Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Supply , Erecting , Testing And Commissioning Of Flow Meters For Inlet Water Line Of Ash Water Pump , Etp And Awrs Of Obra Tps , Obra. Submission Date for this Tender is 10-10-2019. Connectors Supply Tenders in Obra TPS,Obra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21876538
Supply , Erecting , Testing And Commissioning Of Flow Meters For Inlet Water Line Of Ash Water Pump , Etp And Awrs Of Obra Tps , Obra
Open Tender
Indian
Uttar Pradesh
Obra TPS,Obra
10-10-2019

Tender Details

Supply , Erecting , Testing And Commissioning Of Flow Meters For Inlet Water Line Of Ash Water Pump , Etp And Awrs Of Obra Tps , Obra , Electromagnetic Flow Meter For Unit No . 9 , Btps , Hp Pump Outlet Header Water Pipeline Ms Line . Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 300 , Water Flow Rate Max :800 Cubic M/Hr , Wire Housing: Welded Sheet Steel Construction , Header Operating Pressure:12 Kg/ Sq Cm ( Max:20Kg ) , Flow Sensor: Full Bore Type , Temperature Of Water: 20-40 Deg . C , Ambient Temp . : 0-50Deg . C , Power Supply:230 V Ac , Wet Calibrated , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Output: 4 To 20 Ma , Accuracy :+/- 2% Over Complete Velocity Range , Rs485 , Modbus/Hart , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb&Spcb ( Detail As Per Nit ) , Electromagnetic Flow Meter For Unit No . 10 & 11 , Btps Hp Pump Outlet Header Water Pipeline Ms Line , Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 350 , Water Flow Rate Max :1500 Cubic M/Hr , Wire Housing: Welded Sheet Steel Construction , Header Operating Pressure:12 Kg/ Sq Cm ( Max:20Kg ) , Flow Sensor: Full Bore Type , Wet Calibrated Temperature Of Water:20-40 Deg . C , Ambient Temp . : 0-50 Deg . C , Power Supply:230 V Ac , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Output: 4 To 20 Ma , Accuracy :+/- 2% Over Complete Velocity Range , Rs485 , Modbus , /Hart , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb&Spcb . ( Detail As Per Nit ) , Electromagnetic Flow Meter For Unit No . 12 & 13 , Btps Hp Pump Outlet Header Water Pipeline Ms Line , Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 300 , Water Flow Rate Max :1500 Cubic M/Hr , Wire Housing: Welded Sheet Steel Construction , Header Operating Pressure:12 Kg/ Sq Cm ( Max:20Kg ) , Flow Sensor: Full Bore Type , Wet Calibrated Temperature Of Water: 20-40 Deg . C , Ambient Temp . : 0-50 Deg . C , Power Supply:230 V Ac , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Output: 4 To 20 Ma , Accuracy :+/- 2% Over Complete Velocity Range , Rs485 , Modbus , /Hart , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb&Spcb . ( Detail As Per Nit ) , Electromagnetic Flow Meter For Awrs Outlet Water Pipeline To Btps Suitable For Ms Line , Principle: Faraday Laws Of Electromagnetic Induction , Size: Nb 400 , Mediam Water Wire Housing: Welded Sheet Steel Construction , Wet Calibrated , Flow Capacity Of Water Line 660Meter Cube Per Hr ( Span:0-1000 Meter Cube Per Hr ) . Operating Pressure Max . :6 Kg/ Sq Cm2 , Flow Sensor: Full Bore Type , Temperature Of Water<50 Deg . C , Ambient Temp . : 0-50 Deg . C , Output: 4 To 20 Ma , Rs485 , Modbus , /Hart , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Digital Output , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb & Spcb . ( Detail As Per Nit ) , Electromagnetic Flow Meter For Etp Outlet Water Pipeline Suitable For Ms Line , Size: Od: 400 , Flow Sensor: Full Bore Type , Principle: Faraday Laws Of Electromagnetic Induction , Medium : Water , Wet Calibrated , Flow Capacity Of Water Line 550Meter Cubec Per Hr ( Span:0-1000 Meter Cube Per Hr ) , Operating Pressure Max , Kg/Cm2 , Temperature Of Water :<50Deg . C , Ambient Temp . : 0-50 Deg . C , Output: 4 To 20 Ma , Rs485 , Modbus , /Hart , Digital Output , Display: Instantaneous Flow Rate ( Cubic M/Hr ) , Cumulative Flow Totalizer ( Cubic M ) , Record Error Function E . G . Alarm , Disconnection Etc . , Accuracy :+/- 2% Over Complete Velocity Range , Certification: Ip 67 For Flow Transmitter And Ip 68 For Flow Sensor , Teflon Coated/ Anticorrosive Paint Inside , Compatible To Data Logger To Communicate With Cpcb&Spcb . ( Detail As Per Nit ) , Uninterrupted Power Supply 3Kva With Compatible Battery Bank ( Smf Type ) Min Two Hours Back-Up . ( Detail As Per Nit ) , One Central Das With All Required Latest Software And Antivirus To Send The Data To Cpcb & Upspcb ( Compatible To Data Logger ) For Flow Meters Installed In Btps . Central Das Have To Retrieve All The Data Related The Flow Meters And Display Trend , History Both In Integer And Graph Of At Least One Year . . ( Detail As Per Nit ) , Common For All Items Mentioned From Serial No . 1 To 5 , Flow Meter Should Be Of Line Size As Mentioned , Process Connector : Flange Type , Material Of Flange: Carbon Steel , Sorf Counter Flanges Should Be Supplied By Bidder , Earthing /Grounding Ring Material: Hastelloy /Ss-316 , Sensor Transmitter ( Integral Type ) , Ingress Protection:Ip67 , On Screen Display With Configuration Button , Must Show Multiple Reading Like 4-20Ma Signal , Flow In M3/Hour , T/Hr , L/Hr And Totalizer . Output Signal Rs485 Interface Support Digital Communication With Hart/ Modbus Communicator , Dongle/ Net Setter: As Required , Supply Voltage Dc 24V , 4C 2Sq Mm , Signal Cable : 350 Mtr . Power Cable: 30 Mtr . , Optical Cable As Required And All Other Material Required For Installation Like Cable Tray , Mcb , Jb Etc . ( Detail As Per Nit ) , Erection , Installation , Testing & Commissioning Of All Of Above Flow Meters , Connecting The Local Das To Central Das Via Ethernet / Optical Cable/ Lan / P2p Compatible On Turnkey Basis And Training For The Above All Installed System With All The Documentation , Drawing Etc ( Detail As Per Nit ) , Comprehensive Maintenance Contract For Routine , Preventive/Breakdown Maintenance Of The Installed System . ( Detail As Per Nit )

Key Value

Document Fees
INR 1180 /-
EMD
INR 80000.0 /-
Tender Value
INR 42.80 Lakhs /-

BOQ Items

Name of Materials: Supply, erecting, testing & commissioning of flow meters for inlet water line of ash water pump, ETP & AWRS of Obra TPS,Obra .
Sl. No. Item Description Item Code / Make Qty. Units
1 1 Electromagnetic Flow Meter for Unit No. 9, BTPS, HP Pump outlet header water pipeline MS line. Principle: Faraday Law's of electromagnetic Induction, Size: NB 300,Water Flow Rate Max :800 cubic M/hr ,wire housing: welded sheet steel construction, Header operating pressure:12 Kg/ sq cm(Max:20Kg), Flow Sensor: full bore type, Temperature of water: 20-40 Deg. C, Ambient Temp.: 0-50Deg. C, Power Supply:230 V AC, wet calibrated, Display: Instantaneous flow rate (cubic m/hr), Cumulative Flow totalizer (cubic m), Record error function e.g. Alarm, Disconnection etc., Output: 4 to 20 mA, Accuracy :+/- 2% over complete velocity range , RS485,Modbus/HART, digital output, certification: IP 67 for flow transmitter and IP 68 for flow sensor, Teflon coated/ Anticorrosive paint inside, compatible to Data logger to communicate with CPCB&SPCB (Detail as per NIT) item01 1 Sets
2 2 Electromagnetic Flow Meter for Unit No. 10 & 11, BTPS HP Pump outlet header water pipeline MS line, Principle: Faraday Law's of electromagnetic Induction, Size: NB 350,Water Flow Rate Max :1500 cubic M/hr ,wire housing: welded sheet steel construction, Header operating pressure:12 Kg/ sq cm(Max:20Kg), Flow Sensor: full bore type, wet calibrated Temperature of water:20-40 Deg. C, Ambient Temp.: 0-50 Deg. C, Power Supply:230 V AC, Display: Instantaneous flow rate(cubic m/hr),Cumulative flow totalizer (cubic M), Record error function e.g. Alarm, Disconnection etc., Output: 4 to 20 mA, Accuracy :+/- 2% over complete velocity range , RS485,Modbus,/HART, digital output, certification: IP 67 for flow transmitter and IP 68 for flow sensor, Teflon coated/ Anticorrosive paint inside, compatible to Data logger to communicate with CPCB&SPCB. (Detail as per NIT) item02 1 Sets
3 3 Electromagnetic Flow Meter for Unit No. 12 & 13, BTPS HP Pump outlet header water pipeline MS line, Principle: Faraday Law's of electromagnetic Induction, Size: NB 300,water flow rate Max :1500 cubic M/hr ,wire housing: welded sheet steel construction, Header operating pressure:12 Kg/ sq cm(Max:20Kg), Flow Sensor: full bore type, wet calibrated temperature of water: 20-40 Deg. C, Ambient Temp.: 0-50 Deg. C, Power Supply:230 V AC, Display: Instantaneous flow rate(cubic m/hr), Cumulative Flow totalizer (cubic M), Record error function e.g. Alarm, Disconnection etc., Output: 4 to 20 mA, Accuracy :+/- 2% over complete velocity range, RS485,Modbus,/HART, digital output, Certification: IP 67 for flow transmitter and IP 68 for flow sensor, Teflon coated/ Anticorrosive paint inside, compatible to Data logger to communicate with CPCB&SPCB. (Detail as per NIT) item03 1 Sets
4 4 Electromagnetic Flow Meter for AWRS outlet water pipeline to BTPS suitable for MS line, Principle: Faraday Law's of electromagnetic Induction, Size: NB 400,Mediam water wire housing: welded sheet steel construction, Wet calibrated , Flow capacity of water line 660meter Cube Per Hr (Span:0-1000 meter Cube per Hr). Operating pressure Max.:6 Kg/ sq cm2, Flow Sensor: full bore type, Temperature of water<50 Deg. C, Ambient Temp.: 0-50 Deg. C, Output: 4 to 20 mA, RS485,Modbus,/HART, Display: Instantaneous flow rate(cubic M/hr),Cumulative flow totalizer (cubic m), Record error function e.g. Alarm, disconnection etc., digital output, certification: IP 67 for flow transmitter and IP 68 for flow sensor, Teflon coated/ Anticorrosive paint inside, compatible to Data logger to communicate with CPCB & SPCB.(Detail as per NIT) item04 1 Sets
5 5 Electromagnetic Flow Meter for ETP Outlet water pipeline suitable for MS line, Size: OD: 400, Flow sensor: full bore type, Principle: Faraday Law's of electromagnetic Induction ,Medium : water , wet calibrated , Flow capacity of water line 550meter cubec per hr (Span:0-1000 meter cube per hr), operating pressure Max, Kg/cm2, Temperature of water :<50Deg. C, Ambient Temp.: 0-50 Deg. C, Output: 4 to 20 mA, RS485,Modbus,/HART, digital output, Display: Instantaneous flow rate(cubic M/hr),Cumulative Flow totalizer (cubic M), Record error function e.g. Alarm, Disconnection etc. , accuracy :+/- 2% over complete velocity range ,certification: IP 67 for flow transmitter and IP 68 for flow sensor, Teflon coated/ Anticorrosive paint inside, compatible to Data logger to communicate with CPCB&SPCB. (Detail as per NIT) item05 1 Sets
6 6 Uninterrupted Power supply 3KVA with compatible battery bank (SMF Type) Min two hours back-up. (Detail as per NIT) item06 2 Nos
7 7 One Central DAS with all required latest software and antivirus to send the data to CPCB & UPSPCB (compatible to Data logger ) for flow meters installed in BTPS. Central DAS have to retrieve all the data related the flow meters and display Trend, History both in integer and graph of at least one year.. (Detail as per NIT) item07 1 Nos
8 8 Common for all items mentioned from serial no. 1 to 5, Flow meter should be of line size as mentioned, process connector : Flange Type, Material of Flange: Carbon Steel, SORF COUNTER FLANGES should be supplied by bidder , Earthing /Grounding ring material: hastelloy /SS-316, Sensor transmitter (Integral type ), Ingress Protection:IP67, On screen display with configuration button, must show multiple reading like 4-20mA signal, flow in M3/hour, T/Hr, L/Hr and totalizer. Output signal RS485 interface support digital communication with HART/ Modbus communicator, Dongle/ Net setter: as required, supply voltage DC 24V, 4C 2sq mm, signal cable : 350 mtr. Power Cable: 30 mtr. , Optical cable as required and all other material required for installation like cable tray, MCB,JB etc.(Detail as per NIT) item08 1 Nos
9 9 Erection, installation, testing & commissioning of all of Above flow meters, connecting the Local DAS to Central DAS Via Ethernet / Optical cable/ LAN / P2P compatible on turnkey basis and Training for the above all installed system with all the documentation, Drawing etc (Detail as per NIT) item09 1 Job
10 10 Comprehensive Maintenance contract for routine, preventive/breakdown maintenance of the installed system.(Detail as per NIT) item10 36 Months