| 1 | 1 | Dismantling old plaster or pointing, racking out joints, cleaning and preparing the surface for re-plastering or re-pointing including disposal of rubbish to the dumping ground with all lifts and up lead of 50 m Complete as per direction of Engineer in change. | 1 | 715.39 | SQM |
|---|
| 2 | 2 | Dismantling G.S sheet roofing in/c ridges, hips, valleys gutters wind ties etc. In/c dismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and up to a lead of 50 m as etc. complete as per direction of the engineer-in charge. | 2 | 560.72 | SQM |
|---|
| 3 | 3 | Dismantling doors and windows and clerestory windows (steel or wood) shutter including stacking of serviceable materials and unserviceable materials separately with all lifts and up-to a lead of 50 m etc. Complete as per direction of the Engineer –in-charge. | 3 | 163 | Nos |
|---|
| 4 | 4 | Dismantling all kinds of bamboo ceiling, walling, machan etc. including stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50 m as directed by the Engineer-in-charge. | 4 | 113.82 | SQM |
|---|
| 5 | 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material with all lifts and up-to 50 m lead etc. Complete as per direction of the Engineer-in-charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) | 5 | 3.44 | CUM |
|---|
| 6 | 6 | Providing corrugated G.S sheet roofing including vertical curved surface fixed with polymer coated J or L hooks 8 mm dia. bolts with bitumen and G.I limpet washer or with G.I. limpet washer fitted with lead and in/c a coat of approved steel primer and two coats of approved paint on over lapping of sheet complete (up to any pitch in horizontal /vertical or curved surface) exl. The cost of purling, rafters and trusses & in/c cutting to size and shape wherever required.- 0.63 mm thick with zinc coating not less than 275gm/m2\n | 6 | 560.72 | SQM |
|---|
| 7 | 7 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J. or L hooks,bolts and nuts 8 mm dia.G.I.limpet and bitumen washers including a coat of approved paint complete. 0.63mm thick with zinc coating not less than 275gm/m | 7 | 156.5 | MTR |
|---|
| 8 | 8 | Grading roof for water proofing treatment [Payment shall be made after submission of the product performance shall carry guaranteed for 7 years against any leakage] complete as required as per direction of the Engineer-in-charge with : (a)Cement concrete 1:2:4 ( 1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size ). | 8 | 5.23 | CUM |
|---|
| 9 | 9 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS :702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final courseof stone grit 6 mm and down size or peasized gravel spread at 6 cubic decimeter per square metre, including preparation ofsurface but excluding grading complete as required as per direction of the Engineer-in-charge with : Bitumen felt (hessian base) type 3 grade I conforming to IS : | 9 | 139.5 | SQM |
|---|
| 10 | 10 | Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. complete. 25 mm thick with 12.5 mm stone aggregate | 10 | 137.56 | CUM |
|---|
| 11 | 11 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge: With cement mortar 1:3 ( 1 cement : 3 fine sand ). | 11 | 36.88 | SQM |
|---|
| 12 | 12 | Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete. 40mm thick. | 12 | 551.81 | SQM |
|---|
| 13 | 13 | Providing and fixing muli bamboo champakampa tarja (75mm wide)ceiling, strengthening with single split bamboo battens ( both side ) at 300 mm centre to centre and tied with G.I. wire 1.0 mm complete (over required beams or fixed with a frame of suitable type,which will be paid separately) as per specification. | 13 | 113.82 | SQM |
|---|
| 14 | 14 | Providing wood work in frames of false ceiling , partitions, etc. sawn and put up in position :karai wood | 14 | 0.41 | CUM |
|---|
| 15 | 15 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : Sal Wood | 15 | 0.304 | CUM |
|---|
| 16 | 16 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls, cutting masonry / RCC / CC for hold fasts, embedding hold fasts in cement concrete blocks with cement concrete 1 :\n3 : 6 ( 1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size ) painting two coats of coal tar to sides of chowkhats and making good the damages to walls and floors as required including\ndisposal of rubbish to the dumping ground with all leads and lifts complete as per direction of the Engineer in charge:- Door chowkhats. | 16 | 9 | EACH |
|---|
| 17 | 17 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) Doors | 17 | 66 | NO. |
|---|
| 18 | 18 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be\npaid separately): 12 mm thick natural colour insulating board | 18 | 396.54 | SQM |
|---|
| 19 | 19 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required .Using M.S. angels 40x40x6 mm for diagonal braces. Sqm. Using M.S. angels 40x40x6 mm for diagonal braces. Doors | 19 | 39.38 | SQM |
|---|
| 20 | 20 | Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge. Local Teak wood | 20 | 207.19 | CUM |
|---|
| 21 | 21 | Providing and fixing precast chequered terrazo tiles 22 mm thick with graded marble chips of size upto 6 mm, laid on floors, footpath & courtyard on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and polishing complete. In dark shade using ordinary cement | 21 | 9 | SQM |
|---|
| 22 | 22 | Providing and laying 1st quality ceramic glazed floor tiles of approved size conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades as approved by Engineer-in-chargeover 20 mm thick bed of cement mortar 1 : 4 (1 cement : 4 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete. Ceramic Glazed Tiles 1st quality 300 x 300mm in all shades and designs | 22 | 36.51 | SQM |
|---|
| 23 | 23 | 12mm cement plaster of mix. 1:4 (1 cement : 4 fine sand) | 23 | 681.31 | SQM |
|---|
| 24 | 24 | 6 mm cement plaster of mix- 1:4 (1 cement : 4 fine sand) | 24 | 96.2 | SQM |
|---|
| 25 | 25 | Applying priming coat including cost of materials required. With ready mixed pink primer of approved brand and manufacture on wood work (hard & soft wood). | 25 | 587.36 | SQM |
|---|
| 26 | 26 | Painting on G.S. sheet with synthetic enamel paint ( one or more coats ) of approved brand and manufacture of\nrequired colour to give an even shade on old work including preparation of surface as required complete as per direction of the Engineer in charge:- | 26 | 2829.95 | SQM |
|---|
| 27 | 27 | Painting on wood work with oil type wood preservative (one or more coats ) of approved brand and manufacture on old work including preparation of surface as required complete as per direction of the Engineer in charge. | 27 | 927.36 | SQM |
|---|
| 28 | 28 | Finishing with epoxy paint ( one or more coats ) of approved brand and manufacture at all locations prepared and applied as per manufacturer's specification on old work including preparation of surface etc. as required complete as per direction of the Engineer in charge:- | 28 | 693.57 | SQM |
|---|
| 29 | 29 | Distempering with dry distemper of approved brand and manufacture and of required shade on old work ( one or\nmore coats ), to give an even shade as required complete as per direction of the Engineer in charge. | 29 | 4938.01 | SQM |
|---|
| 30 | 30 | White washing with lime to give an even shade on old work as required complete as per direction of the Engineer in charge. one or more coat. | 30 | 30.72 | SQM |
|---|
| 31 | 31 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge. | 31 | 2507.81 | SQM |
|---|
| 32 | 32 | Finishing walls with premium acrylic smooth exterior paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge. | 32 | 1252.97 | SQM |
|---|
| 33 | 33 | Sand cast iron S&S pipe as per IS: 1729. | 33 | 7 | MTR |
|---|