| 1 | 1 | (A) M/s Sant Kabir Service Station | b1 | | |
|---|
| 2 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth within and outside site to unobjectionable place, disposed earth to be levelled and neatly dressed. | b2 | | |
|---|
| 3 | 3 | i) All kinds of Soil | b3 | 32 | M3 |
|---|
| 4 | 4 | Extra for excavation for every additional lift of 1.5m or part thereof in ALL KIND OF SOIL | b4 | 9 | M3 |
|---|
| 5 | 5 | Supplying and Local sand filling within the grading zone V of fine aggregates specified in table 3.1 , clause 3.1.3 of attached specifications, in plinth, under floors etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming watering and dressing complete | b5 | 21 | M3 |
|---|
| 6 | 6 | Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering - All work up to plinth level : | b6 | | |
|---|
| 7 | 7 | iii)1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) | b7 | 1 | M3 |
|---|
| 8 | 8 | v)1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) | b8 | 1 | M3 |
|---|
| 9 | 9 | viii)1:4:8(1 Cement :4 Coarse Sand : 8 Graded stone aggregate of 40mm) | b9 | 2 | M3 |
|---|
| 10 | 10 | Centering and shuttering including strutting, propping etc. and removal of form work for PCC | b10 | | |
|---|
| 11 | 11 | i) C&S for PCC in foundations,footings,bases of column | b11 | 15 | M2 |
|---|
| 12 | 12 | Providing and laying in position specified grade of reinforced concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level | b12 | | |
|---|
| 13 | 13 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm | b13 | 13 | M3 |
|---|
| 14 | 14 | Centering and shuttering including strutting, propping etc. and removal of form for : | b14 | | |
|---|
| 15 | 15 | i) Foundations,footings,bases of columns, etc. for mass concrete | b15 | 100 | M2 |
|---|
| 16 | 16 | Supply of Reinforcement for R.C.C. including straightening, cutting, bending, placing in position & binding all complete at all levels | b16 | | |
|---|
| 17 | 17 | ii)Thermo Mechanically Treated Bars Fe- 500 grade,Conforming to IS1786 | b17 | 1250 | KG |
|---|
| 18 | 18 | Providing and laying Brick work with bricks of class designation 75 Including Scaffolding : | b18 | | |
|---|
| 19 | 19 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH | b19 | 6 | M3 |
|---|
| 20 | 20 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters,sills,facias,Pump Island & similar locations of required size of shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement mixed with matching pigment,epoxy touch ups, including rubbing,curing moulding & polishing to edge to give high gloss finish etc. complete at all levels. | b20 | | |
|---|
| 21 | 21 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | b21 | 1000 | KG |
|---|
| 22 | 22 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: | b22 | 8180 | KG |
|---|
| 23 | 23 | Providing & fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.50mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, with 5-7 micron epoxy primer and polyester top coat of 15-18 micron on both sides,total coated thickness(TCT) of 0.58mm.Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. | b23 | | |
|---|
| 24 | 24 | ii) Plain Sheet for Ridges (500 - 600mm). | b24 | 18 | M2 |
|---|
| 25 | 25 | iii) 160 mm diameter PVC Rain water pipe | b25 | 24 | M |
|---|
| 26 | 26 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of cold rolled steel sheet conforming to IS 513, having minimum yield stress of 240mpa & minimum tensile stress of 300mpa.Base metal thickness 0.45mm for ceiling panels and 0.55mm for carriers. The sheet shall be hot dip metallic coated with Zinc coating ( galvanising) as per IS 277, coating mass of 120gsm on both sides, over which organic coating with Modified polyester paint on a continuous coil coating line. Top side of ceiling panels and carrier shall have 15 micron modified polyester paint over 5 micron epoxy primer and Bottom side with Alkyd back coat over 5 micron primer Total coated thickness for Panels to be 0.50mm and for carriers 0.60mm. The ceiling panels shall be clipped in to carriers, suspended from steel/trusses /other members with the help of suspension angle of 25x25x0.5mm by means of rigid suspension system meant for exterior. Longitudinal joints of two panels shall be but jointed with special type of panel splice to be fixed from inner side.Carrier shall be jointed with carrier splices maintaining a module of 150mm | b26 | 180 | M2 |
|---|
| 27 | 27 | ii) 12mm Cement plaster of mix1:6 (1 cement: 6 coarse sand) | b27 | 150 | M2 |
|---|
| 28 | 28 | Applying one coat of cement primer of approved brand and manufacture on wall surface : | b28 | 150 | M2 |
|---|
| 29 | 29 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more over an under coat of suitable shade with ordinary paint of approved brand and manufacture. | b29 | 300 | M2 |
|---|
| 30 | 30 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications of Engineer-in- charge | b30 | 65 | M3 |
|---|
| 31 | 31 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty | b31 | | |
|---|
| 32 | 32 | ii) 150 mm dia. R.C.C. pipe | b32 | 20 | M |
|---|
| 33 | 33 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate | b33 | 32 | EA |
|---|
| 34 | 34 | Providing & laying 80mm thick factory made Lacquered finish Grey/ Coloured Pre-cast cement concrete, interlocking paver block of M 40 grade made by block making machine with strong vibratory compaction & of approved size and design/ shape ,shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength than 40 N/Sq.mm as per IS15658 maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length & width and +/- 3mm on thickness. The job includes supplying & laying a layer of 50mm thick clean course sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand,compacting with machine vibrator to required line and level, etc. complete .(Payment for provision of edge restraints shall be made separately) | b34 | 1200 | M2 |
|---|
| 35 | 35 | Providing and fixing 700mm wide rain water gutter fabricated out of 1200mm wide Roll of 18 Gauge Aluminium sheets including MS clamp supports, fittings, fasteners etc. complete as per drawing . (NO joints shall be provided in the gutter and the same has to be fabricated from a continuous roll of Aluminium sheet) | b35 | 24 | M |
|---|
| 36 | 36 | Providing & fixing BARE Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.55 mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. | b36 | 180 | M2 |
|---|
| 37 | 37 | Supply and Laying 3 Core x 1.5 sq. mm. (copper)Armoured cable as as per specifications and direction of Engineer in charge | b37 | 150 | M |
|---|
| 38 | 38 | Supply and Laying 3 Core x 2.5 sq. mm Copper Cable FRLS as per specifications and direction of Engineer in charge | b38 | 195 | M |
|---|
| 39 | 39 | Supply and Laying 4 Core x 2.5 sq. mm Copper Cable FRLS as per specifications and direction of Engineer in charge | b39 | 50 | M |
|---|
| 40 | 40 | P/F Cable termination for 3 Core x 1.5 sq. mm. with FLP double compression glands, lugs etc. as per specifications and direction of Engineer-in charge. | b40 | 1 | EA |
|---|
| 41 | 41 | P/F Cable termination for 3 Core x 2.5 sq. mm with FLP double compression glands, lugs etc. as per specifications and direction of Engineer-in charge. | b41 | 6 | EA |
|---|
| 42 | 42 | Supply & Laying Earthing 25 x 3 mm GI strip as per specifications and direction of Engineer in Charge. | b42 | 150 | M |
|---|
| 43 | 43 | S/I of MCB distribution board /double door with 8 way (4+24) TPN, as per specifications and direction of Engineer in Charge | b43 | 1 | EA |
|---|
| 44 | 44 | S/F Miniature Circuit Breakers of approved make of ratings 6A to 32A DP MCB, as per specifications and direction of Engineer in Charge | b44 | 4 | EA |
|---|
| 45 | 45 | S/E of 5 Meter high galvanised Octagonal pole with top 60mm (A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) | b45 | 6 | EA |
|---|
| 46 | 46 | Supply & Fixing of 90 to 100W LED fixtures with fittings and accessories for yard lighting purposes. The LED (Light emitting diode) of 100W should be operating under voltage range of 140-277V with power factor more than 0.9CCT (Correlated colour temperature) shall be 5700 Kelvin (5665K +/- 335K), CRI (Colour rendering index) not less than 65 and LED efficacy of minimum 120 Lumens / watt. The fittings shall conform to IP65 protection class with under pressure die cast Aluminium housing with 4mm thick toughened glass. The luminaire system should have a minimum efficacy of 90 Lumens per watt. The driver shall be of constant current type with internal surge protection. Supply of complete fitting with all accessories as per specifications attached and as per direction of engineer in-charge. Light fittings shall be shipped from the manufacturer's warehouse directly to Indian Oil site irrespective of quality and location of IOC's site. Each lot of fittings shall accompany test certificates LM79 / IS:16106 and reference / Batch Nos of LEDs & fittings for vertification at site. | b46 | 6 | EA |
|---|
| 47 | 47 | RECESS MOUNTED 100-120 WATT UNDER CANOPY (As per Tender Specifications ) | b47 | 6 | EA |
|---|
| 48 | 48 | RECESS MOUNTED 80-90 WATT UNDER CANOPY (As per Tender Specifications) | b48 | 10 | EA |
|---|
| 49 | 49 | (B) Urmila Petroleum | b49 | | |
|---|
| 50 | 50 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth within and outside site to unobjectionable place, disposed earth to be levelled and neatly dressed. | b50 | | |
|---|
| 51 | 51 | i) All kinds of Soil | b51 | 32 | M3 |
|---|
| 52 | 52 | Extra for excavation for every additional lift of 1.5m or part thereof in ALL KIND OF SOIL | b52 | 9 | M3 |
|---|
| 53 | 53 | Supplying and Local sand filling within the grading zone V of fine aggregates specified in table 3.1 , clause 3.1.3 of attached specifications, in plinth, under floors etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming watering and dressing complete | b53 | 21 | M3 |
|---|
| 54 | 54 | Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering - All work up to plinth level : | b54 | | |
|---|
| 55 | 55 | iii)1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) | b55 | 1 | M3 |
|---|
| 56 | 56 | v)1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) | b56 | 1 | M3 |
|---|
| 57 | 57 | viii)1:4:8(1 Cement :4 Coarse Sand : 8 Graded stone aggregate of 40mm) | b57 | 2 | M3 |
|---|
| 58 | 58 | Centering and shuttering including strutting, propping etc. and removal of form work for PCC | b58 | | |
|---|
| 59 | 59 | i) C&S for PCC in foundations,footings,bases of column | b59 | 15 | M2 |
|---|
| 60 | 60 | Providing and laying in position specified grade of reinforced concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level | b60 | | |
|---|
| 61 | 61 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm | b61 | 13 | M3 |
|---|
| 62 | 62 | Centering and shuttering including strutting, propping etc. and removal of form for : | b62 | | |
|---|
| 63 | 63 | i) Foundations,footings,bases of columns, etc. for mass concrete | b63 | 100 | M2 |
|---|
| 64 | 64 | Supply of Reinforcement for R.C.C. including straightening, cutting, bending, placing in position & binding all complete at all levels | b64 | | |
|---|
| 65 | 65 | ii)Thermo Mechanically Treated Bars Fe- 500 grade,Conforming to IS1786 | b65 | 1350 | KG |
|---|
| 66 | 66 | Providing and laying Brick work with bricks of class designation 75 Including Scaffolding : | b66 | | |
|---|
| 67 | 67 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH | b67 | 7 | M3 |
|---|
| 68 | 68 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters,sills,facias,Pump Island & similar locations of required size of shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement mixed with matching pigment,epoxy touch ups, including rubbing,curing moulding & polishing to edge to give high gloss finish etc. complete at all levels. | b68 | | |
|---|
| 69 | 69 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | b69 | 1000 | KG |
|---|
| 70 | 70 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: | b70 | 8216 | KG |
|---|
| 71 | 71 | Providing & fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.50mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, with 5-7 micron epoxy primer and polyester top coat of 15-18 micron on both sides,total coated thickness(TCT) of 0.58mm.Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. | b71 | | |
|---|
| 72 | 72 | ii) Plain Sheet for Ridges (500 - 600mm). | b72 | 18 | M2 |
|---|
| 73 | 73 | iii) 160 mm diameter PVC Rain water pipe | b73 | 24 | M |
|---|
| 74 | 74 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of cold rolled steel sheet conforming to IS 513, having minimum yield stress of 240mpa & minimum tensile stress of 300mpa.Base metal thickness 0.45mm for ceiling panels and 0.55mm for carriers. The sheet shall be hot dip metallic coated with Zinc coating ( galvanising) as per IS 277, coating mass of 120gsm on both sides, over which organic coating with Modified polyester paint on a continuous coil coating line. Top side of ceiling panels and carrier shall have 15 micron modified polyester paint over 5 micron epoxy primer and Bottom side with Alkyd back coat over 5 micron primer Total coated thickness for Panels to be 0.50mm and for carriers 0.60mm. The ceiling panels shall be clipped in to carriers, suspended from steel/trusses /other members with the help of suspension angle of 25x25x0.5mm by means of rigid suspension system meant for exterior. Longitudinal joints of two panels shall be but jointed with special type of panel splice to be fixed from inner side.Carrier shall be jointed with carrier splices maintaining a module of 150mm | b74 | 192 | M2 |
|---|
| 75 | 75 | ii) 12mm Cement plaster of mix1:6 (1 cement: 6 coarse sand) | b75 | 200 | M2 |
|---|
| 76 | 76 | Applying one coat of cement primer of approved brand and manufacture on wall surface : | b76 | 200 | M2 |
|---|
| 77 | 77 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more over an under coat of suitable shade with ordinary paint of approved brand and manufacture. | b77 | 350 | M2 |
|---|
| 78 | 78 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications of Engineer-in- charge | b78 | 75 | M3 |
|---|
| 79 | 79 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty | b79 | | |
|---|
| 80 | 80 | ii) 150 mm dia. R.C.C. pipe | b80 | 40 | M |
|---|
| 81 | 81 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate | b81 | 32 | EA |
|---|
| 82 | 82 | Providing & laying 80mm thick factory made Lacquered finish Grey/ Coloured Pre-cast cement concrete, interlocking paver block of M 40 grade made by block making machine with strong vibratory compaction & of approved size and design/ shape ,shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength than 40 N/Sq.mm as per IS15658 maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length & width and +/- 3mm on thickness. The job includes supplying & laying a layer of 50mm thick clean course sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand,compacting with machine vibrator to required line and level, etc. complete .(Payment for provision of edge restraints shall be made separately) | b82 | 1050 | M2 |
|---|
| 83 | 83 | Providing and fixing 700mm wide rain water gutter fabricated out of 1200mm wide Roll of 18 Gauge Aluminium sheets including MS clamp supports, fittings, fasteners etc. complete as per drawing . (NO joints shall be provided in the gutter and the same has to be fabricated from a continuous roll of Aluminium sheet) | b83 | 22 | M |
|---|
| 84 | 84 | Providing & fixing BARE Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.55 mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. | b84 | 192 | M2 |
|---|
| 85 | 85 | Supply and Laying 3 Core x 1.5 sq. mm. (copper)Armoured cable as as per specifications and direction of Engineer in charge | b85 | 120 | M |
|---|
| 86 | 86 | Supply and Laying 3 Core x 2.5 sq. mm Copper Cable FRLS as per specifications and direction of Engineer in charge | b86 | 185 | M |
|---|
| 87 | 87 | Supply and Laying 4 Core x 2.5 sq. mm Copper Cable FRLS as per specifications and direction of Engineer in charge | b87 | 50 | M |
|---|
| 88 | 88 | P/F Cable termination for 3 Core x 1.5 sq. mm. with FLP double compression glands, lugs etc. as per specifications and direction of Engineer-in charge. | b88 | 1 | EA |
|---|
| 89 | 89 | P/F Cable termination for 3 Core x 2.5 sq. mm with FLP double compression glands, lugs etc. as per specifications and direction of Engineer-in charge. | b89 | 6 | EA |
|---|
| 90 | 90 | Supply & Laying Earthing 25 x 3 mm GI strip as per specifications and direction of Engineer in Charge. | b90 | 150 | M |
|---|
| 91 | 91 | S/I of MCB distribution board /double door with 8 way (4+24) TPN, as per specifications and direction of Engineer in Charge | b91 | 1 | EA |
|---|
| 92 | 92 | S/F Miniature Circuit Breakers of approved make of ratings 6A to 32A DP MCB, as per specifications and direction of Engineer in Charge | b92 | 4 | EA |
|---|
| 93 | 93 | S/E of 5 Meter high galvanised Octagonal pole with top 60mm (A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) | b93 | 6 | EA |
|---|
| 94 | 94 | Supply & Fixing of 90 to 100W LED fixtures with fittings and accessories for yard lighting purposes. The LED (Light emitting diode) of 100W should be operating under voltage range of 140-277V with power factor more than 0.9CCT (Correlated colour temperature) shall be 5700 Kelvin (5665K +/- 335K), CRI (Colour rendering index) not less than 65 and LED efficacy of minimum 120 Lumens / watt. The fittings shall conform to IP65 protection class with under pressure die cast Aluminium housing with 4mm thick toughened glass. The luminaire system should have a minimum efficacy of 90 Lumens per watt. The driver shall be of constant current type with internal surge protection. Supply of complete fitting with all accessories as per specifications attached and as per direction of engineer in-charge. Light fittings shall be shipped from the manufacturer's warehouse directly to Indian Oil site irrespective of quality and location of IOC's site. Each lot of fittings shall accompany test certificates LM79 / IS:16106 and reference / Batch Nos of LEDs & fittings for vertification at site. | b94 | 6 | EA |
|---|
| 95 | 95 | RECESS MOUNTED 100-120 WATT UNDER CANOPY (As per Tender Specifications ) | b95 | 6 | EA |
|---|
| 96 | 96 | RECESS MOUNTED 80-90 WATT UNDER CANOPY (As per Tender Specifications) | b96 | 10 | EA |
|---|