Aurangabad Municipal Corporation has published Doing Maintenance Work Of Water Supply Pipe Line At Various Places In Zone No . 01. Submission Date for this Tender is 23-10-2019. Bolts Tenders in AMC E-TENDER CELL PHASE - 3 BUILDING, AURANGABAD Maharashtra. Bidders can get complete Tender details and download the document.
Name of Work: Doing maintainance work of water supply pipe line at various places in Zone No.01 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Excavation for foundation / pipe trenches in soft rock and old cement etc comp.Lift 0 to 1.50 M MJP/DSR/2018-2019/ Page No.34 I.No.5 | 1 | 355 | Cum |
2 | 2 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road etc compLift 0 to 1.50 M MJP/DSR/2018-2019/ Page No.34 I.No.3 | 2 | 495 | Cum |
3 | 3 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft etc comp. Lift 0 to 1.50 M MJP/DSR/2018-19/Page no.34 I.No.1 | 3 | 645 | Cum |
4 | 4 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, etc comp. Lift 0 to 1.50 M MJP/DSR/2018-2019/ Page No.35 I.No.7 | 4 | 310 | Cum |
5 | 5 | Providing and Supplying Asbestos Cement Pressure Pipes manufactured and tested as per ISO-160 standards of following class and diameter in standard lengths including cost of all taxes (Central and local), insurance, railway freight, inspection charges, unloading from railway wagon, loading into truck, transporting to departmental store/site, unloading, stacking etc. complete MJP/DSR/2012-2013/Page no.57. I.no. 1 | 5 | 0.001 | Rmt |
6 | 6 | 80mm | 6 | 55 | Rmt |
7 | 7 | 100mm | 7 | 48 | Rmt |
8 | 8 | 150mm | 8 | 37 | Rmt |
9 | 9 | 200mm | 9 | 29 | Rmt |
10 | 10 | Lowering, laying and jointing with CID joints, A.C. pressure pipes and CI or MS specials of following class and diameters including conveyance from stores to site of works, cost of labour and material, giving satisfactory hydraulic testing, etc. as per ISI code, etc. complete but excluding cost of C.I.D. joints, nut bolts, rubber rings. MJP/DSR/2012-2013/ P.No.59 I.no. 4 (A) | 10 | 0.001 | Rmt |
11 | 11 | 80mm | 11 | 55 | Rmt |
12 | 12 | 100mm | 12 | 48 | Rmt |
13 | 14 | 150mm | 14 | 37 | Rmt |
14 | 15 | 200mm | 15 | 29 | Rmt |
15 | 16 | Providing and supplying C.I.detachable joints suitable for A.C. pressure pipes standards of following class and dimeter excluding GST levied by GoI & GoM in all respect, etc. complete. MJP/DSR/2018-2019/Page no. 69 I.no.13 | 16 | 0.001 | No |
16 | 17 | 80mm | 17 | 88 | No |
17 | 18 | 100mm | 18 | 110 | No |
18 | 19 | 150mm | 19 | 98 | No |
19 | 20 | 200mm | 20 | 44 | No |
20 | 21 | Checking & Repairing Private Water connection for removing contamination and choke up and reconnecting the same etc complete | 21 | 190 | No |
21 | 22 | Dissconnection of unauthourised private water connection etc comp | 22 | 45 | No |
22 | 23 | Removing existing cross connection and remaking the same etc complete (70% Rate of making cross connection.) MJP/DSR/2018-2019/Page no.47. I.No.10 | 23 | 0.001 | No |
23 | 24 | 80mm | 24 | 29 | No |
24 | 25 | 100mm | 25 | 45 | No |
25 | 26 | 150mm | 26 | 38 | No |
26 | 27 | 200mm | 27 | 27 | No |
27 | 28 | Removing and refixing the half body of Sluice Valves including excavation, refilling, cost of rubber packing, nut bolts, with gate, gland rope, repair by welding etc complete (70 % Rate of laying Sluice Valves ) MJP/DSR/2018-2019/ Page no.214 I.No.4 | 28 | 0.001 | No |
28 | 29 | 80 mm | 29 | 12 | No |
29 | 30 | 100 mm | 30 | 40 | No |
30 | 31 | 150 mm | 31 | 38 | No |
31 | 32 | 200 mm | 32 | 30 | No |
32 | 33 | 250 mm | 33 | 6 | No |
33 | 34 | 300 mm | 34 | 10 | No |
34 | 35 | 350 mm | 35 | 7 | No |
35 | 36 | 400 mm | 36 | 6 | No |
36 | 37 | 450 mm | 37 | 5 | No |
37 | 38 | 500 mm | 38 | 4 | No |
38 | 39 | Providing and supplying S.S. spindle rod as per standard specifications and suitable for Sluice Valves etc complete. (As Per Market rate ) | 39 | 0.001 | No |
39 | 40 | 80mm | 40 | 5 | No |
40 | 41 | 100mm | 41 | 9 | No |
41 | 42 | 150mm | 42 | 8 | No |
42 | 43 | 200mm | 43 | 12 | No |
43 | 44 | 250mm | 44 | 4 | No |
44 | 45 | 300mm | 45 | 3 | No |
45 | 46 | 350mm | 46 | 5 | No |
46 | 47 | 400 mm | 47 | 4 | No |
47 | 48 | 450 mm | 48 | 3 | No |
48 | 49 | 500 mm | 49 | 2 | No |
49 | 50 | Providing and supplying Gun metal check nut of following diameter of Sluice Valves as per standard specifications, etc. complete | 50 | 0.001 | No |
50 | 51 | 80mm | 51 | 3 | No |
51 | 52 | 100mm | 52 | 5 | No |
52 | 53 | 150mm | 53 | 8 | No |
53 | 54 | 200mm | 54 | 10 | No |
54 | 55 | 250mm | 55 | 6 | No |
55 | 56 | 300mm | 56 | 4 | No |
56 | 57 | 350mm | 57 | 6 | No |
57 | 58 | 400 mm | 58 | 5 | No |
58 | 59 | 450 mm | 59 | 3 | No |
59 | 60 | 500 mm | 60 | 1 | No |
60 | 61 | Repair the gate by welding to make it in orignal position etc comp | 61 | 0.001 | No |
61 | 62 | 100mm | 62 | 8 | No |
62 | 63 | 150mm | 63 | 9 | No |
63 | 64 | 200mm | 64 | 9 | No |
64 | 65 | 300mm | 65 | 7 | No |
65 | 66 | 350mm | 66 | 7 | No |
66 | 67 | 400 mm | 67 | 6 | No |
67 | 68 | 450 mm | 68 | 6 | No |
68 | 69 | Providing and Supplying M.S. clamp for pipes of following diameters etc comp.(As Per Market rate ) | 69 | 0.001 | No |
69 | 70 | 100mm | 70 | 20 | No |
70 | 71 | 150,mm | 71 | 25 | No |
71 | 72 | 200mm | 72 | 15 | No |
72 | 73 | 250mm | 73 | 8 | No |
73 | 74 | 300mm | 74 | 7 | No |
74 | 75 | 350mm | 75 | 7 | No |
75 | 76 | 400mm | 76 | 4 | No |
76 | 77 | 450mm | 77 | 4 | No |
77 | 78 | Providing double flanged Sluice Valves conforming to IS- 2906 / 14846 excluding GST levied by GoI & GoM in all respect,etc. complete. PN-1.0 MJP/DSR/2018-2019/Page no.208 I.No.2 (A) | 78 | 0.001 | No |
78 | 79 | 80 mm | 79 | 5 | No |
79 | 80 | 100 mm | 80 | 6 | No |
80 | 81 | 150 mm | 81 | 8 | No |
81 | 82 | 200 mm | 82 | 3 | No |
82 | 83 | Lowering laying and jointing in position following C.I. D/F and Sluice Valves etc complete. MJP/DSR/2018-2019/Page no.214 I.No.4 | 83 | 0.001 | No |
83 | 84 | 80 mm | 84 | 5 | No |
84 | 85 | 100 mm | 85 | 6 | No |
85 | 86 | 150 mm | 86 | 8 | No |
86 | 87 | 200 mm | 87 | 3 | No |
87 | 88 | Making cross connection to existing distribution main of any type etc comp. MJP/DSR/2018-2019/Page no.47 I.No.10 | 88 | 0.001 | No |
88 | 89 | 100mm | 89 | 5 | No |
89 | 90 | 150mm | 90 | 7 | No |
90 | 91 | 200mm | 91 | 5 | No |
91 | 92 | 250mm | 92 | 3 | No |
92 | 93 | 300mm | 93 | 3 | No |
93 | 94 | Providing and supplying ISI standard CI flanged / S & S specials etc. complete. C) Plain ended/plain ended branch flanged specials - i) 80 mm dia to 300 mm dia MJP/DSR/2018-2019/ Page no.63, I.No.6 (C) | 94 | 350 | Kg |
94 | 95 | Supply of C.I. Mechanical Compression collar coupling suitable for C.I spun pipes ( as per IS-1536 /2001)excluding GST levied by GoI & GoM in all respect MJP/DSR/2018-2019/Page no.234 I.No.25 1 | 95 | 0.001 | No |
95 | 96 | 200mm | 96 | 5 | No |
96 | 97 | 250mm | 97 | 2 | No |
97 | 98 | 300mm | 98 | 3 | No |
98 | 99 | 350mm | 99 | 4 | No |
99 | 100 | 400mm | 100 | 1 | No |
100 | 101 | 450mm | 101 | 1 | No |
101 | 102 | Providing ISI mark G.I. pipes of following class and diameters,excluding GST levied by GoI & GoM in all respect, etc. complete. (IS-1239 / 2004) Heavy Class. MJP/DSR/2018-2019/Page no.85, I.No.1, (C) | 102 | 0.001 | No |
102 | 103 | 50 mm | 103 | 25 | Rmt |
103 | 104 | Lowering, laying and jointing G I pipes and specials of following class and diameter Heavy Class. MJP/DSR/2018-2019/Page no.86, I.No.2 ( C ) | 104 | 0.001 | Rmt |
104 | 105 | 50mm | 105 | 25 | Rmt |
105 | 106 | Providing and supplying GI pipes specials at amount for GI pipe 10% etc comp | 106 | 1 | Rmt |
106 | 107 | Providing and making lead clauked joint with molten lead to cast iron pipes and or specials of all classes and fitting of lead and all joints material etc comp.MJP/DSR/2018-2019/Page no.62 I.no.4 | 107 | 0.001 | Joint |
107 | 108 | 250mm | 108 | 4 | Joint |
108 | 109 | 300mm | 109 | 4 | Joint |
109 | 110 | 350mm | 110 | 4 | Joint |
110 | 111 | 400mm | 111 | 8 | Joint |
111 | 112 | 450mm | 112 | 10 | Joint |
112 | 113 | Dismantlling dead pipe line of MS/RCC/CI/PSC and GI /AC/ PVC/SW/HDPE pipe including cost of necessary etc complete. A) MS/RCC/CI/PSC/DI pipes. MJP/DSR/2018-2019/Page no.48 I.no.11 (A) | 113 | 0.001 | Rmt |
113 | 114 | 100 mm | 114 | 15 | Rmt |
114 | 115 | 150 mm | 115 | 18 | Rmt |
115 | 116 | 200 mm | 116 | 20 | Rmt |
116 | 117 | Lowering laying and jointing DI pipe with SBR gasket etc complete. MJP/DSR/2018-2019/Page no.214 I.No.4 | 117 | 0.001 | Rmt |
117 | 118 | 100mm | 118 | 15 | Rmt |
118 | 119 | 150mm | 119 | 18 | Rmt |
119 | 120 | 200mm | 120 | 20 | Rmt |
120 | 121 | Dewatering the excavated trenches and pools of water in the pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. MJP/DSR/2018-2019/Page no.36 I.no.14 | 121 | 95 | HP/Hr |
121 | 122 | Providing & laying in situ cement concrete M-15/1:2:4 of trap/granite/ quartzite/ gness metal for foundation and bedding including dewatering, compacting and curing etc. complete. MJP/DSR/2018-19/P.NO 41 I no 1 | 122 | 12.02 | Cum |
122 | 123 | Welding in all position with required number of runs, for M.S. pipes internally and externally including wherever necessary, fixing appurtenances and other accessories in connection with pipe laying work as per specification, As per MJP DSR 2018-19, Page no 280 | 123 | 0.001 | Rmt |
123 | 124 | 4 mm plate thickness | 124 | 1 | Rmt |
124 | 125 | 5 mm plate thickness | 125 | 1 | Rmt |
125 | 126 | 6 mm plate thickness | 126 | 1 | Rmt |
126 | 127 | Gas cutting (either square cut or V cut) pipe plates,etc complete MJP/DSR/2018-2019/Page No 285 I No 12 | 127 | 0.001 | Rmt |
127 | 128 | upto 5 mm thickness | 128 | 1 | Rmt |
128 | 129 | Above 5 mm upto 10 mm thickness | 129 | 1 | Rmt |
129 | 130 | Gas cutting holes upto 50 mm dia (for plugs) plates,etc complete MJP/DSR/2018-2019/Page No 286 I No 13 | 130 | 0.001 | Rmt |
130 | 131 | upto 5 mm thickness | 131 | 1 | Rmt |
131 | 132 | Above 5 mm upto 10 mm thickness | 132 | 1 | Rmt |
132 | 133 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc.complete. MJP/DSR/2016-2017/Page no.37 I.No.15 | 133 | 1805 | Cum |