| 1 | 1 | Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding ,etc. complete as directed. (For Ground Floor)\nItem / Page No : 19 / 285\nAdditional Specifications : The work shall be done as per instructions of Engineer in charge. | Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding ,etc. complete as directed. (For Ground Floor)\nItem / Page No : 19 / 285\nAdditional Specifications : The work shall be done as per instructions of Engineer in charge. | 64.91 | Square Metre |
|---|
| 2 | 2 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. - Flooring (For Ground Floor)\nItem / Page No : 40 / 271\nSpecification No : Bd.M.12\nSpec. Page No : 385\n | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. - Flooring (For Ground Floor)\nItem / Page No : 40 / 271\nSpecification No : Bd.M.12\nSpec. Page No : 385\n | 64.91 | Square Metre |
|---|
| 3 | 3 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor)\nItem / Page No : 34 / 270\nSpecification No : Bd.M.3 B\nSpec. Page No : 380\n | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor)\nItem / Page No : 34 / 270\nSpecification No : Bd.M.3 B\nSpec. Page No : 380\n | 3.83 | Square Metre |
|---|
| 4 | 4 | Providing and fixing Road junction / Information sign board of size 0.90 m x 0.60 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35x35x5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/ white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral / arrows, coated with non pealable crystal clear protective coat retaining 100% reflection including two angle iron post of size 50x50x5 mm of 3.65 m. long inflated at bottom drilled on top and painted in white and black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size as directed by Engineer-in-charge etc. complete. Mild Steel Board with Engineering Grade.\nItem / Page No : 47 / 83\nSpecification No : MoRTH-801\nSpec. Page No : ---\nAdditional Specifications : The work shall be carried out as per instructions of Engineer in charge. | Providing and fixing Road junction / Information sign board of size 0.90 m x 0.60 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35x35x5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/ white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral / arrows, coated with non pealable crystal clear protective coat retaining 100% reflection including two angle iron post of size 50x50x5 mm of 3.65 m. long inflated at bottom drilled on top and painted in white and black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size as directed by Engineer-in-charge etc. complete. Mild Steel Board with Engineering Grade.\nItem / Page No : 47 / 83\nSpecification No : MoRTH-801\nSpec. Page No : ---\nAdditional Specifications : The work shall be carried out as per instructions of Engineer in charge. | 1 | Number |
|---|
| 5 | 5 | Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor.\nItem / Page No : 3 / 0\nAdditional Specifications : Government of Maharashtra, Revenue and Forest Department Gazette Number 67 Dated 15-5-2015 and Government of Maharashtra Public Works Department State Schedule of Rates 2017-18 General Note Number 4.3. | Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor.\nItem / Page No : 3 / 0\nAdditional Specifications : Government of Maharashtra, Revenue and Forest Department Gazette Number 67 Dated 15-5-2015 and Government of Maharashtra Public Works Department State Schedule of Rates 2017-18 General Note Number 4.3. | 1.19 | Cubic Metre |
|---|
| 6 | 6 | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.\nItem / Page No : 4 / 0\nAdditional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.\nItem / Page No : 4 / 0\nAdditional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. | 1 | Job |
|---|
| 7 | 7 | Add 1 % for Insurance\nNon-Dsr Item\nAdditional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | Add 1 % for Insurance\nNon-Dsr Item\nAdditional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | 1 | Lumpsum |
|---|
| 8 | 8 | Add 12 % for GST\nNon-Dsr Item\nAdditional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | Add 12 % for GST\nNon-Dsr Item\nAdditional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | 1 | Lumpsum |
|---|