| 1 | 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. | | 349.65 | Cum |
|---|
| 2 | 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exeeeding 25cm thick in soft/loose soil under floor complete all as specified and directed. | | 187.27 | Cum |
|---|
| 3 | 3 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and directed. | | 162.38 | Cum |
|---|
| 4 | 4 | M&L sand cushioning for cable protection complete all as specified and directed. | | 139.86 | Cum |
|---|
| 5 | 5 | Supply and laying Sub Class \"B\" Bricks Designation 75 as in Cable Protection complete all as specified and as directed. | | 14.8 | Per 1000 Nos |
|---|
| 6 | 6 | Taking out / taking down old unserviceable under ground cable of any size complete with and including taking out brick protection and GI pipes as applicable complete all as specified and directed.\nNote : Excavation and earth work shall be measured and paid separately. | | 1700 | Rm |
|---|
| 7 | 7 | M&L including testing XPLE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 Sqmm, 3.5 core complete all as specified and directed. | | 100 | Rm |
|---|
| 8 | 8 | All as per Item Ser No- 7 here-in-before but size of cable 120 Sqmm, 3.5 core. | | 200 | Rm |
|---|
| 9 | 9 | All as per Item Ser No-7 here-in-before but size of cable 95 Sqmm, 3.5 core. | | 200 | Rm |
|---|
| 10 | 10 | All as per Item Ser No- 7 here-in-before but size of cable 50 Sqmm, 3.5 core. | | 300 | Rm |
|---|
| 11 | 11 | All as per Item Ser No- 7 here-in-before but size of cable 25 Sqmm, 3.5 core. | | 200 | Rm |
|---|
| 12 | 12 | All as per Item Ser No- 7 here-in-before but size of cable 16 Sqmm, 4 core. | | 350 | Rm |
|---|
| 13 | 13 | All as per Item Ser No- 7 here-in-before but size of cable 6 Sqmm, 4 core. | | 350 | Rm |
|---|
| 14 | 14 | M & L for locating fault in 11 KV UG cable with help of fault locating machine/ vehicle by injecting necessary high voltage to fault cable complete all as specified and directed. | | 1 | Each Job |
|---|
| 15 | 15 | M & L for locating fault in 1.1 KV UG cable with help of foult locating machine/ vehicle by injecting necessary Low voltage to fault cable complete all as specified and directed. | | 20 | Each Job |
|---|
| 16 | 16 | Taking out / taking down old unserviceable under ground cable of any size and from any location , keeping in safe custody and relaying with old bricks and sand & connecting after replacement of straight through joint complete all as specified and directed. \nNote : \n1. Excavation & earth work and joint kit shall be measured and paid separately.\n2. Cost of taking out joint is included in the unit rate of this item.\n3. Joint kit shall be measured and paid separately. | | 150 | Rm |
|---|
| 17 | 17 | M&L straight through joint, heat shrinkable type suitable for LT under ground cable of size 70sqmm to 150 sqmm, 3.5 core complete all as specified and directed. | | 5 | Each |
|---|
| 18 | 18 | M&L straight through joint, heat shrinkable type suitable for LT under ground cable of size 185 sqmm to 300 sqmm, 3.5 core complete all as specified and directed. | | 5 | Each |
|---|
| 19 | 19 | S&F factory made Bus bar chamber of size 900mm(h) X800mm (w) x 70000mm(d), 4 strip aluminium bus bar of size 600 Amps rating for phase and neutral, 400mm long, duly fixed on porcelain insulator made out of 3.15 mm thick M.S. sheet and with proper weather protection( rain protection canopy) having four legs of 1.5 m with angle iron 80mm X 80mm X 5mm thick on floor with PCC foundation 450mm X 350mm X 250mm, type B1 (1 : 2 : 4) (using 20mm crushed stone aggregate), duly powder coated paint having two parts front opening door including earth terminal point, cable connection and including taking down / dismantling existing bus bar chamber complete all as directed. | | 1 | Each |
|---|
| 20 | 20 | Taking down carefully unserviceable street light fitting form pole/ building/watch tower/sunshelter, repair the same and re-fixing on the exiting location including cleaning and electrically connected and testing complete all as specified and as directed. \nNote : (i) Spare / fittings though replaced shall be measured and paid for separately as supply only.\n(ii) Contractor shall provide trolley mounted ladder of required height including other T&P required for repair of street light and unit rate of this item includes this element and nothing extra shall be admissible on this account. | | 100 | Each Job |
|---|
| 21 | 21 | Supply only LED driver and Surge protector suitable for 45 Watt open type complete all as specified as directed. | | 40 | Each |
|---|
| 22 | 22 | Supply only LED driver and Surge protector suitable for 72 Watt open type complete all as specified as directed. | | 40 | Each |
|---|
| 23 | 23 | Supply only LED driver and Surge protector suitable for 120 Watt open type complete all as specified as directed. | | 20 | Each |
|---|
| 24 | 24 | Supply only LED driver and Surge protector suitable for 200 Watt open type complete all as specified as directed. | | 20 | Each |
|---|
| 25 | 25 | S&F in repair 45 watt LED street light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning ,over voltage & short circuit, IP66 Protection complete all as specified and directed. \nMake Crompton cat no LSTP-45-CDL-M or eqv in Bajaj /Philips/Wipro | | 90 | Each |
|---|
| 26 | 26 | S&F in repair 12 watt LED street light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning ,over voltage & short circuit, IP66 Protection complete all as specified and directed. \nMake Crompton cat no LSTS-12-CDL or eqv in Bajaj /Philips/Wipro | | 30 | Each |
|---|
| 27 | 27 | S&F in repair 50 watt LED flood light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning ,over voltage & short circuit, IP66 Protection complete all as specified and directed. \nMake Crompton cat no LFLE-50-CDL or eqv in Bajaj /Philips/Wipro | | 4 | Each |
|---|
| 28 | 28 | S&F in repair 20 watt LED Post top fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning ,over voltage & short circuit, IP66 Protection complete all as specified and directed. \nMake Crompton cat no LTPH-20-CDL or eqv in Bajaj /Philips/Wipro | | 12 | Each |
|---|
| 29 | 29 | S&F in repair 120 watt LED flood light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning ,over voltage & short circuit, IP66 Protection complete all as specified and directed. \nMake Crompton cat no LFLN-120-CDL/60 or eqv in Bajaj /Philips/Wipro | | 6 | Each |
|---|
| 30 | 30 | S&F in repair 3P Module, 24 hours hours program, Programmable every 15 min current capacity 16 A , with 1 changeover(1CO) with complete testing & commissioning complete all as specified and directed.\nMake. Indoasian/L&T/Standadrd | | 8 | Each |
|---|
| 31 | 31 | S&F in repair Power contactors 3P, 32 Amp coil voltage 230V AC complete all as specified and directed. | | 7 | Each |
|---|
| 32 | 32 | S&F in repair sheet metal enclosures single door type phasphatised power painted for DB where MCB’s to be used SPN 2 way with copper 200 Amps rated bus door 415V fixed concealed to wall surface complete all as directed. | | 4 | Each |
|---|
| 33 | 33 | S&F in repair 'C' series TPN MCB 63 Amp, 10 KA complete all as specified and directed. \n | | 7 | Each |
|---|
| 34 | 34 | S&F in repair 'C' series SPN MCB 40 Amp, 10 KA complete all as specified and directed. \n | | 7 | Each |
|---|