Indian Navy-IN has published Repair Rate Contract For Starter , Hcos And Acos Onboard Eastern Naval Command Ships. Submission Date for this Tender is 11-11-2019. Screws Tenders in FLEET MAINTENANCE UNTI VISAKHAPATNAM Andhra Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: RRC FOR REPAIR OF STARTERS, HCOS AND ACOS FOR ENC SHIPS | |||||
---|---|---|---|---|---|
Sl. No. | Description of Service / Spare | HSN / SAC Code | QTY | Units | |
1 | 1 | FIRST YEAR | |||
2 | 2 | SERVICES | |||
3 | 3 | 5A | |||
4 | 3.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
5 | 3.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
6 | 3.03 | Calibration of O/L Relay | 1 | Nos | |
7 | 3.04 | Repair of Coils | 1 | Nos | |
8 | 3.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
9 | 3.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
10 | 3.07 | Replacement of Push Button switches | 1 | Nos | |
11 | 3.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
12 | 3.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
13 | 3.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
14 | 3.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
15 | 3.12 | Repair of Control Transformers | 1 | Nos | |
16 | 3.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
17 | 3.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
18 | 3.15 | Replacement of Control Fuses | 1 | Nos | |
19 | 3.16 | Replacement of time delay relay | 1 | Nos | |
20 | 3.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
21 | 3.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
22 | 3.19 | Replacement of Rotary Switches | 1 | Nos | |
23 | 3.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
24 | 3.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
25 | 3.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
26 | 3.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
27 | 3.24 | Replacement of Lock Pins | 1 | Nos | |
28 | 3.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
29 | 3.26 | Replacement of Ebonite Board | 1 | Nos | |
30 | 3.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
31 | 3.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
32 | 3.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
33 | 3.3 | Replacement of Change Over Handle | 1 | Nos | |
34 | 3.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
35 | 3.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
36 | 3.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
37 | 3.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
38 | 3.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
39 | 3.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
40 | 3.37 | Repair of Amp/Volt Meter | 1 | Nos | |
41 | 3.38 | Painting | 1 | Nos | |
42 | 3.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
43 | 3.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
44 | 3.41 | Repair of Electronic Protection Unit | 1 | Nos | |
45 | 3.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
46 | 3.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
47 | 3.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
48 | 3.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
49 | 3.46 | Replacement of MCCB | 1 | Nos | |
50 | 3.47 | Replacement of Power Diode | 1 | Nos | |
51 | 3.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
52 | 3.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
53 | 3.5 | Replacement of Overload Relay | 1 | Nos | |
54 | 3.51 | Replacement of Coils | 1 | Nos | |
55 | 3.52 | Replacement of Voltage Relays | 1 | Nos | |
56 | 3.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
57 | 3.54 | Renewal of 3 Core Cable | 1 | Nos | |
58 | 3.55 | Replacement of Control Transformers | 1 | Nos | |
59 | 3.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
60 | 3.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
61 | 3.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
62 | 3.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
63 | 3.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
64 | 3.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
65 | 3.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
66 | 3.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
67 | 3.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
68 | 3.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
69 | 4 | 5.1-10A | |||
70 | 4.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
71 | 4.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
72 | 4.03 | Calibration of O/L Relay | 1 | Nos | |
73 | 4.04 | Repair of Coils | 1 | Nos | |
74 | 4.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
75 | 4.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
76 | 4.07 | Replacement of Push Button switches | 1 | Nos | |
77 | 4.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 7 | Nos | |
78 | 4.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
79 | 4.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
80 | 4.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
81 | 4.12 | Repair of Control Transformers | 1 | Nos | |
82 | 4.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
83 | 4.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
84 | 4.15 | Replacement of Control Fuses | 13 | Nos | |
85 | 4.16 | Replacement of time delay relay | 1 | Nos | |
86 | 4.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
87 | 4.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
88 | 4.19 | Replacement of Rotary Switches | 1 | Nos | |
89 | 4.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
90 | 4.21 | Replacement of Bakelite Moulding Rate/MM | 10 | Nos | |
91 | 4.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
92 | 4.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
93 | 4.24 | Replacement of Lock Pins | 1 | Nos | |
94 | 4.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
95 | 4.26 | Replacement of Ebonite Board | 1 | Nos | |
96 | 4.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
97 | 4.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
98 | 4.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
99 | 4.3 | Replacement of Change Over Handle | 1 | Nos | |
100 | 4.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
101 | 4.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
102 | 4.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
103 | 4.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
104 | 4.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
105 | 4.36 | Replacement of NO/NC Auxiliary Contacts | 2 | Nos | |
106 | 4.37 | Repair of Amp/Volt Meter | 1 | Nos | |
107 | 4.38 | Painting | 1 | Nos | |
108 | 4.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
109 | 4.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
110 | 4.41 | Repair of Electronic Protection Unit | 2 | Nos | |
111 | 4.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
112 | 4.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
113 | 4.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
114 | 4.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
115 | 4.46 | Replacement of MCCB | 1 | Nos | |
116 | 4.47 | Replacement of Power Diode | 1 | Nos | |
117 | 4.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
118 | 4.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
119 | 4.5 | Replacement of Overload Relay | 6 | Nos | |
120 | 4.51 | Replacement of Coils | 1 | Nos | |
121 | 4.52 | Replacement of Voltage Relays | 1 | Nos | |
122 | 4.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
123 | 4.54 | Renewal of 3 Core Cable | 1 | Nos | |
124 | 4.55 | Replacement of Control Transformers | 1 | Nos | |
125 | 4.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
126 | 4.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
127 | 4.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
128 | 4.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
129 | 4.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
130 | 4.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
131 | 4.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
132 | 4.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
133 | 4.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
134 | 4.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
135 | 5 | 10.1-15A | |||
136 | 5.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 58 | Nos | |
137 | 5.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
138 | 5.03 | Calibration of O/L Relay | 1 | Nos | |
139 | 5.04 | Repair of Coils | 1 | Nos | |
140 | 5.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 7 | Nos | |
141 | 5.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 47 | Nos | |
142 | 5.07 | Replacement of Push Button switches | 1 | Nos | |
143 | 5.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 38 | Nos | |
144 | 5.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 5 | Nos | |
145 | 5.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
146 | 5.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
147 | 5.12 | Repair of Control Transformers | 2 | Nos | |
148 | 5.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
149 | 5.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
150 | 5.15 | Replacement of Control Fuses | 99 | Nos | |
151 | 5.16 | Replacement of time delay relay | 6 | Nos | |
152 | 5.17 | Replacement of Indication Lamps and Holders | 6 | Nos | |
153 | 5.18 | Replacement of ON/OFF Push Units | 2 | Nos | |
154 | 5.19 | Replacement of Rotary Switches | 1 | Nos | |
155 | 5.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
156 | 5.21 | Replacement of Bakelite Moulding Rate/MM | 7 | Nos | |
157 | 5.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
158 | 5.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
159 | 5.24 | Replacement of Lock Pins | 1 | Nos | |
160 | 5.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
161 | 5.26 | Replacement of Ebonite Board | 1 | Nos | |
162 | 5.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
163 | 5.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
164 | 5.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
165 | 5.3 | Replacement of Change Over Handle | 1 | Nos | |
166 | 5.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
167 | 5.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
168 | 5.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
169 | 5.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
170 | 5.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
171 | 5.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
172 | 5.37 | Repair of Amp/Volt Meter | 1 | Nos | |
173 | 5.38 | Painting | 1 | Nos | |
174 | 5.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
175 | 5.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
176 | 5.41 | Repair of Electronic Protection Unit | 5 | Nos | |
177 | 5.42 | Replacement of Electronic Protection Unit | 26 | Nos | |
178 | 5.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
179 | 5.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
180 | 5.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
181 | 5.46 | Replacement of MCCB | 1 | Nos | |
182 | 5.47 | Replacement of Power Diode | 1 | Nos | |
183 | 5.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
184 | 5.49 | Replacement of Socket (Brass & Ebonite) | 2 | Nos | |
185 | 5.5 | Replacement of Overload Relay | 53 | Nos | |
186 | 5.51 | Replacement of Coils | 3 | Nos | |
187 | 5.52 | Replacement of Voltage Relays | 2 | Nos | |
188 | 5.53 | Replacement of ON/OFF Stage Over Switch | 21 | Nos | |
189 | 5.54 | Renewal of 3 Core Cable | 1 | Nos | |
190 | 5.55 | Replacement of Control Transformers | 1 | Nos | |
191 | 5.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
192 | 5.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
193 | 5.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
194 | 5.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
195 | 5.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
196 | 5.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
197 | 5.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
198 | 5.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
199 | 5.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
200 | 5.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
201 | 6 | 15.1-20A | |||
202 | 6.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 14 | Nos | |
203 | 6.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
204 | 6.03 | Calibration of O/L Relay | 1 | Nos | |
205 | 6.04 | Repair of Coils | 1 | Nos | |
206 | 6.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
207 | 6.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 11 | Nos | |
208 | 6.07 | Replacement of Push Button switches | 1 | Nos | |
209 | 6.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 3 | Nos | |
210 | 6.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
211 | 6.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
212 | 6.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
213 | 6.12 | Repair of Control Transformers | 1 | Nos | |
214 | 6.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 2 | Nos | |
215 | 6.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
216 | 6.15 | Replacement of Control Fuses | 25 | Nos | |
217 | 6.16 | Replacement of time delay relay | 4 | Nos | |
218 | 6.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
219 | 6.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
220 | 6.19 | Replacement of Rotary Switches | 1 | Nos | |
221 | 6.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
222 | 6.21 | Replacement of Bakelite Moulding Rate/MM | 8 | Nos | |
223 | 6.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
224 | 6.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
225 | 6.24 | Replacement of Lock Pins | 1 | Nos | |
226 | 6.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
227 | 6.26 | Replacement of Ebonite Board | 1 | Nos | |
228 | 6.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
229 | 6.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
230 | 6.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
231 | 6.3 | Replacement of Change Over Handle | 1 | Nos | |
232 | 6.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
233 | 6.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
234 | 6.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
235 | 6.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
236 | 6.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
237 | 6.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
238 | 6.37 | Repair of Amp/Volt Meter | 1 | Nos | |
239 | 6.38 | Painting | 2 | Nos | |
240 | 6.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
241 | 6.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
242 | 6.41 | Repair of Electronic Protection Unit | 2 | Nos | |
243 | 6.42 | Replacement of Electronic Protection Unit | 5 | Nos | |
244 | 6.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
245 | 6.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
246 | 6.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
247 | 6.46 | Replacement of MCCB | 1 | Nos | |
248 | 6.47 | Replacement of Power Diode | 1 | Nos | |
249 | 6.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
250 | 6.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
251 | 6.5 | Replacement of Overload Relay | 12 | Nos | |
252 | 6.51 | Replacement of Coils | 1 | Nos | |
253 | 6.52 | Replacement of Voltage Relays | 1 | Nos | |
254 | 6.53 | Replacement of ON/OFF Stage Over Switch | 8 | Nos | |
255 | 6.54 | Renewal of 3 Core Cable | 1 | Nos | |
256 | 6.55 | Replacement of Control Transformers | 1 | Nos | |
257 | 6.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
258 | 6.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
259 | 6.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
260 | 6.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
261 | 6.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
262 | 6.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
263 | 6.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
264 | 6.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
265 | 6.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
266 | 6.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
267 | 7 | 20.1-30A | |||
268 | 7.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 2 | Nos | |
269 | 7.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
270 | 7.03 | Calibration of O/L Relay | 1 | Nos | |
271 | 7.04 | Repair of Coils | 1 | Nos | |
272 | 7.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
273 | 7.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
274 | 7.07 | Replacement of Push Button switches | 1 | Nos | |
275 | 7.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 5 | Nos | |
276 | 7.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
277 | 7.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
278 | 7.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
279 | 7.12 | Repair of Control Transformers | 1 | Nos | |
280 | 7.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
281 | 7.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
282 | 7.15 | Replacement of Control Fuses | 2 | Nos | |
283 | 7.16 | Replacement of time delay relay | 1 | Nos | |
284 | 7.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
285 | 7.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
286 | 7.19 | Replacement of Rotary Switches | 1 | Nos | |
287 | 7.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
288 | 7.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
289 | 7.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 2 | Nos | |
290 | 7.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
291 | 7.24 | Replacement of Lock Pins | 1 | Nos | |
292 | 7.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
293 | 7.26 | Replacement of Ebonite Board | 1 | Nos | |
294 | 7.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
295 | 7.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
296 | 7.29 | Replacement of Wire Wound Resistors | 2 | Nos | |
297 | 7.3 | Replacement of Change Over Handle | 1 | Nos | |
298 | 7.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
299 | 7.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
300 | 7.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
301 | 7.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
302 | 7.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
303 | 7.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
304 | 7.37 | Repair of Amp/Volt Meter | 1 | Nos | |
305 | 7.38 | Painting | 1 | Nos | |
306 | 7.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
307 | 7.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
308 | 7.41 | Repair of Electronic Protection Unit | 1 | Nos | |
309 | 7.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
310 | 7.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
311 | 7.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
312 | 7.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
313 | 7.46 | Replacement of MCCB | 1 | Nos | |
314 | 7.47 | Replacement of Power Diode | 1 | Nos | |
315 | 7.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
316 | 7.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
317 | 7.5 | Replacement of Overload Relay | 2 | Nos | |
318 | 7.51 | Replacement of Coils | 1 | Nos | |
319 | 7.52 | Replacement of Voltage Relays | 1 | Nos | |
320 | 7.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
321 | 7.54 | Renewal of 3 Core Cable | 1 | Nos | |
322 | 7.55 | Replacement of Control Transformers | 1 | Nos | |
323 | 7.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
324 | 7.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
325 | 7.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
326 | 7.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
327 | 7.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
328 | 7.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
329 | 7.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
330 | 7.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
331 | 7.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
332 | 7.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
333 | 8 | 30.1-50A | |||
334 | 8.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 8 | Nos | |
335 | 8.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
336 | 8.03 | Calibration of O/L Relay | 1 | Nos | |
337 | 8.04 | Repair of Coils | 1 | Nos | |
338 | 8.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 3 | Nos | |
339 | 8.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
340 | 8.07 | Replacement of Push Button switches | 1 | Nos | |
341 | 8.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 15 | Nos | |
342 | 8.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
343 | 8.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
344 | 8.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
345 | 8.12 | Repair of Control Transformers | 1 | Nos | |
346 | 8.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
347 | 8.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
348 | 8.15 | Replacement of Control Fuses | 14 | Nos | |
349 | 8.16 | Replacement of time delay relay | 3 | Nos | |
350 | 8.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
351 | 8.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
352 | 8.19 | Replacement of Rotary Switches | 1 | Nos | |
353 | 8.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
354 | 8.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
355 | 8.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 24 | Nos | |
356 | 8.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
357 | 8.24 | Replacement of Lock Pins | 1 | Nos | |
358 | 8.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
359 | 8.26 | Replacement of Ebonite Board | 1 | Nos | |
360 | 8.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
361 | 8.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
362 | 8.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
363 | 8.3 | Replacement of Change Over Handle | 1 | Nos | |
364 | 8.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
365 | 8.32 | Repair of 3 Ph 4 Way Rotary Switch | 4 | Nos | |
366 | 8.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
367 | 8.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
368 | 8.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
369 | 8.36 | Replacement of NO/NC Auxiliary Contacts | 7 | Nos | |
370 | 8.37 | Repair of Amp/Volt Meter | 1 | Nos | |
371 | 8.38 | Painting | 1 | Nos | |
372 | 8.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
373 | 8.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
374 | 8.41 | Repair of Electronic Protection Unit | 2 | Nos | |
375 | 8.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
376 | 8.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
377 | 8.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
378 | 8.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
379 | 8.46 | Replacement of MCCB | 1 | Nos | |
380 | 8.47 | Replacement of Power Diode | 20 | Nos | |
381 | 8.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
382 | 8.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
383 | 8.5 | Replacement of Overload Relay | 2 | Nos | |
384 | 8.51 | Replacement of Coils | 3 | Nos | |
385 | 8.52 | Replacement of Voltage Relays | 6 | Nos | |
386 | 8.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
387 | 8.54 | Renewal of 3 Core Cable | 1 | Nos | |
388 | 8.55 | Replacement of Control Transformers | 1 | Nos | |
389 | 8.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
390 | 8.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
391 | 8.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
392 | 8.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
393 | 8.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
394 | 8.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
395 | 8.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
396 | 8.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
397 | 8.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 6 | Nos | |
398 | 8.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
399 | 9 | 50.1-75A | |||
400 | 9.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 7 | Nos | |
401 | 9.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
402 | 9.03 | Calibration of O/L Relay | 1 | Nos | |
403 | 9.04 | Repair of Coils | 1 | Nos | |
404 | 9.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
405 | 9.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 4 | Nos | |
406 | 9.07 | Replacement of Push Button switches | 1 | Nos | |
407 | 9.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 40 | Nos | |
408 | 9.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
409 | 9.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
410 | 9.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
411 | 9.12 | Repair of Control Transformers | 1 | Nos | |
412 | 9.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
413 | 9.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
414 | 9.15 | Replacement of Control Fuses | 20 | Nos | |
415 | 9.16 | Replacement of time delay relay | 1 | Nos | |
416 | 9.17 | Replacement of Indication Lamps and Holders | 3 | Nos | |
417 | 9.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
418 | 9.19 | Replacement of Rotary Switches | 1 | Nos | |
419 | 9.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
420 | 9.21 | Replacement of Bakelite Moulding Rate/MM | 9 | Nos | |
421 | 9.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 18 | Nos | |
422 | 9.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
423 | 9.24 | Replacement of Lock Pins | 1 | Nos | |
424 | 9.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
425 | 9.26 | Replacement of Ebonite Board | 1 | Nos | |
426 | 9.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
427 | 9.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
428 | 9.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
429 | 9.3 | Replacement of Change Over Handle | 1 | Nos | |
430 | 9.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
431 | 9.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
432 | 9.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
433 | 9.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
434 | 9.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
435 | 9.36 | Replacement of NO/NC Auxiliary Contacts | 13 | Nos | |
436 | 9.37 | Repair of Amp/Volt Meter | 1 | Nos | |
437 | 9.38 | Painting | 1 | Nos | |
438 | 9.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
439 | 9.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
440 | 9.41 | Repair of Electronic Protection Unit | 3 | Nos | |
441 | 9.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
442 | 9.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
443 | 9.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
444 | 9.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
445 | 9.46 | Replacement of MCCB | 1 | Nos | |
446 | 9.47 | Replacement of Power Diode | 5 | Nos | |
447 | 9.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
448 | 9.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
449 | 9.5 | Replacement of Overload Relay | 1 | Nos | |
450 | 9.51 | Replacement of Coils | 1 | Nos | |
451 | 9.52 | Replacement of Voltage Relays | 3 | Nos | |
452 | 9.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
453 | 9.54 | Renewal of 3 Core Cable | 1 | Nos | |
454 | 9.55 | Replacement of Control Transformers | 1 | Nos | |
455 | 9.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
456 | 9.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
457 | 9.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
458 | 9.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
459 | 9.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
460 | 9.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
461 | 9.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
462 | 9.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
463 | 9.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
464 | 9.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
465 | 10 | 75.1-100A | |||
466 | 10.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 9 | Nos | |
467 | 10.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
468 | 10.03 | Calibration of O/L Relay | 1 | Nos | |
469 | 10.04 | Repair of Coils | 1 | Nos | |
470 | 10.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 4 | Nos | |
471 | 10.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
472 | 10.07 | Replacement of Push Button switches | 1 | Nos | |
473 | 10.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 25 | Nos | |
474 | 10.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
475 | 10.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
476 | 10.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
477 | 10.12 | Repair of Control Transformers | 1 | Nos | |
478 | 10.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
479 | 10.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
480 | 10.15 | Replacement of Control Fuses | 17 | Nos | |
481 | 10.16 | Replacement of time delay relay | 4 | Nos | |
482 | 10.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
483 | 10.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
484 | 10.19 | Replacement of Rotary Switches | 1 | Nos | |
485 | 10.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
486 | 10.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
487 | 10.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 27 | Nos | |
488 | 10.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
489 | 10.24 | Replacement of Lock Pins | 1 | Nos | |
490 | 10.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
491 | 10.26 | Replacement of Ebonite Board | 1 | Nos | |
492 | 10.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 9 | Nos | |
493 | 10.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
494 | 10.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
495 | 10.3 | Replacement of Change Over Handle | 1 | Nos | |
496 | 10.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
497 | 10.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
498 | 10.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
499 | 10.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
500 | 10.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
501 | 10.36 | Replacement of NO/NC Auxiliary Contacts | 10 | Nos | |
502 | 10.37 | Repair of Amp/Volt Meter | 2 | Nos | |
503 | 10.38 | Painting | 1 | Nos | |
504 | 10.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
505 | 10.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
506 | 10.41 | Repair of Electronic Protection Unit | 1 | Nos | |
507 | 10.42 | Replacement of Electronic Protection Unit | 2 | Nos | |
508 | 10.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
509 | 10.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
510 | 10.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
511 | 10.46 | Replacement of MCCB | 1 | Nos | |
512 | 10.47 | Replacement of Power Diode | 18 | Nos | |
513 | 10.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
514 | 10.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
515 | 10.5 | Replacement of Overload Relay | 3 | Nos | |
516 | 10.51 | Replacement of Coils | 3 | Nos | |
517 | 10.52 | Replacement of Voltage Relays | 6 | Nos | |
518 | 10.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
519 | 10.54 | Renewal of 3 Core Cable | 1 | Nos | |
520 | 10.55 | Replacement of Control Transformers | 1 | Nos | |
521 | 10.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
522 | 10.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
523 | 10.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
524 | 10.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
525 | 10.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
526 | 10.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
527 | 10.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
528 | 10.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
529 | 10.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
530 | 10.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 3 | Nos | |
531 | 11 | 100.1-150A | |||
532 | 11.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 21 | Nos | |
533 | 11.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
534 | 11.03 | Calibration of O/L Relay | 1 | Nos | |
535 | 11.04 | Repair of Coils | 1 | Nos | |
536 | 11.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 5 | Nos | |
537 | 11.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
538 | 11.07 | Replacement of Push Button switches | 1 | Nos | |
539 | 11.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 79 | Nos | |
540 | 11.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
541 | 11.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 2 | Nos | |
542 | 11.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
543 | 11.12 | Repair of Control Transformers | 1 | Nos | |
544 | 11.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
545 | 11.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
546 | 11.15 | Replacement of Control Fuses | 43 | Nos | |
547 | 11.16 | Replacement of time delay relay | 16 | Nos | |
548 | 11.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
549 | 11.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
550 | 11.19 | Replacement of Rotary Switches | 1 | Nos | |
551 | 11.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
552 | 11.21 | Replacement of Bakelite Moulding Rate/MM | 15 | Nos | |
553 | 11.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 61 | Nos | |
554 | 11.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 4 | Nos | |
555 | 11.24 | Replacement of Lock Pins | 1 | Nos | |
556 | 11.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
557 | 11.26 | Replacement of Ebonite Board | 1 | Nos | |
558 | 11.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 10 | Nos | |
559 | 11.28 | Replacement of Bakelite Switches and Knobs | 2 | Nos | |
560 | 11.29 | Replacement of Wire Wound Resistors | 67 | Nos | |
561 | 11.3 | Replacement of Change Over Handle | 1 | Nos | |
562 | 11.31 | Repair of Single Phase Protection Unit | 3 | Nos | |
563 | 11.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
564 | 11.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
565 | 11.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
566 | 11.35 | Replacement of Rubber Beading of Starter (Gasket) | 2 | Nos | |
567 | 11.36 | Replacement of NO/NC Auxiliary Contacts | 51 | Nos | |
568 | 11.37 | Repair of Amp/Volt Meter | 1 | Nos | |
569 | 11.38 | Painting | 1 | Nos | |
570 | 11.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
571 | 11.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
572 | 11.41 | Repair of Electronic Protection Unit | 1 | Nos | |
573 | 11.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
574 | 11.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
575 | 11.44 | Replacement of TPU (Thermal Power Unit) | 4 | Nos | |
576 | 11.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 12 | Nos | |
577 | 11.46 | Replacement of MCCB | 1 | Nos | |
578 | 11.47 | Replacement of Power Diode | 94 | Nos | |
579 | 11.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 3 | Nos | |
580 | 11.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
581 | 11.5 | Replacement of Overload Relay | 4 | Nos | |
582 | 11.51 | Replacement of Coils | 9 | Nos | |
583 | 11.52 | Replacement of Voltage Relays | 9 | Nos | |
584 | 11.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
585 | 11.54 | Renewal of 3 Core Cable | 1 | Nos | |
586 | 11.55 | Replacement of Control Transformers | 1 | Nos | |
587 | 11.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
588 | 11.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
589 | 11.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
590 | 11.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
591 | 11.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
592 | 11.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
593 | 11.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
594 | 11.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
595 | 11.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 9 | Nos | |
596 | 11.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 4 | Nos | |
597 | 12 | 150.1-200A | |||
598 | 12.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
599 | 12.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
600 | 12.03 | Calibration of O/L Relay | 1 | Nos | |
601 | 12.04 | Repair of Coils | 1 | Nos | |
602 | 12.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
603 | 12.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
604 | 12.07 | Replacement of Push Button switches | 1 | Nos | |
605 | 12.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 10 | Nos | |
606 | 12.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
607 | 12.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
608 | 12.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
609 | 12.12 | Repair of Control Transformers | 1 | Nos | |
610 | 12.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
611 | 12.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
612 | 12.15 | Replacement of Control Fuses | 6 | Nos | |
613 | 12.16 | Replacement of time delay relay | 3 | Nos | |
614 | 12.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
615 | 12.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
616 | 12.19 | Replacement of Rotary Switches | 1 | Nos | |
617 | 12.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
618 | 12.21 | Replacement of Bakelite Moulding Rate/MM | 2 | Nos | |
619 | 12.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 21 | Nos | |
620 | 12.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
621 | 12.24 | Replacement of Lock Pins | 1 | Nos | |
622 | 12.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
623 | 12.26 | Replacement of Ebonite Board | 1 | Nos | |
624 | 12.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
625 | 12.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
626 | 12.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
627 | 12.3 | Replacement of Change Over Handle | 1 | Nos | |
628 | 12.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
629 | 12.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
630 | 12.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
631 | 12.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
632 | 12.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
633 | 12.36 | Replacement of NO/NC Auxiliary Contacts | 6 | Nos | |
634 | 12.37 | Repair of Amp/Volt Meter | 1 | Nos | |
635 | 12.38 | Painting | 1 | Nos | |
636 | 12.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
637 | 12.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
638 | 12.41 | Repair of Electronic Protection Unit | 1 | Nos | |
639 | 12.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
640 | 12.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
641 | 12.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
642 | 12.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 2 | Nos | |
643 | 12.46 | Replacement of MCCB | 1 | Nos | |
644 | 12.47 | Replacement of Power Diode | 4 | Nos | |
645 | 12.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
646 | 12.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
647 | 12.5 | Replacement of Overload Relay | 1 | Nos | |
648 | 12.51 | Replacement of Coils | 1 | Nos | |
649 | 12.52 | Replacement of Voltage Relays | 3 | Nos | |
650 | 12.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
651 | 12.54 | Renewal of 3 Core Cable | 1 | Nos | |
652 | 12.55 | Replacement of Control Transformers | 1 | Nos | |
653 | 12.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
654 | 12.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
655 | 12.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
656 | 12.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
657 | 12.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
658 | 12.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
659 | 12.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
660 | 12.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
661 | 12.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 2 | Nos | |
662 | 12.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
663 | 13 | 200.1-300A | |||
664 | 13.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
665 | 13.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
666 | 13.03 | Calibration of O/L Relay | 1 | Nos | |
667 | 13.04 | Repair of Coils | 1 | Nos | |
668 | 13.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
669 | 13.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
670 | 13.07 | Replacement of Push Button switches | 1 | Nos | |
671 | 13.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 17 | Nos | |
672 | 13.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
673 | 13.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
674 | 13.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
675 | 13.12 | Repair of Control Transformers | 1 | Nos | |
676 | 13.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
677 | 13.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
678 | 13.15 | Replacement of Control Fuses | 7 | Nos | |
679 | 13.16 | Replacement of time delay relay | 3 | Nos | |
680 | 13.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
681 | 13.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
682 | 13.19 | Replacement of Rotary Switches | 1 | Nos | |
683 | 13.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
684 | 13.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
685 | 13.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 17 | Nos | |
686 | 13.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
687 | 13.24 | Replacement of Lock Pins | 1 | Nos | |
688 | 13.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
689 | 13.26 | Replacement of Ebonite Board | 1 | Nos | |
690 | 13.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
691 | 13.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
692 | 13.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
693 | 13.3 | Replacement of Change Over Handle | 1 | Nos | |
694 | 13.31 | Repair of Single Phase Protection Unit | 2 | Nos | |
695 | 13.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
696 | 13.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
697 | 13.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
698 | 13.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
699 | 13.36 | Replacement of NO/NC Auxiliary Contacts | 11 | Nos | |
700 | 13.37 | Repair of Amp/Volt Meter | 1 | Nos | |
701 | 13.38 | Painting | 1 | Nos | |
702 | 13.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
703 | 13.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
704 | 13.41 | Repair of Electronic Protection Unit | 1 | Nos | |
705 | 13.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
706 | 13.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
707 | 13.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
708 | 13.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
709 | 13.46 | Replacement of MCCB | 1 | Nos | |
710 | 13.47 | Replacement of Power Diode | 4 | Nos | |
711 | 13.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
712 | 13.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
713 | 13.5 | Replacement of Overload Relay | 1 | Nos | |
714 | 13.51 | Replacement of Coils | 1 | Nos | |
715 | 13.52 | Replacement of Voltage Relays | 5 | Nos | |
716 | 13.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
717 | 13.54 | Renewal of 3 Core Cable | 1 | Nos | |
718 | 13.55 | Replacement of Control Transformers | 1 | Nos | |
719 | 13.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
720 | 13.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
721 | 13.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
722 | 13.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
723 | 13.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
724 | 13.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
725 | 13.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
726 | 13.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
727 | 13.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
728 | 13.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
729 | 14 | 300.1-500A | |||
730 | 14.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
731 | 14.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
732 | 14.03 | Calibration of O/L Relay | 1 | Nos | |
733 | 14.04 | Repair of Coils | 1 | Nos | |
734 | 14.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
735 | 14.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
736 | 14.07 | Replacement of Push Button switches | 1 | Nos | |
737 | 14.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
738 | 14.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
739 | 14.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
740 | 14.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
741 | 14.12 | Repair of Control Transformers | 1 | Nos | |
742 | 14.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
743 | 14.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
744 | 14.15 | Replacement of Control Fuses | 1 | Nos | |
745 | 14.16 | Replacement of time delay relay | 1 | Nos | |
746 | 14.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
747 | 14.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
748 | 14.19 | Replacement of Rotary Switches | 1 | Nos | |
749 | 14.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
750 | 14.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
751 | 14.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 40 | Nos | |
752 | 14.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
753 | 14.24 | Replacement of Lock Pins | 1 | Nos | |
754 | 14.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
755 | 14.26 | Replacement of Ebonite Board | 1 | Nos | |
756 | 14.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
757 | 14.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
758 | 14.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
759 | 14.3 | Replacement of Change Over Handle | 1 | Nos | |
760 | 14.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
761 | 14.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
762 | 14.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
763 | 14.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
764 | 14.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
765 | 14.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
766 | 14.37 | Repair of Amp/Volt Meter | 1 | Nos | |
767 | 14.38 | Painting | 1 | Nos | |
768 | 14.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
769 | 14.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
770 | 14.41 | Repair of Electronic Protection Unit | 1 | Nos | |
771 | 14.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
772 | 14.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
773 | 14.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
774 | 14.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
775 | 14.46 | Replacement of MCCB | 1 | Nos | |
776 | 14.47 | Replacement of Power Diode | 1 | Nos | |
777 | 14.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
778 | 14.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
779 | 14.5 | Replacement of Overload Relay | 1 | Nos | |
780 | 14.51 | Replacement of Coils | 1 | Nos | |
781 | 14.52 | Replacement of Voltage Relays | 1 | Nos | |
782 | 14.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
783 | 14.54 | Renewal of 3 Core Cable | 1 | Nos | |
784 | 14.55 | Replacement of Control Transformers | 1 | Nos | |
785 | 14.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
786 | 14.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
787 | 14.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
788 | 14.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
789 | 14.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
790 | 14.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
791 | 14.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
792 | 14.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
793 | 14.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
794 | 14.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
795 | 15 | 500.1-600A | |||
796 | 15.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
797 | 15.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
798 | 15.03 | Calibration of O/L Relay | 1 | Nos | |
799 | 15.04 | Repair of Coils | 1 | Nos | |
800 | 15.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
801 | 15.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
802 | 15.07 | Replacement of Push Button switches | 1 | Nos | |
803 | 15.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
804 | 15.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
805 | 15.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
806 | 15.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
807 | 15.12 | Repair of Control Transformers | 1 | Nos | |
808 | 15.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
809 | 15.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
810 | 15.15 | Replacement of Control Fuses | 1 | Nos | |
811 | 15.16 | Replacement of time delay relay | 1 | Nos | |
812 | 15.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
813 | 15.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
814 | 15.19 | Replacement of Rotary Switches | 1 | Nos | |
815 | 15.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
816 | 15.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
817 | 15.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 3 | Nos | |
818 | 15.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
819 | 15.24 | Replacement of Lock Pins | 1 | Nos | |
820 | 15.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
821 | 15.26 | Replacement of Ebonite Board | 1 | Nos | |
822 | 15.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
823 | 15.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
824 | 15.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
825 | 15.3 | Replacement of Change Over Handle | 1 | Nos | |
826 | 15.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
827 | 15.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
828 | 15.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
829 | 15.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
830 | 15.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
831 | 15.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
832 | 15.37 | Repair of Amp/Volt Meter | 1 | Nos | |
833 | 15.38 | Painting | 1 | Nos | |
834 | 15.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
835 | 15.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
836 | 15.41 | Repair of Electronic Protection Unit | 1 | Nos | |
837 | 15.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
838 | 15.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
839 | 15.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
840 | 15.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
841 | 15.46 | Replacement of MCCB | 1 | Nos | |
842 | 15.47 | Replacement of Power Diode | 1 | Nos | |
843 | 15.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
844 | 15.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
845 | 15.5 | Replacement of Overload Relay | 1 | Nos | |
846 | 15.51 | Replacement of Coils | 1 | Nos | |
847 | 15.52 | Replacement of Voltage Relays | 1 | Nos | |
848 | 15.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
849 | 15.54 | Renewal of 3 Core Cable | 1 | Nos | |
850 | 15.55 | Replacement of Control Transformers | 1 | Nos | |
851 | 15.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
852 | 15.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
853 | 15.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
854 | 15.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
855 | 15.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
856 | 15.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
857 | 15.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
858 | 15.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
859 | 15.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
860 | 15.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
861 | 16 | SPARES | |||
862 | 17 | 5A | |||
863 | 17.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
864 | 17.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
865 | 17.03 | Calibration of O/L Relay | 1 | Nos | |
866 | 17.04 | Repair of Coils | 1 | Nos | |
867 | 17.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
868 | 17.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
869 | 17.07 | Replacement of Push Button switches | 1 | Nos | |
870 | 17.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
871 | 17.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
872 | 17.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
873 | 17.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
874 | 17.12 | Repair of Control Transformers | 1 | Nos | |
875 | 17.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
876 | 17.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
877 | 17.15 | Replacement of Control Fuses | 1 | Nos | |
878 | 17.16 | Replacement of time delay relay | 1 | Nos | |
879 | 17.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
880 | 17.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
881 | 17.19 | Replacement of Rotary Switches | 1 | Nos | |
882 | 17.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
883 | 17.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
884 | 17.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
885 | 17.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
886 | 17.24 | Replacement of Lock Pins | 1 | Nos | |
887 | 17.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
888 | 17.26 | Replacement of Ebonite Board | 1 | Nos | |
889 | 17.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
890 | 17.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
891 | 17.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
892 | 17.3 | Replacement of Change Over Handle | 1 | Nos | |
893 | 17.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
894 | 17.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
895 | 17.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
896 | 17.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
897 | 17.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
898 | 17.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
899 | 17.37 | Repair of Amp/Volt Meter | 1 | Nos | |
900 | 17.38 | Painting | 1 | Nos | |
901 | 17.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
902 | 17.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
903 | 17.41 | Repair of Electronic Protection Unit | 1 | Nos | |
904 | 17.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
905 | 17.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
906 | 17.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
907 | 17.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
908 | 17.46 | Replacement of MCCB | 1 | Nos | |
909 | 17.47 | Replacement of Power Diode | 1 | Nos | |
910 | 17.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
911 | 17.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
912 | 17.5 | Replacement of Overload Relay | 1 | Nos | |
913 | 17.51 | Replacement of Coils | 1 | Nos | |
914 | 17.52 | Replacement of Voltage Relays | 1 | Nos | |
915 | 17.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
916 | 17.54 | Renewal of 3 Core Cable | 1 | Nos | |
917 | 17.55 | Replacement of Control Transformers | 1 | Nos | |
918 | 17.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
919 | 17.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
920 | 17.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
921 | 17.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
922 | 17.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
923 | 17.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
924 | 17.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
925 | 17.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
926 | 17.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
927 | 17.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
928 | 18 | 5.1-10A | |||
929 | 18.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
930 | 18.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
931 | 18.03 | Calibration of O/L Relay | 1 | Nos | |
932 | 18.04 | Repair of Coils | 1 | Nos | |
933 | 18.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
934 | 18.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
935 | 18.07 | Replacement of Push Button switches | 1 | Nos | |
936 | 18.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 7 | Nos | |
937 | 18.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
938 | 18.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
939 | 18.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
940 | 18.12 | Repair of Control Transformers | 1 | Nos | |
941 | 18.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
942 | 18.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
943 | 18.15 | Replacement of Control Fuses | 13 | Nos | |
944 | 18.16 | Replacement of time delay relay | 1 | Nos | |
945 | 18.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
946 | 18.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
947 | 18.19 | Replacement of Rotary Switches | 1 | Nos | |
948 | 18.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
949 | 18.21 | Replacement of Bakelite Moulding Rate/MM | 10 | Nos | |
950 | 18.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
951 | 18.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
952 | 18.24 | Replacement of Lock Pins | 1 | Nos | |
953 | 18.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
954 | 18.26 | Replacement of Ebonite Board | 1 | Nos | |
955 | 18.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
956 | 18.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
957 | 18.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
958 | 18.3 | Replacement of Change Over Handle | 1 | Nos | |
959 | 18.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
960 | 18.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
961 | 18.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
962 | 18.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
963 | 18.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
964 | 18.36 | Replacement of NO/NC Auxiliary Contacts | 2 | Nos | |
965 | 18.37 | Repair of Amp/Volt Meter | 1 | Nos | |
966 | 18.38 | Painting | 1 | Nos | |
967 | 18.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
968 | 18.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
969 | 18.41 | Repair of Electronic Protection Unit | 2 | Nos | |
970 | 18.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
971 | 18.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
972 | 18.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
973 | 18.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
974 | 18.46 | Replacement of MCCB | 1 | Nos | |
975 | 18.47 | Replacement of Power Diode | 1 | Nos | |
976 | 18.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
977 | 18.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
978 | 18.5 | Replacement of Overload Relay | 6 | Nos | |
979 | 18.51 | Replacement of Coils | 1 | Nos | |
980 | 18.52 | Replacement of Voltage Relays | 1 | Nos | |
981 | 18.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
982 | 18.54 | Renewal of 3 Core Cable | 1 | Nos | |
983 | 18.55 | Replacement of Control Transformers | 1 | Nos | |
984 | 18.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
985 | 18.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
986 | 18.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
987 | 18.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
988 | 18.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
989 | 18.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
990 | 18.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
991 | 18.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
992 | 18.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
993 | 18.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
994 | 19 | 10.1-15A | |||
995 | 19.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 58 | Nos | |
996 | 19.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
997 | 19.03 | Calibration of O/L Relay | 1 | Nos | |
998 | 19.04 | Repair of Coils | 1 | Nos | |
999 | 19.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 7 | Nos | |
1000 | 19.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 47 | Nos | |
1001 | 19.07 | Replacement of Push Button switches | 1 | Nos | |
1002 | 19.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 38 | Nos | |
1003 | 19.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 5 | Nos | |
1004 | 19.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1005 | 19.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1006 | 19.12 | Repair of Control Transformers | 2 | Nos | |
1007 | 19.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
1008 | 19.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1009 | 19.15 | Replacement of Control Fuses | 99 | Nos | |
1010 | 19.16 | Replacement of time delay relay | 6 | Nos | |
1011 | 19.17 | Replacement of Indication Lamps and Holders | 6 | Nos | |
1012 | 19.18 | Replacement of ON/OFF Push Units | 2 | Nos | |
1013 | 19.19 | Replacement of Rotary Switches | 1 | Nos | |
1014 | 19.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1015 | 19.21 | Replacement of Bakelite Moulding Rate/MM | 7 | Nos | |
1016 | 19.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
1017 | 19.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1018 | 19.24 | Replacement of Lock Pins | 1 | Nos | |
1019 | 19.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1020 | 19.26 | Replacement of Ebonite Board | 1 | Nos | |
1021 | 19.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1022 | 19.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1023 | 19.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
1024 | 19.3 | Replacement of Change Over Handle | 1 | Nos | |
1025 | 19.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
1026 | 19.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1027 | 19.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1028 | 19.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1029 | 19.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1030 | 19.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
1031 | 19.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1032 | 19.38 | Painting | 1 | Nos | |
1033 | 19.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1034 | 19.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1035 | 19.41 | Repair of Electronic Protection Unit | 5 | Nos | |
1036 | 19.42 | Replacement of Electronic Protection Unit | 26 | Nos | |
1037 | 19.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1038 | 19.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1039 | 19.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1040 | 19.46 | Replacement of MCCB | 1 | Nos | |
1041 | 19.47 | Replacement of Power Diode | 1 | Nos | |
1042 | 19.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1043 | 19.49 | Replacement of Socket (Brass & Ebonite) | 2 | Nos | |
1044 | 19.5 | Replacement of Overload Relay | 53 | Nos | |
1045 | 19.51 | Replacement of Coils | 3 | Nos | |
1046 | 19.52 | Replacement of Voltage Relays | 2 | Nos | |
1047 | 19.53 | Replacement of ON/OFF Stage Over Switch | 21 | Nos | |
1048 | 19.54 | Renewal of 3 Core Cable | 1 | Nos | |
1049 | 19.55 | Replacement of Control Transformers | 1 | Nos | |
1050 | 19.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1051 | 19.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1052 | 19.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1053 | 19.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1054 | 19.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1055 | 19.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1056 | 19.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1057 | 19.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1058 | 19.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
1059 | 19.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1060 | 20 | 15.1-20A | |||
1061 | 20.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 14 | Nos | |
1062 | 20.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1063 | 20.03 | Calibration of O/L Relay | 1 | Nos | |
1064 | 20.04 | Repair of Coils | 1 | Nos | |
1065 | 20.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
1066 | 20.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 11 | Nos | |
1067 | 20.07 | Replacement of Push Button switches | 1 | Nos | |
1068 | 20.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 3 | Nos | |
1069 | 20.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1070 | 20.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1071 | 20.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1072 | 20.12 | Repair of Control Transformers | 1 | Nos | |
1073 | 20.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 2 | Nos | |
1074 | 20.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1075 | 20.15 | Replacement of Control Fuses | 25 | Nos | |
1076 | 20.16 | Replacement of time delay relay | 4 | Nos | |
1077 | 20.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1078 | 20.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1079 | 20.19 | Replacement of Rotary Switches | 1 | Nos | |
1080 | 20.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1081 | 20.21 | Replacement of Bakelite Moulding Rate/MM | 8 | Nos | |
1082 | 20.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
1083 | 20.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1084 | 20.24 | Replacement of Lock Pins | 1 | Nos | |
1085 | 20.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1086 | 20.26 | Replacement of Ebonite Board | 1 | Nos | |
1087 | 20.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1088 | 20.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1089 | 20.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
1090 | 20.3 | Replacement of Change Over Handle | 1 | Nos | |
1091 | 20.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1092 | 20.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1093 | 20.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1094 | 20.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1095 | 20.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1096 | 20.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
1097 | 20.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1098 | 20.38 | Painting | 2 | Nos | |
1099 | 20.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1100 | 20.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1101 | 20.41 | Repair of Electronic Protection Unit | 2 | Nos | |
1102 | 20.42 | Replacement of Electronic Protection Unit | 5 | Nos | |
1103 | 20.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1104 | 20.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1105 | 20.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1106 | 20.46 | Replacement of MCCB | 1 | Nos | |
1107 | 20.47 | Replacement of Power Diode | 1 | Nos | |
1108 | 20.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1109 | 20.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1110 | 20.5 | Replacement of Overload Relay | 12 | Nos | |
1111 | 20.51 | Replacement of Coils | 1 | Nos | |
1112 | 20.52 | Replacement of Voltage Relays | 1 | Nos | |
1113 | 20.53 | Replacement of ON/OFF Stage Over Switch | 8 | Nos | |
1114 | 20.54 | Renewal of 3 Core Cable | 1 | Nos | |
1115 | 20.55 | Replacement of Control Transformers | 1 | Nos | |
1116 | 20.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1117 | 20.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1118 | 20.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1119 | 20.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1120 | 20.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1121 | 20.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1122 | 20.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1123 | 20.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1124 | 20.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
1125 | 20.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1126 | 21 | 20.1-30A | |||
1127 | 21.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 2 | Nos | |
1128 | 21.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1129 | 21.03 | Calibration of O/L Relay | 1 | Nos | |
1130 | 21.04 | Repair of Coils | 1 | Nos | |
1131 | 21.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
1132 | 21.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
1133 | 21.07 | Replacement of Push Button switches | 1 | Nos | |
1134 | 21.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 5 | Nos | |
1135 | 21.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1136 | 21.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1137 | 21.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1138 | 21.12 | Repair of Control Transformers | 1 | Nos | |
1139 | 21.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1140 | 21.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1141 | 21.15 | Replacement of Control Fuses | 2 | Nos | |
1142 | 21.16 | Replacement of time delay relay | 1 | Nos | |
1143 | 21.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1144 | 21.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1145 | 21.19 | Replacement of Rotary Switches | 1 | Nos | |
1146 | 21.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1147 | 21.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
1148 | 21.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 2 | Nos | |
1149 | 21.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1150 | 21.24 | Replacement of Lock Pins | 1 | Nos | |
1151 | 21.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1152 | 21.26 | Replacement of Ebonite Board | 1 | Nos | |
1153 | 21.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1154 | 21.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1155 | 21.29 | Replacement of Wire Wound Resistors | 2 | Nos | |
1156 | 21.3 | Replacement of Change Over Handle | 1 | Nos | |
1157 | 21.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1158 | 21.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1159 | 21.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1160 | 21.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1161 | 21.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1162 | 21.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
1163 | 21.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1164 | 21.38 | Painting | 1 | Nos | |
1165 | 21.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1166 | 21.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1167 | 21.41 | Repair of Electronic Protection Unit | 1 | Nos | |
1168 | 21.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
1169 | 21.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1170 | 21.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1171 | 21.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1172 | 21.46 | Replacement of MCCB | 1 | Nos | |
1173 | 21.47 | Replacement of Power Diode | 1 | Nos | |
1174 | 21.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1175 | 21.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1176 | 21.5 | Replacement of Overload Relay | 2 | Nos | |
1177 | 21.51 | Replacement of Coils | 1 | Nos | |
1178 | 21.52 | Replacement of Voltage Relays | 1 | Nos | |
1179 | 21.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
1180 | 21.54 | Renewal of 3 Core Cable | 1 | Nos | |
1181 | 21.55 | Replacement of Control Transformers | 1 | Nos | |
1182 | 21.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1183 | 21.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1184 | 21.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1185 | 21.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1186 | 21.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1187 | 21.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1188 | 21.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1189 | 21.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1190 | 21.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
1191 | 21.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1192 | 22 | 30.1-50A | |||
1193 | 22.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 8 | Nos | |
1194 | 22.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1195 | 22.03 | Calibration of O/L Relay | 1 | Nos | |
1196 | 22.04 | Repair of Coils | 1 | Nos | |
1197 | 22.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 3 | Nos | |
1198 | 22.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
1199 | 22.07 | Replacement of Push Button switches | 1 | Nos | |
1200 | 22.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 15 | Nos | |
1201 | 22.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1202 | 22.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1203 | 22.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1204 | 22.12 | Repair of Control Transformers | 1 | Nos | |
1205 | 22.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1206 | 22.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1207 | 22.15 | Replacement of Control Fuses | 14 | Nos | |
1208 | 22.16 | Replacement of time delay relay | 3 | Nos | |
1209 | 22.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1210 | 22.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1211 | 22.19 | Replacement of Rotary Switches | 1 | Nos | |
1212 | 22.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1213 | 22.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
1214 | 22.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 24 | Nos | |
1215 | 22.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1216 | 22.24 | Replacement of Lock Pins | 1 | Nos | |
1217 | 22.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1218 | 22.26 | Replacement of Ebonite Board | 1 | Nos | |
1219 | 22.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1220 | 22.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1221 | 22.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
1222 | 22.3 | Replacement of Change Over Handle | 1 | Nos | |
1223 | 22.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1224 | 22.32 | Repair of 3 Ph 4 Way Rotary Switch | 4 | Nos | |
1225 | 22.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1226 | 22.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1227 | 22.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1228 | 22.36 | Replacement of NO/NC Auxiliary Contacts | 7 | Nos | |
1229 | 22.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1230 | 22.38 | Painting | 1 | Nos | |
1231 | 22.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1232 | 22.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1233 | 22.41 | Repair of Electronic Protection Unit | 2 | Nos | |
1234 | 22.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
1235 | 22.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1236 | 22.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1237 | 22.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1238 | 22.46 | Replacement of MCCB | 1 | Nos | |
1239 | 22.47 | Replacement of Power Diode | 20 | Nos | |
1240 | 22.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1241 | 22.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1242 | 22.5 | Replacement of Overload Relay | 2 | Nos | |
1243 | 22.51 | Replacement of Coils | 3 | Nos | |
1244 | 22.52 | Replacement of Voltage Relays | 6 | Nos | |
1245 | 22.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
1246 | 22.54 | Renewal of 3 Core Cable | 1 | Nos | |
1247 | 22.55 | Replacement of Control Transformers | 1 | Nos | |
1248 | 22.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1249 | 22.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1250 | 22.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1251 | 22.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1252 | 22.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1253 | 22.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1254 | 22.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1255 | 22.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1256 | 22.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 6 | Nos | |
1257 | 22.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
1258 | 23 | 50.1-75A | |||
1259 | 23.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 7 | Nos | |
1260 | 23.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1261 | 23.03 | Calibration of O/L Relay | 1 | Nos | |
1262 | 23.04 | Repair of Coils | 1 | Nos | |
1263 | 23.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
1264 | 23.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 4 | Nos | |
1265 | 23.07 | Replacement of Push Button switches | 1 | Nos | |
1266 | 23.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 40 | Nos | |
1267 | 23.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1268 | 23.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1269 | 23.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1270 | 23.12 | Repair of Control Transformers | 1 | Nos | |
1271 | 23.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1272 | 23.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1273 | 23.15 | Replacement of Control Fuses | 20 | Nos | |
1274 | 23.16 | Replacement of time delay relay | 1 | Nos | |
1275 | 23.17 | Replacement of Indication Lamps and Holders | 3 | Nos | |
1276 | 23.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1277 | 23.19 | Replacement of Rotary Switches | 1 | Nos | |
1278 | 23.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1279 | 23.21 | Replacement of Bakelite Moulding Rate/MM | 9 | Nos | |
1280 | 23.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 18 | Nos | |
1281 | 23.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1282 | 23.24 | Replacement of Lock Pins | 1 | Nos | |
1283 | 23.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1284 | 23.26 | Replacement of Ebonite Board | 1 | Nos | |
1285 | 23.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1286 | 23.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1287 | 23.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
1288 | 23.3 | Replacement of Change Over Handle | 1 | Nos | |
1289 | 23.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
1290 | 23.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1291 | 23.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1292 | 23.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1293 | 23.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1294 | 23.36 | Replacement of NO/NC Auxiliary Contacts | 13 | Nos | |
1295 | 23.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1296 | 23.38 | Painting | 1 | Nos | |
1297 | 23.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1298 | 23.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1299 | 23.41 | Repair of Electronic Protection Unit | 3 | Nos | |
1300 | 23.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
1301 | 23.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1302 | 23.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1303 | 23.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1304 | 23.46 | Replacement of MCCB | 1 | Nos | |
1305 | 23.47 | Replacement of Power Diode | 5 | Nos | |
1306 | 23.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1307 | 23.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1308 | 23.5 | Replacement of Overload Relay | 1 | Nos | |
1309 | 23.51 | Replacement of Coils | 1 | Nos | |
1310 | 23.52 | Replacement of Voltage Relays | 3 | Nos | |
1311 | 23.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
1312 | 23.54 | Renewal of 3 Core Cable | 1 | Nos | |
1313 | 23.55 | Replacement of Control Transformers | 1 | Nos | |
1314 | 23.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1315 | 23.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1316 | 23.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1317 | 23.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1318 | 23.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1319 | 23.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1320 | 23.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1321 | 23.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1322 | 23.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
1323 | 23.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1324 | 24 | 75.1-100A | |||
1325 | 24.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 9 | Nos | |
1326 | 24.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1327 | 24.03 | Calibration of O/L Relay | 1 | Nos | |
1328 | 24.04 | Repair of Coils | 1 | Nos | |
1329 | 24.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 4 | Nos | |
1330 | 24.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
1331 | 24.07 | Replacement of Push Button switches | 1 | Nos | |
1332 | 24.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 25 | Nos | |
1333 | 24.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1334 | 24.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1335 | 24.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1336 | 24.12 | Repair of Control Transformers | 1 | Nos | |
1337 | 24.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1338 | 24.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1339 | 24.15 | Replacement of Control Fuses | 17 | Nos | |
1340 | 24.16 | Replacement of time delay relay | 4 | Nos | |
1341 | 24.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1342 | 24.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1343 | 24.19 | Replacement of Rotary Switches | 1 | Nos | |
1344 | 24.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1345 | 24.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
1346 | 24.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 27 | Nos | |
1347 | 24.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1348 | 24.24 | Replacement of Lock Pins | 1 | Nos | |
1349 | 24.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1350 | 24.26 | Replacement of Ebonite Board | 1 | Nos | |
1351 | 24.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 9 | Nos | |
1352 | 24.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1353 | 24.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
1354 | 24.3 | Replacement of Change Over Handle | 1 | Nos | |
1355 | 24.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1356 | 24.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1357 | 24.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1358 | 24.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1359 | 24.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1360 | 24.36 | Replacement of NO/NC Auxiliary Contacts | 10 | Nos | |
1361 | 24.37 | Repair of Amp/Volt Meter | 2 | Nos | |
1362 | 24.38 | Painting | 1 | Nos | |
1363 | 24.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1364 | 24.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1365 | 24.41 | Repair of Electronic Protection Unit | 1 | Nos | |
1366 | 24.42 | Replacement of Electronic Protection Unit | 2 | Nos | |
1367 | 24.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1368 | 24.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1369 | 24.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1370 | 24.46 | Replacement of MCCB | 1 | Nos | |
1371 | 24.47 | Replacement of Power Diode | 18 | Nos | |
1372 | 24.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1373 | 24.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1374 | 24.5 | Replacement of Overload Relay | 3 | Nos | |
1375 | 24.51 | Replacement of Coils | 3 | Nos | |
1376 | 24.52 | Replacement of Voltage Relays | 6 | Nos | |
1377 | 24.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
1378 | 24.54 | Renewal of 3 Core Cable | 1 | Nos | |
1379 | 24.55 | Replacement of Control Transformers | 1 | Nos | |
1380 | 24.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1381 | 24.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1382 | 24.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1383 | 24.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1384 | 24.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1385 | 24.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1386 | 24.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1387 | 24.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1388 | 24.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
1389 | 24.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 3 | Nos | |
1390 | 25 | 100.1-150A | |||
1391 | 25.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 21 | Nos | |
1392 | 25.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1393 | 25.03 | Calibration of O/L Relay | 1 | Nos | |
1394 | 25.04 | Repair of Coils | 1 | Nos | |
1395 | 25.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 5 | Nos | |
1396 | 25.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
1397 | 25.07 | Replacement of Push Button switches | 1 | Nos | |
1398 | 25.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 79 | Nos | |
1399 | 25.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1400 | 25.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 2 | Nos | |
1401 | 25.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1402 | 25.12 | Repair of Control Transformers | 1 | Nos | |
1403 | 25.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1404 | 25.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
1405 | 25.15 | Replacement of Control Fuses | 43 | Nos | |
1406 | 25.16 | Replacement of time delay relay | 16 | Nos | |
1407 | 25.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1408 | 25.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1409 | 25.19 | Replacement of Rotary Switches | 1 | Nos | |
1410 | 25.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1411 | 25.21 | Replacement of Bakelite Moulding Rate/MM | 15 | Nos | |
1412 | 25.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 61 | Nos | |
1413 | 25.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 4 | Nos | |
1414 | 25.24 | Replacement of Lock Pins | 1 | Nos | |
1415 | 25.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1416 | 25.26 | Replacement of Ebonite Board | 1 | Nos | |
1417 | 25.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 10 | Nos | |
1418 | 25.28 | Replacement of Bakelite Switches and Knobs | 2 | Nos | |
1419 | 25.29 | Replacement of Wire Wound Resistors | 67 | Nos | |
1420 | 25.3 | Replacement of Change Over Handle | 1 | Nos | |
1421 | 25.31 | Repair of Single Phase Protection Unit | 3 | Nos | |
1422 | 25.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1423 | 25.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1424 | 25.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1425 | 25.35 | Replacement of Rubber Beading of Starter (Gasket) | 2 | Nos | |
1426 | 25.36 | Replacement of NO/NC Auxiliary Contacts | 51 | Nos | |
1427 | 25.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1428 | 25.38 | Painting | 1 | Nos | |
1429 | 25.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1430 | 25.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1431 | 25.41 | Repair of Electronic Protection Unit | 1 | Nos | |
1432 | 25.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
1433 | 25.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1434 | 25.44 | Replacement of TPU (Thermal Power Unit) | 4 | Nos | |
1435 | 25.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 12 | Nos | |
1436 | 25.46 | Replacement of MCCB | 1 | Nos | |
1437 | 25.47 | Replacement of Power Diode | 94 | Nos | |
1438 | 25.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 3 | Nos | |
1439 | 25.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1440 | 25.5 | Replacement of Overload Relay | 4 | Nos | |
1441 | 25.51 | Replacement of Coils | 9 | Nos | |
1442 | 25.52 | Replacement of Voltage Relays | 9 | Nos | |
1443 | 25.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
1444 | 25.54 | Renewal of 3 Core Cable | 1 | Nos | |
1445 | 25.55 | Replacement of Control Transformers | 1 | Nos | |
1446 | 25.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1447 | 25.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1448 | 25.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1449 | 25.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1450 | 25.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1451 | 25.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1452 | 25.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1453 | 25.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1454 | 25.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 9 | Nos | |
1455 | 25.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 4 | Nos | |
1456 | 26 | 150.1-200A | |||
1457 | 26.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
1458 | 26.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1459 | 26.03 | Calibration of O/L Relay | 1 | Nos | |
1460 | 26.04 | Repair of Coils | 1 | Nos | |
1461 | 26.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
1462 | 26.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
1463 | 26.07 | Replacement of Push Button switches | 1 | Nos | |
1464 | 26.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 10 | Nos | |
1465 | 26.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1466 | 26.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1467 | 26.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1468 | 26.12 | Repair of Control Transformers | 1 | Nos | |
1469 | 26.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1470 | 26.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1471 | 26.15 | Replacement of Control Fuses | 6 | Nos | |
1472 | 26.16 | Replacement of time delay relay | 3 | Nos | |
1473 | 26.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1474 | 26.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1475 | 26.19 | Replacement of Rotary Switches | 1 | Nos | |
1476 | 26.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1477 | 26.21 | Replacement of Bakelite Moulding Rate/MM | 2 | Nos | |
1478 | 26.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 21 | Nos | |
1479 | 26.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1480 | 26.24 | Replacement of Lock Pins | 1 | Nos | |
1481 | 26.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1482 | 26.26 | Replacement of Ebonite Board | 1 | Nos | |
1483 | 26.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1484 | 26.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1485 | 26.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
1486 | 26.3 | Replacement of Change Over Handle | 1 | Nos | |
1487 | 26.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1488 | 26.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1489 | 26.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1490 | 26.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1491 | 26.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1492 | 26.36 | Replacement of NO/NC Auxiliary Contacts | 6 | Nos | |
1493 | 26.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1494 | 26.38 | Painting | 1 | Nos | |
1495 | 26.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1496 | 26.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1497 | 26.41 | Repair of Electronic Protection Unit | 1 | Nos | |
1498 | 26.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
1499 | 26.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1500 | 26.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1501 | 26.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 2 | Nos | |
1502 | 26.46 | Replacement of MCCB | 1 | Nos | |
1503 | 26.47 | Replacement of Power Diode | 4 | Nos | |
1504 | 26.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1505 | 26.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1506 | 26.5 | Replacement of Overload Relay | 1 | Nos | |
1507 | 26.51 | Replacement of Coils | 1 | Nos | |
1508 | 26.52 | Replacement of Voltage Relays | 3 | Nos | |
1509 | 26.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
1510 | 26.54 | Renewal of 3 Core Cable | 1 | Nos | |
1511 | 26.55 | Replacement of Control Transformers | 1 | Nos | |
1512 | 26.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1513 | 26.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1514 | 26.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1515 | 26.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1516 | 26.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1517 | 26.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1518 | 26.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1519 | 26.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1520 | 26.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 2 | Nos | |
1521 | 26.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
1522 | 27 | 200.1-300A | |||
1523 | 27.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
1524 | 27.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1525 | 27.03 | Calibration of O/L Relay | 1 | Nos | |
1526 | 27.04 | Repair of Coils | 1 | Nos | |
1527 | 27.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
1528 | 27.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
1529 | 27.07 | Replacement of Push Button switches | 1 | Nos | |
1530 | 27.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 17 | Nos | |
1531 | 27.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1532 | 27.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1533 | 27.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1534 | 27.12 | Repair of Control Transformers | 1 | Nos | |
1535 | 27.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1536 | 27.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1537 | 27.15 | Replacement of Control Fuses | 7 | Nos | |
1538 | 27.16 | Replacement of time delay relay | 3 | Nos | |
1539 | 27.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1540 | 27.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1541 | 27.19 | Replacement of Rotary Switches | 1 | Nos | |
1542 | 27.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1543 | 27.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
1544 | 27.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 17 | Nos | |
1545 | 27.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1546 | 27.24 | Replacement of Lock Pins | 1 | Nos | |
1547 | 27.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1548 | 27.26 | Replacement of Ebonite Board | 1 | Nos | |
1549 | 27.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1550 | 27.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1551 | 27.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
1552 | 27.3 | Replacement of Change Over Handle | 1 | Nos | |
1553 | 27.31 | Repair of Single Phase Protection Unit | 2 | Nos | |
1554 | 27.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1555 | 27.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1556 | 27.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1557 | 27.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1558 | 27.36 | Replacement of NO/NC Auxiliary Contacts | 11 | Nos | |
1559 | 27.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1560 | 27.38 | Painting | 1 | Nos | |
1561 | 27.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1562 | 27.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1563 | 27.41 | Repair of Electronic Protection Unit | 1 | Nos | |
1564 | 27.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
1565 | 27.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1566 | 27.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1567 | 27.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1568 | 27.46 | Replacement of MCCB | 1 | Nos | |
1569 | 27.47 | Replacement of Power Diode | 4 | Nos | |
1570 | 27.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1571 | 27.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1572 | 27.5 | Replacement of Overload Relay | 1 | Nos | |
1573 | 27.51 | Replacement of Coils | 1 | Nos | |
1574 | 27.52 | Replacement of Voltage Relays | 5 | Nos | |
1575 | 27.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
1576 | 27.54 | Renewal of 3 Core Cable | 1 | Nos | |
1577 | 27.55 | Replacement of Control Transformers | 1 | Nos | |
1578 | 27.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1579 | 27.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1580 | 27.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1581 | 27.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1582 | 27.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1583 | 27.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1584 | 27.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1585 | 27.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1586 | 27.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
1587 | 27.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1588 | 28 | 300.1-500A | |||
1589 | 28.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
1590 | 28.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1591 | 28.03 | Calibration of O/L Relay | 1 | Nos | |
1592 | 28.04 | Repair of Coils | 1 | Nos | |
1593 | 28.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
1594 | 28.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
1595 | 28.07 | Replacement of Push Button switches | 1 | Nos | |
1596 | 28.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
1597 | 28.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1598 | 28.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1599 | 28.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1600 | 28.12 | Repair of Control Transformers | 1 | Nos | |
1601 | 28.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1602 | 28.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1603 | 28.15 | Replacement of Control Fuses | 1 | Nos | |
1604 | 28.16 | Replacement of time delay relay | 1 | Nos | |
1605 | 28.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1606 | 28.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1607 | 28.19 | Replacement of Rotary Switches | 1 | Nos | |
1608 | 28.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1609 | 28.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
1610 | 28.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 40 | Nos | |
1611 | 28.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1612 | 28.24 | Replacement of Lock Pins | 1 | Nos | |
1613 | 28.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1614 | 28.26 | Replacement of Ebonite Board | 1 | Nos | |
1615 | 28.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1616 | 28.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1617 | 28.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
1618 | 28.3 | Replacement of Change Over Handle | 1 | Nos | |
1619 | 28.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1620 | 28.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1621 | 28.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1622 | 28.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1623 | 28.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1624 | 28.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
1625 | 28.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1626 | 28.38 | Painting | 1 | Nos | |
1627 | 28.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1628 | 28.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1629 | 28.41 | Repair of Electronic Protection Unit | 1 | Nos | |
1630 | 28.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
1631 | 28.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1632 | 28.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1633 | 28.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1634 | 28.46 | Replacement of MCCB | 1 | Nos | |
1635 | 28.47 | Replacement of Power Diode | 1 | Nos | |
1636 | 28.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1637 | 28.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1638 | 28.5 | Replacement of Overload Relay | 1 | Nos | |
1639 | 28.51 | Replacement of Coils | 1 | Nos | |
1640 | 28.52 | Replacement of Voltage Relays | 1 | Nos | |
1641 | 28.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
1642 | 28.54 | Renewal of 3 Core Cable | 1 | Nos | |
1643 | 28.55 | Replacement of Control Transformers | 1 | Nos | |
1644 | 28.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1645 | 28.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1646 | 28.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1647 | 28.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1648 | 28.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1649 | 28.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1650 | 28.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1651 | 28.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1652 | 28.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
1653 | 28.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1654 | 29 | 500.1-600A | |||
1655 | 29.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
1656 | 29.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1657 | 29.03 | Calibration of O/L Relay | 1 | Nos | |
1658 | 29.04 | Repair of Coils | 1 | Nos | |
1659 | 29.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
1660 | 29.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
1661 | 29.07 | Replacement of Push Button switches | 1 | Nos | |
1662 | 29.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
1663 | 29.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1664 | 29.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1665 | 29.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1666 | 29.12 | Repair of Control Transformers | 1 | Nos | |
1667 | 29.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1668 | 29.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1669 | 29.15 | Replacement of Control Fuses | 1 | Nos | |
1670 | 29.16 | Replacement of time delay relay | 1 | Nos | |
1671 | 29.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1672 | 29.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1673 | 29.19 | Replacement of Rotary Switches | 1 | Nos | |
1674 | 29.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1675 | 29.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
1676 | 29.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 3 | Nos | |
1677 | 29.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1678 | 29.24 | Replacement of Lock Pins | 1 | Nos | |
1679 | 29.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1680 | 29.26 | Replacement of Ebonite Board | 1 | Nos | |
1681 | 29.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1682 | 29.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1683 | 29.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
1684 | 29.3 | Replacement of Change Over Handle | 1 | Nos | |
1685 | 29.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1686 | 29.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1687 | 29.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1688 | 29.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1689 | 29.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1690 | 29.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
1691 | 29.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1692 | 29.38 | Painting | 1 | Nos | |
1693 | 29.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1694 | 29.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1695 | 29.41 | Repair of Electronic Protection Unit | 1 | Nos | |
1696 | 29.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
1697 | 29.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1698 | 29.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1699 | 29.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1700 | 29.46 | Replacement of MCCB | 1 | Nos | |
1701 | 29.47 | Replacement of Power Diode | 1 | Nos | |
1702 | 29.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1703 | 29.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1704 | 29.5 | Replacement of Overload Relay | 1 | Nos | |
1705 | 29.51 | Replacement of Coils | 1 | Nos | |
1706 | 29.52 | Replacement of Voltage Relays | 1 | Nos | |
1707 | 29.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
1708 | 29.54 | Renewal of 3 Core Cable | 1 | Nos | |
1709 | 29.55 | Replacement of Control Transformers | 1 | Nos | |
1710 | 29.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1711 | 29.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1712 | 29.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1713 | 29.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1714 | 29.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1715 | 29.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1716 | 29.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1717 | 29.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1718 | 29.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
1719 | 29.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1720 | 30 | SECOND YEAR | |||
1721 | 31 | SERVICES | |||
1722 | 32 | 5A | |||
1723 | 32.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
1724 | 32.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1725 | 32.03 | Calibration of O/L Relay | 1 | Nos | |
1726 | 32.04 | Repair of Coils | 1 | Nos | |
1727 | 32.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
1728 | 32.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
1729 | 32.07 | Replacement of Push Button switches | 1 | Nos | |
1730 | 32.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
1731 | 32.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1732 | 32.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1733 | 32.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1734 | 32.12 | Repair of Control Transformers | 1 | Nos | |
1735 | 32.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1736 | 32.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1737 | 32.15 | Replacement of Control Fuses | 1 | Nos | |
1738 | 32.16 | Replacement of time delay relay | 1 | Nos | |
1739 | 32.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1740 | 32.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1741 | 32.19 | Replacement of Rotary Switches | 1 | Nos | |
1742 | 32.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1743 | 32.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
1744 | 32.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
1745 | 32.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1746 | 32.24 | Replacement of Lock Pins | 1 | Nos | |
1747 | 32.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1748 | 32.26 | Replacement of Ebonite Board | 1 | Nos | |
1749 | 32.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1750 | 32.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1751 | 32.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
1752 | 32.3 | Replacement of Change Over Handle | 1 | Nos | |
1753 | 32.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1754 | 32.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1755 | 32.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1756 | 32.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1757 | 32.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1758 | 32.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
1759 | 32.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1760 | 32.38 | Painting | 1 | Nos | |
1761 | 32.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1762 | 32.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1763 | 32.41 | Repair of Electronic Protection Unit | 1 | Nos | |
1764 | 32.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
1765 | 32.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1766 | 32.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1767 | 32.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1768 | 32.46 | Replacement of MCCB | 1 | Nos | |
1769 | 32.47 | Replacement of Power Diode | 1 | Nos | |
1770 | 32.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1771 | 32.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1772 | 32.5 | Replacement of Overload Relay | 1 | Nos | |
1773 | 32.51 | Replacement of Coils | 1 | Nos | |
1774 | 32.52 | Replacement of Voltage Relays | 1 | Nos | |
1775 | 32.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
1776 | 32.54 | Renewal of 3 Core Cable | 1 | Nos | |
1777 | 32.55 | Replacement of Control Transformers | 1 | Nos | |
1778 | 32.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1779 | 32.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1780 | 32.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1781 | 32.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1782 | 32.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1783 | 32.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1784 | 32.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1785 | 32.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1786 | 32.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
1787 | 32.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1788 | 33 | 5.1-10A | |||
1789 | 33.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
1790 | 33.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1791 | 33.03 | Calibration of O/L Relay | 1 | Nos | |
1792 | 33.04 | Repair of Coils | 1 | Nos | |
1793 | 33.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
1794 | 33.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
1795 | 33.07 | Replacement of Push Button switches | 1 | Nos | |
1796 | 33.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 7 | Nos | |
1797 | 33.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1798 | 33.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1799 | 33.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1800 | 33.12 | Repair of Control Transformers | 1 | Nos | |
1801 | 33.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1802 | 33.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1803 | 33.15 | Replacement of Control Fuses | 13 | Nos | |
1804 | 33.16 | Replacement of time delay relay | 1 | Nos | |
1805 | 33.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1806 | 33.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1807 | 33.19 | Replacement of Rotary Switches | 1 | Nos | |
1808 | 33.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1809 | 33.21 | Replacement of Bakelite Moulding Rate/MM | 10 | Nos | |
1810 | 33.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
1811 | 33.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1812 | 33.24 | Replacement of Lock Pins | 1 | Nos | |
1813 | 33.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1814 | 33.26 | Replacement of Ebonite Board | 1 | Nos | |
1815 | 33.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1816 | 33.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1817 | 33.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
1818 | 33.3 | Replacement of Change Over Handle | 1 | Nos | |
1819 | 33.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1820 | 33.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1821 | 33.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1822 | 33.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1823 | 33.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1824 | 33.36 | Replacement of NO/NC Auxiliary Contacts | 2 | Nos | |
1825 | 33.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1826 | 33.38 | Painting | 1 | Nos | |
1827 | 33.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1828 | 33.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1829 | 33.41 | Repair of Electronic Protection Unit | 2 | Nos | |
1830 | 33.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
1831 | 33.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1832 | 33.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1833 | 33.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1834 | 33.46 | Replacement of MCCB | 1 | Nos | |
1835 | 33.47 | Replacement of Power Diode | 1 | Nos | |
1836 | 33.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1837 | 33.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1838 | 33.5 | Replacement of Overload Relay | 6 | Nos | |
1839 | 33.51 | Replacement of Coils | 1 | Nos | |
1840 | 33.52 | Replacement of Voltage Relays | 1 | Nos | |
1841 | 33.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
1842 | 33.54 | Renewal of 3 Core Cable | 1 | Nos | |
1843 | 33.55 | Replacement of Control Transformers | 1 | Nos | |
1844 | 33.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1845 | 33.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1846 | 33.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1847 | 33.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1848 | 33.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1849 | 33.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1850 | 33.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1851 | 33.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1852 | 33.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
1853 | 33.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1854 | 34 | 10.1-15A | |||
1855 | 34.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 58 | Nos | |
1856 | 34.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1857 | 34.03 | Calibration of O/L Relay | 1 | Nos | |
1858 | 34.04 | Repair of Coils | 1 | Nos | |
1859 | 34.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 7 | Nos | |
1860 | 34.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 47 | Nos | |
1861 | 34.07 | Replacement of Push Button switches | 1 | Nos | |
1862 | 34.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 38 | Nos | |
1863 | 34.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 5 | Nos | |
1864 | 34.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1865 | 34.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1866 | 34.12 | Repair of Control Transformers | 2 | Nos | |
1867 | 34.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
1868 | 34.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1869 | 34.15 | Replacement of Control Fuses | 99 | Nos | |
1870 | 34.16 | Replacement of time delay relay | 6 | Nos | |
1871 | 34.17 | Replacement of Indication Lamps and Holders | 6 | Nos | |
1872 | 34.18 | Replacement of ON/OFF Push Units | 2 | Nos | |
1873 | 34.19 | Replacement of Rotary Switches | 1 | Nos | |
1874 | 34.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1875 | 34.21 | Replacement of Bakelite Moulding Rate/MM | 7 | Nos | |
1876 | 34.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
1877 | 34.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1878 | 34.24 | Replacement of Lock Pins | 1 | Nos | |
1879 | 34.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1880 | 34.26 | Replacement of Ebonite Board | 1 | Nos | |
1881 | 34.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1882 | 34.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1883 | 34.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
1884 | 34.3 | Replacement of Change Over Handle | 1 | Nos | |
1885 | 34.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
1886 | 34.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1887 | 34.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1888 | 34.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1889 | 34.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1890 | 34.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
1891 | 34.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1892 | 34.38 | Painting | 1 | Nos | |
1893 | 34.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1894 | 34.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1895 | 34.41 | Repair of Electronic Protection Unit | 5 | Nos | |
1896 | 34.42 | Replacement of Electronic Protection Unit | 26 | Nos | |
1897 | 34.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1898 | 34.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1899 | 34.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1900 | 34.46 | Replacement of MCCB | 1 | Nos | |
1901 | 34.47 | Replacement of Power Diode | 1 | Nos | |
1902 | 34.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1903 | 34.49 | Replacement of Socket (Brass & Ebonite) | 2 | Nos | |
1904 | 34.5 | Replacement of Overload Relay | 53 | Nos | |
1905 | 34.51 | Replacement of Coils | 3 | Nos | |
1906 | 34.52 | Replacement of Voltage Relays | 2 | Nos | |
1907 | 34.53 | Replacement of ON/OFF Stage Over Switch | 21 | Nos | |
1908 | 34.54 | Renewal of 3 Core Cable | 1 | Nos | |
1909 | 34.55 | Replacement of Control Transformers | 1 | Nos | |
1910 | 34.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1911 | 34.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1912 | 34.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1913 | 34.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1914 | 34.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1915 | 34.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1916 | 34.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1917 | 34.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1918 | 34.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
1919 | 34.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1920 | 35 | 15.1-20A | |||
1921 | 35.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 14 | Nos | |
1922 | 35.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1923 | 35.03 | Calibration of O/L Relay | 1 | Nos | |
1924 | 35.04 | Repair of Coils | 1 | Nos | |
1925 | 35.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
1926 | 35.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 11 | Nos | |
1927 | 35.07 | Replacement of Push Button switches | 1 | Nos | |
1928 | 35.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 3 | Nos | |
1929 | 35.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1930 | 35.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1931 | 35.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1932 | 35.12 | Repair of Control Transformers | 1 | Nos | |
1933 | 35.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 2 | Nos | |
1934 | 35.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
1935 | 35.15 | Replacement of Control Fuses | 25 | Nos | |
1936 | 35.16 | Replacement of time delay relay | 4 | Nos | |
1937 | 35.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
1938 | 35.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
1939 | 35.19 | Replacement of Rotary Switches | 1 | Nos | |
1940 | 35.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
1941 | 35.21 | Replacement of Bakelite Moulding Rate/MM | 8 | Nos | |
1942 | 35.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
1943 | 35.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
1944 | 35.24 | Replacement of Lock Pins | 1 | Nos | |
1945 | 35.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
1946 | 35.26 | Replacement of Ebonite Board | 1 | Nos | |
1947 | 35.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
1948 | 35.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
1949 | 35.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
1950 | 35.3 | Replacement of Change Over Handle | 1 | Nos | |
1951 | 35.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
1952 | 35.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1953 | 35.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
1954 | 35.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
1955 | 35.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
1956 | 35.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
1957 | 35.37 | Repair of Amp/Volt Meter | 1 | Nos | |
1958 | 35.38 | Painting | 2 | Nos | |
1959 | 35.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1960 | 35.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
1961 | 35.41 | Repair of Electronic Protection Unit | 2 | Nos | |
1962 | 35.42 | Replacement of Electronic Protection Unit | 5 | Nos | |
1963 | 35.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
1964 | 35.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
1965 | 35.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
1966 | 35.46 | Replacement of MCCB | 1 | Nos | |
1967 | 35.47 | Replacement of Power Diode | 1 | Nos | |
1968 | 35.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
1969 | 35.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
1970 | 35.5 | Replacement of Overload Relay | 12 | Nos | |
1971 | 35.51 | Replacement of Coils | 1 | Nos | |
1972 | 35.52 | Replacement of Voltage Relays | 1 | Nos | |
1973 | 35.53 | Replacement of ON/OFF Stage Over Switch | 8 | Nos | |
1974 | 35.54 | Renewal of 3 Core Cable | 1 | Nos | |
1975 | 35.55 | Replacement of Control Transformers | 1 | Nos | |
1976 | 35.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
1977 | 35.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
1978 | 35.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
1979 | 35.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
1980 | 35.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1981 | 35.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1982 | 35.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1983 | 35.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
1984 | 35.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
1985 | 35.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
1986 | 36 | 20.1-30A | |||
1987 | 36.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 2 | Nos | |
1988 | 36.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
1989 | 36.03 | Calibration of O/L Relay | 1 | Nos | |
1990 | 36.04 | Repair of Coils | 1 | Nos | |
1991 | 36.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
1992 | 36.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
1993 | 36.07 | Replacement of Push Button switches | 1 | Nos | |
1994 | 36.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 5 | Nos | |
1995 | 36.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
1996 | 36.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
1997 | 36.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
1998 | 36.12 | Repair of Control Transformers | 1 | Nos | |
1999 | 36.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2000 | 36.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2001 | 36.15 | Replacement of Control Fuses | 2 | Nos | |
2002 | 36.16 | Replacement of time delay relay | 1 | Nos | |
2003 | 36.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2004 | 36.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2005 | 36.19 | Replacement of Rotary Switches | 1 | Nos | |
2006 | 36.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2007 | 36.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
2008 | 36.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 2 | Nos | |
2009 | 36.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2010 | 36.24 | Replacement of Lock Pins | 1 | Nos | |
2011 | 36.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2012 | 36.26 | Replacement of Ebonite Board | 1 | Nos | |
2013 | 36.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2014 | 36.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2015 | 36.29 | Replacement of Wire Wound Resistors | 2 | Nos | |
2016 | 36.3 | Replacement of Change Over Handle | 1 | Nos | |
2017 | 36.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2018 | 36.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2019 | 36.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2020 | 36.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2021 | 36.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2022 | 36.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
2023 | 36.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2024 | 36.38 | Painting | 1 | Nos | |
2025 | 36.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2026 | 36.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2027 | 36.41 | Repair of Electronic Protection Unit | 1 | Nos | |
2028 | 36.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2029 | 36.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2030 | 36.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2031 | 36.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2032 | 36.46 | Replacement of MCCB | 1 | Nos | |
2033 | 36.47 | Replacement of Power Diode | 1 | Nos | |
2034 | 36.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2035 | 36.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2036 | 36.5 | Replacement of Overload Relay | 2 | Nos | |
2037 | 36.51 | Replacement of Coils | 1 | Nos | |
2038 | 36.52 | Replacement of Voltage Relays | 1 | Nos | |
2039 | 36.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
2040 | 36.54 | Renewal of 3 Core Cable | 1 | Nos | |
2041 | 36.55 | Replacement of Control Transformers | 1 | Nos | |
2042 | 36.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2043 | 36.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2044 | 36.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2045 | 36.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2046 | 36.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2047 | 36.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2048 | 36.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2049 | 36.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2050 | 36.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
2051 | 36.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2052 | 37 | 30.1-50A | |||
2053 | 37.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 8 | Nos | |
2054 | 37.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2055 | 37.03 | Calibration of O/L Relay | 1 | Nos | |
2056 | 37.04 | Repair of Coils | 1 | Nos | |
2057 | 37.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 3 | Nos | |
2058 | 37.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
2059 | 37.07 | Replacement of Push Button switches | 1 | Nos | |
2060 | 37.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 15 | Nos | |
2061 | 37.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2062 | 37.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2063 | 37.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2064 | 37.12 | Repair of Control Transformers | 1 | Nos | |
2065 | 37.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2066 | 37.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2067 | 37.15 | Replacement of Control Fuses | 14 | Nos | |
2068 | 37.16 | Replacement of time delay relay | 3 | Nos | |
2069 | 37.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2070 | 37.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2071 | 37.19 | Replacement of Rotary Switches | 1 | Nos | |
2072 | 37.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2073 | 37.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
2074 | 37.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 24 | Nos | |
2075 | 37.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2076 | 37.24 | Replacement of Lock Pins | 1 | Nos | |
2077 | 37.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2078 | 37.26 | Replacement of Ebonite Board | 1 | Nos | |
2079 | 37.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2080 | 37.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2081 | 37.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
2082 | 37.3 | Replacement of Change Over Handle | 1 | Nos | |
2083 | 37.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2084 | 37.32 | Repair of 3 Ph 4 Way Rotary Switch | 4 | Nos | |
2085 | 37.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2086 | 37.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2087 | 37.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2088 | 37.36 | Replacement of NO/NC Auxiliary Contacts | 7 | Nos | |
2089 | 37.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2090 | 37.38 | Painting | 1 | Nos | |
2091 | 37.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2092 | 37.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2093 | 37.41 | Repair of Electronic Protection Unit | 2 | Nos | |
2094 | 37.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2095 | 37.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2096 | 37.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2097 | 37.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2098 | 37.46 | Replacement of MCCB | 1 | Nos | |
2099 | 37.47 | Replacement of Power Diode | 20 | Nos | |
2100 | 37.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2101 | 37.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2102 | 37.5 | Replacement of Overload Relay | 2 | Nos | |
2103 | 37.51 | Replacement of Coils | 3 | Nos | |
2104 | 37.52 | Replacement of Voltage Relays | 6 | Nos | |
2105 | 37.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
2106 | 37.54 | Renewal of 3 Core Cable | 1 | Nos | |
2107 | 37.55 | Replacement of Control Transformers | 1 | Nos | |
2108 | 37.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2109 | 37.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2110 | 37.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2111 | 37.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2112 | 37.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2113 | 37.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2114 | 37.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2115 | 37.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2116 | 37.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 6 | Nos | |
2117 | 37.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
2118 | 38 | 50.1-75A | |||
2119 | 38.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 7 | Nos | |
2120 | 38.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2121 | 38.03 | Calibration of O/L Relay | 1 | Nos | |
2122 | 38.04 | Repair of Coils | 1 | Nos | |
2123 | 38.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
2124 | 38.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 4 | Nos | |
2125 | 38.07 | Replacement of Push Button switches | 1 | Nos | |
2126 | 38.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 40 | Nos | |
2127 | 38.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2128 | 38.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2129 | 38.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2130 | 38.12 | Repair of Control Transformers | 1 | Nos | |
2131 | 38.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2132 | 38.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2133 | 38.15 | Replacement of Control Fuses | 20 | Nos | |
2134 | 38.16 | Replacement of time delay relay | 1 | Nos | |
2135 | 38.17 | Replacement of Indication Lamps and Holders | 3 | Nos | |
2136 | 38.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2137 | 38.19 | Replacement of Rotary Switches | 1 | Nos | |
2138 | 38.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2139 | 38.21 | Replacement of Bakelite Moulding Rate/MM | 9 | Nos | |
2140 | 38.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 18 | Nos | |
2141 | 38.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2142 | 38.24 | Replacement of Lock Pins | 1 | Nos | |
2143 | 38.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2144 | 38.26 | Replacement of Ebonite Board | 1 | Nos | |
2145 | 38.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2146 | 38.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2147 | 38.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
2148 | 38.3 | Replacement of Change Over Handle | 1 | Nos | |
2149 | 38.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
2150 | 38.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2151 | 38.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2152 | 38.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2153 | 38.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2154 | 38.36 | Replacement of NO/NC Auxiliary Contacts | 13 | Nos | |
2155 | 38.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2156 | 38.38 | Painting | 1 | Nos | |
2157 | 38.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2158 | 38.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2159 | 38.41 | Repair of Electronic Protection Unit | 3 | Nos | |
2160 | 38.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
2161 | 38.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2162 | 38.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2163 | 38.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2164 | 38.46 | Replacement of MCCB | 1 | Nos | |
2165 | 38.47 | Replacement of Power Diode | 5 | Nos | |
2166 | 38.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2167 | 38.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2168 | 38.5 | Replacement of Overload Relay | 1 | Nos | |
2169 | 38.51 | Replacement of Coils | 1 | Nos | |
2170 | 38.52 | Replacement of Voltage Relays | 3 | Nos | |
2171 | 38.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
2172 | 38.54 | Renewal of 3 Core Cable | 1 | Nos | |
2173 | 38.55 | Replacement of Control Transformers | 1 | Nos | |
2174 | 38.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2175 | 38.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2176 | 38.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2177 | 38.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2178 | 38.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2179 | 38.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2180 | 38.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2181 | 38.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2182 | 38.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
2183 | 38.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2184 | 39 | 75.1-100A | |||
2185 | 39.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 9 | Nos | |
2186 | 39.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2187 | 39.03 | Calibration of O/L Relay | 1 | Nos | |
2188 | 39.04 | Repair of Coils | 1 | Nos | |
2189 | 39.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 4 | Nos | |
2190 | 39.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
2191 | 39.07 | Replacement of Push Button switches | 1 | Nos | |
2192 | 39.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 25 | Nos | |
2193 | 39.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2194 | 39.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2195 | 39.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2196 | 39.12 | Repair of Control Transformers | 1 | Nos | |
2197 | 39.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2198 | 39.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2199 | 39.15 | Replacement of Control Fuses | 17 | Nos | |
2200 | 39.16 | Replacement of time delay relay | 4 | Nos | |
2201 | 39.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2202 | 39.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2203 | 39.19 | Replacement of Rotary Switches | 1 | Nos | |
2204 | 39.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2205 | 39.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
2206 | 39.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 27 | Nos | |
2207 | 39.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2208 | 39.24 | Replacement of Lock Pins | 1 | Nos | |
2209 | 39.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2210 | 39.26 | Replacement of Ebonite Board | 1 | Nos | |
2211 | 39.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 9 | Nos | |
2212 | 39.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2213 | 39.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
2214 | 39.3 | Replacement of Change Over Handle | 1 | Nos | |
2215 | 39.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2216 | 39.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2217 | 39.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2218 | 39.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2219 | 39.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2220 | 39.36 | Replacement of NO/NC Auxiliary Contacts | 10 | Nos | |
2221 | 39.37 | Repair of Amp/Volt Meter | 2 | Nos | |
2222 | 39.38 | Painting | 1 | Nos | |
2223 | 39.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2224 | 39.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2225 | 39.41 | Repair of Electronic Protection Unit | 1 | Nos | |
2226 | 39.42 | Replacement of Electronic Protection Unit | 2 | Nos | |
2227 | 39.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2228 | 39.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2229 | 39.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2230 | 39.46 | Replacement of MCCB | 1 | Nos | |
2231 | 39.47 | Replacement of Power Diode | 18 | Nos | |
2232 | 39.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2233 | 39.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2234 | 39.5 | Replacement of Overload Relay | 3 | Nos | |
2235 | 39.51 | Replacement of Coils | 3 | Nos | |
2236 | 39.52 | Replacement of Voltage Relays | 6 | Nos | |
2237 | 39.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
2238 | 39.54 | Renewal of 3 Core Cable | 1 | Nos | |
2239 | 39.55 | Replacement of Control Transformers | 1 | Nos | |
2240 | 39.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2241 | 39.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2242 | 39.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2243 | 39.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2244 | 39.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2245 | 39.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2246 | 39.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2247 | 39.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2248 | 39.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
2249 | 39.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 3 | Nos | |
2250 | 40 | 100.1-150A | |||
2251 | 40.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 21 | Nos | |
2252 | 40.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2253 | 40.03 | Calibration of O/L Relay | 1 | Nos | |
2254 | 40.04 | Repair of Coils | 1 | Nos | |
2255 | 40.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 5 | Nos | |
2256 | 40.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
2257 | 40.07 | Replacement of Push Button switches | 1 | Nos | |
2258 | 40.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 79 | Nos | |
2259 | 40.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2260 | 40.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 2 | Nos | |
2261 | 40.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2262 | 40.12 | Repair of Control Transformers | 1 | Nos | |
2263 | 40.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2264 | 40.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
2265 | 40.15 | Replacement of Control Fuses | 43 | Nos | |
2266 | 40.16 | Replacement of time delay relay | 16 | Nos | |
2267 | 40.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2268 | 40.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2269 | 40.19 | Replacement of Rotary Switches | 1 | Nos | |
2270 | 40.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2271 | 40.21 | Replacement of Bakelite Moulding Rate/MM | 15 | Nos | |
2272 | 40.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 61 | Nos | |
2273 | 40.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 4 | Nos | |
2274 | 40.24 | Replacement of Lock Pins | 1 | Nos | |
2275 | 40.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2276 | 40.26 | Replacement of Ebonite Board | 1 | Nos | |
2277 | 40.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 10 | Nos | |
2278 | 40.28 | Replacement of Bakelite Switches and Knobs | 2 | Nos | |
2279 | 40.29 | Replacement of Wire Wound Resistors | 67 | Nos | |
2280 | 40.3 | Replacement of Change Over Handle | 1 | Nos | |
2281 | 40.31 | Repair of Single Phase Protection Unit | 3 | Nos | |
2282 | 40.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2283 | 40.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2284 | 40.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2285 | 40.35 | Replacement of Rubber Beading of Starter (Gasket) | 2 | Nos | |
2286 | 40.36 | Replacement of NO/NC Auxiliary Contacts | 51 | Nos | |
2287 | 40.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2288 | 40.38 | Painting | 1 | Nos | |
2289 | 40.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2290 | 40.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2291 | 40.41 | Repair of Electronic Protection Unit | 1 | Nos | |
2292 | 40.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2293 | 40.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2294 | 40.44 | Replacement of TPU (Thermal Power Unit) | 4 | Nos | |
2295 | 40.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 12 | Nos | |
2296 | 40.46 | Replacement of MCCB | 1 | Nos | |
2297 | 40.47 | Replacement of Power Diode | 94 | Nos | |
2298 | 40.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 3 | Nos | |
2299 | 40.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2300 | 40.5 | Replacement of Overload Relay | 4 | Nos | |
2301 | 40.51 | Replacement of Coils | 9 | Nos | |
2302 | 40.52 | Replacement of Voltage Relays | 9 | Nos | |
2303 | 40.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
2304 | 40.54 | Renewal of 3 Core Cable | 1 | Nos | |
2305 | 40.55 | Replacement of Control Transformers | 1 | Nos | |
2306 | 40.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2307 | 40.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2308 | 40.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2309 | 40.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2310 | 40.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2311 | 40.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2312 | 40.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2313 | 40.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2314 | 40.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 9 | Nos | |
2315 | 40.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 4 | Nos | |
2316 | 41 | 150.1-200A | |||
2317 | 41.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
2318 | 41.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2319 | 41.03 | Calibration of O/L Relay | 1 | Nos | |
2320 | 41.04 | Repair of Coils | 1 | Nos | |
2321 | 41.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
2322 | 41.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
2323 | 41.07 | Replacement of Push Button switches | 1 | Nos | |
2324 | 41.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 10 | Nos | |
2325 | 41.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2326 | 41.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2327 | 41.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2328 | 41.12 | Repair of Control Transformers | 1 | Nos | |
2329 | 41.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2330 | 41.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2331 | 41.15 | Replacement of Control Fuses | 6 | Nos | |
2332 | 41.16 | Replacement of time delay relay | 3 | Nos | |
2333 | 41.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2334 | 41.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2335 | 41.19 | Replacement of Rotary Switches | 1 | Nos | |
2336 | 41.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2337 | 41.21 | Replacement of Bakelite Moulding Rate/MM | 2 | Nos | |
2338 | 41.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 21 | Nos | |
2339 | 41.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2340 | 41.24 | Replacement of Lock Pins | 1 | Nos | |
2341 | 41.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2342 | 41.26 | Replacement of Ebonite Board | 1 | Nos | |
2343 | 41.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2344 | 41.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2345 | 41.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
2346 | 41.3 | Replacement of Change Over Handle | 1 | Nos | |
2347 | 41.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2348 | 41.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2349 | 41.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2350 | 41.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2351 | 41.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2352 | 41.36 | Replacement of NO/NC Auxiliary Contacts | 6 | Nos | |
2353 | 41.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2354 | 41.38 | Painting | 1 | Nos | |
2355 | 41.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2356 | 41.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2357 | 41.41 | Repair of Electronic Protection Unit | 1 | Nos | |
2358 | 41.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2359 | 41.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2360 | 41.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2361 | 41.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 2 | Nos | |
2362 | 41.46 | Replacement of MCCB | 1 | Nos | |
2363 | 41.47 | Replacement of Power Diode | 4 | Nos | |
2364 | 41.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2365 | 41.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2366 | 41.5 | Replacement of Overload Relay | 1 | Nos | |
2367 | 41.51 | Replacement of Coils | 1 | Nos | |
2368 | 41.52 | Replacement of Voltage Relays | 3 | Nos | |
2369 | 41.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
2370 | 41.54 | Renewal of 3 Core Cable | 1 | Nos | |
2371 | 41.55 | Replacement of Control Transformers | 1 | Nos | |
2372 | 41.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2373 | 41.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2374 | 41.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2375 | 41.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2376 | 41.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2377 | 41.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2378 | 41.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2379 | 41.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2380 | 41.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 2 | Nos | |
2381 | 41.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
2382 | 42 | 200.1-300A | |||
2383 | 42.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
2384 | 42.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2385 | 42.03 | Calibration of O/L Relay | 1 | Nos | |
2386 | 42.04 | Repair of Coils | 1 | Nos | |
2387 | 42.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
2388 | 42.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
2389 | 42.07 | Replacement of Push Button switches | 1 | Nos | |
2390 | 42.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 17 | Nos | |
2391 | 42.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2392 | 42.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2393 | 42.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2394 | 42.12 | Repair of Control Transformers | 1 | Nos | |
2395 | 42.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2396 | 42.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2397 | 42.15 | Replacement of Control Fuses | 7 | Nos | |
2398 | 42.16 | Replacement of time delay relay | 3 | Nos | |
2399 | 42.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2400 | 42.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2401 | 42.19 | Replacement of Rotary Switches | 1 | Nos | |
2402 | 42.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2403 | 42.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
2404 | 42.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 17 | Nos | |
2405 | 42.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2406 | 42.24 | Replacement of Lock Pins | 1 | Nos | |
2407 | 42.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2408 | 42.26 | Replacement of Ebonite Board | 1 | Nos | |
2409 | 42.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2410 | 42.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2411 | 42.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
2412 | 42.3 | Replacement of Change Over Handle | 1 | Nos | |
2413 | 42.31 | Repair of Single Phase Protection Unit | 2 | Nos | |
2414 | 42.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2415 | 42.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2416 | 42.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2417 | 42.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2418 | 42.36 | Replacement of NO/NC Auxiliary Contacts | 11 | Nos | |
2419 | 42.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2420 | 42.38 | Painting | 1 | Nos | |
2421 | 42.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2422 | 42.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2423 | 42.41 | Repair of Electronic Protection Unit | 1 | Nos | |
2424 | 42.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2425 | 42.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2426 | 42.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2427 | 42.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2428 | 42.46 | Replacement of MCCB | 1 | Nos | |
2429 | 42.47 | Replacement of Power Diode | 4 | Nos | |
2430 | 42.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2431 | 42.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2432 | 42.5 | Replacement of Overload Relay | 1 | Nos | |
2433 | 42.51 | Replacement of Coils | 1 | Nos | |
2434 | 42.52 | Replacement of Voltage Relays | 5 | Nos | |
2435 | 42.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
2436 | 42.54 | Renewal of 3 Core Cable | 1 | Nos | |
2437 | 42.55 | Replacement of Control Transformers | 1 | Nos | |
2438 | 42.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2439 | 42.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2440 | 42.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2441 | 42.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2442 | 42.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2443 | 42.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2444 | 42.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2445 | 42.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2446 | 42.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
2447 | 42.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2448 | 43 | 300.1-500A | |||
2449 | 43.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
2450 | 43.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2451 | 43.03 | Calibration of O/L Relay | 1 | Nos | |
2452 | 43.04 | Repair of Coils | 1 | Nos | |
2453 | 43.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
2454 | 43.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
2455 | 43.07 | Replacement of Push Button switches | 1 | Nos | |
2456 | 43.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
2457 | 43.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2458 | 43.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2459 | 43.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2460 | 43.12 | Repair of Control Transformers | 1 | Nos | |
2461 | 43.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2462 | 43.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2463 | 43.15 | Replacement of Control Fuses | 1 | Nos | |
2464 | 43.16 | Replacement of time delay relay | 1 | Nos | |
2465 | 43.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2466 | 43.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2467 | 43.19 | Replacement of Rotary Switches | 1 | Nos | |
2468 | 43.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2469 | 43.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
2470 | 43.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 40 | Nos | |
2471 | 43.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2472 | 43.24 | Replacement of Lock Pins | 1 | Nos | |
2473 | 43.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2474 | 43.26 | Replacement of Ebonite Board | 1 | Nos | |
2475 | 43.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2476 | 43.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2477 | 43.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
2478 | 43.3 | Replacement of Change Over Handle | 1 | Nos | |
2479 | 43.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2480 | 43.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2481 | 43.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2482 | 43.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2483 | 43.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2484 | 43.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
2485 | 43.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2486 | 43.38 | Painting | 1 | Nos | |
2487 | 43.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2488 | 43.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2489 | 43.41 | Repair of Electronic Protection Unit | 1 | Nos | |
2490 | 43.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2491 | 43.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2492 | 43.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2493 | 43.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2494 | 43.46 | Replacement of MCCB | 1 | Nos | |
2495 | 43.47 | Replacement of Power Diode | 1 | Nos | |
2496 | 43.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2497 | 43.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2498 | 43.5 | Replacement of Overload Relay | 1 | Nos | |
2499 | 43.51 | Replacement of Coils | 1 | Nos | |
2500 | 43.52 | Replacement of Voltage Relays | 1 | Nos | |
2501 | 43.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
2502 | 43.54 | Renewal of 3 Core Cable | 1 | Nos | |
2503 | 43.55 | Replacement of Control Transformers | 1 | Nos | |
2504 | 43.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2505 | 43.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2506 | 43.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2507 | 43.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2508 | 43.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2509 | 43.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2510 | 43.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2511 | 43.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2512 | 43.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
2513 | 43.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2514 | 44 | 500.1-600A | |||
2515 | 44.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
2516 | 44.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2517 | 44.03 | Calibration of O/L Relay | 1 | Nos | |
2518 | 44.04 | Repair of Coils | 1 | Nos | |
2519 | 44.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
2520 | 44.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
2521 | 44.07 | Replacement of Push Button switches | 1 | Nos | |
2522 | 44.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
2523 | 44.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2524 | 44.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2525 | 44.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2526 | 44.12 | Repair of Control Transformers | 1 | Nos | |
2527 | 44.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2528 | 44.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2529 | 44.15 | Replacement of Control Fuses | 1 | Nos | |
2530 | 44.16 | Replacement of time delay relay | 1 | Nos | |
2531 | 44.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2532 | 44.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2533 | 44.19 | Replacement of Rotary Switches | 1 | Nos | |
2534 | 44.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2535 | 44.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
2536 | 44.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 3 | Nos | |
2537 | 44.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2538 | 44.24 | Replacement of Lock Pins | 1 | Nos | |
2539 | 44.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2540 | 44.26 | Replacement of Ebonite Board | 1 | Nos | |
2541 | 44.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2542 | 44.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2543 | 44.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
2544 | 44.3 | Replacement of Change Over Handle | 1 | Nos | |
2545 | 44.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2546 | 44.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2547 | 44.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2548 | 44.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2549 | 44.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2550 | 44.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
2551 | 44.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2552 | 44.38 | Painting | 1 | Nos | |
2553 | 44.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2554 | 44.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2555 | 44.41 | Repair of Electronic Protection Unit | 1 | Nos | |
2556 | 44.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2557 | 44.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2558 | 44.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2559 | 44.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2560 | 44.46 | Replacement of MCCB | 1 | Nos | |
2561 | 44.47 | Replacement of Power Diode | 1 | Nos | |
2562 | 44.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2563 | 44.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2564 | 44.5 | Replacement of Overload Relay | 1 | Nos | |
2565 | 44.51 | Replacement of Coils | 1 | Nos | |
2566 | 44.52 | Replacement of Voltage Relays | 1 | Nos | |
2567 | 44.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
2568 | 44.54 | Renewal of 3 Core Cable | 1 | Nos | |
2569 | 44.55 | Replacement of Control Transformers | 1 | Nos | |
2570 | 44.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2571 | 44.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2572 | 44.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2573 | 44.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2574 | 44.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2575 | 44.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2576 | 44.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2577 | 44.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2578 | 44.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
2579 | 44.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2580 | 45 | SPARES | |||
2581 | 46 | 5A | |||
2582 | 46.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
2583 | 46.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2584 | 46.03 | Calibration of O/L Relay | 1 | Nos | |
2585 | 46.04 | Repair of Coils | 1 | Nos | |
2586 | 46.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
2587 | 46.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
2588 | 46.07 | Replacement of Push Button switches | 1 | Nos | |
2589 | 46.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
2590 | 46.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2591 | 46.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2592 | 46.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2593 | 46.12 | Repair of Control Transformers | 1 | Nos | |
2594 | 46.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2595 | 46.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2596 | 46.15 | Replacement of Control Fuses | 1 | Nos | |
2597 | 46.16 | Replacement of time delay relay | 1 | Nos | |
2598 | 46.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2599 | 46.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2600 | 46.19 | Replacement of Rotary Switches | 1 | Nos | |
2601 | 46.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2602 | 46.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
2603 | 46.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
2604 | 46.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2605 | 46.24 | Replacement of Lock Pins | 1 | Nos | |
2606 | 46.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2607 | 46.26 | Replacement of Ebonite Board | 1 | Nos | |
2608 | 46.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2609 | 46.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2610 | 46.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
2611 | 46.3 | Replacement of Change Over Handle | 1 | Nos | |
2612 | 46.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2613 | 46.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2614 | 46.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2615 | 46.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2616 | 46.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2617 | 46.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
2618 | 46.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2619 | 46.38 | Painting | 1 | Nos | |
2620 | 46.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2621 | 46.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2622 | 46.41 | Repair of Electronic Protection Unit | 1 | Nos | |
2623 | 46.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2624 | 46.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2625 | 46.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2626 | 46.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2627 | 46.46 | Replacement of MCCB | 1 | Nos | |
2628 | 46.47 | Replacement of Power Diode | 1 | Nos | |
2629 | 46.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2630 | 46.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2631 | 46.5 | Replacement of Overload Relay | 1 | Nos | |
2632 | 46.51 | Replacement of Coils | 1 | Nos | |
2633 | 46.52 | Replacement of Voltage Relays | 1 | Nos | |
2634 | 46.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
2635 | 46.54 | Renewal of 3 Core Cable | 1 | Nos | |
2636 | 46.55 | Replacement of Control Transformers | 1 | Nos | |
2637 | 46.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2638 | 46.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2639 | 46.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2640 | 46.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2641 | 46.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2642 | 46.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2643 | 46.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2644 | 46.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2645 | 46.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
2646 | 46.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2647 | 47 | 5.1-10A | |||
2648 | 47.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
2649 | 47.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2650 | 47.03 | Calibration of O/L Relay | 1 | Nos | |
2651 | 47.04 | Repair of Coils | 1 | Nos | |
2652 | 47.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
2653 | 47.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
2654 | 47.07 | Replacement of Push Button switches | 1 | Nos | |
2655 | 47.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 7 | Nos | |
2656 | 47.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2657 | 47.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2658 | 47.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2659 | 47.12 | Repair of Control Transformers | 1 | Nos | |
2660 | 47.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2661 | 47.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2662 | 47.15 | Replacement of Control Fuses | 13 | Nos | |
2663 | 47.16 | Replacement of time delay relay | 1 | Nos | |
2664 | 47.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2665 | 47.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2666 | 47.19 | Replacement of Rotary Switches | 1 | Nos | |
2667 | 47.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2668 | 47.21 | Replacement of Bakelite Moulding Rate/MM | 10 | Nos | |
2669 | 47.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
2670 | 47.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2671 | 47.24 | Replacement of Lock Pins | 1 | Nos | |
2672 | 47.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2673 | 47.26 | Replacement of Ebonite Board | 1 | Nos | |
2674 | 47.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2675 | 47.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2676 | 47.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
2677 | 47.3 | Replacement of Change Over Handle | 1 | Nos | |
2678 | 47.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2679 | 47.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2680 | 47.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2681 | 47.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2682 | 47.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2683 | 47.36 | Replacement of NO/NC Auxiliary Contacts | 2 | Nos | |
2684 | 47.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2685 | 47.38 | Painting | 1 | Nos | |
2686 | 47.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2687 | 47.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2688 | 47.41 | Repair of Electronic Protection Unit | 2 | Nos | |
2689 | 47.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
2690 | 47.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2691 | 47.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2692 | 47.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2693 | 47.46 | Replacement of MCCB | 1 | Nos | |
2694 | 47.47 | Replacement of Power Diode | 1 | Nos | |
2695 | 47.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2696 | 47.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2697 | 47.5 | Replacement of Overload Relay | 6 | Nos | |
2698 | 47.51 | Replacement of Coils | 1 | Nos | |
2699 | 47.52 | Replacement of Voltage Relays | 1 | Nos | |
2700 | 47.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
2701 | 47.54 | Renewal of 3 Core Cable | 1 | Nos | |
2702 | 47.55 | Replacement of Control Transformers | 1 | Nos | |
2703 | 47.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2704 | 47.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2705 | 47.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2706 | 47.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2707 | 47.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2708 | 47.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2709 | 47.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2710 | 47.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2711 | 47.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
2712 | 47.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2713 | 48 | 10.1-15A | |||
2714 | 48.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 58 | Nos | |
2715 | 48.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2716 | 48.03 | Calibration of O/L Relay | 1 | Nos | |
2717 | 48.04 | Repair of Coils | 1 | Nos | |
2718 | 48.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 7 | Nos | |
2719 | 48.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 47 | Nos | |
2720 | 48.07 | Replacement of Push Button switches | 1 | Nos | |
2721 | 48.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 38 | Nos | |
2722 | 48.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 5 | Nos | |
2723 | 48.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2724 | 48.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2725 | 48.12 | Repair of Control Transformers | 2 | Nos | |
2726 | 48.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
2727 | 48.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2728 | 48.15 | Replacement of Control Fuses | 99 | Nos | |
2729 | 48.16 | Replacement of time delay relay | 6 | Nos | |
2730 | 48.17 | Replacement of Indication Lamps and Holders | 6 | Nos | |
2731 | 48.18 | Replacement of ON/OFF Push Units | 2 | Nos | |
2732 | 48.19 | Replacement of Rotary Switches | 1 | Nos | |
2733 | 48.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2734 | 48.21 | Replacement of Bakelite Moulding Rate/MM | 7 | Nos | |
2735 | 48.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
2736 | 48.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2737 | 48.24 | Replacement of Lock Pins | 1 | Nos | |
2738 | 48.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2739 | 48.26 | Replacement of Ebonite Board | 1 | Nos | |
2740 | 48.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2741 | 48.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2742 | 48.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
2743 | 48.3 | Replacement of Change Over Handle | 1 | Nos | |
2744 | 48.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
2745 | 48.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2746 | 48.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2747 | 48.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2748 | 48.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2749 | 48.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
2750 | 48.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2751 | 48.38 | Painting | 1 | Nos | |
2752 | 48.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2753 | 48.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2754 | 48.41 | Repair of Electronic Protection Unit | 5 | Nos | |
2755 | 48.42 | Replacement of Electronic Protection Unit | 26 | Nos | |
2756 | 48.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2757 | 48.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2758 | 48.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2759 | 48.46 | Replacement of MCCB | 1 | Nos | |
2760 | 48.47 | Replacement of Power Diode | 1 | Nos | |
2761 | 48.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2762 | 48.49 | Replacement of Socket (Brass & Ebonite) | 2 | Nos | |
2763 | 48.5 | Replacement of Overload Relay | 53 | Nos | |
2764 | 48.51 | Replacement of Coils | 3 | Nos | |
2765 | 48.52 | Replacement of Voltage Relays | 2 | Nos | |
2766 | 48.53 | Replacement of ON/OFF Stage Over Switch | 21 | Nos | |
2767 | 48.54 | Renewal of 3 Core Cable | 1 | Nos | |
2768 | 48.55 | Replacement of Control Transformers | 1 | Nos | |
2769 | 48.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2770 | 48.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2771 | 48.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2772 | 48.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2773 | 48.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2774 | 48.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2775 | 48.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2776 | 48.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2777 | 48.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
2778 | 48.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2779 | 49 | 15.1-20A | |||
2780 | 49.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 14 | Nos | |
2781 | 49.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2782 | 49.03 | Calibration of O/L Relay | 1 | Nos | |
2783 | 49.04 | Repair of Coils | 1 | Nos | |
2784 | 49.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
2785 | 49.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 11 | Nos | |
2786 | 49.07 | Replacement of Push Button switches | 1 | Nos | |
2787 | 49.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 3 | Nos | |
2788 | 49.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2789 | 49.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2790 | 49.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2791 | 49.12 | Repair of Control Transformers | 1 | Nos | |
2792 | 49.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 2 | Nos | |
2793 | 49.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2794 | 49.15 | Replacement of Control Fuses | 25 | Nos | |
2795 | 49.16 | Replacement of time delay relay | 4 | Nos | |
2796 | 49.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2797 | 49.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2798 | 49.19 | Replacement of Rotary Switches | 1 | Nos | |
2799 | 49.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2800 | 49.21 | Replacement of Bakelite Moulding Rate/MM | 8 | Nos | |
2801 | 49.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
2802 | 49.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2803 | 49.24 | Replacement of Lock Pins | 1 | Nos | |
2804 | 49.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2805 | 49.26 | Replacement of Ebonite Board | 1 | Nos | |
2806 | 49.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2807 | 49.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2808 | 49.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
2809 | 49.3 | Replacement of Change Over Handle | 1 | Nos | |
2810 | 49.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2811 | 49.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2812 | 49.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2813 | 49.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2814 | 49.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2815 | 49.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
2816 | 49.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2817 | 49.38 | Painting | 2 | Nos | |
2818 | 49.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2819 | 49.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2820 | 49.41 | Repair of Electronic Protection Unit | 2 | Nos | |
2821 | 49.42 | Replacement of Electronic Protection Unit | 5 | Nos | |
2822 | 49.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2823 | 49.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2824 | 49.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2825 | 49.46 | Replacement of MCCB | 1 | Nos | |
2826 | 49.47 | Replacement of Power Diode | 1 | Nos | |
2827 | 49.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2828 | 49.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2829 | 49.5 | Replacement of Overload Relay | 12 | Nos | |
2830 | 49.51 | Replacement of Coils | 1 | Nos | |
2831 | 49.52 | Replacement of Voltage Relays | 1 | Nos | |
2832 | 49.53 | Replacement of ON/OFF Stage Over Switch | 8 | Nos | |
2833 | 49.54 | Renewal of 3 Core Cable | 1 | Nos | |
2834 | 49.55 | Replacement of Control Transformers | 1 | Nos | |
2835 | 49.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2836 | 49.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2837 | 49.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2838 | 49.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2839 | 49.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2840 | 49.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2841 | 49.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2842 | 49.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2843 | 49.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
2844 | 49.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2845 | 50 | 20.1-30A | |||
2846 | 50.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 2 | Nos | |
2847 | 50.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2848 | 50.03 | Calibration of O/L Relay | 1 | Nos | |
2849 | 50.04 | Repair of Coils | 1 | Nos | |
2850 | 50.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
2851 | 50.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
2852 | 50.07 | Replacement of Push Button switches | 1 | Nos | |
2853 | 50.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 5 | Nos | |
2854 | 50.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2855 | 50.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2856 | 50.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2857 | 50.12 | Repair of Control Transformers | 1 | Nos | |
2858 | 50.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2859 | 50.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2860 | 50.15 | Replacement of Control Fuses | 2 | Nos | |
2861 | 50.16 | Replacement of time delay relay | 1 | Nos | |
2862 | 50.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2863 | 50.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2864 | 50.19 | Replacement of Rotary Switches | 1 | Nos | |
2865 | 50.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2866 | 50.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
2867 | 50.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 2 | Nos | |
2868 | 50.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2869 | 50.24 | Replacement of Lock Pins | 1 | Nos | |
2870 | 50.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2871 | 50.26 | Replacement of Ebonite Board | 1 | Nos | |
2872 | 50.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2873 | 50.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2874 | 50.29 | Replacement of Wire Wound Resistors | 2 | Nos | |
2875 | 50.3 | Replacement of Change Over Handle | 1 | Nos | |
2876 | 50.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2877 | 50.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2878 | 50.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2879 | 50.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2880 | 50.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2881 | 50.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
2882 | 50.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2883 | 50.38 | Painting | 1 | Nos | |
2884 | 50.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2885 | 50.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2886 | 50.41 | Repair of Electronic Protection Unit | 1 | Nos | |
2887 | 50.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2888 | 50.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2889 | 50.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2890 | 50.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2891 | 50.46 | Replacement of MCCB | 1 | Nos | |
2892 | 50.47 | Replacement of Power Diode | 1 | Nos | |
2893 | 50.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2894 | 50.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2895 | 50.5 | Replacement of Overload Relay | 2 | Nos | |
2896 | 50.51 | Replacement of Coils | 1 | Nos | |
2897 | 50.52 | Replacement of Voltage Relays | 1 | Nos | |
2898 | 50.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
2899 | 50.54 | Renewal of 3 Core Cable | 1 | Nos | |
2900 | 50.55 | Replacement of Control Transformers | 1 | Nos | |
2901 | 50.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2902 | 50.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2903 | 50.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2904 | 50.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2905 | 50.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2906 | 50.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2907 | 50.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2908 | 50.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2909 | 50.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
2910 | 50.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
2911 | 51 | 30.1-50A | |||
2912 | 51.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 8 | Nos | |
2913 | 51.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2914 | 51.03 | Calibration of O/L Relay | 1 | Nos | |
2915 | 51.04 | Repair of Coils | 1 | Nos | |
2916 | 51.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 3 | Nos | |
2917 | 51.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
2918 | 51.07 | Replacement of Push Button switches | 1 | Nos | |
2919 | 51.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 15 | Nos | |
2920 | 51.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2921 | 51.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2922 | 51.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2923 | 51.12 | Repair of Control Transformers | 1 | Nos | |
2924 | 51.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2925 | 51.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2926 | 51.15 | Replacement of Control Fuses | 14 | Nos | |
2927 | 51.16 | Replacement of time delay relay | 3 | Nos | |
2928 | 51.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
2929 | 51.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2930 | 51.19 | Replacement of Rotary Switches | 1 | Nos | |
2931 | 51.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2932 | 51.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
2933 | 51.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 24 | Nos | |
2934 | 51.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
2935 | 51.24 | Replacement of Lock Pins | 1 | Nos | |
2936 | 51.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
2937 | 51.26 | Replacement of Ebonite Board | 1 | Nos | |
2938 | 51.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
2939 | 51.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
2940 | 51.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
2941 | 51.3 | Replacement of Change Over Handle | 1 | Nos | |
2942 | 51.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
2943 | 51.32 | Repair of 3 Ph 4 Way Rotary Switch | 4 | Nos | |
2944 | 51.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
2945 | 51.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
2946 | 51.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
2947 | 51.36 | Replacement of NO/NC Auxiliary Contacts | 7 | Nos | |
2948 | 51.37 | Repair of Amp/Volt Meter | 1 | Nos | |
2949 | 51.38 | Painting | 1 | Nos | |
2950 | 51.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2951 | 51.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
2952 | 51.41 | Repair of Electronic Protection Unit | 2 | Nos | |
2953 | 51.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
2954 | 51.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
2955 | 51.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
2956 | 51.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
2957 | 51.46 | Replacement of MCCB | 1 | Nos | |
2958 | 51.47 | Replacement of Power Diode | 20 | Nos | |
2959 | 51.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
2960 | 51.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
2961 | 51.5 | Replacement of Overload Relay | 2 | Nos | |
2962 | 51.51 | Replacement of Coils | 3 | Nos | |
2963 | 51.52 | Replacement of Voltage Relays | 6 | Nos | |
2964 | 51.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
2965 | 51.54 | Renewal of 3 Core Cable | 1 | Nos | |
2966 | 51.55 | Replacement of Control Transformers | 1 | Nos | |
2967 | 51.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
2968 | 51.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
2969 | 51.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
2970 | 51.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
2971 | 51.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2972 | 51.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2973 | 51.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2974 | 51.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
2975 | 51.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 6 | Nos | |
2976 | 51.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
2977 | 52 | 50.1-75A | |||
2978 | 52.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 7 | Nos | |
2979 | 52.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
2980 | 52.03 | Calibration of O/L Relay | 1 | Nos | |
2981 | 52.04 | Repair of Coils | 1 | Nos | |
2982 | 52.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
2983 | 52.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 4 | Nos | |
2984 | 52.07 | Replacement of Push Button switches | 1 | Nos | |
2985 | 52.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 40 | Nos | |
2986 | 52.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
2987 | 52.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
2988 | 52.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
2989 | 52.12 | Repair of Control Transformers | 1 | Nos | |
2990 | 52.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2991 | 52.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
2992 | 52.15 | Replacement of Control Fuses | 20 | Nos | |
2993 | 52.16 | Replacement of time delay relay | 1 | Nos | |
2994 | 52.17 | Replacement of Indication Lamps and Holders | 3 | Nos | |
2995 | 52.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
2996 | 52.19 | Replacement of Rotary Switches | 1 | Nos | |
2997 | 52.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
2998 | 52.21 | Replacement of Bakelite Moulding Rate/MM | 9 | Nos | |
2999 | 52.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 18 | Nos | |
3000 | 52.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3001 | 52.24 | Replacement of Lock Pins | 1 | Nos | |
3002 | 52.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3003 | 52.26 | Replacement of Ebonite Board | 1 | Nos | |
3004 | 52.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3005 | 52.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3006 | 52.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
3007 | 52.3 | Replacement of Change Over Handle | 1 | Nos | |
3008 | 52.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
3009 | 52.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3010 | 52.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3011 | 52.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3012 | 52.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3013 | 52.36 | Replacement of NO/NC Auxiliary Contacts | 13 | Nos | |
3014 | 52.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3015 | 52.38 | Painting | 1 | Nos | |
3016 | 52.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3017 | 52.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3018 | 52.41 | Repair of Electronic Protection Unit | 3 | Nos | |
3019 | 52.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
3020 | 52.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3021 | 52.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3022 | 52.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3023 | 52.46 | Replacement of MCCB | 1 | Nos | |
3024 | 52.47 | Replacement of Power Diode | 5 | Nos | |
3025 | 52.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3026 | 52.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3027 | 52.5 | Replacement of Overload Relay | 1 | Nos | |
3028 | 52.51 | Replacement of Coils | 1 | Nos | |
3029 | 52.52 | Replacement of Voltage Relays | 3 | Nos | |
3030 | 52.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
3031 | 52.54 | Renewal of 3 Core Cable | 1 | Nos | |
3032 | 52.55 | Replacement of Control Transformers | 1 | Nos | |
3033 | 52.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3034 | 52.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3035 | 52.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3036 | 52.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3037 | 52.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3038 | 52.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3039 | 52.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3040 | 52.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3041 | 52.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
3042 | 52.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3043 | 53 | 75.1-100A | |||
3044 | 53.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 9 | Nos | |
3045 | 53.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3046 | 53.03 | Calibration of O/L Relay | 1 | Nos | |
3047 | 53.04 | Repair of Coils | 1 | Nos | |
3048 | 53.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 4 | Nos | |
3049 | 53.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
3050 | 53.07 | Replacement of Push Button switches | 1 | Nos | |
3051 | 53.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 25 | Nos | |
3052 | 53.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3053 | 53.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3054 | 53.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3055 | 53.12 | Repair of Control Transformers | 1 | Nos | |
3056 | 53.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3057 | 53.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3058 | 53.15 | Replacement of Control Fuses | 17 | Nos | |
3059 | 53.16 | Replacement of time delay relay | 4 | Nos | |
3060 | 53.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3061 | 53.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3062 | 53.19 | Replacement of Rotary Switches | 1 | Nos | |
3063 | 53.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3064 | 53.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
3065 | 53.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 27 | Nos | |
3066 | 53.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3067 | 53.24 | Replacement of Lock Pins | 1 | Nos | |
3068 | 53.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3069 | 53.26 | Replacement of Ebonite Board | 1 | Nos | |
3070 | 53.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 9 | Nos | |
3071 | 53.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3072 | 53.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
3073 | 53.3 | Replacement of Change Over Handle | 1 | Nos | |
3074 | 53.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3075 | 53.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3076 | 53.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3077 | 53.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3078 | 53.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3079 | 53.36 | Replacement of NO/NC Auxiliary Contacts | 10 | Nos | |
3080 | 53.37 | Repair of Amp/Volt Meter | 2 | Nos | |
3081 | 53.38 | Painting | 1 | Nos | |
3082 | 53.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3083 | 53.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3084 | 53.41 | Repair of Electronic Protection Unit | 1 | Nos | |
3085 | 53.42 | Replacement of Electronic Protection Unit | 2 | Nos | |
3086 | 53.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3087 | 53.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3088 | 53.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3089 | 53.46 | Replacement of MCCB | 1 | Nos | |
3090 | 53.47 | Replacement of Power Diode | 18 | Nos | |
3091 | 53.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3092 | 53.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3093 | 53.5 | Replacement of Overload Relay | 3 | Nos | |
3094 | 53.51 | Replacement of Coils | 3 | Nos | |
3095 | 53.52 | Replacement of Voltage Relays | 6 | Nos | |
3096 | 53.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
3097 | 53.54 | Renewal of 3 Core Cable | 1 | Nos | |
3098 | 53.55 | Replacement of Control Transformers | 1 | Nos | |
3099 | 53.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3100 | 53.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3101 | 53.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3102 | 53.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3103 | 53.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3104 | 53.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3105 | 53.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3106 | 53.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3107 | 53.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
3108 | 53.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 3 | Nos | |
3109 | 54 | 100.1-150A | |||
3110 | 54.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 21 | Nos | |
3111 | 54.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3112 | 54.03 | Calibration of O/L Relay | 1 | Nos | |
3113 | 54.04 | Repair of Coils | 1 | Nos | |
3114 | 54.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 5 | Nos | |
3115 | 54.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
3116 | 54.07 | Replacement of Push Button switches | 1 | Nos | |
3117 | 54.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 79 | Nos | |
3118 | 54.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3119 | 54.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 2 | Nos | |
3120 | 54.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3121 | 54.12 | Repair of Control Transformers | 1 | Nos | |
3122 | 54.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3123 | 54.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
3124 | 54.15 | Replacement of Control Fuses | 43 | Nos | |
3125 | 54.16 | Replacement of time delay relay | 16 | Nos | |
3126 | 54.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3127 | 54.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3128 | 54.19 | Replacement of Rotary Switches | 1 | Nos | |
3129 | 54.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3130 | 54.21 | Replacement of Bakelite Moulding Rate/MM | 15 | Nos | |
3131 | 54.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 61 | Nos | |
3132 | 54.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 4 | Nos | |
3133 | 54.24 | Replacement of Lock Pins | 1 | Nos | |
3134 | 54.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3135 | 54.26 | Replacement of Ebonite Board | 1 | Nos | |
3136 | 54.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 10 | Nos | |
3137 | 54.28 | Replacement of Bakelite Switches and Knobs | 2 | Nos | |
3138 | 54.29 | Replacement of Wire Wound Resistors | 67 | Nos | |
3139 | 54.3 | Replacement of Change Over Handle | 1 | Nos | |
3140 | 54.31 | Repair of Single Phase Protection Unit | 3 | Nos | |
3141 | 54.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3142 | 54.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3143 | 54.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3144 | 54.35 | Replacement of Rubber Beading of Starter (Gasket) | 2 | Nos | |
3145 | 54.36 | Replacement of NO/NC Auxiliary Contacts | 51 | Nos | |
3146 | 54.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3147 | 54.38 | Painting | 1 | Nos | |
3148 | 54.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3149 | 54.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3150 | 54.41 | Repair of Electronic Protection Unit | 1 | Nos | |
3151 | 54.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
3152 | 54.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3153 | 54.44 | Replacement of TPU (Thermal Power Unit) | 4 | Nos | |
3154 | 54.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 12 | Nos | |
3155 | 54.46 | Replacement of MCCB | 1 | Nos | |
3156 | 54.47 | Replacement of Power Diode | 94 | Nos | |
3157 | 54.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 3 | Nos | |
3158 | 54.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3159 | 54.5 | Replacement of Overload Relay | 4 | Nos | |
3160 | 54.51 | Replacement of Coils | 9 | Nos | |
3161 | 54.52 | Replacement of Voltage Relays | 9 | Nos | |
3162 | 54.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
3163 | 54.54 | Renewal of 3 Core Cable | 1 | Nos | |
3164 | 54.55 | Replacement of Control Transformers | 1 | Nos | |
3165 | 54.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3166 | 54.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3167 | 54.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3168 | 54.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3169 | 54.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3170 | 54.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3171 | 54.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3172 | 54.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3173 | 54.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 9 | Nos | |
3174 | 54.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 4 | Nos | |
3175 | 55 | 150.1-200A | |||
3176 | 55.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
3177 | 55.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3178 | 55.03 | Calibration of O/L Relay | 1 | Nos | |
3179 | 55.04 | Repair of Coils | 1 | Nos | |
3180 | 55.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
3181 | 55.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
3182 | 55.07 | Replacement of Push Button switches | 1 | Nos | |
3183 | 55.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 10 | Nos | |
3184 | 55.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3185 | 55.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3186 | 55.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3187 | 55.12 | Repair of Control Transformers | 1 | Nos | |
3188 | 55.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3189 | 55.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3190 | 55.15 | Replacement of Control Fuses | 6 | Nos | |
3191 | 55.16 | Replacement of time delay relay | 3 | Nos | |
3192 | 55.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3193 | 55.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3194 | 55.19 | Replacement of Rotary Switches | 1 | Nos | |
3195 | 55.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3196 | 55.21 | Replacement of Bakelite Moulding Rate/MM | 2 | Nos | |
3197 | 55.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 21 | Nos | |
3198 | 55.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3199 | 55.24 | Replacement of Lock Pins | 1 | Nos | |
3200 | 55.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3201 | 55.26 | Replacement of Ebonite Board | 1 | Nos | |
3202 | 55.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3203 | 55.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3204 | 55.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
3205 | 55.3 | Replacement of Change Over Handle | 1 | Nos | |
3206 | 55.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3207 | 55.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3208 | 55.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3209 | 55.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3210 | 55.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3211 | 55.36 | Replacement of NO/NC Auxiliary Contacts | 6 | Nos | |
3212 | 55.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3213 | 55.38 | Painting | 1 | Nos | |
3214 | 55.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3215 | 55.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3216 | 55.41 | Repair of Electronic Protection Unit | 1 | Nos | |
3217 | 55.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
3218 | 55.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3219 | 55.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3220 | 55.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 2 | Nos | |
3221 | 55.46 | Replacement of MCCB | 1 | Nos | |
3222 | 55.47 | Replacement of Power Diode | 4 | Nos | |
3223 | 55.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3224 | 55.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3225 | 55.5 | Replacement of Overload Relay | 1 | Nos | |
3226 | 55.51 | Replacement of Coils | 1 | Nos | |
3227 | 55.52 | Replacement of Voltage Relays | 3 | Nos | |
3228 | 55.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
3229 | 55.54 | Renewal of 3 Core Cable | 1 | Nos | |
3230 | 55.55 | Replacement of Control Transformers | 1 | Nos | |
3231 | 55.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3232 | 55.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3233 | 55.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3234 | 55.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3235 | 55.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3236 | 55.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3237 | 55.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3238 | 55.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3239 | 55.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 2 | Nos | |
3240 | 55.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
3241 | 56 | 200.1-300A | |||
3242 | 56.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
3243 | 56.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3244 | 56.03 | Calibration of O/L Relay | 1 | Nos | |
3245 | 56.04 | Repair of Coils | 1 | Nos | |
3246 | 56.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
3247 | 56.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
3248 | 56.07 | Replacement of Push Button switches | 1 | Nos | |
3249 | 56.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 17 | Nos | |
3250 | 56.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3251 | 56.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3252 | 56.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3253 | 56.12 | Repair of Control Transformers | 1 | Nos | |
3254 | 56.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3255 | 56.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3256 | 56.15 | Replacement of Control Fuses | 7 | Nos | |
3257 | 56.16 | Replacement of time delay relay | 3 | Nos | |
3258 | 56.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3259 | 56.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3260 | 56.19 | Replacement of Rotary Switches | 1 | Nos | |
3261 | 56.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3262 | 56.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
3263 | 56.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 17 | Nos | |
3264 | 56.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3265 | 56.24 | Replacement of Lock Pins | 1 | Nos | |
3266 | 56.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3267 | 56.26 | Replacement of Ebonite Board | 1 | Nos | |
3268 | 56.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3269 | 56.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3270 | 56.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
3271 | 56.3 | Replacement of Change Over Handle | 1 | Nos | |
3272 | 56.31 | Repair of Single Phase Protection Unit | 2 | Nos | |
3273 | 56.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3274 | 56.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3275 | 56.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3276 | 56.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3277 | 56.36 | Replacement of NO/NC Auxiliary Contacts | 11 | Nos | |
3278 | 56.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3279 | 56.38 | Painting | 1 | Nos | |
3280 | 56.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3281 | 56.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3282 | 56.41 | Repair of Electronic Protection Unit | 1 | Nos | |
3283 | 56.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
3284 | 56.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3285 | 56.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3286 | 56.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3287 | 56.46 | Replacement of MCCB | 1 | Nos | |
3288 | 56.47 | Replacement of Power Diode | 4 | Nos | |
3289 | 56.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3290 | 56.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3291 | 56.5 | Replacement of Overload Relay | 1 | Nos | |
3292 | 56.51 | Replacement of Coils | 1 | Nos | |
3293 | 56.52 | Replacement of Voltage Relays | 5 | Nos | |
3294 | 56.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
3295 | 56.54 | Renewal of 3 Core Cable | 1 | Nos | |
3296 | 56.55 | Replacement of Control Transformers | 1 | Nos | |
3297 | 56.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3298 | 56.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3299 | 56.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3300 | 56.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3301 | 56.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3302 | 56.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3303 | 56.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3304 | 56.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3305 | 56.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
3306 | 56.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3307 | 57 | 300.1-500A | |||
3308 | 57.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
3309 | 57.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3310 | 57.03 | Calibration of O/L Relay | 1 | Nos | |
3311 | 57.04 | Repair of Coils | 1 | Nos | |
3312 | 57.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
3313 | 57.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
3314 | 57.07 | Replacement of Push Button switches | 1 | Nos | |
3315 | 57.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
3316 | 57.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3317 | 57.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3318 | 57.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3319 | 57.12 | Repair of Control Transformers | 1 | Nos | |
3320 | 57.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3321 | 57.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3322 | 57.15 | Replacement of Control Fuses | 1 | Nos | |
3323 | 57.16 | Replacement of time delay relay | 1 | Nos | |
3324 | 57.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3325 | 57.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3326 | 57.19 | Replacement of Rotary Switches | 1 | Nos | |
3327 | 57.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3328 | 57.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
3329 | 57.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 40 | Nos | |
3330 | 57.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3331 | 57.24 | Replacement of Lock Pins | 1 | Nos | |
3332 | 57.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3333 | 57.26 | Replacement of Ebonite Board | 1 | Nos | |
3334 | 57.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3335 | 57.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3336 | 57.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
3337 | 57.3 | Replacement of Change Over Handle | 1 | Nos | |
3338 | 57.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3339 | 57.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3340 | 57.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3341 | 57.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3342 | 57.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3343 | 57.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
3344 | 57.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3345 | 57.38 | Painting | 1 | Nos | |
3346 | 57.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3347 | 57.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3348 | 57.41 | Repair of Electronic Protection Unit | 1 | Nos | |
3349 | 57.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
3350 | 57.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3351 | 57.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3352 | 57.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3353 | 57.46 | Replacement of MCCB | 1 | Nos | |
3354 | 57.47 | Replacement of Power Diode | 1 | Nos | |
3355 | 57.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3356 | 57.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3357 | 57.5 | Replacement of Overload Relay | 1 | Nos | |
3358 | 57.51 | Replacement of Coils | 1 | Nos | |
3359 | 57.52 | Replacement of Voltage Relays | 1 | Nos | |
3360 | 57.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
3361 | 57.54 | Renewal of 3 Core Cable | 1 | Nos | |
3362 | 57.55 | Replacement of Control Transformers | 1 | Nos | |
3363 | 57.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3364 | 57.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3365 | 57.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3366 | 57.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3367 | 57.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3368 | 57.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3369 | 57.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3370 | 57.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3371 | 57.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
3372 | 57.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3373 | 58 | 500.1-600A | |||
3374 | 58.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
3375 | 58.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3376 | 58.03 | Calibration of O/L Relay | 1 | Nos | |
3377 | 58.04 | Repair of Coils | 1 | Nos | |
3378 | 58.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
3379 | 58.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
3380 | 58.07 | Replacement of Push Button switches | 1 | Nos | |
3381 | 58.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
3382 | 58.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3383 | 58.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3384 | 58.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3385 | 58.12 | Repair of Control Transformers | 1 | Nos | |
3386 | 58.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3387 | 58.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3388 | 58.15 | Replacement of Control Fuses | 1 | Nos | |
3389 | 58.16 | Replacement of time delay relay | 1 | Nos | |
3390 | 58.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3391 | 58.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3392 | 58.19 | Replacement of Rotary Switches | 1 | Nos | |
3393 | 58.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3394 | 58.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
3395 | 58.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 3 | Nos | |
3396 | 58.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3397 | 58.24 | Replacement of Lock Pins | 1 | Nos | |
3398 | 58.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3399 | 58.26 | Replacement of Ebonite Board | 1 | Nos | |
3400 | 58.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3401 | 58.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3402 | 58.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
3403 | 58.3 | Replacement of Change Over Handle | 1 | Nos | |
3404 | 58.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3405 | 58.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3406 | 58.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3407 | 58.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3408 | 58.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3409 | 58.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
3410 | 58.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3411 | 58.38 | Painting | 1 | Nos | |
3412 | 58.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3413 | 58.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3414 | 58.41 | Repair of Electronic Protection Unit | 1 | Nos | |
3415 | 58.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
3416 | 58.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3417 | 58.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3418 | 58.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3419 | 58.46 | Replacement of MCCB | 1 | Nos | |
3420 | 58.47 | Replacement of Power Diode | 1 | Nos | |
3421 | 58.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3422 | 58.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3423 | 58.5 | Replacement of Overload Relay | 1 | Nos | |
3424 | 58.51 | Replacement of Coils | 1 | Nos | |
3425 | 58.52 | Replacement of Voltage Relays | 1 | Nos | |
3426 | 58.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
3427 | 58.54 | Renewal of 3 Core Cable | 1 | Nos | |
3428 | 58.55 | Replacement of Control Transformers | 1 | Nos | |
3429 | 58.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3430 | 58.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3431 | 58.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3432 | 58.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3433 | 58.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3434 | 58.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3435 | 58.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3436 | 58.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3437 | 58.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
3438 | 58.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3439 | 59 | THIRD YEAR | |||
3440 | 60 | SERVICES | |||
3441 | 61 | 5A | |||
3442 | 61.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
3443 | 61.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3444 | 61.03 | Calibration of O/L Relay | 1 | Nos | |
3445 | 61.04 | Repair of Coils | 1 | Nos | |
3446 | 61.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
3447 | 61.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
3448 | 61.07 | Replacement of Push Button switches | 1 | Nos | |
3449 | 61.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
3450 | 61.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3451 | 61.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3452 | 61.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3453 | 61.12 | Repair of Control Transformers | 1 | Nos | |
3454 | 61.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3455 | 61.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3456 | 61.15 | Replacement of Control Fuses | 1 | Nos | |
3457 | 61.16 | Replacement of time delay relay | 1 | Nos | |
3458 | 61.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3459 | 61.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3460 | 61.19 | Replacement of Rotary Switches | 1 | Nos | |
3461 | 61.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3462 | 61.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
3463 | 61.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
3464 | 61.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3465 | 61.24 | Replacement of Lock Pins | 1 | Nos | |
3466 | 61.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3467 | 61.26 | Replacement of Ebonite Board | 1 | Nos | |
3468 | 61.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3469 | 61.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3470 | 61.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
3471 | 61.3 | Replacement of Change Over Handle | 1 | Nos | |
3472 | 61.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3473 | 61.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3474 | 61.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3475 | 61.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3476 | 61.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3477 | 61.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
3478 | 61.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3479 | 61.38 | Painting | 1 | Nos | |
3480 | 61.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3481 | 61.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3482 | 61.41 | Repair of Electronic Protection Unit | 1 | Nos | |
3483 | 61.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
3484 | 61.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3485 | 61.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3486 | 61.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3487 | 61.46 | Replacement of MCCB | 1 | Nos | |
3488 | 61.47 | Replacement of Power Diode | 1 | Nos | |
3489 | 61.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3490 | 61.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3491 | 61.5 | Replacement of Overload Relay | 1 | Nos | |
3492 | 61.51 | Replacement of Coils | 1 | Nos | |
3493 | 61.52 | Replacement of Voltage Relays | 1 | Nos | |
3494 | 61.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
3495 | 61.54 | Renewal of 3 Core Cable | 1 | Nos | |
3496 | 61.55 | Replacement of Control Transformers | 1 | Nos | |
3497 | 61.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3498 | 61.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3499 | 61.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3500 | 61.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3501 | 61.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3502 | 61.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3503 | 61.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3504 | 61.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3505 | 61.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
3506 | 61.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3507 | 62 | 5.1-10A | |||
3508 | 62.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
3509 | 62.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3510 | 62.03 | Calibration of O/L Relay | 1 | Nos | |
3511 | 62.04 | Repair of Coils | 1 | Nos | |
3512 | 62.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
3513 | 62.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
3514 | 62.07 | Replacement of Push Button switches | 1 | Nos | |
3515 | 62.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 7 | Nos | |
3516 | 62.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3517 | 62.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3518 | 62.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3519 | 62.12 | Repair of Control Transformers | 1 | Nos | |
3520 | 62.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3521 | 62.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3522 | 62.15 | Replacement of Control Fuses | 13 | Nos | |
3523 | 62.16 | Replacement of time delay relay | 1 | Nos | |
3524 | 62.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3525 | 62.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3526 | 62.19 | Replacement of Rotary Switches | 1 | Nos | |
3527 | 62.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3528 | 62.21 | Replacement of Bakelite Moulding Rate/MM | 10 | Nos | |
3529 | 62.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
3530 | 62.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3531 | 62.24 | Replacement of Lock Pins | 1 | Nos | |
3532 | 62.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3533 | 62.26 | Replacement of Ebonite Board | 1 | Nos | |
3534 | 62.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3535 | 62.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3536 | 62.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
3537 | 62.3 | Replacement of Change Over Handle | 1 | Nos | |
3538 | 62.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3539 | 62.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3540 | 62.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3541 | 62.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3542 | 62.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3543 | 62.36 | Replacement of NO/NC Auxiliary Contacts | 2 | Nos | |
3544 | 62.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3545 | 62.38 | Painting | 1 | Nos | |
3546 | 62.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3547 | 62.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3548 | 62.41 | Repair of Electronic Protection Unit | 2 | Nos | |
3549 | 62.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
3550 | 62.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3551 | 62.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3552 | 62.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3553 | 62.46 | Replacement of MCCB | 1 | Nos | |
3554 | 62.47 | Replacement of Power Diode | 1 | Nos | |
3555 | 62.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3556 | 62.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3557 | 62.5 | Replacement of Overload Relay | 6 | Nos | |
3558 | 62.51 | Replacement of Coils | 1 | Nos | |
3559 | 62.52 | Replacement of Voltage Relays | 1 | Nos | |
3560 | 62.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
3561 | 62.54 | Renewal of 3 Core Cable | 1 | Nos | |
3562 | 62.55 | Replacement of Control Transformers | 1 | Nos | |
3563 | 62.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3564 | 62.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3565 | 62.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3566 | 62.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3567 | 62.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3568 | 62.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3569 | 62.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3570 | 62.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3571 | 62.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
3572 | 62.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3573 | 63 | 10.1-15A | |||
3574 | 63.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 58 | Nos | |
3575 | 63.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3576 | 63.03 | Calibration of O/L Relay | 1 | Nos | |
3577 | 63.04 | Repair of Coils | 1 | Nos | |
3578 | 63.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 7 | Nos | |
3579 | 63.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 47 | Nos | |
3580 | 63.07 | Replacement of Push Button switches | 1 | Nos | |
3581 | 63.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 38 | Nos | |
3582 | 63.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 5 | Nos | |
3583 | 63.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3584 | 63.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3585 | 63.12 | Repair of Control Transformers | 2 | Nos | |
3586 | 63.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
3587 | 63.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3588 | 63.15 | Replacement of Control Fuses | 99 | Nos | |
3589 | 63.16 | Replacement of time delay relay | 6 | Nos | |
3590 | 63.17 | Replacement of Indication Lamps and Holders | 6 | Nos | |
3591 | 63.18 | Replacement of ON/OFF Push Units | 2 | Nos | |
3592 | 63.19 | Replacement of Rotary Switches | 1 | Nos | |
3593 | 63.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3594 | 63.21 | Replacement of Bakelite Moulding Rate/MM | 7 | Nos | |
3595 | 63.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
3596 | 63.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3597 | 63.24 | Replacement of Lock Pins | 1 | Nos | |
3598 | 63.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3599 | 63.26 | Replacement of Ebonite Board | 1 | Nos | |
3600 | 63.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3601 | 63.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3602 | 63.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
3603 | 63.3 | Replacement of Change Over Handle | 1 | Nos | |
3604 | 63.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
3605 | 63.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3606 | 63.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3607 | 63.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3608 | 63.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3609 | 63.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
3610 | 63.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3611 | 63.38 | Painting | 1 | Nos | |
3612 | 63.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3613 | 63.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3614 | 63.41 | Repair of Electronic Protection Unit | 5 | Nos | |
3615 | 63.42 | Replacement of Electronic Protection Unit | 26 | Nos | |
3616 | 63.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3617 | 63.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3618 | 63.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3619 | 63.46 | Replacement of MCCB | 1 | Nos | |
3620 | 63.47 | Replacement of Power Diode | 1 | Nos | |
3621 | 63.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3622 | 63.49 | Replacement of Socket (Brass & Ebonite) | 2 | Nos | |
3623 | 63.5 | Replacement of Overload Relay | 53 | Nos | |
3624 | 63.51 | Replacement of Coils | 3 | Nos | |
3625 | 63.52 | Replacement of Voltage Relays | 2 | Nos | |
3626 | 63.53 | Replacement of ON/OFF Stage Over Switch | 21 | Nos | |
3627 | 63.54 | Renewal of 3 Core Cable | 1 | Nos | |
3628 | 63.55 | Replacement of Control Transformers | 1 | Nos | |
3629 | 63.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3630 | 63.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3631 | 63.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3632 | 63.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3633 | 63.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3634 | 63.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3635 | 63.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3636 | 63.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3637 | 63.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
3638 | 63.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3639 | 64 | 15.1-20A | |||
3640 | 64.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 14 | Nos | |
3641 | 64.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3642 | 64.03 | Calibration of O/L Relay | 1 | Nos | |
3643 | 64.04 | Repair of Coils | 1 | Nos | |
3644 | 64.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
3645 | 64.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 11 | Nos | |
3646 | 64.07 | Replacement of Push Button switches | 1 | Nos | |
3647 | 64.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 3 | Nos | |
3648 | 64.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3649 | 64.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3650 | 64.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3651 | 64.12 | Repair of Control Transformers | 1 | Nos | |
3652 | 64.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 2 | Nos | |
3653 | 64.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3654 | 64.15 | Replacement of Control Fuses | 25 | Nos | |
3655 | 64.16 | Replacement of time delay relay | 4 | Nos | |
3656 | 64.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3657 | 64.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3658 | 64.19 | Replacement of Rotary Switches | 1 | Nos | |
3659 | 64.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3660 | 64.21 | Replacement of Bakelite Moulding Rate/MM | 8 | Nos | |
3661 | 64.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
3662 | 64.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3663 | 64.24 | Replacement of Lock Pins | 1 | Nos | |
3664 | 64.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3665 | 64.26 | Replacement of Ebonite Board | 1 | Nos | |
3666 | 64.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3667 | 64.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3668 | 64.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
3669 | 64.3 | Replacement of Change Over Handle | 1 | Nos | |
3670 | 64.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3671 | 64.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3672 | 64.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3673 | 64.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3674 | 64.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3675 | 64.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
3676 | 64.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3677 | 64.38 | Painting | 2 | Nos | |
3678 | 64.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3679 | 64.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3680 | 64.41 | Repair of Electronic Protection Unit | 2 | Nos | |
3681 | 64.42 | Replacement of Electronic Protection Unit | 5 | Nos | |
3682 | 64.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3683 | 64.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3684 | 64.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3685 | 64.46 | Replacement of MCCB | 1 | Nos | |
3686 | 64.47 | Replacement of Power Diode | 1 | Nos | |
3687 | 64.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3688 | 64.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3689 | 64.5 | Replacement of Overload Relay | 12 | Nos | |
3690 | 64.51 | Replacement of Coils | 1 | Nos | |
3691 | 64.52 | Replacement of Voltage Relays | 1 | Nos | |
3692 | 64.53 | Replacement of ON/OFF Stage Over Switch | 8 | Nos | |
3693 | 64.54 | Renewal of 3 Core Cable | 1 | Nos | |
3694 | 64.55 | Replacement of Control Transformers | 1 | Nos | |
3695 | 64.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3696 | 64.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3697 | 64.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3698 | 64.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3699 | 64.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3700 | 64.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3701 | 64.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3702 | 64.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3703 | 64.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
3704 | 64.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3705 | 65 | 20.1-30A | |||
3706 | 65.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 2 | Nos | |
3707 | 65.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3708 | 65.03 | Calibration of O/L Relay | 1 | Nos | |
3709 | 65.04 | Repair of Coils | 1 | Nos | |
3710 | 65.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
3711 | 65.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
3712 | 65.07 | Replacement of Push Button switches | 1 | Nos | |
3713 | 65.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 5 | Nos | |
3714 | 65.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3715 | 65.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3716 | 65.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3717 | 65.12 | Repair of Control Transformers | 1 | Nos | |
3718 | 65.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3719 | 65.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3720 | 65.15 | Replacement of Control Fuses | 2 | Nos | |
3721 | 65.16 | Replacement of time delay relay | 1 | Nos | |
3722 | 65.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3723 | 65.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3724 | 65.19 | Replacement of Rotary Switches | 1 | Nos | |
3725 | 65.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3726 | 65.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
3727 | 65.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 2 | Nos | |
3728 | 65.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3729 | 65.24 | Replacement of Lock Pins | 1 | Nos | |
3730 | 65.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3731 | 65.26 | Replacement of Ebonite Board | 1 | Nos | |
3732 | 65.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3733 | 65.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3734 | 65.29 | Replacement of Wire Wound Resistors | 2 | Nos | |
3735 | 65.3 | Replacement of Change Over Handle | 1 | Nos | |
3736 | 65.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3737 | 65.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3738 | 65.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3739 | 65.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3740 | 65.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3741 | 65.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
3742 | 65.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3743 | 65.38 | Painting | 1 | Nos | |
3744 | 65.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3745 | 65.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3746 | 65.41 | Repair of Electronic Protection Unit | 1 | Nos | |
3747 | 65.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
3748 | 65.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3749 | 65.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3750 | 65.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3751 | 65.46 | Replacement of MCCB | 1 | Nos | |
3752 | 65.47 | Replacement of Power Diode | 1 | Nos | |
3753 | 65.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3754 | 65.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3755 | 65.5 | Replacement of Overload Relay | 2 | Nos | |
3756 | 65.51 | Replacement of Coils | 1 | Nos | |
3757 | 65.52 | Replacement of Voltage Relays | 1 | Nos | |
3758 | 65.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
3759 | 65.54 | Renewal of 3 Core Cable | 1 | Nos | |
3760 | 65.55 | Replacement of Control Transformers | 1 | Nos | |
3761 | 65.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3762 | 65.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3763 | 65.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3764 | 65.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3765 | 65.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3766 | 65.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3767 | 65.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3768 | 65.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3769 | 65.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
3770 | 65.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3771 | 66 | 30.1-50A | |||
3772 | 66.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 8 | Nos | |
3773 | 66.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3774 | 66.03 | Calibration of O/L Relay | 1 | Nos | |
3775 | 66.04 | Repair of Coils | 1 | Nos | |
3776 | 66.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 3 | Nos | |
3777 | 66.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
3778 | 66.07 | Replacement of Push Button switches | 1 | Nos | |
3779 | 66.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 15 | Nos | |
3780 | 66.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3781 | 66.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3782 | 66.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3783 | 66.12 | Repair of Control Transformers | 1 | Nos | |
3784 | 66.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3785 | 66.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3786 | 66.15 | Replacement of Control Fuses | 14 | Nos | |
3787 | 66.16 | Replacement of time delay relay | 3 | Nos | |
3788 | 66.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3789 | 66.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3790 | 66.19 | Replacement of Rotary Switches | 1 | Nos | |
3791 | 66.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3792 | 66.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
3793 | 66.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 24 | Nos | |
3794 | 66.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3795 | 66.24 | Replacement of Lock Pins | 1 | Nos | |
3796 | 66.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3797 | 66.26 | Replacement of Ebonite Board | 1 | Nos | |
3798 | 66.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3799 | 66.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3800 | 66.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
3801 | 66.3 | Replacement of Change Over Handle | 1 | Nos | |
3802 | 66.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3803 | 66.32 | Repair of 3 Ph 4 Way Rotary Switch | 4 | Nos | |
3804 | 66.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3805 | 66.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3806 | 66.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3807 | 66.36 | Replacement of NO/NC Auxiliary Contacts | 7 | Nos | |
3808 | 66.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3809 | 66.38 | Painting | 1 | Nos | |
3810 | 66.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3811 | 66.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3812 | 66.41 | Repair of Electronic Protection Unit | 2 | Nos | |
3813 | 66.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
3814 | 66.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3815 | 66.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3816 | 66.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3817 | 66.46 | Replacement of MCCB | 1 | Nos | |
3818 | 66.47 | Replacement of Power Diode | 20 | Nos | |
3819 | 66.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3820 | 66.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3821 | 66.5 | Replacement of Overload Relay | 2 | Nos | |
3822 | 66.51 | Replacement of Coils | 3 | Nos | |
3823 | 66.52 | Replacement of Voltage Relays | 6 | Nos | |
3824 | 66.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
3825 | 66.54 | Renewal of 3 Core Cable | 1 | Nos | |
3826 | 66.55 | Replacement of Control Transformers | 1 | Nos | |
3827 | 66.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3828 | 66.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3829 | 66.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3830 | 66.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3831 | 66.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3832 | 66.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3833 | 66.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3834 | 66.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3835 | 66.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 6 | Nos | |
3836 | 66.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
3837 | 67 | 50.1-75A | |||
3838 | 67.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 7 | Nos | |
3839 | 67.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3840 | 67.03 | Calibration of O/L Relay | 1 | Nos | |
3841 | 67.04 | Repair of Coils | 1 | Nos | |
3842 | 67.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
3843 | 67.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 4 | Nos | |
3844 | 67.07 | Replacement of Push Button switches | 1 | Nos | |
3845 | 67.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 40 | Nos | |
3846 | 67.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3847 | 67.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3848 | 67.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3849 | 67.12 | Repair of Control Transformers | 1 | Nos | |
3850 | 67.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3851 | 67.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3852 | 67.15 | Replacement of Control Fuses | 20 | Nos | |
3853 | 67.16 | Replacement of time delay relay | 1 | Nos | |
3854 | 67.17 | Replacement of Indication Lamps and Holders | 3 | Nos | |
3855 | 67.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3856 | 67.19 | Replacement of Rotary Switches | 1 | Nos | |
3857 | 67.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3858 | 67.21 | Replacement of Bakelite Moulding Rate/MM | 9 | Nos | |
3859 | 67.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 18 | Nos | |
3860 | 67.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3861 | 67.24 | Replacement of Lock Pins | 1 | Nos | |
3862 | 67.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3863 | 67.26 | Replacement of Ebonite Board | 1 | Nos | |
3864 | 67.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
3865 | 67.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3866 | 67.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
3867 | 67.3 | Replacement of Change Over Handle | 1 | Nos | |
3868 | 67.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
3869 | 67.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3870 | 67.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3871 | 67.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3872 | 67.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3873 | 67.36 | Replacement of NO/NC Auxiliary Contacts | 13 | Nos | |
3874 | 67.37 | Repair of Amp/Volt Meter | 1 | Nos | |
3875 | 67.38 | Painting | 1 | Nos | |
3876 | 67.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3877 | 67.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3878 | 67.41 | Repair of Electronic Protection Unit | 3 | Nos | |
3879 | 67.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
3880 | 67.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3881 | 67.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3882 | 67.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3883 | 67.46 | Replacement of MCCB | 1 | Nos | |
3884 | 67.47 | Replacement of Power Diode | 5 | Nos | |
3885 | 67.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3886 | 67.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3887 | 67.5 | Replacement of Overload Relay | 1 | Nos | |
3888 | 67.51 | Replacement of Coils | 1 | Nos | |
3889 | 67.52 | Replacement of Voltage Relays | 3 | Nos | |
3890 | 67.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
3891 | 67.54 | Renewal of 3 Core Cable | 1 | Nos | |
3892 | 67.55 | Replacement of Control Transformers | 1 | Nos | |
3893 | 67.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3894 | 67.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3895 | 67.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3896 | 67.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3897 | 67.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3898 | 67.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3899 | 67.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3900 | 67.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3901 | 67.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
3902 | 67.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
3903 | 68 | 75.1-100A | |||
3904 | 68.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 9 | Nos | |
3905 | 68.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3906 | 68.03 | Calibration of O/L Relay | 1 | Nos | |
3907 | 68.04 | Repair of Coils | 1 | Nos | |
3908 | 68.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 4 | Nos | |
3909 | 68.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
3910 | 68.07 | Replacement of Push Button switches | 1 | Nos | |
3911 | 68.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 25 | Nos | |
3912 | 68.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3913 | 68.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
3914 | 68.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3915 | 68.12 | Repair of Control Transformers | 1 | Nos | |
3916 | 68.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3917 | 68.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3918 | 68.15 | Replacement of Control Fuses | 17 | Nos | |
3919 | 68.16 | Replacement of time delay relay | 4 | Nos | |
3920 | 68.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3921 | 68.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3922 | 68.19 | Replacement of Rotary Switches | 1 | Nos | |
3923 | 68.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3924 | 68.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
3925 | 68.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 27 | Nos | |
3926 | 68.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
3927 | 68.24 | Replacement of Lock Pins | 1 | Nos | |
3928 | 68.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3929 | 68.26 | Replacement of Ebonite Board | 1 | Nos | |
3930 | 68.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 9 | Nos | |
3931 | 68.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
3932 | 68.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
3933 | 68.3 | Replacement of Change Over Handle | 1 | Nos | |
3934 | 68.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
3935 | 68.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3936 | 68.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
3937 | 68.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
3938 | 68.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
3939 | 68.36 | Replacement of NO/NC Auxiliary Contacts | 10 | Nos | |
3940 | 68.37 | Repair of Amp/Volt Meter | 2 | Nos | |
3941 | 68.38 | Painting | 1 | Nos | |
3942 | 68.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3943 | 68.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
3944 | 68.41 | Repair of Electronic Protection Unit | 1 | Nos | |
3945 | 68.42 | Replacement of Electronic Protection Unit | 2 | Nos | |
3946 | 68.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
3947 | 68.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
3948 | 68.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
3949 | 68.46 | Replacement of MCCB | 1 | Nos | |
3950 | 68.47 | Replacement of Power Diode | 18 | Nos | |
3951 | 68.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
3952 | 68.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
3953 | 68.5 | Replacement of Overload Relay | 3 | Nos | |
3954 | 68.51 | Replacement of Coils | 3 | Nos | |
3955 | 68.52 | Replacement of Voltage Relays | 6 | Nos | |
3956 | 68.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
3957 | 68.54 | Renewal of 3 Core Cable | 1 | Nos | |
3958 | 68.55 | Replacement of Control Transformers | 1 | Nos | |
3959 | 68.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
3960 | 68.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
3961 | 68.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
3962 | 68.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
3963 | 68.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3964 | 68.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3965 | 68.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3966 | 68.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
3967 | 68.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
3968 | 68.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 3 | Nos | |
3969 | 69 | 100.1-150A | |||
3970 | 69.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 21 | Nos | |
3971 | 69.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
3972 | 69.03 | Calibration of O/L Relay | 1 | Nos | |
3973 | 69.04 | Repair of Coils | 1 | Nos | |
3974 | 69.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 5 | Nos | |
3975 | 69.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
3976 | 69.07 | Replacement of Push Button switches | 1 | Nos | |
3977 | 69.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 79 | Nos | |
3978 | 69.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
3979 | 69.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 2 | Nos | |
3980 | 69.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
3981 | 69.12 | Repair of Control Transformers | 1 | Nos | |
3982 | 69.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
3983 | 69.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
3984 | 69.15 | Replacement of Control Fuses | 43 | Nos | |
3985 | 69.16 | Replacement of time delay relay | 16 | Nos | |
3986 | 69.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
3987 | 69.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
3988 | 69.19 | Replacement of Rotary Switches | 1 | Nos | |
3989 | 69.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
3990 | 69.21 | Replacement of Bakelite Moulding Rate/MM | 15 | Nos | |
3991 | 69.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 61 | Nos | |
3992 | 69.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 4 | Nos | |
3993 | 69.24 | Replacement of Lock Pins | 1 | Nos | |
3994 | 69.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
3995 | 69.26 | Replacement of Ebonite Board | 1 | Nos | |
3996 | 69.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 10 | Nos | |
3997 | 69.28 | Replacement of Bakelite Switches and Knobs | 2 | Nos | |
3998 | 69.29 | Replacement of Wire Wound Resistors | 67 | Nos | |
3999 | 69.3 | Replacement of Change Over Handle | 1 | Nos | |
4000 | 69.31 | Repair of Single Phase Protection Unit | 3 | Nos | |
4001 | 69.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4002 | 69.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4003 | 69.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4004 | 69.35 | Replacement of Rubber Beading of Starter (Gasket) | 2 | Nos | |
4005 | 69.36 | Replacement of NO/NC Auxiliary Contacts | 51 | Nos | |
4006 | 69.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4007 | 69.38 | Painting | 1 | Nos | |
4008 | 69.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4009 | 69.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4010 | 69.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4011 | 69.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4012 | 69.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4013 | 69.44 | Replacement of TPU (Thermal Power Unit) | 4 | Nos | |
4014 | 69.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 12 | Nos | |
4015 | 69.46 | Replacement of MCCB | 1 | Nos | |
4016 | 69.47 | Replacement of Power Diode | 94 | Nos | |
4017 | 69.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 3 | Nos | |
4018 | 69.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4019 | 69.5 | Replacement of Overload Relay | 4 | Nos | |
4020 | 69.51 | Replacement of Coils | 9 | Nos | |
4021 | 69.52 | Replacement of Voltage Relays | 9 | Nos | |
4022 | 69.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4023 | 69.54 | Renewal of 3 Core Cable | 1 | Nos | |
4024 | 69.55 | Replacement of Control Transformers | 1 | Nos | |
4025 | 69.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4026 | 69.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4027 | 69.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4028 | 69.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4029 | 69.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4030 | 69.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4031 | 69.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4032 | 69.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4033 | 69.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 9 | Nos | |
4034 | 69.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 4 | Nos | |
4035 | 70 | 150.1-200A | |||
4036 | 70.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
4037 | 70.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4038 | 70.03 | Calibration of O/L Relay | 1 | Nos | |
4039 | 70.04 | Repair of Coils | 1 | Nos | |
4040 | 70.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
4041 | 70.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
4042 | 70.07 | Replacement of Push Button switches | 1 | Nos | |
4043 | 70.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 10 | Nos | |
4044 | 70.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4045 | 70.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4046 | 70.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4047 | 70.12 | Repair of Control Transformers | 1 | Nos | |
4048 | 70.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4049 | 70.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4050 | 70.15 | Replacement of Control Fuses | 6 | Nos | |
4051 | 70.16 | Replacement of time delay relay | 3 | Nos | |
4052 | 70.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4053 | 70.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4054 | 70.19 | Replacement of Rotary Switches | 1 | Nos | |
4055 | 70.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4056 | 70.21 | Replacement of Bakelite Moulding Rate/MM | 2 | Nos | |
4057 | 70.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 21 | Nos | |
4058 | 70.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4059 | 70.24 | Replacement of Lock Pins | 1 | Nos | |
4060 | 70.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4061 | 70.26 | Replacement of Ebonite Board | 1 | Nos | |
4062 | 70.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4063 | 70.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4064 | 70.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
4065 | 70.3 | Replacement of Change Over Handle | 1 | Nos | |
4066 | 70.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4067 | 70.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4068 | 70.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4069 | 70.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4070 | 70.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4071 | 70.36 | Replacement of NO/NC Auxiliary Contacts | 6 | Nos | |
4072 | 70.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4073 | 70.38 | Painting | 1 | Nos | |
4074 | 70.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4075 | 70.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4076 | 70.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4077 | 70.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4078 | 70.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4079 | 70.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4080 | 70.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 2 | Nos | |
4081 | 70.46 | Replacement of MCCB | 1 | Nos | |
4082 | 70.47 | Replacement of Power Diode | 4 | Nos | |
4083 | 70.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4084 | 70.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4085 | 70.5 | Replacement of Overload Relay | 1 | Nos | |
4086 | 70.51 | Replacement of Coils | 1 | Nos | |
4087 | 70.52 | Replacement of Voltage Relays | 3 | Nos | |
4088 | 70.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4089 | 70.54 | Renewal of 3 Core Cable | 1 | Nos | |
4090 | 70.55 | Replacement of Control Transformers | 1 | Nos | |
4091 | 70.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4092 | 70.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4093 | 70.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4094 | 70.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4095 | 70.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4096 | 70.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4097 | 70.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4098 | 70.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4099 | 70.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 2 | Nos | |
4100 | 70.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
4101 | 71 | 200.1-300A | |||
4102 | 71.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
4103 | 71.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4104 | 71.03 | Calibration of O/L Relay | 1 | Nos | |
4105 | 71.04 | Repair of Coils | 1 | Nos | |
4106 | 71.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
4107 | 71.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
4108 | 71.07 | Replacement of Push Button switches | 1 | Nos | |
4109 | 71.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 17 | Nos | |
4110 | 71.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4111 | 71.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4112 | 71.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4113 | 71.12 | Repair of Control Transformers | 1 | Nos | |
4114 | 71.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4115 | 71.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4116 | 71.15 | Replacement of Control Fuses | 7 | Nos | |
4117 | 71.16 | Replacement of time delay relay | 3 | Nos | |
4118 | 71.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4119 | 71.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4120 | 71.19 | Replacement of Rotary Switches | 1 | Nos | |
4121 | 71.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4122 | 71.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
4123 | 71.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 17 | Nos | |
4124 | 71.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4125 | 71.24 | Replacement of Lock Pins | 1 | Nos | |
4126 | 71.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4127 | 71.26 | Replacement of Ebonite Board | 1 | Nos | |
4128 | 71.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4129 | 71.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4130 | 71.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
4131 | 71.3 | Replacement of Change Over Handle | 1 | Nos | |
4132 | 71.31 | Repair of Single Phase Protection Unit | 2 | Nos | |
4133 | 71.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4134 | 71.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4135 | 71.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4136 | 71.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4137 | 71.36 | Replacement of NO/NC Auxiliary Contacts | 11 | Nos | |
4138 | 71.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4139 | 71.38 | Painting | 1 | Nos | |
4140 | 71.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4141 | 71.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4142 | 71.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4143 | 71.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4144 | 71.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4145 | 71.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4146 | 71.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4147 | 71.46 | Replacement of MCCB | 1 | Nos | |
4148 | 71.47 | Replacement of Power Diode | 4 | Nos | |
4149 | 71.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4150 | 71.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4151 | 71.5 | Replacement of Overload Relay | 1 | Nos | |
4152 | 71.51 | Replacement of Coils | 1 | Nos | |
4153 | 71.52 | Replacement of Voltage Relays | 5 | Nos | |
4154 | 71.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4155 | 71.54 | Renewal of 3 Core Cable | 1 | Nos | |
4156 | 71.55 | Replacement of Control Transformers | 1 | Nos | |
4157 | 71.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4158 | 71.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4159 | 71.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4160 | 71.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4161 | 71.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4162 | 71.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4163 | 71.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4164 | 71.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4165 | 71.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
4166 | 71.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
4167 | 72 | 300.1-500A | |||
4168 | 72.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
4169 | 72.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4170 | 72.03 | Calibration of O/L Relay | 1 | Nos | |
4171 | 72.04 | Repair of Coils | 1 | Nos | |
4172 | 72.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
4173 | 72.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
4174 | 72.07 | Replacement of Push Button switches | 1 | Nos | |
4175 | 72.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
4176 | 72.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4177 | 72.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4178 | 72.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4179 | 72.12 | Repair of Control Transformers | 1 | Nos | |
4180 | 72.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4181 | 72.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4182 | 72.15 | Replacement of Control Fuses | 1 | Nos | |
4183 | 72.16 | Replacement of time delay relay | 1 | Nos | |
4184 | 72.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4185 | 72.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4186 | 72.19 | Replacement of Rotary Switches | 1 | Nos | |
4187 | 72.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4188 | 72.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
4189 | 72.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 40 | Nos | |
4190 | 72.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4191 | 72.24 | Replacement of Lock Pins | 1 | Nos | |
4192 | 72.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4193 | 72.26 | Replacement of Ebonite Board | 1 | Nos | |
4194 | 72.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4195 | 72.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4196 | 72.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
4197 | 72.3 | Replacement of Change Over Handle | 1 | Nos | |
4198 | 72.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4199 | 72.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4200 | 72.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4201 | 72.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4202 | 72.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4203 | 72.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
4204 | 72.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4205 | 72.38 | Painting | 1 | Nos | |
4206 | 72.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4207 | 72.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4208 | 72.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4209 | 72.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4210 | 72.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4211 | 72.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4212 | 72.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4213 | 72.46 | Replacement of MCCB | 1 | Nos | |
4214 | 72.47 | Replacement of Power Diode | 1 | Nos | |
4215 | 72.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4216 | 72.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4217 | 72.5 | Replacement of Overload Relay | 1 | Nos | |
4218 | 72.51 | Replacement of Coils | 1 | Nos | |
4219 | 72.52 | Replacement of Voltage Relays | 1 | Nos | |
4220 | 72.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4221 | 72.54 | Renewal of 3 Core Cable | 1 | Nos | |
4222 | 72.55 | Replacement of Control Transformers | 1 | Nos | |
4223 | 72.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4224 | 72.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4225 | 72.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4226 | 72.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4227 | 72.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4228 | 72.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4229 | 72.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4230 | 72.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4231 | 72.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
4232 | 72.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
4233 | 73 | 500.1-600A | |||
4234 | 73.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
4235 | 73.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4236 | 73.03 | Calibration of O/L Relay | 1 | Nos | |
4237 | 73.04 | Repair of Coils | 1 | Nos | |
4238 | 73.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
4239 | 73.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
4240 | 73.07 | Replacement of Push Button switches | 1 | Nos | |
4241 | 73.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
4242 | 73.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4243 | 73.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4244 | 73.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4245 | 73.12 | Repair of Control Transformers | 1 | Nos | |
4246 | 73.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4247 | 73.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4248 | 73.15 | Replacement of Control Fuses | 1 | Nos | |
4249 | 73.16 | Replacement of time delay relay | 1 | Nos | |
4250 | 73.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4251 | 73.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4252 | 73.19 | Replacement of Rotary Switches | 1 | Nos | |
4253 | 73.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4254 | 73.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
4255 | 73.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 3 | Nos | |
4256 | 73.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4257 | 73.24 | Replacement of Lock Pins | 1 | Nos | |
4258 | 73.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4259 | 73.26 | Replacement of Ebonite Board | 1 | Nos | |
4260 | 73.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4261 | 73.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4262 | 73.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
4263 | 73.3 | Replacement of Change Over Handle | 1 | Nos | |
4264 | 73.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4265 | 73.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4266 | 73.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4267 | 73.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4268 | 73.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4269 | 73.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
4270 | 73.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4271 | 73.38 | Painting | 1 | Nos | |
4272 | 73.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4273 | 73.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4274 | 73.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4275 | 73.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4276 | 73.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4277 | 73.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4278 | 73.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4279 | 73.46 | Replacement of MCCB | 1 | Nos | |
4280 | 73.47 | Replacement of Power Diode | 1 | Nos | |
4281 | 73.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4282 | 73.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4283 | 73.5 | Replacement of Overload Relay | 1 | Nos | |
4284 | 73.51 | Replacement of Coils | 1 | Nos | |
4285 | 73.52 | Replacement of Voltage Relays | 1 | Nos | |
4286 | 73.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4287 | 73.54 | Renewal of 3 Core Cable | 1 | Nos | |
4288 | 73.55 | Replacement of Control Transformers | 1 | Nos | |
4289 | 73.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4290 | 73.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4291 | 73.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4292 | 73.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4293 | 73.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4294 | 73.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4295 | 73.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4296 | 73.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4297 | 73.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
4298 | 73.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
4299 | 74 | SPARES | |||
4300 | 75 | 5A | |||
4301 | 75.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
4302 | 75.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4303 | 75.03 | Calibration of O/L Relay | 1 | Nos | |
4304 | 75.04 | Repair of Coils | 1 | Nos | |
4305 | 75.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
4306 | 75.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
4307 | 75.07 | Replacement of Push Button switches | 1 | Nos | |
4308 | 75.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
4309 | 75.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4310 | 75.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4311 | 75.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4312 | 75.12 | Repair of Control Transformers | 1 | Nos | |
4313 | 75.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4314 | 75.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4315 | 75.15 | Replacement of Control Fuses | 1 | Nos | |
4316 | 75.16 | Replacement of time delay relay | 1 | Nos | |
4317 | 75.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4318 | 75.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4319 | 75.19 | Replacement of Rotary Switches | 1 | Nos | |
4320 | 75.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4321 | 75.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
4322 | 75.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
4323 | 75.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4324 | 75.24 | Replacement of Lock Pins | 1 | Nos | |
4325 | 75.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4326 | 75.26 | Replacement of Ebonite Board | 1 | Nos | |
4327 | 75.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4328 | 75.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4329 | 75.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
4330 | 75.3 | Replacement of Change Over Handle | 1 | Nos | |
4331 | 75.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4332 | 75.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4333 | 75.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4334 | 75.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4335 | 75.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4336 | 75.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
4337 | 75.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4338 | 75.38 | Painting | 1 | Nos | |
4339 | 75.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4340 | 75.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4341 | 75.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4342 | 75.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4343 | 75.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4344 | 75.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4345 | 75.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4346 | 75.46 | Replacement of MCCB | 1 | Nos | |
4347 | 75.47 | Replacement of Power Diode | 1 | Nos | |
4348 | 75.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4349 | 75.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4350 | 75.5 | Replacement of Overload Relay | 1 | Nos | |
4351 | 75.51 | Replacement of Coils | 1 | Nos | |
4352 | 75.52 | Replacement of Voltage Relays | 1 | Nos | |
4353 | 75.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4354 | 75.54 | Renewal of 3 Core Cable | 1 | Nos | |
4355 | 75.55 | Replacement of Control Transformers | 1 | Nos | |
4356 | 75.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4357 | 75.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4358 | 75.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4359 | 75.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4360 | 75.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4361 | 75.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4362 | 75.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4363 | 75.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4364 | 75.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
4365 | 75.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
4366 | 76 | 5.1-10A | |||
4367 | 76.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
4368 | 76.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4369 | 76.03 | Calibration of O/L Relay | 1 | Nos | |
4370 | 76.04 | Repair of Coils | 1 | Nos | |
4371 | 76.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
4372 | 76.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
4373 | 76.07 | Replacement of Push Button switches | 1 | Nos | |
4374 | 76.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 7 | Nos | |
4375 | 76.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4376 | 76.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4377 | 76.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4378 | 76.12 | Repair of Control Transformers | 1 | Nos | |
4379 | 76.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4380 | 76.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4381 | 76.15 | Replacement of Control Fuses | 13 | Nos | |
4382 | 76.16 | Replacement of time delay relay | 1 | Nos | |
4383 | 76.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4384 | 76.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4385 | 76.19 | Replacement of Rotary Switches | 1 | Nos | |
4386 | 76.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4387 | 76.21 | Replacement of Bakelite Moulding Rate/MM | 10 | Nos | |
4388 | 76.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
4389 | 76.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4390 | 76.24 | Replacement of Lock Pins | 1 | Nos | |
4391 | 76.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4392 | 76.26 | Replacement of Ebonite Board | 1 | Nos | |
4393 | 76.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4394 | 76.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4395 | 76.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
4396 | 76.3 | Replacement of Change Over Handle | 1 | Nos | |
4397 | 76.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4398 | 76.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4399 | 76.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4400 | 76.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4401 | 76.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4402 | 76.36 | Replacement of NO/NC Auxiliary Contacts | 2 | Nos | |
4403 | 76.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4404 | 76.38 | Painting | 1 | Nos | |
4405 | 76.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4406 | 76.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4407 | 76.41 | Repair of Electronic Protection Unit | 2 | Nos | |
4408 | 76.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
4409 | 76.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4410 | 76.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4411 | 76.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4412 | 76.46 | Replacement of MCCB | 1 | Nos | |
4413 | 76.47 | Replacement of Power Diode | 1 | Nos | |
4414 | 76.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4415 | 76.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4416 | 76.5 | Replacement of Overload Relay | 6 | Nos | |
4417 | 76.51 | Replacement of Coils | 1 | Nos | |
4418 | 76.52 | Replacement of Voltage Relays | 1 | Nos | |
4419 | 76.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
4420 | 76.54 | Renewal of 3 Core Cable | 1 | Nos | |
4421 | 76.55 | Replacement of Control Transformers | 1 | Nos | |
4422 | 76.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4423 | 76.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4424 | 76.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4425 | 76.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4426 | 76.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4427 | 76.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4428 | 76.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4429 | 76.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4430 | 76.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
4431 | 76.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
4432 | 77 | 10.1-15A | |||
4433 | 77.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 58 | Nos | |
4434 | 77.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4435 | 77.03 | Calibration of O/L Relay | 1 | Nos | |
4436 | 77.04 | Repair of Coils | 1 | Nos | |
4437 | 77.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 7 | Nos | |
4438 | 77.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 47 | Nos | |
4439 | 77.07 | Replacement of Push Button switches | 1 | Nos | |
4440 | 77.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 38 | Nos | |
4441 | 77.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 5 | Nos | |
4442 | 77.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4443 | 77.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4444 | 77.12 | Repair of Control Transformers | 2 | Nos | |
4445 | 77.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
4446 | 77.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4447 | 77.15 | Replacement of Control Fuses | 99 | Nos | |
4448 | 77.16 | Replacement of time delay relay | 6 | Nos | |
4449 | 77.17 | Replacement of Indication Lamps and Holders | 6 | Nos | |
4450 | 77.18 | Replacement of ON/OFF Push Units | 2 | Nos | |
4451 | 77.19 | Replacement of Rotary Switches | 1 | Nos | |
4452 | 77.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4453 | 77.21 | Replacement of Bakelite Moulding Rate/MM | 7 | Nos | |
4454 | 77.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 1 | Nos | |
4455 | 77.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4456 | 77.24 | Replacement of Lock Pins | 1 | Nos | |
4457 | 77.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4458 | 77.26 | Replacement of Ebonite Board | 1 | Nos | |
4459 | 77.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4460 | 77.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4461 | 77.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
4462 | 77.3 | Replacement of Change Over Handle | 1 | Nos | |
4463 | 77.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
4464 | 77.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4465 | 77.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4466 | 77.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4467 | 77.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4468 | 77.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
4469 | 77.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4470 | 77.38 | Painting | 1 | Nos | |
4471 | 77.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4472 | 77.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4473 | 77.41 | Repair of Electronic Protection Unit | 5 | Nos | |
4474 | 77.42 | Replacement of Electronic Protection Unit | 26 | Nos | |
4475 | 77.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4476 | 77.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4477 | 77.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4478 | 77.46 | Replacement of MCCB | 1 | Nos | |
4479 | 77.47 | Replacement of Power Diode | 1 | Nos | |
4480 | 77.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4481 | 77.49 | Replacement of Socket (Brass & Ebonite) | 2 | Nos | |
4482 | 77.5 | Replacement of Overload Relay | 53 | Nos | |
4483 | 77.51 | Replacement of Coils | 3 | Nos | |
4484 | 77.52 | Replacement of Voltage Relays | 2 | Nos | |
4485 | 77.53 | Replacement of ON/OFF Stage Over Switch | 21 | Nos | |
4486 | 77.54 | Renewal of 3 Core Cable | 1 | Nos | |
4487 | 77.55 | Replacement of Control Transformers | 1 | Nos | |
4488 | 77.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4489 | 77.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4490 | 77.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4491 | 77.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4492 | 77.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4493 | 77.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4494 | 77.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4495 | 77.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4496 | 77.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
4497 | 77.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
4498 | 78 | 15.1-20A | |||
4499 | 78.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 14 | Nos | |
4500 | 78.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4501 | 78.03 | Calibration of O/L Relay | 1 | Nos | |
4502 | 78.04 | Repair of Coils | 1 | Nos | |
4503 | 78.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
4504 | 78.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 11 | Nos | |
4505 | 78.07 | Replacement of Push Button switches | 1 | Nos | |
4506 | 78.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 3 | Nos | |
4507 | 78.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4508 | 78.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4509 | 78.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4510 | 78.12 | Repair of Control Transformers | 1 | Nos | |
4511 | 78.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 2 | Nos | |
4512 | 78.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4513 | 78.15 | Replacement of Control Fuses | 25 | Nos | |
4514 | 78.16 | Replacement of time delay relay | 4 | Nos | |
4515 | 78.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4516 | 78.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4517 | 78.19 | Replacement of Rotary Switches | 1 | Nos | |
4518 | 78.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4519 | 78.21 | Replacement of Bakelite Moulding Rate/MM | 8 | Nos | |
4520 | 78.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 6 | Nos | |
4521 | 78.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4522 | 78.24 | Replacement of Lock Pins | 1 | Nos | |
4523 | 78.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4524 | 78.26 | Replacement of Ebonite Board | 1 | Nos | |
4525 | 78.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4526 | 78.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4527 | 78.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
4528 | 78.3 | Replacement of Change Over Handle | 1 | Nos | |
4529 | 78.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4530 | 78.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4531 | 78.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4532 | 78.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4533 | 78.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4534 | 78.36 | Replacement of NO/NC Auxiliary Contacts | 3 | Nos | |
4535 | 78.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4536 | 78.38 | Painting | 2 | Nos | |
4537 | 78.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4538 | 78.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4539 | 78.41 | Repair of Electronic Protection Unit | 2 | Nos | |
4540 | 78.42 | Replacement of Electronic Protection Unit | 5 | Nos | |
4541 | 78.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4542 | 78.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4543 | 78.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4544 | 78.46 | Replacement of MCCB | 1 | Nos | |
4545 | 78.47 | Replacement of Power Diode | 1 | Nos | |
4546 | 78.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4547 | 78.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4548 | 78.5 | Replacement of Overload Relay | 12 | Nos | |
4549 | 78.51 | Replacement of Coils | 1 | Nos | |
4550 | 78.52 | Replacement of Voltage Relays | 1 | Nos | |
4551 | 78.53 | Replacement of ON/OFF Stage Over Switch | 8 | Nos | |
4552 | 78.54 | Renewal of 3 Core Cable | 1 | Nos | |
4553 | 78.55 | Replacement of Control Transformers | 1 | Nos | |
4554 | 78.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4555 | 78.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4556 | 78.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4557 | 78.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4558 | 78.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4559 | 78.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4560 | 78.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4561 | 78.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4562 | 78.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
4563 | 78.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
4564 | 79 | 20.1-30A | |||
4565 | 79.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 2 | Nos | |
4566 | 79.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4567 | 79.03 | Calibration of O/L Relay | 1 | Nos | |
4568 | 79.04 | Repair of Coils | 1 | Nos | |
4569 | 79.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
4570 | 79.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
4571 | 79.07 | Replacement of Push Button switches | 1 | Nos | |
4572 | 79.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 5 | Nos | |
4573 | 79.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4574 | 79.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4575 | 79.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4576 | 79.12 | Repair of Control Transformers | 1 | Nos | |
4577 | 79.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4578 | 79.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4579 | 79.15 | Replacement of Control Fuses | 2 | Nos | |
4580 | 79.16 | Replacement of time delay relay | 1 | Nos | |
4581 | 79.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4582 | 79.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4583 | 79.19 | Replacement of Rotary Switches | 1 | Nos | |
4584 | 79.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4585 | 79.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
4586 | 79.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 2 | Nos | |
4587 | 79.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4588 | 79.24 | Replacement of Lock Pins | 1 | Nos | |
4589 | 79.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4590 | 79.26 | Replacement of Ebonite Board | 1 | Nos | |
4591 | 79.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4592 | 79.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4593 | 79.29 | Replacement of Wire Wound Resistors | 2 | Nos | |
4594 | 79.3 | Replacement of Change Over Handle | 1 | Nos | |
4595 | 79.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4596 | 79.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4597 | 79.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4598 | 79.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4599 | 79.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4600 | 79.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
4601 | 79.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4602 | 79.38 | Painting | 1 | Nos | |
4603 | 79.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4604 | 79.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4605 | 79.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4606 | 79.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4607 | 79.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4608 | 79.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4609 | 79.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4610 | 79.46 | Replacement of MCCB | 1 | Nos | |
4611 | 79.47 | Replacement of Power Diode | 1 | Nos | |
4612 | 79.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4613 | 79.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4614 | 79.5 | Replacement of Overload Relay | 2 | Nos | |
4615 | 79.51 | Replacement of Coils | 1 | Nos | |
4616 | 79.52 | Replacement of Voltage Relays | 1 | Nos | |
4617 | 79.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4618 | 79.54 | Renewal of 3 Core Cable | 1 | Nos | |
4619 | 79.55 | Replacement of Control Transformers | 1 | Nos | |
4620 | 79.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4621 | 79.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4622 | 79.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4623 | 79.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4624 | 79.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4625 | 79.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4626 | 79.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4627 | 79.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4628 | 79.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
4629 | 79.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
4630 | 80 | 30.1-50A | |||
4631 | 80.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 8 | Nos | |
4632 | 80.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4633 | 80.03 | Calibration of O/L Relay | 1 | Nos | |
4634 | 80.04 | Repair of Coils | 1 | Nos | |
4635 | 80.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 3 | Nos | |
4636 | 80.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
4637 | 80.07 | Replacement of Push Button switches | 1 | Nos | |
4638 | 80.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 15 | Nos | |
4639 | 80.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4640 | 80.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4641 | 80.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4642 | 80.12 | Repair of Control Transformers | 1 | Nos | |
4643 | 80.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4644 | 80.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4645 | 80.15 | Replacement of Control Fuses | 14 | Nos | |
4646 | 80.16 | Replacement of time delay relay | 3 | Nos | |
4647 | 80.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4648 | 80.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4649 | 80.19 | Replacement of Rotary Switches | 1 | Nos | |
4650 | 80.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4651 | 80.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
4652 | 80.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 24 | Nos | |
4653 | 80.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4654 | 80.24 | Replacement of Lock Pins | 1 | Nos | |
4655 | 80.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4656 | 80.26 | Replacement of Ebonite Board | 1 | Nos | |
4657 | 80.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4658 | 80.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4659 | 80.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
4660 | 80.3 | Replacement of Change Over Handle | 1 | Nos | |
4661 | 80.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4662 | 80.32 | Repair of 3 Ph 4 Way Rotary Switch | 4 | Nos | |
4663 | 80.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4664 | 80.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4665 | 80.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4666 | 80.36 | Replacement of NO/NC Auxiliary Contacts | 7 | Nos | |
4667 | 80.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4668 | 80.38 | Painting | 1 | Nos | |
4669 | 80.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4670 | 80.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4671 | 80.41 | Repair of Electronic Protection Unit | 2 | Nos | |
4672 | 80.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4673 | 80.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4674 | 80.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4675 | 80.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4676 | 80.46 | Replacement of MCCB | 1 | Nos | |
4677 | 80.47 | Replacement of Power Diode | 20 | Nos | |
4678 | 80.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4679 | 80.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4680 | 80.5 | Replacement of Overload Relay | 2 | Nos | |
4681 | 80.51 | Replacement of Coils | 3 | Nos | |
4682 | 80.52 | Replacement of Voltage Relays | 6 | Nos | |
4683 | 80.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
4684 | 80.54 | Renewal of 3 Core Cable | 1 | Nos | |
4685 | 80.55 | Replacement of Control Transformers | 1 | Nos | |
4686 | 80.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4687 | 80.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4688 | 80.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4689 | 80.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4690 | 80.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4691 | 80.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4692 | 80.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4693 | 80.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4694 | 80.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 6 | Nos | |
4695 | 80.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
4696 | 81 | 50.1-75A | |||
4697 | 81.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 7 | Nos | |
4698 | 81.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4699 | 81.03 | Calibration of O/L Relay | 1 | Nos | |
4700 | 81.04 | Repair of Coils | 1 | Nos | |
4701 | 81.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
4702 | 81.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 4 | Nos | |
4703 | 81.07 | Replacement of Push Button switches | 1 | Nos | |
4704 | 81.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 40 | Nos | |
4705 | 81.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4706 | 81.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4707 | 81.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4708 | 81.12 | Repair of Control Transformers | 1 | Nos | |
4709 | 81.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4710 | 81.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4711 | 81.15 | Replacement of Control Fuses | 20 | Nos | |
4712 | 81.16 | Replacement of time delay relay | 1 | Nos | |
4713 | 81.17 | Replacement of Indication Lamps and Holders | 3 | Nos | |
4714 | 81.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4715 | 81.19 | Replacement of Rotary Switches | 1 | Nos | |
4716 | 81.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4717 | 81.21 | Replacement of Bakelite Moulding Rate/MM | 9 | Nos | |
4718 | 81.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 18 | Nos | |
4719 | 81.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4720 | 81.24 | Replacement of Lock Pins | 1 | Nos | |
4721 | 81.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4722 | 81.26 | Replacement of Ebonite Board | 1 | Nos | |
4723 | 81.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4724 | 81.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4725 | 81.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
4726 | 81.3 | Replacement of Change Over Handle | 1 | Nos | |
4727 | 81.31 | Repair of Single Phase Protection Unit | 4 | Nos | |
4728 | 81.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4729 | 81.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4730 | 81.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4731 | 81.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4732 | 81.36 | Replacement of NO/NC Auxiliary Contacts | 13 | Nos | |
4733 | 81.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4734 | 81.38 | Painting | 1 | Nos | |
4735 | 81.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4736 | 81.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4737 | 81.41 | Repair of Electronic Protection Unit | 3 | Nos | |
4738 | 81.42 | Replacement of Electronic Protection Unit | 3 | Nos | |
4739 | 81.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4740 | 81.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4741 | 81.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4742 | 81.46 | Replacement of MCCB | 1 | Nos | |
4743 | 81.47 | Replacement of Power Diode | 5 | Nos | |
4744 | 81.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4745 | 81.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4746 | 81.5 | Replacement of Overload Relay | 1 | Nos | |
4747 | 81.51 | Replacement of Coils | 1 | Nos | |
4748 | 81.52 | Replacement of Voltage Relays | 3 | Nos | |
4749 | 81.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4750 | 81.54 | Renewal of 3 Core Cable | 1 | Nos | |
4751 | 81.55 | Replacement of Control Transformers | 1 | Nos | |
4752 | 81.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4753 | 81.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4754 | 81.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4755 | 81.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4756 | 81.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4757 | 81.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4758 | 81.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4759 | 81.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4760 | 81.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
4761 | 81.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
4762 | 82 | 75.1-100A | |||
4763 | 82.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 9 | Nos | |
4764 | 82.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4765 | 82.03 | Calibration of O/L Relay | 1 | Nos | |
4766 | 82.04 | Repair of Coils | 1 | Nos | |
4767 | 82.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 4 | Nos | |
4768 | 82.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 5 | Nos | |
4769 | 82.07 | Replacement of Push Button switches | 1 | Nos | |
4770 | 82.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 25 | Nos | |
4771 | 82.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4772 | 82.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4773 | 82.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4774 | 82.12 | Repair of Control Transformers | 1 | Nos | |
4775 | 82.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4776 | 82.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4777 | 82.15 | Replacement of Control Fuses | 17 | Nos | |
4778 | 82.16 | Replacement of time delay relay | 4 | Nos | |
4779 | 82.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4780 | 82.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4781 | 82.19 | Replacement of Rotary Switches | 1 | Nos | |
4782 | 82.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4783 | 82.21 | Replacement of Bakelite Moulding Rate/MM | 6 | Nos | |
4784 | 82.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 27 | Nos | |
4785 | 82.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4786 | 82.24 | Replacement of Lock Pins | 1 | Nos | |
4787 | 82.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4788 | 82.26 | Replacement of Ebonite Board | 1 | Nos | |
4789 | 82.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 9 | Nos | |
4790 | 82.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4791 | 82.29 | Replacement of Wire Wound Resistors | 9 | Nos | |
4792 | 82.3 | Replacement of Change Over Handle | 1 | Nos | |
4793 | 82.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4794 | 82.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4795 | 82.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4796 | 82.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4797 | 82.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4798 | 82.36 | Replacement of NO/NC Auxiliary Contacts | 10 | Nos | |
4799 | 82.37 | Repair of Amp/Volt Meter | 2 | Nos | |
4800 | 82.38 | Painting | 1 | Nos | |
4801 | 82.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4802 | 82.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4803 | 82.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4804 | 82.42 | Replacement of Electronic Protection Unit | 2 | Nos | |
4805 | 82.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4806 | 82.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4807 | 82.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
4808 | 82.46 | Replacement of MCCB | 1 | Nos | |
4809 | 82.47 | Replacement of Power Diode | 18 | Nos | |
4810 | 82.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4811 | 82.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4812 | 82.5 | Replacement of Overload Relay | 3 | Nos | |
4813 | 82.51 | Replacement of Coils | 3 | Nos | |
4814 | 82.52 | Replacement of Voltage Relays | 6 | Nos | |
4815 | 82.53 | Replacement of ON/OFF Stage Over Switch | 2 | Nos | |
4816 | 82.54 | Renewal of 3 Core Cable | 1 | Nos | |
4817 | 82.55 | Replacement of Control Transformers | 1 | Nos | |
4818 | 82.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4819 | 82.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4820 | 82.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4821 | 82.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4822 | 82.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4823 | 82.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4824 | 82.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4825 | 82.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4826 | 82.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
4827 | 82.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 3 | Nos | |
4828 | 83 | 100.1-150A | |||
4829 | 83.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 21 | Nos | |
4830 | 83.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4831 | 83.03 | Calibration of O/L Relay | 1 | Nos | |
4832 | 83.04 | Repair of Coils | 1 | Nos | |
4833 | 83.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 5 | Nos | |
4834 | 83.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 6 | Nos | |
4835 | 83.07 | Replacement of Push Button switches | 1 | Nos | |
4836 | 83.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 79 | Nos | |
4837 | 83.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4838 | 83.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 2 | Nos | |
4839 | 83.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4840 | 83.12 | Repair of Control Transformers | 1 | Nos | |
4841 | 83.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4842 | 83.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 4 | Nos | |
4843 | 83.15 | Replacement of Control Fuses | 43 | Nos | |
4844 | 83.16 | Replacement of time delay relay | 16 | Nos | |
4845 | 83.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4846 | 83.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4847 | 83.19 | Replacement of Rotary Switches | 1 | Nos | |
4848 | 83.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4849 | 83.21 | Replacement of Bakelite Moulding Rate/MM | 15 | Nos | |
4850 | 83.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 61 | Nos | |
4851 | 83.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 4 | Nos | |
4852 | 83.24 | Replacement of Lock Pins | 1 | Nos | |
4853 | 83.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4854 | 83.26 | Replacement of Ebonite Board | 1 | Nos | |
4855 | 83.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 10 | Nos | |
4856 | 83.28 | Replacement of Bakelite Switches and Knobs | 2 | Nos | |
4857 | 83.29 | Replacement of Wire Wound Resistors | 67 | Nos | |
4858 | 83.3 | Replacement of Change Over Handle | 1 | Nos | |
4859 | 83.31 | Repair of Single Phase Protection Unit | 3 | Nos | |
4860 | 83.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4861 | 83.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4862 | 83.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4863 | 83.35 | Replacement of Rubber Beading of Starter (Gasket) | 2 | Nos | |
4864 | 83.36 | Replacement of NO/NC Auxiliary Contacts | 51 | Nos | |
4865 | 83.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4866 | 83.38 | Painting | 1 | Nos | |
4867 | 83.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4868 | 83.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4869 | 83.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4870 | 83.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4871 | 83.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4872 | 83.44 | Replacement of TPU (Thermal Power Unit) | 4 | Nos | |
4873 | 83.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 12 | Nos | |
4874 | 83.46 | Replacement of MCCB | 1 | Nos | |
4875 | 83.47 | Replacement of Power Diode | 94 | Nos | |
4876 | 83.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 3 | Nos | |
4877 | 83.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4878 | 83.5 | Replacement of Overload Relay | 4 | Nos | |
4879 | 83.51 | Replacement of Coils | 9 | Nos | |
4880 | 83.52 | Replacement of Voltage Relays | 9 | Nos | |
4881 | 83.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4882 | 83.54 | Renewal of 3 Core Cable | 1 | Nos | |
4883 | 83.55 | Replacement of Control Transformers | 1 | Nos | |
4884 | 83.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4885 | 83.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4886 | 83.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4887 | 83.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4888 | 83.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4889 | 83.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4890 | 83.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4891 | 83.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4892 | 83.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 9 | Nos | |
4893 | 83.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 4 | Nos | |
4894 | 84 | 150.1-200A | |||
4895 | 84.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
4896 | 84.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4897 | 84.03 | Calibration of O/L Relay | 1 | Nos | |
4898 | 84.04 | Repair of Coils | 1 | Nos | |
4899 | 84.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
4900 | 84.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
4901 | 84.07 | Replacement of Push Button switches | 1 | Nos | |
4902 | 84.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 10 | Nos | |
4903 | 84.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4904 | 84.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4905 | 84.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4906 | 84.12 | Repair of Control Transformers | 1 | Nos | |
4907 | 84.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4908 | 84.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4909 | 84.15 | Replacement of Control Fuses | 6 | Nos | |
4910 | 84.16 | Replacement of time delay relay | 3 | Nos | |
4911 | 84.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4912 | 84.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4913 | 84.19 | Replacement of Rotary Switches | 1 | Nos | |
4914 | 84.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4915 | 84.21 | Replacement of Bakelite Moulding Rate/MM | 2 | Nos | |
4916 | 84.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 21 | Nos | |
4917 | 84.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4918 | 84.24 | Replacement of Lock Pins | 1 | Nos | |
4919 | 84.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4920 | 84.26 | Replacement of Ebonite Board | 1 | Nos | |
4921 | 84.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4922 | 84.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4923 | 84.29 | Replacement of Wire Wound Resistors | 3 | Nos | |
4924 | 84.3 | Replacement of Change Over Handle | 1 | Nos | |
4925 | 84.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
4926 | 84.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4927 | 84.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4928 | 84.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4929 | 84.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4930 | 84.36 | Replacement of NO/NC Auxiliary Contacts | 6 | Nos | |
4931 | 84.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4932 | 84.38 | Painting | 1 | Nos | |
4933 | 84.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4934 | 84.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
4935 | 84.41 | Repair of Electronic Protection Unit | 1 | Nos | |
4936 | 84.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
4937 | 84.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
4938 | 84.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
4939 | 84.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 2 | Nos | |
4940 | 84.46 | Replacement of MCCB | 1 | Nos | |
4941 | 84.47 | Replacement of Power Diode | 4 | Nos | |
4942 | 84.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
4943 | 84.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
4944 | 84.5 | Replacement of Overload Relay | 1 | Nos | |
4945 | 84.51 | Replacement of Coils | 1 | Nos | |
4946 | 84.52 | Replacement of Voltage Relays | 3 | Nos | |
4947 | 84.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
4948 | 84.54 | Renewal of 3 Core Cable | 1 | Nos | |
4949 | 84.55 | Replacement of Control Transformers | 1 | Nos | |
4950 | 84.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
4951 | 84.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
4952 | 84.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
4953 | 84.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
4954 | 84.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4955 | 84.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4956 | 84.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4957 | 84.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
4958 | 84.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 2 | Nos | |
4959 | 84.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 2 | Nos | |
4960 | 85 | 200.1-300A | |||
4961 | 85.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 6 | Nos | |
4962 | 85.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
4963 | 85.03 | Calibration of O/L Relay | 1 | Nos | |
4964 | 85.04 | Repair of Coils | 1 | Nos | |
4965 | 85.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 2 | Nos | |
4966 | 85.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 2 | Nos | |
4967 | 85.07 | Replacement of Push Button switches | 1 | Nos | |
4968 | 85.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 17 | Nos | |
4969 | 85.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
4970 | 85.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
4971 | 85.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
4972 | 85.12 | Repair of Control Transformers | 1 | Nos | |
4973 | 85.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4974 | 85.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
4975 | 85.15 | Replacement of Control Fuses | 7 | Nos | |
4976 | 85.16 | Replacement of time delay relay | 3 | Nos | |
4977 | 85.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
4978 | 85.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
4979 | 85.19 | Replacement of Rotary Switches | 1 | Nos | |
4980 | 85.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
4981 | 85.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
4982 | 85.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 17 | Nos | |
4983 | 85.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
4984 | 85.24 | Replacement of Lock Pins | 1 | Nos | |
4985 | 85.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
4986 | 85.26 | Replacement of Ebonite Board | 1 | Nos | |
4987 | 85.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
4988 | 85.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
4989 | 85.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
4990 | 85.3 | Replacement of Change Over Handle | 1 | Nos | |
4991 | 85.31 | Repair of Single Phase Protection Unit | 2 | Nos | |
4992 | 85.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4993 | 85.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
4994 | 85.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
4995 | 85.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
4996 | 85.36 | Replacement of NO/NC Auxiliary Contacts | 11 | Nos | |
4997 | 85.37 | Repair of Amp/Volt Meter | 1 | Nos | |
4998 | 85.38 | Painting | 1 | Nos | |
4999 | 85.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
5000 | 85.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
5001 | 85.41 | Repair of Electronic Protection Unit | 1 | Nos | |
5002 | 85.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
5003 | 85.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
5004 | 85.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
5005 | 85.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
5006 | 85.46 | Replacement of MCCB | 1 | Nos | |
5007 | 85.47 | Replacement of Power Diode | 4 | Nos | |
5008 | 85.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
5009 | 85.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
5010 | 85.5 | Replacement of Overload Relay | 1 | Nos | |
5011 | 85.51 | Replacement of Coils | 1 | Nos | |
5012 | 85.52 | Replacement of Voltage Relays | 5 | Nos | |
5013 | 85.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
5014 | 85.54 | Renewal of 3 Core Cable | 1 | Nos | |
5015 | 85.55 | Replacement of Control Transformers | 1 | Nos | |
5016 | 85.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
5017 | 85.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
5018 | 85.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
5019 | 85.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
5020 | 85.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5021 | 85.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5022 | 85.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5023 | 85.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5024 | 85.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 4 | Nos | |
5025 | 85.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
5026 | 86 | 300.1-500A | |||
5027 | 86.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 4 | Nos | |
5028 | 86.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
5029 | 86.03 | Calibration of O/L Relay | 1 | Nos | |
5030 | 86.04 | Repair of Coils | 1 | Nos | |
5031 | 86.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
5032 | 86.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
5033 | 86.07 | Replacement of Push Button switches | 1 | Nos | |
5034 | 86.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
5035 | 86.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
5036 | 86.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
5037 | 86.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
5038 | 86.12 | Repair of Control Transformers | 1 | Nos | |
5039 | 86.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
5040 | 86.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
5041 | 86.15 | Replacement of Control Fuses | 1 | Nos | |
5042 | 86.16 | Replacement of time delay relay | 1 | Nos | |
5043 | 86.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
5044 | 86.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
5045 | 86.19 | Replacement of Rotary Switches | 1 | Nos | |
5046 | 86.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
5047 | 86.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
5048 | 86.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 40 | Nos | |
5049 | 86.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
5050 | 86.24 | Replacement of Lock Pins | 1 | Nos | |
5051 | 86.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
5052 | 86.26 | Replacement of Ebonite Board | 1 | Nos | |
5053 | 86.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
5054 | 86.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
5055 | 86.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
5056 | 86.3 | Replacement of Change Over Handle | 1 | Nos | |
5057 | 86.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
5058 | 86.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
5059 | 86.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
5060 | 86.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
5061 | 86.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
5062 | 86.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
5063 | 86.37 | Repair of Amp/Volt Meter | 1 | Nos | |
5064 | 86.38 | Painting | 1 | Nos | |
5065 | 86.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
5066 | 86.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
5067 | 86.41 | Repair of Electronic Protection Unit | 1 | Nos | |
5068 | 86.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
5069 | 86.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
5070 | 86.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
5071 | 86.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
5072 | 86.46 | Replacement of MCCB | 1 | Nos | |
5073 | 86.47 | Replacement of Power Diode | 1 | Nos | |
5074 | 86.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
5075 | 86.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
5076 | 86.5 | Replacement of Overload Relay | 1 | Nos | |
5077 | 86.51 | Replacement of Coils | 1 | Nos | |
5078 | 86.52 | Replacement of Voltage Relays | 1 | Nos | |
5079 | 86.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
5080 | 86.54 | Renewal of 3 Core Cable | 1 | Nos | |
5081 | 86.55 | Replacement of Control Transformers | 1 | Nos | |
5082 | 86.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
5083 | 86.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
5084 | 86.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
5085 | 86.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
5086 | 86.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5087 | 86.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5088 | 86.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5089 | 86.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5090 | 86.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
5091 | 86.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos | |
5092 | 87 | 500.1-600A | |||
5093 | 87.01 | Overhauling/Servicing - clean Parts/area using OKS 2201& install VPC 1105/111 emitter in enclosure | 1 | Nos | |
5094 | 87.02 | Repair of overload Relay- clean parts/area using OKS 2201 | 1 | Nos | |
5095 | 87.03 | Calibration of O/L Relay | 1 | Nos | |
5096 | 87.04 | Repair of Coils | 1 | Nos | |
5097 | 87.05 | Repair of contactors (Siemens Make) Clean parts/area using OKS 2201 | 1 | Nos | |
5098 | 87.06 | Replacement of contactors (Siemens Make) clean Parts/area using OKS 2201 | 1 | Nos | |
5099 | 87.07 | Replacement of Push Button switches | 1 | Nos | |
5100 | 87.08 | Renewal of wiring and cable lugs clean parts/area using OKS 2201 | 1 | Nos | |
5101 | 87.09 | Repair of MCBs, MCCBs, clean parts/area using OKS 2201 | 1 | Nos | |
5102 | 87.1 | Repair of PCBs/Stabilizers with components clean parts/area using OKS 2201 | 1 | Nos | |
5103 | 87.11 | Repair/Calibration of Voltage Relays clean parts/area using OKS 2201 | 1 | Nos | |
5104 | 87.12 | Repair of Control Transformers | 1 | Nos | |
5105 | 87.13 | Replacement of Single Phase Protection Unit clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
5106 | 87.14 | Replacement of Selenium Rectifiers clean parts/area using OKS 2201 & 2601 | 1 | Nos | |
5107 | 87.15 | Replacement of Control Fuses | 1 | Nos | |
5108 | 87.16 | Replacement of time delay relay | 1 | Nos | |
5109 | 87.17 | Replacement of Indication Lamps and Holders | 1 | Nos | |
5110 | 87.18 | Replacement of ON/OFF Push Units | 1 | Nos | |
5111 | 87.19 | Replacement of Rotary Switches | 1 | Nos | |
5112 | 87.2 | Replacement/Repair of Bus Bar clean parts/area using OKS 2201 | 1 | Nos | |
5113 | 87.21 | Replacement of Bakelite Moulding Rate/MM | 1 | Nos | |
5114 | 87.22 | Replacement of Contacts (Bridge, Fixed, Movable, V type, L type, W type) and coat with OKS 2201 | 3 | Nos | |
5115 | 87.23 | Replacement of S.S. Studs/Brass Nut and Bolts & Coat with OKS 2201 | 1 | Nos | |
5116 | 87.24 | Replacement of Lock Pins | 1 | Nos | |
5117 | 87.25 | Replacement of Copper Securing Clamp Clean parts/area using OKS 2201 | 1 | Nos | |
5118 | 87.26 | Replacement of Ebonite Board | 1 | Nos | |
5119 | 87.27 | Replacement of 12 Diode Bridge Rectifier with Base Plate clean parts/area using OKS 2201 | 1 | Nos | |
5120 | 87.28 | Replacement of Bakelite Switches and Knobs | 1 | Nos | |
5121 | 87.29 | Replacement of Wire Wound Resistors | 1 | Nos | |
5122 | 87.3 | Replacement of Change Over Handle | 1 | Nos | |
5123 | 87.31 | Repair of Single Phase Protection Unit | 1 | Nos | |
5124 | 87.32 | Repair of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
5125 | 87.33 | Replacement of 3 Ph 4 Way Rotary Switch | 1 | Nos | |
5126 | 87.34 | Replacement of Brass Plug/Socket | 1 | Nos | |
5127 | 87.35 | Replacement of Rubber Beading of Starter (Gasket) | 1 | Nos | |
5128 | 87.36 | Replacement of NO/NC Auxiliary Contacts | 1 | Nos | |
5129 | 87.37 | Repair of Amp/Volt Meter | 1 | Nos | |
5130 | 87.38 | Painting | 1 | Nos | |
5131 | 87.39 | Repair of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
5132 | 87.4 | Replacement of 3 Phase 2 Way Rotary Switch | 1 | Nos | |
5133 | 87.41 | Repair of Electronic Protection Unit | 1 | Nos | |
5134 | 87.42 | Replacement of Electronic Protection Unit | 1 | Nos | |
5135 | 87.43 | Repair of TPU (Thermal Power Unit) | 1 | Nos | |
5136 | 87.44 | Replacement of TPU (Thermal Power Unit) | 1 | Nos | |
5137 | 87.45 | Replacement of Components of Emergency Control Box (Roller Assembly, Contacts, Terminal Plates) | 1 | Nos | |
5138 | 87.46 | Replacement of MCCB | 1 | Nos | |
5139 | 87.47 | Replacement of Power Diode | 1 | Nos | |
5140 | 87.48 | Replacement of Interlocking Switch Components (Roller Assembly, Contacts, Terminal Plate) | 1 | Nos | |
5141 | 87.49 | Replacement of Socket (Brass & Ebonite) | 1 | Nos | |
5142 | 87.5 | Replacement of Overload Relay | 1 | Nos | |
5143 | 87.51 | Replacement of Coils | 1 | Nos | |
5144 | 87.52 | Replacement of Voltage Relays | 1 | Nos | |
5145 | 87.53 | Replacement of ON/OFF Stage Over Switch | 1 | Nos | |
5146 | 87.54 | Renewal of 3 Core Cable | 1 | Nos | |
5147 | 87.55 | Replacement of Control Transformers | 1 | Nos | |
5148 | 87.56 | Fitment of Terminal Connector Blocks | 1 | Nos | |
5149 | 87.57 | Calibration of Starters and providing a Calibration Certificate | 1 | Nos | |
5150 | 87.58 | Calibration of ACOS AND Providing a Calibration Certificate | 1 | Nos | |
5151 | 87.59 | Overhaul of Soft Starters excluding Memory Devices, Logic Controller Circuits, PCBs & Solid State Devices | 1 | Nos | |
5152 | 87.6 | Overhaul of Control Panels including Body Repair, Painting, Replacement of Securing Screws, Nut & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5153 | 87.61 | Overhaul of Starters including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5154 | 87.62 | Overhaul of ACOS including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5155 | 87.63 | Overhaul of HCOS, including Body Repair, Painting, Replacement of Securing Screws, Nuts & Bolts, Renewal of Rubber Coaming etc. | 1 | Nos | |
5156 | 87.64 | Configuration of Logic Controller Ckts, PCB and Repairs etc. | 1 | Nos | |
5157 | 87.65 | Replacement of PCBs/Stabilizers with Components, clean parts/area using OKS 2201 | 1 | Nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail