}

Construction Of Sundalpur 33 By 11 Kv Sstn Construction Of 33 By 11 Kv Sstn At Sundalpur Under Tehatta Division Under Nadia Region At Nadia District ., Sundalpur-West Bengal

West Bengal State Electricity Distribution Company Limited has published Construction Of Sundalpur 33 By 11 Kv Sstn Construction Of 33 By 11 Kv Sstn At Sundalpur Under Tehatta Division Under Nadia Region At Nadia District .. Submission Date for this Tender is 30-10-2019. Bolts Tenders in Sundalpur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

21996414
Construction Of Sundalpur 33 By 11 Kv Sstn Construction Of 33 By 11 Kv Sstn At Sundalpur Under Tehatta Division Under Nadia Region At Nadia District .
Tender
Indian
West Bengal
Sundalpur
30-10-2019

Tender Details

Construction Of Sundalpur 33 By 11 Kv Sstn Construction Of 33 By 11 Kv Sstn At Sundalpur Under Tehatta Division Under Nadia Region At Nadia District . , Erection Of 4Pole Structure By 8Mtr Pcc Pole With Pcc Foundation ( 1:3:6 And Size 2X2x6 ) From 1500 Mm Below And Upto 300 Mm Above With Centering , Plastering& Net Finishing Above Ground Level For Base Protection Of Pcc Pole , Fabrication And Fixing Of Gi Structure With Supply Of Gi Nuts And Bolts As Per Drawing And Specification ( Struc . Drg . No . -Re/Ss/39 ) For Gantry Cum Isolator Structure , Erection Of 4Pole Structure By 8Mtr Pcc Pole With Pcc Foundation ( 1:3:6 And Size 2X2x6 ) From 1500 Mm Below And Upto 300 Mm Above With Centering , Plastering& Net Finishing Above Ground Level For Base Protection Of Pcc Pole , Fabrication And Fixing Of Gi Structure With Supply Of Gi Nuts And Bolts As Per Drawing And Specification ( Struc . Drg . No . -Re/Ss/34 ) Forh . L Isolator Structure , Erection Of 4Pole Structure By 8Mtr Pcc Pole With Pcc Foundation ( 1:3:6 And Size 2X2x8 ) From 2500 Mm Below And Upto 300 Mm Above With Centering , Plastering& Net Finishing Above Ground Level For Base Protection Of Pcc Pole , Fabrication And Fixing Of Gi Structure With Supply Of Gi Nuts And Bolts As Per Drawing And Specification ( Struc . Drg . No . -Re/Ss/41 ) Forl . L Isolator Support Structure . , Erection Of 4Pole Structure By 8Mtr Pcc Pole With Pcc Foundation ( 1:3:6 And Size 2X2x8 ) From 2500 Mm Below And Upto 300 Mm Above With Centering , Plastering& Net Finishing Above Ground Level For Base Protection Of Pcc Pole , Fabrication And Fixing Of Gi Structure With Supply Of Gi Nuts And Bolts As Per Drawing And Specification ( Struc . Drg . No . -Re/Ss/38 ) Forl . L End Bus Cum Isolator Support Structure . , Erection Of Double Pole Structure By 9Mtr Pcc Pole With Pcc Foundation ( 1:3:6 And Size 2X2x6 ) With Centering , Plastering& Net Finishing Above Ground Level For Base Protection Of Pcc Pole Including Complete Fittings With Pole And Galvanised Structure As Per Wbsedcl Specified 33/11 Kv Substation Galvanised Structure For 11 Kv Outgoing Bay . , Fixing Of 33Kv Cr Type 400 Amp Isolator Without Earth Switch On Existing Structure Alongwith Fixing Of Isolator Handle And Associated Parts With Proper Adjustment For Smooth Operation By Suppling Necessary Compression Type Connectors , Pads Etc . , Fixing Of 33Kv Cr Type 400 Amp Isolator With Earth Switch On Existing Structure Alongwith Fixing Of Isolator Handle And Associated Parts With Proper Adjustment For Smooth Operation By Suppling Necessary Compression Type Connectors , Pads Etc . , Fixing Of 11Kv Tpgo 400 Amp Isolator On Existing Structure Alongwith Fixing Of Isolator Handle And Associated Parts With Proper Adjustment For Smooth Operation By Suppling Necessary Compression Type Connectors , Pads Etc . , Fixing Of 33Kv Polymer Pin Insulator With Gi Pin On Sub-Station Structure , Fixing Of 33Kv Polymer Disc Insulator With 70 Kn Disc Making With Compression Joint At Isolator Pad And Strain Clamp To Conductor Maintaining Proper Connection /Tension By Suppling Necessary Compression Type Connectors And Pad Etc . On Sub-Station Structure , Fixing Of 42Kv Grade La On Existing Structure , Fixing Of 12Kv Grade La On Existing Structure , Stringging & Sagging Of Wire Bus ( 3Wire System ) With Necessary Connection With Isolator & Other Equipments Including Droper As Per Instruction Of Site Officer With 200Sqmm Acsr ( Panther ) ( To Be Supplied By Wbsedcl ) Including Supply & Fixing Of Different Types Of Compression Type Connectors , Pad Etc . , Stringing And Sagging Of Shielding Wire By Acsr 50 Sq . Mm . , Erection Of 13 Mtr . H-Beam Poles For Shielding , Ht Stay Set Complete With All Fittings , Guy Insulator , Binding Etc . , Supply And Erection Of 11 Kv Cable End Box Supporting Galvanised Fame Work As Per Approved Drawing ( Pln/Dss/85 ) On Existing Foundation . , Erection Of Gi Lt Cable Supporting Frame With Concrete Foundation For Stn . Service Transformer ( Ms Channel , Angle , Flat To Be Supplied From Wbsedcl ) , Installation Of 36Kv , Outdoor Type Vcb With Erection Of Structure On Existing Concrete Foundation With Proper Adjustment And Connection With Ct , Bus Etc . And Allied Workby Suppling Necessary Compression Type Connectors And Pad . , Installation Of Outdoor Type 36Kv Ct On Existing Structure With Proper Adjustment And Connection With Vcb , Bus Etc . And Allied Work By Suppling Necessary Compression Type Connectors And Pad . , Installation Of Outdoor Type 33Kv Pt On Existing Structure With Proper Adjustment And Connection With Bus Etc . And Allied Work By Suppling Necessary Compression Type Connectors And Pad . , Installation Of 33/0 . 400 Kv , 100Kva Station Service Transformer On Existing Concrete Foundation With Connection With Bus And Allied Work By Suppling Necessary Compression Type Connectors And Pad . , Supply & Fixing Of 18Way Outdoor Type Junction Box On Ct Structure . , Supply & Fixing Of 12Way Outdoor Type Junction Box On Pt Structure . , Laying Of 2 . 5Sqmm Copper Control Cable Through Existing Cable Trench/Wall By Fixing Saddle And Dressing For Connection With Dc Battery , Dc Panel , 11Kv Vcb , Ac Panel , 33Kv Cr Panel , Pt , Ct , Power Transformer , 33Kv Vcb Etc . With Necessary Connection And Allied Wire Upto Pre-Commissioning ( Cable Socket , Gland , Ferrul Etc . Will Be Supplied By Contractor ) And Necessary Assistance During Commissioning For 12 Core Cable , Laying Of 2 . 5Sqmm Copper Control Cable Through Existing Cable Trench/Wall By Fixing Saddle And Dressing For Connection With Dc Battery , Dc Panel , 11Kv Vcb , Ac Panel , 33Kv Cr Panel , Pt , Ct , Power Transformer , 33Kv Vcb Etc . With Necessary Connection And Allied Wire Upto Pre-Commissioning ( Cable Socket , Gland , Ferrul Etc . Will Be Supplied By Contractor ) And Necessary Assistance During Commissioning For 8 Core Cable , Laying Of 2 . 5Sqmm Copper Control Cable Through Existing Cable Trench/Wall By Fixing Saddle And Dressing For Connection With Dc Battery , Dc Panel , 11Kv Vcb , Ac Panel , 33Kv Cr Panel , Pt , Ct , Power Transformer , 33Kv Vcb Etc . With Necessary Connection And Allied Wire Upto Pre-Commissioning ( Cable Socket , Gland , Ferrul Etc . Will Be Supplied By Contractor ) And Necessary Assistance During Commissioning For 4 Core Cable , Laying Of 1 . 1Kv Grade 4 Core 120 Sqmm Pvc Armoured Cable Through Existing Cable Trench From Station Service Transformer To Ac Distribution Panel Including End Termination Joints . , Laying Of 11Kv Grade 3X300 Sqmm Xlpe Cable Through Cable Trench ( With Loop ) Including Raiser , Necessary Iron Materials To Be Supplied By Wbsedcl . , Laying Of 11Kv Grade 3X185 Sqmm Xlpe Cable Through Cable Trench ( With Loop ) Including Raiser , Necessary Iron Materials To Be Supplied By Wbsedcl . , Jointing Including Fitting And Fixing Of Heat Shrinkable/Push On Type Terminal Jointing Kit For Following Cable ( Including Supply Of Jointing Kits ) 11Kv Xlpe Ug Cable 300 Sqmm 3Core , Outdoor Type , Jointing Including Fitting And Fixing Of Heat Shrinkable/Push On Type Terminal Jointing Kit For Following Cable ( Including Supply Of Jointing Kits ) 11Kv Xlpe Ug Cable 300 Sqmm 3Core , Indoor Type , Jointing Including Fitting And Fixing Of Heat Shrinkable/Push On Type Terminal Jointing Kit For Following Cable ( Including Supply Of Jointing Kits ) 11Kv Xlpe Ug Cable 185 Sqmm 3Core , Outdoor Type , Jointing Including Fitting And Fixing Of Heat Shrinkable/Push On Type Terminal Jointing Kit For Following Cable ( Including Supply Of Jointing Kits ) 11Kv Xlpe Ug Cable 185 Sqmm 3Core , Indoor Type , Supply & Erection Of Gi Lattice Structure On Existing Concrete With Proper Adjustment For 33Kv Outdoor Ct -4 Nos And Pt-1No . As Per Drawing ( Pln-Dss/57 ) , Fixing Of 11 Kv

Key Value

Document Fees
INR 3540 /-
Tender Value
INR 29.71 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail