Repair And Partition Work Of Room No 57 E At Ambedkar University Delhi , Kashmere Gate Campus , Delhi, Ambedkar University Delhi, Lothian Road, Delhi-Delhi

Ambedkar University Delhi has published Repair And Partition Work Of Room No 57 E At Ambedkar University Delhi , Kashmere Gate Campus , Delhi. Submission Date for this Tender is 03-09-2019. Building Repair Tenders in Ambedkar University Delhi, Lothian Road, Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

21442481
Repair And Partition Work Of Room No 57 E At Ambedkar University Delhi , Kashmere Gate Campus , Delhi
Open Tender
Indian
Delhi
Ambedkar University Delhi, Lothian Road, Delhi
03-09-2019

Tender Details

Repair And Partition Work Of Room No 57 E At Ambedkar University Delhi , Kashmere Gate Campus , Delhi

Key Value

Document Fees
INR 236 /-
EMD
INR 4800.0 /-
Tender Value
INR 2.39 Lakhs /-

BOQ Items

Name of Work: Repair and Partition work of Room No.57-E at Ambedkar University Delhi, Kashmere Gate Campus.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 CIVIL BI01010001010000000000000515BI0100001112
2 1.01 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area 3 sq. metres and below BI01010001010000000000000515BI0100001113 2 Each
3 1.02 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For fixed portion :Powder coated aluminium (minimum thickness of powder coating 50 micron) BI01010001010000000000000515BI0100001114 83.61 Kg
4 1.03 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) BI01010001010000000000000515BI0100001114 42.48 Kg
5 1.04 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides BI01010001010000000000000515BI0100001114 11.9 Sqm
6 1.05 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness BI01010001010000000000000515BI0100001114 4.6 Sqm
7 1.06 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. BI01010001010000000000000515BI0100001114 3 Each
8 1.07 Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper BI01010001010000000000000515BI0100001114 3 Each
9 1.08 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed\nto required colour or shade, with necessary screws etc. complete 250x10 mm BI01010001010000000000000515BI0100001114 3 Each
10 1.09 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm BI01010001010000000000000515BI0100001114 2 Each
11 1.1 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed\nto required colour or shade, with necessary screws etc. complete :125 mm BI01010001010000000000000515BI0100001114 6 Each
12 1.11 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. BI01010001010000000000000515BI0100001114 1 Each
13 1.12 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the\nEngineer-in-Charge. With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles BI01010001010000000000000515BI0100001114 44.95 Sqm
14 1.13 Providing and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 2 mm thick water proofing membrance, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrance manufacture of density at 25°C, 0.87 - 0.89 kg/ litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc., and\npreparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/ 5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. 2mm (for corrugated roof sheets) BI01010001010000000000000515BI0100001114 54 Sqm
15 1.14 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead :With cement mortar 1:4 (1cement: 4 coarse sand BI01010001010000000000000515BI0100001114 2.4 Sqm
16 1.15 Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. BI01010001010000000000000515BI0100001114 33.1 Sqm
17 1.16 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. BI01010001010000000000000515BI0100001114 33.1 Sqm
18 1.17 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre BI01010001010000000000000515BI0100001114 33.1 Sqm
19 1.18 Distempering with 1st quality acrylic distemper, having VOC (VolatileOrganic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required,to achieve even shade and colour. Two coats BI01010001010000000000000515BI0100001114 33.1 Sqm
20 1.19 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coat BI01010001010000000000000515BI0100001114 37.18 Sqm
21 1.2 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material andstacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. BI01010001010000000000000515BI0100001114 44.95 Sqm
22 1.21 Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) BI01010001010000000000000515BI0100001114 11.44 Sqm
23 1.22 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved byEngineer-in-charge, beyond 50 m initial lead, for all leads including all lifts up to 10 km BI01010001010000000000000515BI0100001114 6 Cum
24 1.23 Removing existing work station(of size 2.17x1.62 approx.) and refixing it to other location in the room including all labour etc complete as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001114 3 Each
25 1.24 Removing existing work station(of size 2.17x1.62 approx.) and shifting it to ( with in 50 meter range) other location in the room as per direction of Engineer-in-charge BI01010001010000000000000515BI0100001114 2 Each
26 2 ELECTRICAL
27 2.01 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire BI01010001010000000000000515BI0100001114 20 Meter
28 2.02 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A Switch\n\n BI01010001010000000000000515BI0100001114 18 Each
29 2.03 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet\n BI01010001010000000000000515BI0100001114 18 Each
30 2.04 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch\n BI01010001010000000000000515BI0100001114 18 Each
31 2.05 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet\n BI01010001010000000000000515BI0100001114 18 Each
32 2.06 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 6 Module (200 mm X 75 mm)\n BI01010001010000000000000515BI0100001114 18 Each
33 2.07 Supplying, Installation, Testing and Commisioning of recessed Mounted ultraslim LED fixture flat panel 2' x 2' made of extruded aluminium frame with high efficient LEDs & glare free opal diffuser min 36 watt complete in false ceiling with driver (constant current and constant voltage) complete in every way as required. (Halonix CAT Ref. No. HLFPU22-02-36-WW or its equivalent) BI01010001010000000000000515BI0100001114 8 Each
34 2.08 Supplying and Fixing PVC Casing & capping of 25 MM for circuit wiring as per direction of Engineer -in -Charge. BI01010001010000000000000515BI0100001114 20 Meter
35 2.09 Supplying, Installation, Testing and Commisioning of recessed mounted circular LED downlight fixture, min 15 watt in false ceiling complete with driver (constant current and constant voltage) complete in every way as required. (Philips Part no. 919215850698 or approved equivalent) BI01010001010000000000000515BI0100001114 4 Each