Special Repair In Tmqs Rv Area At Af Stn Palam Under Ge Af Palam Delhi Cantt-10 Provision Of Underground Sump And Pump House Including Demolition Of Overhead Tank In Hv Area At Af Palam Under Ge ( Af ) Palam Delhi Cantt-10, GE (AF) Palam Delhi Cantt-Delhi

Military Engineer Services-MES has published Special Repair In Tmqs Rv Area At Af Stn Palam Under Ge Af Palam Delhi Cantt-10 Provision Of Underground Sump And Pump House Including Demolition Of Overhead Tank In Hv Area At Af Palam Under Ge ( Af ) Palam Delhi Cantt-10. Submission Date for this Tender is 21-10-2019. Demolition Work Tenders in GE (AF) Palam Delhi Cantt Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

21907827
Special Repair In Tmqs Rv Area At Af Stn Palam Under Ge Af Palam Delhi Cantt-10 Provision Of Underground Sump And Pump House Including Demolition Of Overhead Tank In Hv Area At Af Palam Under Ge ( Af ) Palam Delhi Cantt-10
Open Tender
Indian
Delhi
GE (AF) Palam Delhi Cantt
21-10-2019

Tender Details

Special Repair In Tmqs Rv Area At Af Stn Palam Under Ge Af Palam Delhi Cantt-10 Provision Of Underground Sump And Pump House Including Demolition Of Overhead Tank In Hv Area At Af Palam Under Ge ( Af ) Palam Delhi Cantt-10

Key Value

Document Fees
INR 1000 /-
EMD
INR 121645.0 /-
Tender Value
INR 64.43 Lakhs /-

BOQ Items

Name of Work : PROVISION OF UNDERGROUND SUMP AND PUMP HOUSE INCLUDING DEMOLITION OF OVERHEAD TANK IN HV AREA AT AF STATION PALAM UNDER GE (AF) PALAM DELHI CANTT-10
Sl. No. Item Description Item Code / Make Quantity Units
1 1 GENERAL SUMMARY (PART-I TO III)
2 1.01 Lump sum price worked out by the tenderer for Building Works as listed in Sch `A’ Part-I.\n\n 1 Lump sum
3 1.02 Lump sum price worked out by the tenderer for Internal Electrification as listed in Sch `A’ Part -II. 1 Lump sum
4 1.03 Lump sum price worked out by the tenderer for External Water Supply as listed in Sch `A’ Part -III. 1 Lump sum
5 2 SCHEDULE 'A' PART-IV (MISCELLANEOUS ITEMS)\nNote: This Schedule is not pre-priced by MES and the pre-priced rate indicated as "0.00" under Column 6 signifies this fact only.
6 2.01 Internal Electrification \nS&F for Indoor decorative T5 LED Battens - integrated type 20 watt 4 feet white fixture with indoor decorative LED extruded aluminium batten in anodised finish with opal diffuser IP20 with LED rod 20 watt one No etc. complete with all accessories internally pre wired and including connecting up with twin core copper conductor cable complete, all as specified and directed by Engineer-in-Charge. \nMake: Halonix Cat Pt No. HLB-03-20-CW-AL or equivalent in Philips/Havelles. 3 Each
7 2.02 Supply and fixing for MCB, SP, 6-32A ,10KA complete, all as specified and directed by Engineer-in-Charge.\nMake : Havells Cat part No. : DHMGCSPF006-032 Legrand/L&T. 2 Each
8 2.03 Supply and fixing for MCB, SP, 40A ,10KA complete, all as specified and directed by Engineer-in-Charge.\nMake : Havells Cat part No. :DHMGCSPF040 or HPL/Indoasian. 1 Each
9 2.04 Supply and fixing ceiling fan 1200mm sweep, 230 volts (single phase), ISI marked with 5 star rating in 60 watt and provisioning of flexible copper cord of size 1.5 sqmm of required length from ceiling rose to fan inclding connection & proch of MS fastner for hanging of ceiling fan complete, all as specified and directed by Engineer-in-Charge. \nMake - Halonix model No Zephyr. 1 Each
10 2.05 Supply and fix of LED bldg light 45 watt highly efficient LED light made of pressure die cast aluminium housing with high power LED's lens & toughened glass IP 66 with internally prewired incl electronic driver and connecting up with three core flexible copper condutor 1.5 sqmm cable complete all as specified and directed. \nMake Halonix cat Pt No HLSLD-10-45-CWL-I or equivalent in Philips/Havelles.\n 2 Each
11 2.06 M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. 1 Each Job
12 2.07 External Water Supply \nM & L for CI non return valve 100 mm dia without by pass arrangement confirming to IS-5312 part-I, PN 1.0 including nuts, bolts, washers and gaskets complete, all as specified and directed by Engineer-in-Charge. 2 Each
13 2.08 M&L for CI foot valve flanged type including nuts bolts washers and rubber 150 mm dia confirming to IS-4038 complete all as directed by Engineer-in-Charge and including taking out the old unserviceable foot valve and removal from the site and depositing to MES store yard complete, all as specified and directed by Engineer-in-Charge. 2 Each
14 2.09 S&F MCCB 200 Amp, 415 volts, 04 pole, with rupturing capacity 35 KA including mounting arrangement in existing LT panel for new connection complete, all as specified and directed by Engineer-in-Charge. 1 Each
15 2.1 S&F on load change over switch 415 V in sheet metal enclosure 4 pole of capacity 200 Amps complete, all as specified and directed by Engineer-in-Charge. 1 Each
16 2.11 Supply, installation, testing and commissioning of centrifugal pump set, split casing type electric driven having bronze impeller and stainless steel shaft mounted on common hase frame having energy efficient motor suitable capacity TEFC EFF-1 running at 1440 RPM, conforming to IS-12615,coupling guard, coupling etc complete suitable for operation on 415V + 10%, 3 phase, 50 Hz of 34 LPS upto 60mtr head pumps confirming to IS-5199:2002 complete, all as specified and directed by Engineer-in-Charge. \nNote:- (i) The scope of work also include a PCC (1:2:4) foundation as per manufacture specification, suitable MS bolts with nuts, anti vibarating pads, pressure gauge with control valves all as specified and directed by Engr-in-Charge. (ii) suitable size of cable for connection arrangement panel board to motor included the item rate. 2 Each
17 2.12 Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, of capacity 82.5 KVA ,engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc complete, all as specified and directed by Engineer-in-Charge.\n(i) The quoted rate shall be deemed to be inclusive of 12 hour test run at site inclusive of 1 hours on 10% over load in the presence of rep detailed by accepting officer. All arrangements are to be made by the contractor for test at site at his own cost. 1 Each
18 2.13 (A) Alternator :- Standard design alternator rated at 82.5 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3-phase 4 -wire 415 volts 50 Hz, 1500 RPM, self excitedself regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of ±1%. tolerance. The alternator will be suitable for tropical climate and shall generally confirm to IS -13364.\n(i) Insualation class - 'H' + 50%\n(ii) Temperature rise class - 'H'\n(iii) Excitation : Self Excited\n(iv) Regulation performance : The voltage is kept constant with ± 1% manual voltage adjustment within + 5%.\n(v) Frequency regulation : ±1%.\n
19 2.14 (B) Diesel Engine :- Adequate capacity of Diesel engine suitable to 82.5 KVA based on manufacturer’s recommendation, air cooled to drive independently the above Alternator and after considering derating as per site condition after generating and reducing power consumed by accessories, directly coupled through flexible coupling multi cylinder multistroke direct injection, cold starting 1500 RPM as per relevant ISI 10001/10002 with an overload capacity of 10 % for one hour in 12 hours continues running complete for safe handling and operation salient features of accessories shall be as under:-\n(i) Fly wheel with housing.\n(ii) Cooling system :- Mounted radiator with fan & belts. \n(iii) Cooling water pump :-Centrifugal type belt driven. \n(iv) Exhaust System. All as per the standard design of the manufacturer with the folloiwngs : (a) Exhaust gas turbo charger type in built (b) Exhaust manifold (c) Silencer : Residential type (soundless) (d) Belllows.
20 2.15 (v) Fuel System :- Fuel injection system with fuel injections, fuel injection solenoid switch/nozles/governer electronic types capable for 1% speed / frequency regualation. \n (a) Fuel fileters (b) Fuel hoses.\n(vi) Lubricating oil system :-\n (a) Lubricating oil filter (b) Lubricating oil pump.\n(vii) Air Intake System :-\n (a) Air intake manifold (b) Air cleanler dry type.\n(viii) Governor :- Electronic Governor.\n(ix) Startign system. Electric self starter with maintenance firee battery including battery charging alternator.\n(x) Batteries:- Electric self starter with maintenance free battery 12 V suitable capacity as per manufacturer recommendation, including battery charging altornator completewith copper cofector multistranded leads suitable length from self starter to the battery terminals, complete with initial charge and initial fill of electrolyte all as specified and comprising of the following:\n(a) Starter gear ring \n(b) Start and stop push button.\n(c) Ignition key/switch.
21 2.16 (d) Handling and operation :Salient features of accessories shall be as under:\n Radiator with blower fan\n Corrosion inhibitor coolant \n Paper element filters for fuel lub oil and by pass .\n Electronic govener controlled direct fuel injection system\n Fly wheel housing and fly wheel.\n(xi) All as per standard design of the manufacturer and all as directed.\n(xii) Accessories:- AVM pads built or separately mounted to manufacturer base frames. \n(xiii)Base Frame:-Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement perdetermined holes. \n(xiv)Fuel Tank :-of suitable capacity as per standard design made of MS channel with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base outside the acoustic.\n(xv)Controls panel :-\n(a) Load on indication\n(b) load off indication
22 2.17 © Engine start push button\n(d) Engine stop push button\n(e) Fault accept /resetpush button\n(xvi) Battery Charger:- SMPS based unit with inbuilt auto/manual & float boost facility(simulated module power supply)\n(a) DC voltmeter\n(b) DC ammeter\n© Charger rate selector switch \nProtection:-\n(i) Over ioad relay-01 No\n(ii) Earth fault Relay -01 No \n(ii) Under volt release -01 No\n DOL Starter with auto Intermittent system for lub oil priming pump.\n(c) Accoustic enclosure:-Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type . It will consist of accoustically treated panel housed in sheet steel will provide easy access for maintanance ,repairs and operation. The enclosure is custom built to suit conditions with as per manufacturer recommendation.
23 2.18 Auto mains failure panel 415 volts 50 hz suitable for 82.5 KVA DG set mafe out of 16 gauge mild steel sheet factory made cubical type floor mounted front and rear door openable doors with locking arrangement duly powder coated suitable for inclufing the followings:- \n(a) Microprocessor based electronic control box for automatic switching on off of DG set and transfer of load equipped with microprocessor based controller 100% auto, 50 % auto manual and 100 % by pass arrangement adjustable time delay to engine start , standard setting 3 seconds adjustable 0-10 seconds, adjustable time delay on transfer to normal 0-30 second time delay (adjustable) to engine cool down 0-5 minutes , adjustable time felay on transfer to emergancy 0-15 second Make Legrand /ABB/siemens/Kirloskar.\n(b) Microprocessor based auto transfer switch 4 pole of suitable amps 415 Volts 50 Hz with two MCCBs 415 Volts of suitable amps four pole assembled and ready to use complete all as specified .\nAll accessories prewired with suitable size PVC insulated copper conductor cable of approariate size including connections from DG Set all as required at site including foundation as per manufacturer recommendaiton.
24 2.19 The following items are deemed to be included in the rate quoted for all DG sets:-\n(D) Civil Works:-\n All civil works including PCC platform and related to foundations including of panel and equipments including making good the existing structure of ditribed during installation and commissioning of genset. The depth of foundation shall be minimum 300mm with anti vibration pads or as recommended by the manufacturer.\nNote:- The contractor shall arrange for artificial load for testing for final testing of DG set at site and cost is deemed to be included in above offer.
25 2.2 Supply & installation and commissioning and testing of LT panel indoor cubical floor mounted type made out of 1.6 mm thick MSA sheet duly power coated complete with bus bar 300 amps raating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volt 50Hz power supply system suitable for and including the following:-\n\n(a) MCCB 250 Amps 4 pole 50 Hz 415 volt with rupturing capacity 36 KA (ICS = 100% ICU) - 01 Nos.\n(b) MCCB 200 Amps 4 pole 50 Hz 415 volt with rupturing capacity 36 KA (ICS = 100% ICU) - 03 Nos outgoing.\n(c) MCB SPN 32 Amps 230 volt 50Hz 'C' curve type with rupturing capacity 10 KA - 01 No outgoing.\n(d) Indicator set RYB 01 set of 03 Pcs.\n(e) Digital multi function meter suitable for measuring current, voltage, frequency and powerfactor of size 96x96mm of range current rating 200 amps, voltage 0 to 500 volt alongwith CT of appropriate ratio and of make schnieder or equiblent of Make L&T /legrand with in built in selector switch 1 set.\n 1 Each
26 2.21 (f) Fully automatic star delta starter 415 volts, 50 Hz having relay range 60 to 75 Amps alonngwih single phase preventor, over load protection, short circuit protection complete all as specified - 02 Nos\n\nAll accessories prewired with suitable size copper conductor cable /strip and suitable foundation as per manufacture's recommendaiton.`
27 2.22 Supply and laying, joint, testing MS Pipe heavy grade with flanged including flange of suitable thickness, welfing of flange, nuts, bolts of suitable size, rubber gasket with all fittings required at site and laid in trenches/ floor or fixed to wall of the 100 mm bore pipe complete, all as specified and directed by Engineer-in-Charge. 40 RM
28 2.23 Supply and laying, joint, testing MS Pipe heavy grade with flanged including flange of suitable thickness, welfing of flange, nuts, bolts of suitable size, rubber gasket with all fittings required at site and laid in trenches/ floor or fixed to wall of the 150 mm bore pipe complete, all as specified and directed by Engineer-in-Charge. 60 RM
29 2.24 M&L for earthing complete with galvanised iron earth plate electrode 600X600X6mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth strip of 32x6 mm by means of nuts, bolts and washers etc made out of galvanised iron including necessary excavation and earth work, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover, funnel, GI protection pipe etc all as shown in electrical plate No.3 of MES schedule Part-I and as specified and testing on completion. complete all as specified and directed by Engineer-in-Charge. \nNote:- GI strip upto 7.5 m is deemed to be included in the quoted rate and beyond 7.5 m will be measured and paid separately under relevant items. 12 Each
30 2.25 Demolition/Dismantling of RCC frame structure of building No. P/93 upto GL only including taking down of MS staircase , ladder etc (RCC over Head Tank Capacity 100000 Gallon). and removing the debris to a distance exc 25.00KM and not exc 30.00 KM including loading,unloading and make up the site clear in all respect .\nNote :- (a) Tank shall be demolished up to GL/Plinth level only.\n(b) Taking down, refixing and credit sch of CI pipes i. e inlet, outlet, washout and overflow pipes have been considered in water supply section. \n(c) Unserviceable items/Serviceable items such as scrap iron/reinforcement,etc what ever obtained from demolition shall be contractors property against 'Sch of Credit' (Except CI pipes inlet,outlet,overflow and washout).\n(d) Bidder is advised to visit the above site before quoting the tender.\n(e) The contractor will demolish the OHT in such way that it does not damage any near by structure.\n(f) The Demolition of OHT will commenced from top to bottom gradually. All T & P to be used for demolition shall be got approved from GE in writing before commencement of demolition work. 1 Each