Repair Of Various Hvac Equipment Of 3X150 Mw Baglihar Hydroelectric Project Stage-I At Chanderkote, EXECUTIVE ENGINEER MECHANICAL DIVISION BHEP-Jammu And Kashmir

Jammu And Kashmir State Power Development Corporation Limited has published Repair Of Various Hvac Equipment Of 3X150 Mw Baglihar Hydroelectric Project Stage-I At Chanderkote. Submission Date for this Tender is 02-12-2019. Miscellaneous Fasteners Tenders in EXECUTIVE ENGINEER MECHANICAL DIVISION BHEP Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

22325817
Repair Of Various Hvac Equipment Of 3X150 Mw Baglihar Hydroelectric Project Stage-I At Chanderkote
Tender
Indian
Jammu And Kashmir
Executive Engineer Mechanical Division Bhep
02-12-2019

Tender Details

Repair Of Various Hvac Equipment Of 3X150 Mw Baglihar Hydroelectric Project Stage-I :-1. Repair Of Chillers 02 No. ( Blue Star Make ) With 26 Tr Capacity Each Located At Control Block Of Power House-I By Way Of Disassembling The Whole System For Cleaning Of Water Conductor And Then Assembling The Whole System Properly To Ensure The Proper Working Of The Chillers. 2. Overhauling Of Cold Water Pumps By Opening The Pumps And Removal Of Water Leakage From The Pumps Of The Chillers. 3. Repair Of Water Conducting System For Removing Water Leakage And Overhauling Of Booster Pumps Of The Chillers. 4. Filling Of Refrigerant R-22 If Required By Checking For Leakage By Vacuuming Copper Coils And Then Filling Them With Nitrogen Gas And By Fitting Pressure Gauge And Keeping It For At Least 24 Hours To Check For Pressure Drop. Tracing Leakage By Detergent And Then Repair Of The Same. 5. Repair Of Sab-Ii Of Capacity 22, 500 M3 / H Located At Collection Gallery By Way Of Disassembling The Whole Body And Machinery And Replacing Of Old Damaged Impeller Of Diameter 710 Mm ( Backward Curved ) Made Of Mild Steel And Other Damaged Parts That May Include C 40 Carbon Steel Shaft Gi Casing, Replacement Of Old Bearing ( Deep Groove Ball / Spherical Roller ) And Then Reassembling Of Whole System After Proper Cleaning Of All The Parts. Checking Of Whole System For Leveling Of Foundation And Adjustment Of All Dimensions As Per Specifications For Smooth Running Of Sab. 6. Repair Of Electric Motor Crompton / Abb Tefc Sq. Cage Induction Motor 7.5 Kw 415 ± 10 % V, 3 Phase, 50 Hz 1470 Rpm 4 Pole With Frame Size 132 S 7. Repair / Replacement Of Motorized Multi Blade Dampers At Fan Outlet Of Size 898X898mm With Aluminum Frame & Blade With Model Nm230, 0N / Close Type 230 V, 1 Phase, 50 Hz Power Supply And 2W Power Consumption. 8. Repair Of Sab-V & Iv Of Capacity 11, 455 M3 / H Located At Gate Chamber By Way Of Disassembling The Whole Body Including Centrifugal Fan, Fan Outlet Flexible Connections And Electric Motor. Replacement Of Old Bearing ( Deep Groove Ball / Spherical Roller ) Impeller Side And Then Reassembling Of Whole System After Proper Cleaning Of All The Parts. Checking Of Whole System For Leveling Of Foundation And Adjustment Of All Dimensions As Per Specifications For Smooth Running Of Sab. 9. Repair Of Electric Motor By Way Of Opening Of Complete Set Checking Of Connections And Replacement Of Motor Bearings Of Crompton Make / Abb Tefc Sq. Cage Induction Motor 3.7 Kw 415 ± 10 % V, 3 Phase, 50 Hz 1470 Rpm 4 Pole With Frame Size 112 M ( Per Requirement ) 10. Repair / Replacement Of Motorized Multi Blade Dampers At Fan Outlet Of Size 568X568mm With Ms Frame & Blade With Model Nm230, 0N / Close Type 230 V, 1 Phase, 50 Hz Power Supply And 2W Power Consumption. 11. Repair Of Ahu-Iii Of Capacity 47, 500 M3 / H Located 12. Repairs To The Foundation Of Ahu -Iii By Removing The Damaged Parts, Painting Steel Work ( Steel Girder ) With Deluxe Multi Surface Paint Of Required Shade To Give An Even Shade, Two Or More Coats Applied @ 0.90 Litre / 10 M2over An Under Coat Of Primer Applied @ 0.80 Litre / 10 M2 Of Approved Brand And Manufacture, 13. Repair Of Ahus Viii, Ix, X Of Capacity 45, 000 M3 / H Each Located At Control Block By Way Of Disassembling The Whole Body Including Centrifugal Fan, Fan Outlet Flexible Connections And Electric Motor And Doing Proper Repairs To The Foundation Of The Unit By Removing The Damaged Parts And Proper Leveling Of The Unit And Then Reassembling Of Whole System After Proper Cleaning Of All The Parts And Adjustment Of All Dimensions As Per Specifications For Smooth Running Of Ahu. 14. Repair Of 03 No. Faus Of Capacity 45, 000 M3 / H Each Located At Control Block And Gis Hall By Way Of Disassembling The Whole Body And Machinery And Replacing / Repairing Of Cooling Coils And Heating Coils Of 4.92 M2 Face Area With Dimensions Of 952.5X2582mm, 2 Sections, Tube Size 12.5Mm Od And 12Fins / Inch And Then Reassembling The Whole System After Checking Of Whole System For Leveling Of Foundation And Adjustment Of All Dimensions As Per Specifications For Smooth Running Of All Faus. 15. Repair Of Motorized Multi Blade Dampers Of Fau’S At Fan Outlet Of Size 1130X1130 Mm Of Aluminum Of Belimo, Switzerland Make Of Actuator Model Nm230 On / Close Type With Power Supply Of 230 V 1 Phase, 50 Hz And Power Consumption Of 2W 16. Repair Of Doors Of 25 No. Units ( Ahus, Faus, Sabs & Eaus ) And Panel Doors ( 17 No. ) Of Hvac System Of Power House-I By Changing Defective Hinges, Handles And Locks Of Reputed Make. 17. Providing And Fitting Of Lighting System ( Led Bulb, Bulb Case, Automatic On / Off Switch Operable By Opening And Closing Of Door, Wires Etc. ) Inside All The Units And Panels Of The Hvac System And Proper Fixing Of The Same Doors At Their Respective Places.

Key Value

Document Fees
INR 1000 /-
Tender Value
INR 24.90 Lakhs /-