Kannur International Airport Limited has published Construction Of Airport Police Station Construction Of Airport Police Station Including Internal And External Electrical Installations , Plumbing , Cctv , Internal And External Finishing And Allied Works For Kannur International Airport Ltd . . Submission Date for this Tender is 28-11-2019. Building Work Tenders in Kannur International Airport Ltd Kerala. Bidders can get complete Tender details and download the document.
Name of Work:Construction of Airport Police Station including Internal and External Electrical installations, Plumbing, CCTV, Internal and External finishing and allied works for Kannur International Airport Limited | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | (CIVIL WORKS)\nEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.\n\n All kinds of soil \n | BI01010001010000000000000515BI0100001113 | 40 | cum |
2 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | BI01010001010000000000000515BI0100001114 | 20 | cum |
3 | 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | BI01010001010000000000000515BI0100001115 | 120 | cum |
4 | 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level\n\n : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001116 | 12 | cum |
5 | 5 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).\n\nAll works upto plinth level \n | BI01010001010000000000000515BI0100001118 | 59 | cum |
6 | 6 | All works above plinth level upto floor V level | BI01010001010000000000000515BI0100001119 | 104 | cum |
7 | 7 | Providing & constructing Laterite masonry in CM 1 :6 with neatly dressed laterite stones of standard / approved size & approved quality (average compressive strength not less than 35 kg /Cm 2 ) including scaffolding ,raking out of joints ,curing,cost & conveyance of all material ,labour lead ,lift etc complete for all type of masonry works upto plinth level and in superstructure above the highest plinth level upto floor five level as directed by engineer in charge | BI01010001010000000000000515BI0100001120 | 240 | cum |
8 | 8 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete \n Thermo-Mechanically Treated bars of grade Fe-500D or more. | BI01010001010000000000000515BI0100001121 | 22170 | kg |
9 | 9 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :\n Foundations, footings, bases of columns, etc. for mass concrete\n | BI01010001010000000000000515BI0100001122 | 55 | sqm |
10 | 10 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :\nSuspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001123 | 580 | sqm |
11 | 11 | Centering and shuttering including strutting, propping etc. and removal of form for all heights \nLintels, beams, plinth beams, girders, bressumers and cantilevers | BI01010001010000000000000515BI0100001124 | 250 | sqm |
12 | 12 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :\nColumns, Pillars, Piers, Abutments, Posts and Struts | BI01010001010000000000000515BI0100001125 | 10.08 | sqm |
13 | 13 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :\n Stairs, (excluding landings) except spiral-staircases | BI01010001010000000000000515BI0100001126 | 15 | sqm |
14 | 14 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid with cement based high polymer modified quick-set tile adhesive grouting the joints with epoxy grout and matching pigments etc., complete.\n Size of Tile 600x600 mm | BI01010001010000000000000515BI0100001127 | 490 | sqm |
15 | 15 | CEMENT PLASTER (IN FINE SAND) \n 12 mm cement plaster of mix \n 1:6 (1 cement: 6 fine sand) | BI01010001010000000000000515BI0100001128 | 2250 | sqm |
16 | 16 | 6 MM CEMENT PLASTER\n 6 mm cement plaster of mix :\n 1:3 (1 cement : 3 fine sand) | BI01010001010000000000000515BI0100001129 | 540 | sqm |
17 | 17 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. | BI01010001010000000000000515BI0100001130 | 1900 | sqm |
18 | 18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | BI01010001010000000000000515BI0100001131 | 450 | sqm |
19 | 19 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :\n Two or more coats on new work | BI01010001010000000000000515BI0100001132 | 1900 | sqm |
20 | 20 | Finishing walls with Acrylic Smooth exterior paint of required shade :\n New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | BI01010001010000000000000515BI0100001133 | 920 | sqm |
21 | 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :\n For fixed portion\n Powder coated aluminium (minimum thickness of powder coating 50 micron) | BI01010001010000000000000515BI0100001134 | 75 | kg |
22 | 22 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) | BI01010001010000000000000515BI0100001135 | 120 | kg |
23 | 23 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):\n With float glass panes of 4.0 mm thickness | BI01010001010000000000000515BI0100001136 | 70 | sqm |
24 | 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :\nTwo or more coats on new work | BI01010001010000000000000515BI0100001137 | 30 | sqm |
25 | 25 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.\nFixed to steel windows by welding | BI01010001010000000000000515BI0100001138 | 420 | kg |
26 | 26 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin-Charge. \n 60mm thick Cement concrete paver block of M-35 grade\nwith approved colour, design & pattern. | BI01010001010000000000000515BI0100001139 | 1000 | sqm |
27 | 27 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting\nto size and shape wherever required.\n 1.00 mm thick with zinc coating not less than 275 gm/m² | BI01010001010000000000000515BI0100001141 | 140 | sqm |
28 | 28 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001142 | 3700 | kg |
29 | 29 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.\n 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001143 | 6 | cum |
30 | 30 | Providing and fixing stainless steel ( Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). | BI01010001010000000000000515BI0100001144 | 30 | kg |
31 | 31 | Providing and applying elastomeric flexible two component acrylic modified cementitious waterproof coating Masterseal 551 EL/Brushbond RFX or equivalent confirming( BS 1881 Part 208: 1996 I.S.A.T and DIN 1048 Water Penetration Test), for wet areas in two coats@2Kg Per M2 to achieve 1mm thickness. Concrete surfaces should be free of dust, oil and other contaminants. All high spots should be removed. Moss and lichen must be removed physically. After treatment wash down thoroughly with clean water and allow to dry. Prewetting the surface before applying the water proofing material. Apply first coat and after complete drying apply the second coat to be applied on the opposite direction. The material shall be applied as per manufacturers data sheet. The rate shall includes, cost and conveyance of all materials, labour charges, lead, lift, coving at all right angles, bore packing etc.cleaning and clearing the debris from all levels and disposing etc complete as per technical specification and as directed by the Engineer-in-Charge at all levels. The above work shall be carried out by an agency (authorised applicator of manufacturer) having sufficient experience in concerned work and should ensure a guarantee for any defective installation, material composition and water tightness for a period of 10 years from the date of completion of the said work. Only skilled and experienced persons shall be employed for this purpose. | BI01010001010000000000000515BI0100001145 | 380 | sqm |
32 | 32 | Providing and fixing Ist quality ceramic glazed wall tiles of thickness 8mm conforming to IS: 15622 , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over plastered surface and jointing cement based high polymer modified quick-set tile adhesive grouting the joints with epoxy grout and matching pigments etc., complete. | BI01010001010000000000000515BI0100001146 | 75 | sqm |
33 | 33 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge.\n Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side | BI01010001010000000000000515BI0100001148 | 22 | sqm |
34 | 34 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL\nanti-termite treatment (excluding the cost of chemical emulsion) :\nTreatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:\n With Chlorpyriphos/Lindane E.C. 20% with 1% concentration | BI01010001010000000000000515BI0100001150 | 307 | sqm |
35 | 35 | Providing and fixing 100mm brass locks (best make of approved quality)for Aluminium doors including necessary cutting and making good etc.complete. | BI01010001010000000000000515BI0100001151 | 27 | Each |
36 | 36 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete | BI01010001010000000000000515BI0100001152 | 52 | Each |
37 | 37 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. | BI01010001010000000000000515BI0100001153 | 28 | Each |
38 | 38 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10mm | BI01010001010000000000000515BI0100001154 | 27 | Each |
39 | 39 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) | BI01010001010000000000000515BI0100001155 | 105 | sqm |
40 | 40 | Granular Sub-Base - Grading-I - (Table:- 400-1) for lower sub base - Mix in Place Method\nConstruction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. | BI01010001010000000000000515BI0100001156 | 150 | cum |
41 | 41 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. | BI01010001010000000000000515BI0100001158 | 105 | sqm |
42 | 42 | (Plumbing and Sanitary works) | BI01010001010000000000000515BI0100001160 | ||
43 | 43 | Providing and fixing one no.stainless steel hinged rail 76 cm & five nos. of stainless steel grab rails 60 cm of approved make as per drawing & as per manufactures specification .The rate is including cost and conveyance of all materials, labour charges, lead,lift,cutting and making good the walls,floors,slab wherever required etc complete, testing and commissioning to the satisfaction of Engineer in Charge as directed by the Engineer-in-charge at all levels. | BI01010001010000000000000515BI0100001161 | 1 | Each |
44 | 44 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : | BI01010001010000000000000515BI0100001162 | 10 | Each |
45 | 45 | Providing & fixing of star white vitreous china wash basin of approved size, C P brass waste assembly, wall flanges and rubber adapters for waste connection,angle valve, pillar cock, complete including CI/MS brackets duly painted, nuts, washers, etc. The rate is including cost and conveyance of all materials,labour charges,lead.lift, cutting, making good the walls, floors, slab wherever required, testing and commissioning to the satisfaction of Engineer in Charge as per direction of Engineer-Incharge at all levels. | BI01010001010000000000000515BI0100001164 | 10 | Each |
46 | 46 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. | BI01010001010000000000000515BI0100001165 | 10 | Each |
47 | 47 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 33.5x32.5x45 cm or 26.5x31.5x44 cm sizes | BI01010001010000000000000515BI0100001166 | 2 | Each |
48 | 48 | Providing and fixing of star white vitreous china urinal division plate of minimum size 69x16.5x32.5 cm, approved quality and make with fittings/fastener including cutting and making good the walls, cost and conveyance of all material, labour charge, lead, lift, all taxes etc. complete as directed by the Engineer-in-Charge. | BI01010001010000000000000515BI0100001167 | 2 | Each |
49 | 49 | Providing and fixing CP brass sink cock with regular swinging spout with wall flange, 40mm CP brass bottle trap, CP brass waste coupling , angle valve etc as per IS: 13983 with C.I. brackets & stainless steel plug, including painting of fittings and brackets, cutting and making good the walls ,floors,slab wherever required,testing and commissioning to the satisfaction of Engineer in Charge:The rate is including cost and conveyance of all materials, labour charges, lead,lift etc complete as directed by the Engineer in charge at all levels. | BI01010001010000000000000515BI0100001168 | 1 | Each |
50 | 50 | Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm. | BI01010001010000000000000515BI0100001169 | 1 | Each |
51 | 51 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. Rectangular shape 453x357 mm | BI01010001010000000000000515BI0100001170 | 10 | Each |
52 | 52 | Providing and fixing towel bar : C.P. brass | BI01010001010000000000000515BI0100001171 | 10 | Each |
53 | 53 | Providing and fixing soap dish : C.P. brass | BI01010001010000000000000515BI0100001172 | 10 | Each |
54 | 54 | Providing and fixing CP brass bib cock of approved quality and make conforming to IS standards and weighing not less than 690 gms including cost and conveyance of all materials, labour charges, sundries,lead,lift,cutting and making good the walls,floors,slab etc complete, testing and commissioning to the satisfaction of Engineer in Charge as directed by the Engineer in charge at all levels.\n15 mm nominal bore | BI01010001010000000000000515BI0100001173 | 10 | Each |
55 | 55 | Providing and fixing PVC floor trap of 110mm outer dia(multitrap) including SS cockroach free floor grating with cup etc including cost and conveyance of all materials labour charges ,lead, lift, cutting and making good the walls and floors etc complete as directed by the Engineer -in-Charge at all levels. | BI01010001010000000000000515BI0100001174 | 10 | Each |
56 | 56 | Providing and fixing C.P. brass stop cock concealed with adjustable wall flange of standard design and of approved make conforming to IS: 8931 including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer-in-charge at all levels. 20 mm nominal bore | BI01010001010000000000000515BI0100001175 | 18 | Each |
57 | 57 | Providing and fixing shower set consisting of overhead shower single flow with single lever divertor with wall flange of approved make and model including cost and conveyance of all materials, labour charges, lead , lift etc., complete, testing and commissioning to the satisfaction of Engineer in Charge as directed by the Engineer-in-Charge at all levels. | BI01010001010000000000000515BI0100001176 | 2 | Each |
58 | 58 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge - Internal work- Exposed on wall | BI01010001010000000000000515BI0100001177 | ||
59 | 58.1 | 110mm OD (10 kg/cm2) | BI01010001010000000000000515BI0100001178 | 25 | Rm |
60 | 58.2 | 75 mm OD (10 kg/cm2) | BI01010001010000000000000515BI0100001179 | 25 | Rm |
61 | 58.3 | 50mm OD (10 kg/cm2) | BI01010001010000000000000515BI0100001180 | 25 | Rm |
62 | 59 | Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge - external works | BI01010001010000000000000515BI0100001181 | ||
63 | 59.1 | 160mm OD (10 kg/cm2) | BI01010001010000000000000515BI0100001182 | 150 | Rm |
64 | 59.2 | 110mm OD (10 kg/cm2) | BI01010001010000000000000515BI0100001183 | 40 | Rm |
65 | 59.3 | 75 mm OD (10 kg/cm2) | BI01010001010000000000000515BI0100001184 | 25 | Rm |
66 | 60 | Providing and fixing PVC vent cowl to pipe already fixed as directed by Engineer-in-Charge at all levels. | BI01010001010000000000000515BI0100001185 | ||
67 | 60.1 | 75 mm dia | BI01010001010000000000000515BI0100001186 | 7 | Each |
68 | 60.2 | 110 mm dia | BI01010001010000000000000515BI0100001187 | 7 | Each |
69 | 61 | Providing and fixing C.P. brass angle valve of 15 mm nominal bore conforming to IS:8931 including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer-in-Charge at all levels. | BI01010001010000000000000515BI0100001188 | 10 | Each |
70 | 62 | Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels | BI01010001010000000000000515BI0100001189 | ||
71 | 62.1 | 110mm dia | BI01010001010000000000000515BI0100001190 | 9 | Each |
72 | 62.2 | 75mm dia | BI01010001010000000000000515BI0100001191 | 9 | Each |
73 | 63 | Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 Cement : 4 coarse sand) R.C.C. top slab with 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete with 1:4:8 mix (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 Cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer-in-ChargeInside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight and frame 58 kg) : With bricks.Class designation 75 | BI01010001010000000000000515BI0100001192 | 6 | Each |
74 | 63.2 | Extra for depth for manholes.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001193 | 12 | Rm |
75 | 64 | Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil and unserviceable material as directed, within a lead of 50 m .\nPipes, cables etc. not exceeding 80mm dia | BI01010001010000000000000515BI0100001194 | 85 | Rm |
76 | 65 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | BI01010001010000000000000515BI0100001195 | 2000 | Ltr |
77 | 66 | Providing and fixing enclosed type water meter (bulk type) conforming to IS :2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :\n50mm | BI01010001010000000000000515BI0100001196 | 1 | Each |
78 | 67 | Supply, fixing and commissioning of pressure releasing valve 50mm with pressure setting from 0 to 7 Bar etc complete, 4 isolation valves, 2 preducing valves, 4 pressure gauge as per the requirement of the engineer in charge | BI01010001010000000000000515BI0100001197 | 1 | Each |
79 | 68 | Supply & Fixing of 50 mm dia gun metal Non Return Valve confirming to IS :14846 , PN 10 with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer- in-Charge at all levels. | BI01010001010000000000000515BI0100001198 | 1 | Each |
80 | 69 | Supply and installation of brass float valve of 40 mm dia with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer- in-Charge at all levels. | BI01010001010000000000000515BI0100001199 | 1 | Each |
81 | 70 | Providing and fixing bronze ball valve with screwed female/flanged ends with stainless steel valve and spindle, glass fileed tefelon seating and gland packing, quarter turn lever operate full bore design, hydraulically tested to 20 kg/sqcm complete in all respect as per approved design,make and quality as directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001200 | 5 | Each |
82 | 71 | Supplying, laying, and jointing schedule 40 UPVC ASTM pipe and Schedule 80 ASTM-UPVC specials of approved make such as tees elbows, unions,bends,sockets bends,flanges, reducers, end caps,saddles, plugs,coupling, etc. including cost of all jointing materials like solvent cement, bolts, nuts, rubber washers,ferrule,pipe supports, cost of extra wastage of fittings during laying of pipe line such as rectification and recharging of the existing line as and when required etc.hire of tools and plant, cost and conveyance of water for testing after connecting to mains including all testing pipe line to the specified hydrostatic test pressure,rectifying any leakage or defects etc. complete.as directed by Engineer-in-Charge for exposed water supply work | BI01010001010000000000000515BI0100001201 | ||
83 | 71.1 | 50 mm ID | BI01010001010000000000000515BI0100001202 | 60 | Rm |
84 | 71.2 | 40 mm ID | BI01010001010000000000000515BI0100001203 | 450 | Rm |
85 | 72 | Supplying, laying, and jointing schedule 40 UPVC ASTM pipe and Schedule 80 ASTM-UPVC specials of approved make such as tees elbows, unions,bends,sockets bends,flanges, reducers, end caps,saddles, plugs,coupling, etc. including cost of all jointing materials like solvent cement, bolts, nuts, rubber washers,ferrule,pipe supports, cost of extra wastage of fittings during laying of pipe line such as rectification and recharging of the existing line as and when required etc.hire of tools and plant, cost and conveyance of water for testing after connecting to mains including all testing pipe line to the specified hydrostatic test pressure,rectifying any leakage or defects etc. complete.as directed by Engineer-in-Charge for concealed line for water supply work | BI01010001010000000000000515BI0100001204 | ||
86 | 72.1 | 50 mm ID | BI01010001010000000000000515BI0100001205 | 30 | Rm |
87 | 72.2 | 20mm ID | BI01010001010000000000000515BI0100001206 | 35 | Rm |
88 | 73 | (Electrical works) \nCABLES AND CABLING\nSupply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date, complete in all respects as per technical specification. | BI01010001010000000000000515BI0100001207 | ||
89 | 73.1 | 3.5 C 70 Sq.mm Al | BI01010001010000000000000515BI0100001208 | 500 | Rm |
90 | 73.2 | 4C 10 Sq.mm Al | BI01010001010000000000000515BI0100001209 | 400 | Rm |
91 | 74 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete in all respect as per technical specification. | BI01010001010000000000000515BI0100001210 | ||
92 | 74.1 | 3.5 C 70 Sq.mm Al | BI01010001010000000000000515BI0100001211 | 2 | Each |
93 | 74.2 | 4C 10 Sq.mm Al | BI01010001010000000000000515BI0100001212 | 5 | Each |
94 | 75 | Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3.5 core, XLPE aluminium conductor cable of 1.1 KV grade as required.\n3.5C X70sq.mm. | BI01010001010000000000000515BI0100001213 | 1 | Each |
95 | 76 | Supply,installation ,testing and comissioning of maintenance free earthing using 4 mtrs length,20mm dia 250 microns molecularly copper bonded steel rod, stainless stell connectors and fasteners for connecting earth strip.The earth electrode shall be filled with earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound).FRP (UFE FRP)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 300mmx 300mmx 300mm with a weight bearing capacity of 15KN.The item shall be inclusive of installation charges,including digging bore,providing all required accessories like terminal connector,screw for fixing earth pit cover etc. | BI01010001010000000000000515BI0100001214 | 5 | Each |
96 | 77 | Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | BI01010001010000000000000515BI0100001215 | ||
97 | 77.1 | 25mm X 6mm GI | BI01010001010000000000000515BI0100001216 | 50 | Rm |
98 | 78 | Supplying and laying 8 SWG G.I. wire at 0.50 meter below ground\nlevel for conductor earth electrode, including connection/\ntermination with GI thimble etc. as required. | BI01010001010000000000000515BI0100001217 | 1700 | Rm |
99 | 79 | Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. | BI01010001010000000000000515BI0100001218 | ||
100 | 79.1 | 10 SWG Cu | BI01010001010000000000000515BI0100001219 | 60 | Rm |
101 | 80 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in\nrecess for connections etc. as required. | BI01010001010000000000000515BI0100001220 | 120 | Rm |
102 | 81 | Supplying and laying of following size DWC HDPE pipe ISI\nmarked along with all accessories like socket, bend, couplers\netc. conforming to IS 14930, Part II complete with fitting and\ncutting, jointing etc..direct in ground (75 cm below ground level)\nincluding excavation and refilling the trench but excluding sand\ncushioning and protective covering etc., complete as required. | BI01010001010000000000000515BI0100001221 | ||
103 | 81.1 | 160 mm dia (OD-160 mm & ID-135 mm nominal) | BI01010001010000000000000515BI0100001222 | 50 | Rm |
104 | 82 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall or surface as required. | BI01010001010000000000000515BI0100001223 | ||
105 | 82.1 | Upto 35 sq. mm (clamped with 1mm thick saddle) | BI01010001010000000000000515BI0100001224 | 40 | Rm |
106 | 82.2 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | BI01010001010000000000000515BI0100001225 | 50 | Rm |
107 | 83 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall or surface as required. | BI01010001010000000000000515BI0100001226 | ||
108 | 83.1 | Upto 35 sq. mm (clamped with 1mm thick saddle) | BI01010001010000000000000515BI0100001227 | 400 | Rm |
109 | 83.2 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | BI01010001010000000000000515BI0100001228 | 450 | Rm |
110 | 84 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/HDPE/ METAL pipe as required. | BI01010001010000000000000515BI0100001229 | ||
111 | 84.1 | Up to 35 sq.mm | BI01010001010000000000000515BI0100001230 | 30 | Rm |
112 | 84.2 | Above 35 sq. mm and upto 95 sq. mm | BI01010001010000000000000515BI0100001231 | 50 | Rm |
113 | 85 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required | BI01010001010000000000000515BI0100001232 | ||
114 | 85.1 | 150 mm dia | BI01010001010000000000000515BI0100001233 | 30 | Rm |
115 | 86 | Suppling and fixing cable route marker with 10cm X 10 cm X 5 mm thick G.I plate with inscription there on,bolted/welded to 35 mmX35 mm X 6 mm angle iron,60 cm long and fixing the same in ground as required. | BI01010001010000000000000515BI0100001234 | 15 | Each |
116 | 87 | MCBs AND MCB DISTRIBUTION BOARDS\nSupplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 125/160 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB’s/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) | BI01010001010000000000000515BI0100001235 | ||
117 | 87.1 | 4 Way TPN | BI01010001010000000000000515BI0100001236 | 1 | Each |
118 | 88 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | BI01010001010000000000000515BI0100001237 | ||
119 | 88.1 | 8 way (8 + 24), Double door | BI01010001010000000000000515BI0100001238 | 2 | Each |
120 | 89 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | BI01010001010000000000000515BI0100001239 | ||
121 | 89.1 | 12 way, Double door | BI01010001010000000000000515BI0100001240 | 2 | Each |
122 | 90 | Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. | BI01010001010000000000000515BI0100001241 | ||
123 | 90.1 | 6A to 32A, SP, C-CURVE | BI01010001010000000000000515BI0100001242 | 35 | Each |
124 | 90.2 | 6 A to 32 A TP MCB, C-CURVE | BI01010001010000000000000515BI0100001243 | 3 | Each |
125 | 91 | Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required. | BI01010001010000000000000515BI0100001244 | ||
126 | 91.1 | 2 pole 25 amps. (230 Volts),30mA sensitivity. | BI01010001010000000000000515BI0100001245 | 2 | Each |
127 | 91.2 | 4 pole 32 amps. (415 Volts),30mA sensitivity. | BI01010001010000000000000515BI0100001246 | 2 | Each |
128 | 92 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. | BI01010001010000000000000515BI0100001247 | ||
129 | 92.1 | 63Amp,16KA,FP MCCB | BI01010001010000000000000515BI0100001248 | 1 | Each |
130 | 93 | WIRING AND ACCESSORIES\nWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Total distance from switch board to first point will not exceed 5 metres, incase if the length exceeds 5 metres , the additional length shall be measured under item 96.1 | BI01010001010000000000000515BI0100001249 | 85 | Each |
131 | 94 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Total distance from point to point point will not exceed 5 metres, incase if the length exceeds 5 metres , the additional length shall be measured under item 96.1 | BI01010001010000000000000515BI0100001250 | 3 | Each |
132 | 95 | Wiring for group controlled (looped) light point/fan point/ exhaust fan point/ call bell point(without independent switch etc.) with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required..Total distance from point to point will not exceed 5 metres, incase if the length exceeds 5 metres , the additional length shall be measured under item 96.1 | BI01010001010000000000000515BI0100001251 | 21 | Each |
133 | 96 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. | BI01010001010000000000000515BI0100001252 | ||
134 | 96.1 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | BI01010001010000000000000515BI0100001253 | 200 | Rm |
135 | 96.2 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | BI01010001010000000000000515BI0100001254 | 600 | Rm |
136 | 96.3 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | BI01010001010000000000000515BI0100001255 | 250 | Rm |
137 | 96.4 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | BI01010001010000000000000515BI0100001256 | 40 | Rm |
138 | 97 | Supplying and drawing following sizes of FRLSH PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | BI01010001010000000000000515BI0100001257 | ||
139 | 97.1 | 3 X 1.5 sq. mm | BI01010001010000000000000515BI0100001258 | 30 | Rm |
140 | 97.2 | 3 X 2.5 sq. mm | BI01010001010000000000000515BI0100001259 | 50 | Rm |
141 | 97.3 | 3 X 4 sq. mm | BI01010001010000000000000515BI0100001260 | 20 | Rm |
142 | 98 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | BI01010001010000000000000515BI0100001261 | 74 | Each |
143 | 99 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box,fan hook etc. as required. | BI01010001010000000000000515BI0100001262 | 22 | Each |
144 | 100 | Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc as required. | BI01010001010000000000000515BI0100001263 | 10 | Each |
145 | 101 | Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 20+/-2 Watts,lumen output of lamp greater than 1500, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Wipro LL20-221-XXX-60-XX or Crompton Greaves DMLN1LT16+LT16 | BI01010001010000000000000515BI0100001264 | 63 | Each |
146 | 102 | Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 10+/-2 Watts,lumen output of lamp greater than 800, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Wipro LL20-121-XXX-60-XX or Crompton Greaves DMLN1LT16+LT8 | BI01010001010000000000000515BI0100001265 | 11 | Each |
147 | 103 | Supply of following sizes of 1200 mm sweep. 5 star rated ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, 30 cm down rod and without speed regulator suitable for 240V 50 HZ, AC supply confirms to IS 374/1979 as required complete. (Make crompton-High Speed or equivalent approved make). | BI01010001010000000000000515BI0100001266 | 22 | Each |
148 | 104 | Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton Brisk Air or equivalant approved make) | BI01010001010000000000000515BI0100001267 | 10 | Each |
149 | 105 | Supply, Installation,Testing and Commissioning of minimum 1.5 TR Split air conditioning unit (BEE 5 Star Rated) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor,R410a/407c refrigerant, including fixing the outdoor unit as per manufacturers recommendation and fixing of room (High wall) unit on wall, fully copper coils with hydrophilic coating providing copper piping interconnection with 19mm thick round closed cell elastomeric nitrile rubber Class 'O' insulation applied by adhesive confirming to standard specification ,finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, between Indoor & outdoor unit as per site conditions, necessary power and control cabling (indoor to outdoor), outdoor vibration isolators, suitable size CPVC drain pipe with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including chasing, drilling, concealing and making good the same on walls etc.vibration isolators, charging of refrigerant gas, MS condenser stand, cordless remote etc complete as required. Suitable for single phase 230 V supply and with suitable stabilizer etc complete in all respects as per the technical Specifcation . | BI01010001010000000000000515BI0100001268 | 2 | Each |
150 | 106 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001269 | 4 | Each |
151 | 107 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | BI01010001010000000000000515BI0100001270 | 7 | Each |
152 | 108 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | BI01010001010000000000000515BI0100001271 | 66 | Each |
153 | 109 | Supply, erecting, installing testing and commissioning of 7 meter street light pole and 55+/-5 W LED street light. The pole made out of hot dip galvanised 3 mm thick MS sheet, primered and polyurethane painted cylindrical pole with a bracket . The pole should have a flush door at bottom with inbuilt control box, proper cutout and provision for mounting DP MCB,four pole connector for easy loop-in loop-out,concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture. The pole shall be installed on existing civil foundation with foundation bolt. Along with LED street lighting fixture with die cast aluminium housing ,system wattage maximum of 60 Watts,lumen output of lamp greater than 5500 lumens, power factor > 0.9,rated life of L70 @ 40,000 hours, system efficacy greater than 90 lumen/watts, with suitable driver IP 65 complaint and including all necessary accessories as required complete.Make of pole:- Klite pole or equivalent approved Make:- Cat No: WIPRO LR02-671-XXX-57-XX, bajaj BRTFG60W,LT A05557M00 or equivalent approved make.\n | BI01010001010000000000000515BI0100001272 | ||
154 | 109.1 | Supply | BI01010001010000000000000515BI0100001273 | 20 | Each |
155 | 109.2 | ITC | BI01010001010000000000000515BI0100001274 | 20 | Each |
156 | 110 | Supply of 24 Port Ethernet Network Switch with all necessary hardware & accessories, etc. as required at site as per specification. | BI01010001010000000000000515BI0100001275 | 1 | Each |
157 | 111 | Installation,Testing and Commissioning of 24 Port switch with all necessary hardware & accessories, etc. as required at site as per specification. | BI01010001010000000000000515BI0100001276 | 1 | Job |
158 | 112 | Supply of CAT6 24 port patch panel with shutter fully loaded with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001277 | 1 | Each |
159 | 113 | Installation, testing and commissioning of cat6 24 port patch panel with shutter fully loaded, including termination, etc. with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001278 | 1 | Job |
160 | 114 | Supply of 25mm PVC conduit along with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001279 | 200 | Rm |
161 | 115 | Fixing of 25mm PVC conduit including all necessary accessories including recessing and making good the surface as required at site as per specification. | BI01010001010000000000000515BI0100001280 | 200 | Rm |
162 | 116 | Supply of Dual Shuttered Face Plate with all accessories required with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001281 | 15 | Each |
163 | 117 | Installation of Dual Shuttered Face Plate with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001282 | 15 | Each |
164 | 118 | Supply of Single Shuttered Face Plate with all accessories required with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001283 | 5 | Each |
165 | 119 | Installation of Single Shuttered Face Plate with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001284 | 5 | Each |
166 | 120 | Supply of UTP Patch Cords (1 m) Category 6 with end terminaiton for both data and voice with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001285 | 15 | Each |
167 | 121 | Installation, Testing and Commissioning of CAT6 UTP Patch Cords with end terminaiton for both data and voice with all accessories including termination, numbering tags ,Cable ties, Ferrules with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001286 | 15 | Job |
168 | 122 | Supply of U/UTP cable - Category 6 , 4 pair, 23 AWG solid copper conductor, 600 MHz, CMR, FRLSZH - with all accessories required at site as per specification | BI01010001010000000000000515BI0100001287 | 300 | Rm |
169 | 123 | Laying, testing and commission of CAT 6 U/UTP with Fluke DTX 1800 Cable Analyser through existing conduits in surface including termination, numbering tags ,Cable ties, Ferrules and all accessories required at site as per specification. | BI01010001010000000000000515BI0100001288 | 300 | Job |
170 | 124 | Supply of CAT6 Information Outlet for Data/Voice, RJ 45 with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001289 | 20 | Each |
171 | 125 | Laying of CAT6 Information Outlet for Data/Voice, RJ 45 with all accessories required including termination complete, etc. at site as per specification. | BI01010001010000000000000515BI0100001290 | 20 | Each |
172 | 126 | Supply of Metal Back Box for CAT 6 information outlet with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001291 | 15 | Each |
173 | 127 | Installation of Metal Back Box in recess for CAT 6 information outlet with all accessories required at site as per specification. | BI01010001010000000000000515BI0100001292 | 15 | Each |
174 | 128 | Supply of 9U wall mount 600x 550 MM Rack alongwith all necessary hardware & accessories, etc.complete as required at site as per specification. | BI01010001010000000000000515BI0100001293 | 1 | Each |
175 | 129 | Installation,Testing and Commissioning of 9U Rack along with all necessary hardware & accessories, etc.complete as required at site as per specification. | BI01010001010000000000000515BI0100001294 | 1 | Job |
176 | 130 | Supply of 10-Pair Krone Module | BI01010001010000000000000515BI0100001295 | 2 | Each |
177 | 131 | Supply of Steel Back Mounting Frame for 10 Krone Module | BI01010001010000000000000515BI0100001296 | 1 | Each |
178 | 132 | Installation,Testing and Commissioning of 10-Pair Krone Module | BI01010001010000000000000515BI0100001297 | 2 | Job |
179 | 133 | Supply of Telephone Wire (90m Length) - 2 Pair | BI01010001010000000000000515BI0100001298 | 2 | Rm |
180 | 134 | Laying of Telephone Cable | BI01010001010000000000000515BI0100001299 | 450 | Rm |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy