. Power should be drawn from Door Access Controller and may have 12v DC input. Should have RS232/RS485/Wiegand or suitable interface to communicate with Door Access Controller. Supplying should be inclusive of Backboxes and Accessories 10 Nos
1312 8.098 Emergency Door Release Switch (Glass Break type) Supplying, Installation, Testing, and commissiong of Glass break type Emergency Door Release Switch. Material may be plastic, color Green. Should be able to work minimum 3A at 36V DC or 50V AC. Should be clearly marked with ‘Emergency Exit Release’, ‘Break Glass’ and ‘Press to Exit’ or similar. 10 Nos
1313 8.099 Exit Switches Supplying and Installation of SS Exit Switches with back boxes. Should be clearly marked with ‘Press to Exit’ or ‘Exit Switch’ or suitable. Supplying should be inclusive of Backboxes. Should be able to handle 3A, 230vAC, Contact to have SPST with push to latch and release, mechanical life of 50000 cycles. 10 Nos
1314 8.1 Door Locks, Single Leaf Supplying, Installation, Testing, and commissiong of Single EM Lock with built-in Magnetic Contacts, Door Open signal. Should work with either 12v or 24v power Supplying and a holding force not less than 600Lbs. Should be supplied with suitable L, Z, U Brackets. 7 Nos
1315 8.101 Door Locks, Double Leaf Supplying, Installation, Testing, and commissiong of Double EM Lock with built-in Magnetic Contacts, Door Open signal. Should work with either 12v or 24v power Supplying and a holding force not less than 2x600Lbs Should be supplied with suitable L, Z, U Brackets. 3 Nos
1316 8.102 Mifare Contactless Cards: Supplying and Printing of cards conforming to ISO 7810 ID1 size, and ISO/IEC14443. 1200 Nos
1317 8.103 Supplying and Cabling of CAT6 from Network Switches to Door Controllers 1700 Rmt
1318 8.104 Supplying and Laying of 25mm PVC Conduit with necessary accessories 350 Rmt
1319 8.105 25mm dia GI Conduit with Accessories 2500 Rmt
1320 8.106 Supplying and Cabling of Un-Armored 4 Core 1.0sqmm from EM Lock to Door Access Controllers 350 Rmt
1321 8.107 Supplying and Laying of 20mm PVC Conduit with necessary accessories 350 Rmt
1322 8.108 Supplying and Cabling of Un-Armored 2 Core 1.0sqmm from Door Access Controller to Exit Switch / Emergency Release Switch 350 Rmt
1323 8.109 Supplying and Laying of 20mm PVC Conduit with necessary accessories 350 Rmt
1324 9 SEWAGE TREATMENT PLANT\nSupplying, installation, Testing and Commissioning of 250KLD Capacity SBR ( Sequence Batch Reactor) including all equipment / machinaries with following components & process:-\n( Process - Airlift arrangement and functional mechanisms, technology from Germany 4 Charging / 4 Discharge / 4 Sludge Transfer )\n1. Fine Bar Screen made up of SS 304 with 6mm spacing. Size L=800mm; W=1000mm = 1 No;\n2. Controller with Panel board ( Class IP 55/65 ) for the enclosure of controller and necessary electrical equipment’s (phase failure relay, MPCB, Contactors) = 1 No; \n3. Air Compressor of approved Germany make 340 cum / Hr ( Capacity 12.5HP operating Pressure @ 0.8 bar with 3phase Supply ) = 2 Nos; \n4. EPDM Fine bubble tubular diffusers 90 mm Dia,1m Long with SOTE>10.5% / m = 42 Nos;\n5. Diffusion system in SS 304 ( 6 outputs ) stands = 14 Nos;\n6. Hose, PVC braided from Polyhose at 10 kg / sqcm at temperature rating of 115 deg. C = 200Mtr;\n7. Clamps and fittings for wall mounting in SS 304 = 150Nos;\n8. Solenoid valves for airlift arrangement (Aira / Equivalent) (1.5”-2”) = 8 Nos;\n9. Submersible Monobloc Pump with 16 Cum / Hr Flow = 2 Nos \n10. MS Vessel with Multiport Valve 1200 mm dia, 1800mm height HOS Vessel Filter Media Sand, carbon and Supporting Media = 1 No;\n 1 LOT
1325 9.001 COMPRESSOR SYSTEM
1326 9.002 Supplying, Installation, testing and commissioning of Kaeser or equivalent make, Oil Flooded, Twin Rotary, Positive displacement, SCREW AIR COMPRESSOR, Motor Driven, With all necessary accessories, with built in Star Delta Starter, with neccessary integeration between both the drives, antivibration pads, Fittings having the following specifications, 55 KW, having FAD of 356 CFM at 7 bar working pressure and it shall be max of 8.5bar pressure. The scope Supplying includes Siemens IE3 premium efficeincy, Sq.Cage Induction Motor, TEFC type, suitable for operation on 400 V± 10%, 3 Phase, 50 Hz, AC Supplying, and for ambient temperature 45deg F Class insulation conforming to IS 1271, & drain arrangements. Scope of work includes cabling end terminations. The compressor controller shall be secured and RFID accessible and recovery of data shall be made possible with inbuilt SD card to track the data and history of equipment., The system should be IBMS compatiable. Performance adherence of equipment shall be made with respect to ISO 1217:2009, Annexure C. The capacity must be not less than the cited above. The scope of work includes neccessary cabling apprx 15rmts, glands, termination works between the control panel and the compressor. 2 Nos
1327 9.003 Installation, testing and commissioning of Kaeser or approved equivalent make, REFRIGERATED TYPE AIR DRYER, auto ON & OFF type and high COP of scroll compressor shall be placed inside With all necessary accessories, antivibration pads, Fitting & auto drain arrangement, having the following specifications, pressure dew point 3 deg, & having dryer capacity FAD of 1200 CFM with respect to design conditions, max. operating pressure 16KG/Cm2, 100% power consumption within 2.75KW with 10% tolerance, pressure drop shall be lies within 0.15 bar. The dryer shall be sized to handle max ambient temperature 40 deg C, max inlet temperature 45 deg C, Refrigerant 134A, 415V, 50Hz, 3Ph, Noise Level - less than 70 dBA. Scope of work includes, isolator, end terminations, electrical cabling between dryer and isolator apprx 15rmt. It shall contain fluorinated greenhouse gases covered by Kyoto protocol. The system should be IBMS compatiable. The capacity must be not less than the cited above. The scope of work includes neccessary cabling apprx 15rmts, glands, termination works between the control panel and the compressor. 1 Nos
1328 9.004 Installation, testing and commissioning of Kaesser or approved equivalent make Pre filter which ensures compressed air quality and remove particles equivalent to 1 µm meter. It shall be sized to handle both mentioned compressor capacities. 2 Nos
1329 9.005 Installation, testing and commissioning of Kaesser or approved equivalent make Pre filter which ensures compressed air quality and remove particles equivalent to 0.1 µm meter. It shall be sized to handle both mentioned compressor capacities. 2 Nos
1330 9.006 Installation, testing and commissioning of receiver, working temperature 60deg C, maximum working pressure 11 Kg/cm2, all internal surfaces shall be cleaned and one coat of black bituminous paint applied. Scopoe of work includes necessary,auto condensate drain - PRESSURE LOSS Electronic Condensate Drain Valve, it shall be splash proof and works on the principle of float based as accumulated condensates can be discharged very safely without single loss of compressed air and without intervention of maneuvres), mouting bolts nuts, flanges, drain arrangement Safety valve, Syphon Pipe, Pressure Gauge & Drain Valve. - 5 Cu.M 1 Nos
1331 9.007 Supplying, Installation, testing and commissioning of Overground PPR pipes -PN16 conforming to IS 15801 with All necessary fittings, such has couplers, elblows, reducers, tees, FTAs, MTAs,flanges, Unions, etc., including, clamping, bolts, nuts, angles, supports, etc.
1332 9.008 80 ID 51 Rmt
1333 9.009 65 ID 1126 Rmt
1334 9.01 36 ID 478 Rmt
1335 9.011 23 ID 67 Rmt
1336 9.012 Supplying of Leader/Audco make or equivalent approved make of C.I. body, EPDM seat, SS disc, Butterfly valve PN 16, SGI Hand lever operated, wafer ends conforming to BS:5155. The scope of work includes requried flanges to connect the pipes, etc.,
1337 9.013 80 NB (threaded connection type) 2 Nos
1338 9.014 65 NB (threaded connection type) 2 Nos
1339 9.015 50 NB (threaded connection type) 2 Nos
1340 9.016 Supplying of Leader/Audco make or equivalent approved make of Brass Ball valve PN25 with lever operated chromium plated brass ball suitable for threaded end connection.
1341 9.017 40 NB (threaded connection type) 30 Nos
1342 9.018 25 NB (threaded connection type) 12 Nos
1343 9.019 Supplying and construction MS Structure Work including Angels, 'C'- Channels, I- Beams with primer & painting etc. in compressor room. 450 Kgs
1344 9.02 Supplying and installation of double Earthing Strip for motor body earth, scope of work includes running the earthing strip / wire from the body to main earth strips.
1345 9.021 GI flat 50mmx6mm 50 Rmt
1346 9.022 10SWG copper wire 50 Rmt
Disclaimer :