| Name of Work: \"Construction of Circuit House of Bhergaon Civil Sub-Division at Bhergaon, Udalguri, BTAD (Assam).\" | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Building Civil Works\n1.1. Earthwork in excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soil including bailing out water where necessary as directed and specified. (A) Upto a depth of 2.00m below the existing ground level. (a) In ordinary soil. | BI01010001010000000000000515BI0100001113 | 371 | Cum |
| 2 | 2 | 1.3. Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(C ) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | BI01010001010000000000000515BI0100001114 | 333 | Cum |
| 3 | 3 | 2.1 PLAIN CEMENT CONCRETE WORKS\n2.1.1. Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls brick works etc. as directed and specified including dewatering if necessary and curing complete. (a) In prop. 1 cement : 3 sand : 6 coarse aggregate by volume | BI01010001010000000000000515BI0100001115 | 22.5 | Cum |
| 4 | 4 | 2.1.2. Plain cement concrete floor base in prop. 1:3:6 laid in alternate bays as specified with coarse agg. Of size 13mm to 32mm including dewatering if necessary and curing etc. Complete \n(c ) 100mm thick | BI01010001010000000000000515BI0100001116 | 554 | Sqm |
| 5 | 5 | 2.1.3. Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc. complete as directed. | 45 | Sqm | |
| 6 | 6 | 2.2. REINFORCED CEMENT CONCRETE WORKS\n2..2.1. Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine\n(A) In substructure up to plinth level \nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser. (b) M20 grade concrete or Prop. 1:1.5:3 | 192 | Cum | |
| 7 | 7 | (B) In super structure from plinth level up to 1st floor.\n(i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. (N) without using admixture, plasticiser (b) M20 grade concrete or Prop. 1:1.5:3 | 20 | Cum | |
| 8 | 8 | (ii) Columns, pillaes, posts struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing) including srepaing the top surface and finishing of nosing. \n(N) Without using admixture, plasticiser. (b) M20 grade concrete or prop. 1.1.5:3 | 200 | Cum | |
| 9 | 9 | 2.2.3. Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level. | 97 | Cum | |
| 10 | 10 | 3.1. TIMBER SHUTTERING (FORMWORK)\n3.1.1. Providing form work of ordinary timber planking so as to give a rough finish includingcentering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.00m and removal of the same for in - situ reinforced concrete and plain concrete work in:-\n3.1.1.1. Foundation, footings, bases of columns pile cap, raft and mass concrete work. etc.\n(b) Using 25mm thick plank | 320 | Sqm | |
| 11 | 11 | 3.1.1.2. Sides of tie beams, grade beams etc. at or below ground level.\n(b) Using 25mm thick plank | 237 | Sqm | |
| 12 | 12 | 3.1.1.3. Columns, Pillars, Posts & Strut\n(b) Circular or curved in plan (Using 38mm thick plank) | 15 | Sqm | |
| 13 | 13 | 3.2. PLYBOARD SHUTTERING (FORMWORK)\n3.2.1. Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.00m and removal of the same for in situ reinforced concrete and plain concrete work in \n3.2.1.1. Columns, Pillars, Posts & Strut of Squars/rectangular/polygonal in plan or any shape like Tee/L etc. having plane vertical face | 467 | Sqm | |
| 14 | 14 | 3.2.1.2. Side and Soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.\n(a) For depth not exceeding 1.0M | 855 | Sqm | |
| 15 | 15 | 3.2.1.3. Falt Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like, (a) Floors tec. Upto 200mm in thickness. | 906 | Sqm | |
| 16 | 16 | 3.2.1.6. Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like. | 350 | Sqm | |
| 17 | 17 | 3.2.1.8. Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. | 44 | Sqm | |
| 18 | 18 | 3.2.4. Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item No. 3.2.1. & 3.2.3 (b) | 1022 | Sqm | |
| 19 | 19 | MASONARY WORKS\n4.1.1. Providing soling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if nesessary dewatering, complete. (a) Brick on flat soling. | 769 | Sqm | |
| 20 | 20 | 4.1.4. Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In sub-structure upto plinth level including dewatering if necessary. (d) In proportion 1:6 | 57 | Cum | |
| 21 | 21 | 4.1.8. 1st class brick wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level. (A) 112mm thick brick wall (a) In cement mortar in proportion 1.4 (1 cement : 4 sand) | 1375 | Sqm | |
| 22 | 22 | 4.1.14. Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/R.B wall | 719 | Sqm | |
| 23 | 23 | FLOORING & FLOOR FINISHED\n5.7. TILES WORK 5.7.1. CERAMIC TILES (B) On Walls\n5.7.1.2. Providing polished ceramic wall tiles of approved quality, size, shape and thickess not less than 8mm on walls and stirtings over cement mortar bed 10mm thick in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). (a) Normal range Somany/Orient/Nitco/Asian Make\n(ii) Of size 200mm X 300mm and above | 251 | Sqm | |
| 24 | 24 | 5.7.2. VITRIFIED TILES (A) ON FLOOR\n5.7.2.1. Providing VITRIFIED floor files of approved quality of specified size, shape and thickness not less than 18mm on floor, skirting, risers and treads of steps over 15mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf/White cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (a) Normal range Somany/Orient/Nitco/Varmora/VITA/Marbito/Make (ii) Of size 600mm X 600mm and above. | 955 | Sqm | |
| 25 | 25 | 5.7.3. CONCRETE TILES (A) FLOOR TILES\n5.7.3.1. Providing polished SUNROCK-Hi CTS/MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10mm thick in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department. (b) MULTIWYN TILES\nLegato, Ribbera, Matrix, Esquire, Enigma, Flora, Little Flora, Nirvana, Purl, Contoura, Cobble, Canaletta Nexus, Koral | 22 | Sqm | |
| 26 | 26 | 5.9. MARBLE FLOORING\n5.9.1. 18mm thick Marble stone slab flooring of sizes 1200 X 1200 including treads and risers of steps, skirting, laid over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (iii) Kumari Slab | 53 | Sqm | |
| 27 | 27 | 5.11. ANTISKID TILES\n5.11.1. Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 ( 1 cement : 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) white cement complete at all level as specified and directed. (A) CERAMIC (ii) Executive range- 1 (Sizes 400mm X 400mm and above)\n(a) Somany made - VC Shield (Group- 25) (406 X 406)mm Deluxe - VC | 71 | Sqm | |
| 28 | 28 | PLASTERING\n6.2. CEMENT PLASTERING\n6.2.1. 10mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4 | 3328 | Sqm | |
| 29 | 29 | 6.2.2. 15mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (A) On rough side. (b) In cement mortar 1:4 | 1316 | Sqm | |
| 30 | 30 | 6.2.5. Extra over irem No. 6.2.1. to 6.2.2. for plastering on celling and soffits of stairs up to 1st floor level ( instead of plastering on walls) including curing complete as directed. | 906 | Sqm | |
| 31 | 31 | 6.2.7. Extra over item No. 6.2.1. to 6.2.2. for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. (a) On Single coat plaster | 1843 | Sqm | |
| 32 | 32 | 6.2.8. Extra over item No. 6.2.1. to 6.2.3. for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed.\n(a) On single coat plaster | 1229 | Sqm | |
| 33 | 33 | 7. CEILLING, LINING AND PARTITION\n7.10. Ceiling with Exposed Metal (G.I.) Frame work with E-Gride-2430\n7.10.1. Providing and fitting, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm X 600mm / 1200mm X 600mm with main runner 38 X 24mm, cross tee 29mm X 24mm & wall angle 24mm X 24mm using 4mm/6mm thick High Pressure steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duty suspendedwith 4mm/6mm dia G.I./M.S. bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detector etc. The main runners to be secured to structure soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm X 600mm/1200mm X 600mm grid, all complete as per the drawing & directions of engineer-in-charge.\nFinally, if specified, boarder are to be painted with 2 coats of acrylic emulsion paint of approved shade/make over a coat of cement primer before installing it on the grid.\n(A) Standard Ceiling of Everest make or equivalent as directed by the department. \n(ii) Using 6mm thick FC Board. | 440 | Sqm | |
| 34 | 34 | 8.1. ROOFING\n8.1.33. Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately) TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department. (ii) 0.45mm thick | 520 | Sqm | |
| 35 | 35 | 8.1.34. Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges/Valley/Gutter/Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete.\nTATA Blue scope/Dyna roof/Durakokor/Wonder Roof or equivalent as directed by the Department.\n(ii) 0.45 mm thick | 165 | Rm | |
| 36 | 36 | 9. WOOD WORK\n9.1.2. Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with CC or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mm X 3mm X 250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coat of Kiricide oiling to the timber faces in concrete with CC and masonry as directed and specified. (b) With 1st class timber (Bonsum/Sundi) | 2.3 | Cum | |
| 37 | 37 | 9.9. DOORS/WINDOWS/VENTILATORS/CLERESTORY WINDOWS\n9.9.2. Providing, fitting and fixing full panelled doors/windows including oxidised M.S. butt hinges (100mm X 75mm X 3.55mm) with necessary screws (other fittings to be meadured and paid separately)\n(b) With 1st class local wood ( Gamari/Hollock/Bonsum) 35mm thick | 51.5 | Sqm | |
| 38 | 38 | 9.18.1. Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm cross battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hard wood timber of width not less than 50mm, fixed to the door frames (Chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.) (b) 35MM THICK | 72.5 | Sqm | |
| 39 | 39 | 10. GRILLS\n10.2. Providing, fitting and fixing M.S. grill of required pattern for windows/clerestory windows/openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I. Plain grill (c) Fixed to Brickwork/PCC/RCC | 2261 | Kg | |
| 40 | 40 | 11. ALUMINIUM WINDOWS AND VENTILATOR\n11.1.1. Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm X 3.15mm lugs 100mm long embedded in CC blocks 150mm X 100mm X 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately)\n(a) Side hung and Top hung windows and ventilators (ii) 5mm frosted glass | 9 | Sqm | |
| 41 | 41 | (b) Fixed windows and ventilators (ii) 5mm frosted glass | 6.5 | Sqm | |
| 42 | 42 | (iii) 6mm coloured glass | 5.5 | Sqm | |
| 43 | 43 | 11.1.2. Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a) 2 Track sliding window (i)6mm clear glass | 31 | Sqm | |
| 44 | 44 | (b) 3 Track sliding window (i) 6mm clear glass | 159 | Sqm | |
| 45 | 45 | DSR-16 PVC FOAM SHEET\n9.125. Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (Bathroom and W.C. doors) using synthetic rubber based adhesive. | 17.5 | Sqm | |
| 46 | 46 | 13. PAINTING\n13.4.7. Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a). Acrylic Emulsion Paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) | 2492 | Sqm | |
| 47 | 47 | 13.3. PLASTER OF PARIS & WALL PUTTY\n13.3.5. Providing two coats of J.K. wall Putty (White Cement based putty for concrete/mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) | 4335 | Sqm | |
| 48 | 48 | EXTERIOR PAINTS/COATINGS\n13.5.2. Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade by thinning by adding water as per the specification of manufacturer after throughly brooming the surface to remove all dirt and remains of loose powdered materials as specified and directed by the department. (a) Unicem Shakti. | 1843 | Sqm | |
| 49 | 49 | 13.6. PAINTING ON WOOD AND WOOD BASED SURFACES\n13.6.3. Applying priming coat over new wood and wood based surface over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (b) With ready mixed paint, wood primer (White) | 308 | Sqm | |
| 50 | 50 | 13.6.5. Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.\n(i) Surfaces over 100mm in width or girth.\n(a) General purpose (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) | 308 | Sqm | |
| 51 | 51 | 13.7. PAINTING ON STEEL AND OTHER METAL SURFACE\n13.7.2. Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil grease, dirt and other foreign matter and scoured with wire brushed, fine steels, wood scrapers and sand paper. (a) With ready mixed \"red-lead/red oxide\" primer. | 291 | Sqm | |
| 52 | 52 | 13.7.4. Painting two coats (excluding priming coat ) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J&N paint/Nerolac ) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i) Surfaces over 100mm in width or girth. (a) General purpose (Asian paint/Berger paint/ICI paint/J&N paint/ Nerolac). | 291 | Sqm | |
| 53 | 53 | 15. DOOR AND WINDOW FITTINGS\n15.2. ALUMINIUM FITTINGS\n15.2.1. Supplying, fitting, fixing anodised aluminium fitting of approved make, resonably smooth, free from sharp edges and corners, flows and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished) (a) Sliding door bolts (ii) 250mm X 16mm | 62 | Each | |
| 54 | 54 | (b) Tower bolts (iii) 200mm X 12mm | 84 | Each | |
| 55 | 55 | (c ) Door handles (ii) 100mm | 84 | Each | |
| 56 | 56 | 18. STEEL AND IRON WORK \n18.1. REINFORCEMENT \n18.1.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are including in the rate) (Upto 1st floor level) (a) From Primary Produce : TATA/SAIL/Esser Steel/Jindal steel/Shyam steel/RINL.\n(ii) Super Ductile (SD) TMT reinforcement bars | 486 | Qtl. | |
| 57 | 57 | 18.1.2. Extra over item 18.1.1. (a,b,c) for each subsequent floor or part thereof above first floor level. | 114 | Qtl. | |
| 58 | 58 | 18.3. ROOF TRUSS\n18.3.1. Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevent I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawings as directed . (b) Using other ISI marked approved circular hollow section. | 66 | Qtl. | |
| 59 | 59 | 19. PLINTH PROTECTION WORKS\n19.3. Providing plinth protection with brick laid on edge and grouted with cement mortar 1:4 and finishing with cement pointing in prop. 1:1 complete. | 171 | Sqm | |
| 60 | 60 | 19.4. Providing drain with cement concrete (1:3:6) 10cm thick sides 10 cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.\n(ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. | 190 | Rm | |
| 61 | 61 | M.S. RAILING\nProviding fitting, fixing M.S. Railing of height 900mm on staircase, balcony with M.S. Tube, Bar etc including all necessary fitting & fixures as directed by the engineer in charge. | 92 | Rm | |
| 62 | 62 | 21. PILING WORKS\n21.1.1. Providing cast in-situ manually driven reinforced cement concrete piles of using required grade of cement concrete of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings Reinforcement to be measured and paid seperately as per item No. 21.4.1. (C) UNIFORM PILE (d) Pile Dia 400mm (i) Upto 10M | 1881 | Rm | |
| 63 | 63 | 21.4.3. Empty boring for specified diameter piles from ground level to cut-off level. (d) Pile Dia 400mm | 167 | Rm | |
| 64 | 64 | 21.5. REINFORCEMENT\n21.5.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc)\n(B) TMT bar of other ISI marked (From Secondary producer) | 188 | Qtl. | |
| 65 | 65 | 12.6. LOAD TEST ON PILES\nROUTINE TESTS\n21.6.1. Routine test for test loading to 1.5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. | 90 | Ton | |
| 66 | 66 | 21.6.2. Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. | 60 | Ton | |
| 67 | 67 | 22. WATERPROOFING\n22.1. SURFACE PREPRATION\n22.1.1. Preparing the RCC surface in roof slab, chajjas, terraces sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particies like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels. | 40 | Sqm | |
| 68 | 68 | 22.3. Water Proofing of Chajjas, roof slabs, terraces, sunken slabs, septic tank Oh tank, raft slab in basement, walls etc.\n22.3.5. Providing and laying modified bituminous water proofing membrane system in roof, Polymod-AP of choksey Chemicals, 3mm thick APP modified weaterproofing membrane by torch on method using LPG torch flame after applying a coat of Bituminous primer \"Primer Polymod-SB\" @ 0.2 Kg/Sqm complete as specified and directed by the Department followed By-\nSupplying, providing, mixing and laying of concrete screed of average 75mm thick in proportion 1:2:4 (1 cement : 2 fine aggregate : 4 coarse aggregate) (by volume) with 12mm and down well graded aggregates and admixed with a normal plasticizer like Master Plast PL- 1 of Choksey Chemicals/Dr. Sealkit Normal Plast (Asian Chemicals) @ 0.3 % by weight of cement after making the concrete fibre reinforced for reducing the effect of thermal expansion by mixing concrete with Recron 3s @ 1.25 kg per bag of cement and / as specified and directed by the Department. | 40 | Sqm | |
| 69 | 69 | 26.1 PRE CONSTRUCTION ANTI- TERMITE TREATMENT\n26.1.1. Pre construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from botton of the excavation made for column plinth beam, wall trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before staarting construction work (Supplying of necessary tools and accessorise by the contractor) a per the direction of the Department complete.\n(a) With aquous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | 770 | Sqm | |
| 70 | 70 | SANITARY AND WATER SUPPLY\n1.2. Providing fitting and fixing vitreous china pedestal type water closet (European type W.C. pan 40mm high) with seat and lead , CP brass hinges and rubber buffers, CI/MS brackets, 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) (A) Parryware make/a) White/(vii) Niagara (Cat No. C0252) (inclusive of seat cover). | 10 | Each | |
| 71 | 71 | PVC FLUSHING CISTERN\n1.5. Supplying, fitting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. complete as directed and specified (pipes will be measured separately)\n(i) Parryware make/a) White/(i) Economy single Flush (Cat No. C8090/C8055) | 10 | Each | |
| 72 | 72 | WASH BASIN\n1.13. Providing vitreous China wash basin with CI/MS brackets, C.P. brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, Stop cocks, waste coupling are to be paid separately)\n1.13.2. Basin (without pedestal) (A) Parryware Make (i) White (i) Star Basin 550 X 400 (Cat. No. C0450) | 10 | Each | |
| 73 | 73 | Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings, cutting & making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately.\n(A) Parryware Make (ii) Single Bowl with Drain Board (400 X 200) Flat Edge-Glossy (Cat No. C8537) | 6 | Each | |
| 74 | 74 | MIRROR \n1.19. Providing fitting and fixing Decorative Mirror complete as directed and specified.\n(A) Parryware Make (b) Size 600mm X 450mm | 10 | Each | |
| 75 | 75 | SHELF\n1.2. Providing fitting and fixing Glass Shelf complete as directed and specified.\n1.20.1. Glass shelf with CP guard rail (ii) Sona make (Cat No. TR-0701) (a) 450mm | 10 | Each | |
| 76 | 76 | SOAP TRAY, SOAP DISH, LIQUID SOAP\n1.21. Providing, fitting and fixing recessed soap tray/soap dish complete as directed and specified. \n(A) Parryware Make (ii) Wall Soap tray (Cat. No. C9951) | 10 | Each | |
| 77 | 77 | TOILET PAPER HOLDER\n1.31. Providing, fitting and fixing Chromed Plated TOILET PAPER holder complete as directed and specified.\n(a) Jaquar make/(i) Continental toilet paper holder (Cat No. ACN-1151N) | 10 | Each | |
| 78 | 78 | TOWEL RAIL, TOWEL RACK & TOWEL RING\n1.24. Providing, fitting and fixing CP towel rail complete as directed and specified. \n(a) Jaquar make (iv) Queen's (450mm long) (Cat No. AQN-7711A) | 10 | Each | |
| 79 | 79 | WASTE COUPLING\n1.32. Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar Make (i) 32mm (HT/FT) (Cat. No. ALD-705/709) | 16 | Each | |
| 80 | 80 | BOTTLE TRAP\n1.33. Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. \n(b) Sona make (i) Bottle trap indian 32mm (Cat No. BT-0751) | 16 | Each | |
| 81 | 81 | 1.37. PVC PIPES, BENDS, JUNCTIONS, TEES ETC. \n1.37.1. Supplying, fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trenches. (ii) 110 mm dia. | 153 | Rm | |
| 82 | 82 | (iv) 75mm dia. | 40 | Rm | |
| 83 | 83 | (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. \n(ii) 110 mm dia. | 114 | Rm | |
| 84 | 84 | (iv) 75mm dia. | 10 | Rm | |
| 85 | 85 | 1.37.2. Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\n(a) In exposed surfaces or in trenches. (ii) 110mm dia | 18 | Each | |
| 86 | 86 | (iv) 75mm dia. | 3 | Each | |
| 87 | 87 | (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. (ii) 110mm dia. | 20 | Each | |
| 88 | 88 | (iv) 75mm dia. | 8 | Each | |
| 89 | 89 | 1.37.4. Supplying, fitting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (ii) 110mm dia | 12 | Each | |
| 90 | 90 | (iv) 75mm dia. | 4 | Each | |
| 91 | 91 | COWEL\n1.39. Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. \n(ii) 110mm dia. PVC cowel of ISI make | 5 | Each | |
| 92 | 92 | GRATING\n1.40. Providing fiting & fixing CI Grating to the floors complete as directed and specified.\n(a) 110mm dia. | 12 | Each | |
| 93 | 93 | MANHOLE COVER\n1.49. Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 19kg. Weight complete as directed and specified. | 4 | Each | |
| 94 | 94 | SOAK PIT AND INSPECTION CHAMBER\n1.51. Construction of filter bed in soak pit including earth work in excavation of soil and then filling up to the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table. | 35 | Cum | |
| 95 | 95 | 1.52. Construction of inspection pit inside measurement 450mm X 450mm X 450mm flush with 100mm diameter HCl/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm X 450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. | 4 | Each | |
| 96 | 96 | 3.1. PIPING\n3.1.6. Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe.\n(A) Exposed or in trenches (b) 20mm nominal outer dia pipe. | 35 | Rm | |
| 97 | 97 | e) 40mm nominal outer dia pipe. | 45 | Rm | |
| 98 | 98 | f) 50mm nominal outer dia pipe | 20 | Rm | |
| 99 | 99 | (B) Concealed pipe with cutting chases & making good the walls.\nA) 15mm nominal outer dia pipe | 10 | Rm | |
| 100 | 100 | b) 20mm nominal outler dia pipe. | 80 | Rm | |
| 101 | 101 | d) 32mm nominal outer dia pipe. | 35 | Rm | |
| 102 | 102 | 3.2. BIB COCK\n3.2.1. Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand dircted and specified.\n(G.I. & C.P. pipes will be measured separately) (ii) Jaquare make (i) Standard | 21 | Each | |
| 103 | 103 | 3.3. STOP COCK\n3.3.1. Supplying fitting and fixing stop-cock of approved brand of size as measured below and directed and specified (G.I. & C.P. pipes will be measured and paid separately)\n(i) Brass stop cock (heavy) of Sant make (i) 15mm dia | 3 | Each | |
| 104 | 104 | (iv) 32mm dia | 2 | Each | |
| 105 | 105 | (v) 40mm dia | 2 | Each | |
| 106 | 106 | 3.5. PILLAR COCK \n3.5.1. Supplying and fitting fixing C.P. piller cock of 15mm dia of approved brand as specified and directed. (ii) Jaquare make (ii) Continental | 10 | Each | |
| 107 | 107 | 3.6. SINK COCK\n3.6.1. Supplying fitting and fixing chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately)\n(iii) Essco brand (b) Sink cock with Ü\" shape bend pipe. | 6 | Each | |
| 108 | 108 | 3.8. SHOWER\n3.8.1. Supplying fitting and fixing overhead adjustable chrome Plasted (C.P.) spray shower15mm dia.od sona make with wall flange as directed and specified. (Pipes will be measured and paid separately) (a) Supreme shower with arm. | 10 | Each | |
| 109 | 109 | 3.2. VALVE\n3.17.1. Supplying and fitting gun mental country pit valve (full way valve) ISI make as specified and dircted. (a) 50mm dia | 2 | Each | |
| 110 | 110 | (b) 40mm dia. | 2 | Each | |
| 111 | 111 | c) 25mm dia. | 2 | Each | |
| 112 | 112 | 6.1. WATER TANK\n5.4.2. Supplying and placing plaster cylindrical vertical claused top (PCVC) tank of sintex/Polycon/Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for intel and outlet pipes.\n(i) 2000 Lt. capacity water tank (b) Polycon Make | 4 | Each | |
| 113 | 113 | ELECTRICAL WORKS\n2.1. Wiring for light/fan/call bell point with 2 X 1.5 sq. mm PVC insulated singles core unsheathed industrial (Multistrand) cable FR conforming to IS-694 : 1990 with flexible bright annealed electrolytic copper conductor fo voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part-III conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) including 6 AMP flush type switch/bell push (Anchor penta/Gold medal/Kolor kany Kom/Havells or equivalent make as apprved by the Deptt. etc. complete. 2.1.1. (a) SP upto 3.00 metre length. | 110 | point | |
| 114 | 114 | 2.1.2. (b) MP upto6.00 metre length. | 240 | point | |
| 115 | 115 | 2.1.3. ( C) LP upto 10.00 metre length | 260 | point | |
| 116 | 116 | 2.2. Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel/Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed 2mm thick/heavy rigid ISI marked IS: 9537 PART- III rigid PVC conduit (Berlia/AKG/Precision/Presto Plast/ Polycab/MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta/Gold medel/Kolor kany. Kom/Hevells or equivalent make as approved by the Deptt.) GI/MS switch board (I.S.I mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm cable to third pin of the plug socket etc. as required complete, when placed elsewhere.\n2.2.1. Short point up to 3.00 metre. length | 16 | Each | |
| 117 | 117 | 2.2.2. Medium point up to 6.00 metre Length | 16 | Each | |
| 118 | 118 | 2.2.3. Long point up to 10.00 metre Length | 16 | Each | |
| 119 | 119 | 2.3. Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS- 694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel/ Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta/Gold medal/Kolor kany. Kom/Havells or equivalent make as approved by the Deptt. GI/MS switch board (ISI marks with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20mm. dia. 2mm thick/heavy ISI marked IS: 9537 PART-III rigid PVC conduit (Berlia/AKG/Precision/ Presto PLast/Polycab/MW or equivalent make as approved by the Deptt. )\n2.3.3. Long point up to 10.00 metre Length | 18 | Each | |
| 120 | 120 | 2.7. Wiring for drawings sub-main line with PVC insulated single core unsheathed industrial (Multistand) cable FR conforming to IS- 694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/recessed 20mm dia. 2mm thick/heavy ISI marked IS: 9537 PART-III rigid PVC conduit wiring system.\n2.7.1. With 2 X 2.5 sqmm + earth continuity with 1 X 2.5 sqmm PVC insulated unsheathed sign le core copper cable in 19mm dia rigid PVC conduit pipes. | 2200 | mtr | |
| 121 | 121 | 2.7.2. With 2 X 4 sqmm + earth continuity with 1 X 2.5 sqmm PVC insulated unsheathed sing le core copper conductor cable in 19mm dia. Rigid PVC conduit pipes. | 280 | mtr | |
| 122 | 122 | 2.7.3. With 2 X 6 sqmm + earth continuity with 1 X 4 sqmm PVC insulated unsheathed sign le core copper conductor cable in 19mm dia. Rigid PVC conduit pipes. | 560 | mtr | |
| 123 | 123 | 2.8. Wiring for drawings sub-main line with PVC insulated single code unsheathed industrial (Multistrand) cable FR conforming to IS0 694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) including earth continuity in surface/recessed PVC 20mm. dia 2mm thick/heavy ISI marked IS: 9537 PART-III rigid PVC conduit (Berlic/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt. wiring system.\n2.8.4. With 3 X 10 sq. mm. + earth continuity with 2 X 6 sq mm, cable in 32 mm dia. 2 mm thick/heavy rigid PVC IS : 9537 Part-III conduit. | 160 | mtr | |
| 124 | 124 | 2.10. Wiring for 5 pin 6 amp plug with 1.5 sq mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel/Nicco/Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta/Gold medal/Kolor kany. Kom/Havelly or equivalent make as approved by the Deptt. make and 6 amp flush type switch (Anchor penta/ Gold medal/Kolor kany. Kom/Havells or equivalent make as approved by the Deptt. make earthig the 3rd pin of the socket as required on the switch board in surface/recessed PVC conduit wiring system. When fitting on same board of light and fan. | 216 | Each | |
| 125 | 125 | 11.12. Supplying and fixing of polished Brass Bracket of 18 SWG 25cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt. As required without Lamp | 240 | Each | |
| 126 | 126 | 11.22. Supplying and fixing of 250/305 mm dia (Nominal size flush type circular ceiling fittings complete with holder, Aluminium anodized back plate and brass holder, 20 watt CFL lamp including connection as approved by the Deptt. As required | 40 | Each | |
| 127 | 127 | 11.32. Supplying and fixing of call bell (Buzzer) including 5/6 amp capacity button paino type bell push switch including connection as approved by the Deptt. As required. | 10 | Each | |
| 128 | 128 | 22.7. Installation of earth station with 40mm dia and 4.5 mtr. Long GI pipe with necessary GI reducing socket 40mm X 20 mm size locking arrangement with hinged cover plate, funnel GI nuts, thorough bolts etc. for putting pipe and refitting with necessary enclosure on the top etc. as required complete. | 30 | Each | |
| 129 | 129 | 22.12. Extra for using salt 5 kg and charcoal 64 Kg. for pipe earth electrode as required. | 30 | Each | |
| 130 | 130 | 22.15. Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. Below ground level or conductor earth electrode including soldering, excavation work and refitting etc as required complete. | 1642 | mtr | |
| 131 | 131 | ECBC1. Supplying including fitting fixing of following star rate A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt. Etc. as required complete and as directed by the Department (Without regulator). (ORIENT PSPO make/Usha make/CROMPTON/Havells/ ATC or equivalent make.\nECBC1.1.1. Energy efficient 5-star 1200mm sweep. ORIENT PSPO/Usha/CROMPTON/Havells/ACT or equivalent make. | 26 | Each | |
| 132 | 132 | 27.2. Supplying including fitting fixing of following AC Exhaust fan in the existing hole on the wall of followings sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department.\n27.2.1.2. Power Flow 225 mm sweep (ORIENT make) | 16 | Each | |
| 133 | 133 | 15.2. Supplying with fitting and fixing sheet steel, shosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grouting nuts & bolts as reqd. complete with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.\n15.2.1. ABB, Schneider MG, legrand, Hager make). \n15.2.1.4. 12 way SPN double door | 16 | Each | |
| 134 | 134 | 16.1. Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved , specified and directed by the deptt.\n16.1.2. C Series (Schneider MG, legrand, Hager make) 16.1.2.1. 6- 32A | 1606 | Each | |
| 135 | 135 | 16.7. Supplying with fitting and fixing 30/100/300 mA sensitivity 240/415 V 50 Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n16.7.1. 30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make)\n16.7.1.2. 40 A | 27 | Each | |
| 136 | 136 | Providing metering and service connection. | 14 | Each | |
| 137 | 137 | FIRE FIGHTING WORKS\n29.2. FIRE EXTINGUISHER\n29.2.3. Supply, Installation, fitting of DRY CHEMICAL POWDER File Extinguisher confirming to IS: 2171 with ISI Make, and CO2 Cylinder will be confirming to IS: 4947 with ISI make, Powder will be confirming to IS : 2878 with ISI Make (Extinguisher will be TROLLEY MOUNTED) (25 KG) BRAND : FIRESTOP/FIREND/ FIRE SHIELD | 2 | Each | |
| 138 | 138 | 29.2.7. bSupply, installation, Fixing of MECHANICAL FOAM (AFFF) Fire Extinguisher confirming to IS: 10204 with ISI Make and CO2 Cartridge will be confirming to IS: 4947 with ISI Make and CO2 cartridge will be confirming to IS: 4989 with ISI Mark. (50 LITERS) BRAND : FIRESTOP/ FIREND/ FIRE SHIELD | 2 | Each | |
| 139 | 139 | 29.2.11. Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguished confirming to ISI Make. (Extinguished will be TROLLEY MOUNTED) (9 KG) BRAND : FIRESTOP/FIREND/FIRE SHIELD | 4 | Each | |
| 140 | 140 | SEPTIC TANK (2 NOS)\n1.1. EARTHWORK IN EXCAVATION\nEarthwork in excavation for foundation trenches of Walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the followings classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil. | 21 | Cum | |
| 141 | 141 | 2.1. PLAIN CEMENT CONCRETE WORKS\n2.1.1. Plain cement concrete works with coarse aggregate of size 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid spparately)\n(a) In prop. 1 cement : 3 sand : 6 coarse aggregate by volumn | 1.3 | Cum | |
| 142 | 142 | 2.2. REINFORCED CEMENT CONCRETE WORKS\n2..2.1. Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (from work and reinforcement will be measured and paid separately)\n(I) Using Mixer Machine. (A) In substructure up to plinth level.\nFoundation, footing columns with base tie and plinth beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.(N) Without using admixture, plasticiser (a) M 15 grade concrete or Prop. 1:2:4 | 0.5 | Cum | |
| 143 | 143 | (b) M 20 grade concrete or Prop. 1:1.5:3 | 1 | Cum | |
| 144 | 144 | 3.1. TIMBER SHUTTERING (FORMWORK)\n3.1.1. Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of proping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\n3.1.1.1. Foundation, footings, bases of columns, pile cap, raft and mass concrete work etc.\n(b) Using 25mm thick plank.\n | 2.8 | Sqm | |
| 145 | 145 | 3.2. PLYBOARD SHUTTERING (FORMWORK)\n3.2.1. Providing form work of 12mm thick plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceilling not exceeding 4.0M and removal of the same for in situ reinforced concrete and pain concrete work in:\n3.2.1.2. Sides and soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0 M | 0.8 | Sqm | |
| 146 | 146 | 3.2.1.3. Flat surface such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.\n(a) Floors etc. upto 200mm in thickness. | 5 | Sqm | |
| 147 | 147 | 3.2.1.6. Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like. | 1.8 | Sqm | |
| 148 | 148 | 4.0 MASONRY WORK\n4.1.1. Providing soling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a) Brick on flat soling | 10 | Sqm | |
| 149 | 149 | 4.1.4. Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In sub-structure upto plinth level including dewatering if necessary. (d) In proportion 1:6 | 7 | Cum | |
| 150 | 150 | 6.2. CEMENT PLASTERING\n6.2.2. 15mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (B) On fair side.\n(b) In cement mortar 1:4 | 35.2 | Sqm | |
| 151 | 151 | DSR-16 13.18. Neat Cement Punning | 5 | Sqm | |
| 152 | 152 | DSR-16 19.18 MANHOLE COVER\nSupplying and fixing C.I. cover without frame for manholes:\n19.18.1. 455 X 610mm rectangular C.I. cover (Light duty), the weight of the cover to be not less than 23 Kg. | 4 | Each | |
| 153 | 153 | 18.1. REINFORCEMENT\n18.1.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for RCC work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)\n(b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg. drain works, retaining wall & boundary wall etc.) | 1 | Qtl. | |
| 154 | 154 | DEEP TUBE WELL & IRON REMOVAL WATER FILTER\n5.3.2. Labour for test boring with 40mm (internal) dia G.I. pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest PWD camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost). | 120 | Rm | |
| 155 | 155 | 5.3.4. Labour for boring hole for inserting tube well pipes through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out of the same and lowering pipes, fittings complete as directed by the Department.\n(vi) Bore hole of 200mm diameter | 120 | Rm | |
| 156 | 156 | 5.3.5. Supplying, fitting and fixing pipes plain/bevel ended for caing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying ans packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.\nII. PVC Pipe SUPREME/PRINCE/FUSION/SFMC Brand (Vii) 160mm diameter | 120 | Rm | |
| 157 | 157 | 5.3.6. Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. A. G.I. Pipes (a) TATA/SAIL (Medium) socket should be welded to the pipes. (iv) 50mm diameter | 90 | Rm | |
| 158 | 158 | 5.3.8. Supplying fitting and fixing brass Tez filter 2.00 metre long. | 9 | Each | |
| 159 | 159 | 5.3.11. Supplying fitting and fixing cheak valve (non return value) including thread to pipes.\n(iv) 50mm diameter | 3 | Each | |
| 160 | 160 | 5.3.12. Development of the tube well with copressor or by over pumping unit for 48 hours till sand free discharge is obtained. | 1 | Job | |
| 161 | 161 | 5.3.13. Flushing, clearing, washing and watering of the tube well. | 1 | Job | |
| 162 | 162 | IRON REMOVAL WATER FILTER\n6.3.2. Supplying fitting and fixing iron removal filter fitting with treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour of DOLPHIN make with all necessary fitting such as valve , bib cock, pipe connection etc. with a free maintance period of six months\n(A) With Zoloto fitting (i) 1000 liters capacity (a) 4mm thick vessel | 1 | Each | |
| 163 | 163 | MOTOR PUMP SET\n39.3.6. (APWD Electrial 2013-14). 5 HP single phase Centrifugal monoblock pump set (Crompton Greaves/Aquatic/CRI/V-Guard make) 2900 rpm with DOL Starter (Crompton Greaves/Control & Switch Gear / BCH/L&T/ Siemens make. | 1 | Each | |
| 164 | 164 | 39.7. Supplying including installation, connection as approved by the Deptt. Testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the Deptt.\n39.7.3. Three phase Submersible motor pump set (Texmo/Crompton Greaves/Aquatic/CRI/V-Guar suitable for 100mm bore well and above. 2 HP STAGE 6 to 30 with MCB controlled Submersible motor pump set control panel. | 1 | Each | |
| 165 | 165 | SITE DEVELOPMENT WORK\n1.4. Raising low site around the building with approved soil obtained form outsite by truck carrige including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation minicipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.\n(b) Other than Guwahati city | 852 | Cum | |
| 166 | 166 | 1.4. Extra lead per km truck carriage for sand gravel beyond the initial lead of 8 km. | 852 | Cum |