Uttar Pradesh Jal Nigam-UPJN has published Construction Of Modular Operation Theatre And Associated Works In Department Of Surgery At Gsvm Medical College , Kanpur. Submission Date for this Tender is 30-08-2019. Building Work Tenders in GSVM Medical College Kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21449414
Construction Of Modular Operation Theatre And Associated Works In Department Of Surgery At Gsvm Medical College , Kanpur
Open Tender
Indian
Uttar Pradesh
GSVM Medical College Kanpur
30-08-2019

Tender Details

construction of Modular Operation Theatre And Associated Works In Department Of Surgery At Gsvm Medical College , Kanpur

Key Value

Document Fees
INR 22400 /-
EMD
INR 2000000.0 /-
Tender Value
INR 19.91 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OF MODULAR OPERATION IN DEPARTMENT OF SURGERY AT G.S.V.M. MEDICAL COLLEGE KANPUR.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Support Structure Support structure should be made of GPSP profile required for installing panels on the walls of the operating room. Warranty 12 months from installation. item1 8 SET
2 2 Ceiling Panels (Imported) Ceiling Panels of operating rooms should be and made of metal panels of adequate thickness for use in operation theatres. Mechanical robust support structure must be used to install these ceiling panels. \nThe ceiling must be in a shade of white / light grey to provide a calm environment inside the operation theatre. \nThe authority letter from the principal is compulsory to avoid duplicacy. Warranty 12 months from installation. The panels should be as per EN (European ) standards. item2 8 SET
3 3 Laminar Air Flow Ceiling System/ Clean Air System The ceiling filtration system should be designed to ensure unidirectional/ Vertical Laminar Air Flow System of clean air into the operation theatre and the exit of the contaminated air out of the operation theatre through the return air ducts/Exhaust air shafts. The Plenum box should be made of Aluminum sheet (60601 T5) minimum 1.5mm thick. Size minimum 2400mm x 2400mm\nSystem should comprise of thick extruded aluminum profiles frame and sealed gasket.\nThe volume supply of different sizes of Laminar Air Flow Ceiling is as follows: \n2400mm x 2400mm – minimum 4500m3/hr at approx. 0.24 m/s average velocity. The Plenum air/ Laminar flow should have installed with horizontally placed HEPA filters of H–13 class. The Laminar flow system should have light diffusers consisting of two layers of monofilament precision woven polyester of uniform porosity with an open area of sufficient resistance to create laminar flow from diffuser face.\nAir should diffuse into the theatre uniformly over the total area. The range of ventilated ceiling should provide the sterility cleanliness required for OT environment. Integral lightening should provide an illumination in operating area. Perfect tightness should be guaranteed by an epoxy seal between filters and holding structure disabling “by pass” of HEPA filters. The filters installed in the plenum should be suitable for applications for laminar flow and clean rooms.\nFilters should meet the following specifications: Protective grids -White epoxy painted micro drawn; Grid –Separators continuous Thermoplastic Chords; Sealant-Polyurethane; Gasket-One piece polyurethane; MPPS average-99.95% efficiency; 0.3 micron DOP- 99.999% Efficiency; Final pressure drop-600 Pa (Maximum); Max. operating temperature-60 degree Celsius; Maximum RH – 40-50 percent; Efficiency tests- Filters individually tested and certified. Test certificate of the filters must be provided; The return air ducts should be openable and cleanable; Warranty 12 months from installation; Manufacturers test certificates should be submitted with supply.\nExhaust Air Shafts/ Return Air Duct:- Especially design with same material used for wall system Return Air Duct/ Exhaust Air Shafts should be provided 4 nos. in each OT. Each of these exhaust shafts should have exhaust grill/mesh to exhaust contaminated air from top & bottom sides. These grill/ mesh should be openable access from the front for routine/ period cleaning of accumulated bacteria. item3 8 SET
4 4 Antistatic Flooring- ESD Vinyl It should be with 2mm antistatic (ESD) seamless Poly Vinyl Chloride (PVC) flooring. Total weight 3000 g/m2. Floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation (ESD) combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used, and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratchproof also. The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. The electrical resistance (point to ground) should be within 2.5x10^4 to 5x10^6 ohms. It should confirm to EN 1081, EN1815 standards. The floor should not allow buildup of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx.25mm and sealed perfectly and uniformly. Self-leveling compounds should be used. It should be scratch resistant, fire resistant, chemical resistant, slip resistant, bacterial resistant, dimensional stability <0.40%, static electrical charge < 2kV, electrical resistant. The conductive copper grid laid underneath the PVC sheet should be supported by liquid epoxy compounds allowed to set as a uniform and level surface. The copper strips to be made visible by grinding and no copper strip should project more than 0.5mm above level surface to avoid damage to the PVC sheet. One earthing lead should be brought out from every 150sq.ft area and attaching it to the main earthing strip/ground. Copper grounding strips (0.05 mm thick, 50 mm width) should be laid flat on the floor in the conductive adhesive and connected to copper strip of grounding. The connection from copper grid should be brought out uniformly at places to form equipotential grid. Flooring should be mechanically shock proof, scratch proof, flame retardant and anti-microbial. Corners should be uniformly curved. Final surface should be noncorrosive to biological fluids and detergents. Colour should be uniform pleasant and matching with ambience and as approved by respective consignee. Self leveling inside OT up to 3 mm Suitable self leveling should be done before PVC flooring to avoid undulation within the MOT. warranty 12 month from installation. item4 8 SET
5 5 X-Ray Viewer Twin plate x-ray viewing screen which should have following features. It should be designed to provide a high level of control luminance. It should have dimming range 3 – 100% flicker free illuminated by 4 pieces of high frequency fluorescent lamps. Warranty 12 months from installation. item5 8 Nos
6 6 Rounded Corners (Imported) Rounded corners should be made of aluminium of minimum thickness 1.6mm and should be integrated into the floor and inserted into the wall panelling. This is used to avoid a right angle formation at the intersection of wall and floor which will enable easy cleaning and disinfection. Warranty 12 months from installation. item6 8 SET
7 7 Automatic Doors/ Hermetically Sealing Door (Imported) 1500 X 2100 FOR DOCTORS ENTRY All Doors Should be made of HPL and Color should match the interior. The overall thickness of the finished door should be 40-60mm. The inner part of the door should be filled with CFC free polyurethane foam thickness of 48mm or nearby. (Sealed airtight to prevent further ingress of any microbial organism). \nThe door size should be as follow:\n1500 x 2100 for doctors’ entry, 1000 x 2100 for patient entry. This should be a hermetically sealed, single sliding door.The controller should be capable of being operated by elbow switches/foot switches as well as touch less sensor. The track should be of stainless steel/Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement.\nThe door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/Aluminium track to enable smooth and noiseless movement. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential). Air tightness 99.99% at a pressure of 100Pa.\nThe finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). Opening and closing of the door should be microprocessor controlled electromechanical movement. \nOne should be able to open and close the door effortlessly incase of failure of automatic mechanism. Door opening handle should be strong and sturdy. Material should be of SS (gloss finish). Should be provided with high quality cylindrical lock. The door and controls should comply with IEE regulation. All motors used should be DC brushless motors with essential isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed. Door movement should have minimum noise. The starting time after receiving the signal should be adjustable between 0.5 to 20 seconds. Warranty 12 months from installation. item7 8 Nos
8 8 Automatic Doors/ Hermetically Sealing Door (Imported) 1000 X 2100 FOR PATIENT ENTRY All Doors Should be made of HPL and Color should match the interior. The overall thickness of the finished door should be 40-60mm. The inner part of the door should be filled with CFC free polyurethane foam thickness of 48mm or nearby. (Sealed airtight to prevent further ingress of any microbial organism). \nThe door size should be as follow:\n1500 x 2100 for doctors’ entry, 1000 x 2100 for patient entry. This should be a hermetically sealed, single sliding door.The controller should be capable of being operated by elbow switches/foot switches as well as touch less sensor. The track should be of stainless steel/Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement.\nThe door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/Aluminium track to enable smooth and noiseless movement. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential). Air tightness 99.99% at a pressure of 100Pa.\nThe finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). Opening and closing of the door should be microprocessor controlled electromechanical movement. \nOne should be able to open and close the door effortlessly incase of failure of automatic mechanism. Door opening handle should be strong and sturdy. Material should be of SS (gloss finish). Should be provided with high quality cylindrical lock. The door and controls should comply with IEE regulation. All motors used should be DC brushless motors with essential isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed. Door movement should have minimum noise. The starting time after receiving the signal should be adjustable between 0.5 to 20 seconds. Warranty 12 months from installation. item8 8 Nos
9 9 Peripheral Lighting and Clean Room Luminaries IP-65 (LED Type) (Imported) To provide peripheral lighting and clean room luminaries with intensity min 500 Lux, it should be minimum 8 in numbers for each OT. Should be with highly specular anodized aluminum reflectors and optical antiglare system.\nLuminaries cover should be made of highly resistant, disinfectant proof laminated safety glass/acrylic with stylish fine-grained surface. The reflectors should be of high quality, cleanable and non-deteriorating. The luminaires body should be made of sheet steel/ perfectly powder coated, supplied ready for connection optionally for individual or series circuit with digital electronic control gear. Recess frames should be gas tight. The fitting should be flush with the ceiling and should be removable from top or bottom. The light fitting should be uniformly and aesthetically distributed on the ceiling to provide uniform illumination in the OT. Light should not interfere when green mode endoscopy is performed.\nPeripheral lighting should be done according to IP65 (international protection rating 65).\nControl equipment for the general lighting and the light dimming should be provided in the theatre control panel. Warranty 12 months from installation. item9 64 Nos
10 10 Writing cum List Board Operating writing list board to be used for surgeon / Anesthetist. Its should be flush mounting type. \nIt should be made of high-grade GP sheet or powder coated CRC material of size minimum 900mm x 700mm x 60mm having magnetic properties, complete with all accessories etc. Warranty 12 months from installation. item10 8 Nos
11 11 Medical Gas Pipeline Copper tube and fitting must be manufactured as per BS EN 13348:2001. The medical grade copper pipes should be Phosphorous deoxidized, non-arsenic, degreased seamless round tubes (Grade: CW024QA / Cu-DHP) conforming to EN 13348:2001. The mechanical properties of copper tube should be in accordance with BS EN 13348:2001/2008 in either R250 half hard or R290 hard. Degreasing of pipe shall be such that there is less than 20mg/m2. All Pipes must be manufactured, calibrated, tested & Lloyds Certified as per specifications BS EN 13348:2001 +A1/ ASTM: B 819-00. The supplies of copper pipe should be accompanied with manufacturers test certificate for the physical properties and Chemical composition. Further substantiated with inspection certificate from the third parties like SGS/Lloyds Register.\nAll sizes from 12mm to 108mm (As per requirement) shall be from same manufacturer confirming to the quality parameters and specifications referred above. Labeling on copper tube will contain date, time and code of manufacture. The supplier should provide Manufacture’s Test Certificate of copper pipes for physical properties and chemical composition. CUDHP to ISO 1190-1 complete with 024a to EN 1412-1996 It should be third party certified. Copper Pipes joint by silver brazing method for copper to copper. Inert gas welding technique should be used by passing. Nitrogen gas inside the copper pipes during silver brazing, in order to avoid carbon deposition inside the copper pipes. Copper pipes to be fixed with walls with suitable saddles and supported After erection, all the pipes should be cleaned or purged with the help of dry nitrogen gas, & should be tested with dry nitrogen at a pressure of 1.5 time of working pressure for 24 hour The copper pipes for medical gas and vacuum system should be of following size:\n• 28 mm. OD x 0.9mm. Thickness \n• 22 mm. OD x 0.9mm. Thickness \n• 15 mm. OD x 0.7mm. Thickness Safety parameters • as per tender spesification attached to tender document item11 8 SET
12 12 Oxygen Manifold Supply System (Without Cylinders) The size of Manifolds should be 2x10 and it should be compatible with Class-D type bulk cylinders.\nManifold should consist of two high pressure header bar assemblies to facilitate connection of primary and secondary cylinder supplies.\nEach header bar should be provided with respective numbers of cylinder pigtail connections to suit cylinder valves as per IS.3224/BS/ ASME incorporating a check valve at the header connection. Each header bar assembly should be provided with a high pressure shut off valve. Oxygen Manifold should consist of 2 rows of respective numbers of class D-type bulk oxygen cylinders. The manifold should be hydraulically tested to 3500 psig. The manifold should be so designed that it should suit easy cylinder changing and positioning. \nThe system should have non – return valves and for easy changing of cylinders without closing the bank. The cylinder should be placed with the help of cylinder brackets and fixing chains which should be galvanized. Warranty 12 months from installation. item12 1 SET
13 13 Emergency Oxygen Manifold (Without Cylinders) The size of Manifolds 4 Cylinder and it should be compatible with Class-D type bulk cylinders.\nManifold should consist of high pressure header bar assemblies to facilitate connection of respective numbers of primary and secondary cylinder supplies. \nEmergency oxygen manifold should be fitted with high pressure regulator. Header bar should be provided with respective numbers of cylinder pigtail connections to suit cylinder valves as per IS.3224/ BS/ ASME. The manifold should be hydraulically tested to 3500 psig. \nThe manifold should be so designed that it suits easy cylinder changing and positioning. The system should have non – return valves for easy changing of cylinders without closing the bank.\nThe cylinder should be placed with the help of cylinder brackets and fixing chains which should be galvanized. Warranty 12 months from installation. item13 1 SET
14 14 Duplex Vacuum Pump (Minimum 1000 LPM Each) The Vacuum System should include two medical Vacuum pumps each with electrical motors, silencers and one vacuum tank. Specification:\n- Vacuum Pump: 2 Nos. \n Type: 7V, reciprocating, single stage.\n Capacity: 110 cfm (each Vacuum Pump). \n Vacuum: 754.4 mm Hg (up-to). Cooling: Air Cooled.\n Starting: Unloaded.\n- Drive Data \n Motors: 2 Nos.\n Capacity: 7.5 H.P.\n Type: Induction motor, TEFC\n Drive: Belt drive\n Electric supply: 440 Vac., 50 Hz, 3 Ph. The system to provide duplex/cascade vacuum system for automatically start and stop at 480 mm and 650 mm HG. Provision shall be made so that when one pump stops, the second pump is set to automatically start on the next starting pulse and vice versa. In the event any pump fails, the system would automatically revert to the other pump. Bacterial Filters The filters should be capable of removing more than 99.9% of oil and smoke particles from the exhaust. Warranty 12 months from installation. item14 1 SET
15 15 Vacuum Tank (Capacity 1000ltr.): One number welded type reservoir made of steel plate as per IS:2062 and fabricated as per IS:2825 for a vacuum pressure of 760 mm of mercury. The tank should be equipped with drain valve and vacuum gauge the inside of the tank should be coated for rust protection with a double component coating which should provide a hard, durable lining. Warranty 12 months from installation. item15 1 SET
16 16 Electrical Wiring and Conduiting of O.T. Wiring with Low Leakage Current wires of FRLS wires including providing and fixing of PVC conduit and boxes etc. to complete the work in all respects. Wiring for 240 volts single phase & neutral 6/16 amps switches socket with 4 Sq mm PVC insulated copper conductor 1100 volts grade standard flexible wires in concealed surface mounted 25mm dia16 gauge PVC conduit including providing and fixing of 6/16 amps 5 pin switch socket of approved make and design in 1mm thk. G.I. box with grid plates and earthing the third pin of each socket outlet with 4 Sq mm PVC insulated copper conductor trended flexible wire. \nProvision for UPS wiring and sockets within the O.T. with Electrical Distribution board for Operating room with MCB's and Relay cards. Fire test as per BS 6387 CWZ. Warranty 12 months from installation. Warranty 12 months from installation. item16 8 SET
17 17 Pressure Relief Dampers Pressure relief dampers (PRD) should be provided in each room to prevent contamination of air from clean and dirty areas. Suitably sized air pressure relief damper should be strategically placed, enabling differential room pressure to be maintained and ensured when doors are opened between Operating room and the corridor. Counter-weight balancing system should be provided in the PRD to maintain positive pressure inside the operation room. Air pressure stabilizers should have unique capability of controlling differential pressure to close tolerance. The PRD should remain closed at pressure below the set pressure and should open fully at pressure. The body should be epoxy powder coated. Stainless Steel 304 Grade should be used for body and high grade SS 304 stainless steel for blades. Warranty 12 months from installation. item17 8 Nos
18 18 Electrical Panel, cabling and wiring for Electrical Generator item18 1 LOT
19 19 Operation Theatre Management System (Hardware + Software):- The system should record, maintain as well as keep track of scheduled patient surgeries in the hospital. This system should optimize the surgery scheduling process thereby reducing the paper work and delay caused by manual record maintenance. \nThe system should provide digital surgery scheduling, which would support the hospital in improving the record management and forecasting the availability of the OTs. The system should be capable of sending alerts/acknowledgements to the patients / Hospital staff (as decided by the hospital administration).\nThe system should be robust, flexible & upgradable with the capability to add modules and should have the provision to be integrated with information system being used by the hospital. The system should be a secured application with the access enabled only to authorized users (as decided by the hospital administration). The system should have a functionality to allow the user to perform application related Master data management allowing the smooth application flow and execution The master data management module should comprise of functionality to allow the user to create / update / manage the respective master records. This should in turn reduce the time spent by the user and patient while registration. \nThe system should have the functionality to allow the user to create / update / manage the list of patients that are planned to be taken up for scheduled surgeries. \nThe system should have the functionality to allow the user to create / update / manage the list of Operation Theater room booking details. The system should allow the user to select the details of surgery to be performed and have the option of entering the name of the surgeon performing the surgery. The system should have the functionality to validate the date and time of planned surgery details entered, as far as possible, to avoid overlapping of surgeries (exceptional situations such as extended surgeries / non-availability of required resources or medical staff / non-functional equipment etc or any other reason is not in this scope) Technical specifications :- (as descrived in specification attached with tender document) item19 1 Nos
20 20 Dismanting existing plaster including disposal of refuse as directed by the Engineer in charge within a distance of 60 meter (200 feet) item20 769.57 SQM
21 21 Dimantling brick work or stone work in lime or cement morter and including stacking of materials as directed by the Engineer-in-charge with in a distance of 60 meter. item21 20.59 CUM
22 22 Recunstruction of wall with Brick work Class 150 Brick work in 1:4 cement & course Sand mortar in foundation and plinth including supply of all materials, labour and tools and plants etc., required for proper completion of work same as above but in super structure above plinth level up to floor to level (upto 2 storeys) including accessories cuting and moulding of brick work as required and including honey combed including thikness of wall more then 12cm item22 32.52 CUM
23 23 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing item23 184.5 SQM
24 24 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. item24 350 KG
25 25 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. item25 4.55 CUM
26 26 Providing and laying integral cement based treatment (Brick coba) for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in - charge and consisting of : (i) 1st layer of 22 mm to 25 mm thick approved and specfied rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement :3 coarse sand) mixed with water proofing compound confirming to IS : 2645 in the recommended proportion over the levelling course (levelling course to be paid separately). Joints sealed and grouted with cement slurrry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Fininshing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sdm throughly embedded in the 2nd layer. item26 233.65 SQM
27 27 12 mm thick plaster in single coat on fair side of single or half brick thick wall for interior plastering upto floor two level including internal rounded angles chamfers, and/or not exceeding 80 mm. In girth and finished even smooth. No extra for mixing any additive with cement and approved coarse sand ratio of 1:3. item27 836.32 SQM
28 28 Providing and laying of 8 to 10 mm thick ivory or light shade vitrified tiles of 600x600mm size in wall, flooring or skirting laid with 1:3 (1 cement : 3 coarse sand), finished with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T&P required for proper completion of the work. item28 410.06 SQM
29 29 2.5cm (1'') thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 2 cm. (1") graded approved stone grit, laid in panels finished with 3 mm (1/8") floating coat of neat cement of cement and marble dust in ratio 5:1 as specified over and including 8 cm (3") thick base concrete consisting of cement, fine sand of 1.25 finesess modulus and brick ballast 4cm. (1.1/2") gauge in proporation of 1:4:8 and removing any overlapping morter at the joints of the penals if any and removing any overlapping morter at the joints of the penals if any and giving them a uniform finish, including supply of all materials, labor, tools & plans etc. required for proper completion of the work. (without base concrete.) item29 250.96 SQM
30 30 Self Leveling upto 3mm inside OT rooms item30 8 JOB
31 31 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Raj Nagar Plain white marble/ Udaipur green marble/ Zebra\nblack marble. Area of slab over 0.50 sqm item31 14.88 SQM
32 32 Internal water supply & best material dispose item32 1 JOB
33 33 External water & dispose watre work item33 1 JOB
34 34 Finishing wall with premium Acrylic smooth Exterior paint with silicone additives fo required shade: including New Work (Two or more coats applied @1.43 ltr/10 sqm over and including priming coat of exterior primer manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. item34 600 SQM
35 35 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials, with 1 mm thick white cement based putty.(wall & Ceiling Surface) item35 50 SQM
36 36 Supply & Fixing of M.S. Fabrication wire mess jali size 25mm X 25mm heavy labour T & P etc all complete of work. item36 50 SQM
37 37 Supply and laying of Aluminium conductor PVC insulated armoured served seathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-in-charge, complte in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 240 sq. mm-3-1/2 core item37 300 RMT
38 38 Supply and laying of Aluminium conductor PVC insulated armoured served seathed, underground cable including rubber ring etc. Complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. 240 sq. mm-3-1/2 core item38 6 Nos
39 39 supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. Complete in all respect as per direction of the Engineer-Incharge. 240 sq. mm item39 15 Nos
40 40 supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. Complete in all respect as per direction of the Engineer-Incharge. 120 sq. mm item40 5 Nos
41 41 EARTHING AND LIGHTING CONDUCTOR :-Supply and burying of 600mm X 600mm X 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. Pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15 mm dia G.I. pipe upto switch board (from appron to switch board the cost of C.I. pipe and copper wire will be extra) 30cm square G.I. frame with higned cover masnory housing alternate layers of charcoal/coke ant salt at least 150mm thick around etc. complete in all respect. item41 8 Nos
42 42 Supply and laying of 32mm X 6mm copper strip from earth electrode directly in the ground as required complete in all respect. item42 200 Nos
43 43 Supply and burring of Safe Earthing Electrode T-39 Cu Copper Coated, Length upto 3000mm, outer pipe 76.3mm X 3.2mm inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaning capacity along with 30 cm square C.I. frame with hinged cover & masnory housing. (From electrode terminal to switch board, cost of 25 X3 copper Strip will be extra). Make : As approved in UPPWD & CPRI Certified. item43 8 Nos
44 44 Supply and laying of 25mm X 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. item44 280 RMT
45 45 Supply and burying of 40mm dia X 4.5 meteres long G.I. Pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG G.I. Wire in G.I. pipe up to appron ( and from appron to switch board the cost of G.I. wire and pipe wil be extra) upto switch board, 30cm square C.I. box with hinged cover masnory encloure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick around etc. as per directions of Engineer-in-Charge complete in all respect. item45 3 Nos
46 46 Indoor Units (Normianl Capacity) Ceiling Mounted Casssete (Round flow) Type Units with Wired Remote and refnet. supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 2.08 TR item46 12 Nos
47 47 Indoor Units (Normianl Capacity) Ceiling Mounted Casssete (Round flow) Type Units with Wired Remote and refnet. supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 1.65 TR item47 4 Nos
48 48 Indoor Units (Normianl Capacity) Ceiling Mounted Casssete (Round flow) Type Units with Wired Remote and refnet. supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 1.32 TR item48 6 Nos
49 49 Indoor Units (Normianl Capacity) Wall Mounted Hi-Wall Unitys with Wired Remote and Refnet supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 1.65TR item49 4 Nos
50 50 Indoor Units (Normianl Capacity) Wall Mounted Hi-Wall Unitys with Wired Remote and Refnet supply, Installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 1.0 TR item50 4 Nos
51 51 Air Handling Units (For OT) :- SITC of factory built F.M. Double skin, outer type, thermal beak profile made of 43mm thick panel consisting of G.I. casing of thickness .8mm complete with DIDW backward curved blower fan of static 125 mm, 6 row deep dx copper coil, followed with strip heaters of 1 kw capacity filter section with 50mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron and MERV-13 filter section (99% down to 3 micron), belt drive package with TEDC drive motor (EFF-1) complete with mixing box, drain connections, drain valve, stainless steel drain pump, complete as per above specification. 2500 cfm (125m static) item51 8 Nos
52 52 PAN TYPE HUMIDEFIRE ( FOR OT) SITC of pan type humidifier of following capacity it shall be constructed from 1 mm thick S.S. sheet with top cover openable for maintenance. The humidifier shall be with quick fill, make up overflow & drain connections. Humidifier shall be insulated with fiber glass of density 32 kg/cm3 shall be cladded with 22 G thick aluminium sheet. the humidifier is divided into two chambers from inside, one bank of heater is always kept on to maintain water temperature between 60-70 with thermostat all controls such as low level cutout, thermostat float valve shall be provide. It shall have its own electrical panel with contators,MCB,Low level cutout, heating thermostat fault including lamp etc n=in thermally. 1.5 KW item52 8 Nos
53 53 Supply, Installation, testing and commissioning of corded remotes for AHU's. item53 8 Nos
54 54 Supply, istallationn, testing and commissioning o fAHU controller Kit for connecting the outdoor & AHU (including Control Box & AHU expansion kit.) item54 8 SET
55 55 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 41.3mm dia with 19mm thick insulation item55 36 RMT
56 56 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 34.9 mm dia with 19mm thick insulation item56 24 RMT
57 57 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 28.6 mm dia with 19mm thick insulation item57 48 RMT
58 58 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 25.4 mm dia with 19mm thick insulation item58 68 RMT
59 59 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 22.2 mm dia with 19mm thick insulation item59 120 RMT
60 60 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 19.1 mm dia with 19mm thick insulation item60 32 RMT
61 61 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 15.9 mm dia with 19mm thick insulation item61 108 RMT
62 62 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 12.7 mm dia with 19mm thick insulation item62 92 RMT
63 63 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 9.5 mm dia with 19mm thick insulation item63 224 RMT
64 64 Refrigerant Piping Supplying & installation of interconnecting following sizes of one end expanded refrigerant copper pipe work with Y-joints and Headers of following outer diameter, insulated with closed cell electrometric nitride rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminum classing for all exposed pipes as per specification all piping inside the room shall be properly fixed. supported with suitable size of clamp/M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd. (The final refrigerant pipe sizes shall be alas per manufacture). 6.4 mm dia with 19mm thick insulation item64 84 RMT
65 65 Supply and fixing of MS perforated cable tray for Copper Piping 150mm X 50mm X 1.6 mm without cover. item65 144 RMT
66 66 Drain piping Providing and fixing of PVC piping complete with fitting, supports as per specifications and insulated with 9mm thick closed cell nitrile rubber insulation. 40 mm dia item66 100 RMT
67 67 Drain piping Providing and fixing of PVC piping complete with fitting, supports as per specifications and insulated with 9mm thick closed cell nitrile rubber insulation. 32 mm dia item67 68 RMT
68 68 Drain piping Providing and fixing of PVC piping complete with fitting, supports as per specifications and insulated with 9mm thick closed cell nitrile rubber insulation. 25 mm dia item68 120 RMT
69 69 Electrical Panels: Supply, Design, Installation, Testing & Commissioning of LT Panel floor mounted, outdoor type cubical panel made out of 16 SWG thick CRCA sheet, dust and vermin prrof, lockable hinged doors with 16 SWG thick gland plat. Panel will be powder coated of color siemens grey shed. The Panel including providing and fixing the following switchgear as required. (CPRI Approved Vendor) Panel - 1 INCOMER: 1 nos. 500 A TPN MCCB (36KA) with soild netural link (01 No.) METERING & INDICATION: Amp Meter (01 No), Volt meter (01 No.), Phase Indicating Light LED type (01 Set), Control MCB 6 Amp. (03 Nos) BUS-BAR TPN Aluminium busbar 630 Amp with color coded heat shrinkable sleeves. (01 set) OUTGOINGS:\n8 Nos # 25 amps TPN MCCB for outdoor\n3 Nos # 40 amps TPN MCCB for outdoor.\n8 nos # 25 A 4 Pole MCCB with 16 DOL starter for 8 no ahus, overload relay, start / stop push buttons, phase indication lights with protection fuse, on / off / trip indication light with protection fuse, single phase preventer & auto / manual mode selector switch. 8 nos # 25 A 4 Pole MCCB with 16 DOL starter for 8 no strip heater bank overload relay, toggle switch, phase indication lights with protection fuse, on / off / trip indication lightswith protection fuse, single phase preventer & auto / manual mode selector switch. 8 nos # 25 A 4 Pole MCCB with 16 DOL starter for 8 no pan type humidifier overload relay, toggle switch, phase indication lights with protection fuse, on / off / trip indication lightswith protection fuse, single phase preventer & auto / manual mode selector switch.\n item69 1 SET
70 70 Electrical Panels: Supply, Design, Installation, Testing & Commissioning of LT Panel floor mounted, outdoor type cubical panel made out of 16 SWG thick CRCA sheet, dust and vermin prrof, lockable hinged doors with 16 SWG thick gland plat. Panel will be powder coated of color siemens grey shed. The Panel including providing and fixing the following switchgear as required. (CPRI Approved Vendor)\nPANEL-2\nINCOMER: 1 nos. 200 A TPN MCCB (36KA) with soild netural link (01 No.)\nMETERING & INDICATION Amp Meter (01 No), Volt meter (01 No.), Phase Indicating Light LED type (01 Set), Control MCB 6 Amp. (03 Nos)\nBUS-BAR= TPN Aluminium busbar 300 Amp with color coded heat shrinkable sleeves. (01 set)\nOUTGOINGS: 2 Nos # 25 amps TPN MCCB for outdoor\n2 Nos # 40 amps TPN MCCB for outdoor\n2 nos # 25 A 4 Pole MCCB with 16 DOL starter for 2 no ahus, overload relay, start / stop push buttons, phase indication lights with protection fuse, on / off / trip indication light with protection fuse, single phase preventer & auto / manual mode selector switch.\n2 nos # 25 A 4 Pole MCCB with 16 DOL starter for 2 no strip heater bank overload relay, toggle switch, phase indication lights with protection fuse, on / off / trip indication lightswith protection fuse, single phase preventer & auto / manual mode selector switch.\n2 nos # 25 A 4 Pole MCCB with 16 DOL starter for 2 no pan type humidifier overload relay, toggle switch, phase indication lights with protection fuse, on / off / trip indication lightswith protection fuse, single phase preventer & auto / manual mode selector switch.\n\n item70 1 SET
71 71 Supply and fixing of DB Box for Cassette and Hi-wall type Indoor units power supply along with 5 Amp, MCB Complete as required item71 4 SET
72 72 Modular wall Paneling System\na) Walls Panels Both Side Antibacterial.\nThe Operation Theatre wall system should be impact resistant, resistant to solvents & chemicals, prevent colonizing of micro-organisms or neutralize micro-organisms which come into contact with the surface. \nThe surfaces should be stable–prevent cracking and movement, scrub able –amenable to cleaning and disinfection, therefore, Walls should be made of minimum 10mm thick high-pressure laminate antibacterial panels.\nThese panels should be EN Standard and permanent antibacterial on both sides (back and front) with at least 15 years guarantee. \nThe panels should consist of layers of cellulose fibrous material impregnated with thermosetting resins and bonded together in a high pressure process (>5 mpa) with simultaneous application of heat (>1200C). The panels should be nontoxic and should be free of chloride organic substances. The panels should act against MRSA that are commonly found in operation theaters.\nThe surfaces should be free of any kind of paint. It should be highly resistant against temperature, pressure, heat, light and humidity. It should be chemically inert to avoid oxidation and corrosion. \nThe panels should be non-porous smooth surface easy to clean with any hospital disinfectant. It should be able to endure highest material exposure without any visible signs of wear. The surface should be highly scratch resistant, impact resistant and abrasion resistant and long lasting.\nThere should be an option of digitally printed glass panels or digitally printed HPL panels of appropriate dimension to suit the wall paneling system, if required. The authority letter from the manufacturer in favour of tenderer is compulsory to avoid duplicacy and to ensure the antibacterial effect of the surface of the panels. \nThe tenderer must have completed the job of supply and installation of similar wall systems in at least 8 nos. operation theatres with same specifications as asked for in this tender, in various government hospitals / Medical Colleges in India during past seven years.\nCertificates issued by an officer of the rank of Project Manager/ Additional Project Manager or higher must be submitted in support. The authority letter from the principal is compulsory to avoid duplicacy. Warranty 12 months from installation.\nThe panels should be as per EN (European) standards. item72 8 SET
73 73 Double Arm Ceiling Pendant for Surgeon (Imported) detail as per technical specification attached to the tender document item73 8 Nos
74 74 Double Arm Ceiling Pendant for Anesthesia (Imported) detail as per technical specification attached to tender document item74 8 Nos
75 75 LED Operation Theatre Light (Imported) detail as per technical specification attached to tender document item75 8 Nos
76 76 Camera with Minimum 27" Medical Grade Monitor detail as per technical specification attached to tender document item76 4 SET
77 77 Touch Screen Surgeon Control Panel Should be installed inside the OT room and complying with relevant provisions of council directive 93/42/EEC. \nThe touch screen control panel should be IP based with remote monitoring option, front access only, flushed with the wall and should consist of the following:\nWarranty 12 months from installation. 1. Display for time elapsed Digital clock\n2. Standard Digital clock\n3. Humidity and Temperature display- Digital type\n4. Power On/Off control for Planair Ceiling light \n5. Power On/Off control and dimming for Peripheral light 6. Medical gas alarm should indicate high, normal and low gas pressure for each gas services present in the operating room with audible buzzer with mute facility and conforming to EN ISO 7396-1\nThe control panel should be user friendly and ease of operating and maintaining purpose. item77 8 SET
78 78 Fully Automatic Oxygen Control Panel for Plant Room The manifold assembly should provide two stages of pressure regulation. A single stage primary regulator, one for each cylinder bank should be used to initially reduce cylinder pressure and two single stage pressure regulators should be provided in the control cabinet for final delivery pressure regulation. \nThe two high pressure reducers should be linked to right and left manifold of cylinders. Moreover, the second stage reducers should be also separately in order to be isolated. One delivery pressure regulator in service and one should be ready for service in a standby mode. The Manifold control panel should be pneumatically driven, fully automatic type and switches from “Bank in Use” to “Reserve bank“ without fluctuation in delivery supply line pressure. Instruction for changing the cylinders should be clearly identified on the front of the control panel.\nAll functional components should be enclosed in corrosion resistant painted. All components inside the Control Panel like Pressure, piping and control switching equipment should be cleaned for Oxygen Service and installed inside the cabinet to minimize tampering with the regulators or switch settings.\nThe heavy-duty control panel should be provided with a flow capacity of min. 1500 LPM at 50 to 60 psi.\nShould be European CE Certified with 4 digit notified body number. The bidder must submit along with the bid the necessary authority letters from the manufacturer in favor of the bidder to participate in this tender. Warranty 12 months from installation. item78 1 SET
79 79 AGSS SYSTEM The Anesthesia Gas Scavenging (AGS) System shall comply with HTM 02-01 and BS 6834. The AGS system shall be a dedicated. Specifically designed active extraction and disposal system for waste anesthetic gas.\nIt shall provide a maximum flow rate of 130 1/min with a 1 kPa resistance to flow. and a minimum of 80 1/min with a 4 kPa resistance to flow at each terminal unit. irrespective of the number of terminal units in use the AGS system sale use dedicated redial blowers in a duplex or triplex configuration. The AGS blower assemblies shall be skid mounted and included on the skid shall be the duplex or triplex blowers, motor control unit(s) with starter/isolator, moisture drain flask and flexible connector(s) to connect the plant to the pipeline, Each blower shall include an electric motor and directly coupled impeller assembly, Impeller bearings in the blower(s) shall not require lubrication. The blowers shall be air cooled and rated for continuous.\nShould be European CE Certified with 4 digit notified body number. The tenderer must submit along with the bid the necessary authority letters from the manufacturer in favor of the tenderer to participate in this tender. Warranty 12 months from installation. C.1 Duplex/Triplex AGSS System Minimum 1300lpm each item79 1 Nos
80 80 AGSS SYSTEM The Anesthesia Gas Scavenging (AGS) System shall comply with HTM 02-01 and BS 6834. The AGS system shall be a dedicated. Specifically designed active extraction and disposal system for waste anesthetic gas.\nIt shall provide a maximum flow rate of 130 1/min with a 1 kPa resistance to flow. and a minimum of 80 1/min with a 4 kPa resistance to flow at each terminal unit. irrespective of the number of terminal units in use the AGS system sale use dedicated redial blowers in a duplex or triplex configuration. The AGS blower assemblies shall be skid mounted and included on the skid shall be the duplex or triplex blowers, motor control unit(s) with starter/isolator, moisture drain flask and flexible connector(s) to connect the plant to the pipeline, Each blower shall include an electric motor and directly coupled impeller assembly, Impeller bearings in the blower(s) shall not require lubrication. The blowers shall be air cooled and rated for continuous.\nShould be European CE Certified with 4 digit notified body number. The tenderer must submit along with the bid the necessary authority letters from the manufacturer in favor of the tenderer to participate in this tender. Warranty 12 months from installation. C.2 Control Panel for AGSS System item80 1 Nos
81 81 AGSS SYSTEM The Anesthesia Gas Scavenging (AGS) System shall comply with HTM 02-01 and BS 6834. The AGS system shall be a dedicated. Specifically designed active extraction and disposal system for waste anesthetic gas.\nIt shall provide a maximum flow rate of 130 1/min with a 1 kPa resistance to flow. and a minimum of 80 1/min with a 4 kPa resistance to flow at each terminal unit. irrespective of the number of terminal units in use the AGS system sale use dedicated redial blowers in a duplex or triplex configuration. The AGS blower assemblies shall be skid mounted and included on the skid shall be the duplex or triplex blowers, motor control unit(s) with starter/isolator, moisture drain flask and flexible connector(s) to connect the plant to the pipeline, Each blower shall include an electric motor and directly coupled impeller assembly, Impeller bearings in the blower(s) shall not require lubrication. The blowers shall be air cooled and rated for continuous.\nShould be European CE Certified with 4 digit notified body number. The tenderer must submit along with the bid the necessary authority letters from the manufacturer in favor of the tenderer to participate in this tender. Warranty 12 months from installation. C.3 Remote for ASS System item81 1 Nos
82 82 AGSS SYSTEM The Anesthesia Gas Scavenging (AGS) System shall comply with HTM 02-01 and BS 6834. The AGS system shall be a dedicated. Specifically designed active extraction and disposal system for waste anesthetic gas.\nIt shall provide a maximum flow rate of 130 1/min with a 1 kPa resistance to flow. and a minimum of 80 1/min with a 4 kPa resistance to flow at each terminal unit. irrespective of the number of terminal units in use the AGS system sale use dedicated redial blowers in a duplex or triplex configuration. The AGS blower assemblies shall be skid mounted and included on the skid shall be the duplex or triplex blowers, motor control unit(s) with starter/isolator, moisture drain flask and flexible connector(s) to connect the plant to the pipeline, Each blower shall include an electric motor and directly coupled impeller assembly, Impeller bearings in the blower(s) shall not require lubrication. The blowers shall be air cooled and rated for continuous.\nShould be European CE Certified with 4 digit notified body number. The tenderer must submit along with the bid the necessary authority letters from the manufacturer in favor of the tenderer to participate in this tender. Warranty 12 months from installation. C.4 Cabling inside Plant Room item82 1 Nos
83 83 Operating Table for General Surgery The Operating Table with electrical adjustments, modular designed back plate. It has a powered sliding table top. It has easy locking system for back - and leg plates. The table must have with stability pins extended between the castors. The base, table top and column covering made of chrome nickel steel. specifications as per technical specification attached with tender document. item83 4 Nos
84 84 UPS SYSTEM:- IGBT Rectifier & Inverter Based High Switching Frequency 20 KHz UPS system with Static Bypass.\na) 10 KVA Online UPS System with SMF Batteries for Approx. 30Minutes battery Backup.\nInput-1n. Output-1n. PF corrected to unity.\nUnique Product Features:\n• Isolation Transformer Inbuilt.\n• Input PF Corrected to unity. THD (i) < 3%.\n• Wide Input voltage window 140VAC – 270VAC \n• Built in Failsafe features.\n• Modular Assembly for minimum maintenance time. \n• Warranty 12 months from installation item84 8 Nos
85 85 Electrical Generator 500 KVA ( specification as per technical specification attached with tender document) item85 1 Nos
86 86 Fluid Waste Disposal System ( specification as per technical specification attached with tender document) item86 3 Nos
87 87 Advanced Electrosurgical Unit with Vessel Sealing Technology: ( specification as per technical specification attached with tender document) item87 1 Nos
88 88 VRV/VRF System: Supply, installation, testing and commissioning of AIR Cooled & Inverter based variable refrigerant volume type split air conditioning system with R410A suitable for 415 + 10%, 50 cycles, The Unit shall consist of indoor units & external condensing units, complete in all respects, inclusive of insulated copper refrigerant piping, drain piping of required size, electrical panel, wiring, control cabling and earthing, stands and supports with all other necessary accessories for proper functioning of the units. Outer Units - 10 HP (For OT) item88 8 Nos
89 89 VRV/VRF System: Supply, installation, testing and commissioning of AIR Cooled & Inverter based variable refrigerant volume type split air conditioning system with R410A suitable for 415 + 10%, 50 cycles, The Unit shall consist of indoor units & external condensing units, complete in all respects, inclusive of insulated copper refrigerant piping, drain piping of required size, electrical panel, wiring, control cabling and earthing, stands and supports with all other necessary accessories for proper functioning of the units. Outer Units - 20 HP item89 3 Nos