Rajasthan State Road Development And Construction Corporation Limited has published Tender For Various Electrical Work At Karni Singh Stadium , Bikaner. Submission Date for this Tender is 10-10-2019. Bolts Tenders in Bikaner Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work :- Various Electrical work at Karni Singh Stadium, Bikaner | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1.01 | Supply and erection of M S swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate in position including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals , cable entry, GI cable sleeve complete as required. The pole shall be fabricated by using ISI mark tube for structural purpose of following height & designation. ( See Table E - 09 for specs. ) | Item 1 | 1e-05 | nos |
2 | 2 | 9.0 Mtr. ( 410 SP - 28 ) | Item 2 | 12 | Nos. |
3 | 3 | Supply, Erection and Fixing of hot dipped galvanised Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles | Item 3 | 1e-05 | nos |
4 | 4 | Single arm overhang | Item 4 | 2 | Nos. |
5 | 5 | Double arm overhang | Item 5 | 12 | Nos. |
6 | 6 | P & F of IP-65 Protected high Power ,LED flood light sYstem with Pressure dliecast aluminium housing , toughened 3lass diffuser with suitable lenses on LED to achieve various beam angles, Z4O volt, 50H2, of high Power LED [ixture supplied with pre wired cable of 1 mtr. Integrated driver shall be high efficiency having efficiency more than 85 o/o and in comPliance to IEC standards/BIS certified. The System level Luminaire efficacy >=100 with High Power LEDs of CRE E/N I CH IAlO S RAM / PH I LI PS/SE OUL make is to be used . LED Driver InPut Voltage AC L10 to 270 V AC with Auto resetting Safery Cut-off. InPut Frequency 50Hzt 3o/o Power Factor >0.95 Driver Efficiency >850/o ,Control Gear Integral Design, THD[l) <t00/o Electrical Connector Must be provided Surge Protection Min >=5KV internal and 10KV external in BOW onwards,Humidiry t\o/o to 900/o RH Working TemP -ZTC to 50C LED Luminaire Specifications: Life Expectancy Equal or more than 50000 burning hrs with Minimum 700/o lumen maintenance.Manufactures Word Mark/Name Engraved/Embossed on die cast housing to allow traceability/authenticity till life of fixture. Fixtures shall be CE complianed' | Item 6 | 1e-05 | nos |
7 | 7 | High Power LED Flood Light 160W | Item 7 | 14 | Nos. |
8 | 8 | High Power LED Flood Light 240W | Item 8 | 26 | Nos. |
9 | 9 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. | Item 9 | 1e-05 | nos |
10 | 10 | 10.0 Sq.mm | Item 10 | 1e-05 | nos |
11 | 11 | 4 core | Item 11 | 670 | Mtr. |
12 | 12 | 50.0 Sq.mm | Item 12 | 1e-05 | nos |
13 | 13 | 3.5 core | Item 13 | 400 | Mtr. |
14 | 14 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. | Item 14 | 1e-05 | nos |
15 | 15 | 2.5 Sq.mm | Item 15 | 1e-05 | nos |
16 | 16 | 4 core | Item 16 | 35 | Mtr. |
17 | 17 | Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone ) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes. | Item 17 | 1e-05 | nos |
18 | 18 | With Pipe in Pipe Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100 micron GI Coating | Item 18 | 1e-05 | nos |
19 | 19 | GI pipe 2000 mm long, 50 / 25mm, Terminal 12 mm GI Strip | Item 19 | 10 | Set |
20 | 20 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. | Item 20 | 1e-05 | nos |
21 | 21 | 8 SWG G.I. ( Hot Dipped ) Wire | Item 21 | 700 | Mtr. |
22 | 22 | 20mm x 3mm G.I. ( Hot Dipped ) Strip | Item 22 | 50 | Mtr. |
23 | 23 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. | Item 23 | 1e-05 | nos |
24 | 24 | Single pole MCB | Item 24 | 1e-05 | nos |
25 | 25 | 6 A to 32 A rating | Item 25 | 48 | Nos. |
26 | 26 | Four pole MCB | Item 26 | 1e-05 | nos |
27 | 27 | 40 A 63 A rating | Item 27 | 5 | Nos. |
28 | 28 | P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required. | Item 28 | 1e-05 | nos |
29 | 29 | 1.5 Sq.mm 3 core flat / Round | Item 29 | 500 | Mtr. |
30 | 30 | SITC of high mast lighting system (as per CP3-TR7/1996 of ILE, UK) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm, mast head frame assembly with full cover, aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. ( See table E - 13 for specs.) | Item 30 | 1e-05 | nos |
31 | 31 | 16.0 Mtr HM (in 2 section) Gr.2 | Item 31 | 1 | Nos. |
32 | 32 | Providing and fixing of IP 65 protectd Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. | Item 32 | 1e-05 | nos |
33 | 33 | 125 mm X 200 mm X 122 mm | Item 33 | 1 | Nos. |
34 | 34 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. | Item 34 | 1e-05 | nos |
35 | 35 | Double door (Three phase) | Item 35 | 1e-05 | nos |
36 | 36 | 4 Way | Item 36 | 2 | Nos. |
37 | 37 | SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator). Interconnection between busbar and swithgeard/cable/shall be rigidy supported and made out by flexible copper wires (up to 125 amp) and by solid bus bar(>125amp) all joints/interconnections of copper busbar shall be dully tinned. clearence between main bus bar and risters/metal parts shall be at least 10 mm additional to width of bus bar is insulated by heat shrikable sleeves earth and neutral by heat of the size of phase bus bar. | Item 37 | 10 | Sqmtr |
38 | 38 | Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. | Item 38 | 1e-05 | nos |
39 | 39 | Electrolytic grade Aluminium bus bar | Item 39 | 25 | Kg. |
40 | 40 | SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. | Item 40 | 1e-05 | nos |
41 | 41 | Digital type | Item 41 | 1 | Nos. |
42 | 42 | SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. | Item 42 | 1e-05 | nos |
43 | 43 | Digital type | Item 43 | 1e-05 | nos |
44 | 44 | Below 500 A | Item 44 | 1 | Nos. |
45 | 45 | SF of Current Transformer , with all necessary support in existing panel including connection etc. as required . | Item 45 | 1e-05 | nos |
46 | 46 | up to 150 / 5 Ratio , 5 VA , class 1 accuracy | Item 46 | 4 | Nos. |
47 | 47 | SF of selector switch of 10 A for voltmeter (4 position ) including making connection etc. as required . | Item 47 | 4 | Each |
48 | 48 | SF of CT linked selector switch of 10 A for Ampere meter (4 position ) including making connection etc. as required . | Item 49 | 4 | Each |
49 | 49 | SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required. | Item 50 | 1e-05 | nos |
50 | 50 | Red/yellow/Green colour | Item 51 | 4 | Each |
51 | 51 | SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required. | Item 52 | 1e-05 | nos |
52 | 52 | With Thermal Magnetic release | Item 53 | 1e-05 | nos |
53 | 53 | up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu | Item 54 | 4 | Each |
54 | 54 | 250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu | Item 55 | 1 | Each |
55 | 55 | 400 Amp ,35 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu | Item 56 | 1 | Each |
56 | 56 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , Painting etc. as required. | Item 57 | 30 | Kg |
57 | 57 | Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed:\n | Item 59 | 9 | Cum |
58 | 58 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. | Item 60 | 1e-05 | nos |
59 | 59 | M10 grade Nominal Mix \n1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). | Item 61 | 6 | Cum |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy