| 1 | 1 | Contractor must be depolyed technical qualified, insured, and simillar work experince holder for comprehansive street light system(under ground/overhead), switching system and etc required two team for maintain street light system i.e. line fault, line jumper, highmast cimbing and other not done by EESL including required leader, equipment, tools, sky lift, etc at its own. as per direction of engineering incharge. A. As per requirment of JMC identified and trace out fault from existing under ground cabling system work (Median, Park, road side and etc) pole to pole connectivity supply, line jumper, branch and other work not done by EESL. Replacing as per direction of engineering incharge. B. As per requirment of JMC coordinate with discom related staff dor trace out fault in existing overhead line, any other work given by engineering Incharge. C. As per site requirement contractor must do tree cutting in prescribe time. D. Removing of existing all type luminaries in all respect including loading, unloading and transportation upto JMC store in all direction of engineering incharge. E. Fixing of New/Old street lights luminaires on existing pole, wall in all respect and also connection with road light phase wire and tested ok including loading, unloading, transportation upto site, JMC store F. LT Line spacers must be used by contractor where ever equired at there own G. Immediate attend and take needful action on accedental pole within time as soon possible with all required labour, tools, vechiles as direction of engineering incharge. | BI01010001010000000000000515BI0100001113 | 2 | job |
|---|
| 2 | 2 | Regularly Operation & maintenance of electronics pole mounting dusk down photo cell timer, clock type timer, ON-OFF panel 63/100amp rating Main switch. by required replacment all defective accessories which are burnet,broken and missing such as air break , contractor,(L&T/BCH male) 3 pole MCCB, single pole MCCB, solar plate, electronic/micro controllor, copper strip lead wire insulator, hard ware. Upto supply sources. and also regularly maintain log sheet of time ON-OFF and must be intimate to site incharge / engineering incharge & if any type of need from JUVVNL immediate to inform related office and any type required help to take them. For 25/40/ 63/100 Amp rating(3-Phase/1-phase) | | 45 | nos |
|---|
| 3 | 3 | Regularly Operation & Maintenance of manual main switch operatted ON-OFF & Including all need full replacemen by defective, burnt, and broken accessories such as kitkit fuse, handle unclip fuse wire HRC fuse copper strip connecting rode etc. mainten log sheet and time to time intimate to site incharge / engineer in charge & if any type of need from JUVVNL immediate to inform related office and any type required help to take them. | | 60 | nos |
|---|
| 4 | 4 | Regularly Operation & maintenance of existing fluorescent tube fixture(36/40watt) by need full replacement with all defectives missing and broken accessories in all respect as per direction of engineering incharge. | | 250 | nos |
|---|
| 5 | 5 | Regularly Operation & maintenance of existing sodium & MH fitting (70/150/250watt) including pole/wall/TP pole/oct pole//ZB pole/DL/etc by need full replacement with all defectives missing and broken accessories in all respect as per direction of engineering incharge. | | 1900 | nos |
|---|
| 6 | 6 | Regularly Operatin & Maintanance of existing LEDs lights w including pole/wall/TP pole/oct pole//ZB pole/etc by need full replacement with all defectives missing and broken accessories in all respect as per direction of engineering incharge. | | 1000 | nos |
|---|
| 7 | 7 | Regularly Operation maintanance of existing High-mast lights(SV/MH/LED) in all respect & all accessories with timer switch & panel with replacment of defective accessories as required as per direction of engineering incharge. | BI01010001010000000000000515BI0100001129 | 30 | nos |
|---|