| 1 | 1 | S/E of Hot Dip Galvanized octagonal pole of 3mm thickness with base plate including cost of nut and bolts and all accessories as supplied by the manufacturer including cost of foundation accessories etc. The foundation bolt as per manufacture design should be hot dipped galvanized pole complete with door locking arrangement terminal plate consisting of 2 no. 100A, 4 pole natural link including connection etc. with suitable connecting arrangement for 2 no. MCBs/ kit kat including cost of RCC 1:1.5:3 for foundation of size 0.7 M x 0.7 M x 1.8 M with minimum 8 nos. 12 mm dia longitudinal MS reinforcement rod with rings of 8mm dia not more than 200mm CC for fixing the pole with all labour & material required to complete the job in all respect upto the entire satisfaction of Engineer- in –Charge of the work (make Bajaj/Philips/BPP/UTKARSH/Volmont)\n8 mtr long pole with top dia 70mm and 155 mm bottom dia with base plate of size 225 x 225 x16 mm.\n\n\n\n | BI01010001010000000000000515BI0100001112 | 55 | No. |
|---|
| 2 | 2 | Supply &Erection of PVC copper insulated and sheathed 3 core circular flexible wire.\n2.5sqmm. (80/.20mm)\n | BI01010001010000000000000515BI0100001113 | 550 | Mtr. |
|---|
| 3 | 3 | Supply & erection of PVC unsheathed alum. Conductor cable single core 1100 volt grade. In pipe of suitable size excluding cost and erection of pipe.\nSize 2.50sqmm(1/1.80mm) (RR Kabel, Havells, KEI, Plaza)\n | BI01010001010000000000000515BI0100001114 | 4788 | Mtr. |
|---|
| 4 | 4 | Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required.\nG.I pipe bend 32 mm dia on surface.\n\n\n\n | BI01010001010000000000000515BI0100001115 | 399 | Mtr. |
|---|
| 5 | 5 | S/E of miniature circuit breaker/isolator 240/415 volts in the existing distribution board including making necessary connections.\ni) MCB 06 to 32 Amp SP\n\n\n | BI01010001010000000000000515BI0100001116 | 55 | No. |
|---|
| 6 | 5.1 | iii) MCB 40 to 63 amp. SP (Make L&T, Havells, Merlin Gerin) | BI01010001010000000000000515BI0100001117 | 24 | No |
|---|
| 7 | 6 | Supply and erection of GI pipe for pole/pedestal earthing 40mm dia (B-class) with 12mm dia holes in 100 mm dia bore in earth upto moisture level using proper earth electrode upto full length suitable for pole mounting substation, earthing should be designed with regards to max likely earth fault current\n0-15 mtr. \n | BI01010001010000000000000515BI0100001118 | 402 | Mtr. |
|---|
| 8 | 7 | Extra for using slat and charcoal/ coke for pipe earth electrode as required.\n\n | BI01010001010000000000000515BI0100001119 | 67 | No |
|---|
| 9 | 8 | S/laying of 25sqmm G.I. strip 5mm thick 0.5 mtr G.I as conductor earth electrode including thimble etc. | BI01010001010000000000000515BI0100001120 | 670 | Mtr. |
|---|
| 10 | 9 | S/E of underground cable loose in existing pipe or trenches complete with necessary connections. make :- Havells, KEI, Polycab\n50sqmmx 4 core (unarmored) \n | BI01010001010000000000000515BI0100001122 | 120 | Mtr. |
|---|
| 11 | 9.1 | 25 sqmm x 4 core (armoured)\n\n\n | BI01010001010000000000000515BI0100001123 | 2200 | Mtr. |
|---|
| 12 | 10 | Supply & erection of Godrej type almirah type MS pedestal made of 50mmx50mmx6mm angle iron frame with 3mm thick MS sheet covering including shutters with suitable hinges and locking arrangements with Godrej type handle including round bars. The top covering should have down ward overhang of 75mm on all sides of pedestal having two sets of water proof ventilation holes of suitable size on the side at top and bottom each set containing four Nos. holes to discharge the heat produced by the current. The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof. The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embedded upto the entire depth in 1:2:4 cement concrete block projected 75mmm all around the pedestal and 200mm above ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. \nM.S. pedestal of size 750mm wide, 1200mm high, 300mm deep and bottom totally open duly embedded in cement concrete block of size 900mm x 450mm x 200 mm above ground level duly plastered with 12mm thick 1:4 cement plaster having a base of size 1050mmx 600mmx250mm below ground level.\n | | 6 | No |
|---|
| 13 | 11 | Supply & Erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work\n2.5 sqmm (Round thimble)\n | | 165 | No. |
|---|
| 14 | 11.1 | 25 sqmm (for 25sqmm x 4 core cable) | | 440 | No. |
|---|
| 15 | 11.2 | 50 sqmm (for 50 sqmm x 4 core cable) | | 48 | No. |
|---|
| 16 | 12 | Supply & Erection of mark double walled corrugated (DWC) HDPE pipe laid 1 mtr. below ground level including digging and refilling of earth including cost of suitable size socket/ coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer- in –charge of the work.\nMake : Rex/ Telerex/Duragaurd\nHDPE pipe 63/50mm outer dia/inner dia (used for 50sqmm cable)\n | | 1850 | Mtr. |
|---|
| 17 | 13 | Supply, installation, testing and commissioning of automatic On/Off system to On and Off the street light system automatically as per time schedule of the department having 1 Nos., 3 pole power contactor of rating 110amp, coil voltage 250 Volt AC, 50Hz Model No. MNX 110, category No. – CS94138, make L&T, One digital timer 250volt A.C. make GIC or indo Asian, one toggle switch 2 way type. All there items should be installed on a MS sheet of Size 0.6mtrx0.5 mtr,x 3mm thick and wiring with 10sqmm single core copper wire in PVC channel including all petty material like copper lugs, nuts and bolt complete in all respect upto the entire satisfaction of engineer-in-charge of work. | | 6 | No. |
|---|
| 18 | 14 | Trenchless, horizontal braring 100 mm dia including cost of HDPE pipe 63/50 laid 1 mtr. below ground level.\n\n\n | | 500 | Mtr. |
|---|
| 19 | 15 | S/E of hot dip galvanized single arm bracket (totally galvanized) with each arm of 50mm dia MS PIPE 1500MM long (3.25mm thick) duly welded with 450mm long 3mm thick octagonal canopy of suitable dia (3mm thick) with angle of inclination 105 degree of the vertical. The top end of the canopy should be closed with MS sheet of 16 SWG. The bracket and canopy be supported with a bracing pipe (GI) 1400mm long, 25mm dia MS pipe (2mm thick). The rates are inclusive of cutting, welding and all labour charges. The bracket shall be as per design and drawing enclosed complete in all respect.\nSingle Arm\n | | 40 | No |
|---|
| 20 | 16 | Supply & erection of LED Street light luminaries 25 watt with pressure die cast aluminum housing, with individual LED’s with modular secondary optics and IP65 protection complete in all respect up to the entire satisfaction of Engineer in Charge of the work. Make Bajaj model No. 169826 BRLEP 25 watt LED WH or equivalent model of Phillips, GE, LT (As per technical specification attached in annexure-II) | | 314 | No. |
|---|
| 21 | 17 | Supply and Erection of LED streetlight Luminaries 90 watt with pressure die case aluminium housing with individual LED’s with modular secondary optics and IP66 protection complete in all respect of Bajaj Model No. 169911 BRLEP 90 W LED V2, or Equivalent model of Philips, GE, LT with 120 lumens per watt. \n | | 125 | No |
|---|
| 22 | 18 | S/E of Metal clad bass bar chamber made 1.6 mm thick MS sheet & fixing with bolts on wall or in existing pedestal complete in all respect (Alum. Bars)\n100 amp 4 bars of 55 cm each (cross section 25 mm x 6mm) chamber overall size 60cm x 45 cm x 18 cm \n | | 6 | No |
|---|
| 23 | 19 | Supply & erection of molded case circuit breaker on wall or on existing pedestal including bonding to earth and necessary connection. \nMake: Siemens/Havells/L&T\n100 amp to 220 amp. 415V 35 KA 3 Phase\n | | 6 | Nos |
|---|
| 24 | 19.1 | S/E of sheet steel enclosure DB suitable for MCBs etc. on wall/existing pedestal\nDistribution board 2 way SPN\n | | 55 | No. |
|---|
| 25 | 19.2 | Distribution board 3 way SPN | | 6 | No. |
|---|
| 26 | 20 | Supply & erection of MS Nuts & Bolts OFF sizes as per IS 1363/1966 pitch screw threaded and latest amendment complete in all respect. | | 43 | Kg |
|---|
| 27 | 21 | Wrought iron and mild steel (using angles,flats,square bars tee and channels) ladders grills, grafting frames, window guards, iron doors openable or fixed stair case or parapet or any other type or railing, gates and tree guards etc. Including cost of crews and welding rods or bolts and nuts complete fixed in position. \n(i) Flats, tees, angles and channels.\n | | 24.89 | Qtl. |
|---|
| 28 | 22 | Supply, installation, Testing and commissioning of Flood Light 200 watt BVP410 of Phillips make/ BARFEG 200 watt Bajaj on 12.5 mtr./ 16 mtr./ 20 mtr. long High Mast, complete in all respect up to entire satisfaction of Engineer-in-charge of work.\n | | 15 | No. |
|---|
| 29 | 23 | Part - B, HT/LT Line \nSupply and erection of GI pipe for transformer earthing 40mm dia (B-class) with 12mm dia holes in 100 mm dia bore in earth upto moisture level using proper earth electrode upto full length suitable for pole mounting substation, earthing should be designed with regards to max likely earth fault current\n0-15 mtr. \n | | 288 | Mtr. |
|---|
| 30 | 24 | Extra for using slat and charcoal/ coke for pipe earth electrode as required. | | 20 | No. |
|---|
| 31 | 25 | S/laying of 25sqmm G.I. strip 5mm thick 0.5 mtr G.I as conductor earth electrode including thimble etc. | | 400 | Mtr. |
|---|
| 32 | 26 | S/E of PCC poles as per specification 1678/1960\n9 mtr long 105 mm x115 mm at top and 105 mm x 315 mm at bottom with working load of 200 kg buried 1.8 mtr in ground.\n | | 225 | No. |
|---|
| 33 | 26.1 | 11 mtr. Long PCC pole 152x203mm at top and 152mmx368mm at bottom with working load of 360kg. Buried 2.20 mtr. In ground. | | 31 | No. |
|---|
| 34 | 27 | Supply, stringing & sagging of ACSR conductor as per IS-398 (part-II):1976- Specification.\nACSR 50sqmm\n | | 10.92 | Km |
|---|
| 35 | 27.1 | ACSR 80 sqmm\n | | 43.68 | Km |
|---|
| 36 | 27.2 | ACSR 100 sqmm (Stringing and sagging Labour rate only) | | 2 | Km |
|---|
| 37 | 28 | Supply & erection of MS Nuts & Bolts OFF sizes as per IS 1363/1966 pitch screw threaded and latest amendment complete in all respect.(893+100) | | 993 | Kg |
|---|
| 38 | 29 | Wrought iron and mild steel (using angles,flats,square bars tee and channels) ladders grills, grafting frames, window guards, iron doors openable or fixed stair case or parapet or any other type or railing, gates and tree guards etc. Including cost of crews and welding rods or bolts and nuts complete fixed in position. \n(i) Flats, tees, angles and channels.(15+8.00+24.89)\n | | 23 | Qtl. |
|---|
| 39 | 30 | Supply & Erection of 11 KV Pin Insulator B type with pin, brown glazed, 5KN, as per IS:731(1971) dry power frequency 1 min. With stand voltage 45 KV, wet power frequency with 1 min. Stand voltage 35 KV , nominal system voltage 11 KV Is system voltage 12 KV complete in all respect. | | 93 | No. |
|---|
| 40 | 31 | Supply, installation, testing, commissioning and handing over 25 KVA transformers, voltage ratio 11KV/433V, 3 Phase, 4 wire 50 Hz. Alum wound oil immersed natural cooled type (ONAN). The transformer shall be a single tank type with termination on bushing or (outdoor type) complete in all respect as per IS 2026-1977 upto entire satisfaction of engineer in-charge of works. | | 4 | No. |
|---|
| 41 | 32 | Supply & Erection of 11 KV G.O switch complete with 6 nos. Heavy duty post insulators & heavy duty brass male & females, B-Class pipe for operating, handle excluding M.S clamp complete in all respect with necessary lubricants. | | 4 | No. |
|---|
| 42 | 33 | Supply & Erection of lightening Arrestor 11 KV 5 KA as per IS-3070 (Part-III) & IEC 60099-4(2009) complete in all respect as per entire satisfaction of Engineer-in-charge. | | 4 | Set |
|---|
| 43 | 34 | Supply and erection of 11 KV disc insulator 4500 Kg ball and socket or T&C type complete suitable for 11 KV systems Porcelain/ silicon type as per the specification and approved make of DHBVN. | | 36 | No. |
|---|
| 44 | 35 | Supply & Erection of 300 mm2 single core aluminium conductor PVC insulated cable as per ISSS-154/P-I complete in all respect upto the entire satisfaction of Engineer-in-Charge. | | 200 | Mtr. |
|---|
| 45 | 36 | Supply & Erection LT fuse unit having 6 nos. Bus bar strips L type suitable for 200 Amp. & 6 nos. Porcelain bases on wooden or backlit sheet minimum 25 mm thickness complete in all respect. Including all content | | 4 | No. |
|---|
| 46 | 37 | Supply & Erection of MSD strap made cut of 50x6 mm M.S flat having suitable holes and accessories to fit it properly as per HSVP drawing/specification upto the Entire satisfaction of engine-Charge. | | 1200 | No. |
|---|
| 47 | 38 | Supply & erection of GSL wire 8 SWG complete in all respect as per ISS 280/1978 and IS 786/1963 with latest amendment (1213 +140) | | 1353 | Kg |
|---|
| 48 | 39 | Supply & Erection of shackle insulator as per state electricity specification upto the Entire satisfaction of engine-Charge.\n | | 1500 | No. |
|---|
| 49 | 40 | Supply & Erection of LT/HT guard made from G.I wire 8 SWG including cost of 01 no. porcelain guard real insulator required size to be provided between neutral wire and earth wire as design drawing of HSVP /DHBVNL specification complete in all respect upto the Entire satisfaction of engine-Charge.\n | | 1395 | No. |
|---|
| 50 | 41 | Supply & Erection of LT PVC phase separator 4 way suitable for LT line, 415 Volts 3 phase system at existing LT line on 9 mtr. Long PCC poles complete in all respect as per entire satisfaction of Engineer-in-charge.\n | | 1325 | No. |
|---|
| 51 | 42 | Supply & Erection of L.T stay set suitable for 9 mtr. Long PCC pole complete with hot dip galvanized stay rod & elbow, angel, channel & flat, egg insulator nut & bolts in all respect as per entire satisfaction of Engineer-in-charge. | | 138 | No. |
|---|
| 52 | 43 | Supply and erection of MS Rod earthing set (HT/LT) 20 mm dia 2.5 mtr. Long MS rod, 6 SWG thick conduct pipe 25 mm dia and 3 mtr. Long enamelled black paint and 6 SWG GI wire complete in all respect upto entire satisfaction of engineer in-charge of work. | | 89 | No. |
|---|
| 53 | 44 | Supply & Erection of HT stay set suitable for 11 mtr. Long PCC pole complete with hot dipped galvanized stay rod & elbow, angel, channel & flat, disc insulator nut & bolts in all respect as per entire satisfaction of Engineer-in-charge\n | | 16 | No. |
|---|
| 54 | 45 | Deduction of old/damaged T-5 28/40 Watt fitting on 9/11 mtr. Long STP/PCC pole as available at site including cost of dismantlement complete in all respect | | 150 | No. |
|---|
| 55 | 46 | Deduction of old/damaged 150 Watt Sodium fitting on 9/11 mtr. Long STP/PCC pole as available at site including cost of dismantlement complete in all respect | | 56 | No. |
|---|
| 56 | 47 | Deduction for old dismantlement ACSR conductor size 20/50 sqmm as available at site including cost of dismantlement complete in all respect\n | | 1400 | Kg |
|---|
| 57 | 48 | Deduction for old dismantlement old steel item such as channel, angel, flat & STP single bracket etc. as available at site including cost of dismantlement complete in all respect\n | | 2800 | Kg. |
|---|