Supply , Erecting , Testing And Commissioning Of Flow Meters For Inlet Water Line Of Ash Water Pump , Etp And Awrs Of Obra Tps , Obra , Electromagnetic Flow Meter For Unit No . 9 , Btps , Hp Pump Outlet Header Water Pipeline Ms Line . Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 300 , Water Flow Rate Max :800 Cubic M/Hr , Wire Housing: Welded Sheet Steel Construction , Header Operating Pressure:12 Kg/ Sq Cm ( Max:20Kg ) , Flow Sensor: Full Bore Type , Temperature Of Water: 20-40 Deg . C , Ambient Temp . : 0-50Deg . C , Power Supply:230 V Ac , Wet Calibrated , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Output: 4 To 20 Ma , Accuracy :+/- 2% Over Complete Velocity Range , Rs485 , Modbus/Hart , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint I, Obra TPS,Obra-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Supply , Erecting , Testing And Commissioning Of Flow Meters For Inlet Water Line Of Ash Water Pump , Etp And Awrs Of Obra Tps , Obra , Electromagnetic Flow Meter For Unit No . 9 , Btps , Hp Pump Outlet Header Water Pipeline Ms Line . Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 300 , Water Flow Rate Max :800 Cubic M/Hr , Wire Housing: Welded Sheet Steel Construction , Header Operating Pressure:12 Kg/ Sq Cm ( Max:20Kg ) , Flow Sensor: Full Bore Type , Temperature Of Water: 20-40 Deg . C , Ambient Temp . : 0-50Deg . C , Power Supply:230 V Ac , Wet Calibrated , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Output: 4 To 20 Ma , Accuracy :+/- 2% Over Complete Velocity Range , Rs485 , Modbus/Hart , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint I. Submission Date for this Tender is 21-10-2019. Connectors Supply Tenders in Obra TPS,Obra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

22119626
Supply , Erecting , Testing And Commissioning Of Flow Meters For Inlet Water Line Of Ash Water Pump , Etp And Awrs Of Obra Tps , Obra , Electromagnetic Flow Meter For Unit No . 9 , Btps , Hp Pump Outlet Header Water Pipeline Ms Line . Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 300 , Water Flow Rate Max :800 Cubic M/Hr , Wire Housing: Welded Sheet Steel Construction , Header Operating Pressure:12 Kg/ Sq Cm ( Max:20Kg ) , Flow Sensor: Full Bore Type , Temperature Of Water: 20-40 Deg . C , Ambient Temp . : 0-50Deg . C , Power Supply:230 V Ac , Wet Calibrated , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Output: 4 To 20 Ma , Accuracy :+/- 2% Over Complete Velocity Range , Rs485 , Modbus/Hart , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint I
Open Tender
Indian
Uttar Pradesh
Obra TPS,Obra
21-10-2019

Tender Details

Corrigendum - Supply , Erecting , Testing And Commissioning Of Flow Meters For Inlet Water Line Of Ash Water Pump , Etp And Awrs Of Obra Tps , Obra , Electromagnetic Flow Meter For Unit No . 9 , Btps , Hp Pump Outlet Header Water Pipeline Ms Line . Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 300 , Water Flow Rate Max :800 Cubic M/Hr , Wire Housing: Welded Sheet Steel Construction , Header Operating Pressure:12 Kg/ Sq Cm ( Max:20Kg ) , Flow Sensor: Full Bore Type , Temperature Of Water: 20-40 Deg . C , Ambient Temp . : 0-50Deg . C , Power Supply:230 V Ac , Wet Calibrated , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Output: 4 To 20 Ma , Accuracy :+/- 2% Over Complete Velocity Range , Rs485 , Modbus/Hart , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb&Spcb ( Detail As Per Nit ) , Electromagnetic Flow Meter For Unit No . 10 & 11 , Btps Hp Pump Outlet Header Water Pipeline Ms Line , Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 350 , Water Flow Rate Max :1500 Cubic M/Hr , Wire Housing: Welded Sheet Steel Construction , Header Operating Pressure:12 Kg/ Sq Cm ( Max:20Kg ) , Flow Sensor: Full Bore Type , Wet Calibrated Temperature Of Water:20-40 Deg . C , Ambient Temp . : 0-50 Deg . C , Power Supply:230 V Ac , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Output: 4 To 20 Ma , Accuracy :+/- 2% Over Complete Velocity Range , Rs485 , Modbus , /Hart , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb&Spcb . ( Detail As Per Nit ) , Electromagnetic Flow Meter For Unit No . 12 & 13 , Btps Hp Pump Outlet Header Water Pipeline Ms Line , Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 300 , Water Flow Rate Max :1500 Cubic M/Hr , Wire Housing: Welded Sheet Steel Construction , Header Operating Pressure:12 Kg/ Sq Cm ( Max:20Kg ) , Flow Sensor: Full Bore Type , Wet Calibrated Temperature Of Water: 20-40 Deg . C , Ambient Temp . : 0-50 Deg . C , Power Supply:230 V Ac , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Output: 4 To 20 Ma , Accuracy :+/- 2% Over Complete Velocity Range , Rs485 , Modbus , /Hart , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb&Spcb . ( Detail As Per Nit ) , Electromagnetic Flow Meter For Awrs Outlet Water Pipeline To Btps Suitable For Ms Line , Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 400 , Mediam Water Wire Housing: Welded Sheet Steel Construction , Wet Calibrated , Flow Capacity Of Water Line 660Meter Cube Per Hr ( Span:0-1000 Meter Cube Per Hr ) . Operating Pressure Max . :6 Kg/ Sq Cm2 , Flow Sensor: Full Bore Type , Temperature Of Water<50 Deg . C , Ambient Temp . : 0-50 Deg . C , Output: 4 To 20 Ma , Rs485 , Modbus , /Hart , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb & Spcb . ( Detail As Per Nit ) , Electromagnetic Flow Meter For Etp Outlet Water Pipeline Suitable For Ms Line , Size: Od: 400 , Flow Sensor: Full Bore Type , Principle: Faraday Laws Of Electromagnetic Induction , Medium : Water , Wet Calibrated , Flow Capacity Of Water Line 550Meter Cubec Per Hr ( Span:0-1000 Meter Cube Per Hr ) , Operating Pressure Max , Kg/Cm2 , Temperature Of Water :<50Deg . C , Ambient Temp . : 0-50 Deg . C , Output: 4 To 20 Ma , Rs485 , Modbus , /Hart , Digital Output , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Accuracy :+/- 2% Over Complete Velocity Range , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb&Spcb . ( Detail As Per Nit ) , Uninterrupted Power Supply 3Kva With Compatible Battery Bank ( Smf Type ) Min Two Hours Back-Up . ( Detail As Per Nit ) , One Central Das With All Required Latest Software And Antivirus To Send The Data To Cpcb & Upspcb ( Compatible To Data Logger ) For Flow Meters Installed In Btps . Central Das Have To Retrieve All The Data Related The Flow Meters And Display Trend , History Both In Integer And Graph Of At Least One Year . . ( Detail As Per Nit ) , Common For All Items Mentioned From Serial No . 1 To 5 , Flow Meter Should Be Of Line Size As Mentioned , Process Connector : Flange Type , Material Of Flange: Carbon Steel , Sorf Counter Flanges Should Be Supplied By Bidder , Earthing /Grounding Ring Material: Hastelloy /Ss-316 , Sensor Transmitter ( Integral Type ) , Ingress Protection:Ip67 , On Screen Display With Configuration Button , Must Show Multiple Reading Like 4-20Ma Signal , Flow In M3/Hour , T/Hr , L/Hr And Totalizer . Output Signal Rs485 Interface Support Digital Communication With Hart/ Modbus Communicator , Dongle/ Net Setter: As Required , Supply Voltage Dc 24V , 4C 2Sq Mm , Signal Cable : 350 Mtr . Power Cable: 30 Mtr . , Optical Cable As Required And All Other Material Required For Installation Like Cable Tray , Mcb , Jb Etc . ( Detail As Per Nit ) , Erection , Installation , Testing & Commissioning Of All Of Above Flow Meters , Connecting The Local Das To Central Das Via Ethernet / Optical Cable/ Lan / P2p Compatible On Turnkey Basis And Training For The Above All Installed System With All The Documentation , Drawing Etc ( Detail As Per Nit ) , Comprehensive Maintenance Contract For Routine , Preventive/Breakdown Maintenance Of The Installed System . ( Detail As Per Nit )

Key Value

Document Fees
INR 1180 /-
EMD
INR 80000.0 /-
Tender Value
INR 42.80 Lakhs /-