| 1 | 1 | Scheme 1: Repairs to roof of storeshed Room R1 | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.01 | 15.31 : Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. | BI01010001010000000000000515BI0100001114 | 16.29 | sqm |
|---|
| 3 | 1.02 | 10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001115 | 301.353 | kilogram |
|---|
| 4 | 1.03 | 10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001116 | 225.402 | kg |
|---|
| 5 | 1.04 | 12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001117 | 57.714 | sqm |
|---|
| 6 | 1.05 | 12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm) | BI01010001010000000000000515BI0100001118 | 16 | metre |
|---|
| 7 | 2 | Scheme 2: Repairs to roof of storeshed Rooms R2, R3 & R4 | BI01010001010000000000000515BI0100001119 | | |
|---|
| 8 | 2.01 | 15.31 : Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. | BI01010001010000000000000515BI0100001120 | 15.747 | sqm |
|---|
| 9 | 2.02 | 10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001121 | 183.265 | kilogram |
|---|
| 10 | 2.03 | 10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001122 | 292.253 | kg |
|---|
| 11 | 2.04 | 12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001123 | 38.278 | sqm |
|---|
| 12 | 2.05 | 12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm) | BI01010001010000000000000515BI0100001124 | 22.55 | metre |
|---|
| 13 | 3 | Scheme 3: Repair works to doors, windows, flooring and wall of Room R1 | BI01010001010000000000000515BI0100001125 | | |
|---|
| 14 | 3.01 | 11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete | BI01010001010000000000000515BI0100001126 | 27.585 | sqm |
|---|
| 15 | 3.02 | 13.5.1 : 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1 Cement : 4 coarse sand) | BI01010001010000000000000515BI0100001127 | 1.32 | sqm |
|---|
| 16 | 3.03 | 14.43 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | BI01010001010000000000000515BI0100001128 | 112.144 | sqm |
|---|
| 17 | 3.04 | 14.44 : Distempering with dry distemper of approved brand and manufacture ( one or more coats ) and of required shade on old work to give an even shade. | BI01010001010000000000000515BI0100001129 | 112.144 | sqm |
|---|
| 18 | 3.05 | 15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below | BI01010001010000000000000515BI0100001130 | 5 | each |
|---|
| 19 | 3.06 | 9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood | BI01010001010000000000000515BI0100001131 | 0.14 | cum |
|---|
| 20 | 3.07 | 9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters | BI01010001010000000000000515BI0100001132 | 4.52 | sqm |
|---|
| 21 | 3.08 | 9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood | BI01010001010000000000000515BI0100001133 | 2.434 | sqm |
|---|
| 22 | 3.09 | 9.66.3 : Providing and fixing ISI marked oxidised M.S. handles conforming to IS : 4992 with necessary screws etc. complete:75 mm | BI01010001010000000000000515BI0100001134 | 4 | no |
|---|
| 23 | 3.1 | 9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm | BI01010001010000000000000515BI0100001135 | 4 | no |
|---|
| 24 | 3.11 | 9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete. | BI01010001010000000000000515BI0100001136 | 8 | each |
|---|
| 25 | 3.12 | 9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc | BI01010001010000000000000515BI0100001137 | 2.007 | kg |
|---|
| 26 | 3.13 | od29149/2019_2020/IA : Engaging Man mazdoor for carrying shutter planks from the storeshed and conveying carefully and stacking outside the storeshed pointed out by the departmental officers at site. | BI01010001010000000000000515BI0100001138 | 10 | each |
|---|
| 27 | 3.14 | od29150/2019_2020/IA : Engaging Man mazdoor for carrying shutter planks from outside the storeshed and conveying carefully and stacking inside the storeshed. | BI01010001010000000000000515BI0100001139 | 10 | each |
|---|
| 28 | 4 | Scheme 4: Repair works to doors, windows, flooring and wall of Rooms R2, R3 & R4 | BI01010001010000000000000515BI0100001140 | | |
|---|
| 29 | 4.01 | 11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete | BI01010001010000000000000515BI0100001141 | 24.485 | sqm |
|---|
| 30 | 4.02 | 13.5.1 : 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1 Cement : 4 coarse sand) | BI01010001010000000000000515BI0100001142 | 7.756 | sqm |
|---|
| 31 | 4.03 | 14.43 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | BI01010001010000000000000515BI0100001143 | 125.954 | sqm |
|---|
| 32 | 4.04 | 14.44 : Distempering with dry distemper of approved brand and manufacture ( one or more coats ) and of required shade on old work to give an even shade. | BI01010001010000000000000515BI0100001144 | 212.135 | sqm |
|---|
| 33 | 4.05 | 15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below | BI01010001010000000000000515BI0100001145 | 9 | each |
|---|
| 34 | 4.06 | 9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood | BI01010001010000000000000515BI0100001146 | 0.313 | cum |
|---|
| 35 | 4.07 | 9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters | BI01010001010000000000000515BI0100001147 | 11.107 | sqm |
|---|
| 36 | 4.08 | 9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood | BI01010001010000000000000515BI0100001148 | 7.458 | sqm |
|---|
| 37 | 4.09 | 9.66.3 : Providing and fixing ISI marked oxidised M.S. handles conforming to IS : 4992 with necessary screws etc. complete:75 mm | BI01010001010000000000000515BI0100001149 | 8 | no |
|---|
| 38 | 4.1 | 9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm | BI01010001010000000000000515BI0100001150 | 8 | no |
|---|
| 39 | 4.11 | 9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete. | BI01010001010000000000000515BI0100001151 | 4 | each |
|---|
| 40 | 4.12 | 9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc | BI01010001010000000000000515BI0100001152 | 28.16 | kg |
|---|
| 41 | 5 | Scheme 5: Replacing of damaged shutter planks of vents 1 to 4 from Left bank | BI01010001010000000000000515BI0100001153 | | |
|---|
| 42 | 5.01 | 60.8 : Shutter for check dams- Supplying and providing Thambagam wood shutter planks 5cm thick including cost of materials and labour charges etc complete | BI01010001010000000000000515BI0100001154 | 120 | 10 cud m |
|---|
| 43 | 5.02 | 13.59 : Coal tarring two coats on new work using 0.16 litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. | BI01010001010000000000000515BI0100001155 | 57.601 | sqm |
|---|
| 44 | 6 | Scheme 6: Replacing of damaged shutter planks of vents 8 to 12 from Left bank | BI01010001010000000000000515BI0100001156 | | |
|---|
| 45 | 6.01 | 60.8 : Shutter for check dams- Supplying and providing Thambagam wood shutter planks 5cm thick including cost of materials and labour charges etc complete | BI01010001010000000000000515BI0100001157 | 150 | 10 cud m |
|---|
| 46 | 6.02 | 13.59 : Coal tarring two coats on new work using 0.16 litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. | BI01010001010000000000000515BI0100001158 | 72 | sqm |
|---|