| 1 | 1 | Services | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.01 | Canopy Works | BI01010001010000000000000515BI0100001113 | | |
|---|
| 3 | 1.02 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: | BI01010001010000000000000515BI0100001114 | 14080 | KG |
|---|
| 4 | 1.03 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth within and outside site to unobjectionable place, disposed earth to be levelled and neatly dressed. | BI01010001010000000000000515BI0100001115 | | |
|---|
| 5 | 1.04 | ii) Ordinary rock | BI01010001010000000000000515BI0100001116 | 90 | M3 |
|---|
| 6 | 1.05 | Providing and laying Dry brick on edge flooring in required pattern with bricks of Class designation 75 on a bed of 12mm mud mortar including filling joints with fine sand complete. | BI01010001010000000000000515BI0100001117 | 36 | M2 |
|---|
| 7 | 1.06 | Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments,pillars,posts,struts, buttresses,string or lacing courses, parapets,coping, bed blocks, anchor blocks, plain window sills, fillets etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : | BI01010001010000000000000515BI0100001118 | | |
|---|
| 8 | 1.07 | vii)PCC 1 Cement:3 Fine Sand:6 Graded Stone Aggregate 40mm | BI01010001010000000000000515BI0100001119 | 3.6 | M3 |
|---|
| 9 | 1.08 | Supply of Reinforcement for R.C.C. including straightening, cutting, bending, placing in position & binding all complete at all levels | BI01010001010000000000000515BI0100001120 | | |
|---|
| 10 | 1.09 | ii)Thermo Mechanically Treated Bars Fe- 500 grade,Conforming to IS1786 | BI01010001010000000000000515BI0100001121 | 2020 | KG |
|---|
| 11 | 1.1 | Providing and laying in position specified grade of reinforced concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level | BI01010001010000000000000515BI0100001122 | | |
|---|
| 12 | 1.11 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm | BI01010001010000000000000515BI0100001123 | 20.5 | M3 |
|---|
| 13 | 1.12 | Centering and shuttering including strutting, propping etc. and removal of form for : | BI01010001010000000000000515BI0100001124 | | |
|---|
| 14 | 1.13 | i) Foundations,footings,bases of columns, etc. for mass concrete | BI01010001010000000000000515BI0100001125 | 45 | M2 |
|---|
| 15 | 1.14 | Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : | BI01010001010000000000000515BI0100001126 | | |
|---|
| 16 | 1.15 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate | BI01010001010000000000000515BI0100001127 | 32 | EA |
|---|
| 17 | 1.16 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. | BI01010001010000000000000515BI0100001128 | | |
|---|
| 18 | 1.17 | iii) 160 mm diameter PVC Rain water pipe | BI01010001010000000000000515BI0100001129 | 28 | M |
|---|
| 19 | 1.18 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : | BI01010001010000000000000515BI0100001130 | | |
|---|
| 20 | 1.19 | ii) Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets with common burnt clay bricks of class designation 75 | BI01010001010000000000000515BI0100001131 | 4 | EA |
|---|
| 21 | 1.2 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty | BI01010001010000000000000515BI0100001132 | | |
|---|
| 22 | 1.21 | iv) 300 mm dia. R.C.C. pipe | BI01010001010000000000000515BI0100001133 | 90 | M |
|---|
| 23 | 1.22 | Providing & fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.50mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, with 5-7 micron epoxy primer and polyester top coat of 15-18 micron on both sides,total coated thickness(TCT) of 0.58mm.Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. | BI01010001010000000000000515BI0100001134 | | |
|---|
| 24 | 1.23 | i) Profile Sheet for roofing | BI01010001010000000000000515BI0100001135 | 256 | M2 |
|---|
| 25 | 1.24 | iii) Plain sheet for Flashings/ Aprons.( Upto 600 mm) | BI01010001010000000000000515BI0100001136 | 96 | M2 |
|---|
| 26 | 1.25 | Providing and fixing 700mm wide rain water gutter fabricated out of 1200mm wide Roll of 18 Gauge Aluminium sheets including MS clamp supports, fittings, fasteners etc. complete as per drawing . (NO joints shall be provided in the gutter and the same has to be fabricated from a continuous roll of Aluminium sheet) | BI01010001010000000000000515BI0100001137 | 64 | M |
|---|
| 27 | 1.26 | Providing ridges or hips of width 60cm over all width plain G.S.sheet 0.80mm thick with zinc coating not less than 275gm/m², fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. | BI01010001010000000000000515BI0100001138 | 39 | M |
|---|
| 28 | 1.27 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of cold rolled steel sheet conforming to IS 513, having minimum yield stress of 240mpa & minimum tensile stress of 300mpa.Base metal thickness 0.45mm for ceiling panels and 0.55mm for carriers. The sheet shall be hot dip metallic coated with Zinc coating ( galvanising) as per IS 277, coating mass of 120gsm on both sides, over which organic coating with Modified polyester paint on a continuous coil coating line. Top side of ceiling panels and carrier shall have 15 micron modified polyester paint over 5 micron epoxy primer and Bottom side with Alkyd back coat over 5 micron primer Total coated thickness for Panels to be 0.50mm and for carriers 0.60mm. The ceiling panels shall be clipped in to carriers, suspended from steel/trusses /other members with the help of suspension angle of 25x25x0.5mm by means of rigid suspension system meant for exterior. Longitudinal joints of two panels shall be but jointed with special type of panel splice to be fixed from inner side.Carrier shall be jointed with carrier splices maintaining a module of 150mm | BI01010001010000000000000515BI0100001139 | 256 | M2 |
|---|
| 29 | 1.28 | CABLING & ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. wherever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items | BI01010001010000000000000515BI0100001140 | | |
|---|
| 30 | 1.29 | Supply and Laying 3 Core x 2.5 sq. mm Copper Cable FRLS as per specifications and direction of Engineer in charge | BI01010001010000000000000515BI0100001141 | 200 | M |
|---|
| 31 | 1.3 | CABLING & ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. wherever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items | BI01010001010000000000000515BI0100001142 | | |
|---|
| 32 | 1.31 | Supply and Laying 4 Core x 16 sq. mm Aluminium Cable FRLS as per specifications and direction of Engineer in charge | BI01010001010000000000000515BI0100001143 | 40 | M |
|---|
| 33 | 1.32 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compression cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. | BI01010001010000000000000515BI0100001144 | | |
|---|
| 34 | 1.33 | P/F cable termination for 3 Core x 2.5 sq. mm with Non FLP double compression glands,lugs etc. as per specifications and direction of Engineer-in charge. | BI01010001010000000000000515BI0100001145 | 8 | EA |
|---|
| 35 | 1.34 | Supply & Fixing of Weatherproof (IP-65) Thermoplastic Cable Junction Box with terminal block fitted inside the box suitable for following cable sizes. | BI01010001010000000000000515BI0100001146 | | |
|---|
| 36 | 1.35 | for 2.5 sq.mm. cable entry size with 9 terminals | BI01010001010000000000000515BI0100001147 | 8 | EA |
|---|
| 37 | 1.36 | MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive of MCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) | BI01010001010000000000000515BI0100001148 | | |
|---|
| 38 | 1.37 | 6 way DB with 63A FP RCBO, 300 mA sensitivity as incoming - 1No. & 6 to 16A SP as outgoing - 6 Nos. for each phase. | BI01010001010000000000000515BI0100001149 | 1 | EA |
|---|
| 39 | 1.38 | FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Beluga/CEAG-FCG /Flexor/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. | BI01010001010000000000000515BI0100001150 | | |
|---|
| 40 | 1.39 | P/F Cable termination for 3 Core x 2.5 sq. mm with FLP double compression glands, lugs etc. as per specifications and direction of Engineer-in charge. | BI01010001010000000000000515BI0100001151 | 10 | EA |
|---|
| 41 | 1.4 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture | BI01010001010000000000000515BI0100001152 | 192 | M2 |
|---|
| 42 | 1.41 | Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : | BI01010001010000000000000515BI0100001153 | | |
|---|
| 43 | 1.42 | Supply & Laying Earthing 32 x 6 mm G.I.strip as per specifications and direction of Engineer in Charge. | BI01010001010000000000000515BI0100001154 | 180 | M |
|---|
| 44 | 1.43 | 80W LED CANOPY LIGHTS | BI01010001010000000000000515BI0100001155 | 16 | EA |
|---|
| 45 | 1.44 | Paver Block Driveway | BI01010001010000000000000515BI0100001156 | | |
|---|
| 46 | 1.45 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth within site and lift upto 1.5 m, disposed soil to be levelled and neatly dressed | BI01010001010000000000000515BI0100001157 | 100 | M2 |
|---|
| 47 | 1.46 | Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering - All work up to plinth level : | BI01010001010000000000000515BI0100001158 | | |
|---|
| 48 | 1.47 | iii)1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) | BI01010001010000000000000515BI0100001159 | 8 | M3 |
|---|
| 49 | 1.48 | Providing and laying in position specified grade of reinforced concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level | BI01010001010000000000000515BI0100001160 | | |
|---|
| 50 | 1.49 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm | BI01010001010000000000000515BI0100001161 | 10 | M3 |
|---|
| 51 | 1.5 | Centering and shuttering including strutting, propping etc. and removal of form for : | BI01010001010000000000000515BI0100001162 | | |
|---|
| 52 | 1.51 | i) Foundations,footings,bases of columns, etc. for mass concrete | BI01010001010000000000000515BI0100001163 | 30 | M2 |
|---|
| 53 | 1.52 | Supply of Reinforcement for R.C.C. including straightening, cutting, bending, placing in position & binding all complete at all levels | BI01010001010000000000000515BI0100001164 | | |
|---|
| 54 | 1.53 | ii)Thermo Mechanically Treated Bars Fe- 500 grade,Conforming to IS1786 | BI01010001010000000000000515BI0100001165 | 450 | KG |
|---|
| 55 | 1.54 | Providing and laying Brick work with bricks of class designation 75 Including Scaffolding : | BI01010001010000000000000515BI0100001166 | | |
|---|
| 56 | 1.55 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH | BI01010001010000000000000515BI0100001167 | 6 | M3 |
|---|
| 57 | 1.56 | Providing and laying cement plaster on surfaces with Coarse sand including curing etc. | BI01010001010000000000000515BI0100001168 | | |
|---|
| 58 | 1.57 | ii) 12mm Cement plaster of mix1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001169 | 10 | M2 |
|---|
| 59 | 1.58 | Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer | BI01010001010000000000000515BI0100001170 | 600 | M2 |
|---|
| 60 | 1.59 | Providing & laying 80mm thick factory made Pre-cast cement concrete interlocking paver block of M 40 grade made by block making machine with strong vibratory compaction & of approved size and design/ shape shade and manufacturers and as per IOCL's specifications. The paver block will have peripheral chamfer,with average crushing strength more than 40 N/Sq.mm as/ BS6717 Part -1(1986), maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length & width and +/- 3mm on on thickness. The job includes supplying & laying a layer of 50mm thick clean course sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand,compacting with machine vibrator to required line and level, etc. complete.(Payment for provision of edge restraints shall be made separately);- Grey or Coloured 80mm thick paver blocks | BI01010001010000000000000515BI0100001171 | 600 | M2 |
|---|
| 61 | 1.6 | Yard Lighting | BI01010001010000000000000515BI0100001172 | | |
|---|
| 62 | 1.61 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth within and outside site to unobjectionable place, disposed earth to be levelled and neatly dressed. | BI01010001010000000000000515BI0100001173 | | |
|---|
| 63 | 1.62 | i) All kinds of Soil | BI01010001010000000000000515BI0100001174 | 6 | M3 |
|---|
| 64 | 1.63 | Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering - All work up to plinth level : | BI01010001010000000000000515BI0100001175 | | |
|---|
| 65 | 1.64 | iii)1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) | BI01010001010000000000000515BI0100001176 | 2 | M3 |
|---|
| 66 | 1.65 | Providing and laying in position specified grade of reinforced concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level | BI01010001010000000000000515BI0100001177 | | |
|---|
| 67 | 1.66 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm | BI01010001010000000000000515BI0100001178 | 1.5 | M3 |
|---|
| 68 | 1.67 | Centering and shuttering including strutting, propping etc. and removal of form for : | BI01010001010000000000000515BI0100001179 | | |
|---|
| 69 | 1.68 | i) Foundations,footings,bases of columns, etc. for mass concrete | BI01010001010000000000000515BI0100001180 | 12 | M2 |
|---|
| 70 | 1.69 | Supply of Reinforcement for R.C.C. including straightening, cutting, bending, placing in position & binding all complete at all levels | BI01010001010000000000000515BI0100001181 | | |
|---|
| 71 | 1.7 | ii)Thermo Mechanically Treated Bars Fe- 500 grade,Conforming to IS1786 | BI01010001010000000000000515BI0100001182 | 200 | KG |
|---|
| 72 | 1.71 | CABLING & ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. wherever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items | BI01010001010000000000000515BI0100001183 | | |
|---|
| 73 | 1.72 | Supply and Laying 3 Core x 2.5 sq. mm Copper Cable FRLS as per specifications and direction of Engineer in charge | BI01010001010000000000000515BI0100001184 | 240 | M |
|---|
| 74 | 1.73 | FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Beluga/CEAG-FCG /Flexor/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. | BI01010001010000000000000515BI0100001185 | | |
|---|
| 75 | 1.74 | P/F Cable termination for 3 Core x 2.5 sq. mm with FLP double compression glands, lugs etc. as per specifications and direction of Engineer-in charge. | BI01010001010000000000000515BI0100001186 | 6 | EA |
|---|
| 76 | 1.75 | Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen | BI01010001010000000000000515BI0100001187 | 90 | M |
|---|
| 77 | 1.76 | Supplying and providing 100mm square Hansel weather proof junction box for emblem pole/ light pole/yard light | BI01010001010000000000000515BI0100001188 | 6 | EA |
|---|
| 78 | 1.77 | Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete. | BI01010001010000000000000515BI0100001189 | | |
|---|
| 79 | 1.78 | S/E Arm \" L \" bracket 38/50mm dia on pole , as per specifications and direction of Engineer in charge | BI01010001010000000000000515BI0100001190 | 6 | EA |
|---|
| 80 | 1.79 | Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. | BI01010001010000000000000515BI0100001191 | | |
|---|
| 81 | 1.8 | L Pole | BI01010001010000000000000515BI0100001192 | 6 | EA |
|---|
| 82 | 1.81 | OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separately) : | BI01010001010000000000000515BI0100001193 | | |
|---|
| 83 | 1.82 | 7 Meter high galvanized Octagonal pole with top 70mm (A/F), bottom bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 220 x 220 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanized foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) | BI01010001010000000000000515BI0100001194 | 6 | EA |
|---|
| 84 | 1.83 | Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : | BI01010001010000000000000515BI0100001195 | | |
|---|
| 85 | 1.84 | Supply & Laying Earthing 32 x 6 mm G.I.strip as per specifications and direction of Engineer in Charge. | BI01010001010000000000000515BI0100001196 | 120 | M |
|---|
| 86 | 1.85 | S/F 100W LED YARD LIGHT FITTING | BI01010001010000000000000515BI0100001197 | 6 | EA |
|---|