Construction Of Balance Portion Of 32 Men Barrack Type A Toilet Block 02 Nos Central Morcha 04 Nos Corner Bunker 02 Nos 2 Men Bunkers Sentry Post Development Works And Furniture/Fixtures At Bop Jodhawala Of 169 Bn Bsf Now 52 Bn Bsf Shq Bsf Abohar Sh Elec, BOP JODHAWALA-Punjab

Border Security Force-BSF has published Construction Of Balance Portion Of 32 Men Barrack Type A Toilet Block 02 Nos Central Morcha 04 Nos Corner Bunker 02 Nos 2 Men Bunkers Sentry Post Development Works And Furniture/Fixtures At Bop Jodhawala Of 169 Bn Bsf Now 52 Bn Bsf Shq Bsf Abohar Sh Elec. Submission Date for this Tender is 04-11-2019. Barrack Tenders in BOP JODHAWALA Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

22297444
Construction Of Balance Portion Of 32 Men Barrack Type A Toilet Block 02 Nos Central Morcha 04 Nos Corner Bunker 02 Nos 2 Men Bunkers Sentry Post Development Works And Furniture/Fixtures At Bop Jodhawala Of 169 Bn Bsf Now 52 Bn Bsf Shq Bsf Abohar Sh Elec
Open Tender
Indian
Punjab
BOP JODHAWALA
04-11-2019

Tender Details

Construction Of Balance Portion Of 32 Men Barrack Type A Toilet Block 02 Nos Central Morcha 04 Nos Corner Bunker 02 Nos 2 Men Bunkers Sentry Post Development Works And Furniture/Fixtures At Bop Jodhawala Of 169 Bn Bsf Now 52 Bn Bsf Shq Bsf Abohar Sh Electrical

Key Value

Document Fees
INR 500 /-
EMD
INR 1024184.0 /-
Tender Value
INR 10.24 Lakhs /-

BOQ Items

Name of Work: C/O Balance Portion of 32 Men Barrack (Type A), Toilet Block, 02 Nos central morcha, 04 nos corner bunker, 02 nos 2 men bunkers, sentry post, development works and furniture/fixtures at BOP Jodhawala of 169 BN BSF(now 52 bn BSF) SHQ BSF ABOHAR Punjab FTR (Sh : Electrical work)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group 'B'\n\n\n BI01010001010000000000000515BI0100001113 184 Point
2 2 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required\n\n.\n BI01010001010000000000000515BI0100001114 140 metre
3 3 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.\n\n\n BI01010001010000000000000515BI0100001115 25 metre
4 4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (.) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire BI01010001010000000000000515BI0100001116 260 metre
5 5 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. a) 3 x 1.5 sq. Mm BI01010001010000000000000515BI0100001117 18 metre
6 6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. b) 3 x 4 sq. Mm BI01010001010000000000000515BI0100001118 10 metre
7 7 Supplying and drawing 4 Pair, 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.\n BI01010001010000000000000515BI0100001119 25 metre
8 8 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. BI01010001010000000000000515BI0100001120 25 metre
9 9 Supplying and fixing of following sizes of 20 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required of 20 MM\n\n BI01010001010000000000000515BI0100001121 40 metre
10 10 Supplying and fixing of following sizes of 50 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required of 50 mm BI01010001010000000000000515BI0100001122 40 Mtr
11 11 Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required. a) 5/6 Amp. Switch BI01010001010000000000000515BI0100001123 62 each
12 12 Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required. b) 3 pin 5/6 Amp. Socket BI01010001010000000000000515BI0100001124 62 each
13 13 Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required. c) Telephone socket outlet BI01010001010000000000000515BI0100001125 2 each
14 14 Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required. d) TV Socket outlet BI01010001010000000000000515BI0100001126 2 each
15 15 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required BI01010001010000000000000515BI0100001127 24 Each
16 16 Supplying and fixing following modular G. I. box alongwith modular base & cover plate for modular switches in recess etc. as required. a) 2 Modular BI01010001010000000000000515BI0100001128 4 each
17 17 Supplying and fixing following modular G. I. box alongwith modular base & cover plate for modular switches in recess etc. as required. b) 4 Modular BI01010001010000000000000515BI0100001129 4 each
18 18 Supplying and fixing following modular G. I. box alongwith modular base & cover plate for modular switches in recess etc. as required. c) 6 Modular BI01010001010000000000000515BI0100001130 25 each
19 19 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. BI01010001010000000000000515BI0100001131 7 each
20 20 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required. BI01010001010000000000000515BI0100001132 86 each
21 21 Supplying and fixing PVC batten/ angle holder including connections etc. as required. BI01010001010000000000000515BI0100001133 10 each
22 22 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door BI01010001010000000000000515BI0100001135 9 each
23 23 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door BI01010001010000000000000515BI0100001136 3 each
24 24 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole BI01010001010000000000000515BI0100001137 66 Each
25 25 Supplying and fixing following rating, 40 Amp double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required BI01010001010000000000000515BI0100001138 9 each
26 26 Supplying and fixing following rating, 63 Amp double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required BI01010001010000000000000515BI0100001139 3 each
27 27 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required BI01010001010000000000000515BI0100001140 10 each
28 28 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick\nincluding accessories, and providing masonry enclosure with\ncover plate having locking arrangement and watering pipe of\n2.7 metre long etc. with charcoal/ coke and salt as required BI01010001010000000000000515BI0100001141 10 Set
29 29 Supplying and laying 6 SWG dia G.I. wire on surface or in recess for loop earthing surface/ recessed conduit/ submain wiring/ cable as required. BI01010001010000000000000515BI0100001142 94 metre
30 30 S/ITC of outdoor type feeder piller, double door made out of 14 SWG CRCA sheet of size 1000 mm x 900 mm x 350 mm deep having 100 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires, following accessories & angle iron frame of size 900 mm x 350 mm with 600 mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required CPRI Approved \na) 4 pole, 100 amps, 25 kA, 415 Volts, 50 Hz MCCB make Havells of 02 Nos \nb) 63 Amps, DP, Isolator, 240 V, 50 Hz, 10 kA make Havells of 04 Nos \nc) 63 Amps, 4 Pole, isolator, 240 V, 50 Hz, 10 kA make Havells BI01010001010000000000000515BI0100001143 1 each
31 31 Laying of one number PVC insulated and PVC sheathed / XLPE\npower cable of 1.1 KV grade of following size direct in ground\nincluding excavation and refilling the trench etc as required, but\nexcluding sand cushioning and protective covering.a)Upto 35 sq. mm BI01010001010000000000000515BI0100001144 400 mtrs
32 32 Laying of one number PVC insulated and PVC sheathed / XLPE\npower cable of 1.1 KV grade of following size in the existing\nRCC/ HUME/ METAL pipe as required.a)Upto 35 sq. mm BI01010001010000000000000515BI0100001145 32 mtrs
33 33 Laying of one number PVC insulated and PVC sheathed / XLPE\npower cable of 1.1 KV grade of following size in the existing\nmasonry open duct as required.a)Upto 35 sq. mm BI01010001010000000000000515BI0100001146 15 mtrs
34 34 Providing and fixing of 400 MM size Wall fan (metalic body) with suitable size fastners bolts for fixing of wall fan havells make with wire complete with connection, testing commissioning etc as required. Make CG/Bajaj BI01010001010000000000000515BI0100001147 15 each
35 35 Supplying and fixing Decorative wall light fixture made up of Polycarbonate, suitable of havells of city-1 or city-2 , including providing and fixing of 9/10 watt LUMENO LED Lamp & making connections etc. as required of Make CG/Bajaj/Havells/Philips BI01010001010000000000000515BI0100001148 7 Each
36 36 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering Above 95 sq. mm and upto 185 sq. mm BI01010001010000000000000515BI0100001149 60 mtrs
37 37 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm BI01010001010000000000000515BI0100001150 5 mtrs
38 38 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm BI01010001010000000000000515BI0100001151 5 mtrs
39 39 Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. BI01010001010000000000000515BI0100001152 9 each
40 40 Supplying,Installation, testing and commissioning of 1200 MM Sweep Energy saving 5 star rating ceiling fan three blades but without regulator including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable i/c fan hook of Havells Make of PACER Model complete etc as reqd.Havells/Bajaj/CG/ make of havells -pacer base model/CG-HS-PLUS-5 STAR 1200MM OPAL WHITE/BAJAJ-AKIK 1200 MM AZOTIC TOPAZ CF PRIMIUM FAN BI01010001010000000000000515BI0100001153 24 Each
41 41 Supplying installation testing and commissioning of fresh air Exaust fan (Metal body) 300/305 mm size Heavy Duty of Havells Make with self opening louvers in the existing wall with suitable size PVC connectors for making connections i/c to suitable size of fan and making good the damage complete and louver shuters etc as required.Havells/CG/Bajaj make. BI01010001010000000000000515BI0100001154 9 Each
42 42 Providing and fixing of 10 W LED battern for mirror light new e-Lite LeD triyca batten with options of 3000K , all in one fixture Havella make with wire complete with connection, testing commissioning etc as required and similiar Make of CG/Bajaj/Havells/Philips of Havells -LHEXBXDNINILW010 BI01010001010000000000000515BI0100001155 4 each
43 43 Providing and fixing of 18 W LED BoLt square/round(ceiling light) Havella make with wire complete with connection, testing commissioning etc as required. Make CG/Bajaj/Havells/Philips of CG LCDSPLN - S-L8-CDL /HAVELLS -LHEAAWP7LJW018 /PHILLIPS-DN096B-LED 10S 6500 PSU WH BI01010001010000000000000515BI0100001156 59 each
44 44 Providing and fixing of 20 LED batten E-LItE LED CurvE havells make with wire complete with connection, testing commissioning etc as required. Make CG/Bajaj/Havells/Philips of CG LSD- 20-CDL /HAVELLS -LHEX13XPNIJN1W020 /BAJAJ- LEDLUBCLGH /PHILLIPS -BN027CLED-20 SPSU-NUK BI01010001010000000000000515BI0100001157 2 each
45 45 Supplying and fixing wall mounted bed light LED fitting i/c LED Lamp with wire complete with connection, testing commissioning etc as required of ISI Mark only BI01010001010000000000000515BI0100001157 20 Each
46 46 Providing and fixing of 45 watt LED street light LED OF 5700 K made up of pressure die cast housing with toughned glass and individual high power LEDs of havells make with inbuilt LED light source, 32 mm dia X 2 Mtr long GI pipe brakcet for mounting on the wall including bending the pipe to the required shape, flat iron clamps with nut, bolts and washers including painting with connection, testing commissioning etc as required. Make CG/Bajaj/Havells/Philips of CG LSTB-45-CDL /BAJAJ -BRTFG 45W LEDWW BI01010001010000000000000515BI0100001158 8 Each
47 47 Providing and fixing of electric storage water heater of 25 ltr of 2 KW of havells make i/c fasteners with nut, bolts and washers including with connection, testing commissioning etc as required and similar specifications of CG/Bajaj BI01010001010000000000000515BI0100001159 9 Each
48 48 Supplying & laying of one number PVC insulated and PVC sheathed Armoured / XLPE power cable of 1.1 KV grade of size 2 x 10 sqmm, direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering Conf. to IS:7098 part - I of make Havells / Polycab / finolex / Gloster for DB box of building & Post top lantern BI01010001010000000000000515BI0100001160 135 mtrs
49 49 Supplying & laying of one number PVC insulated and PVC sheathed / XPLE power cable of 1.1 KV grade of size 2 x 10 sqmm. in the existng RCC / HUME / METAL pipe as required Conf. to IS:7098 part - I of make Havells / Polycab / finolex / Gloster for DB box of building & Post top lantern BI01010001010000000000000515BI0100001161 35 mtrs
50 50 Supplying & laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size 2 x 10 sqmm. in the existing masonry open duct as required. Conf. to IS:7098 part - I of make Havells / Polycab / finolex / Gloster for DB box of building & Post top lantern BI01010001010000000000000515BI0100001162 6 mtrs
51 51 Providing and fixing of decorative crown shaped post top lantern of size of 60 mm dia for mounting on GI Pole of unbreakable Polycarbonate made suitable for retrofit CFL/LED (B-22 base) upto 27 watt of havells make of model code LHDC11126099 & HSN Code 9405 incluiding 20 Watt LED lamp of havells make and similiar specification of BAJAJ/CG/Philips, with loop box with transparent lid of Hensel make inculiding of single pole 6 Amp B series MCB of Havells make and similiar specification of Sintex/L&T/C&S/HPL/Legrand, with 3 mtr GI Pole/Pipe of 65 mm dia(2.5 inch) Heavy duty(C Class) with suitable reducer 65 mm to 60 mm and similiar specifiaction of hindustan/praksh/tata/Ravindra with single coat of red oxcide paint & two coat paint aluminium paint on pole before insttalation with nut, bolts and washers including with electrical connection with 1.5 sqmm FRLS copper wire from post top lamp to Loop box incluiding excavation including refilling as required upto 1 mtr depth for insttalation of 65 mm GI Pole with Cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) for insttalation & making of collar of 65 mm GI Pole and testing commissioning etc as required (Final approval issued by Engineer in Charge) BI01010001010000000000000515BI0100001163 8 Each